]> git.proxmox.com Git - pve-docs.git/blame - pve-installation.adoc
followup: s/buster/Buster/
[pve-docs.git] / pve-installation.adoc
CommitLineData
32caab0e
AL
1Installing {pve}
2================
194d2f29 3ifndef::manvolnum[]
5f09af76 4:pve-toplevel:
194d2f29
DM
5endif::manvolnum[]
6ifdef::wiki[]
cb84ed18 7:title: Installation
5f09af76
DM
8endif::wiki[]
9
32caab0e 10{pve} is based on Debian. This is why the install disk images (ISO files)
e5d3a235 11provided by Proxmox include a complete Debian system (Debian 10 Buster for
32caab0e 12{pve} version 6.x) as well as all necessary {pve} packages.
2d99ce9b 13
32caab0e
AL
14The installer will guide through the setup, allowing you to partition the local
15disk(s), apply basic system configurations (e.g. timezone, language, network)
16and install all required packages. This process should not take more than a few
17minutes. Installing with the provided ISO is the recommended method for new and
18existing users.
d91f8c1e 19
32caab0e
AL
20Alternatively, {pve} can be installed on top of an existing Debian system. This
21option is only recommended for advanced users because detailed knowledge about
22{pve} is required.
d91f8c1e 23
bc1c71d4
DM
24ifndef::wiki[]
25
26include::pve-system-requirements.adoc[]
27
28endif::wiki[]
29
5eba0743 30
2c6fed66
TM
31Using the {pve} Installer
32-------------------------
d91f8c1e 33
32caab0e 34Download the installer ISO at {website}en/downloads. It includes the following:
115aef16 35
e69c1847
DM
36* Complete operating system (Debian Linux, 64-bit)
37
2c6fed66 38* The {pve} installer, which partitions the local disk(s) with ext4,
2d99ce9b 39 ext3, xfs or ZFS and installs the operating system.
e69c1847 40
32caab0e 41* {pve} kernel (Linux) with KVM and LXC support
e69c1847
DM
42
43* Complete toolset for administering virtual machines, containers and
44 all necessary resources
45
32caab0e 46* Web-based management interface
115aef16 47
32caab0e
AL
48NOTE: All existing data on the server will be removed during the installation
49process.
078924cd 50
32caab0e 51Please insert the installation media (e.g. USB flash drive, CD-ROM) and boot
2c6fed66
TM
52from it.
53
1ff5e4e8 54[thumbnail="screenshot/pve-grub-menu.png"]
2d99ce9b 55
32caab0e
AL
56After choosing the correct entry (e.g. Boot from USB) the {pve} menu will be
57displayed and one of the following options can be selected:
d91f8c1e 58
32caab0e 59Install {pve}::
d91f8c1e 60
32caab0e 61Starts the normal installation.
d91f8c1e 62
32caab0e
AL
63TIP: It's possible to use the installation wizard with a keyboard only. Buttons
64can be clicked by pressing the `ALT` key combined with the underlined character
65from the respective button. For example, `ALT + N` to press a `Next` button.
1a5554fc 66
32caab0e 67Install {pve} (Debug mode)::
d91f8c1e 68
32caab0e
AL
69Starts the installation in debug mode. A console will be opened at several
70installation steps. This helps to debug the situation if something goes wrong.
71To exit a debug console, press `CTRL-D`. This options is primarily for
72developers and not intended for general use.
d91f8c1e
DM
73
74Rescue Boot::
75
32caab0e
AL
76With this option you can boot an existing installation. It searches all attached
77hard disks. If it finds an existing installation, it boots directly into that
78disk using the Linux kernel from the ISO. This can be useful if there are
79problems with the boot block (grub) or the BIOS is unable to read the boot block
80from the disk.
d91f8c1e
DM
81
82Test Memory::
83
32caab0e
AL
84Runs `memtest86+`. This is useful to check if the memory is functional and free
85of errors.
d91f8c1e 86
1ff5e4e8 87[thumbnail="screenshot/pve-select-target-disk.png"]
2d99ce9b 88
32caab0e
AL
89After selecting *Install {pve}* and accepting the EULA, the prompt to select the
90target hard disk(s) will appear. The `Options` button opens the dialog to select
91the target file system.
d91f8c1e 92
32caab0e
AL
93The default file system is `ext4`. The Logical Volume Manager (LVM) is used when
94`ext3`, `ext4` or `xfs` ist selected. Additional options to restrict LVM space
95can be set (see <<advanced_lvm_options,below>>).
96
97{pve} can be installed on ZFS. As ZFS offers several software RAID levels, this
98is an option for systems that don't have a hardware RAID controller. The target
99disks must be selected in the `Options` dialog. More ZFS specific settings can
100be changed under `Advanced Options` (see <<advanced_zfs_options,below>>).
101
102WARNING: ZFS on top of any hardware RAID is not supported and can result in data
103loss.
d91f8c1e 104
1ff5e4e8 105[thumbnail="screenshot/pve-select-location.png", float="left"]
2d99ce9b 106
32caab0e
AL
107The next page asks for basic configuration options like the location, the time
108zone, and keyboard layout. The location is used to select a download server
109close by to speed up updates. The installer usually auto-detects these settings.
110They only need to be changed in the rare case that auto detection fails or a
111different keyboard layout should be used.
2d99ce9b 112
1ff5e4e8 113[thumbnail="screenshot/pve-set-password.png"]
2d99ce9b 114
32caab0e
AL
115Next the password of the superuser (root) and an email address needs to be
116specified. The password must consist of at least 5 characters. It's highly
117recommended to use a stronger password. Some guidelines are:
2d99ce9b
DM
118
119- Use a minimum password length of 12 to 14 characters.
120
32caab0e 121- Include lowercase and uppercase alphabetic characters, numbers, and symbols.
2d99ce9b 122
32caab0e
AL
123- Avoid character repetition, keyboard patterns, common dictionary words,
124 letter or number sequences, usernames, relative or pet names, romantic links
125 (current or past), and biographical information (for example ID numbers,
126 ancestors' names or dates).
2d99ce9b 127
32caab0e
AL
128The email address is used to send notifications to the system administrator.
129For example:
2d99ce9b
DM
130
131- Information about available package updates.
132
133- Error messages from periodic CRON jobs.
134
7df6cb98
TL
135[thumbnail="screenshot/pve-setup-network.png"]
136
32caab0e
AL
137The last step is the network configuration. Please note that during installation
138you can either use an IPv4 or IPv6 address, but not both. To configure a dual
139stack node, add additional IP addresses after the installation.
d91f8c1e 140
1ff5e4e8 141[thumbnail="screenshot/pve-installation.png", float="left"]
2d99ce9b 142
32caab0e
AL
143The next step shows a summary of the previously selected options. Re-check every
144setting and use the `Previous` button if a setting needs to be changed. To
145accept, press `Install`. The installation starts to format disks and copies
146packages to the target. Please wait until this step has finished; then remove
147the installation medium and restart your system.
d91f8c1e 148
7df6cb98
TL
149[thumbnail="screenshot/pve-install-summary.png"]
150
151If the installation failed check out specific errors on the second TTY
32caab0e 152(`CTRL + ALT + F2'), ensure that the systems meets the
7df6cb98 153xref:install_minimal_requirements[minimum requirements]. If the installation
32caab0e 154is still not working look at the xref:getting_help[how to get help chapter].
7df6cb98 155
32caab0e
AL
156Further configuration is done via the Proxmox web interface. Point your browser
157to the IP address given during installation (https://youripaddress:8006).
fe6c04d5 158
32caab0e
AL
159NOTE: Default login is "root" (realm 'PAM') and the root password is defined
160during the installation process.
d91f8c1e
DM
161
162[[advanced_lvm_options]]
5eba0743 163Advanced LVM Configuration Options
6b5fc47b 164~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
d91f8c1e 165
32caab0e
AL
166The installer creates a Volume Group (VG) called `pve`, and additional Logical
167Volumes (LVs) called `root`, `data`, and `swap`. To control the size of these
168volumes use:
d91f8c1e
DM
169
170`hdsize`::
171
32caab0e
AL
172Defines the total hard disk size to be used. This way you can reserve free space
173on the hard disk for further partitioning (for example for an additional PV and
174VG on the same hard disk that can be used for LVM storage).
d91f8c1e
DM
175
176`swapsize`::
177
fa281da6
TL
178Defines the size of the `swap` volume. The default is the size of the
179installed memory, minimum 4 GB and maximum 8 GB. The resulting value cannot
180be greater than `hdsize/8`.
e8fe2b1b
FG
181+
182NOTE: If set to `0`, no `swap` volume will be created.
d91f8c1e
DM
183
184`maxroot`::
185
fa281da6
TL
186Defines the maximum size of the `root` volume, which stores the operation
187system. The maximum limit of the `root` volume size is `hdsize/4`.
d91f8c1e
DM
188
189`maxvz`::
190
fa281da6
TL
191Defines the maximum size of the `data` volume. The actual size of the `data`
192volume is:
193+
194`datasize = hdsize - rootsize - swapsize - minfree`
195+
196Where `datasize` cannot be bigger than `maxvz`.
e8fe2b1b 197+
32caab0e
AL
198NOTE: In case of LVM thin, the `data` pool will only be created if `datasize` is
199bigger than 4GB.
e8fe2b1b
FG
200+
201NOTE: If set to `0`, no `data` volume will be created and the storage
202configuration will be adapted accordingly.
d91f8c1e
DM
203
204`minfree`::
205
32caab0e
AL
206Defines the amount of free space left in the LVM volume group `pve`. With more
207than 128GB storage available the default is 16GB, else `hdsize/8` will be used.
d91f8c1e 208+
32caab0e
AL
209NOTE: LVM requires free space in the VG for snapshot creation (not required for
210lvmthin snapshots).
d91f8c1e 211
71280de0
SI
212[[advanced_zfs_options]]
213Advanced ZFS Configuration Options
214~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
32caab0e
AL
215The installer creates the ZFS pool `rpool`. No swap space is created but you can
216reserve some unpartitioned space on the install disks for swap. You can also
217create a swap zvol after the installation, altough this can lead to problems.
71280de0
SI
218(see <<zfs_swap,ZFS swap notes>>).
219
220`ashift`::
221
32caab0e
AL
222Defines the `ashift` value for the created pool. The `ashift` needs to be set at
223least to the sector-size of the underlying disks (2 to the power of `ashift` is
224the sector-size), or any disk which might be put in the pool (for example the
225replacement of a defective disk).
71280de0
SI
226
227`compress`::
228
229Defines whether compression is enabled for `rpool`.
230
231`checksum`::
232
233Defines which checksumming algorithm should be used for `rpool`.
234
235`copies`::
236
237Defines the `copies` parameter for `rpool`. Check the `zfs(8)` manpage for the
238semantics, and why this does not replace redundancy on disk-level.
239
240`hdsize`::
241
32caab0e
AL
242Defines the total hard disk size to be used. This is useful to save free space
243on the hard disk(s) for further partitioning (for exmaple to create a
244swap-partition). `hdsize` is only honored for bootable disks, that is only the
245first disk or mirror for RAID0, RAID1 or RAID10, and all disks in RAID-Z[123].
71280de0 246
d91f8c1e
DM
247
248ZFS Performance Tips
6b5fc47b 249~~~~~~~~~~~~~~~~~~~~
d91f8c1e 250
32caab0e
AL
251ZFS works best with a lot of memory. If you intend to use ZFS make sure to have
252enough RAM available for it. A good calculation is 4GB plus 1GB RAM for each TB
cdf58596 253RAW disk space.
d91f8c1e 254
32caab0e
AL
255ZFS can use a dedicated drive as write cache, called the ZFS Intent Log (ZIL).
256Use a fast drive (SSD) for it. It can be added after installation with the
257following command:
d91f8c1e 258
32caab0e
AL
259----
260# zpool add <pool-name> log </dev/path_to_fast_ssd>
261----
078924cd
DM
262
263ifdef::wiki[]
264
5c6cf7ac
DM
265link:/wiki/Install_from_USB_Stick[Install from USB Stick]
266---------------------------------------------------------
267
d7f5c1f7
TL
268link:/wiki/Install_Proxmox_VE_on_Debian_Buster[Install Proxmox VE on Debian Buster]
269-----------------------------------------------------------------------------------
2c6fed66 270
078924cd
DM
271endif::wiki[]
272
273ifndef::wiki[]
274
2c6fed66
TM
275include::pve-usbstick.adoc[]
276
078924cd 277Install {pve} on Debian
6b5fc47b 278-----------------------
078924cd 279
32caab0e
AL
280{pve} ships as a set of Debian packages and can be installed on to of a standard
281Debian installation.
282xref:sysadmin_package_repositories[After configuring the repositories] you need
283to run the following commands:
078924cd 284
078924cd 285----
32caab0e
AL
286# apt-get update
287# apt-get install proxmox-ve
078924cd
DM
288----
289
32caab0e
AL
290Installing on top of an existing Debian installation looks easy, but it presumes
291that the base system has been installed correctly and that you know how you want
292to configure and use the local storage. You also need to configure the network
293manually.
115aef16 294
32caab0e 295In general, this is not trivial, especially when LVM or ZFS is used.
115aef16 296
32caab0e 297A detailed step by step how-to can be found on the
acb3e8d7 298{webwiki-url}Install_Proxmox_VE_on_Debian_Stretch[wiki].
078924cd 299
078924cd 300
5c6cf7ac 301endif::wiki[]
078924cd 302
078924cd
DM
303ifdef::wiki[]
304
305Video Tutorials
6b5fc47b 306---------------
078924cd
DM
307
308* List of all official tutorials on our
32caab0e 309 http://www.youtube.com/proxmoxve[{pve} YouTube Channel]
078924cd
DM
310
311* Tutorials in Spanish language on
312 http://www.youtube.com/playlist?list=PLUULBIhA5QDBdNf1pcTZ5UXhek63Fij8z[ITexperts.es
313 YouTube Play List]
314
315
316See Also
6b5fc47b 317--------
078924cd 318
bc1c71d4
DM
319* link:/wiki/System_Requirements[System Requirements]
320
078924cd
DM
321* link:/wiki/Package_Repositories[Package Repositories]
322
323* link:/wiki/Host_System_Administration[Host System Administration]
324
325* link:/wiki/Network_Configuration[Network Configuration]
326
e723066c
DM
327* link:/wiki/Installation:_Tips_and_Tricks[Installation: Tips and Tricks]
328
078924cd 329endif::wiki[]