testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
-source $rootdir/scripts/autotest_common.sh
+source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
-rpc_py="python $rootdir/scripts/rpc.py"
+rpc_py="$rootdir/scripts/rpc.py"
set -e
-if ! rdma_nic_available; then
- echo "no NIC for nvmf test"
- exit 0
+RDMA_IP_LIST=$(get_available_rdma_ips)
+NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
+if [ -z $NVMF_FIRST_TARGET_IP ]; then
+ echo "no NIC for nvmf test"
+ exit 0
fi
timing_enter aer
+timing_enter start_nvmf_tgt
-# Start up the NVMf target in another process
-$rootdir/app/nvmf_tgt/nvmf_tgt -c $testdir/../nvmf.conf -m 0x2 -p 1 -s 512 &
+$NVMF_APP -m 0xF &
nvmfpid=$!
-trap "killprocess $nvmfpid; exit 1" SIGINT SIGTERM EXIT
+trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; exit 1" SIGINT SIGTERM EXIT
-waitforlisten $nvmfpid ${RPC_PORT}
+waitforlisten $nvmfpid
+$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
+timing_exit start_nvmf_tgt
-$rpc_py construct_nvmf_subsystem Direct nqn.2016-06.io.spdk:cnode1 'transport:RDMA traddr:192.168.100.8 trsvcid:4420' '' -p "*"
+modprobe -v nvme-rdma
-$rootdir/test/lib/nvme/aer/aer -r "\
+$rpc_py construct_malloc_bdev 64 512 --name Malloc0
+$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 -m 2
+$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
+$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
+
+$rpc_py get_nvmf_subsystems
+
+# TODO: this aer test tries to invoke an AER completion by setting the temperature
+#threshold to a very low value. This does not work with emulated controllers
+#though so currently the test is disabled.
+
+#$rootdir/test/nvme/aer/aer -r "\
+# trtype:RDMA \
+# adrfam:IPv4 \
+# traddr:$NVMF_FIRST_TARGET_IP \
+# trsvcid:$NVMF_PORT \
+# subnqn:nqn.2014-08.org.nvmexpress.discovery"
+
+# Namespace Attribute Notice Tests
+$rootdir/test/nvme/aer/aer -r "\
trtype:RDMA \
adrfam:IPv4 \
traddr:$NVMF_FIRST_TARGET_IP \
trsvcid:$NVMF_PORT \
- subnqn:nqn.2014-08.org.nvmexpress.discovery"
-sync
+ subnqn:nqn.2016-06.io.spdk:cnode1" -n 2 &
+aerpid=$!
+
+# Waiting for aer start to work
+sleep 5
+
+# Add a new namespace
+$rpc_py construct_malloc_bdev 64 4096 --name Malloc1
+$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc1 -n 2
+$rpc_py get_nvmf_subsystems
+
+wait $aerpid
+
+$rpc_py delete_malloc_bdev Malloc0
+$rpc_py delete_malloc_bdev Malloc1
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
trap - SIGINT SIGTERM EXIT
+nvmfcleanup
killprocess $nvmfpid
timing_exit aer