]> git.proxmox.com Git - pve-docs.git/blame_incremental - qm.conf.5-opts.adoc
backup: clarify that CLI means FS-level and highlight retention-note
[pve-docs.git] / qm.conf.5-opts.adoc
... / ...
CommitLineData
1`acpi`: `<boolean>` ('default =' `1`)::
2
3Enable/disable ACPI.
4
5`agent`: `[enabled=]<1|0> [,fstrim_cloned_disks=<1|0>] [,type=<virtio|isa>]` ::
6
7Enable/disable communication with the Qemu Guest Agent and its properties.
8
9`enabled`=`<boolean>` ('default =' `0`);;
10
11Enable/disable communication with a Qemu Guest Agent (QGA) running in the VM.
12
13`fstrim_cloned_disks`=`<boolean>` ('default =' `0`);;
14
15Run fstrim after moving a disk or migrating the VM.
16
17`type`=`<isa | virtio>` ('default =' `virtio`);;
18
19Select the agent type
20
21`arch`: `<aarch64 | x86_64>` ::
22
23Virtual processor architecture. Defaults to the host.
24
25`args`: `<string>` ::
26
27Arbitrary arguments passed to kvm, for example:
28+
29args: -no-reboot -no-hpet
30+
31NOTE: this option is for experts only.
32
33`audio0`: `device=<ich9-intel-hda|intel-hda|AC97> [,driver=<spice|none>]` ::
34
35Configure a audio device, useful in combination with QXL/Spice.
36
37`device`=`<AC97 | ich9-intel-hda | intel-hda>` ;;
38
39Configure an audio device.
40
41`driver`=`<none | spice>` ('default =' `spice`);;
42
43Driver backend for the audio device.
44
45`autostart`: `<boolean>` ('default =' `0`)::
46
47Automatic restart after crash (currently ignored).
48
49`balloon`: `<integer> (0 - N)` ::
50
51Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
52
53`bios`: `<ovmf | seabios>` ('default =' `seabios`)::
54
55Select BIOS implementation.
56
57`boot`: `[[legacy=]<[acdn]{1,4}>] [,order=<device[;device...]>]` ::
58
59Specify guest boot order. Use the 'order=' sub-property as usage with no key or 'legacy=' is deprecated.
60
61`legacy`=`<[acdn]{1,4}>` ('default =' `cdn`);;
62
63Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n). Deprecated, use 'order=' instead.
64
65`order`=`<device[;device...]>` ;;
66
67The guest will attempt to boot from devices in the order they appear here.
68+
69Disks, optical drives and passed-through storage USB devices will be directly
70booted from, NICs will load PXE, and PCIe devices will either behave like disks
71(e.g. NVMe) or load an option ROM (e.g. RAID controller, hardware NIC).
72+
73Note that only devices in this list will be marked as bootable and thus loaded
74by the guest firmware (BIOS/UEFI). If you require multiple disks for booting
75(e.g. software-raid), you need to specify all of them here.
76+
77Overrides the deprecated 'legacy=[acdn]*' value when given.
78
79`bootdisk`: `(ide|sata|scsi|virtio)\d+` ::
80
81Enable booting from specified disk. Deprecated: Use 'boot: order=foo;bar' instead.
82
83`cdrom`: `<volume>` ::
84
85This is an alias for option -ide2
86
87`cicustom`: `[meta=<volume>] [,network=<volume>] [,user=<volume>] [,vendor=<volume>]` ::
88
89cloud-init: Specify custom files to replace the automatically generated ones at start.
90
91`meta`=`<volume>` ;;
92
93Specify a custom file containing all meta data passed to the VM via"
94 ." cloud-init. This is provider specific meaning configdrive2 and nocloud differ.
95
96`network`=`<volume>` ;;
97
98Specify a custom file containing all network data passed to the VM via cloud-init.
99
100`user`=`<volume>` ;;
101
102Specify a custom file containing all user data passed to the VM via cloud-init.
103
104`vendor`=`<volume>` ;;
105
106Specify a custom file containing all vendor data passed to the VM via cloud-init.
107
108`cipassword`: `<string>` ::
109
110cloud-init: Password to assign the user. Using this is generally not recommended. Use ssh keys instead. Also note that older cloud-init versions do not support hashed passwords.
111
112`citype`: `<configdrive2 | nocloud | opennebula>` ::
113
114Specifies the cloud-init configuration format. The default depends on the configured operating system type (`ostype`. We use the `nocloud` format for Linux, and `configdrive2` for windows.
115
116`ciuser`: `<string>` ::
117
118cloud-init: User name to change ssh keys and password for instead of the image's configured default user.
119
120`cores`: `<integer> (1 - N)` ('default =' `1`)::
121
122The number of cores per socket.
123
124`cpu`: `[[cputype=]<string>] [,flags=<+FLAG[;-FLAG...]>] [,hidden=<1|0>] [,hv-vendor-id=<vendor-id>] [,phys-bits=<8-64|host>] [,reported-model=<enum>]` ::
125
126Emulated CPU type.
127
128`cputype`=`<string>` ('default =' `kvm64`);;
129
130Emulated CPU type. Can be default or custom name (custom model names must be prefixed with 'custom-').
131
132`flags`=`<+FLAG[;-FLAG...]>` ;;
133
134List of additional CPU flags separated by ';'. Use '+FLAG' to enable, '-FLAG' to disable a flag. Custom CPU models can specify any flag supported by QEMU/KVM, VM-specific flags must be from the following set for security reasons: pcid, spec-ctrl, ibpb, ssbd, virt-ssbd, amd-ssbd, amd-no-ssb, pdpe1gb, md-clear, hv-tlbflush, hv-evmcs, aes.
135
136`hidden`=`<boolean>` ('default =' `0`);;
137
138Do not identify as a KVM virtual machine.
139
140`hv-vendor-id`=`<vendor-id>` ;;
141
142The Hyper-V vendor ID. Some drivers or programs inside Windows guests need a specific ID.
143
144`phys-bits`=`<8-64|host>` ;;
145
146The physical memory address bits that are reported to the guest OS. Should be smaller or equal to the host's. Set to 'host' to use value from host CPU, but note that doing so will break live migration to CPUs with other values.
147
148`reported-model`=`<486 | Broadwell | Broadwell-IBRS | Broadwell-noTSX | Broadwell-noTSX-IBRS | Cascadelake-Server | Cascadelake-Server-noTSX | Conroe | EPYC | EPYC-IBPB | EPYC-Rome | Haswell | Haswell-IBRS | Haswell-noTSX | Haswell-noTSX-IBRS | Icelake-Client | Icelake-Client-noTSX | Icelake-Server | Icelake-Server-noTSX | IvyBridge | IvyBridge-IBRS | KnightsMill | Nehalem | Nehalem-IBRS | Opteron_G1 | Opteron_G2 | Opteron_G3 | Opteron_G4 | Opteron_G5 | Penryn | SandyBridge | SandyBridge-IBRS | Skylake-Client | Skylake-Client-IBRS | Skylake-Client-noTSX-IBRS | Skylake-Server | Skylake-Server-IBRS | Skylake-Server-noTSX-IBRS | Westmere | Westmere-IBRS | athlon | core2duo | coreduo | host | kvm32 | kvm64 | max | pentium | pentium2 | pentium3 | phenom | qemu32 | qemu64>` ('default =' `kvm64`);;
149
150CPU model and vendor to report to the guest. Must be a QEMU/KVM supported model. Only valid for custom CPU model definitions, default models will always report themselves to the guest OS.
151
152`cpulimit`: `<number> (0 - 128)` ('default =' `0`)::
153
154Limit of CPU usage.
155+
156NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.
157
158`cpuunits`: `<integer> (2 - 262144)` ('default =' `cgroup v1: 1024, cgroup v2: 100`)::
159
160CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.
161
162`description`: `<string>` ::
163
164Description for the VM. Shown in the web-interface VM's summary. This is saved as comment inside the configuration file.
165
166`efidisk0`: `[file=]<volume> [,efitype=<2m|4m>] [,format=<enum>] [,pre-enrolled-keys=<1|0>] [,size=<DiskSize>]` ::
167
168Configure a Disk for storing EFI vars. Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume. Note that SIZE_IN_GiB is ignored here and that the default EFI vars are copied to the volume instead.
169
170`efitype`=`<2m | 4m>` ('default =' `2m`);;
171
172Size and type of the OVMF EFI vars. '4m' is newer and recommended, and required for Secure Boot. For backwards compatibility, '2m' is used if not otherwise specified.
173
174`file`=`<volume>` ;;
175
176The drive's backing volume.
177
178`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
179
180The drive's backing file's data format.
181
182`pre-enrolled-keys`=`<boolean>` ('default =' `0`);;
183
184Use am EFI vars template with distribution-specific and Microsoft Standard keys enrolled, if used with 'efitype=4m'. Note that this will enable Secure Boot by default, though it can still be turned off from within the VM.
185
186`size`=`<DiskSize>` ;;
187
188Disk size. This is purely informational and has no effect.
189
190`freeze`: `<boolean>` ::
191
192Freeze CPU at startup (use 'c' monitor command to start execution).
193
194`hookscript`: `<string>` ::
195
196Script that will be executed during various steps in the vms lifetime.
197
198`hostpci[n]`: `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,legacy-igd=<1|0>] [,mdev=<string>] [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,x-vga=<1|0>]` ::
199
200Map host PCI devices into guest.
201+
202NOTE: This option allows direct access to host hardware. So it is no longer
203possible to migrate such machines - use with special care.
204+
205CAUTION: Experimental! User reported problems with this option.
206
207`host`=`<HOSTPCIID[;HOSTPCIID2...]>` ;;
208
209Host PCI device pass through. The PCI ID of a host's PCI device or a list
210of PCI virtual functions of the host. HOSTPCIID syntax is:
211+
212'bus:dev.func' (hexadecimal numbers)
213+
214You can us the 'lspci' command to list existing PCI devices.
215
216`legacy-igd`=`<boolean>` ('default =' `0`);;
217
218Pass this device in legacy IGD mode, making it the primary and exclusive graphics device in the VM. Requires 'pc-i440fx' machine type and VGA set to 'none'.
219
220`mdev`=`<string>` ;;
221
222The type of mediated device to use.
223An instance of this type will be created on startup of the VM and
224will be cleaned up when the VM stops.
225
226`pcie`=`<boolean>` ('default =' `0`);;
227
228Choose the PCI-express bus (needs the 'q35' machine model).
229
230`rombar`=`<boolean>` ('default =' `1`);;
231
232Specify whether or not the device's ROM will be visible in the guest's memory map.
233
234`romfile`=`<string>` ;;
235
236Custom pci device rom filename (must be located in /usr/share/kvm/).
237
238`x-vga`=`<boolean>` ('default =' `0`);;
239
240Enable vfio-vga device support.
241
242`hotplug`: `<string>` ('default =' `network,disk,usb`)::
243
244Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Using '1' as value is an alias for the default `network,disk,usb`.
245
246`hugepages`: `<1024 | 2 | any>` ::
247
248Enable/disable hugepages memory.
249
250`ide[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
251
252Use volume as IDE hard disk or CD-ROM (n is 0 to 3). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
253
254`aio`=`<io_uring | native | threads>` ;;
255
256AIO type to use.
257
258`backup`=`<boolean>` ;;
259
260Whether the drive should be included when making backups.
261
262`bps`=`<bps>` ;;
263
264Maximum r/w speed in bytes per second.
265
266`bps_max_length`=`<seconds>` ;;
267
268Maximum length of I/O bursts in seconds.
269
270`bps_rd`=`<bps>` ;;
271
272Maximum read speed in bytes per second.
273
274`bps_rd_max_length`=`<seconds>` ;;
275
276Maximum length of read I/O bursts in seconds.
277
278`bps_wr`=`<bps>` ;;
279
280Maximum write speed in bytes per second.
281
282`bps_wr_max_length`=`<seconds>` ;;
283
284Maximum length of write I/O bursts in seconds.
285
286`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
287
288The drive's cache mode
289
290`cyls`=`<integer>` ;;
291
292Force the drive's physical geometry to have a specific cylinder count.
293
294`detect_zeroes`=`<boolean>` ;;
295
296Controls whether to detect and try to optimize writes of zeroes.
297
298`discard`=`<ignore | on>` ;;
299
300Controls whether to pass discard/trim requests to the underlying storage.
301
302`file`=`<volume>` ;;
303
304The drive's backing volume.
305
306`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
307
308The drive's backing file's data format.
309
310`heads`=`<integer>` ;;
311
312Force the drive's physical geometry to have a specific head count.
313
314`iops`=`<iops>` ;;
315
316Maximum r/w I/O in operations per second.
317
318`iops_max`=`<iops>` ;;
319
320Maximum unthrottled r/w I/O pool in operations per second.
321
322`iops_max_length`=`<seconds>` ;;
323
324Maximum length of I/O bursts in seconds.
325
326`iops_rd`=`<iops>` ;;
327
328Maximum read I/O in operations per second.
329
330`iops_rd_max`=`<iops>` ;;
331
332Maximum unthrottled read I/O pool in operations per second.
333
334`iops_rd_max_length`=`<seconds>` ;;
335
336Maximum length of read I/O bursts in seconds.
337
338`iops_wr`=`<iops>` ;;
339
340Maximum write I/O in operations per second.
341
342`iops_wr_max`=`<iops>` ;;
343
344Maximum unthrottled write I/O pool in operations per second.
345
346`iops_wr_max_length`=`<seconds>` ;;
347
348Maximum length of write I/O bursts in seconds.
349
350`mbps`=`<mbps>` ;;
351
352Maximum r/w speed in megabytes per second.
353
354`mbps_max`=`<mbps>` ;;
355
356Maximum unthrottled r/w pool in megabytes per second.
357
358`mbps_rd`=`<mbps>` ;;
359
360Maximum read speed in megabytes per second.
361
362`mbps_rd_max`=`<mbps>` ;;
363
364Maximum unthrottled read pool in megabytes per second.
365
366`mbps_wr`=`<mbps>` ;;
367
368Maximum write speed in megabytes per second.
369
370`mbps_wr_max`=`<mbps>` ;;
371
372Maximum unthrottled write pool in megabytes per second.
373
374`media`=`<cdrom | disk>` ('default =' `disk`);;
375
376The drive's media type.
377
378`model`=`<model>` ;;
379
380The drive's reported model name, url-encoded, up to 40 bytes long.
381
382`replicate`=`<boolean>` ('default =' `1`);;
383
384Whether the drive should considered for replication jobs.
385
386`rerror`=`<ignore | report | stop>` ;;
387
388Read error action.
389
390`secs`=`<integer>` ;;
391
392Force the drive's physical geometry to have a specific sector count.
393
394`serial`=`<serial>` ;;
395
396The drive's reported serial number, url-encoded, up to 20 bytes long.
397
398`shared`=`<boolean>` ('default =' `0`);;
399
400Mark this locally-managed volume as available on all nodes.
401+
402WARNING: This option does not share the volume automatically, it assumes it is shared already!
403
404`size`=`<DiskSize>` ;;
405
406Disk size. This is purely informational and has no effect.
407
408`snapshot`=`<boolean>` ;;
409
410Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
411
412`ssd`=`<boolean>` ;;
413
414Whether to expose this drive as an SSD, rather than a rotational hard disk.
415
416`trans`=`<auto | lba | none>` ;;
417
418Force disk geometry bios translation mode.
419
420`werror`=`<enospc | ignore | report | stop>` ;;
421
422Write error action.
423
424`wwn`=`<wwn>` ;;
425
426The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
427
428`ipconfig[n]`: `[gw=<GatewayIPv4>] [,gw6=<GatewayIPv6>] [,ip=<IPv4Format/CIDR>] [,ip6=<IPv6Format/CIDR>]` ::
429
430cloud-init: Specify IP addresses and gateways for the corresponding interface.
431+
432IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
433+
434The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit
435gateway should be provided.
436For IPv6 the special string 'auto' can be used to use stateless autoconfiguration. This requires
437cloud-init 19.4 or newer.
438+
439If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using
440dhcp on IPv4.
441
442`gw`=`<GatewayIPv4>` ;;
443
444Default gateway for IPv4 traffic.
445+
446NOTE: Requires option(s): `ip`
447
448`gw6`=`<GatewayIPv6>` ;;
449
450Default gateway for IPv6 traffic.
451+
452NOTE: Requires option(s): `ip6`
453
454`ip`=`<IPv4Format/CIDR>` ('default =' `dhcp`);;
455
456IPv4 address in CIDR format.
457
458`ip6`=`<IPv6Format/CIDR>` ('default =' `dhcp`);;
459
460IPv6 address in CIDR format.
461
462`ivshmem`: `size=<integer> [,name=<string>]` ::
463
464Inter-VM shared memory. Useful for direct communication between VMs, or to the host.
465
466`name`=`<string>` ;;
467
468The name of the file. Will be prefixed with 'pve-shm-'. Default is the VMID. Will be deleted when the VM is stopped.
469
470`size`=`<integer> (1 - N)` ;;
471
472The size of the file in MB.
473
474`keephugepages`: `<boolean>` ('default =' `0`)::
475
476Use together with hugepages. If enabled, hugepages will not not be deleted after VM shutdown and can be used for subsequent starts.
477
478`keyboard`: `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ::
479
480Keyboard layout for VNC server. The default is read from the'/etc/pve/datacenter.cfg' configuration file. It should not be necessary to set it.
481
482`kvm`: `<boolean>` ('default =' `1`)::
483
484Enable/disable KVM hardware virtualization.
485
486`localtime`: `<boolean>` ::
487
488Set the real time clock (RTC) to local time. This is enabled by default if the `ostype` indicates a Microsoft Windows OS.
489
490`lock`: `<backup | clone | create | migrate | rollback | snapshot | snapshot-delete | suspended | suspending>` ::
491
492Lock/unlock the VM.
493
494`machine`: `(pc|pc(-i440fx)?-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|q35|pc-q35-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|virt(?:-\d+(\.\d+)+)?(\+pve\d+)?)` ::
495
496Specifies the Qemu machine type.
497
498`memory`: `<integer> (16 - N)` ('default =' `512`)::
499
500Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
501
502`migrate_downtime`: `<number> (0 - N)` ('default =' `0.1`)::
503
504Set maximum tolerated downtime (in seconds) for migrations.
505
506`migrate_speed`: `<integer> (0 - N)` ('default =' `0`)::
507
508Set maximum speed (in MB/s) for migrations. Value 0 is no limit.
509
510`name`: `<string>` ::
511
512Set a name for the VM. Only used on the configuration web interface.
513
514`nameserver`: `<string>` ::
515
516cloud-init: Sets DNS server IP address for a container. Create will'
517 .' automatically use the setting from the host if neither searchdomain nor nameserver'
518 .' are set.
519
520`net[n]`: `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,mtu=<integer>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
521
522Specify network devices.
523
524`bridge`=`<bridge>` ;;
525
526Bridge to attach the network device to. The Proxmox VE standard bridge
527is called 'vmbr0'.
528+
529If you do not specify a bridge, we create a kvm user (NATed) network
530device, which provides DHCP and DNS services. The following addresses
531are used:
532+
533 10.0.2.2 Gateway
534 10.0.2.3 DNS Server
535 10.0.2.4 SMB Server
536+
537The DHCP server assign addresses to the guest starting from 10.0.2.15.
538
539`firewall`=`<boolean>` ;;
540
541Whether this interface should be protected by the firewall.
542
543`link_down`=`<boolean>` ;;
544
545Whether this interface should be disconnected (like pulling the plug).
546
547`macaddr`=`<XX:XX:XX:XX:XX:XX>` ;;
548
549A common MAC address with the I/G (Individual/Group) bit not set.
550
551`model`=`<e1000 | e1000-82540em | e1000-82544gc | e1000-82545em | e1000e | i82551 | i82557b | i82559er | ne2k_isa | ne2k_pci | pcnet | rtl8139 | virtio | vmxnet3>` ;;
552
553Network Card Model. The 'virtio' model provides the best performance with very low CPU overhead. If your guest does not support this driver, it is usually best to use 'e1000'.
554
555`mtu`=`<integer> (1 - 65520)` ;;
556
557Force MTU, for VirtIO only. Set to '1' to use the bridge MTU
558
559`queues`=`<integer> (0 - 16)` ;;
560
561Number of packet queues to be used on the device.
562
563`rate`=`<number> (0 - N)` ;;
564
565Rate limit in mbps (megabytes per second) as floating point number.
566
567`tag`=`<integer> (1 - 4094)` ;;
568
569VLAN tag to apply to packets on this interface.
570
571`trunks`=`<vlanid[;vlanid...]>` ;;
572
573VLAN trunks to pass through this interface.
574
575`numa`: `<boolean>` ('default =' `0`)::
576
577Enable/disable NUMA.
578
579`numa[n]`: `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<number>] [,policy=<preferred|bind|interleave>]` ::
580
581NUMA topology.
582
583`cpus`=`<id[-id];...>` ;;
584
585CPUs accessing this NUMA node.
586
587`hostnodes`=`<id[-id];...>` ;;
588
589Host NUMA nodes to use.
590
591`memory`=`<number>` ;;
592
593Amount of memory this NUMA node provides.
594
595`policy`=`<bind | interleave | preferred>` ;;
596
597NUMA allocation policy.
598
599`onboot`: `<boolean>` ('default =' `0`)::
600
601Specifies whether a VM will be started during system bootup.
602
603`ostype`: `<l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win10 | win11 | win7 | win8 | wvista | wxp>` ::
604
605Specify guest operating system. This is used to enable special
606optimization/features for specific operating systems:
607+
608[horizontal]
609other;; unspecified OS
610wxp;; Microsoft Windows XP
611w2k;; Microsoft Windows 2000
612w2k3;; Microsoft Windows 2003
613w2k8;; Microsoft Windows 2008
614wvista;; Microsoft Windows Vista
615win7;; Microsoft Windows 7
616win8;; Microsoft Windows 8/2012/2012r2
617win10;; Microsoft Windows 10/2016/2019
618win11;; Microsoft Windows 11/2022
619l24;; Linux 2.4 Kernel
620l26;; Linux 2.6 - 5.X Kernel
621solaris;; Solaris/OpenSolaris/OpenIndiania kernel
622
623`parallel[n]`: `/dev/parport\d+|/dev/usb/lp\d+` ::
624
625Map host parallel devices (n is 0 to 2).
626+
627NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
628machines - use with special care.
629+
630CAUTION: Experimental! User reported problems with this option.
631
632`protection`: `<boolean>` ('default =' `0`)::
633
634Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.
635
636`reboot`: `<boolean>` ('default =' `1`)::
637
638Allow reboot. If set to '0' the VM exit on reboot.
639
640`rng0`: `[source=]</dev/urandom|/dev/random|/dev/hwrng> [,max_bytes=<integer>] [,period=<integer>]` ::
641
642Configure a VirtIO-based Random Number Generator.
643
644`max_bytes`=`<integer>` ('default =' `1024`);;
645
646Maximum bytes of entropy allowed to get injected into the guest every 'period' milliseconds. Prefer a lower value when using '/dev/random' as source. Use `0` to disable limiting (potentially dangerous!).
647
648`period`=`<integer>` ('default =' `1000`);;
649
650Every 'period' milliseconds the entropy-injection quota is reset, allowing the guest to retrieve another 'max_bytes' of entropy.
651
652`source`=`</dev/hwrng | /dev/random | /dev/urandom>` ;;
653
654The file on the host to gather entropy from. In most cases '/dev/urandom' should be preferred over '/dev/random' to avoid entropy-starvation issues on the host. Using urandom does *not* decrease security in any meaningful way, as it's still seeded from real entropy, and the bytes provided will most likely be mixed with real entropy on the guest as well. '/dev/hwrng' can be used to pass through a hardware RNG from the host.
655
656`sata[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
657
658Use volume as SATA hard disk or CD-ROM (n is 0 to 5). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
659
660`aio`=`<io_uring | native | threads>` ;;
661
662AIO type to use.
663
664`backup`=`<boolean>` ;;
665
666Whether the drive should be included when making backups.
667
668`bps`=`<bps>` ;;
669
670Maximum r/w speed in bytes per second.
671
672`bps_max_length`=`<seconds>` ;;
673
674Maximum length of I/O bursts in seconds.
675
676`bps_rd`=`<bps>` ;;
677
678Maximum read speed in bytes per second.
679
680`bps_rd_max_length`=`<seconds>` ;;
681
682Maximum length of read I/O bursts in seconds.
683
684`bps_wr`=`<bps>` ;;
685
686Maximum write speed in bytes per second.
687
688`bps_wr_max_length`=`<seconds>` ;;
689
690Maximum length of write I/O bursts in seconds.
691
692`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
693
694The drive's cache mode
695
696`cyls`=`<integer>` ;;
697
698Force the drive's physical geometry to have a specific cylinder count.
699
700`detect_zeroes`=`<boolean>` ;;
701
702Controls whether to detect and try to optimize writes of zeroes.
703
704`discard`=`<ignore | on>` ;;
705
706Controls whether to pass discard/trim requests to the underlying storage.
707
708`file`=`<volume>` ;;
709
710The drive's backing volume.
711
712`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
713
714The drive's backing file's data format.
715
716`heads`=`<integer>` ;;
717
718Force the drive's physical geometry to have a specific head count.
719
720`iops`=`<iops>` ;;
721
722Maximum r/w I/O in operations per second.
723
724`iops_max`=`<iops>` ;;
725
726Maximum unthrottled r/w I/O pool in operations per second.
727
728`iops_max_length`=`<seconds>` ;;
729
730Maximum length of I/O bursts in seconds.
731
732`iops_rd`=`<iops>` ;;
733
734Maximum read I/O in operations per second.
735
736`iops_rd_max`=`<iops>` ;;
737
738Maximum unthrottled read I/O pool in operations per second.
739
740`iops_rd_max_length`=`<seconds>` ;;
741
742Maximum length of read I/O bursts in seconds.
743
744`iops_wr`=`<iops>` ;;
745
746Maximum write I/O in operations per second.
747
748`iops_wr_max`=`<iops>` ;;
749
750Maximum unthrottled write I/O pool in operations per second.
751
752`iops_wr_max_length`=`<seconds>` ;;
753
754Maximum length of write I/O bursts in seconds.
755
756`mbps`=`<mbps>` ;;
757
758Maximum r/w speed in megabytes per second.
759
760`mbps_max`=`<mbps>` ;;
761
762Maximum unthrottled r/w pool in megabytes per second.
763
764`mbps_rd`=`<mbps>` ;;
765
766Maximum read speed in megabytes per second.
767
768`mbps_rd_max`=`<mbps>` ;;
769
770Maximum unthrottled read pool in megabytes per second.
771
772`mbps_wr`=`<mbps>` ;;
773
774Maximum write speed in megabytes per second.
775
776`mbps_wr_max`=`<mbps>` ;;
777
778Maximum unthrottled write pool in megabytes per second.
779
780`media`=`<cdrom | disk>` ('default =' `disk`);;
781
782The drive's media type.
783
784`replicate`=`<boolean>` ('default =' `1`);;
785
786Whether the drive should considered for replication jobs.
787
788`rerror`=`<ignore | report | stop>` ;;
789
790Read error action.
791
792`secs`=`<integer>` ;;
793
794Force the drive's physical geometry to have a specific sector count.
795
796`serial`=`<serial>` ;;
797
798The drive's reported serial number, url-encoded, up to 20 bytes long.
799
800`shared`=`<boolean>` ('default =' `0`);;
801
802Mark this locally-managed volume as available on all nodes.
803+
804WARNING: This option does not share the volume automatically, it assumes it is shared already!
805
806`size`=`<DiskSize>` ;;
807
808Disk size. This is purely informational and has no effect.
809
810`snapshot`=`<boolean>` ;;
811
812Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
813
814`ssd`=`<boolean>` ;;
815
816Whether to expose this drive as an SSD, rather than a rotational hard disk.
817
818`trans`=`<auto | lba | none>` ;;
819
820Force disk geometry bios translation mode.
821
822`werror`=`<enospc | ignore | report | stop>` ;;
823
824Write error action.
825
826`wwn`=`<wwn>` ;;
827
828The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
829
830`scsi[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,ro=<1|0>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
831
832Use volume as SCSI hard disk or CD-ROM (n is 0 to 30). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
833
834`aio`=`<io_uring | native | threads>` ;;
835
836AIO type to use.
837
838`backup`=`<boolean>` ;;
839
840Whether the drive should be included when making backups.
841
842`bps`=`<bps>` ;;
843
844Maximum r/w speed in bytes per second.
845
846`bps_max_length`=`<seconds>` ;;
847
848Maximum length of I/O bursts in seconds.
849
850`bps_rd`=`<bps>` ;;
851
852Maximum read speed in bytes per second.
853
854`bps_rd_max_length`=`<seconds>` ;;
855
856Maximum length of read I/O bursts in seconds.
857
858`bps_wr`=`<bps>` ;;
859
860Maximum write speed in bytes per second.
861
862`bps_wr_max_length`=`<seconds>` ;;
863
864Maximum length of write I/O bursts in seconds.
865
866`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
867
868The drive's cache mode
869
870`cyls`=`<integer>` ;;
871
872Force the drive's physical geometry to have a specific cylinder count.
873
874`detect_zeroes`=`<boolean>` ;;
875
876Controls whether to detect and try to optimize writes of zeroes.
877
878`discard`=`<ignore | on>` ;;
879
880Controls whether to pass discard/trim requests to the underlying storage.
881
882`file`=`<volume>` ;;
883
884The drive's backing volume.
885
886`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
887
888The drive's backing file's data format.
889
890`heads`=`<integer>` ;;
891
892Force the drive's physical geometry to have a specific head count.
893
894`iops`=`<iops>` ;;
895
896Maximum r/w I/O in operations per second.
897
898`iops_max`=`<iops>` ;;
899
900Maximum unthrottled r/w I/O pool in operations per second.
901
902`iops_max_length`=`<seconds>` ;;
903
904Maximum length of I/O bursts in seconds.
905
906`iops_rd`=`<iops>` ;;
907
908Maximum read I/O in operations per second.
909
910`iops_rd_max`=`<iops>` ;;
911
912Maximum unthrottled read I/O pool in operations per second.
913
914`iops_rd_max_length`=`<seconds>` ;;
915
916Maximum length of read I/O bursts in seconds.
917
918`iops_wr`=`<iops>` ;;
919
920Maximum write I/O in operations per second.
921
922`iops_wr_max`=`<iops>` ;;
923
924Maximum unthrottled write I/O pool in operations per second.
925
926`iops_wr_max_length`=`<seconds>` ;;
927
928Maximum length of write I/O bursts in seconds.
929
930`iothread`=`<boolean>` ;;
931
932Whether to use iothreads for this drive
933
934`mbps`=`<mbps>` ;;
935
936Maximum r/w speed in megabytes per second.
937
938`mbps_max`=`<mbps>` ;;
939
940Maximum unthrottled r/w pool in megabytes per second.
941
942`mbps_rd`=`<mbps>` ;;
943
944Maximum read speed in megabytes per second.
945
946`mbps_rd_max`=`<mbps>` ;;
947
948Maximum unthrottled read pool in megabytes per second.
949
950`mbps_wr`=`<mbps>` ;;
951
952Maximum write speed in megabytes per second.
953
954`mbps_wr_max`=`<mbps>` ;;
955
956Maximum unthrottled write pool in megabytes per second.
957
958`media`=`<cdrom | disk>` ('default =' `disk`);;
959
960The drive's media type.
961
962`queues`=`<integer> (2 - N)` ;;
963
964Number of queues.
965
966`replicate`=`<boolean>` ('default =' `1`);;
967
968Whether the drive should considered for replication jobs.
969
970`rerror`=`<ignore | report | stop>` ;;
971
972Read error action.
973
974`ro`=`<boolean>` ;;
975
976Whether the drive is read-only.
977
978`scsiblock`=`<boolean>` ('default =' `0`);;
979
980whether to use scsi-block for full passthrough of host block device
981+
982WARNING: can lead to I/O errors in combination with low memory or high memory fragmentation on host
983
984`secs`=`<integer>` ;;
985
986Force the drive's physical geometry to have a specific sector count.
987
988`serial`=`<serial>` ;;
989
990The drive's reported serial number, url-encoded, up to 20 bytes long.
991
992`shared`=`<boolean>` ('default =' `0`);;
993
994Mark this locally-managed volume as available on all nodes.
995+
996WARNING: This option does not share the volume automatically, it assumes it is shared already!
997
998`size`=`<DiskSize>` ;;
999
1000Disk size. This is purely informational and has no effect.
1001
1002`snapshot`=`<boolean>` ;;
1003
1004Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
1005
1006`ssd`=`<boolean>` ;;
1007
1008Whether to expose this drive as an SSD, rather than a rotational hard disk.
1009
1010`trans`=`<auto | lba | none>` ;;
1011
1012Force disk geometry bios translation mode.
1013
1014`werror`=`<enospc | ignore | report | stop>` ;;
1015
1016Write error action.
1017
1018`wwn`=`<wwn>` ;;
1019
1020The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
1021
1022`scsihw`: `<lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single>` ('default =' `lsi`)::
1023
1024SCSI controller model
1025
1026`searchdomain`: `<string>` ::
1027
1028cloud-init: Sets DNS search domains for a container. Create will'
1029 .' automatically use the setting from the host if neither searchdomain nor nameserver'
1030 .' are set.
1031
1032`serial[n]`: `(/dev/.+|socket)` ::
1033
1034Create a serial device inside the VM (n is 0 to 3), and pass through a
1035host serial device (i.e. /dev/ttyS0), or create a unix socket on the
1036host side (use 'qm terminal' to open a terminal connection).
1037+
1038NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines -
1039use with special care.
1040+
1041CAUTION: Experimental! User reported problems with this option.
1042
1043`shares`: `<integer> (0 - 50000)` ('default =' `1000`)::
1044
1045Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.
1046
1047`smbios1`: `[base64=<1|0>] [,family=<Base64 encoded string>] [,manufacturer=<Base64 encoded string>] [,product=<Base64 encoded string>] [,serial=<Base64 encoded string>] [,sku=<Base64 encoded string>] [,uuid=<UUID>] [,version=<Base64 encoded string>]` ::
1048
1049Specify SMBIOS type 1 fields.
1050
1051`base64`=`<boolean>` ;;
1052
1053Flag to indicate that the SMBIOS values are base64 encoded
1054
1055`family`=`<Base64 encoded string>` ;;
1056
1057Set SMBIOS1 family string.
1058
1059`manufacturer`=`<Base64 encoded string>` ;;
1060
1061Set SMBIOS1 manufacturer.
1062
1063`product`=`<Base64 encoded string>` ;;
1064
1065Set SMBIOS1 product ID.
1066
1067`serial`=`<Base64 encoded string>` ;;
1068
1069Set SMBIOS1 serial number.
1070
1071`sku`=`<Base64 encoded string>` ;;
1072
1073Set SMBIOS1 SKU string.
1074
1075`uuid`=`<UUID>` ;;
1076
1077Set SMBIOS1 UUID.
1078
1079`version`=`<Base64 encoded string>` ;;
1080
1081Set SMBIOS1 version.
1082
1083`smp`: `<integer> (1 - N)` ('default =' `1`)::
1084
1085The number of CPUs. Please use option -sockets instead.
1086
1087`sockets`: `<integer> (1 - N)` ('default =' `1`)::
1088
1089The number of CPU sockets.
1090
1091`spice_enhancements`: `[foldersharing=<1|0>] [,videostreaming=<off|all|filter>]` ::
1092
1093Configure additional enhancements for SPICE.
1094
1095`foldersharing`=`<boolean>` ('default =' `0`);;
1096
1097Enable folder sharing via SPICE. Needs Spice-WebDAV daemon installed in the VM.
1098
1099`videostreaming`=`<all | filter | off>` ('default =' `off`);;
1100
1101Enable video streaming. Uses compression for detected video streams.
1102
1103`sshkeys`: `<string>` ::
1104
1105cloud-init: Setup public SSH keys (one key per line, OpenSSH format).
1106
1107`startdate`: `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` ('default =' `now`)::
1108
1109Set the initial date of the real time clock. Valid format for date are:'now' or '2006-06-17T16:01:21' or '2006-06-17'.
1110
1111`startup`: `[[order=]\d+] [,up=\d+] [,down=\d+] ` ::
1112
1113Startup and shutdown behavior. Order is a non-negative number defining the general startup order. Shutdown in done with reverse ordering. Additionally you can set the 'up' or 'down' delay in seconds, which specifies a delay to wait before the next VM is started or stopped.
1114
1115`tablet`: `<boolean>` ('default =' `1`)::
1116
1117Enable/disable the USB tablet device. This device is usually needed to allow absolute mouse positioning with VNC. Else the mouse runs out of sync with normal VNC clients. If you're running lots of console-only guests on one host, you may consider disabling this to save some context switches. This is turned off by default if you use spice (`qm set <vmid> --vga qxl`).
1118
1119`tags`: `<string>` ::
1120
1121Tags of the VM. This is only meta information.
1122
1123`tdf`: `<boolean>` ('default =' `0`)::
1124
1125Enable/disable time drift fix.
1126
1127`template`: `<boolean>` ('default =' `0`)::
1128
1129Enable/disable Template.
1130
1131`tpmstate0`: `[file=]<volume> [,size=<DiskSize>] [,version=<v1.2|v2.0>]` ::
1132
1133Configure a Disk for storing TPM state. Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume. Note that SIZE_IN_GiB is ignored here and that the default size of 4 MiB will always be used instead. The format is also fixed to 'raw'.
1134
1135`file`=`<volume>` ;;
1136
1137The drive's backing volume.
1138
1139`size`=`<DiskSize>` ;;
1140
1141Disk size. This is purely informational and has no effect.
1142
1143`version`=`<v1.2 | v2.0>` ('default =' `v2.0`);;
1144
1145The TPM interface version. v2.0 is newer and should be preferred. Note that this cannot be changed later on.
1146
1147`unused[n]`: `[file=]<volume>` ::
1148
1149Reference to unused volumes. This is used internally, and should not be modified manually.
1150
1151`file`=`<volume>` ;;
1152
1153The drive's backing volume.
1154
1155`usb[n]`: `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
1156
1157Configure an USB device (n is 0 to 4).
1158
1159`host`=`<HOSTUSBDEVICE|spice>` ;;
1160
1161The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
1162+
1163 'bus-port(.port)*' (decimal numbers) or
1164 'vendor_id:product_id' (hexadeciaml numbers) or
1165 'spice'
1166+
1167You can use the 'lsusb -t' command to list existing usb devices.
1168+
1169NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
1170machines - use with special care.
1171+
1172The value 'spice' can be used to add a usb redirection devices for spice.
1173
1174`usb3`=`<boolean>` ('default =' `0`);;
1175
1176Specifies whether if given host option is a USB3 device or port.
1177
1178`vcpus`: `<integer> (1 - N)` ('default =' `0`)::
1179
1180Number of hotplugged vcpus.
1181
1182`vga`: `[[type=]<enum>] [,memory=<integer>]` ::
1183
1184Configure the VGA Hardware. If you want to use high resolution modes (>= 1280x1024x16) you may need to increase the vga memory option. Since QEMU 2.9 the default VGA display type is 'std' for all OS types besides some Windows versions (XP and older) which use 'cirrus'. The 'qxl' option enables the SPICE display server. For win* OS you can select how many independent displays you want, Linux guests can add displays them self.
1185You can also run without any graphic card, using a serial device as terminal.
1186
1187`memory`=`<integer> (4 - 512)` ;;
1188
1189Sets the VGA memory (in MiB). Has no effect with serial display.
1190
1191`type`=`<cirrus | none | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | virtio | vmware>` ('default =' `std`);;
1192
1193Select the VGA type.
1194
1195`virtio[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,ro=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
1196
1197Use volume as VIRTIO hard disk (n is 0 to 15). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
1198
1199`aio`=`<io_uring | native | threads>` ;;
1200
1201AIO type to use.
1202
1203`backup`=`<boolean>` ;;
1204
1205Whether the drive should be included when making backups.
1206
1207`bps`=`<bps>` ;;
1208
1209Maximum r/w speed in bytes per second.
1210
1211`bps_max_length`=`<seconds>` ;;
1212
1213Maximum length of I/O bursts in seconds.
1214
1215`bps_rd`=`<bps>` ;;
1216
1217Maximum read speed in bytes per second.
1218
1219`bps_rd_max_length`=`<seconds>` ;;
1220
1221Maximum length of read I/O bursts in seconds.
1222
1223`bps_wr`=`<bps>` ;;
1224
1225Maximum write speed in bytes per second.
1226
1227`bps_wr_max_length`=`<seconds>` ;;
1228
1229Maximum length of write I/O bursts in seconds.
1230
1231`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
1232
1233The drive's cache mode
1234
1235`cyls`=`<integer>` ;;
1236
1237Force the drive's physical geometry to have a specific cylinder count.
1238
1239`detect_zeroes`=`<boolean>` ;;
1240
1241Controls whether to detect and try to optimize writes of zeroes.
1242
1243`discard`=`<ignore | on>` ;;
1244
1245Controls whether to pass discard/trim requests to the underlying storage.
1246
1247`file`=`<volume>` ;;
1248
1249The drive's backing volume.
1250
1251`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
1252
1253The drive's backing file's data format.
1254
1255`heads`=`<integer>` ;;
1256
1257Force the drive's physical geometry to have a specific head count.
1258
1259`iops`=`<iops>` ;;
1260
1261Maximum r/w I/O in operations per second.
1262
1263`iops_max`=`<iops>` ;;
1264
1265Maximum unthrottled r/w I/O pool in operations per second.
1266
1267`iops_max_length`=`<seconds>` ;;
1268
1269Maximum length of I/O bursts in seconds.
1270
1271`iops_rd`=`<iops>` ;;
1272
1273Maximum read I/O in operations per second.
1274
1275`iops_rd_max`=`<iops>` ;;
1276
1277Maximum unthrottled read I/O pool in operations per second.
1278
1279`iops_rd_max_length`=`<seconds>` ;;
1280
1281Maximum length of read I/O bursts in seconds.
1282
1283`iops_wr`=`<iops>` ;;
1284
1285Maximum write I/O in operations per second.
1286
1287`iops_wr_max`=`<iops>` ;;
1288
1289Maximum unthrottled write I/O pool in operations per second.
1290
1291`iops_wr_max_length`=`<seconds>` ;;
1292
1293Maximum length of write I/O bursts in seconds.
1294
1295`iothread`=`<boolean>` ;;
1296
1297Whether to use iothreads for this drive
1298
1299`mbps`=`<mbps>` ;;
1300
1301Maximum r/w speed in megabytes per second.
1302
1303`mbps_max`=`<mbps>` ;;
1304
1305Maximum unthrottled r/w pool in megabytes per second.
1306
1307`mbps_rd`=`<mbps>` ;;
1308
1309Maximum read speed in megabytes per second.
1310
1311`mbps_rd_max`=`<mbps>` ;;
1312
1313Maximum unthrottled read pool in megabytes per second.
1314
1315`mbps_wr`=`<mbps>` ;;
1316
1317Maximum write speed in megabytes per second.
1318
1319`mbps_wr_max`=`<mbps>` ;;
1320
1321Maximum unthrottled write pool in megabytes per second.
1322
1323`media`=`<cdrom | disk>` ('default =' `disk`);;
1324
1325The drive's media type.
1326
1327`replicate`=`<boolean>` ('default =' `1`);;
1328
1329Whether the drive should considered for replication jobs.
1330
1331`rerror`=`<ignore | report | stop>` ;;
1332
1333Read error action.
1334
1335`ro`=`<boolean>` ;;
1336
1337Whether the drive is read-only.
1338
1339`secs`=`<integer>` ;;
1340
1341Force the drive's physical geometry to have a specific sector count.
1342
1343`serial`=`<serial>` ;;
1344
1345The drive's reported serial number, url-encoded, up to 20 bytes long.
1346
1347`shared`=`<boolean>` ('default =' `0`);;
1348
1349Mark this locally-managed volume as available on all nodes.
1350+
1351WARNING: This option does not share the volume automatically, it assumes it is shared already!
1352
1353`size`=`<DiskSize>` ;;
1354
1355Disk size. This is purely informational and has no effect.
1356
1357`snapshot`=`<boolean>` ;;
1358
1359Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
1360
1361`trans`=`<auto | lba | none>` ;;
1362
1363Force disk geometry bios translation mode.
1364
1365`werror`=`<enospc | ignore | report | stop>` ;;
1366
1367Write error action.
1368
1369`vmgenid`: `<UUID>` ('default =' `1 (autogenerated)`)::
1370
1371The VM generation ID (vmgenid) device exposes a 128-bit integer value identifier to the guest OS. This allows to notify the guest operating system when the virtual machine is executed with a different configuration (e.g. snapshot execution or creation from a template). The guest operating system notices the change, and is then able to react as appropriate by marking its copies of distributed databases as dirty, re-initializing its random number generator, etc.
1372Note that auto-creation only works when done through API/CLI create or update methods, but not when manually editing the config file.
1373
1374`vmstatestorage`: `<string>` ::
1375
1376Default storage for VM state volumes/files.
1377
1378`watchdog`: `[[model=]<i6300esb|ib700>] [,action=<enum>]` ::
1379
1380Create a virtual hardware watchdog device. Once enabled (by a guest action), the watchdog must be periodically polled by an agent inside the guest or else the watchdog will reset the guest (or execute the respective action specified)
1381
1382`action`=`<debug | none | pause | poweroff | reset | shutdown>` ;;
1383
1384The action to perform if after activation the guest fails to poll the watchdog in time.
1385
1386`model`=`<i6300esb | ib700>` ('default =' `i6300esb`);;
1387
1388Watchdog type to emulate.
1389