]> git.proxmox.com Git - pve-manager.git/commitdiff
pve6to7: more fine-grained detection of misconfigured guest volumes
authorFabian Ebner <f.ebner@proxmox.com>
Wed, 30 Jun 2021 09:16:18 +0000 (11:16 +0200)
committerFabian Grünbichler <f.gruenbichler@proxmox.com>
Wed, 30 Jun 2021 12:08:20 +0000 (14:08 +0200)
If neither 'rootdir' nor 'images' are configured on a storage, but
there are guest images, just log the number of volumes found. If they
are relevant for migration, the check for unreferenced volumes will
catch them later.

Also detect content type mismatch for all volumes of existing guests,
which also covers the case of a VM image on a storage with only
'rootdir' and vice versa. To catch all such unreferenced volumes too,
it is necessary to scan all storages that do not have both content
types configured.

Change the message from 'will not work' to 'might not work'. If a
volume only referenced by a snapshot is misconfigured, it doesn't mean
that the guest doesn't work at all. Or it might be an ISO on a
misconfigured storage.

Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
PVE/CLI/pve6to7.pm

index 3d5b780b9a15882c35202041db7200179aa45b8c..6dd7760cc7722b1901383f2dcf56b4be56be68e7 100644 (file)
@@ -706,11 +706,15 @@ sub check_description_lengths {
 sub check_storage_content {
     log_info("Checking storage content type configuration..");
 
-    my $found;
+    my $found_referenced;
+    my $found_unreferenced;
     my $pass = 1;
 
     my $storage_cfg = PVE::Storage::config();
 
+    my $potentially_affected = {};
+    my $referenced_volids = {};
+
     for my $storeid (keys $storage_cfg->{ids}->%*) {
        my $scfg = $storage_cfg->{ids}->{$storeid};
 
@@ -724,8 +728,7 @@ sub check_storage_content {
            delete $scfg->{content}->{none}; # scan for guest images below
        }
 
-       next if $scfg->{content}->{images};
-       next if $scfg->{content}->{rootdir};
+       next if $scfg->{content}->{images} && $scfg->{content}->{rootdir};
 
        # Skip 'iscsi(direct)' (and foreign plugins with potentially similiar behavior) with 'none',
        # because that means "use LUNs directly" and vdisk_list() in PVE 6.x still lists those.
@@ -733,22 +736,147 @@ sub check_storage_content {
        # and 'images' or 'rootdir', hence being potentially misconfigured.
        next if $scfg->{type} ne 'dir' && $scfg->{content}->{none};
 
-       my $res = PVE::Storage::vdisk_list($storage_cfg, $storeid);
-       my $disk_list = $res->{$storeid};
+       eval { PVE::Storage::activate_storage($storage_cfg, $storeid) };
+       if (my $err = $@) {
+           log_warn("activating '$storeid' failed - $err");
+           next;
+       }
+
+       my $res = eval { PVE::Storage::vdisk_list($storage_cfg, $storeid); };
+       if (my $err = $@) {
+           log_warn("listing images on '$storeid' failed - $err");
+           next;
+       }
+       my @volids = map { $_->{volid} } $res->{$storeid}->@*;
+
+       for my $volid (@volids) {
+           $potentially_affected->{$volid} = 1;
+       }
+
+       my $number = scalar(@volids);
+       if ($number > 0 && !$scfg->{content}->{images} && !$scfg->{content}->{rootdir}) {
+           log_info("storage '$storeid' - neither content type 'images' nor 'rootdir' configured"
+               .", but found $number guest volume(s)");
+       }
+    }
+
+    my $check_volid = sub {
+       my ($volid, $vmid, $vmtype, $reference) = @_;
+
+       $referenced_volids->{$volid} = 1 if $reference ne 'unreferenced';
+
+       my $guesttext = $vmtype eq 'qemu' ? 'VM' : 'CT';
+       my $prefix = "$guesttext $vmid - volume '$volid' ($reference)";
 
-       my @volumes = map { $_->{volid} } $disk_list->@*;
+       my ($storeid) = PVE::Storage::parse_volume_id($volid, 1);
+       return if !defined($storeid);
 
-       if (scalar(@volumes) > 0) {
-           $found = 1;
+       my $scfg = $storage_cfg->{ids}->{$storeid};
+       if (!$scfg) {
            $pass = 0;
-           log_warn("storage '$storeid' - neither content type 'images' nor 'rootdir' configured"
-               .", but found guest volume(s):\n    " . join("\n    ", @volumes));
+           log_warn("$prefix - storage does not exist!");
+           return;
+       }
+
+       # cannot use parse_volname for containers, as it can return 'images'
+       # but containers cannot have ISO images attached, so assume 'rootdir'
+       my $vtype = 'rootdir';
+       if ($vmtype eq 'qemu') {
+           ($vtype) = eval { PVE::Storage::parse_volname($storage_cfg, $volid); };
+           return if $@;
        }
+
+       if (!$scfg->{content}->{$vtype}) {
+           $found_referenced = 1 if $reference ne 'unreferenced';
+           $found_unreferenced = 1 if $reference eq 'unreferenced';
+           $pass = 0;
+           log_warn("$prefix - storage does not have content type '$vtype' configured.");
+       }
+    };
+
+    my $guests = {};
+
+    my $cts = PVE::LXC::config_list();
+    for my $vmid (sort { $a <=> $b } keys %$cts) {
+       $guests->{$vmid} = 'lxc';
+
+       my $conf = PVE::LXC::Config->load_config($vmid);
+
+       my $volhash = {};
+
+       my $check = sub {
+           my ($ms, $mountpoint, $reference) = @_;
+
+           my $volid = $mountpoint->{volume};
+           return if !$volid || $mountpoint->{type} ne 'volume';
+
+           return if $volhash->{$volid}; # volume might be referenced multiple times
+
+           $volhash->{$volid} = 1;
+
+           $check_volid->($volid, $vmid, 'lxc', $reference);
+       };
+
+       my $opts = { include_unused => 1 };
+       PVE::LXC::Config->foreach_volume_full($conf, $opts, $check, 'in config');
+       for my $snapname (keys $conf->{snapshots}->%*) {
+           my $snap = $conf->{snapshots}->{$snapname};
+           PVE::LXC::Config->foreach_volume_full($snap, $opts, $check, "in snapshot '$snapname'");
+       }
+    }
+
+    my $vms = PVE::QemuServer::config_list();
+    for my $vmid (sort { $a <=> $b } keys %$vms) {
+       $guests->{$vmid} = 'qemu';
+
+       my $conf = PVE::QemuConfig->load_config($vmid);
+
+       my $volhash = {};
+
+       my $check = sub {
+           my ($key, $drive, $reference) = @_;
+
+           my $volid = $drive->{file};
+           return if $volid =~ m|^/|;
+
+           return if $volhash->{$volid}; # volume might be referenced multiple times
+
+           $volhash->{$volid} = 1;
+
+           $check_volid->($volid, $vmid, 'qemu', $reference);
+       };
+
+       my $opts = {
+           extra_keys => ['vmstate'],
+           include_unused => 1,
+       };
+       # startup from a suspended state works even without 'images' content type on the
+       # state storage, so do not check 'vmstate' for $conf
+       PVE::QemuConfig->foreach_volume_full($conf, { include_unused => 1 }, $check, 'in config');
+       for my $snapname (keys $conf->{snapshots}->%*) {
+           my $snap = $conf->{snapshots}->{$snapname};
+           PVE::QemuConfig->foreach_volume_full($snap, $opts, $check, "in snapshot '$snapname'");
+       }
+    }
+
+    if ($found_referenced) {
+       log_warn("Proxmox VE 7.0 enforces stricter content type checks. The guests above " .
+           "might not work until the storage configuration is fixed.");
+    }
+
+    for my $volid (sort keys $potentially_affected->%*) {
+       next if $referenced_volids->{$volid}; # already checked
+
+       my (undef, undef, $vmid) = PVE::Storage::parse_volname($storage_cfg, $volid);
+       my $vmtype = $guests->{$vmid};
+       next if !$vmtype;
+
+       $check_volid->($volid, $vmid, $vmtype, 'unreferenced');
     }
 
-    if ($found) {
-       log_warn("PVE 7.0 enforces stricter content type checks. Guests referencing the above " .
-           "volumes will not work until the storage configuration is fixed.");
+    if ($found_unreferenced) {
+       log_warn("When migrating, Proxmox VE 7.0 only scans storages with the appropriate " .
+           "content types for unreferenced guest volumes.");
     }
 
     if ($pass) {