## @file\r
# Generate AutoGen.h, AutoGen.c and *.depex files\r
#\r
-# Copyright (c) 2007 - 2015, Intel Corporation. All rights reserved.<BR>\r
+# Copyright (c) 2007 - 2016, Intel Corporation. All rights reserved.<BR>\r
# This program and the accompanying materials\r
# are licensed and made available under the terms and conditions of the BSD License\r
# which accompanies this distribution. The full text of the license may be found at\r
GlobalData.gFdfParser = Fdf\r
GlobalData.gAutoGenPhase = False\r
PcdSet = Fdf.Profile.PcdDict\r
+ if Fdf.CurrentFdName and Fdf.CurrentFdName in Fdf.Profile.FdDict:\r
+ FdDict = Fdf.Profile.FdDict[Fdf.CurrentFdName]\r
+ for FdRegion in FdDict.RegionList:\r
+ if str(FdRegion.RegionType) is 'FILE' and self.Platform.VpdToolGuid in str(FdRegion.RegionDataList):\r
+ if int(FdRegion.Offset) % 8 != 0:\r
+ EdkLogger.error("build", FORMAT_INVALID, 'The VPD Base Address %s must be 8-byte aligned.' % (FdRegion.Offset))\r
ModuleList = Fdf.Profile.InfList\r
self.FdfProfile = Fdf.Profile\r
for fvname in self.FvTargetList:\r
DecPcds = {}\r
DecPcdsKey = set()\r
PGen = PlatformAutoGen(self, self.MetaFile, Target, Toolchain, Arch)\r
+ if GlobalData.BuildOptionPcd:\r
+ for i, pcd in enumerate(GlobalData.BuildOptionPcd):\r
+ (pcdname, pcdvalue) = pcd.split('=')\r
+ if not pcdvalue:\r
+ EdkLogger.error('build', AUTOGEN_ERROR, "No Value specified for the PCD %s." % (pcdname))\r
+ if '.' in pcdname:\r
+ (TokenSpaceGuidCName, TokenCName) = pcdname.split('.')\r
+ HasTokenSpace = True\r
+ else:\r
+ TokenCName = pcdname\r
+ TokenSpaceGuidCName = ''\r
+ HasTokenSpace = False\r
+ TokenSpaceGuidCNameList = []\r
+ FoundFlag = False\r
+ PcdDatumType = ''\r
+ NewValue = ''\r
+ for package in PGen.PackageList:\r
+ for key in package.Pcds:\r
+ PcdItem = package.Pcds[key]\r
+ if HasTokenSpace:\r
+ if (PcdItem.TokenCName, PcdItem.TokenSpaceGuidCName) == (TokenCName, TokenSpaceGuidCName):\r
+ PcdDatumType = PcdItem.DatumType\r
+ NewValue = self._BuildOptionPcdValueFormat(TokenSpaceGuidCName, TokenCName, PcdDatumType, pcdvalue)\r
+ FoundFlag = True\r
+ else:\r
+ if PcdItem.TokenCName == TokenCName:\r
+ if not PcdItem.TokenSpaceGuidCName in TokenSpaceGuidCNameList:\r
+ if len (TokenSpaceGuidCNameList) < 1:\r
+ TokenSpaceGuidCNameList.append(PcdItem.TokenSpaceGuidCName)\r
+ PcdDatumType = PcdItem.DatumType\r
+ TokenSpaceGuidCName = PcdItem.TokenSpaceGuidCName\r
+ NewValue = self._BuildOptionPcdValueFormat(TokenSpaceGuidCName, TokenCName, PcdDatumType, pcdvalue)\r
+ FoundFlag = True\r
+ else:\r
+ EdkLogger.error(\r
+ 'build',\r
+ AUTOGEN_ERROR,\r
+ "The Pcd %s is found under multiple different TokenSpaceGuid: %s and %s." % (TokenCName, PcdItem.TokenSpaceGuidCName, TokenSpaceGuidCNameList[0])\r
+ )\r
+\r
+ GlobalData.BuildOptionPcd[i] = (TokenSpaceGuidCName, TokenCName, NewValue)\r
+\r
+ if not FoundFlag:\r
+ if HasTokenSpace:\r
+ EdkLogger.error('build', AUTOGEN_ERROR, "The Pcd %s.%s is not found in the DEC file." % (TokenSpaceGuidCName, TokenCName))\r
+ else:\r
+ EdkLogger.error('build', AUTOGEN_ERROR, "The Pcd %s is not found in the DEC file." % (TokenCName))\r
+\r
+ for BuildData in PGen.BuildDatabase._CACHE_.values():\r
+ if BuildData.Arch != Arch:\r
+ continue\r
+ if BuildData.MetaFile.Ext == '.dec':\r
+ continue\r
+ for key in BuildData.Pcds:\r
+ PcdItem = BuildData.Pcds[key]\r
+ if (TokenSpaceGuidCName, TokenCName) == (PcdItem.TokenSpaceGuidCName, PcdItem.TokenCName):\r
+ PcdItem.DefaultValue = NewValue\r
+\r
+ if (TokenCName, TokenSpaceGuidCName) in PcdSet:\r
+ PcdSet[(TokenCName, TokenSpaceGuidCName)] = NewValue\r
+\r
#Collect package set information from INF of FDF\r
PkgSet = set()\r
for Inf in ModuleList:\r
\r
return True\r
\r
+ def _BuildOptionPcdValueFormat(self, TokenSpaceGuidCName, TokenCName, PcdDatumType, Value):\r
+ if PcdDatumType == 'VOID*':\r
+ if Value.startswith('L'):\r
+ if not Value[1]:\r
+ EdkLogger.error('build', OPTION_VALUE_INVALID, 'For Void* type PCD, when specify the Value in the command line, please use the following format: "string", L"string", B"{...}"')\r
+ Value = Value[0] + '"' + Value[1:] + '"'\r
+ elif Value.startswith('B'):\r
+ if not Value[1]:\r
+ EdkLogger.error('build', OPTION_VALUE_INVALID, 'For Void* type PCD, when specify the Value in the command line, please use the following format: "string", L"string", B"{...}"')\r
+ Value = Value[1:]\r
+ else:\r
+ if not Value[0]:\r
+ EdkLogger.error('build', OPTION_VALUE_INVALID, 'For Void* type PCD, when specify the Value in the command line, please use the following format: "string", L"string", B"{...}"')\r
+ Value = '"' + Value + '"'\r
+\r
+ IsValid, Cause = CheckPcdDatum(PcdDatumType, Value)\r
+ if not IsValid:\r
+ EdkLogger.error('build', FORMAT_INVALID, Cause, ExtraData="%s.%s" % (TokenSpaceGuidCName, TokenCName))\r
+ if PcdDatumType == 'BOOLEAN':\r
+ Value = Value.upper()\r
+ if Value == 'TRUE' or Value == '1':\r
+ Value = '1'\r
+ elif Value == 'FALSE' or Value == '0':\r
+ Value = '0'\r
+ return Value\r
+\r
## _CheckDuplicateInFV() method\r
#\r
# Check whether there is duplicate modules/files exist in FV section. \r
# This interface should be invoked explicitly when platform action is created.\r
#\r
def CollectPlatformDynamicPcds(self):\r
+ # Override the platform Pcd's value by build option\r
+ if GlobalData.BuildOptionPcd:\r
+ for key in self.Platform.Pcds:\r
+ PlatformPcd = self.Platform.Pcds[key]\r
+ for PcdItem in GlobalData.BuildOptionPcd:\r
+ if (PlatformPcd.TokenSpaceGuidCName, PlatformPcd.TokenCName) == (PcdItem[0], PcdItem[1]):\r
+ PlatformPcd.DefaultValue = PcdItem[2]\r
+ if PlatformPcd.SkuInfoList:\r
+ Sku = PlatformPcd.SkuInfoList[PlatformPcd.SkuInfoList.keys()[0]]\r
+ Sku.DefaultValue = PcdItem[2]\r
+ break\r
+\r
# for gathering error information\r
NoDatumTypePcdList = set()\r
PcdNotInDb = []\r
Pcd = VpdPcdDict[PcdKey]\r
for (SkuName,Sku) in Pcd.SkuInfoList.items():\r
Sku.VpdOffset = Sku.VpdOffset.strip()\r
+ PcdValue = Sku.DefaultValue\r
+ if PcdValue == "":\r
+ PcdValue = Pcd.DefaultValue\r
+ if Sku.VpdOffset != '*':\r
+ if PcdValue.startswith("{"):\r
+ Alignment = 8\r
+ elif PcdValue.startswith("L"):\r
+ Alignment = 2\r
+ else:\r
+ Alignment = 1\r
+ try:\r
+ VpdOffset = int(Sku.VpdOffset)\r
+ except:\r
+ try:\r
+ VpdOffset = int(Sku.VpdOffset, 16)\r
+ except:\r
+ EdkLogger.error("build", FORMAT_INVALID, "Invalid offset value %s for PCD %s.%s." % (Sku.VpdOffset, Pcd.TokenSpaceGuidCName, Pcd.TokenCName))\r
+ if VpdOffset % Alignment != 0:\r
+ if PcdValue.startswith("{"):\r
+ EdkLogger.warn("build", "The offset value of PCD %s.%s is not 8-byte aligned!" %(Pcd.TokenSpaceGuidCName, Pcd.TokenCName), File=self.MetaFile)\r
+ else:\r
+ EdkLogger.error("build", FORMAT_INVALID, 'The offset value of PCD %s.%s should be %s-byte aligned.' % (Pcd.TokenSpaceGuidCName, Pcd.TokenCName, Alignment))\r
VpdFile.Add(Pcd, Sku.VpdOffset)\r
# if the offset of a VPD is *, then it need to be fixed up by third party tool.\r
if not NeedProcessVpdMapFile and Sku.VpdOffset == "*":\r
# Sku = DscPcdEntry.SkuInfoList[DscPcdEntry.SkuInfoList.keys()[0]]\r
Sku.VpdOffset = Sku.VpdOffset.strip()\r
PcdValue = Sku.DefaultValue\r
+ if PcdValue == "":\r
+ PcdValue = DscPcdEntry.DefaultValue\r
+ if Sku.VpdOffset != '*':\r
+ if PcdValue.startswith("{"):\r
+ Alignment = 8\r
+ elif PcdValue.startswith("L"):\r
+ Alignment = 2\r
+ else:\r
+ Alignment = 1\r
+ try:\r
+ VpdOffset = int(Sku.VpdOffset)\r
+ except:\r
+ try:\r
+ VpdOffset = int(Sku.VpdOffset, 16)\r
+ except:\r
+ EdkLogger.error("build", FORMAT_INVALID, "Invalid offset value %s for PCD %s.%s." % (Sku.VpdOffset, DscPcdEntry.TokenSpaceGuidCName, DscPcdEntry.TokenCName))\r
+ if VpdOffset % Alignment != 0:\r
+ if PcdValue.startswith("{"):\r
+ EdkLogger.warn("build", "The offset value of PCD %s.%s is not 8-byte aligned!" %(DscPcdEntry.TokenSpaceGuidCName, DscPcdEntry.TokenCName), File=self.MetaFile)\r
+ else:\r
+ EdkLogger.error("build", FORMAT_INVALID, 'The offset value of PCD %s.%s should be %s-byte aligned.' % (DscPcdEntry.TokenSpaceGuidCName, DscPcdEntry.TokenCName, Alignment))\r
VpdFile.Add(DscPcdEntry, Sku.VpdOffset)\r
if not NeedProcessVpdMapFile and Sku.VpdOffset == "*":\r
NeedProcessVpdMapFile = True \r
"Fail to get FLASH_DEFINITION definition in DSC file %s which is required when DSC contains VPD PCD." % str(self.Platform.MetaFile))\r
\r
if VpdFile.GetCount() != 0:\r
- DscTimeStamp = self.Platform.MetaFile.TimeStamp\r
FvPath = os.path.join(self.BuildDir, "FV")\r
if not os.path.exists(FvPath):\r
try:\r
except:\r
EdkLogger.error("build", FILE_WRITE_FAILURE, "Fail to create FV folder under %s" % self.BuildDir)\r
\r
-\r
VpdFilePath = os.path.join(FvPath, "%s.txt" % self.Platform.VpdToolGuid)\r
\r
-\r
- if not os.path.exists(VpdFilePath) or os.path.getmtime(VpdFilePath) < DscTimeStamp:\r
- VpdFile.Write(VpdFilePath)\r
-\r
+ if VpdFile.Write(VpdFilePath):\r
# retrieve BPDG tool's path from tool_def.txt according to VPD_TOOL_GUID defined in DSC file.\r
BPDGToolName = None\r
for ToolDef in self.ToolDefinition.values():\r
self._MakeFileDir = None\r
\r
self._IncludePathList = None\r
+ self._IncludePathLength = 0\r
self._AutoGenFileList = None\r
self._UnicodeFileList = None\r
self._SourceFileList = None\r
self._Macro["MODULE_BUILD_DIR" ] = self.BuildDir\r
self._Macro["OUTPUT_DIR" ] = self.OutputDir\r
self._Macro["DEBUG_DIR" ] = self.DebugDir\r
+ self._Macro["DEST_DIR_OUTPUT" ] = self.OutputDir\r
+ self._Macro["DEST_DIR_DEBUG" ] = self.DebugDir\r
+ self._Macro["PLATFORM_NAME" ] = self.PlatformInfo.Name\r
+ self._Macro["PLATFORM_GUID" ] = self.PlatformInfo.Guid\r
+ self._Macro["PLATFORM_VERSION" ] = self.PlatformInfo.Version\r
+ self._Macro["PLATFORM_RELATIVE_DIR" ] = self.PlatformInfo.SourceDir\r
+ self._Macro["PLATFORM_DIR" ] = mws.join(self.WorkspaceDir, self.PlatformInfo.SourceDir)\r
+ self._Macro["PLATFORM_OUTPUT_DIR" ] = self.PlatformInfo.OutputDir\r
return self._Macro\r
\r
## Return the module build data object\r
if F.Dir not in self.IncludePathList and self.AutoGenVersion >= 0x00010005:\r
self.IncludePathList.insert(0, F.Dir)\r
self._SourceFileList.append(F)\r
+\r
+ self._MatchBuildRuleOrder(self._SourceFileList)\r
+\r
+ for F in self._SourceFileList:\r
self._ApplyBuildRule(F, TAB_UNKNOWN_FILE)\r
return self._SourceFileList\r
\r
+ def _MatchBuildRuleOrder(self, FileList):\r
+ Order_Dict = {}\r
+ self._GetModuleBuildOption()\r
+ for SingleFile in FileList:\r
+ if self.BuildRuleOrder and SingleFile.Ext in self.BuildRuleOrder and SingleFile.Ext in self.BuildRules:\r
+ key = SingleFile.Path.split(SingleFile.Ext)[0]\r
+ if key in Order_Dict:\r
+ Order_Dict[key].append(SingleFile.Ext)\r
+ else:\r
+ Order_Dict[key] = [SingleFile.Ext]\r
+\r
+ RemoveList = []\r
+ for F in Order_Dict:\r
+ if len(Order_Dict[F]) > 1:\r
+ Order_Dict[F].sort(key=lambda i: self.BuildRuleOrder.index(i))\r
+ for Ext in Order_Dict[F][1:]:\r
+ RemoveList.append(F + Ext)\r
+ \r
+ for item in RemoveList:\r
+ FileList.remove(item)\r
+\r
+ return FileList\r
+\r
## Return the list of unicode files\r
def _GetUnicodeFileList(self):\r
if self._UnicodeFileList == None:\r
self._IncludePathList.append(str(Inc))\r
return self._IncludePathList\r
\r
+ def _GetIncludePathLength(self):\r
+ self._IncludePathLength = 0\r
+ if self._IncludePathList:\r
+ for inc in self._IncludePathList:\r
+ self._IncludePathLength += len(' ' + inc)\r
+ return self._IncludePathLength\r
+\r
## Get HII EX PCDs which maybe used by VFR\r
#\r
# efivarstore used by VFR may relate with HII EX PCDs\r
CustomMakefile = property(_GetCustomMakefile)\r
\r
IncludePathList = property(_GetIncludePathList)\r
+ IncludePathLength = property(_GetIncludePathLength)\r
AutoGenFileList = property(_GetAutoGenFileList)\r
UnicodeFileList = property(_GetUnicodeFileList)\r
SourceFileList = property(_GetSourceFileList)\r