1 package PVE
::QemuServer
;
11 use File
::Copy
qw(copy);
24 use Storable
qw(dclone);
25 use Time
::HiRes
qw(gettimeofday);
29 use PVE
::Cluster
qw(cfs_register_file cfs_read_file cfs_write_file cfs_lock_file);
30 use PVE
::DataCenterConfig
;
31 use PVE
::Exception
qw(raise raise_param_exc);
32 use PVE
::GuestHelpers
qw(safe_string_ne safe_num_ne safe_boolean_ne);
34 use PVE
::JSONSchema
qw(get_standard_option);
36 use PVE
::RPCEnvironment
;
40 use PVE
::Tools
qw(run_command lock_file lock_file_full file_read_firstline file_get_contents dir_glob_foreach get_host_arch $IPV6RE);
44 use PVE
::QemuServer
::Helpers
qw(min_version config_aware_timeout);
45 use PVE
::QemuServer
::Cloudinit
;
46 use PVE
::QemuServer
::CPUConfig
qw(print_cpu_device get_cpu_options);
47 use PVE
::QemuServer
::Drive
qw(is_valid_drivename drive_is_cloudinit drive_is_cdrom parse_drive print_drive foreach_drive foreach_volid);
48 use PVE
::QemuServer
::Machine
;
49 use PVE
::QemuServer
::Memory
;
50 use PVE
::QemuServer
::Monitor
qw(mon_cmd);
51 use PVE
::QemuServer
::PCI
qw(print_pci_addr print_pcie_addr print_pcie_root_port);
52 use PVE
::QemuServer
::USB
qw(parse_usb_device);
56 require PVE
::Network
::SDN
::Zones
;
60 my $EDK2_FW_BASE = '/usr/share/pve-edk2-firmware/';
63 "$EDK2_FW_BASE/OVMF_CODE.fd",
64 "$EDK2_FW_BASE/OVMF_VARS.fd"
67 "$EDK2_FW_BASE/AAVMF_CODE.fd",
68 "$EDK2_FW_BASE/AAVMF_VARS.fd"
72 my $cpuinfo = PVE
::ProcFSTools
::read_cpuinfo
();
74 # Note about locking: we use flock on the config file protect
75 # against concurent actions.
76 # Aditionaly, we have a 'lock' setting in the config file. This
77 # can be set to 'migrate', 'backup', 'snapshot' or 'rollback'. Most actions are not
78 # allowed when such lock is set. But you can ignore this kind of
79 # lock with the --skiplock flag.
81 cfs_register_file
('/qemu-server/',
85 PVE
::JSONSchema
::register_standard_option
('pve-qm-stateuri', {
86 description
=> "Some command save/restore state from this location.",
92 PVE
::JSONSchema
::register_standard_option
('pve-qemu-machine', {
93 description
=> "Specifies the Qemu machine type.",
95 pattern
=> '(pc|pc(-i440fx)?-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|q35|pc-q35-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|virt(?:-\d+(\.\d+)+)?(\+pve\d+)?)',
102 my ($map, $source) = @_;
104 return $source if !defined($map);
106 return $map->{entries
}->{$source}
107 if $map->{entries
} && defined($map->{entries
}->{$source});
109 return $map->{default} if $map->{default};
111 # identity (fallback)
115 PVE
::JSONSchema
::register_standard_option
('pve-targetstorage', {
116 description
=> "Mapping from source to target storages. Providing only a single storage ID maps all source storages to that storage. Providing the special value '1' will map each source storage to itself.",
118 format
=> 'storagepair-list',
122 #no warnings 'redefine';
125 my ($controller, $vmid, $option, $value) = @_;
127 my $path = "/sys/fs/cgroup/$controller/qemu.slice/$vmid.scope/$option";
128 PVE
::ProcFSTools
::write_proc_entry
($path, $value);
134 $nodename_cache //= PVE
::INotify
::nodename
();
135 return $nodename_cache;
142 enum
=> [qw(i6300esb ib700)],
143 description
=> "Watchdog type to emulate.",
144 default => 'i6300esb',
149 enum
=> [qw(reset shutdown poweroff pause debug none)],
150 description
=> "The action to perform if after activation the guest fails to poll the watchdog in time.",
154 PVE
::JSONSchema
::register_format
('pve-qm-watchdog', $watchdog_fmt);
158 description
=> "Enable/disable Qemu GuestAgent.",
163 fstrim_cloned_disks
=> {
164 description
=> "Run fstrim after cloning/moving a disk.",
170 description
=> "Select the agent type",
174 enum
=> [qw(virtio isa)],
180 description
=> "Select the VGA type.",
185 enum
=> [qw(cirrus qxl qxl2 qxl3 qxl4 none serial0 serial1 serial2 serial3 std virtio vmware)],
188 description
=> "Sets the VGA memory (in MiB). Has no effect with serial display.",
200 description
=> "The size of the file in MB.",
204 pattern
=> '[a-zA-Z0-9\-]+',
206 format_description
=> 'string',
207 description
=> "The name of the file. Will be prefixed with 'pve-shm-'. Default is the VMID. Will be deleted when the VM is stopped.",
214 enum
=> [qw(ich9-intel-hda intel-hda AC97)],
215 description
=> "Configure an audio device."
222 description
=> "Driver backend for the audio device."
226 my $spice_enhancements_fmt = {
231 description
=> "Enable folder sharing via SPICE. Needs Spice-WebDAV daemon installed in the VM."
235 enum
=> ['off', 'all', 'filter'],
238 description
=> "Enable video streaming. Uses compression for detected video streams."
245 enum
=> ['/dev/urandom', '/dev/random', '/dev/hwrng'],
247 description
=> "The file on the host to gather entropy from. In most"
248 . " cases /dev/urandom should be preferred over /dev/random"
249 . " to avoid entropy-starvation issues on the host. Using"
250 . " urandom does *not* decrease security in any meaningful"
251 . " way, as it's still seeded from real entropy, and the"
252 . " bytes provided will most likely be mixed with real"
253 . " entropy on the guest as well. /dev/hwrng can be used"
254 . " to pass through a hardware RNG from the host.",
258 description
=> "Maximum bytes of entropy injected into the guest every"
259 . " 'period' milliseconds. Prefer a lower value when using"
260 . " /dev/random as source. Use 0 to disable limiting"
261 . " (potentially dangerous!).",
264 # default is 1 KiB/s, provides enough entropy to the guest to avoid
265 # boot-starvation issues (e.g. systemd etc...) while allowing no chance
266 # of overwhelming the host, provided we're reading from /dev/urandom
271 description
=> "Every 'period' milliseconds the entropy-injection quota"
272 . " is reset, allowing the guest to retrieve another"
273 . " 'max_bytes' of entropy.",
283 description
=> "Specifies whether a VM will be started during system bootup.",
289 description
=> "Automatic restart after crash (currently ignored).",
294 type
=> 'string', format
=> 'pve-hotplug-features',
295 description
=> "Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.",
296 default => 'network,disk,usb',
301 description
=> "Allow reboot. If set to '0' the VM exit on reboot.",
307 description
=> "Lock/unlock the VM.",
308 enum
=> [qw(backup clone create migrate rollback snapshot snapshot-delete suspending suspended)],
313 description
=> "Limit of CPU usage.",
314 verbose_description
=> "Limit of CPU usage.\n\nNOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.",
322 description
=> "CPU weight for a VM.",
323 verbose_description
=> "CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.",
331 description
=> "Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.",
338 description
=> "Amount of target RAM for the VM in MB. Using zero disables the ballon driver.",
344 description
=> "Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.",
352 description
=> "Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.cfg' configuration file.".
353 "It should not be necessary to set it.",
354 enum
=> PVE
::Tools
::kvmkeymaplist
(),
359 type
=> 'string', format
=> 'dns-name',
360 description
=> "Set a name for the VM. Only used on the configuration web interface.",
365 description
=> "SCSI controller model",
366 enum
=> [qw(lsi lsi53c810 virtio-scsi-pci virtio-scsi-single megasas pvscsi)],
372 description
=> "Description for the VM. Only used on the configuration web interface. This is saved as comment inside the configuration file.",
377 enum
=> [qw(other wxp w2k w2k3 w2k8 wvista win7 win8 win10 l24 l26 solaris)],
378 description
=> "Specify guest operating system.",
379 verbose_description
=> <<EODESC,
380 Specify guest operating system. This is used to enable special
381 optimization/features for specific operating systems:
384 other;; unspecified OS
385 wxp;; Microsoft Windows XP
386 w2k;; Microsoft Windows 2000
387 w2k3;; Microsoft Windows 2003
388 w2k8;; Microsoft Windows 2008
389 wvista;; Microsoft Windows Vista
390 win7;; Microsoft Windows 7
391 win8;; Microsoft Windows 8/2012/2012r2
392 win10;; Microsoft Windows 10/2016
393 l24;; Linux 2.4 Kernel
394 l26;; Linux 2.6 - 5.X Kernel
395 solaris;; Solaris/OpenSolaris/OpenIndiania kernel
401 description
=> "Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n).",
402 pattern
=> '[acdn]{1,4}',
407 type
=> 'string', format
=> 'pve-qm-bootdisk',
408 description
=> "Enable booting from specified disk.",
409 pattern
=> '(ide|sata|scsi|virtio)\d+',
414 description
=> "The number of CPUs. Please use option -sockets instead.",
421 description
=> "The number of CPU sockets.",
428 description
=> "The number of cores per socket.",
435 description
=> "Enable/disable NUMA.",
441 description
=> "Enable/disable hugepages memory.",
442 enum
=> [qw(any 2 1024)],
447 description
=> "Number of hotplugged vcpus.",
454 description
=> "Enable/disable ACPI.",
459 description
=> "Enable/disable Qemu GuestAgent and its properties.",
461 format
=> $agent_fmt,
466 description
=> "Enable/disable KVM hardware virtualization.",
472 description
=> "Enable/disable time drift fix.",
478 description
=> "Set the real time clock to local time. This is enabled by default if ostype indicates a Microsoft OS.",
483 description
=> "Freeze CPU at startup (use 'c' monitor command to start execution).",
487 type
=> 'string', format
=> $vga_fmt,
488 description
=> "Configure the VGA hardware.",
489 verbose_description
=> "Configure the VGA Hardware. If you want to use ".
490 "high resolution modes (>= 1280x1024x16) you may need to increase " .
491 "the vga memory option. Since QEMU 2.9 the default VGA display type " .
492 "is 'std' for all OS types besides some Windows versions (XP and " .
493 "older) which use 'cirrus'. The 'qxl' option enables the SPICE " .
494 "display server. For win* OS you can select how many independent " .
495 "displays you want, Linux guests can add displays them self.\n".
496 "You can also run without any graphic card, using a serial device as terminal.",
500 type
=> 'string', format
=> 'pve-qm-watchdog',
501 description
=> "Create a virtual hardware watchdog device.",
502 verbose_description
=> "Create a virtual hardware watchdog device. Once enabled" .
503 " (by a guest action), the watchdog must be periodically polled " .
504 "by an agent inside the guest or else the watchdog will reset " .
505 "the guest (or execute the respective action specified)",
510 typetext
=> "(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)",
511 description
=> "Set the initial date of the real time clock. Valid format for date are: 'now' or '2006-06-17T16:01:21' or '2006-06-17'.",
512 pattern
=> '(now|\d{4}-\d{1,2}-\d{1,2}(T\d{1,2}:\d{1,2}:\d{1,2})?)',
515 startup
=> get_standard_option
('pve-startup-order'),
519 description
=> "Enable/disable Template.",
525 description
=> "Arbitrary arguments passed to kvm.",
526 verbose_description
=> <<EODESCR,
527 Arbitrary arguments passed to kvm, for example:
529 args: -no-reboot -no-hpet
531 NOTE: this option is for experts only.
538 description
=> "Enable/disable the USB tablet device.",
539 verbose_description
=> "Enable/disable the USB tablet device. This device is " .
540 "usually needed to allow absolute mouse positioning with VNC. " .
541 "Else the mouse runs out of sync with normal VNC clients. " .
542 "If you're running lots of console-only guests on one host, " .
543 "you may consider disabling this to save some context switches. " .
544 "This is turned off by default if you use spice (-vga=qxl).",
549 description
=> "Set maximum speed (in MB/s) for migrations. Value 0 is no limit.",
553 migrate_downtime
=> {
556 description
=> "Set maximum tolerated downtime (in seconds) for migrations.",
562 type
=> 'string', format
=> 'pve-qm-ide',
563 typetext
=> '<volume>',
564 description
=> "This is an alias for option -ide2",
568 description
=> "Emulated CPU type.",
570 format
=> 'pve-vm-cpu-conf',
572 parent
=> get_standard_option
('pve-snapshot-name', {
574 description
=> "Parent snapshot name. This is used internally, and should not be modified.",
578 description
=> "Timestamp for snapshots.",
584 type
=> 'string', format
=> 'pve-volume-id',
585 description
=> "Reference to a volume which stores the VM state. This is used internally for snapshots.",
587 vmstatestorage
=> get_standard_option
('pve-storage-id', {
588 description
=> "Default storage for VM state volumes/files.",
591 runningmachine
=> get_standard_option
('pve-qemu-machine', {
592 description
=> "Specifies the QEMU machine type of the running vm. This is used internally for snapshots.",
595 description
=> "Specifies the QEMU '-cpu' parameter of the running vm. This is used internally for snapshots.",
598 pattern
=> $PVE::QemuServer
::CPUConfig
::qemu_cmdline_cpu_re
,
599 format_description
=> 'QEMU -cpu parameter'
601 machine
=> get_standard_option
('pve-qemu-machine'),
603 description
=> "Virtual processor architecture. Defaults to the host.",
606 enum
=> [qw(x86_64 aarch64)],
609 description
=> "Specify SMBIOS type 1 fields.",
610 type
=> 'string', format
=> 'pve-qm-smbios1',
617 description
=> "Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.",
623 enum
=> [ qw(seabios ovmf) ],
624 description
=> "Select BIOS implementation.",
625 default => 'seabios',
629 pattern
=> '(?:[a-fA-F0-9]{8}(?:-[a-fA-F0-9]{4}){3}-[a-fA-F0-9]{12}|[01])',
630 format_description
=> 'UUID',
631 description
=> "Set VM Generation ID. Use '1' to autogenerate on create or update, pass '0' to disable explicitly.",
632 verbose_description
=> "The VM generation ID (vmgenid) device exposes a".
633 " 128-bit integer value identifier to the guest OS. This allows to".
634 " notify the guest operating system when the virtual machine is".
635 " executed with a different configuration (e.g. snapshot execution".
636 " or creation from a template). The guest operating system notices".
637 " the change, and is then able to react as appropriate by marking".
638 " its copies of distributed databases as dirty, re-initializing its".
639 " random number generator, etc.\n".
640 "Note that auto-creation only works when done throug API/CLI create".
641 " or update methods, but not when manually editing the config file.",
642 default => "1 (autogenerated)",
647 format
=> 'pve-volume-id',
649 description
=> "Script that will be executed during various steps in the vms lifetime.",
653 format
=> $ivshmem_fmt,
654 description
=> "Inter-VM shared memory. Useful for direct communication between VMs, or to the host.",
659 format
=> $audio_fmt,
660 description
=> "Configure a audio device, useful in combination with QXL/Spice.",
663 spice_enhancements
=> {
665 format
=> $spice_enhancements_fmt,
666 description
=> "Configure additional enhancements for SPICE.",
670 type
=> 'string', format
=> 'pve-tag-list',
671 description
=> 'Tags of the VM. This is only meta information.',
677 description
=> "Configure a VirtIO-based Random Number Generator.",
686 description
=> 'Specify a custom file containing all meta data passed to the VM via cloud-init. This is provider specific meaning configdrive2 and nocloud differ.',
687 format
=> 'pve-volume-id',
688 format_description
=> 'volume',
693 description
=> 'Specify a custom file containing all network data passed to the VM via cloud-init.',
694 format
=> 'pve-volume-id',
695 format_description
=> 'volume',
700 description
=> 'Specify a custom file containing all user data passed to the VM via cloud-init.',
701 format
=> 'pve-volume-id',
702 format_description
=> 'volume',
705 PVE
::JSONSchema
::register_format
('pve-qm-cicustom', $cicustom_fmt);
707 my $confdesc_cloudinit = {
711 description
=> 'Specifies the cloud-init configuration format. The default depends on the configured operating system type (`ostype`. We use the `nocloud` format for Linux, and `configdrive2` for windows.',
712 enum
=> ['configdrive2', 'nocloud'],
717 description
=> "cloud-init: User name to change ssh keys and password for instead of the image's configured default user.",
722 description
=> 'cloud-init: Password to assign the user. Using this is generally not recommended. Use ssh keys instead. Also note that older cloud-init versions do not support hashed passwords.',
727 description
=> 'cloud-init: Specify custom files to replace the automatically generated ones at start.',
728 format
=> 'pve-qm-cicustom',
733 description
=> "cloud-init: Sets DNS search domains for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.",
737 type
=> 'string', format
=> 'address-list',
738 description
=> "cloud-init: Sets DNS server IP address for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.",
743 format
=> 'urlencoded',
744 description
=> "cloud-init: Setup public SSH keys (one key per line, OpenSSH format).",
748 # what about other qemu settings ?
750 #machine => 'string',
763 ##soundhw => 'string',
765 while (my ($k, $v) = each %$confdesc) {
766 PVE
::JSONSchema
::register_standard_option
("pve-qm-$k", $v);
769 my $MAX_USB_DEVICES = 5;
771 my $MAX_HOSTPCI_DEVICES = 16;
772 my $MAX_SERIAL_PORTS = 4;
773 my $MAX_PARALLEL_PORTS = 3;
779 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
780 description
=> "CPUs accessing this NUMA node.",
781 format_description
=> "id[-id];...",
785 description
=> "Amount of memory this NUMA node provides.",
790 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
791 description
=> "Host NUMA nodes to use.",
792 format_description
=> "id[-id];...",
797 enum
=> [qw(preferred bind interleave)],
798 description
=> "NUMA allocation policy.",
802 PVE
::JSONSchema
::register_format
('pve-qm-numanode', $numa_fmt);
805 type
=> 'string', format
=> $numa_fmt,
806 description
=> "NUMA topology.",
808 PVE
::JSONSchema
::register_standard_option
("pve-qm-numanode", $numadesc);
810 for (my $i = 0; $i < $MAX_NUMA; $i++) {
811 $confdesc->{"numa$i"} = $numadesc;
814 my $nic_model_list = ['rtl8139', 'ne2k_pci', 'e1000', 'pcnet', 'virtio',
815 'ne2k_isa', 'i82551', 'i82557b', 'i82559er', 'vmxnet3',
816 'e1000-82540em', 'e1000-82544gc', 'e1000-82545em'];
817 my $nic_model_list_txt = join(' ', sort @$nic_model_list);
819 my $net_fmt_bridge_descr = <<__EOD__;
820 Bridge to attach the network device to. The Proxmox VE standard bridge
823 If you do not specify a bridge, we create a kvm user (NATed) network
824 device, which provides DHCP and DNS services. The following addresses
831 The DHCP server assign addresses to the guest starting from 10.0.2.15.
835 macaddr
=> get_standard_option
('mac-addr', {
836 description
=> "MAC address. That address must be unique withing your network. This is automatically generated if not specified.",
840 description
=> "Network Card Model. The 'virtio' model provides the best performance with very low CPU overhead. If your guest does not support this driver, it is usually best to use 'e1000'.",
841 enum
=> $nic_model_list,
844 (map { $_ => { keyAlias
=> 'model', alias
=> 'macaddr' }} @$nic_model_list),
847 description
=> $net_fmt_bridge_descr,
848 format_description
=> 'bridge',
849 pattern
=> '[-_.\w\d]+',
854 minimum
=> 0, maximum
=> 16,
855 description
=> 'Number of packet queues to be used on the device.',
861 description
=> "Rate limit in mbps (megabytes per second) as floating point number.",
866 minimum
=> 1, maximum
=> 4094,
867 description
=> 'VLAN tag to apply to packets on this interface.',
872 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
873 description
=> 'VLAN trunks to pass through this interface.',
874 format_description
=> 'vlanid[;vlanid...]',
879 description
=> 'Whether this interface should be protected by the firewall.',
884 description
=> 'Whether this interface should be disconnected (like pulling the plug).',
891 type
=> 'string', format
=> $net_fmt,
892 description
=> "Specify network devices.",
895 PVE
::JSONSchema
::register_standard_option
("pve-qm-net", $netdesc);
900 format
=> 'pve-ipv4-config',
901 format_description
=> 'IPv4Format/CIDR',
902 description
=> 'IPv4 address in CIDR format.',
909 format_description
=> 'GatewayIPv4',
910 description
=> 'Default gateway for IPv4 traffic.',
916 format
=> 'pve-ipv6-config',
917 format_description
=> 'IPv6Format/CIDR',
918 description
=> 'IPv6 address in CIDR format.',
925 format_description
=> 'GatewayIPv6',
926 description
=> 'Default gateway for IPv6 traffic.',
931 PVE
::JSONSchema
::register_format
('pve-qm-ipconfig', $ipconfig_fmt);
934 type
=> 'string', format
=> 'pve-qm-ipconfig',
935 description
=> <<'EODESCR',
936 cloud-init: Specify IP addresses and gateways for the corresponding interface.
938 IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
940 The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit gateway should be provided.
941 For IPv6 the special string 'auto' can be used to use stateless autoconfiguration.
943 If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using dhcp on IPv4.
946 PVE
::JSONSchema
::register_standard_option
("pve-qm-ipconfig", $netdesc);
948 for (my $i = 0; $i < $MAX_NETS; $i++) {
949 $confdesc->{"net$i"} = $netdesc;
950 $confdesc_cloudinit->{"ipconfig$i"} = $ipconfigdesc;
953 foreach my $key (keys %$confdesc_cloudinit) {
954 $confdesc->{$key} = $confdesc_cloudinit->{$key};
957 PVE
::JSONSchema
::register_format
('pve-volume-id-or-qm-path', \
&verify_volume_id_or_qm_path
);
958 sub verify_volume_id_or_qm_path
{
959 my ($volid, $noerr) = @_;
961 if ($volid eq 'none' || $volid eq 'cdrom' || $volid =~ m
|^/|) {
965 # if its neither 'none' nor 'cdrom' nor a path, check if its a volume-id
966 $volid = eval { PVE
::JSONSchema
::check_format
('pve-volume-id', $volid, '') };
968 return undef if $noerr;
977 type
=> 'string', format
=> 'pve-qm-usb-device',
978 format_description
=> 'HOSTUSBDEVICE|spice',
979 description
=> <<EODESCR,
980 The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
982 'bus-port(.port)*' (decimal numbers) or
983 'vendor_id:product_id' (hexadeciaml numbers) or
986 You can use the 'lsusb -t' command to list existing usb devices.
988 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such machines - use with special care.
990 The value 'spice' can be used to add a usb redirection devices for spice.
996 description
=> "Specifies whether if given host option is a USB3 device or port.",
1003 type
=> 'string', format
=> $usb_fmt,
1004 description
=> "Configure an USB device (n is 0 to 4).",
1006 PVE
::JSONSchema
::register_standard_option
("pve-qm-usb", $usbdesc);
1008 my $PCIRE = qr/([a-f0-9]{4}:)?[a-f0-9]{2}:[a-f0-9]{2}(?:\.[a-f0-9])?/;
1013 pattern
=> qr/$PCIRE(;$PCIRE)*/,
1014 format_description
=> 'HOSTPCIID[;HOSTPCIID2...]',
1015 description
=> <<EODESCR,
1016 Host PCI device pass through. The PCI ID of a host's PCI device or a list
1017 of PCI virtual functions of the host. HOSTPCIID syntax is:
1019 'bus:dev.func' (hexadecimal numbers)
1021 You can us the 'lspci' command to list existing PCI devices.
1026 description
=> "Specify whether or not the device's ROM will be visible in the guest's memory map.",
1032 pattern
=> '[^,;]+',
1033 format_description
=> 'string',
1034 description
=> "Custom pci device rom filename (must be located in /usr/share/kvm/).",
1039 description
=> "Choose the PCI-express bus (needs the 'q35' machine model).",
1045 description
=> "Enable vfio-vga device support.",
1051 format_description
=> 'string',
1052 pattern
=> '[^/\.:]+',
1054 description
=> <<EODESCR
1055 The type of mediated device to use.
1056 An instance of this type will be created on startup of the VM and
1057 will be cleaned up when the VM stops.
1061 PVE
::JSONSchema
::register_format
('pve-qm-hostpci', $hostpci_fmt);
1065 type
=> 'string', format
=> 'pve-qm-hostpci',
1066 description
=> "Map host PCI devices into guest.",
1067 verbose_description
=> <<EODESCR,
1068 Map host PCI devices into guest.
1070 NOTE: This option allows direct access to host hardware. So it is no longer
1071 possible to migrate such machines - use with special care.
1073 CAUTION: Experimental! User reported problems with this option.
1076 PVE
::JSONSchema
::register_standard_option
("pve-qm-hostpci", $hostpcidesc);
1081 pattern
=> '(/dev/.+|socket)',
1082 description
=> "Create a serial device inside the VM (n is 0 to 3)",
1083 verbose_description
=> <<EODESCR,
1084 Create a serial device inside the VM (n is 0 to 3), and pass through a
1085 host serial device (i.e. /dev/ttyS0), or create a unix socket on the
1086 host side (use 'qm terminal' to open a terminal connection).
1088 NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines - use with special care.
1090 CAUTION: Experimental! User reported problems with this option.
1097 pattern
=> '/dev/parport\d+|/dev/usb/lp\d+',
1098 description
=> "Map host parallel devices (n is 0 to 2).",
1099 verbose_description
=> <<EODESCR,
1100 Map host parallel devices (n is 0 to 2).
1102 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such machines - use with special care.
1104 CAUTION: Experimental! User reported problems with this option.
1108 for (my $i = 0; $i < $MAX_PARALLEL_PORTS; $i++) {
1109 $confdesc->{"parallel$i"} = $paralleldesc;
1112 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
1113 $confdesc->{"serial$i"} = $serialdesc;
1116 for (my $i = 0; $i < $MAX_HOSTPCI_DEVICES; $i++) {
1117 $confdesc->{"hostpci$i"} = $hostpcidesc;
1120 for my $key (keys %{$PVE::QemuServer
::Drive
::drivedesc_hash
}) {
1121 $confdesc->{$key} = $PVE::QemuServer
::Drive
::drivedesc_hash-
>{$key};
1124 for (my $i = 0; $i < $MAX_USB_DEVICES; $i++) {
1125 $confdesc->{"usb$i"} = $usbdesc;
1128 my $kvm_api_version = 0;
1131 return $kvm_api_version if $kvm_api_version;
1133 open my $fh, '<', '/dev/kvm'
1136 # 0xae00 => KVM_GET_API_VERSION
1137 $kvm_api_version = ioctl($fh, 0xae00, 0);
1139 return $kvm_api_version;
1142 my $kvm_user_version = {};
1145 sub kvm_user_version
{
1148 $binary //= get_command_for_arch
(get_host_arch
()); # get the native arch by default
1149 my $st = stat($binary);
1151 my $cachedmtime = $kvm_mtime->{$binary} // -1;
1152 return $kvm_user_version->{$binary} if $kvm_user_version->{$binary} &&
1153 $cachedmtime == $st->mtime;
1155 $kvm_user_version->{$binary} = 'unknown';
1156 $kvm_mtime->{$binary} = $st->mtime;
1160 if ($line =~ m/^QEMU( PC)? emulator version (\d+\.\d+(\.\d+)?)(\.\d+)?[,\s]/) {
1161 $kvm_user_version->{$binary} = $2;
1165 eval { run_command
([$binary, '--version'], outfunc
=> $code); };
1168 return $kvm_user_version->{$binary};
1172 sub kernel_has_vhost_net
{
1173 return -c
'/dev/vhost-net';
1178 return defined($confdesc->{$key});
1182 sub get_cdrom_path
{
1184 return $cdrom_path if $cdrom_path;
1186 return $cdrom_path = "/dev/cdrom" if -l
"/dev/cdrom";
1187 return $cdrom_path = "/dev/cdrom1" if -l
"/dev/cdrom1";
1188 return $cdrom_path = "/dev/cdrom2" if -l
"/dev/cdrom2";
1192 my ($storecfg, $vmid, $cdrom) = @_;
1194 if ($cdrom eq 'cdrom') {
1195 return get_cdrom_path
();
1196 } elsif ($cdrom eq 'none') {
1198 } elsif ($cdrom =~ m
|^/|) {
1201 return PVE
::Storage
::path
($storecfg, $cdrom);
1205 # try to convert old style file names to volume IDs
1206 sub filename_to_volume_id
{
1207 my ($vmid, $file, $media) = @_;
1209 if (!($file eq 'none' || $file eq 'cdrom' ||
1210 $file =~ m
|^/dev/.+| || $file =~ m/^([^:]+):(.+)$/)) {
1212 return undef if $file =~ m
|/|;
1214 if ($media && $media eq 'cdrom') {
1215 $file = "local:iso/$file";
1217 $file = "local:$vmid/$file";
1224 sub verify_media_type
{
1225 my ($opt, $vtype, $media) = @_;
1230 if ($media eq 'disk') {
1232 } elsif ($media eq 'cdrom') {
1235 die "internal error";
1238 return if ($vtype eq $etype);
1240 raise_param_exc
({ $opt => "unexpected media type ($vtype != $etype)" });
1243 sub cleanup_drive_path
{
1244 my ($opt, $storecfg, $drive) = @_;
1246 # try to convert filesystem paths to volume IDs
1248 if (($drive->{file
} !~ m/^(cdrom|none)$/) &&
1249 ($drive->{file
} !~ m
|^/dev/.+|) &&
1250 ($drive->{file
} !~ m/^([^:]+):(.+)$/) &&
1251 ($drive->{file
} !~ m/^\d+$/)) {
1252 my ($vtype, $volid) = PVE
::Storage
::path_to_volume_id
($storecfg, $drive->{file
});
1253 raise_param_exc
({ $opt => "unable to associate path '$drive->{file}' to any storage"}) if !$vtype;
1254 $drive->{media
} = 'cdrom' if !$drive->{media
} && $vtype eq 'iso';
1255 verify_media_type
($opt, $vtype, $drive->{media
});
1256 $drive->{file
} = $volid;
1259 $drive->{media
} = 'cdrom' if !$drive->{media
} && $drive->{file
} =~ m/^(cdrom|none)$/;
1262 sub parse_hotplug_features
{
1267 return $res if $data eq '0';
1269 $data = $confdesc->{hotplug
}->{default} if $data eq '1';
1271 foreach my $feature (PVE
::Tools
::split_list
($data)) {
1272 if ($feature =~ m/^(network|disk|cpu|memory|usb)$/) {
1275 die "invalid hotplug feature '$feature'\n";
1281 PVE
::JSONSchema
::register_format
('pve-hotplug-features', \
&pve_verify_hotplug_features
);
1282 sub pve_verify_hotplug_features
{
1283 my ($value, $noerr) = @_;
1285 return $value if parse_hotplug_features
($value);
1287 return undef if $noerr;
1289 die "unable to parse hotplug option\n";
1293 my($fh, $noerr) = @_;
1296 my $SG_GET_VERSION_NUM = 0x2282;
1298 my $versionbuf = "\x00" x
8;
1299 my $ret = ioctl($fh, $SG_GET_VERSION_NUM, $versionbuf);
1301 die "scsi ioctl SG_GET_VERSION_NUM failoed - $!\n" if !$noerr;
1304 my $version = unpack("I", $versionbuf);
1305 if ($version < 30000) {
1306 die "scsi generic interface too old\n" if !$noerr;
1310 my $buf = "\x00" x
36;
1311 my $sensebuf = "\x00" x
8;
1312 my $cmd = pack("C x3 C x1", 0x12, 36);
1314 # see /usr/include/scsi/sg.h
1315 my $sg_io_hdr_t = "i i C C s I P P P I I i P C C C C S S i I I";
1317 my $packet = pack($sg_io_hdr_t, ord('S'), -3, length($cmd),
1318 length($sensebuf), 0, length($buf), $buf,
1319 $cmd, $sensebuf, 6000);
1321 $ret = ioctl($fh, $SG_IO, $packet);
1323 die "scsi ioctl SG_IO failed - $!\n" if !$noerr;
1327 my @res = unpack($sg_io_hdr_t, $packet);
1328 if ($res[17] || $res[18]) {
1329 die "scsi ioctl SG_IO status error - $!\n" if !$noerr;
1334 (my $byte0, my $byte1, $res->{vendor
},
1335 $res->{product
}, $res->{revision
}) = unpack("C C x6 A8 A16 A4", $buf);
1337 $res->{removable
} = $byte1 & 128 ?
1 : 0;
1338 $res->{type
} = $byte0 & 31;
1346 my $fh = IO
::File-
>new("+<$path") || return undef;
1347 my $res = scsi_inquiry
($fh, 1);
1353 sub print_tabletdevice_full
{
1354 my ($conf, $arch) = @_;
1356 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
1358 # we use uhci for old VMs because tablet driver was buggy in older qemu
1360 if (PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf) || $arch eq 'aarch64') {
1366 return "usb-tablet,id=tablet,bus=$usbbus.0,port=1";
1369 sub print_keyboarddevice_full
{
1370 my ($conf, $arch, $machine) = @_;
1372 return undef if $arch ne 'aarch64';
1374 return "usb-kbd,id=keyboard,bus=ehci.0,port=2";
1377 sub print_drivedevice_full
{
1378 my ($storecfg, $conf, $vmid, $drive, $bridges, $arch, $machine_type) = @_;
1383 if ($drive->{interface
} eq 'virtio') {
1384 my $pciaddr = print_pci_addr
("$drive->{interface}$drive->{index}", $bridges, $arch, $machine_type);
1385 $device = "virtio-blk-pci,drive=drive-$drive->{interface}$drive->{index},id=$drive->{interface}$drive->{index}$pciaddr";
1386 $device .= ",iothread=iothread-$drive->{interface}$drive->{index}" if $drive->{iothread
};
1387 } elsif ($drive->{interface
} eq 'scsi') {
1389 my ($maxdev, $controller, $controller_prefix) = scsihw_infos
($conf, $drive);
1390 my $unit = $drive->{index} % $maxdev;
1391 my $devicetype = 'hd';
1393 if (drive_is_cdrom
($drive)) {
1396 if ($drive->{file
} =~ m
|^/|) {
1397 $path = $drive->{file
};
1398 if (my $info = path_is_scsi
($path)) {
1399 if ($info->{type
} == 0 && $drive->{scsiblock
}) {
1400 $devicetype = 'block';
1401 } elsif ($info->{type
} == 1) { # tape
1402 $devicetype = 'generic';
1406 $path = PVE
::Storage
::path
($storecfg, $drive->{file
});
1409 # for compatibility only, we prefer scsi-hd (#2408, #2355, #2380)
1410 my $version = PVE
::QemuServer
::Machine
::extract_version
($machine_type, kvm_user_version
());
1411 if ($path =~ m/^iscsi\:\/\
// &&
1412 !min_version
($version, 4, 1)) {
1413 $devicetype = 'generic';
1417 if (!$conf->{scsihw
} || ($conf->{scsihw
} =~ m/^lsi/)){
1418 $device = "scsi-$devicetype,bus=$controller_prefix$controller.0,scsi-id=$unit,drive=drive-$drive->{interface}$drive->{index},id=$drive->{interface}$drive->{index}";
1420 $device = "scsi-$devicetype,bus=$controller_prefix$controller.0,channel=0,scsi-id=0,lun=$drive->{index},drive=drive-$drive->{interface}$drive->{index},id=$drive->{interface}$drive->{index}";
1423 if ($drive->{ssd
} && ($devicetype eq 'block' || $devicetype eq 'hd')) {
1424 $device .= ",rotation_rate=1";
1426 $device .= ",wwn=$drive->{wwn}" if $drive->{wwn
};
1428 } elsif ($drive->{interface
} eq 'ide' || $drive->{interface
} eq 'sata') {
1429 my $maxdev = ($drive->{interface
} eq 'sata') ?
$PVE::QemuServer
::Drive
::MAX_SATA_DISKS
: 2;
1430 my $controller = int($drive->{index} / $maxdev);
1431 my $unit = $drive->{index} % $maxdev;
1432 my $devicetype = ($drive->{media
} && $drive->{media
} eq 'cdrom') ?
"cd" : "hd";
1434 $device = "ide-$devicetype";
1435 if ($drive->{interface
} eq 'ide') {
1436 $device .= ",bus=ide.$controller,unit=$unit";
1438 $device .= ",bus=ahci$controller.$unit";
1440 $device .= ",drive=drive-$drive->{interface}$drive->{index},id=$drive->{interface}$drive->{index}";
1442 if ($devicetype eq 'hd') {
1443 if (my $model = $drive->{model
}) {
1444 $model = URI
::Escape
::uri_unescape
($model);
1445 $device .= ",model=$model";
1447 if ($drive->{ssd
}) {
1448 $device .= ",rotation_rate=1";
1451 $device .= ",wwn=$drive->{wwn}" if $drive->{wwn
};
1452 } elsif ($drive->{interface
} eq 'usb') {
1454 # -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0
1456 die "unsupported interface type";
1459 $device .= ",bootindex=$drive->{bootindex}" if $drive->{bootindex
};
1461 if (my $serial = $drive->{serial
}) {
1462 $serial = URI
::Escape
::uri_unescape
($serial);
1463 $device .= ",serial=$serial";
1470 sub get_initiator_name
{
1473 my $fh = IO
::File-
>new('/etc/iscsi/initiatorname.iscsi') || return undef;
1474 while (defined(my $line = <$fh>)) {
1475 next if $line !~ m/^\s*InitiatorName\s*=\s*([\.\-:\w]+)/;
1484 sub print_drive_commandline_full
{
1485 my ($storecfg, $vmid, $drive) = @_;
1488 my $volid = $drive->{file
};
1491 if (drive_is_cdrom
($drive)) {
1492 $path = get_iso_path
($storecfg, $vmid, $volid);
1494 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
1496 $path = PVE
::Storage
::path
($storecfg, $volid);
1497 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
1498 $format = qemu_img_format
($scfg, $volname);
1506 my @qemu_drive_options = qw(heads secs cyls trans media format cache rerror werror aio discard);
1507 foreach my $o (@qemu_drive_options) {
1508 $opts .= ",$o=$drive->{$o}" if defined($drive->{$o});
1511 # snapshot only accepts on|off
1512 if (defined($drive->{snapshot
})) {
1513 my $v = $drive->{snapshot
} ?
'on' : 'off';
1514 $opts .= ",snapshot=$v";
1517 foreach my $type (['', '-total'], [_rd
=> '-read'], [_wr
=> '-write']) {
1518 my ($dir, $qmpname) = @$type;
1519 if (my $v = $drive->{"mbps$dir"}) {
1520 $opts .= ",throttling.bps$qmpname=".int($v*1024*1024);
1522 if (my $v = $drive->{"mbps${dir}_max"}) {
1523 $opts .= ",throttling.bps$qmpname-max=".int($v*1024*1024);
1525 if (my $v = $drive->{"bps${dir}_max_length"}) {
1526 $opts .= ",throttling.bps$qmpname-max-length=$v";
1528 if (my $v = $drive->{"iops${dir}"}) {
1529 $opts .= ",throttling.iops$qmpname=$v";
1531 if (my $v = $drive->{"iops${dir}_max"}) {
1532 $opts .= ",throttling.iops$qmpname-max=$v";
1534 if (my $v = $drive->{"iops${dir}_max_length"}) {
1535 $opts .= ",throttling.iops$qmpname-max-length=$v";
1539 $opts .= ",format=$format" if $format && !$drive->{format
};
1541 my $cache_direct = 0;
1543 if (my $cache = $drive->{cache
}) {
1544 $cache_direct = $cache =~ /^(?:off|none|directsync)$/;
1545 } elsif (!drive_is_cdrom
($drive)) {
1546 $opts .= ",cache=none";
1550 # aio native works only with O_DIRECT
1551 if (!$drive->{aio
}) {
1553 $opts .= ",aio=native";
1555 $opts .= ",aio=threads";
1559 if (!drive_is_cdrom
($drive)) {
1561 if (defined($drive->{detect_zeroes
}) && !$drive->{detect_zeroes
}) {
1562 $detectzeroes = 'off';
1563 } elsif ($drive->{discard
}) {
1564 $detectzeroes = $drive->{discard
} eq 'on' ?
'unmap' : 'on';
1566 # This used to be our default with discard not being specified:
1567 $detectzeroes = 'on';
1569 $opts .= ",detect-zeroes=$detectzeroes" if $detectzeroes;
1572 my $pathinfo = $path ?
"file=$path," : '';
1574 return "${pathinfo}if=none,id=drive-$drive->{interface}$drive->{index}$opts";
1577 sub print_netdevice_full
{
1578 my ($vmid, $conf, $net, $netid, $bridges, $use_old_bios_files, $arch, $machine_type) = @_;
1580 my $bootorder = $conf->{boot
} || $confdesc->{boot
}->{default};
1582 my $device = $net->{model
};
1583 if ($net->{model
} eq 'virtio') {
1584 $device = 'virtio-net-pci';
1587 my $pciaddr = print_pci_addr
("$netid", $bridges, $arch, $machine_type);
1588 my $tmpstr = "$device,mac=$net->{macaddr},netdev=$netid$pciaddr,id=$netid";
1589 if ($net->{queues
} && $net->{queues
} > 1 && $net->{model
} eq 'virtio'){
1590 #Consider we have N queues, the number of vectors needed is 2*N + 2 (plus one config interrupt and control vq)
1591 my $vectors = $net->{queues
} * 2 + 2;
1592 $tmpstr .= ",vectors=$vectors,mq=on";
1594 $tmpstr .= ",bootindex=$net->{bootindex}" if $net->{bootindex
} ;
1596 if ($use_old_bios_files) {
1598 if ($device eq 'virtio-net-pci') {
1599 $romfile = 'pxe-virtio.rom';
1600 } elsif ($device eq 'e1000') {
1601 $romfile = 'pxe-e1000.rom';
1602 } elsif ($device eq 'ne2k') {
1603 $romfile = 'pxe-ne2k_pci.rom';
1604 } elsif ($device eq 'pcnet') {
1605 $romfile = 'pxe-pcnet.rom';
1606 } elsif ($device eq 'rtl8139') {
1607 $romfile = 'pxe-rtl8139.rom';
1609 $tmpstr .= ",romfile=$romfile" if $romfile;
1615 sub print_netdev_full
{
1616 my ($vmid, $conf, $arch, $net, $netid, $hotplug) = @_;
1619 if ($netid =~ m/^net(\d+)$/) {
1623 die "got strange net id '$i'\n" if $i >= ${MAX_NETS
};
1625 my $ifname = "tap${vmid}i$i";
1627 # kvm uses TUNSETIFF ioctl, and that limits ifname length
1628 die "interface name '$ifname' is too long (max 15 character)\n"
1629 if length($ifname) >= 16;
1631 my $vhostparam = '';
1632 if (is_native
($arch)) {
1633 $vhostparam = ',vhost=on' if kernel_has_vhost_net
() && $net->{model
} eq 'virtio';
1636 my $vmname = $conf->{name
} || "vm$vmid";
1639 my $script = $hotplug ?
"pve-bridge-hotplug" : "pve-bridge";
1641 if ($net->{bridge
}) {
1642 $netdev = "type=tap,id=$netid,ifname=${ifname},script=/var/lib/qemu-server/$script,downscript=/var/lib/qemu-server/pve-bridgedown$vhostparam";
1644 $netdev = "type=user,id=$netid,hostname=$vmname";
1647 $netdev .= ",queues=$net->{queues}" if ($net->{queues
} && $net->{model
} eq 'virtio');
1653 'cirrus' => 'cirrus-vga',
1655 'vmware' => 'vmware-svga',
1656 'virtio' => 'virtio-vga',
1659 sub print_vga_device
{
1660 my ($conf, $vga, $arch, $machine_version, $machine, $id, $qxlnum, $bridges) = @_;
1662 my $type = $vga_map->{$vga->{type
}};
1663 if ($arch eq 'aarch64' && defined($type) && $type eq 'virtio-vga') {
1664 $type = 'virtio-gpu';
1666 my $vgamem_mb = $vga->{memory
};
1668 my $max_outputs = '';
1670 $type = $id ?
'qxl' : 'qxl-vga';
1672 if (!$conf->{ostype
} || $conf->{ostype
} =~ m/^(?:l\d\d)|(?:other)$/) {
1673 # set max outputs so linux can have up to 4 qxl displays with one device
1674 if (min_version
($machine_version, 4, 1)) {
1675 $max_outputs = ",max_outputs=4";
1680 die "no devicetype for $vga->{type}\n" if !$type;
1684 if ($vga->{type
} eq 'virtio') {
1685 my $bytes = PVE
::Tools
::convert_size
($vgamem_mb, "mb" => "b");
1686 $memory = ",max_hostmem=$bytes";
1688 # from https://www.spice-space.org/multiple-monitors.html
1689 $memory = ",vgamem_mb=$vga->{memory}";
1690 my $ram = $vgamem_mb * 4;
1691 my $vram = $vgamem_mb * 2;
1692 $memory .= ",ram_size_mb=$ram,vram_size_mb=$vram";
1694 $memory = ",vgamem_mb=$vga->{memory}";
1696 } elsif ($qxlnum && $id) {
1697 $memory = ",ram_size=67108864,vram_size=33554432";
1700 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
1701 my $vgaid = "vga" . ($id // '');
1704 if ($q35 && $vgaid eq 'vga') {
1705 # the first display uses pcie.0 bus on q35 machines
1706 $pciaddr = print_pcie_addr
($vgaid, $bridges, $arch, $machine);
1708 $pciaddr = print_pci_addr
($vgaid, $bridges, $arch, $machine);
1711 return "$type,id=${vgaid}${memory}${max_outputs}${pciaddr}";
1714 sub parse_number_sets
{
1717 foreach my $part (split(/;/, $set)) {
1718 if ($part =~ /^\s*(\d+)(?:-(\d+))?\s*$/) {
1719 die "invalid range: $part ($2 < $1)\n" if defined($2) && $2 < $1;
1720 push @$res, [ $1, $2 ];
1722 die "invalid range: $part\n";
1731 my $res = PVE
::JSONSchema
::parse_property_string
($numa_fmt, $data);
1732 $res->{cpus
} = parse_number_sets
($res->{cpus
}) if defined($res->{cpus
});
1733 $res->{hostnodes
} = parse_number_sets
($res->{hostnodes
}) if defined($res->{hostnodes
});
1740 return undef if !$value;
1742 my $res = PVE
::JSONSchema
::parse_property_string
($hostpci_fmt, $value);
1744 my @idlist = split(/;/, $res->{host
});
1745 delete $res->{host
};
1746 foreach my $id (@idlist) {
1747 my $devs = PVE
::SysFSTools
::lspci
($id);
1748 die "no PCI device found for '$id'\n" if !scalar(@$devs);
1749 push @{$res->{pciid
}}, @$devs;
1754 # netX: e1000=XX:XX:XX:XX:XX:XX,bridge=vmbr0,rate=<mbps>
1758 my $res = eval { PVE
::JSONSchema
::parse_property_string
($net_fmt, $data) };
1763 if (!defined($res->{macaddr
})) {
1764 my $dc = PVE
::Cluster
::cfs_read_file
('datacenter.cfg');
1765 $res->{macaddr
} = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
});
1770 # ipconfigX ip=cidr,gw=ip,ip6=cidr,gw6=ip
1771 sub parse_ipconfig
{
1774 my $res = eval { PVE
::JSONSchema
::parse_property_string
($ipconfig_fmt, $data) };
1780 if ($res->{gw
} && !$res->{ip
}) {
1781 warn 'gateway specified without specifying an IP address';
1784 if ($res->{gw6
} && !$res->{ip6
}) {
1785 warn 'IPv6 gateway specified without specifying an IPv6 address';
1788 if ($res->{gw
} && $res->{ip
} eq 'dhcp') {
1789 warn 'gateway specified together with DHCP';
1792 if ($res->{gw6
} && $res->{ip6
} !~ /^$IPV6RE/) {
1794 warn "IPv6 gateway specified together with $res->{ip6} address";
1798 if (!$res->{ip
} && !$res->{ip6
}) {
1799 return { ip
=> 'dhcp', ip6
=> 'dhcp' };
1808 return PVE
::JSONSchema
::print_property_string
($net, $net_fmt);
1811 sub add_random_macs
{
1812 my ($settings) = @_;
1814 foreach my $opt (keys %$settings) {
1815 next if $opt !~ m/^net(\d+)$/;
1816 my $net = parse_net
($settings->{$opt});
1818 $settings->{$opt} = print_net
($net);
1822 sub vm_is_volid_owner
{
1823 my ($storecfg, $vmid, $volid) = @_;
1825 if ($volid !~ m
|^/|) {
1827 eval { ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid); };
1828 if ($owner && ($owner == $vmid)) {
1836 sub vmconfig_register_unused_drive
{
1837 my ($storecfg, $vmid, $conf, $drive) = @_;
1839 if (drive_is_cloudinit
($drive)) {
1840 eval { PVE
::Storage
::vdisk_free
($storecfg, $drive->{file
}) };
1842 } elsif (!drive_is_cdrom
($drive)) {
1843 my $volid = $drive->{file
};
1844 if (vm_is_volid_owner
($storecfg, $vmid, $volid)) {
1845 PVE
::QemuConfig-
>add_unused_volume($conf, $volid, $vmid);
1850 # smbios: [manufacturer=str][,product=str][,version=str][,serial=str][,uuid=uuid][,sku=str][,family=str][,base64=bool]
1854 pattern
=> '[a-fA-F0-9]{8}(?:-[a-fA-F0-9]{4}){3}-[a-fA-F0-9]{12}',
1855 format_description
=> 'UUID',
1856 description
=> "Set SMBIOS1 UUID.",
1861 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1862 format_description
=> 'Base64 encoded string',
1863 description
=> "Set SMBIOS1 version.",
1868 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1869 format_description
=> 'Base64 encoded string',
1870 description
=> "Set SMBIOS1 serial number.",
1875 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1876 format_description
=> 'Base64 encoded string',
1877 description
=> "Set SMBIOS1 manufacturer.",
1882 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1883 format_description
=> 'Base64 encoded string',
1884 description
=> "Set SMBIOS1 product ID.",
1889 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1890 format_description
=> 'Base64 encoded string',
1891 description
=> "Set SMBIOS1 SKU string.",
1896 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1897 format_description
=> 'Base64 encoded string',
1898 description
=> "Set SMBIOS1 family string.",
1903 description
=> 'Flag to indicate that the SMBIOS values are base64 encoded',
1911 my $res = eval { PVE
::JSONSchema
::parse_property_string
($smbios1_fmt, $data) };
1918 return PVE
::JSONSchema
::print_property_string
($smbios1, $smbios1_fmt);
1921 PVE
::JSONSchema
::register_format
('pve-qm-smbios1', $smbios1_fmt);
1923 sub parse_watchdog
{
1926 return undef if !$value;
1928 my $res = eval { PVE
::JSONSchema
::parse_property_string
($watchdog_fmt, $value) };
1933 sub parse_guest_agent
{
1936 return {} if !defined($value->{agent
});
1938 my $res = eval { PVE
::JSONSchema
::parse_property_string
($agent_fmt, $value->{agent
}) };
1941 # if the agent is disabled ignore the other potentially set properties
1942 return {} if !$res->{enabled
};
1949 return {} if !$value;
1950 my $res = eval { PVE
::JSONSchema
::parse_property_string
($vga_fmt, $value) };
1958 return undef if !$value;
1960 my $res = eval { PVE
::JSONSchema
::parse_property_string
($rng_fmt, $value) };
1965 PVE
::JSONSchema
::register_format
('pve-qm-usb-device', \
&verify_usb_device
);
1966 sub verify_usb_device
{
1967 my ($value, $noerr) = @_;
1969 return $value if parse_usb_device
($value);
1971 return undef if $noerr;
1973 die "unable to parse usb device\n";
1976 # add JSON properties for create and set function
1977 sub json_config_properties
{
1980 foreach my $opt (keys %$confdesc) {
1981 next if $opt eq 'parent' || $opt eq 'snaptime' || $opt eq 'vmstate' ||
1982 $opt eq 'runningmachine' || $opt eq 'runningcpu';
1983 $prop->{$opt} = $confdesc->{$opt};
1989 # return copy of $confdesc_cloudinit to generate documentation
1990 sub cloudinit_config_properties
{
1992 return dclone
($confdesc_cloudinit);
1996 my ($key, $value) = @_;
1998 die "unknown setting '$key'\n" if !$confdesc->{$key};
2000 my $type = $confdesc->{$key}->{type
};
2002 if (!defined($value)) {
2003 die "got undefined value\n";
2006 if ($value =~ m/[\n\r]/) {
2007 die "property contains a line feed\n";
2010 if ($type eq 'boolean') {
2011 return 1 if ($value eq '1') || ($value =~ m/^(on|yes|true)$/i);
2012 return 0 if ($value eq '0') || ($value =~ m/^(off|no|false)$/i);
2013 die "type check ('boolean') failed - got '$value'\n";
2014 } elsif ($type eq 'integer') {
2015 return int($1) if $value =~ m/^(\d+)$/;
2016 die "type check ('integer') failed - got '$value'\n";
2017 } elsif ($type eq 'number') {
2018 return $value if $value =~ m/^(\d+)(\.\d+)?$/;
2019 die "type check ('number') failed - got '$value'\n";
2020 } elsif ($type eq 'string') {
2021 if (my $fmt = $confdesc->{$key}->{format
}) {
2022 PVE
::JSONSchema
::check_format
($fmt, $value);
2025 $value =~ s/^\"(.*)\"$/$1/;
2028 die "internal error"
2033 my ($storecfg, $vmid, $skiplock, $replacement_conf) = @_;
2035 my $conf = PVE
::QemuConfig-
>load_config($vmid);
2037 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
2039 if ($conf->{template
}) {
2040 # check if any base image is still used by a linked clone
2041 foreach_drive
($conf, sub {
2042 my ($ds, $drive) = @_;
2043 return if drive_is_cdrom
($drive);
2045 my $volid = $drive->{file
};
2046 return if !$volid || $volid =~ m
|^/|;
2048 die "base volume '$volid' is still in use by linked cloned\n"
2049 if PVE
::Storage
::volume_is_base_and_used
($storecfg, $volid);
2054 # only remove disks owned by this VM
2055 foreach_drive
($conf, sub {
2056 my ($ds, $drive) = @_;
2057 return if drive_is_cdrom
($drive, 1);
2059 my $volid = $drive->{file
};
2060 return if !$volid || $volid =~ m
|^/|;
2062 my ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid);
2063 return if !$path || !$owner || ($owner != $vmid);
2065 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid) };
2066 warn "Could not remove disk '$volid', check manually: $@" if $@;
2069 # also remove unused disk
2070 my $vmdisks = PVE
::Storage
::vdisk_list
($storecfg, undef, $vmid);
2071 PVE
::Storage
::foreach_volid
($vmdisks, sub {
2072 my ($volid, $sid, $volname, $d) = @_;
2073 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid) };
2077 if (defined $replacement_conf) {
2078 PVE
::QemuConfig-
>write_config($vmid, $replacement_conf);
2080 PVE
::QemuConfig-
>destroy_config($vmid);
2084 sub parse_vm_config
{
2085 my ($filename, $raw) = @_;
2087 return undef if !defined($raw);
2090 digest
=> Digest
::SHA
::sha1_hex
($raw),
2095 $filename =~ m
|/qemu-server/(\d
+)\
.conf
$|
2096 || die "got strange filename '$filename'";
2104 my @lines = split(/\n/, $raw);
2105 foreach my $line (@lines) {
2106 next if $line =~ m/^\s*$/;
2108 if ($line =~ m/^\[PENDING\]\s*$/i) {
2109 $section = 'pending';
2110 if (defined($descr)) {
2112 $conf->{description
} = $descr;
2115 $conf = $res->{$section} = {};
2118 } elsif ($line =~ m/^\[([a-z][a-z0-9_\-]+)\]\s*$/i) {
2120 if (defined($descr)) {
2122 $conf->{description
} = $descr;
2125 $conf = $res->{snapshots
}->{$section} = {};
2129 if ($line =~ m/^\#(.*)\s*$/) {
2130 $descr = '' if !defined($descr);
2131 $descr .= PVE
::Tools
::decode_text
($1) . "\n";
2135 if ($line =~ m/^(description):\s*(.*\S)\s*$/) {
2136 $descr = '' if !defined($descr);
2137 $descr .= PVE
::Tools
::decode_text
($2);
2138 } elsif ($line =~ m/snapstate:\s*(prepare|delete)\s*$/) {
2139 $conf->{snapstate
} = $1;
2140 } elsif ($line =~ m/^(args):\s*(.*\S)\s*$/) {
2143 $conf->{$key} = $value;
2144 } elsif ($line =~ m/^delete:\s*(.*\S)\s*$/) {
2146 if ($section eq 'pending') {
2147 $conf->{delete} = $value; # we parse this later
2149 warn "vm $vmid - propertry 'delete' is only allowed in [PENDING]\n";
2151 } elsif ($line =~ m/^([a-z][a-z_]*\d*):\s*(.+?)\s*$/) {
2154 eval { $value = check_type
($key, $value); };
2156 warn "vm $vmid - unable to parse value of '$key' - $@";
2158 $key = 'ide2' if $key eq 'cdrom';
2159 my $fmt = $confdesc->{$key}->{format
};
2160 if ($fmt && $fmt =~ /^pve-qm-(?:ide|scsi|virtio|sata)$/) {
2161 my $v = parse_drive
($key, $value);
2162 if (my $volid = filename_to_volume_id
($vmid, $v->{file
}, $v->{media
})) {
2163 $v->{file
} = $volid;
2164 $value = print_drive
($v);
2166 warn "vm $vmid - unable to parse value of '$key'\n";
2171 $conf->{$key} = $value;
2176 if (defined($descr)) {
2178 $conf->{description
} = $descr;
2180 delete $res->{snapstate
}; # just to be sure
2185 sub write_vm_config
{
2186 my ($filename, $conf) = @_;
2188 delete $conf->{snapstate
}; # just to be sure
2190 if ($conf->{cdrom
}) {
2191 die "option ide2 conflicts with cdrom\n" if $conf->{ide2
};
2192 $conf->{ide2
} = $conf->{cdrom
};
2193 delete $conf->{cdrom
};
2196 # we do not use 'smp' any longer
2197 if ($conf->{sockets
}) {
2198 delete $conf->{smp
};
2199 } elsif ($conf->{smp
}) {
2200 $conf->{sockets
} = $conf->{smp
};
2201 delete $conf->{cores
};
2202 delete $conf->{smp
};
2205 my $used_volids = {};
2207 my $cleanup_config = sub {
2208 my ($cref, $pending, $snapname) = @_;
2210 foreach my $key (keys %$cref) {
2211 next if $key eq 'digest' || $key eq 'description' || $key eq 'snapshots' ||
2212 $key eq 'snapstate' || $key eq 'pending';
2213 my $value = $cref->{$key};
2214 if ($key eq 'delete') {
2215 die "propertry 'delete' is only allowed in [PENDING]\n"
2217 # fixme: check syntax?
2220 eval { $value = check_type
($key, $value); };
2221 die "unable to parse value of '$key' - $@" if $@;
2223 $cref->{$key} = $value;
2225 if (!$snapname && is_valid_drivename
($key)) {
2226 my $drive = parse_drive
($key, $value);
2227 $used_volids->{$drive->{file
}} = 1 if $drive && $drive->{file
};
2232 &$cleanup_config($conf);
2234 &$cleanup_config($conf->{pending
}, 1);
2236 foreach my $snapname (keys %{$conf->{snapshots
}}) {
2237 die "internal error: snapshot name '$snapname' is forbidden" if lc($snapname) eq 'pending';
2238 &$cleanup_config($conf->{snapshots
}->{$snapname}, undef, $snapname);
2241 # remove 'unusedX' settings if we re-add a volume
2242 foreach my $key (keys %$conf) {
2243 my $value = $conf->{$key};
2244 if ($key =~ m/^unused/ && $used_volids->{$value}) {
2245 delete $conf->{$key};
2249 my $generate_raw_config = sub {
2250 my ($conf, $pending) = @_;
2254 # add description as comment to top of file
2255 if (defined(my $descr = $conf->{description
})) {
2257 foreach my $cl (split(/\n/, $descr)) {
2258 $raw .= '#' . PVE
::Tools
::encode_text
($cl) . "\n";
2261 $raw .= "#\n" if $pending;
2265 foreach my $key (sort keys %$conf) {
2266 next if $key eq 'digest' || $key eq 'description' || $key eq 'pending' || $key eq 'snapshots';
2267 $raw .= "$key: $conf->{$key}\n";
2272 my $raw = &$generate_raw_config($conf);
2274 if (scalar(keys %{$conf->{pending
}})){
2275 $raw .= "\n[PENDING]\n";
2276 $raw .= &$generate_raw_config($conf->{pending
}, 1);
2279 foreach my $snapname (sort keys %{$conf->{snapshots
}}) {
2280 $raw .= "\n[$snapname]\n";
2281 $raw .= &$generate_raw_config($conf->{snapshots
}->{$snapname});
2291 # we use static defaults from our JSON schema configuration
2292 foreach my $key (keys %$confdesc) {
2293 if (defined(my $default = $confdesc->{$key}->{default})) {
2294 $res->{$key} = $default;
2302 my $vmlist = PVE
::Cluster
::get_vmlist
();
2304 return $res if !$vmlist || !$vmlist->{ids
};
2305 my $ids = $vmlist->{ids
};
2306 my $nodename = nodename
();
2308 foreach my $vmid (keys %$ids) {
2309 my $d = $ids->{$vmid};
2310 next if !$d->{node
} || $d->{node
} ne $nodename;
2311 next if !$d->{type
} || $d->{type
} ne 'qemu';
2312 $res->{$vmid}->{exists} = 1;
2317 # test if VM uses local resources (to prevent migration)
2318 sub check_local_resources
{
2319 my ($conf, $noerr) = @_;
2323 push @loc_res, "hostusb" if $conf->{hostusb
}; # old syntax
2324 push @loc_res, "hostpci" if $conf->{hostpci
}; # old syntax
2326 push @loc_res, "ivshmem" if $conf->{ivshmem
};
2328 foreach my $k (keys %$conf) {
2329 next if $k =~ m/^usb/ && ($conf->{$k} =~ m/^spice(?![^,])/);
2330 # sockets are safe: they will recreated be on the target side post-migrate
2331 next if $k =~ m/^serial/ && ($conf->{$k} eq 'socket');
2332 push @loc_res, $k if $k =~ m/^(usb|hostpci|serial|parallel)\d+$/;
2335 die "VM uses local resources\n" if scalar @loc_res && !$noerr;
2340 # check if used storages are available on all nodes (use by migrate)
2341 sub check_storage_availability
{
2342 my ($storecfg, $conf, $node) = @_;
2344 foreach_drive
($conf, sub {
2345 my ($ds, $drive) = @_;
2347 my $volid = $drive->{file
};
2350 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2353 # check if storage is available on both nodes
2354 my $scfg = PVE
::Storage
::storage_check_node
($storecfg, $sid);
2355 PVE
::Storage
::storage_check_node
($storecfg, $sid, $node);
2359 # list nodes where all VM images are available (used by has_feature API)
2361 my ($conf, $storecfg) = @_;
2363 my $nodelist = PVE
::Cluster
::get_nodelist
();
2364 my $nodehash = { map { $_ => 1 } @$nodelist };
2365 my $nodename = nodename
();
2367 foreach_drive
($conf, sub {
2368 my ($ds, $drive) = @_;
2370 my $volid = $drive->{file
};
2373 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2375 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
2376 if ($scfg->{disable
}) {
2378 } elsif (my $avail = $scfg->{nodes
}) {
2379 foreach my $node (keys %$nodehash) {
2380 delete $nodehash->{$node} if !$avail->{$node};
2382 } elsif (!$scfg->{shared
}) {
2383 foreach my $node (keys %$nodehash) {
2384 delete $nodehash->{$node} if $node ne $nodename
2393 sub check_local_storage_availability
{
2394 my ($conf, $storecfg) = @_;
2396 my $nodelist = PVE
::Cluster
::get_nodelist
();
2397 my $nodehash = { map { $_ => {} } @$nodelist };
2399 foreach_drive
($conf, sub {
2400 my ($ds, $drive) = @_;
2402 my $volid = $drive->{file
};
2405 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2407 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
2409 if ($scfg->{disable
}) {
2410 foreach my $node (keys %$nodehash) {
2411 $nodehash->{$node}->{unavailable_storages
}->{$storeid} = 1;
2413 } elsif (my $avail = $scfg->{nodes
}) {
2414 foreach my $node (keys %$nodehash) {
2415 if (!$avail->{$node}) {
2416 $nodehash->{$node}->{unavailable_storages
}->{$storeid} = 1;
2423 foreach my $node (values %$nodehash) {
2424 if (my $unavail = $node->{unavailable_storages
}) {
2425 $node->{unavailable_storages
} = [ sort keys %$unavail ];
2432 # Compat only, use assert_config_exists_on_node and vm_running_locally where possible
2434 my ($vmid, $nocheck, $node) = @_;
2436 PVE
::QemuConfig
::assert_config_exists_on_node
($vmid, $node) if !$nocheck;
2437 return PVE
::QemuServer
::Helpers
::vm_running_locally
($vmid);
2442 my $vzlist = config_list
();
2444 my $fd = IO
::Dir-
>new($PVE::QemuServer
::Helpers
::var_run_tmpdir
) || return $vzlist;
2446 while (defined(my $de = $fd->read)) {
2447 next if $de !~ m/^(\d+)\.pid$/;
2449 next if !defined($vzlist->{$vmid});
2450 if (my $pid = check_running
($vmid)) {
2451 $vzlist->{$vmid}->{pid
} = $pid;
2458 our $vmstatus_return_properties = {
2459 vmid
=> get_standard_option
('pve-vmid'),
2461 description
=> "Qemu process status.",
2463 enum
=> ['stopped', 'running'],
2466 description
=> "Maximum memory in bytes.",
2469 renderer
=> 'bytes',
2472 description
=> "Root disk size in bytes.",
2475 renderer
=> 'bytes',
2478 description
=> "VM name.",
2483 description
=> "Qemu QMP agent status.",
2488 description
=> "PID of running qemu process.",
2493 description
=> "Uptime.",
2496 renderer
=> 'duration',
2499 description
=> "Maximum usable CPUs.",
2504 description
=> "The current config lock, if any.",
2509 description
=> "The current configured tags, if any",
2515 my $last_proc_pid_stat;
2517 # get VM status information
2518 # This must be fast and should not block ($full == false)
2519 # We only query KVM using QMP if $full == true (this can be slow)
2521 my ($opt_vmid, $full) = @_;
2525 my $storecfg = PVE
::Storage
::config
();
2527 my $list = vzlist
();
2528 my $defaults = load_defaults
();
2530 my ($uptime) = PVE
::ProcFSTools
::read_proc_uptime
(1);
2532 my $cpucount = $cpuinfo->{cpus
} || 1;
2534 foreach my $vmid (keys %$list) {
2535 next if $opt_vmid && ($vmid ne $opt_vmid);
2537 my $conf = PVE
::QemuConfig-
>load_config($vmid);
2539 my $d = { vmid
=> $vmid };
2540 $d->{pid
} = $list->{$vmid}->{pid
};
2542 # fixme: better status?
2543 $d->{status
} = $list->{$vmid}->{pid
} ?
'running' : 'stopped';
2545 my $size = PVE
::QemuServer
::Drive
::bootdisk_size
($storecfg, $conf);
2546 if (defined($size)) {
2547 $d->{disk
} = 0; # no info available
2548 $d->{maxdisk
} = $size;
2554 $d->{cpus
} = ($conf->{sockets
} || $defaults->{sockets
})
2555 * ($conf->{cores
} || $defaults->{cores
});
2556 $d->{cpus
} = $cpucount if $d->{cpus
} > $cpucount;
2557 $d->{cpus
} = $conf->{vcpus
} if $conf->{vcpus
};
2559 $d->{name
} = $conf->{name
} || "VM $vmid";
2560 $d->{maxmem
} = $conf->{memory
} ?
$conf->{memory
}*(1024*1024)
2561 : $defaults->{memory
}*(1024*1024);
2563 if ($conf->{balloon
}) {
2564 $d->{balloon_min
} = $conf->{balloon
}*(1024*1024);
2565 $d->{shares
} = defined($conf->{shares
}) ?
$conf->{shares
}
2566 : $defaults->{shares
};
2577 $d->{diskwrite
} = 0;
2579 $d->{template
} = PVE
::QemuConfig-
>is_template($conf);
2581 $d->{serial
} = 1 if conf_has_serial
($conf);
2582 $d->{lock} = $conf->{lock} if $conf->{lock};
2583 $d->{tags
} = $conf->{tags
} if defined($conf->{tags
});
2588 my $netdev = PVE
::ProcFSTools
::read_proc_net_dev
();
2589 foreach my $dev (keys %$netdev) {
2590 next if $dev !~ m/^tap([1-9]\d*)i/;
2592 my $d = $res->{$vmid};
2595 $d->{netout
} += $netdev->{$dev}->{receive
};
2596 $d->{netin
} += $netdev->{$dev}->{transmit
};
2599 $d->{nics
}->{$dev}->{netout
} = $netdev->{$dev}->{receive
};
2600 $d->{nics
}->{$dev}->{netin
} = $netdev->{$dev}->{transmit
};
2605 my $ctime = gettimeofday
;
2607 foreach my $vmid (keys %$list) {
2609 my $d = $res->{$vmid};
2610 my $pid = $d->{pid
};
2613 my $pstat = PVE
::ProcFSTools
::read_proc_pid_stat
($pid);
2614 next if !$pstat; # not running
2616 my $used = $pstat->{utime} + $pstat->{stime
};
2618 $d->{uptime
} = int(($uptime - $pstat->{starttime
})/$cpuinfo->{user_hz
});
2620 if ($pstat->{vsize
}) {
2621 $d->{mem
} = int(($pstat->{rss
}/$pstat->{vsize
})*$d->{maxmem
});
2624 my $old = $last_proc_pid_stat->{$pid};
2626 $last_proc_pid_stat->{$pid} = {
2634 my $dtime = ($ctime - $old->{time}) * $cpucount * $cpuinfo->{user_hz
};
2636 if ($dtime > 1000) {
2637 my $dutime = $used - $old->{used
};
2639 $d->{cpu
} = (($dutime/$dtime)* $cpucount) / $d->{cpus
};
2640 $last_proc_pid_stat->{$pid} = {
2646 $d->{cpu
} = $old->{cpu
};
2650 return $res if !$full;
2652 my $qmpclient = PVE
::QMPClient-
>new();
2654 my $ballooncb = sub {
2655 my ($vmid, $resp) = @_;
2657 my $info = $resp->{'return'};
2658 return if !$info->{max_mem
};
2660 my $d = $res->{$vmid};
2662 # use memory assigned to VM
2663 $d->{maxmem
} = $info->{max_mem
};
2664 $d->{balloon
} = $info->{actual
};
2666 if (defined($info->{total_mem
}) && defined($info->{free_mem
})) {
2667 $d->{mem
} = $info->{total_mem
} - $info->{free_mem
};
2668 $d->{freemem
} = $info->{free_mem
};
2671 $d->{ballooninfo
} = $info;
2674 my $blockstatscb = sub {
2675 my ($vmid, $resp) = @_;
2676 my $data = $resp->{'return'} || [];
2677 my $totalrdbytes = 0;
2678 my $totalwrbytes = 0;
2680 for my $blockstat (@$data) {
2681 $totalrdbytes = $totalrdbytes + $blockstat->{stats
}->{rd_bytes
};
2682 $totalwrbytes = $totalwrbytes + $blockstat->{stats
}->{wr_bytes
};
2684 $blockstat->{device
} =~ s/drive-//;
2685 $res->{$vmid}->{blockstat
}->{$blockstat->{device
}} = $blockstat->{stats
};
2687 $res->{$vmid}->{diskread
} = $totalrdbytes;
2688 $res->{$vmid}->{diskwrite
} = $totalwrbytes;
2691 my $statuscb = sub {
2692 my ($vmid, $resp) = @_;
2694 $qmpclient->queue_cmd($vmid, $blockstatscb, 'query-blockstats');
2695 # this fails if ballon driver is not loaded, so this must be
2696 # the last commnand (following command are aborted if this fails).
2697 $qmpclient->queue_cmd($vmid, $ballooncb, 'query-balloon');
2699 my $status = 'unknown';
2700 if (!defined($status = $resp->{'return'}->{status
})) {
2701 warn "unable to get VM status\n";
2705 $res->{$vmid}->{qmpstatus
} = $resp->{'return'}->{status
};
2708 foreach my $vmid (keys %$list) {
2709 next if $opt_vmid && ($vmid ne $opt_vmid);
2710 next if !$res->{$vmid}->{pid
}; # not running
2711 $qmpclient->queue_cmd($vmid, $statuscb, 'query-status');
2714 $qmpclient->queue_execute(undef, 2);
2716 foreach my $vmid (keys %$list) {
2717 next if $opt_vmid && ($vmid ne $opt_vmid);
2718 $res->{$vmid}->{qmpstatus
} = $res->{$vmid}->{status
} if !$res->{$vmid}->{qmpstatus
};
2724 sub conf_has_serial
{
2727 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
2728 if ($conf->{"serial$i"}) {
2736 sub conf_has_audio
{
2737 my ($conf, $id) = @_;
2740 my $audio = $conf->{"audio$id"};
2741 return undef if !defined($audio);
2743 my $audioproperties = PVE
::JSONSchema
::parse_property_string
($audio_fmt, $audio);
2744 my $audiodriver = $audioproperties->{driver
} // 'spice';
2747 dev
=> $audioproperties->{device
},
2748 dev_id
=> "audiodev$id",
2749 backend
=> $audiodriver,
2750 backend_id
=> "$audiodriver-backend${id}",
2754 sub vga_conf_has_spice
{
2757 my $vgaconf = parse_vga
($vga);
2758 my $vgatype = $vgaconf->{type
};
2759 return 0 if !$vgatype || $vgatype !~ m/^qxl([234])?$/;
2766 return get_host_arch
() eq $arch;
2771 return $conf->{arch
} // get_host_arch
();
2774 my $default_machines = {
2779 sub get_vm_machine
{
2780 my ($conf, $forcemachine, $arch, $add_pve_version, $kvmversion) = @_;
2782 my $machine = $forcemachine || $conf->{machine
};
2784 if (!$machine || $machine =~ m/^(?:pc|q35|virt)$/) {
2786 $machine ||= $default_machines->{$arch};
2787 if ($add_pve_version) {
2788 $kvmversion //= kvm_user_version
();
2789 my $pvever = PVE
::QemuServer
::Machine
::get_pve_version
($kvmversion);
2790 $machine .= "+pve$pvever";
2794 if ($add_pve_version && $machine !~ m/\+pve\d+$/) {
2795 # for version-pinned machines that do not include a pve-version (e.g.
2796 # pc-q35-4.1), we assume 0 to keep them stable in case we bump
2797 $machine .= '+pve0';
2803 sub get_ovmf_files
($) {
2806 my $ovmf = $OVMF->{$arch}
2807 or die "no OVMF images known for architecture '$arch'\n";
2813 aarch64
=> '/usr/bin/qemu-system-aarch64',
2814 x86_64
=> '/usr/bin/qemu-system-x86_64',
2816 sub get_command_for_arch
($) {
2818 return '/usr/bin/kvm' if is_native
($arch);
2820 my $cmd = $Arch2Qemu->{$arch}
2821 or die "don't know how to emulate architecture '$arch'\n";
2825 # To use query_supported_cpu_flags and query_understood_cpu_flags to get flags
2826 # to use in a QEMU command line (-cpu element), first array_intersect the result
2827 # of query_supported_ with query_understood_. This is necessary because:
2829 # a) query_understood_ returns flags the host cannot use and
2830 # b) query_supported_ (rather the QMP call) doesn't actually return CPU
2831 # flags, but CPU settings - with most of them being flags. Those settings
2832 # (and some flags, curiously) cannot be specified as a "-cpu" argument.
2834 # query_supported_ needs to start up to 2 temporary VMs and is therefore rather
2835 # expensive. If you need the value returned from this, you can get it much
2836 # cheaper from pmxcfs using PVE::Cluster::get_node_kv('cpuflags-$accel') with
2837 # $accel being 'kvm' or 'tcg'.
2839 # pvestatd calls this function on startup and whenever the QEMU/KVM version
2840 # changes, automatically populating pmxcfs.
2842 # Returns: { kvm => [ flagX, flagY, ... ], tcg => [ flag1, flag2, ... ] }
2843 # since kvm and tcg machines support different flags
2845 sub query_supported_cpu_flags
{
2848 $arch //= get_host_arch
();
2849 my $default_machine = $default_machines->{$arch};
2853 # FIXME: Once this is merged, the code below should work for ARM as well:
2854 # https://lists.nongnu.org/archive/html/qemu-devel/2019-06/msg04947.html
2855 die "QEMU/KVM cannot detect CPU flags on ARM (aarch64)\n" if
2858 my $kvm_supported = defined(kvm_version
());
2859 my $qemu_cmd = get_command_for_arch
($arch);
2861 my $pidfile = PVE
::QemuServer
::Helpers
::pidfile_name
($fakevmid);
2863 # Start a temporary (frozen) VM with vmid -1 to allow sending a QMP command
2864 my $query_supported_run_qemu = sub {
2870 '-machine', $default_machine,
2872 '-chardev', "socket,id=qmp,path=/var/run/qemu-server/$fakevmid.qmp,server,nowait",
2873 '-mon', 'chardev=qmp,mode=control',
2874 '-pidfile', $pidfile,
2879 push @$cmd, '-accel', 'tcg';
2882 my $rc = run_command
($cmd, noerr
=> 1, quiet
=> 0);
2883 die "QEMU flag querying VM exited with code " . $rc if $rc;
2886 my $cmd_result = mon_cmd
(
2888 'query-cpu-model-expansion',
2890 model
=> { name
=> 'host' }
2893 my $props = $cmd_result->{model
}->{props
};
2894 foreach my $prop (keys %$props) {
2895 next if $props->{$prop} ne '1';
2896 # QEMU returns some flags multiple times, with '_', '.' or '-'
2897 # (e.g. lahf_lm and lahf-lm; sse4.2, sse4-2 and sse4_2; ...).
2898 # We only keep those with underscores, to match /proc/cpuinfo
2899 $prop =~ s/\.|-/_/g;
2900 $flags->{$prop} = 1;
2905 # force stop with 10 sec timeout and 'nocheck'
2906 # always stop, even if QMP failed
2907 vm_stop
(undef, $fakevmid, 1, 1, 10, 0, 1);
2911 return [ sort keys %$flags ];
2914 # We need to query QEMU twice, since KVM and TCG have different supported flags
2915 PVE
::QemuConfig-
>lock_config($fakevmid, sub {
2916 $flags->{tcg
} = eval { $query_supported_run_qemu->(0) };
2917 warn "warning: failed querying supported tcg flags: $@\n" if $@;
2919 if ($kvm_supported) {
2920 $flags->{kvm
} = eval { $query_supported_run_qemu->(1) };
2921 warn "warning: failed querying supported kvm flags: $@\n" if $@;
2928 # Understood CPU flags are written to a file at 'pve-qemu' compile time
2929 my $understood_cpu_flag_dir = "/usr/share/kvm";
2930 sub query_understood_cpu_flags
{
2931 my $arch = get_host_arch
();
2932 my $filepath = "$understood_cpu_flag_dir/recognized-CPUID-flags-$arch";
2934 die "Cannot query understood QEMU CPU flags for architecture: $arch (file not found)\n"
2937 my $raw = file_get_contents
($filepath);
2938 $raw =~ s/^\s+|\s+$//g;
2939 my @flags = split(/\s+/, $raw);
2944 sub config_to_command
{
2945 my ($storecfg, $vmid, $conf, $defaults, $forcemachine, $forcecpu) = @_;
2948 my $globalFlags = [];
2949 my $machineFlags = [];
2954 my $ostype = $conf->{ostype
};
2955 my $winversion = windows_version
($ostype);
2956 my $kvm = $conf->{kvm
};
2957 my $nodename = nodename
();
2959 my $arch = get_vm_arch
($conf);
2960 my $kvm_binary = get_command_for_arch
($arch);
2961 my $kvmver = kvm_user_version
($kvm_binary);
2963 if (!$kvmver || $kvmver !~ m/^(\d+)\.(\d+)/ || $1 < 3) {
2964 $kvmver //= "undefined";
2965 die "Detected old QEMU binary ('$kvmver', at least 3.0 is required)\n";
2968 my $add_pve_version = min_version
($kvmver, 4, 1);
2970 my $machine_type = get_vm_machine
($conf, $forcemachine, $arch, $add_pve_version);
2971 my $machine_version = PVE
::QemuServer
::Machine
::extract_version
($machine_type, $kvmver);
2972 $kvm //= 1 if is_native
($arch);
2974 $machine_version =~ m/(\d+)\.(\d+)/;
2975 my ($machine_major, $machine_minor) = ($1, $2);
2977 if ($kvmver =~ m/^\d+\.\d+\.(\d+)/ && $1 >= 90) {
2978 warn "warning: Installed QEMU version ($kvmver) is a release candidate, ignoring version checks\n";
2979 } elsif (!min_version
($kvmver, $machine_major, $machine_minor)) {
2980 die "Installed QEMU version '$kvmver' is too old to run machine type '$machine_type', please upgrade node '$nodename'\n"
2981 } elsif (!PVE
::QemuServer
::Machine
::can_run_pve_machine_version
($machine_version, $kvmver)) {
2982 my $max_pve_version = PVE
::QemuServer
::Machine
::get_pve_version
($machine_version);
2983 die "Installed qemu-server (max feature level for $machine_major.$machine_minor is pve$max_pve_version)"
2984 ." is too old to run machine type '$machine_type', please upgrade node '$nodename'\n";
2987 # if a specific +pve version is required for a feature, use $version_guard
2988 # instead of min_version to allow machines to be run with the minimum
2990 my $required_pve_version = 0;
2991 my $version_guard = sub {
2992 my ($major, $minor, $pve) = @_;
2993 return 0 if !min_version
($machine_version, $major, $minor, $pve);
2994 my $max_pve = PVE
::QemuServer
::Machine
::get_pve_version
("$major.$minor");
2995 return 1 if min_version
($machine_version, $major, $minor, $max_pve+1);
2996 $required_pve_version = $pve if $pve && $pve > $required_pve_version;
3001 die "KVM virtualisation configured, but not available. Either disable in VM configuration or enable in BIOS.\n"
3002 if !defined kvm_version
();
3005 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
3006 my $hotplug_features = parse_hotplug_features
(defined($conf->{hotplug
}) ?
$conf->{hotplug
} : '1');
3007 my $use_old_bios_files = undef;
3008 ($use_old_bios_files, $machine_type) = qemu_use_old_bios_files
($machine_type);
3010 my $cpuunits = defined($conf->{cpuunits
}) ?
3011 $conf->{cpuunits
} : $defaults->{cpuunits
};
3013 push @$cmd, $kvm_binary;
3015 push @$cmd, '-id', $vmid;
3017 my $vmname = $conf->{name
} || "vm$vmid";
3019 push @$cmd, '-name', $vmname;
3023 my $qmpsocket = PVE
::QemuServer
::Helpers
::qmp_socket
($vmid);
3024 push @$cmd, '-chardev', "socket,id=qmp,path=$qmpsocket,server,nowait";
3025 push @$cmd, '-mon', "chardev=qmp,mode=control";
3027 if (min_version
($machine_version, 2, 12)) {
3028 push @$cmd, '-chardev', "socket,id=qmp-event,path=/var/run/qmeventd.sock,reconnect=5";
3029 push @$cmd, '-mon', "chardev=qmp-event,mode=control";
3032 push @$cmd, '-pidfile' , PVE
::QemuServer
::Helpers
::pidfile_name
($vmid);
3034 push @$cmd, '-daemonize';
3036 if ($conf->{smbios1
}) {
3037 my $smbios_conf = parse_smbios1
($conf->{smbios1
});
3038 if ($smbios_conf->{base64
}) {
3039 # Do not pass base64 flag to qemu
3040 delete $smbios_conf->{base64
};
3041 my $smbios_string = "";
3042 foreach my $key (keys %$smbios_conf) {
3044 if ($key eq "uuid") {
3045 $value = $smbios_conf->{uuid
}
3047 $value = decode_base64
($smbios_conf->{$key});
3049 # qemu accepts any binary data, only commas need escaping by double comma
3051 $smbios_string .= "," . $key . "=" . $value if $value;
3053 push @$cmd, '-smbios', "type=1" . $smbios_string;
3055 push @$cmd, '-smbios', "type=1,$conf->{smbios1}";
3059 my ($ovmf_code, $ovmf_vars) = get_ovmf_files
($arch);
3060 if ($conf->{bios
} && $conf->{bios
} eq 'ovmf') {
3061 die "uefi base image not found\n" if ! -f
$ovmf_code;
3065 if (my $efidisk = $conf->{efidisk0
}) {
3066 my $d = parse_drive
('efidisk0', $efidisk);
3067 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($d->{file
}, 1);
3068 $format = $d->{format
};
3070 $path = PVE
::Storage
::path
($storecfg, $d->{file
});
3071 if (!defined($format)) {
3072 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
3073 $format = qemu_img_format
($scfg, $volname);
3077 die "efidisk format must be specified\n"
3078 if !defined($format);
3081 warn "no efidisk configured! Using temporary efivars disk.\n";
3082 $path = "/tmp/$vmid-ovmf.fd";
3083 PVE
::Tools
::file_copy
($ovmf_vars, $path, -s
$ovmf_vars);
3089 if ($format eq 'raw' && $version_guard->(4, 1, 2)) {
3090 $size_str = ",size=" . (-s
$ovmf_vars);
3093 push @$cmd, '-drive', "if=pflash,unit=0,format=raw,readonly,file=$ovmf_code";
3094 push @$cmd, '-drive', "if=pflash,unit=1,format=$format,id=drive-efidisk0$size_str,file=$path";
3099 # we use different pcie-port hardware for qemu >= 4.0 for passthrough
3100 if (min_version
($machine_version, 4, 0)) {
3101 push @$devices, '-readconfig', '/usr/share/qemu-server/pve-q35-4.0.cfg';
3103 push @$devices, '-readconfig', '/usr/share/qemu-server/pve-q35.cfg';
3107 if ($conf->{vmgenid
}) {
3108 push @$devices, '-device', 'vmgenid,guid='.$conf->{vmgenid
};
3111 # add usb controllers
3112 my @usbcontrollers = PVE
::QemuServer
::USB
::get_usb_controllers
($conf, $bridges, $arch, $machine_type, $usbdesc->{format
}, $MAX_USB_DEVICES);
3113 push @$devices, @usbcontrollers if @usbcontrollers;
3114 my $vga = parse_vga
($conf->{vga
});
3116 my $qxlnum = vga_conf_has_spice
($conf->{vga
});
3117 $vga->{type
} = 'qxl' if $qxlnum;
3119 if (!$vga->{type
}) {
3120 if ($arch eq 'aarch64') {
3121 $vga->{type
} = 'virtio';
3122 } elsif (min_version
($machine_version, 2, 9)) {
3123 $vga->{type
} = (!$winversion || $winversion >= 6) ?
'std' : 'cirrus';
3125 $vga->{type
} = ($winversion >= 6) ?
'std' : 'cirrus';
3129 # enable absolute mouse coordinates (needed by vnc)
3131 if (defined($conf->{tablet
})) {
3132 $tablet = $conf->{tablet
};
3134 $tablet = $defaults->{tablet
};
3135 $tablet = 0 if $qxlnum; # disable for spice because it is not needed
3136 $tablet = 0 if $vga->{type
} =~ m/^serial\d+$/; # disable if we use serial terminal (no vga card)
3140 push @$devices, '-device', print_tabletdevice_full
($conf, $arch) if $tablet;
3141 my $kbd = print_keyboarddevice_full
($conf, $arch);
3142 push @$devices, '-device', $kbd if defined($kbd);
3146 my $gpu_passthrough;
3149 for (my $i = 0; $i < $MAX_HOSTPCI_DEVICES; $i++) {
3150 my $id = "hostpci$i";
3151 my $d = parse_hostpci
($conf->{$id});
3154 if (my $pcie = $d->{pcie
}) {
3155 die "q35 machine model is not enabled" if !$q35;
3156 # win7 wants to have the pcie devices directly on the pcie bus
3157 # instead of in the root port
3158 if ($winversion == 7) {
3159 $pciaddr = print_pcie_addr
("${id}bus0");
3161 # add more root ports if needed, 4 are present by default
3162 # by pve-q35 cfgs, rest added here on demand.
3164 push @$devices, '-device', print_pcie_root_port
($i);
3166 $pciaddr = print_pcie_addr
($id);
3169 $pciaddr = print_pci_addr
($id, $bridges, $arch, $machine_type);
3173 if ($d->{'x-vga'}) {
3174 $xvga = ',x-vga=on' if !($conf->{bios
} && $conf->{bios
} eq 'ovmf');
3176 $vga->{type
} = 'none' if !defined($conf->{vga
});
3177 $gpu_passthrough = 1;
3180 my $pcidevices = $d->{pciid
};
3181 my $multifunction = 1 if @$pcidevices > 1;
3184 if ($d->{mdev
} && scalar(@$pcidevices) == 1) {
3185 my $pci_id = $pcidevices->[0]->{id
};
3186 my $uuid = PVE
::SysFSTools
::generate_mdev_uuid
($vmid, $i);
3187 $sysfspath = "/sys/bus/pci/devices/$pci_id/$uuid";
3188 } elsif ($d->{mdev
}) {
3189 warn "ignoring mediated device '$id' with multifunction device\n";
3193 foreach my $pcidevice (@$pcidevices) {
3194 my $devicestr = "vfio-pci";
3197 $devicestr .= ",sysfsdev=$sysfspath";
3199 $devicestr .= ",host=$pcidevice->{id}";
3202 my $mf_addr = $multifunction ?
".$j" : '';
3203 $devicestr .= ",id=${id}${mf_addr}${pciaddr}${mf_addr}";
3206 $devicestr .= ',rombar=0' if defined($d->{rombar
}) && !$d->{rombar
};
3207 $devicestr .= "$xvga";
3208 $devicestr .= ",multifunction=on" if $multifunction;
3209 $devicestr .= ",romfile=/usr/share/kvm/$d->{romfile}" if $d->{romfile
};
3212 push @$devices, '-device', $devicestr;
3218 my $usb_dev_features = {};
3219 $usb_dev_features->{spice_usb3
} = 1 if min_version
($machine_version, 4, 0);
3221 my @usbdevices = PVE
::QemuServer
::USB
::get_usb_devices
($conf, $usbdesc->{format
}, $MAX_USB_DEVICES, $usb_dev_features);
3222 push @$devices, @usbdevices if @usbdevices;
3224 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
3225 if (my $path = $conf->{"serial$i"}) {
3226 if ($path eq 'socket') {
3227 my $socket = "/var/run/qemu-server/${vmid}.serial$i";
3228 push @$devices, '-chardev', "socket,id=serial$i,path=$socket,server,nowait";
3229 # On aarch64, serial0 is the UART device. Qemu only allows
3230 # connecting UART devices via the '-serial' command line, as
3231 # the device has a fixed slot on the hardware...
3232 if ($arch eq 'aarch64' && $i == 0) {
3233 push @$devices, '-serial', "chardev:serial$i";
3235 push @$devices, '-device', "isa-serial,chardev=serial$i";
3238 die "no such serial device\n" if ! -c
$path;
3239 push @$devices, '-chardev', "tty,id=serial$i,path=$path";
3240 push @$devices, '-device', "isa-serial,chardev=serial$i";
3246 for (my $i = 0; $i < $MAX_PARALLEL_PORTS; $i++) {
3247 if (my $path = $conf->{"parallel$i"}) {
3248 die "no such parallel device\n" if ! -c
$path;
3249 my $devtype = $path =~ m!^/dev/usb/lp! ?
'tty' : 'parport';
3250 push @$devices, '-chardev', "$devtype,id=parallel$i,path=$path";
3251 push @$devices, '-device', "isa-parallel,chardev=parallel$i";
3255 if (my $audio = conf_has_audio
($conf)) {
3257 my $audiopciaddr = print_pci_addr
("audio0", $bridges, $arch, $machine_type);
3259 my $id = $audio->{dev_id
};
3260 if ($audio->{dev
} eq 'AC97') {
3261 push @$devices, '-device', "AC97,id=${id}${audiopciaddr}";
3262 } elsif ($audio->{dev
} =~ /intel\-hda$/) {
3263 push @$devices, '-device', "$audio->{dev},id=${id}${audiopciaddr}";
3264 push @$devices, '-device', "hda-micro,id=${id}-codec0,bus=${id}.0,cad=0";
3265 push @$devices, '-device', "hda-duplex,id=${id}-codec1,bus=${id}.0,cad=1";
3267 die "unkown audio device '$audio->{dev}', implement me!";
3270 push @$devices, '-audiodev', "$audio->{backend},id=$audio->{backend_id}";
3274 $sockets = $conf->{smp
} if $conf->{smp
}; # old style - no longer iused
3275 $sockets = $conf->{sockets
} if $conf->{sockets
};
3277 my $cores = $conf->{cores
} || 1;
3279 my $maxcpus = $sockets * $cores;
3281 my $vcpus = $conf->{vcpus
} ?
$conf->{vcpus
} : $maxcpus;
3283 my $allowed_vcpus = $cpuinfo->{cpus
};
3285 die "MAX $allowed_vcpus vcpus allowed per VM on this node\n"
3286 if ($allowed_vcpus < $maxcpus);
3288 if($hotplug_features->{cpu
} && min_version
($machine_version, 2, 7)) {
3290 push @$cmd, '-smp', "1,sockets=$sockets,cores=$cores,maxcpus=$maxcpus";
3291 for (my $i = 2; $i <= $vcpus; $i++) {
3292 my $cpustr = print_cpu_device
($conf,$i);
3293 push @$cmd, '-device', $cpustr;
3298 push @$cmd, '-smp', "$vcpus,sockets=$sockets,cores=$cores,maxcpus=$maxcpus";
3300 push @$cmd, '-nodefaults';
3302 my $bootorder = $conf->{boot
} || $confdesc->{boot
}->{default};
3304 my $bootindex_hash = {};
3306 foreach my $o (split(//, $bootorder)) {
3307 $bootindex_hash->{$o} = $i*100;
3311 push @$cmd, '-boot', "menu=on,strict=on,reboot-timeout=1000,splash=/usr/share/qemu-server/bootsplash.jpg";
3313 push @$cmd, '-no-acpi' if defined($conf->{acpi
}) && $conf->{acpi
} == 0;
3315 push @$cmd, '-no-reboot' if defined($conf->{reboot
}) && $conf->{reboot
} == 0;
3317 if ($vga->{type
} && $vga->{type
} !~ m/^serial\d+$/ && $vga->{type
} ne 'none'){
3318 push @$devices, '-device', print_vga_device
($conf, $vga, $arch, $machine_version, $machine_type, undef, $qxlnum, $bridges);
3319 my $socket = PVE
::QemuServer
::Helpers
::vnc_socket
($vmid);
3320 push @$cmd, '-vnc', "unix:$socket,password";
3322 push @$cmd, '-vga', 'none' if $vga->{type
} eq 'none';
3323 push @$cmd, '-nographic';
3327 my $tdf = defined($conf->{tdf
}) ?
$conf->{tdf
} : $defaults->{tdf
};
3328 my $useLocaltime = $conf->{localtime};
3330 if ($winversion >= 5) { # windows
3331 $useLocaltime = 1 if !defined($conf->{localtime});
3333 # use time drift fix when acpi is enabled
3334 if (!(defined($conf->{acpi
}) && $conf->{acpi
} == 0)) {
3335 $tdf = 1 if !defined($conf->{tdf
});
3339 if ($winversion >= 6) {
3340 push @$globalFlags, 'kvm-pit.lost_tick_policy=discard';
3341 push @$cmd, '-no-hpet';
3344 push @$rtcFlags, 'driftfix=slew' if $tdf;
3346 if ($conf->{startdate
} && $conf->{startdate
} ne 'now') {
3347 push @$rtcFlags, "base=$conf->{startdate}";
3348 } elsif ($useLocaltime) {
3349 push @$rtcFlags, 'base=localtime';
3353 push @$cmd, '-cpu', $forcecpu;
3355 push @$cmd, get_cpu_options
($conf, $arch, $kvm, $kvm_off, $machine_version, $winversion, $gpu_passthrough);
3358 PVE
::QemuServer
::Memory
::config
($conf, $vmid, $sockets, $cores, $defaults, $hotplug_features, $cmd);
3360 push @$cmd, '-S' if $conf->{freeze
};
3362 push @$cmd, '-k', $conf->{keyboard
} if defined($conf->{keyboard
});
3364 my $guest_agent = parse_guest_agent
($conf);
3366 if ($guest_agent->{enabled
}) {
3367 my $qgasocket = PVE
::QemuServer
::Helpers
::qmp_socket
($vmid, 1);
3368 push @$devices, '-chardev', "socket,path=$qgasocket,server,nowait,id=qga0";
3370 if (!$guest_agent->{type
} || $guest_agent->{type
} eq 'virtio') {
3371 my $pciaddr = print_pci_addr
("qga0", $bridges, $arch, $machine_type);
3372 push @$devices, '-device', "virtio-serial,id=qga0$pciaddr";
3373 push @$devices, '-device', 'virtserialport,chardev=qga0,name=org.qemu.guest_agent.0';
3374 } elsif ($guest_agent->{type
} eq 'isa') {
3375 push @$devices, '-device', "isa-serial,chardev=qga0";
3379 my $rng = parse_rng
($conf->{rng0
}) if $conf->{rng0
};
3380 if ($rng && &$version_guard(4, 1, 2)) {
3381 my $max_bytes = $rng->{max_bytes
} // $rng_fmt->{max_bytes
}->{default};
3382 my $period = $rng->{period
} // $rng_fmt->{period
}->{default};
3384 my $limiter_str = "";
3386 $limiter_str = ",max-bytes=$max_bytes,period=$period";
3389 # mostly relevant for /dev/hwrng, but doesn't hurt to check others too
3390 die "cannot create VirtIO RNG device: source file '$rng->{source}' doesn't exist\n"
3391 if ! -e
$rng->{source
};
3393 my $rng_addr = print_pci_addr
("rng0", $bridges, $arch, $machine_type);
3395 push @$devices, '-object', "rng-random,filename=$rng->{source},id=rng0";
3396 push @$devices, '-device', "virtio-rng-pci,rng=rng0$limiter_str$rng_addr";
3404 for (my $i = 1; $i < $qxlnum; $i++){
3405 push @$devices, '-device', print_vga_device
($conf, $vga, $arch, $machine_version, $machine_type, $i, $qxlnum, $bridges);
3408 # assume other OS works like Linux
3409 my ($ram, $vram) = ("134217728", "67108864");
3410 if ($vga->{memory
}) {
3411 $ram = PVE
::Tools
::convert_size
($qxlnum*4*$vga->{memory
}, 'mb' => 'b');
3412 $vram = PVE
::Tools
::convert_size
($qxlnum*2*$vga->{memory
}, 'mb' => 'b');
3414 push @$cmd, '-global', "qxl-vga.ram_size=$ram";
3415 push @$cmd, '-global', "qxl-vga.vram_size=$vram";
3419 my $pciaddr = print_pci_addr
("spice", $bridges, $arch, $machine_type);
3421 my $pfamily = PVE
::Tools
::get_host_address_family
($nodename);
3422 my @nodeaddrs = PVE
::Tools
::getaddrinfo_all
('localhost', family
=> $pfamily);
3423 die "failed to get an ip address of type $pfamily for 'localhost'\n" if !@nodeaddrs;
3425 push @$devices, '-device', "virtio-serial,id=spice$pciaddr";
3426 push @$devices, '-chardev', "spicevmc,id=vdagent,name=vdagent";
3427 push @$devices, '-device', "virtserialport,chardev=vdagent,name=com.redhat.spice.0";
3429 my $localhost = PVE
::Network
::addr_to_ip
($nodeaddrs[0]->{addr
});
3430 $spice_port = PVE
::Tools
::next_spice_port
($pfamily, $localhost);
3432 my $spice_enhancement = PVE
::JSONSchema
::parse_property_string
($spice_enhancements_fmt, $conf->{spice_enhancements
} // '');
3433 if ($spice_enhancement->{foldersharing
}) {
3434 push @$devices, '-chardev', "spiceport,id=foldershare,name=org.spice-space.webdav.0";
3435 push @$devices, '-device', "virtserialport,chardev=foldershare,name=org.spice-space.webdav.0";
3438 my $spice_opts = "tls-port=${spice_port},addr=$localhost,tls-ciphers=HIGH,seamless-migration=on";
3439 $spice_opts .= ",streaming-video=$spice_enhancement->{videostreaming}" if $spice_enhancement->{videostreaming
};
3440 push @$devices, '-spice', "$spice_opts";
3443 # enable balloon by default, unless explicitly disabled
3444 if (!defined($conf->{balloon
}) || $conf->{balloon
}) {
3445 $pciaddr = print_pci_addr
("balloon0", $bridges, $arch, $machine_type);
3446 push @$devices, '-device', "virtio-balloon-pci,id=balloon0$pciaddr";
3449 if ($conf->{watchdog
}) {
3450 my $wdopts = parse_watchdog
($conf->{watchdog
});
3451 $pciaddr = print_pci_addr
("watchdog", $bridges, $arch, $machine_type);
3452 my $watchdog = $wdopts->{model
} || 'i6300esb';
3453 push @$devices, '-device', "$watchdog$pciaddr";
3454 push @$devices, '-watchdog-action', $wdopts->{action
} if $wdopts->{action
};
3458 my $scsicontroller = {};
3459 my $ahcicontroller = {};
3460 my $scsihw = defined($conf->{scsihw
}) ?
$conf->{scsihw
} : $defaults->{scsihw
};
3462 # Add iscsi initiator name if available
3463 if (my $initiator = get_initiator_name
()) {
3464 push @$devices, '-iscsi', "initiator-name=$initiator";
3467 foreach_drive
($conf, sub {
3468 my ($ds, $drive) = @_;
3470 if (PVE
::Storage
::parse_volume_id
($drive->{file
}, 1)) {
3471 push @$vollist, $drive->{file
};
3474 # ignore efidisk here, already added in bios/fw handling code above
3475 return if $drive->{interface
} eq 'efidisk';
3477 $use_virtio = 1 if $ds =~ m/^virtio/;
3479 if (drive_is_cdrom
($drive)) {
3480 if ($bootindex_hash->{d
}) {
3481 $drive->{bootindex
} = $bootindex_hash->{d
};
3482 $bootindex_hash->{d
} += 1;
3485 if ($bootindex_hash->{c
}) {
3486 $drive->{bootindex
} = $bootindex_hash->{c
} if $conf->{bootdisk
} && ($conf->{bootdisk
} eq $ds);
3487 $bootindex_hash->{c
} += 1;
3491 if ($drive->{interface
} eq 'virtio'){
3492 push @$cmd, '-object', "iothread,id=iothread-$ds" if $drive->{iothread
};
3495 if ($drive->{interface
} eq 'scsi') {
3497 my ($maxdev, $controller, $controller_prefix) = scsihw_infos
($conf, $drive);
3499 die "scsi$drive->{index}: machine version 4.1~pve2 or higher is required to use more than 14 SCSI disks\n"
3500 if $drive->{index} > 13 && !&$version_guard(4, 1, 2);
3502 $pciaddr = print_pci_addr
("$controller_prefix$controller", $bridges, $arch, $machine_type);
3503 my $scsihw_type = $scsihw =~ m/^virtio-scsi-single/ ?
"virtio-scsi-pci" : $scsihw;
3506 if($conf->{scsihw
} && $conf->{scsihw
} eq "virtio-scsi-single" && $drive->{iothread
}){
3507 $iothread .= ",iothread=iothread-$controller_prefix$controller";
3508 push @$cmd, '-object', "iothread,id=iothread-$controller_prefix$controller";
3509 } elsif ($drive->{iothread
}) {
3510 warn "iothread is only valid with virtio disk or virtio-scsi-single controller, ignoring\n";
3514 if($conf->{scsihw
} && $conf->{scsihw
} eq "virtio-scsi-single" && $drive->{queues
}){
3515 $queues = ",num_queues=$drive->{queues}";
3518 push @$devices, '-device', "$scsihw_type,id=$controller_prefix$controller$pciaddr$iothread$queues" if !$scsicontroller->{$controller};
3519 $scsicontroller->{$controller}=1;
3522 if ($drive->{interface
} eq 'sata') {
3523 my $controller = int($drive->{index} / $PVE::QemuServer
::Drive
::MAX_SATA_DISKS
);
3524 $pciaddr = print_pci_addr
("ahci$controller", $bridges, $arch, $machine_type);
3525 push @$devices, '-device', "ahci,id=ahci$controller,multifunction=on$pciaddr" if !$ahcicontroller->{$controller};
3526 $ahcicontroller->{$controller}=1;
3529 my $drive_cmd = print_drive_commandline_full
($storecfg, $vmid, $drive);
3530 push @$devices, '-drive',$drive_cmd;
3531 push @$devices, '-device', print_drivedevice_full
($storecfg, $conf, $vmid, $drive, $bridges, $arch, $machine_type);
3534 for (my $i = 0; $i < $MAX_NETS; $i++) {
3535 next if !$conf->{"net$i"};
3536 my $d = parse_net
($conf->{"net$i"});
3539 $use_virtio = 1 if $d->{model
} eq 'virtio';
3541 if ($bootindex_hash->{n
}) {
3542 $d->{bootindex
} = $bootindex_hash->{n
};
3543 $bootindex_hash->{n
} += 1;
3546 my $netdevfull = print_netdev_full
($vmid, $conf, $arch, $d, "net$i");
3547 push @$devices, '-netdev', $netdevfull;
3549 my $netdevicefull = print_netdevice_full
($vmid, $conf, $d, "net$i", $bridges, $use_old_bios_files, $arch, $machine_type);
3550 push @$devices, '-device', $netdevicefull;
3553 if ($conf->{ivshmem
}) {
3554 my $ivshmem = PVE
::JSONSchema
::parse_property_string
($ivshmem_fmt, $conf->{ivshmem
});
3558 $bus = print_pcie_addr
("ivshmem");
3560 $bus = print_pci_addr
("ivshmem", $bridges, $arch, $machine_type);
3563 my $ivshmem_name = $ivshmem->{name
} // $vmid;
3564 my $path = '/dev/shm/pve-shm-' . $ivshmem_name;
3566 push @$devices, '-device', "ivshmem-plain,memdev=ivshmem$bus,";
3567 push @$devices, '-object', "memory-backend-file,id=ivshmem,share=on,mem-path=$path,size=$ivshmem->{size}M";
3570 # pci.4 is nested in pci.1
3571 $bridges->{1} = 1 if $bridges->{4};
3575 if (min_version
($machine_version, 2, 3)) {
3580 $bridges->{3} = 1 if $scsihw =~ m/^virtio-scsi-single/;
3584 for my $k (sort {$b cmp $a} keys %$bridges) {
3585 next if $q35 && $k < 4; # q35.cfg already includes bridges up to 3
3586 $pciaddr = print_pci_addr
("pci.$k", undef, $arch, $machine_type);
3587 my $devstr = "pci-bridge,id=pci.$k,chassis_nr=$k$pciaddr";
3589 # add after -readconfig pve-q35.cfg
3590 splice @$devices, 2, 0, '-device', $devstr;
3592 unshift @$devices, '-device', $devstr if $k > 0;
3597 push @$machineFlags, 'accel=tcg';
3600 my $machine_type_min = $machine_type;
3601 if ($add_pve_version) {
3602 $machine_type_min =~ s/\+pve\d+$//;
3603 $machine_type_min .= "+pve$required_pve_version";
3605 push @$machineFlags, "type=${machine_type_min}";
3607 push @$cmd, @$devices;
3608 push @$cmd, '-rtc', join(',', @$rtcFlags) if scalar(@$rtcFlags);
3609 push @$cmd, '-machine', join(',', @$machineFlags) if scalar(@$machineFlags);
3610 push @$cmd, '-global', join(',', @$globalFlags) if scalar(@$globalFlags);
3612 if (my $vmstate = $conf->{vmstate
}) {
3613 my $statepath = PVE
::Storage
::path
($storecfg, $vmstate);
3614 push @$vollist, $vmstate;
3615 push @$cmd, '-loadstate', $statepath;
3616 print "activating and using '$vmstate' as vmstate\n";
3620 if ($conf->{args
}) {
3621 my $aa = PVE
::Tools
::split_args
($conf->{args
});
3625 return wantarray ?
($cmd, $vollist, $spice_port) : $cmd;
3631 my $res = mon_cmd
($vmid, 'query-spice');
3633 return $res->{'tls-port'} || $res->{'port'} || die "no spice port\n";
3636 sub vm_devices_list
{
3639 my $res = mon_cmd
($vmid, 'query-pci');
3640 my $devices_to_check = [];
3642 foreach my $pcibus (@$res) {
3643 push @$devices_to_check, @{$pcibus->{devices
}},
3646 while (@$devices_to_check) {
3648 for my $d (@$devices_to_check) {
3649 $devices->{$d->{'qdev_id'}} = 1 if $d->{'qdev_id'};
3650 next if !$d->{'pci_bridge'};
3652 $devices->{$d->{'qdev_id'}} += scalar(@{$d->{'pci_bridge'}->{devices
}});
3653 push @$to_check, @{$d->{'pci_bridge'}->{devices
}};
3655 $devices_to_check = $to_check;
3658 my $resblock = mon_cmd
($vmid, 'query-block');
3659 foreach my $block (@$resblock) {
3660 if($block->{device
} =~ m/^drive-(\S+)/){
3665 my $resmice = mon_cmd
($vmid, 'query-mice');
3666 foreach my $mice (@$resmice) {
3667 if ($mice->{name
} eq 'QEMU HID Tablet') {
3668 $devices->{tablet
} = 1;
3673 # for usb devices there is no query-usb
3674 # but we can iterate over the entries in
3675 # qom-list path=/machine/peripheral
3676 my $resperipheral = mon_cmd
($vmid, 'qom-list', path
=> '/machine/peripheral');
3677 foreach my $per (@$resperipheral) {
3678 if ($per->{name
} =~ m/^usb\d+$/) {
3679 $devices->{$per->{name
}} = 1;
3687 my ($storecfg, $conf, $vmid, $deviceid, $device, $arch, $machine_type) = @_;
3689 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
3691 my $devices_list = vm_devices_list
($vmid);
3692 return 1 if defined($devices_list->{$deviceid});
3694 qemu_add_pci_bridge
($storecfg, $conf, $vmid, $deviceid, $arch, $machine_type); # add PCI bridge if we need it for the device
3696 if ($deviceid eq 'tablet') {
3698 qemu_deviceadd
($vmid, print_tabletdevice_full
($conf, $arch));
3700 } elsif ($deviceid eq 'keyboard') {
3702 qemu_deviceadd
($vmid, print_keyboarddevice_full
($conf, $arch));
3704 } elsif ($deviceid =~ m/^usb(\d+)$/) {
3706 die "usb hotplug currently not reliable\n";
3707 # since we can't reliably hot unplug all added usb devices
3708 # and usb passthrough disables live migration
3709 # we disable usb hotplugging for now
3710 qemu_deviceadd
($vmid, PVE
::QemuServer
::USB
::print_usbdevice_full
($conf, $deviceid, $device));
3712 } elsif ($deviceid =~ m/^(virtio)(\d+)$/) {
3714 qemu_iothread_add
($vmid, $deviceid, $device);
3716 qemu_driveadd
($storecfg, $vmid, $device);
3717 my $devicefull = print_drivedevice_full
($storecfg, $conf, $vmid, $device, $arch, $machine_type);
3719 qemu_deviceadd
($vmid, $devicefull);
3720 eval { qemu_deviceaddverify
($vmid, $deviceid); };
3722 eval { qemu_drivedel
($vmid, $deviceid); };
3727 } elsif ($deviceid =~ m/^(virtioscsi|scsihw)(\d+)$/) {
3730 my $scsihw = defined($conf->{scsihw
}) ?
$conf->{scsihw
} : "lsi";
3731 my $pciaddr = print_pci_addr
($deviceid, undef, $arch, $machine_type);
3732 my $scsihw_type = $scsihw eq 'virtio-scsi-single' ?
"virtio-scsi-pci" : $scsihw;
3734 my $devicefull = "$scsihw_type,id=$deviceid$pciaddr";
3736 if($deviceid =~ m/^virtioscsi(\d+)$/ && $device->{iothread
}) {
3737 qemu_iothread_add
($vmid, $deviceid, $device);
3738 $devicefull .= ",iothread=iothread-$deviceid";
3741 if($deviceid =~ m/^virtioscsi(\d+)$/ && $device->{queues
}) {
3742 $devicefull .= ",num_queues=$device->{queues}";
3745 qemu_deviceadd
($vmid, $devicefull);
3746 qemu_deviceaddverify
($vmid, $deviceid);
3748 } elsif ($deviceid =~ m/^(scsi)(\d+)$/) {
3750 qemu_findorcreatescsihw
($storecfg,$conf, $vmid, $device, $arch, $machine_type);
3751 qemu_driveadd
($storecfg, $vmid, $device);
3753 my $devicefull = print_drivedevice_full
($storecfg, $conf, $vmid, $device, $arch, $machine_type);
3754 eval { qemu_deviceadd
($vmid, $devicefull); };
3756 eval { qemu_drivedel
($vmid, $deviceid); };
3761 } elsif ($deviceid =~ m/^(net)(\d+)$/) {
3763 return undef if !qemu_netdevadd
($vmid, $conf, $arch, $device, $deviceid);
3765 my $machine_type = PVE
::QemuServer
::Machine
::qemu_machine_pxe
($vmid, $conf);
3766 my $use_old_bios_files = undef;
3767 ($use_old_bios_files, $machine_type) = qemu_use_old_bios_files
($machine_type);
3769 my $netdevicefull = print_netdevice_full
($vmid, $conf, $device, $deviceid, undef, $use_old_bios_files, $arch, $machine_type);
3770 qemu_deviceadd
($vmid, $netdevicefull);
3772 qemu_deviceaddverify
($vmid, $deviceid);
3773 qemu_set_link_status
($vmid, $deviceid, !$device->{link_down
});
3776 eval { qemu_netdevdel
($vmid, $deviceid); };
3781 } elsif (!$q35 && $deviceid =~ m/^(pci\.)(\d+)$/) {
3784 my $pciaddr = print_pci_addr
($deviceid, undef, $arch, $machine_type);
3785 my $devicefull = "pci-bridge,id=pci.$bridgeid,chassis_nr=$bridgeid$pciaddr";
3787 qemu_deviceadd
($vmid, $devicefull);
3788 qemu_deviceaddverify
($vmid, $deviceid);
3791 die "can't hotplug device '$deviceid'\n";
3797 # fixme: this should raise exceptions on error!
3798 sub vm_deviceunplug
{
3799 my ($vmid, $conf, $deviceid) = @_;
3801 my $devices_list = vm_devices_list
($vmid);
3802 return 1 if !defined($devices_list->{$deviceid});
3804 die "can't unplug bootdisk" if $conf->{bootdisk
} && $conf->{bootdisk
} eq $deviceid;
3806 if ($deviceid eq 'tablet' || $deviceid eq 'keyboard') {
3808 qemu_devicedel
($vmid, $deviceid);
3810 } elsif ($deviceid =~ m/^usb\d+$/) {
3812 die "usb hotplug currently not reliable\n";
3813 # when unplugging usb devices this way,
3814 # there may be remaining usb controllers/hubs
3815 # so we disable it for now
3816 qemu_devicedel
($vmid, $deviceid);
3817 qemu_devicedelverify
($vmid, $deviceid);
3819 } elsif ($deviceid =~ m/^(virtio)(\d+)$/) {
3821 qemu_devicedel
($vmid, $deviceid);
3822 qemu_devicedelverify
($vmid, $deviceid);
3823 qemu_drivedel
($vmid, $deviceid);
3824 qemu_iothread_del
($conf, $vmid, $deviceid);
3826 } elsif ($deviceid =~ m/^(virtioscsi|scsihw)(\d+)$/) {
3828 qemu_devicedel
($vmid, $deviceid);
3829 qemu_devicedelverify
($vmid, $deviceid);
3830 qemu_iothread_del
($conf, $vmid, $deviceid);
3832 } elsif ($deviceid =~ m/^(scsi)(\d+)$/) {
3834 qemu_devicedel
($vmid, $deviceid);
3835 qemu_drivedel
($vmid, $deviceid);
3836 qemu_deletescsihw
($conf, $vmid, $deviceid);
3838 } elsif ($deviceid =~ m/^(net)(\d+)$/) {
3840 qemu_devicedel
($vmid, $deviceid);
3841 qemu_devicedelverify
($vmid, $deviceid);
3842 qemu_netdevdel
($vmid, $deviceid);
3845 die "can't unplug device '$deviceid'\n";
3851 sub qemu_deviceadd
{
3852 my ($vmid, $devicefull) = @_;
3854 $devicefull = "driver=".$devicefull;
3855 my %options = split(/[=,]/, $devicefull);
3857 mon_cmd
($vmid, "device_add" , %options);
3860 sub qemu_devicedel
{
3861 my ($vmid, $deviceid) = @_;
3863 my $ret = mon_cmd
($vmid, "device_del", id
=> $deviceid);
3866 sub qemu_iothread_add
{
3867 my($vmid, $deviceid, $device) = @_;
3869 if ($device->{iothread
}) {
3870 my $iothreads = vm_iothreads_list
($vmid);
3871 qemu_objectadd
($vmid, "iothread-$deviceid", "iothread") if !$iothreads->{"iothread-$deviceid"};
3875 sub qemu_iothread_del
{
3876 my($conf, $vmid, $deviceid) = @_;
3878 my $confid = $deviceid;
3879 if ($deviceid =~ m/^(?:virtioscsi|scsihw)(\d+)$/) {
3880 $confid = 'scsi' . $1;
3882 my $device = parse_drive
($confid, $conf->{$confid});
3883 if ($device->{iothread
}) {
3884 my $iothreads = vm_iothreads_list
($vmid);
3885 qemu_objectdel
($vmid, "iothread-$deviceid") if $iothreads->{"iothread-$deviceid"};
3889 sub qemu_objectadd
{
3890 my($vmid, $objectid, $qomtype) = @_;
3892 mon_cmd
($vmid, "object-add", id
=> $objectid, "qom-type" => $qomtype);
3897 sub qemu_objectdel
{
3898 my($vmid, $objectid) = @_;
3900 mon_cmd
($vmid, "object-del", id
=> $objectid);
3906 my ($storecfg, $vmid, $device) = @_;
3908 my $drive = print_drive_commandline_full
($storecfg, $vmid, $device);
3909 $drive =~ s/\\/\\\\/g;
3910 my $ret = PVE
::QemuServer
::Monitor
::hmp_cmd
($vmid, "drive_add auto \"$drive\"");
3912 # If the command succeeds qemu prints: "OK
"
3913 return 1 if $ret =~ m/OK/s;
3915 die "adding drive failed
: $ret\n";
3919 my($vmid, $deviceid) = @_;
3921 my $ret = PVE::QemuServer::Monitor::hmp_cmd($vmid, "drive_del drive-
$deviceid");
3924 return 1 if $ret eq "";
3926 # NB: device not found errors mean the drive was auto-deleted and we ignore the error
3927 return 1 if $ret =~ m/Device \'.*?\' not found/s;
3929 die "deleting drive
$deviceid failed
: $ret\n";
3932 sub qemu_deviceaddverify {
3933 my ($vmid, $deviceid) = @_;
3935 for (my $i = 0; $i <= 5; $i++) {
3936 my $devices_list = vm_devices_list($vmid);
3937 return 1 if defined($devices_list->{$deviceid});
3941 die "error on hotplug device
'$deviceid'\n";
3945 sub qemu_devicedelverify {
3946 my ($vmid, $deviceid) = @_;
3948 # need to verify that the device is correctly removed as device_del
3949 # is async and empty return is not reliable
3951 for (my $i = 0; $i <= 5; $i++) {
3952 my $devices_list = vm_devices_list($vmid);
3953 return 1 if !defined($devices_list->{$deviceid});
3957 die "error on hot-unplugging device
'$deviceid'\n";
3960 sub qemu_findorcreatescsihw {
3961 my ($storecfg, $conf, $vmid, $device, $arch, $machine_type) = @_;
3963 my ($maxdev, $controller, $controller_prefix) = scsihw_infos($conf, $device);
3965 my $scsihwid="$controller_prefix$controller";
3966 my $devices_list = vm_devices_list($vmid);
3968 if(!defined($devices_list->{$scsihwid})) {
3969 vm_deviceplug($storecfg, $conf, $vmid, $scsihwid, $device, $arch, $machine_type);
3975 sub qemu_deletescsihw {
3976 my ($conf, $vmid, $opt) = @_;
3978 my $device = parse_drive($opt, $conf->{$opt});
3980 if ($conf->{scsihw} && ($conf->{scsihw} eq 'virtio-scsi-single')) {
3981 vm_deviceunplug($vmid, $conf, "virtioscsi
$device->{index}");
3985 my ($maxdev, $controller, $controller_prefix) = scsihw_infos($conf, $device);
3987 my $devices_list = vm_devices_list($vmid);
3988 foreach my $opt (keys %{$devices_list}) {
3989 if (is_valid_drivename($opt)) {
3990 my $drive = parse_drive($opt, $conf->{$opt});
3991 if($drive->{interface} eq 'scsi' && $drive->{index} < (($maxdev-1)*($controller+1))) {
3997 my $scsihwid="scsihw
$controller";
3999 vm_deviceunplug($vmid, $conf, $scsihwid);
4004 sub qemu_add_pci_bridge {
4005 my ($storecfg, $conf, $vmid, $device, $arch, $machine_type) = @_;
4011 print_pci_addr($device, $bridges, $arch, $machine_type);
4013 while (my ($k, $v) = each %$bridges) {
4016 return 1 if !defined($bridgeid) || $bridgeid < 1;
4018 my $bridge = "pci
.$bridgeid";
4019 my $devices_list = vm_devices_list($vmid);
4021 if (!defined($devices_list->{$bridge})) {
4022 vm_deviceplug($storecfg, $conf, $vmid, $bridge, $arch, $machine_type);
4028 sub qemu_set_link_status {
4029 my ($vmid, $device, $up) = @_;
4031 mon_cmd($vmid, "set_link
", name => $device,
4032 up => $up ? JSON::true : JSON::false);
4035 sub qemu_netdevadd {
4036 my ($vmid, $conf, $arch, $device, $deviceid) = @_;
4038 my $netdev = print_netdev_full($vmid, $conf, $arch, $device, $deviceid, 1);
4039 my %options = split(/[=,]/, $netdev);
4041 mon_cmd($vmid, "netdev_add
", %options);
4045 sub qemu_netdevdel {
4046 my ($vmid, $deviceid) = @_;
4048 mon_cmd($vmid, "netdev_del
", id => $deviceid);
4051 sub qemu_usb_hotplug {
4052 my ($storecfg, $conf, $vmid, $deviceid, $device, $arch, $machine_type) = @_;
4056 # remove the old one first
4057 vm_deviceunplug($vmid, $conf, $deviceid);
4059 # check if xhci controller is necessary and available
4060 if ($device->{usb3}) {
4062 my $devicelist = vm_devices_list($vmid);
4064 if (!$devicelist->{xhci}) {
4065 my $pciaddr = print_pci_addr("xhci
", undef, $arch, $machine_type);
4066 qemu_deviceadd($vmid, "nec-usb-xhci
,id
=xhci
$pciaddr");
4069 my $d = parse_usb_device($device->{host});
4070 $d->{usb3} = $device->{usb3};
4073 vm_deviceplug($storecfg, $conf, $vmid, $deviceid, $d, $arch, $machine_type);
4076 sub qemu_cpu_hotplug {
4077 my ($vmid, $conf, $vcpus) = @_;
4079 my $machine_type = PVE::QemuServer::Machine::get_current_qemu_machine($vmid);
4082 $sockets = $conf->{smp} if $conf->{smp}; # old style - no longer iused
4083 $sockets = $conf->{sockets} if $conf->{sockets};
4084 my $cores = $conf->{cores} || 1;
4085 my $maxcpus = $sockets * $cores;
4087 $vcpus = $maxcpus if !$vcpus;
4089 die "you can
't add more vcpus than maxcpus\n"
4090 if $vcpus > $maxcpus;
4092 my $currentvcpus = $conf->{vcpus} || $maxcpus;
4094 if ($vcpus < $currentvcpus) {
4096 if (PVE::QemuServer::Machine::machine_version($machine_type, 2, 7)) {
4098 for (my $i = $currentvcpus; $i > $vcpus; $i--) {
4099 qemu_devicedel($vmid, "cpu$i");
4101 my $currentrunningvcpus = undef;
4103 $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4104 last if scalar(@{$currentrunningvcpus}) == $i-1;
4105 raise_param_exc({ vcpus => "error unplugging cpu$i" }) if $retry > 5;
4109 #update conf after each succesfull cpu unplug
4110 $conf->{vcpus} = scalar(@{$currentrunningvcpus});
4111 PVE::QemuConfig->write_config($vmid, $conf);
4114 die "cpu hot-unplugging requires qemu version 2.7 or higher\n";
4120 my $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4121 die "vcpus in running vm does not match its configuration\n"
4122 if scalar(@{$currentrunningvcpus}) != $currentvcpus;
4124 if (PVE::QemuServer::Machine::machine_version($machine_type, 2, 7)) {
4126 for (my $i = $currentvcpus+1; $i <= $vcpus; $i++) {
4127 my $cpustr = print_cpu_device($conf, $i);
4128 qemu_deviceadd($vmid, $cpustr);
4131 my $currentrunningvcpus = undef;
4133 $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4134 last if scalar(@{$currentrunningvcpus}) == $i;
4135 raise_param_exc({ vcpus => "error hotplugging cpu$i" }) if $retry > 10;
4139 #update conf after each succesfull cpu hotplug
4140 $conf->{vcpus} = scalar(@{$currentrunningvcpus});
4141 PVE::QemuConfig->write_config($vmid, $conf);
4145 for (my $i = $currentvcpus; $i < $vcpus; $i++) {
4146 mon_cmd($vmid, "cpu-add", id => int($i));
4151 sub qemu_block_set_io_throttle {
4152 my ($vmid, $deviceid,
4153 $bps, $bps_rd, $bps_wr, $iops, $iops_rd, $iops_wr,
4154 $bps_max, $bps_rd_max, $bps_wr_max, $iops_max, $iops_rd_max, $iops_wr_max,
4155 $bps_max_length, $bps_rd_max_length, $bps_wr_max_length,
4156 $iops_max_length, $iops_rd_max_length, $iops_wr_max_length) = @_;
4158 return if !check_running($vmid) ;
4160 mon_cmd($vmid, "block_set_io_throttle", device => $deviceid,
4162 bps_rd => int($bps_rd),
4163 bps_wr => int($bps_wr),
4165 iops_rd => int($iops_rd),
4166 iops_wr => int($iops_wr),
4167 bps_max => int($bps_max),
4168 bps_rd_max => int($bps_rd_max),
4169 bps_wr_max => int($bps_wr_max),
4170 iops_max => int($iops_max),
4171 iops_rd_max => int($iops_rd_max),
4172 iops_wr_max => int($iops_wr_max),
4173 bps_max_length => int($bps_max_length),
4174 bps_rd_max_length => int($bps_rd_max_length),
4175 bps_wr_max_length => int($bps_wr_max_length),
4176 iops_max_length => int($iops_max_length),
4177 iops_rd_max_length => int($iops_rd_max_length),
4178 iops_wr_max_length => int($iops_wr_max_length),
4183 # old code, only used to shutdown old VM after update
4185 my ($fh, $timeout) = @_;
4187 my $sel = new IO::Select;
4194 while (scalar (@ready = $sel->can_read($timeout))) {
4196 if ($count = $fh->sysread($buf, 8192)) {
4197 if ($buf =~ /^(.*)\(qemu\) $/s) {
4204 if (!defined($count)) {
4211 die "monitor read timeout\n" if !scalar(@ready);
4216 sub qemu_block_resize {
4217 my ($vmid, $deviceid, $storecfg, $volid, $size) = @_;
4219 my $running = check_running($vmid);
4221 $size = 0 if !PVE::Storage::volume_resize($storecfg, $volid, $size, $running);
4223 return if !$running;
4225 my $padding = (1024 - $size % 1024) % 1024;
4226 $size = $size + $padding;
4228 mon_cmd($vmid, "block_resize", device => $deviceid, size => int($size));
4232 sub qemu_volume_snapshot {
4233 my ($vmid, $deviceid, $storecfg, $volid, $snap) = @_;
4235 my $running = check_running($vmid);
4237 if ($running && do_snapshots_with_qemu($storecfg, $volid)){
4238 mon_cmd($vmid, 'blockdev-snapshot-internal-sync
', device => $deviceid, name => $snap);
4240 PVE::Storage::volume_snapshot($storecfg, $volid, $snap);
4244 sub qemu_volume_snapshot_delete {
4245 my ($vmid, $deviceid, $storecfg, $volid, $snap) = @_;
4247 my $running = check_running($vmid);
4252 my $conf = PVE::QemuConfig->load_config($vmid);
4253 foreach_drive($conf, sub {
4254 my ($ds, $drive) = @_;
4255 $running = 1 if $drive->{file} eq $volid;
4259 if ($running && do_snapshots_with_qemu($storecfg, $volid)){
4260 mon_cmd($vmid, 'blockdev-snapshot-delete-internal-sync
', device => $deviceid, name => $snap);
4262 PVE::Storage::volume_snapshot_delete($storecfg, $volid, $snap, $running);
4266 sub set_migration_caps {
4272 "auto-converge" => 1,
4274 "x-rdma-pin-all" => 0,
4279 my $supported_capabilities = mon_cmd($vmid, "query-migrate-capabilities");
4281 for my $supported_capability (@$supported_capabilities) {
4283 capability => $supported_capability->{capability},
4284 state => $enabled_cap->{$supported_capability->{capability}} ? JSON::true : JSON::false,
4288 mon_cmd($vmid, "migrate-set-capabilities", capabilities => $cap_ref);
4291 my $fast_plug_option = {
4299 'vmstatestorage
' => 1,
4304 # hotplug changes in [PENDING]
4305 # $selection hash can be used to only apply specified options, for
4306 # example: { cores => 1 } (only apply changed 'cores
')
4307 # $errors ref is used to return error messages
4308 sub vmconfig_hotplug_pending {
4309 my ($vmid, $conf, $storecfg, $selection, $errors) = @_;
4311 my $defaults = load_defaults();
4312 my $arch = get_vm_arch($conf);
4313 my $machine_type = get_vm_machine($conf, undef, $arch);
4315 # commit values which do not have any impact on running VM first
4316 # Note: those option cannot raise errors, we we do not care about
4317 # $selection and always apply them.
4319 my $add_error = sub {
4320 my ($opt, $msg) = @_;
4321 $errors->{$opt} = "hotplug problem - $msg";
4325 foreach my $opt (keys %{$conf->{pending}}) { # add/change
4326 if ($fast_plug_option->{$opt}) {
4327 $conf->{$opt} = $conf->{pending}->{$opt};
4328 delete $conf->{pending}->{$opt};
4334 PVE::QemuConfig->write_config($vmid, $conf);
4337 my $hotplug_features = parse_hotplug_features(defined($conf->{hotplug}) ? $conf->{hotplug} : '1');
4339 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4340 foreach my $opt (sort keys %$pending_delete_hash) {
4341 next if $selection && !$selection->{$opt};
4342 my $force = $pending_delete_hash->{$opt}->{force};
4344 if ($opt eq 'hotplug
') {
4345 die "skip\n" if ($conf->{hotplug} =~ /memory/);
4346 } elsif ($opt eq 'tablet
') {
4347 die "skip\n" if !$hotplug_features->{usb};
4348 if ($defaults->{tablet}) {
4349 vm_deviceplug($storecfg, $conf, $vmid, 'tablet
', $arch, $machine_type);
4350 vm_deviceplug($storecfg, $conf, $vmid, 'keyboard
', $arch, $machine_type)
4351 if $arch eq 'aarch64
';
4353 vm_deviceunplug($vmid, $conf, 'tablet
');
4354 vm_deviceunplug($vmid, $conf, 'keyboard
') if $arch eq 'aarch64
';
4356 } elsif ($opt =~ m/^usb\d+/) {
4358 # since we cannot reliably hot unplug usb devices
4359 # we are disabling it
4360 die "skip\n" if !$hotplug_features->{usb} || $conf->{$opt} =~ m/spice/i;
4361 vm_deviceunplug($vmid, $conf, $opt);
4362 } elsif ($opt eq 'vcpus
') {
4363 die "skip\n" if !$hotplug_features->{cpu};
4364 qemu_cpu_hotplug($vmid, $conf, undef);
4365 } elsif ($opt eq 'balloon
') {
4366 # enable balloon device is not hotpluggable
4367 die "skip\n" if defined($conf->{balloon}) && $conf->{balloon} == 0;
4368 # here we reset the ballooning value to memory
4369 my $balloon = $conf->{memory} || $defaults->{memory};
4370 mon_cmd($vmid, "balloon", value => $balloon*1024*1024);
4371 } elsif ($fast_plug_option->{$opt}) {
4373 } elsif ($opt =~ m/^net(\d+)$/) {
4374 die "skip\n" if !$hotplug_features->{network};
4375 vm_deviceunplug($vmid, $conf, $opt);
4376 } elsif (is_valid_drivename($opt)) {
4377 die "skip\n" if !$hotplug_features->{disk} || $opt =~ m/(ide|sata)(\d+)/;
4378 vm_deviceunplug($vmid, $conf, $opt);
4379 vmconfig_delete_or_detach_drive($vmid, $storecfg, $conf, $opt, $force);
4380 } elsif ($opt =~ m/^memory$/) {
4381 die "skip\n" if !$hotplug_features->{memory};
4382 PVE::QemuServer::Memory::qemu_memory_hotplug($vmid, $conf, $defaults, $opt);
4383 } elsif ($opt eq 'cpuunits
') {
4384 cgroups_write("cpu", $vmid, "cpu.shares", $defaults->{cpuunits});
4385 } elsif ($opt eq 'cpulimit
') {
4386 cgroups_write("cpu", $vmid, "cpu.cfs_quota_us", -1);
4392 &$add_error($opt, $err) if $err ne "skip\n";
4394 delete $conf->{$opt};
4395 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4399 my ($apply_pending_cloudinit, $apply_pending_cloudinit_done);
4400 $apply_pending_cloudinit = sub {
4401 return if $apply_pending_cloudinit_done; # once is enough
4402 $apply_pending_cloudinit_done = 1; # once is enough
4404 my ($key, $value) = @_;
4406 my @cloudinit_opts = keys %$confdesc_cloudinit;
4407 foreach my $opt (keys %{$conf->{pending}}) {
4408 next if !grep { $_ eq $opt } @cloudinit_opts;
4409 $conf->{$opt} = delete $conf->{pending}->{$opt};
4412 my $new_conf = { %$conf };
4413 $new_conf->{$key} = $value;
4414 PVE::QemuServer::Cloudinit::generate_cloudinitconfig($new_conf, $vmid);
4417 foreach my $opt (keys %{$conf->{pending}}) {
4418 next if $selection && !$selection->{$opt};
4419 my $value = $conf->{pending}->{$opt};
4421 if ($opt eq 'hotplug
') {
4422 die "skip\n" if ($value =~ /memory/) || ($value !~ /memory/ && $conf->{hotplug} =~ /memory/);
4423 } elsif ($opt eq 'tablet
') {
4424 die "skip\n" if !$hotplug_features->{usb};
4426 vm_deviceplug($storecfg, $conf, $vmid, 'tablet
', $arch, $machine_type);
4427 vm_deviceplug($storecfg, $conf, $vmid, 'keyboard
', $arch, $machine_type)
4428 if $arch eq 'aarch64
';
4429 } elsif ($value == 0) {
4430 vm_deviceunplug($vmid, $conf, 'tablet
');
4431 vm_deviceunplug($vmid, $conf, 'keyboard
') if $arch eq 'aarch64
';
4433 } elsif ($opt =~ m/^usb\d+$/) {
4435 # since we cannot reliably hot unplug usb devices
4436 # we are disabling it
4437 die "skip\n" if !$hotplug_features->{usb} || $value =~ m/spice/i;
4438 my $d = eval { PVE::JSONSchema::parse_property_string($usbdesc->{format}, $value) };
4439 die "skip\n" if !$d;
4440 qemu_usb_hotplug($storecfg, $conf, $vmid, $opt, $d, $arch, $machine_type);
4441 } elsif ($opt eq 'vcpus
') {
4442 die "skip\n" if !$hotplug_features->{cpu};
4443 qemu_cpu_hotplug($vmid, $conf, $value);
4444 } elsif ($opt eq 'balloon
') {
4445 # enable/disable balloning device is not hotpluggable
4446 my $old_balloon_enabled = !!(!defined($conf->{balloon}) || $conf->{balloon});
4447 my $new_balloon_enabled = !!(!defined($conf->{pending}->{balloon}) || $conf->{pending}->{balloon});
4448 die "skip\n" if $old_balloon_enabled != $new_balloon_enabled;
4450 # allow manual ballooning if shares is set to zero
4451 if ((defined($conf->{shares}) && ($conf->{shares} == 0))) {
4452 my $balloon = $conf->{pending}->{balloon} || $conf->{memory} || $defaults->{memory};
4453 mon_cmd($vmid, "balloon", value => $balloon*1024*1024);
4455 } elsif ($opt =~ m/^net(\d+)$/) {
4456 # some changes can be done without hotplug
4457 vmconfig_update_net($storecfg, $conf, $hotplug_features->{network},
4458 $vmid, $opt, $value, $arch, $machine_type);
4459 } elsif (is_valid_drivename($opt)) {
4460 die "skip\n" if $opt eq 'efidisk0
';
4461 # some changes can be done without hotplug
4462 my $drive = parse_drive($opt, $value);
4463 if (drive_is_cloudinit($drive)) {
4464 &$apply_pending_cloudinit($opt, $value);
4466 vmconfig_update_disk($storecfg, $conf, $hotplug_features->{disk},
4467 $vmid, $opt, $value, $arch, $machine_type);
4468 } elsif ($opt =~ m/^memory$/) { #dimms
4469 die "skip\n" if !$hotplug_features->{memory};
4470 $value = PVE::QemuServer::Memory::qemu_memory_hotplug($vmid, $conf, $defaults, $opt, $value);
4471 } elsif ($opt eq 'cpuunits
') {
4472 cgroups_write("cpu", $vmid, "cpu.shares", $conf->{pending}->{$opt});
4473 } elsif ($opt eq 'cpulimit
') {
4474 my $cpulimit = $conf->{pending}->{$opt} == 0 ? -1 : int($conf->{pending}->{$opt} * 100000);
4475 cgroups_write("cpu", $vmid, "cpu.cfs_quota_us", $cpulimit);
4477 die "skip\n"; # skip non-hot-pluggable options
4481 &$add_error($opt, $err) if $err ne "skip\n";
4483 $conf->{$opt} = $value;
4484 delete $conf->{pending}->{$opt};
4488 PVE::QemuConfig->write_config($vmid, $conf);
4491 sub try_deallocate_drive {
4492 my ($storecfg, $vmid, $conf, $key, $drive, $rpcenv, $authuser, $force) = @_;
4494 if (($force || $key =~ /^unused/) && !drive_is_cdrom($drive, 1)) {
4495 my $volid = $drive->{file};
4496 if (vm_is_volid_owner($storecfg, $vmid, $volid)) {
4497 my $sid = PVE::Storage::parse_volume_id($volid);
4498 $rpcenv->check($authuser, "/storage/$sid", ['Datastore
.AllocateSpace
']);
4500 # check if the disk is really unused
4501 die "unable to delete '$volid' - volume is still in use (snapshot?)\n"
4502 if PVE::QemuServer::Drive::is_volume_in_use($storecfg, $conf, $key, $volid);
4503 PVE::Storage::vdisk_free($storecfg, $volid);
4506 # If vm is not owner of this disk remove from config
4514 sub vmconfig_delete_or_detach_drive {
4515 my ($vmid, $storecfg, $conf, $opt, $force) = @_;
4517 my $drive = parse_drive($opt, $conf->{$opt});
4519 my $rpcenv = PVE::RPCEnvironment::get();
4520 my $authuser = $rpcenv->get_user();
4523 $rpcenv->check_vm_perm($authuser, $vmid, undef, ['VM
.Config
.Disk
']);
4524 try_deallocate_drive($storecfg, $vmid, $conf, $opt, $drive, $rpcenv, $authuser, $force);
4526 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $drive);
4532 sub vmconfig_apply_pending {
4533 my ($vmid, $conf, $storecfg, $errors) = @_;
4535 my $add_apply_error = sub {
4536 my ($opt, $msg) = @_;
4537 my $err_msg = "unable to apply pending change $opt : $msg";
4538 $errors->{$opt} = $err_msg;
4544 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4545 foreach my $opt (sort keys %$pending_delete_hash) {
4546 my $force = $pending_delete_hash->{$opt}->{force};
4548 if ($opt =~ m/^unused/) {
4549 die "internal error";
4550 } elsif (defined($conf->{$opt}) && is_valid_drivename($opt)) {
4551 vmconfig_delete_or_detach_drive($vmid, $storecfg, $conf, $opt, $force);
4555 $add_apply_error->($opt, $err);
4557 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4558 delete $conf->{$opt};
4562 PVE::QemuConfig->cleanup_pending($conf);
4564 foreach my $opt (keys %{$conf->{pending}}) { # add/change
4565 next if $opt eq 'delete'; # just to be sure
4567 if (defined($conf->{$opt}) && is_valid_drivename($opt)) {
4568 vmconfig_register_unused_drive($storecfg, $vmid, $conf, parse_drive($opt, $conf->{$opt}))
4572 $add_apply_error->($opt, $err);
4574 $conf->{$opt} = delete $conf->{pending}->{$opt};
4578 # write all changes at once to avoid unnecessary i/o
4579 PVE::QemuConfig->write_config($vmid, $conf);
4582 sub vmconfig_update_net {
4583 my ($storecfg, $conf, $hotplug, $vmid, $opt, $value, $arch, $machine_type) = @_;
4585 my $newnet = parse_net($value);
4587 if ($conf->{$opt}) {
4588 my $oldnet = parse_net($conf->{$opt});
4590 if (safe_string_ne($oldnet->{model}, $newnet->{model}) ||
4591 safe_string_ne($oldnet->{macaddr}, $newnet->{macaddr}) ||
4592 safe_num_ne($oldnet->{queues}, $newnet->{queues}) ||
4593 !($newnet->{bridge} && $oldnet->{bridge})) { # bridge/nat mode change
4595 # for non online change, we try to hot-unplug
4596 die "skip\n" if !$hotplug;
4597 vm_deviceunplug($vmid, $conf, $opt);
4600 die "internal error" if $opt !~ m/net(\d+)/;
4601 my $iface = "tap${vmid}i$1";
4603 if (safe_string_ne($oldnet->{bridge}, $newnet->{bridge}) ||
4604 safe_num_ne($oldnet->{tag}, $newnet->{tag}) ||
4605 safe_string_ne($oldnet->{trunks}, $newnet->{trunks}) ||
4606 safe_num_ne($oldnet->{firewall}, $newnet->{firewall})) {
4607 PVE::Network::tap_unplug($iface);
4610 PVE::Network::SDN::Zones::tap_plug($iface, $newnet->{bridge}, $newnet->{tag}, $newnet->{firewall}, $newnet->{trunks}, $newnet->{rate});
4612 PVE::Network::tap_plug($iface, $newnet->{bridge}, $newnet->{tag}, $newnet->{firewall}, $newnet->{trunks}, $newnet->{rate});
4614 } elsif (safe_num_ne($oldnet->{rate}, $newnet->{rate})) {
4615 # Rate can be applied on its own but any change above needs to
4616 # include the rate in tap_plug since OVS resets everything.
4617 PVE::Network::tap_rate_limit($iface, $newnet->{rate});
4620 if (safe_string_ne($oldnet->{link_down}, $newnet->{link_down})) {
4621 qemu_set_link_status($vmid, $opt, !$newnet->{link_down});
4629 vm_deviceplug($storecfg, $conf, $vmid, $opt, $newnet, $arch, $machine_type);
4635 sub vmconfig_update_disk {
4636 my ($storecfg, $conf, $hotplug, $vmid, $opt, $value, $arch, $machine_type) = @_;
4638 my $drive = parse_drive($opt, $value);
4640 if ($conf->{$opt}) {
4642 if (my $old_drive = parse_drive($opt, $conf->{$opt})) {
4644 my $media = $drive->{media} || 'disk
';
4645 my $oldmedia = $old_drive->{media} || 'disk
';
4646 die "unable to change media type\n" if $media ne $oldmedia;
4648 if (!drive_is_cdrom($old_drive)) {
4650 if ($drive->{file} ne $old_drive->{file}) {
4652 die "skip\n" if !$hotplug;
4654 # unplug and register as unused
4655 vm_deviceunplug($vmid, $conf, $opt);
4656 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $old_drive)
4659 # update existing disk
4661 # skip non hotpluggable value
4662 if (safe_string_ne($drive->{discard}, $old_drive->{discard}) ||
4663 safe_string_ne($drive->{iothread}, $old_drive->{iothread}) ||
4664 safe_string_ne($drive->{queues}, $old_drive->{queues}) ||
4665 safe_string_ne($drive->{cache}, $old_drive->{cache}) ||
4666 safe_string_ne($drive->{ssd}, $old_drive->{ssd})) {
4671 if (safe_num_ne($drive->{mbps}, $old_drive->{mbps}) ||
4672 safe_num_ne($drive->{mbps_rd}, $old_drive->{mbps_rd}) ||
4673 safe_num_ne($drive->{mbps_wr}, $old_drive->{mbps_wr}) ||
4674 safe_num_ne($drive->{iops}, $old_drive->{iops}) ||
4675 safe_num_ne($drive->{iops_rd}, $old_drive->{iops_rd}) ||
4676 safe_num_ne($drive->{iops_wr}, $old_drive->{iops_wr}) ||
4677 safe_num_ne($drive->{mbps_max}, $old_drive->{mbps_max}) ||
4678 safe_num_ne($drive->{mbps_rd_max}, $old_drive->{mbps_rd_max}) ||
4679 safe_num_ne($drive->{mbps_wr_max}, $old_drive->{mbps_wr_max}) ||
4680 safe_num_ne($drive->{iops_max}, $old_drive->{iops_max}) ||
4681 safe_num_ne($drive->{iops_rd_max}, $old_drive->{iops_rd_max}) ||
4682 safe_num_ne($drive->{iops_wr_max}, $old_drive->{iops_wr_max}) ||
4683 safe_num_ne($drive->{bps_max_length}, $old_drive->{bps_max_length}) ||
4684 safe_num_ne($drive->{bps_rd_max_length}, $old_drive->{bps_rd_max_length}) ||
4685 safe_num_ne($drive->{bps_wr_max_length}, $old_drive->{bps_wr_max_length}) ||
4686 safe_num_ne($drive->{iops_max_length}, $old_drive->{iops_max_length}) ||
4687 safe_num_ne($drive->{iops_rd_max_length}, $old_drive->{iops_rd_max_length}) ||
4688 safe_num_ne($drive->{iops_wr_max_length}, $old_drive->{iops_wr_max_length})) {
4690 qemu_block_set_io_throttle($vmid,"drive-$opt",
4691 ($drive->{mbps} || 0)*1024*1024,
4692 ($drive->{mbps_rd} || 0)*1024*1024,
4693 ($drive->{mbps_wr} || 0)*1024*1024,
4694 $drive->{iops} || 0,
4695 $drive->{iops_rd} || 0,
4696 $drive->{iops_wr} || 0,
4697 ($drive->{mbps_max} || 0)*1024*1024,
4698 ($drive->{mbps_rd_max} || 0)*1024*1024,
4699 ($drive->{mbps_wr_max} || 0)*1024*1024,
4700 $drive->{iops_max} || 0,
4701 $drive->{iops_rd_max} || 0,
4702 $drive->{iops_wr_max} || 0,
4703 $drive->{bps_max_length} || 1,
4704 $drive->{bps_rd_max_length} || 1,
4705 $drive->{bps_wr_max_length} || 1,
4706 $drive->{iops_max_length} || 1,
4707 $drive->{iops_rd_max_length} || 1,
4708 $drive->{iops_wr_max_length} || 1);
4717 if ($drive->{file} eq 'none
') {
4718 mon_cmd($vmid, "eject", force => JSON::true, id => "$opt");
4719 if (drive_is_cloudinit($old_drive)) {
4720 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $old_drive);
4723 my $path = get_iso_path($storecfg, $vmid, $drive->{file});
4725 # force eject if locked
4726 mon_cmd($vmid, "eject", force => JSON::true, id => "$opt");
4729 mon_cmd($vmid, "blockdev-change-medium",
4730 id => "$opt", filename => "$path");
4739 die "skip\n" if !$hotplug || $opt =~ m/(ide|sata)(\d+)/;
4741 PVE::Storage::activate_volumes($storecfg, [$drive->{file}]) if $drive->{file} !~ m|^/dev/.+|;
4742 vm_deviceplug($storecfg, $conf, $vmid, $opt, $drive, $arch, $machine_type);
4745 # called in locked context by incoming migration
4746 sub vm_migrate_get_nbd_disks {
4747 my ($storecfg, $conf, $replicated_volumes) = @_;
4749 my $local_volumes = {};
4750 foreach_drive($conf, sub {
4751 my ($ds, $drive) = @_;
4753 return if drive_is_cdrom($drive);
4755 my $volid = $drive->{file};
4759 my ($storeid, $volname) = PVE::Storage::parse_volume_id($volid);
4761 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
4762 return if $scfg->{shared};
4764 # replicated disks re-use existing state via bitmap
4765 my $use_existing = $replicated_volumes->{$volid} ? 1 : 0;
4766 $local_volumes->{$ds} = [$volid, $storeid, $volname, $drive, $use_existing];
4768 return $local_volumes;
4771 # called in locked context by incoming migration
4772 sub vm_migrate_alloc_nbd_disks {
4773 my ($storecfg, $vmid, $source_volumes, $storagemap) = @_;
4778 foreach my $opt (sort keys %$source_volumes) {
4779 my ($volid, $storeid, $volname, $drive, $use_existing) = @{$source_volumes->{$opt}};
4781 if ($use_existing) {
4782 $nbd->{$opt}->{drivestr} = print_drive($drive);
4783 $nbd->{$opt}->{volid} = $volid;
4784 $nbd->{$opt}->{replicated} = 1;
4788 # If a remote storage is specified and the format of the original
4789 # volume is not available there, fall back to the default format.
4790 # Otherwise use the same format as the original.
4791 if (!$storagemap->{identity}) {
4792 $storeid = map_storage($storagemap, $storeid);
4793 my ($defFormat, $validFormats) = PVE::Storage::storage_default_format($storecfg, $storeid);
4794 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
4795 my $fileFormat = qemu_img_format($scfg, $volname);
4796 $format = (grep {$fileFormat eq $_} @{$validFormats}) ? $fileFormat : $defFormat;
4798 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
4799 $format = qemu_img_format($scfg, $volname);
4802 my $newvolid = PVE::Storage::vdisk_alloc($storecfg, $storeid, $vmid, $format, undef, ($drive->{size}/1024));
4803 my $newdrive = $drive;
4804 $newdrive->{format} = $format;
4805 $newdrive->{file} = $newvolid;
4806 my $drivestr = print_drive($newdrive);
4807 $nbd->{$opt}->{drivestr} = $drivestr;
4808 $nbd->{$opt}->{volid} = $newvolid;
4814 # see vm_start_nolock for parameters, additionally:
4816 # storagemap = parsed storage map for allocating NBD disks
4818 my ($storecfg, $vmid, $params, $migrate_opts) = @_;
4820 return PVE::QemuConfig->lock_config($vmid, sub {
4821 my $conf = PVE::QemuConfig->load_config($vmid, $migrate_opts->{migratedfrom});
4823 die "you can't start a vm
if it
's a template\n" if PVE::QemuConfig->is_template($conf);
4825 $params->{resume} = PVE::QemuConfig->has_lock($conf, 'suspended
');
4827 PVE::QemuConfig->check_lock($conf)
4828 if !($params->{skiplock} || $params->{resume});
4830 die "VM $vmid already running\n" if check_running($vmid, undef, $migrate_opts->{migratedfrom});
4832 if (my $storagemap = $migrate_opts->{storagemap}) {
4833 my $replicated = $migrate_opts->{replicated_volumes};
4834 my $disks = vm_migrate_get_nbd_disks($storecfg, $conf, $replicated);
4835 $migrate_opts->{nbd} = vm_migrate_alloc_nbd_disks($storecfg, $vmid, $disks, $storagemap);
4837 foreach my $opt (keys %{$migrate_opts->{nbd}}) {
4838 $conf->{$opt} = $migrate_opts->{nbd}->{$opt}->{drivestr};
4842 return vm_start_nolock($storecfg, $vmid, $conf, $params, $migrate_opts);
4848 # statefile => 'tcp
', 'unix
' for migration or path/volid for RAM state
4849 # skiplock => 0/1, skip checking for config lock
4850 # forcemachine => to force Qemu machine (rollback/migration)
4851 # forcecpu => a QEMU '-cpu
' argument string to override get_cpu_options
4852 # timeout => in seconds
4853 # paused => start VM in paused state (backup)
4854 # resume => resume from hibernation
4856 # nbd => volumes for NBD exports (vm_migrate_alloc_nbd_disks)
4857 # migratedfrom => source node
4858 # spice_ticket => used for spice migration, passed via tunnel/stdin
4859 # network => CIDR of migration network
4860 # type => secure/insecure - tunnel over encrypted connection or plain-text
4861 # nbd_proto_version => int, 0 for TCP, 1 for UNIX
4862 # replicated_volumes = which volids should be re-used with bitmaps for nbd migration
4863 sub vm_start_nolock {
4864 my ($storecfg, $vmid, $conf, $params, $migrate_opts) = @_;
4866 my $statefile = $params->{statefile};
4867 my $resume = $params->{resume};
4869 my $migratedfrom = $migrate_opts->{migratedfrom};
4870 my $migration_type = $migrate_opts->{type};
4874 # clean up leftover reboot request files
4875 eval { clear_reboot_request($vmid); };
4878 if (!$statefile && scalar(keys %{$conf->{pending}})) {
4879 vmconfig_apply_pending($vmid, $conf, $storecfg);
4880 $conf = PVE::QemuConfig->load_config($vmid); # update/reload
4883 PVE::QemuServer::Cloudinit::generate_cloudinitconfig($conf, $vmid);
4885 my $defaults = load_defaults();
4887 # set environment variable useful inside network script
4888 $ENV{PVE_MIGRATED_FROM} = $migratedfrom if $migratedfrom;
4890 PVE::GuestHelpers::exec_hookscript($conf, $vmid, 'pre-start
', 1);
4892 my $forcemachine = $params->{forcemachine};
4893 my $forcecpu = $params->{forcecpu};
4895 # enforce machine and CPU type on suspended vm to ensure HW compatibility
4896 $forcemachine = $conf->{runningmachine};
4897 $forcecpu = $conf->{runningcpu};
4898 print "Resuming suspended VM\n";
4901 my ($cmd, $vollist, $spice_port) =
4902 config_to_command($storecfg, $vmid, $conf, $defaults, $forcemachine, $forcecpu);
4905 my $get_migration_ip = sub {
4906 my ($nodename) = @_;
4908 return $migration_ip if defined($migration_ip);
4910 my $cidr = $migrate_opts->{network};
4912 if (!defined($cidr)) {
4913 my $dc_conf = PVE::Cluster::cfs_read_file('datacenter
.cfg
');
4914 $cidr = $dc_conf->{migration}->{network};
4917 if (defined($cidr)) {
4918 my $ips = PVE::Network::get_local_ip_from_cidr($cidr);
4920 die "could not get IP: no address configured on local " .
4921 "node for network '$cidr'\n" if scalar(@$ips) == 0;
4923 die "could not get IP: multiple addresses configured on local " .
4924 "node for network '$cidr'\n" if scalar(@$ips) > 1;
4926 $migration_ip = @$ips[0];
4929 $migration_ip = PVE::Cluster::remote_node_ip($nodename, 1)
4930 if !defined($migration_ip);
4932 return $migration_ip;
4937 if ($statefile eq 'tcp
') {
4938 my $localip = "localhost";
4939 my $datacenterconf = PVE::Cluster::cfs_read_file('datacenter
.cfg
');
4940 my $nodename = nodename();
4942 if (!defined($migration_type)) {
4943 if (defined($datacenterconf->{migration}->{type})) {
4944 $migration_type = $datacenterconf->{migration}->{type};
4946 $migration_type = 'secure
';
4950 if ($migration_type eq 'insecure
') {
4951 $localip = $get_migration_ip->($nodename);
4952 $localip = "[$localip]" if Net::IP::ip_is_ipv6($localip);
4955 my $pfamily = PVE::Tools::get_host_address_family($nodename);
4956 my $migrate_port = PVE::Tools::next_migrate_port($pfamily);
4957 $migrate_uri = "tcp:${localip}:${migrate_port}";
4958 push @$cmd, '-incoming
', $migrate_uri;
4961 } elsif ($statefile eq 'unix
') {
4962 # should be default for secure migrations as a ssh TCP forward
4963 # tunnel is not deterministic reliable ready and fails regurarly
4964 # to set up in time, so use UNIX socket forwards
4965 my $socket_addr = "/run/qemu-server/$vmid.migrate";
4966 unlink $socket_addr;
4968 $migrate_uri = "unix:$socket_addr";
4970 push @$cmd, '-incoming
', $migrate_uri;
4973 } elsif (-e $statefile) {
4974 push @$cmd, '-loadstate
', $statefile;
4976 my $statepath = PVE::Storage::path($storecfg, $statefile);
4977 push @$vollist, $statefile;
4978 push @$cmd, '-loadstate
', $statepath;
4980 } elsif ($params->{paused}) {
4985 for (my $i = 0; $i < $MAX_HOSTPCI_DEVICES; $i++) {
4986 my $d = parse_hostpci($conf->{"hostpci$i"});
4988 my $pcidevices = $d->{pciid};
4989 foreach my $pcidevice (@$pcidevices) {
4990 my $pciid = $pcidevice->{id};
4992 my $info = PVE::SysFSTools::pci_device_info("$pciid");
4993 die "IOMMU not present\n" if !PVE::SysFSTools::check_iommu_support();
4994 die "no pci device info for device '$pciid'\n" if !$info;
4997 my $uuid = PVE::SysFSTools::generate_mdev_uuid($vmid, $i);
4998 PVE::SysFSTools::pci_create_mdev_device($pciid, $uuid, $d->{mdev});
5000 die "can't unbind
/bind pci group to vfio
'$pciid'\n"
5001 if !PVE::SysFSTools::pci_dev_group_bind_to_vfio($pciid);
5002 die "can
't reset pci device '$pciid'\n"
5003 if $info->{has_fl_reset} and !PVE::SysFSTools::pci_dev_reset($info);
5008 PVE::Storage::activate_volumes($storecfg, $vollist);
5011 run_command(['/bin/systemctl
', 'stop
', "$vmid.scope"],
5012 outfunc => sub {}, errfunc => sub {});
5014 # Issues with the above 'stop
' not being fully completed are extremely rare, a very low
5015 # timeout should be more than enough here...
5016 PVE::Systemd::wait_for_unit_removed("$vmid.scope", 5);
5018 my $cpuunits = defined($conf->{cpuunits}) ? $conf->{cpuunits}
5019 : $defaults->{cpuunits};
5021 my $start_timeout = $params->{timeout} // config_aware_timeout($conf, $resume);
5023 timeout => $statefile ? undef : $start_timeout,
5028 # when migrating, prefix QEMU output so other side can pick up any
5029 # errors that might occur and show the user
5030 if ($migratedfrom) {
5031 $run_params{quiet} = 1;
5032 $run_params{logfunc} = sub { print "QEMU: $_[0]\n" };
5036 Slice => 'qemu
.slice
',
5038 CPUShares => $cpuunits
5041 if (my $cpulimit = $conf->{cpulimit}) {
5042 $properties{CPUQuota} = int($cpulimit * 100);
5044 $properties{timeout} = 10 if $statefile; # setting up the scope shoul be quick
5046 my $run_qemu = sub {
5047 PVE::Tools::run_fork sub {
5048 PVE::Systemd::enter_systemd_scope($vmid, "Proxmox VE VM $vmid", %properties);
5050 my $exitcode = run_command($cmd, %run_params);
5051 die "QEMU exited with code $exitcode\n" if $exitcode;
5055 if ($conf->{hugepages}) {
5058 my $hugepages_topology = PVE::QemuServer::Memory::hugepages_topology($conf);
5059 my $hugepages_host_topology = PVE::QemuServer::Memory::hugepages_host_topology();
5061 PVE::QemuServer::Memory::hugepages_mount();
5062 PVE::QemuServer::Memory::hugepages_allocate($hugepages_topology, $hugepages_host_topology);
5064 eval { $run_qemu->() };
5066 PVE::QemuServer::Memory::hugepages_reset($hugepages_host_topology);
5070 PVE::QemuServer::Memory::hugepages_pre_deallocate($hugepages_topology);
5072 eval { PVE::QemuServer::Memory::hugepages_update_locked($code); };
5075 eval { $run_qemu->() };
5079 # deactivate volumes if start fails
5080 eval { PVE::Storage::deactivate_volumes($storecfg, $vollist); };
5081 die "start failed: $err";
5084 print "migration listens on $migrate_uri\n" if $migrate_uri;
5085 $res->{migrate_uri} = $migrate_uri;
5087 if ($statefile && $statefile ne 'tcp
' && $statefile ne 'unix
') {
5088 eval { mon_cmd($vmid, "cont"); };
5092 #start nbd server for storage migration
5093 if (my $nbd = $migrate_opts->{nbd}) {
5094 my $nbd_protocol_version = $migrate_opts->{nbd_proto_version} // 0;
5096 my $migrate_storage_uri;
5097 # nbd_protocol_version > 0 for unix socket support
5098 if ($nbd_protocol_version > 0 && $migration_type eq 'secure
') {
5099 my $socket_path = "/run/qemu-server/$vmid\_nbd.migrate";
5100 mon_cmd($vmid, "nbd-server-start", addr => { type => 'unix
', data => { path => $socket_path } } );
5101 $migrate_storage_uri = "nbd:unix:$socket_path";
5103 my $nodename = nodename();
5104 my $localip = $get_migration_ip->($nodename);
5105 my $pfamily = PVE::Tools::get_host_address_family($nodename);
5106 my $storage_migrate_port = PVE::Tools::next_migrate_port($pfamily);
5108 mon_cmd($vmid, "nbd-server-start", addr => { type => 'inet
', data => { host => "${localip}", port => "${storage_migrate_port}" } } );
5109 $localip = "[$localip]" if Net::IP::ip_is_ipv6($localip);
5110 $migrate_storage_uri = "nbd:${localip}:${storage_migrate_port}";
5113 $res->{migrate_storage_uri} = $migrate_storage_uri;
5115 foreach my $opt (sort keys %$nbd) {
5116 my $drivestr = $nbd->{$opt}->{drivestr};
5117 my $volid = $nbd->{$opt}->{volid};
5118 mon_cmd($vmid, "nbd-server-add", device => "drive-$opt", writable => JSON::true );
5119 my $nbd_uri = "$migrate_storage_uri:exportname=drive-$opt";
5120 print "storage migration listens on $nbd_uri volume:$drivestr\n";
5121 print "re-using replicated volume: $opt - $volid\n"
5122 if $nbd->{$opt}->{replicated};
5124 $res->{drives}->{$opt} = $nbd->{$opt};
5125 $res->{drives}->{$opt}->{nbd_uri} = $nbd_uri;
5129 if ($migratedfrom) {
5131 set_migration_caps($vmid);
5136 print "spice listens on port $spice_port\n";
5137 $res->{spice_port} = $spice_port;
5138 if ($migrate_opts->{spice_ticket}) {
5139 mon_cmd($vmid, "set_password", protocol => 'spice
', password => $migrate_opts->{spice_ticket});
5140 mon_cmd($vmid, "expire_password", protocol => 'spice
', time => "+30");
5145 mon_cmd($vmid, "balloon", value => $conf->{balloon}*1024*1024)
5146 if !$statefile && $conf->{balloon};
5148 foreach my $opt (keys %$conf) {
5149 next if $opt !~ m/^net\d+$/;
5150 my $nicconf = parse_net($conf->{$opt});
5151 qemu_set_link_status($vmid, $opt, 0) if $nicconf->{link_down};
5155 mon_cmd($vmid, 'qom-set
',
5156 path => "machine/peripheral/balloon0",
5157 property => "guest-stats-polling-interval",
5158 value => 2) if (!defined($conf->{balloon}) || $conf->{balloon});
5161 print "Resumed VM, removing state\n";
5162 if (my $vmstate = $conf->{vmstate}) {
5163 PVE::Storage::deactivate_volumes($storecfg, [$vmstate]);
5164 PVE::Storage::vdisk_free($storecfg, $vmstate);
5166 delete $conf->@{qw(lock vmstate runningmachine runningcpu)};
5167 PVE
::QemuConfig-
>write_config($vmid, $conf);
5170 PVE
::GuestHelpers
::exec_hookscript
($conf, $vmid, 'post-start');
5175 sub vm_commandline
{
5176 my ($storecfg, $vmid, $snapname) = @_;
5178 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5183 my $snapshot = $conf->{snapshots
}->{$snapname};
5184 die "snapshot '$snapname' does not exist\n" if !defined($snapshot);
5186 # check for machine or CPU overrides in snapshot
5187 $forcemachine = $snapshot->{runningmachine
};
5188 $forcecpu = $snapshot->{runningcpu
};
5190 $snapshot->{digest
} = $conf->{digest
}; # keep file digest for API
5195 my $defaults = load_defaults
();
5197 my $cmd = config_to_command
($storecfg, $vmid, $conf, $defaults,
5198 $forcemachine, $forcecpu);
5200 return PVE
::Tools
::cmd2string
($cmd);
5204 my ($vmid, $skiplock) = @_;
5206 PVE
::QemuConfig-
>lock_config($vmid, sub {
5208 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5210 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
5212 mon_cmd
($vmid, "system_reset");
5216 sub get_vm_volumes
{
5220 foreach_volid
($conf, sub {
5221 my ($volid, $attr) = @_;
5223 return if $volid =~ m
|^/|;
5225 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
5228 push @$vollist, $volid;
5234 sub vm_stop_cleanup
{
5235 my ($storecfg, $vmid, $conf, $keepActive, $apply_pending_changes) = @_;
5240 my $vollist = get_vm_volumes
($conf);
5241 PVE
::Storage
::deactivate_volumes
($storecfg, $vollist);
5244 foreach my $ext (qw(mon qmp pid vnc qga)) {
5245 unlink "/var/run/qemu-server/${vmid}.$ext";
5248 if ($conf->{ivshmem
}) {
5249 my $ivshmem = PVE
::JSONSchema
::parse_property_string
($ivshmem_fmt, $conf->{ivshmem
});
5250 # just delete it for now, VMs which have this already open do not
5251 # are affected, but new VMs will get a separated one. If this
5252 # becomes an issue we either add some sort of ref-counting or just
5253 # add a "don't delete on stop" flag to the ivshmem format.
5254 unlink '/dev/shm/pve-shm-' . ($ivshmem->{name
} // $vmid);
5257 foreach my $key (keys %$conf) {
5258 next if $key !~ m/^hostpci(\d+)$/;
5259 my $hostpciindex = $1;
5260 my $d = parse_hostpci
($conf->{$key});
5261 my $uuid = PVE
::SysFSTools
::generate_mdev_uuid
($vmid, $hostpciindex);
5263 foreach my $pci (@{$d->{pciid
}}) {
5264 my $pciid = $pci->{id
};
5265 PVE
::SysFSTools
::pci_cleanup_mdev_device
($pciid, $uuid);
5269 vmconfig_apply_pending
($vmid, $conf, $storecfg) if $apply_pending_changes;
5271 warn $@ if $@; # avoid errors - just warn
5274 # call only in locked context
5276 my ($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive) = @_;
5278 my $pid = check_running
($vmid, $nocheck);
5283 $conf = PVE
::QemuConfig-
>load_config($vmid);
5284 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
5285 if (!defined($timeout) && $shutdown && $conf->{startup
}) {
5286 my $opts = PVE
::JSONSchema
::pve_parse_startup_order
($conf->{startup
});
5287 $timeout = $opts->{down
} if $opts->{down
};
5289 PVE
::GuestHelpers
::exec_hookscript
($conf, $vmid, 'pre-stop');
5294 if (defined($conf) && parse_guest_agent
($conf)->{enabled
}) {
5295 mon_cmd
($vmid, "guest-shutdown", timeout
=> $timeout);
5297 mon_cmd
($vmid, "system_powerdown");
5300 mon_cmd
($vmid, "quit");
5306 $timeout = 60 if !defined($timeout);
5309 while (($count < $timeout) && check_running
($vmid, $nocheck)) {
5314 if ($count >= $timeout) {
5316 warn "VM still running - terminating now with SIGTERM\n";
5319 die "VM quit/powerdown failed - got timeout\n";
5322 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 1) if $conf;
5327 warn "VM quit/powerdown failed - terminating now with SIGTERM\n";
5330 die "VM quit/powerdown failed\n";
5338 while (($count < $timeout) && check_running
($vmid, $nocheck)) {
5343 if ($count >= $timeout) {
5344 warn "VM still running - terminating now with SIGKILL\n";
5349 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 1) if $conf;
5352 # Note: use $nocheck to skip tests if VM configuration file exists.
5353 # We need that when migration VMs to other nodes (files already moved)
5354 # Note: we set $keepActive in vzdump stop mode - volumes need to stay active
5356 my ($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive, $migratedfrom) = @_;
5358 $force = 1 if !defined($force) && !$shutdown;
5361 my $pid = check_running
($vmid, $nocheck, $migratedfrom);
5362 kill 15, $pid if $pid;
5363 my $conf = PVE
::QemuConfig-
>load_config($vmid, $migratedfrom);
5364 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 0);
5368 PVE
::QemuConfig-
>lock_config($vmid, sub {
5369 _do_vm_stop
($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive);
5374 my ($vmid, $timeout) = @_;
5376 PVE
::QemuConfig-
>lock_config($vmid, sub {
5379 # only reboot if running, as qmeventd starts it again on a stop event
5380 return if !check_running
($vmid);
5382 create_reboot_request
($vmid);
5384 my $storecfg = PVE
::Storage
::config
();
5385 _do_vm_stop
($storecfg, $vmid, undef, undef, $timeout, 1);
5389 # avoid that the next normal shutdown will be confused for a reboot
5390 clear_reboot_request
($vmid);
5396 # note: if using the statestorage parameter, the caller has to check privileges
5398 my ($vmid, $skiplock, $includestate, $statestorage) = @_;
5405 PVE
::QemuConfig-
>lock_config($vmid, sub {
5407 $conf = PVE
::QemuConfig-
>load_config($vmid);
5409 my $is_backing_up = PVE
::QemuConfig-
>has_lock($conf, 'backup');
5410 PVE
::QemuConfig-
>check_lock($conf)
5411 if !($skiplock || $is_backing_up);
5413 die "cannot suspend to disk during backup\n"
5414 if $is_backing_up && $includestate;
5416 if ($includestate) {
5417 $conf->{lock} = 'suspending';
5418 my $date = strftime
("%Y-%m-%d", localtime(time()));
5419 $storecfg = PVE
::Storage
::config
();
5420 if (!$statestorage) {
5421 $statestorage = find_vmstate_storage
($conf, $storecfg);
5422 # check permissions for the storage
5423 my $rpcenv = PVE
::RPCEnvironment
::get
();
5424 if ($rpcenv->{type
} ne 'cli') {
5425 my $authuser = $rpcenv->get_user();
5426 $rpcenv->check($authuser, "/storage/$statestorage", ['Datastore.AllocateSpace']);
5431 $vmstate = PVE
::QemuConfig-
>__snapshot_save_vmstate($vmid, $conf, "suspend-$date", $storecfg, $statestorage, 1);
5432 $path = PVE
::Storage
::path
($storecfg, $vmstate);
5433 PVE
::QemuConfig-
>write_config($vmid, $conf);
5435 mon_cmd
($vmid, "stop");
5439 if ($includestate) {
5441 PVE
::Storage
::activate_volumes
($storecfg, [$vmstate]);
5444 mon_cmd
($vmid, "savevm-start", statefile
=> $path);
5446 my $state = mon_cmd
($vmid, "query-savevm");
5447 if (!$state->{status
}) {
5448 die "savevm not active\n";
5449 } elsif ($state->{status
} eq 'active') {
5452 } elsif ($state->{status
} eq 'completed') {
5453 print "State saved, quitting\n";
5455 } elsif ($state->{status
} eq 'failed' && $state->{error
}) {
5456 die "query-savevm failed with error '$state->{error}'\n"
5458 die "query-savevm returned status '$state->{status}'\n";
5464 PVE
::QemuConfig-
>lock_config($vmid, sub {
5465 $conf = PVE
::QemuConfig-
>load_config($vmid);
5467 # cleanup, but leave suspending lock, to indicate something went wrong
5469 mon_cmd
($vmid, "savevm-end");
5470 PVE
::Storage
::deactivate_volumes
($storecfg, [$vmstate]);
5471 PVE
::Storage
::vdisk_free
($storecfg, $vmstate);
5472 delete $conf->@{qw(vmstate runningmachine runningcpu)};
5473 PVE
::QemuConfig-
>write_config($vmid, $conf);
5479 die "lock changed unexpectedly\n"
5480 if !PVE
::QemuConfig-
>has_lock($conf, 'suspending');
5482 mon_cmd
($vmid, "quit");
5483 $conf->{lock} = 'suspended';
5484 PVE
::QemuConfig-
>write_config($vmid, $conf);
5490 my ($vmid, $skiplock, $nocheck) = @_;
5492 PVE
::QemuConfig-
>lock_config($vmid, sub {
5493 my $res = mon_cmd
($vmid, 'query-status');
5494 my $resume_cmd = 'cont';
5496 if ($res->{status
} && $res->{status
} eq 'suspended') {
5497 $resume_cmd = 'system_wakeup';
5502 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5504 PVE
::QemuConfig-
>check_lock($conf)
5505 if !($skiplock || PVE
::QemuConfig-
>has_lock($conf, 'backup'));
5508 mon_cmd
($vmid, $resume_cmd);
5513 my ($vmid, $skiplock, $key) = @_;
5515 PVE
::QemuConfig-
>lock_config($vmid, sub {
5517 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5519 # there is no qmp command, so we use the human monitor command
5520 my $res = PVE
::QemuServer
::Monitor
::hmp_cmd
($vmid, "sendkey $key");
5521 die $res if $res ne '';
5525 # vzdump restore implementaion
5527 sub tar_archive_read_firstfile
{
5528 my $archive = shift;
5530 die "ERROR: file '$archive' does not exist\n" if ! -f
$archive;
5532 # try to detect archive type first
5533 my $pid = open (my $fh, '-|', 'tar', 'tf', $archive) ||
5534 die "unable to open file '$archive'\n";
5535 my $firstfile = <$fh>;
5539 die "ERROR: archive contaions no data\n" if !$firstfile;
5545 sub tar_restore_cleanup
{
5546 my ($storecfg, $statfile) = @_;
5548 print STDERR
"starting cleanup\n";
5550 if (my $fd = IO
::File-
>new($statfile, "r")) {
5551 while (defined(my $line = <$fd>)) {
5552 if ($line =~ m/vzdump:([^\s:]*):(\S+)$/) {
5555 if ($volid =~ m
|^/|) {
5556 unlink $volid || die 'unlink failed\n';
5558 PVE
::Storage
::vdisk_free
($storecfg, $volid);
5560 print STDERR
"temporary volume '$volid' sucessfuly removed\n";
5562 print STDERR
"unable to cleanup '$volid' - $@" if $@;
5564 print STDERR
"unable to parse line in statfile - $line";
5571 sub restore_file_archive
{
5572 my ($archive, $vmid, $user, $opts) = @_;
5574 my $format = $opts->{format
};
5577 if ($archive =~ m/\.tgz$/ || $archive =~ m/\.tar\.gz$/) {
5578 $format = 'tar' if !$format;
5580 } elsif ($archive =~ m/\.tar$/) {
5581 $format = 'tar' if !$format;
5582 } elsif ($archive =~ m/.tar.lzo$/) {
5583 $format = 'tar' if !$format;
5585 } elsif ($archive =~ m/\.vma$/) {
5586 $format = 'vma' if !$format;
5587 } elsif ($archive =~ m/\.vma\.gz$/) {
5588 $format = 'vma' if !$format;
5590 } elsif ($archive =~ m/\.vma\.lzo$/) {
5591 $format = 'vma' if !$format;
5594 $format = 'vma' if !$format; # default
5597 # try to detect archive format
5598 if ($format eq 'tar') {
5599 return restore_tar_archive
($archive, $vmid, $user, $opts);
5601 return restore_vma_archive
($archive, $vmid, $user, $opts, $comp);
5605 # hepler to remove disks that will not be used after restore
5606 my $restore_cleanup_oldconf = sub {
5607 my ($storecfg, $vmid, $oldconf, $virtdev_hash) = @_;
5609 foreach_drive
($oldconf, sub {
5610 my ($ds, $drive) = @_;
5612 return if drive_is_cdrom
($drive, 1);
5614 my $volid = $drive->{file
};
5615 return if !$volid || $volid =~ m
|^/|;
5617 my ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid);
5618 return if !$path || !$owner || ($owner != $vmid);
5620 # Note: only delete disk we want to restore
5621 # other volumes will become unused
5622 if ($virtdev_hash->{$ds}) {
5623 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid); };
5630 # delete vmstate files, after the restore we have no snapshots anymore
5631 foreach my $snapname (keys %{$oldconf->{snapshots
}}) {
5632 my $snap = $oldconf->{snapshots
}->{$snapname};
5633 if ($snap->{vmstate
}) {
5634 eval { PVE
::Storage
::vdisk_free
($storecfg, $snap->{vmstate
}); };
5642 # Helper to parse vzdump backup device hints
5644 # $rpcenv: Environment, used to ckeck storage permissions
5645 # $user: User ID, to check storage permissions
5646 # $storecfg: Storage configuration
5647 # $fh: the file handle for reading the configuration
5648 # $devinfo: should contain device sizes for all backu-up'ed devices
5649 # $options: backup options (pool, default storage)
5651 # Return: $virtdev_hash, updates $devinfo (add devname, virtdev, format, storeid)
5652 my $parse_backup_hints = sub {
5653 my ($rpcenv, $user, $storecfg, $fh, $devinfo, $options) = @_;
5655 my $virtdev_hash = {};
5657 while (defined(my $line = <$fh>)) {
5658 if ($line =~ m/^\#qmdump\#map:(\S+):(\S+):(\S*):(\S*):$/) {
5659 my ($virtdev, $devname, $storeid, $format) = ($1, $2, $3, $4);
5660 die "archive does not contain data for drive '$virtdev'\n"
5661 if !$devinfo->{$devname};
5663 if (defined($options->{storage
})) {
5664 $storeid = $options->{storage
} || 'local';
5665 } elsif (!$storeid) {
5668 $format = 'raw' if !$format;
5669 $devinfo->{$devname}->{devname
} = $devname;
5670 $devinfo->{$devname}->{virtdev
} = $virtdev;
5671 $devinfo->{$devname}->{format
} = $format;
5672 $devinfo->{$devname}->{storeid
} = $storeid;
5674 # check permission on storage
5675 my $pool = $options->{pool
}; # todo: do we need that?
5676 if ($user ne 'root@pam') {
5677 $rpcenv->check($user, "/storage/$storeid", ['Datastore.AllocateSpace']);
5680 $virtdev_hash->{$virtdev} = $devinfo->{$devname};
5681 } elsif ($line =~ m/^((?:ide|sata|scsi)\d+):\s*(.*)\s*$/) {
5683 my $drive = parse_drive
($virtdev, $2);
5684 if (drive_is_cloudinit
($drive)) {
5685 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($drive->{file
});
5686 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
5687 my $format = qemu_img_format
($scfg, $volname); # has 'raw' fallback
5689 $virtdev_hash->{$virtdev} = {
5691 storeid
=> $options->{storage
} // $storeid,
5692 size
=> PVE
::QemuServer
::Cloudinit
::CLOUDINIT_DISK_SIZE
,
5699 return $virtdev_hash;
5702 # Helper to allocate and activate all volumes required for a restore
5704 # $storecfg: Storage configuration
5705 # $virtdev_hash: as returned by parse_backup_hints()
5707 # Returns: { $virtdev => $volid }
5708 my $restore_allocate_devices = sub {
5709 my ($storecfg, $virtdev_hash, $vmid) = @_;
5712 foreach my $virtdev (sort keys %$virtdev_hash) {
5713 my $d = $virtdev_hash->{$virtdev};
5714 my $alloc_size = int(($d->{size
} + 1024 - 1)/1024);
5715 my $storeid = $d->{storeid
};
5716 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
5718 # test if requested format is supported
5719 my ($defFormat, $validFormats) = PVE
::Storage
::storage_default_format
($storecfg, $storeid);
5720 my $supported = grep { $_ eq $d->{format
} } @$validFormats;
5721 $d->{format
} = $defFormat if !$supported;
5724 if ($d->{is_cloudinit
}) {
5725 $name = "vm-$vmid-cloudinit";
5726 $name .= ".$d->{format}" if $d->{format
} ne 'raw';
5729 my $volid = PVE
::Storage
::vdisk_alloc
($storecfg, $storeid, $vmid, $d->{format
}, $name, $alloc_size);
5731 print STDERR
"new volume ID is '$volid'\n";
5732 $d->{volid
} = $volid;
5734 PVE
::Storage
::activate_volumes
($storecfg, [$volid]);
5736 $map->{$virtdev} = $volid;
5742 my $restore_update_config_line = sub {
5743 my ($outfd, $cookie, $vmid, $map, $line, $unique) = @_;
5745 return if $line =~ m/^\#qmdump\#/;
5746 return if $line =~ m/^\#vzdump\#/;
5747 return if $line =~ m/^lock:/;
5748 return if $line =~ m/^unused\d+:/;
5749 return if $line =~ m/^parent:/;
5751 my $dc = PVE
::Cluster
::cfs_read_file
('datacenter.cfg');
5752 if (($line =~ m/^(vlan(\d+)):\s*(\S+)\s*$/)) {
5753 # try to convert old 1.X settings
5754 my ($id, $ind, $ethcfg) = ($1, $2, $3);
5755 foreach my $devconfig (PVE
::Tools
::split_list
($ethcfg)) {
5756 my ($model, $macaddr) = split(/\=/, $devconfig);
5757 $macaddr = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
}) if !$macaddr || $unique;
5760 bridge
=> "vmbr$ind",
5761 macaddr
=> $macaddr,
5763 my $netstr = print_net
($net);
5765 print $outfd "net$cookie->{netcount}: $netstr\n";
5766 $cookie->{netcount
}++;
5768 } elsif (($line =~ m/^(net\d+):\s*(\S+)\s*$/) && $unique) {
5769 my ($id, $netstr) = ($1, $2);
5770 my $net = parse_net
($netstr);
5771 $net->{macaddr
} = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
}) if $net->{macaddr
};
5772 $netstr = print_net
($net);
5773 print $outfd "$id: $netstr\n";
5774 } elsif ($line =~ m/^((ide|scsi|virtio|sata|efidisk)\d+):\s*(\S+)\s*$/) {
5777 my $di = parse_drive
($virtdev, $value);
5778 if (defined($di->{backup
}) && !$di->{backup
}) {
5779 print $outfd "#$line";
5780 } elsif ($map->{$virtdev}) {
5781 delete $di->{format
}; # format can change on restore
5782 $di->{file
} = $map->{$virtdev};
5783 $value = print_drive
($di);
5784 print $outfd "$virtdev: $value\n";
5788 } elsif (($line =~ m/^vmgenid: (.*)/)) {
5790 if ($vmgenid ne '0') {
5791 # always generate a new vmgenid if there was a valid one setup
5792 $vmgenid = generate_uuid
();
5794 print $outfd "vmgenid: $vmgenid\n";
5795 } elsif (($line =~ m/^(smbios1: )(.*)/) && $unique) {
5796 my ($uuid, $uuid_str);
5797 UUID
::generate
($uuid);
5798 UUID
::unparse
($uuid, $uuid_str);
5799 my $smbios1 = parse_smbios1
($2);
5800 $smbios1->{uuid
} = $uuid_str;
5801 print $outfd $1.print_smbios1
($smbios1)."\n";
5807 my $restore_deactivate_volumes = sub {
5808 my ($storecfg, $devinfo) = @_;
5811 foreach my $devname (keys %$devinfo) {
5812 my $volid = $devinfo->{$devname}->{volid
};
5813 push @$vollist, $volid if $volid;
5816 PVE
::Storage
::deactivate_volumes
($storecfg, $vollist);
5819 my $restore_destroy_volumes = sub {
5820 my ($storecfg, $devinfo) = @_;
5822 foreach my $devname (keys %$devinfo) {
5823 my $volid = $devinfo->{$devname}->{volid
};
5826 if ($volid =~ m
|^/|) {
5827 unlink $volid || die 'unlink failed\n';
5829 PVE
::Storage
::vdisk_free
($storecfg, $volid);
5831 print STDERR
"temporary volume '$volid' sucessfuly removed\n";
5833 print STDERR
"unable to cleanup '$volid' - $@" if $@;
5838 my ($cfg, $vmid) = @_;
5840 my $info = PVE
::Storage
::vdisk_list
($cfg, undef, $vmid);
5842 my $volid_hash = {};
5843 foreach my $storeid (keys %$info) {
5844 foreach my $item (@{$info->{$storeid}}) {
5845 next if !($item->{volid
} && $item->{size
});
5846 $item->{path
} = PVE
::Storage
::path
($cfg, $item->{volid
});
5847 $volid_hash->{$item->{volid
}} = $item;
5854 sub update_disk_config
{
5855 my ($vmid, $conf, $volid_hash) = @_;
5858 my $prefix = "VM $vmid:";
5860 # used and unused disks
5861 my $referenced = {};
5863 # Note: it is allowed to define multiple storages with same path (alias), so
5864 # we need to check both 'volid' and real 'path' (two different volid can point
5865 # to the same path).
5867 my $referencedpath = {};
5870 PVE
::QemuConfig-
>foreach_volume($conf, sub {
5871 my ($opt, $drive) = @_;
5873 my $volid = $drive->{file
};
5876 # mark volid as "in-use" for next step
5877 $referenced->{$volid} = 1;
5878 if ($volid_hash->{$volid} &&
5879 (my $path = $volid_hash->{$volid}->{path
})) {
5880 $referencedpath->{$path} = 1;
5883 return if drive_is_cdrom
($drive);
5884 return if !$volid_hash->{$volid};
5886 my ($updated, $old_size, $new_size) = PVE
::QemuServer
::Drive
::update_disksize
($drive, $volid_hash);
5887 if (defined($updated)) {
5889 $conf->{$opt} = print_drive
($updated);
5890 print "$prefix size of disk '$volid' ($opt) updated from $old_size to $new_size\n";
5894 # remove 'unusedX' entry if volume is used
5895 PVE
::QemuConfig-
>foreach_unused_volume($conf, sub {
5896 my ($opt, $drive) = @_;
5898 my $volid = $drive->{file
};
5901 my $path = $volid_hash->{$volid}->{path
} if $volid_hash->{$volid};
5902 if ($referenced->{$volid} || ($path && $referencedpath->{$path})) {
5903 print "$prefix remove entry '$opt', its volume '$volid' is in use\n";
5905 delete $conf->{$opt};
5908 $referenced->{$volid} = 1;
5909 $referencedpath->{$path} = 1 if $path;
5912 foreach my $volid (sort keys %$volid_hash) {
5913 next if $volid =~ m/vm-$vmid-state-/;
5914 next if $referenced->{$volid};
5915 my $path = $volid_hash->{$volid}->{path
};
5916 next if !$path; # just to be sure
5917 next if $referencedpath->{$path};
5919 my $key = PVE
::QemuConfig-
>add_unused_volume($conf, $volid);
5920 print "$prefix add unreferenced volume '$volid' as '$key' to config\n";
5921 $referencedpath->{$path} = 1; # avoid to add more than once (aliases)
5928 my ($vmid, $nolock, $dryrun) = @_;
5930 my $cfg = PVE
::Storage
::config
();
5932 # FIXME: Remove once our RBD plugin can handle CT and VM on a single storage
5933 # see: https://pve.proxmox.com/pipermail/pve-devel/2018-July/032900.html
5934 foreach my $stor (keys %{$cfg->{ids
}}) {
5935 delete($cfg->{ids
}->{$stor}) if ! $cfg->{ids
}->{$stor}->{content
}->{images
};
5938 print "rescan volumes...\n";
5939 my $volid_hash = scan_volids
($cfg, $vmid);
5941 my $updatefn = sub {
5944 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5946 PVE
::QemuConfig-
>check_lock($conf);
5949 foreach my $volid (keys %$volid_hash) {
5950 my $info = $volid_hash->{$volid};
5951 $vm_volids->{$volid} = $info if $info->{vmid
} && $info->{vmid
} == $vmid;
5954 my $changes = update_disk_config
($vmid, $conf, $vm_volids);
5956 PVE
::QemuConfig-
>write_config($vmid, $conf) if $changes && !$dryrun;
5959 if (defined($vmid)) {
5963 PVE
::QemuConfig-
>lock_config($vmid, $updatefn, $vmid);
5966 my $vmlist = config_list
();
5967 foreach my $vmid (keys %$vmlist) {
5971 PVE
::QemuConfig-
>lock_config($vmid, $updatefn, $vmid);
5977 sub restore_proxmox_backup_archive
{
5978 my ($archive, $vmid, $user, $options) = @_;
5980 my $storecfg = PVE
::Storage
::config
();
5982 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($archive);
5983 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
5985 my $server = $scfg->{server
};
5986 my $datastore = $scfg->{datastore
};
5987 my $username = $scfg->{username
} // 'root@pam';
5988 my $fingerprint = $scfg->{fingerprint
};
5990 my $repo = "$username\@$server:$datastore";
5991 my $password = PVE
::Storage
::PBSPlugin
::pbs_get_password
($scfg, $storeid);
5992 local $ENV{PBS_PASSWORD
} = $password;
5993 local $ENV{PBS_FINGERPRINT
} = $fingerprint if defined($fingerprint);
5995 my ($vtype, $pbs_backup_name, undef, undef, undef, undef, $format) =
5996 PVE
::Storage
::parse_volname
($storecfg, $archive);
5998 die "got unexpected vtype '$vtype'\n" if $vtype ne 'backup';
6000 die "got unexpected backup format '$format'\n" if $format ne 'pbs-vm';
6002 my $tmpdir = "/var/tmp/vzdumptmp$$";
6006 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6007 my $tmpfn = "$conffile.$$.tmp";
6008 # disable interrupts (always do cleanups)
6012 local $SIG{HUP
} = sub { print STDERR
"got interrupt - ignored\n"; };
6014 # Note: $oldconf is undef if VM does not exists
6015 my $cfs_path = PVE
::QemuConfig-
>cfs_config_path($vmid);
6016 my $oldconf = PVE
::Cluster
::cfs_read_file
($cfs_path);
6018 my $rpcenv = PVE
::RPCEnvironment
::get
();
6027 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6029 my $cfgfn = "$tmpdir/qemu-server.conf";
6030 my $firewall_config_fn = "$tmpdir/fw.conf";
6031 my $index_fn = "$tmpdir/index.json";
6033 my $cmd = "restore";
6035 my $param = [$pbs_backup_name, "index.json", $index_fn];
6036 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6037 my $index = PVE
::Tools
::file_get_contents
($index_fn);
6038 $index = decode_json
($index);
6040 # print Dumper($index);
6041 foreach my $info (@{$index->{files
}}) {
6042 if ($info->{filename
} =~ m/^(drive-\S+).img.fidx$/) {
6044 if ($info->{size
} =~ m/^(\d+)$/) { # untaint size
6045 $devinfo->{$devname}->{size
} = $1;
6047 die "unable to parse file size in 'index.json' - got '$info->{size}'\n";
6052 my $is_qemu_server_backup = scalar(grep { $_->{filename
} eq 'qemu-server.conf.blob' } @{$index->{files
}});
6053 if (!$is_qemu_server_backup) {
6054 die "backup does not look like a qemu-server backup (missing 'qemu-server.conf' file)\n";
6056 my $has_firewall_config = scalar(grep { $_->{filename
} eq 'fw.conf.blob' } @{$index->{files
}});
6058 $param = [$pbs_backup_name, "qemu-server.conf", $cfgfn];
6059 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6061 if ($has_firewall_config) {
6062 $param = [$pbs_backup_name, "fw.conf", $firewall_config_fn];
6063 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6065 my $pve_firewall_dir = '/etc/pve/firewall';
6066 mkdir $pve_firewall_dir; # make sure the dir exists
6067 PVE
::Tools
::file_copy
($firewall_config_fn, "${pve_firewall_dir}/$vmid.fw");
6070 my $fh = IO
::File-
>new($cfgfn, "r") ||
6071 "unable to read qemu-server.conf - $!\n";
6073 my $virtdev_hash = $parse_backup_hints->($rpcenv, $user, $storecfg, $fh, $devinfo, $options);
6075 # fixme: rate limit?
6077 # create empty/temp config
6078 PVE
::Tools
::file_set_contents
($conffile, "memory: 128\nlock: create");
6080 $restore_cleanup_oldconf->($storecfg, $vmid, $oldconf, $virtdev_hash) if $oldconf;
6083 my $map = $restore_allocate_devices->($storecfg, $virtdev_hash, $vmid);
6085 foreach my $virtdev (sort keys %$virtdev_hash) {
6086 my $d = $virtdev_hash->{$virtdev};
6087 next if $d->{is_cloudinit
}; # no need to restore cloudinit
6089 my $volid = $d->{volid
};
6091 my $path = PVE
::Storage
::path
($storecfg, $volid);
6093 my $pbs_restore_cmd = [
6094 '/usr/bin/pbs-restore',
6095 '--repository', $repo,
6097 "$d->{devname}.img.fidx",
6102 if (PVE
::Storage
::volume_has_feature
($storecfg, 'sparseinit', $volid)) {
6103 push @$pbs_restore_cmd, '--skip-zero';
6106 my $dbg_cmdstring = PVE
::Tools
::cmd2string
($pbs_restore_cmd);
6107 print "restore proxmox backup image: $dbg_cmdstring\n";
6108 run_command
($pbs_restore_cmd);
6111 $fh->seek(0, 0) || die "seek failed - $!\n";
6113 my $outfd = new IO
::File
($tmpfn, "w") ||
6114 die "unable to write config for VM $vmid\n";
6116 my $cookie = { netcount
=> 0 };
6117 while (defined(my $line = <$fh>)) {
6118 $restore_update_config_line->($outfd, $cookie, $vmid, $map, $line, $options->{unique
});
6126 $restore_deactivate_volumes->($storecfg, $devinfo);
6132 $restore_destroy_volumes->($storecfg, $devinfo);
6136 rename($tmpfn, $conffile) ||
6137 die "unable to commit configuration file '$conffile'\n";
6139 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6141 eval { rescan
($vmid, 1); };
6145 sub restore_vma_archive
{
6146 my ($archive, $vmid, $user, $opts, $comp) = @_;
6148 my $readfrom = $archive;
6150 my $cfg = PVE
::Storage
::config
();
6152 my $bwlimit = $opts->{bwlimit
};
6154 my $dbg_cmdstring = '';
6155 my $add_pipe = sub {
6157 push @$commands, $cmd;
6158 $dbg_cmdstring .= ' | ' if length($dbg_cmdstring);
6159 $dbg_cmdstring .= PVE
::Tools
::cmd2string
($cmd);
6164 if ($archive eq '-') {
6167 # If we use a backup from a PVE defined storage we also consider that
6168 # storage's rate limit:
6169 my (undef, $volid) = PVE
::Storage
::path_to_volume_id
($cfg, $archive);
6170 if (defined($volid)) {
6171 my ($sid, undef) = PVE
::Storage
::parse_volume_id
($volid);
6172 my $readlimit = PVE
::Storage
::get_bandwidth_limit
('restore', [$sid], $bwlimit);
6174 print STDERR
"applying read rate limit: $readlimit\n";
6175 my $cstream = ['cstream', '-t', $readlimit*1024, '--', $readfrom];
6176 $add_pipe->($cstream);
6183 if ($comp eq 'gzip') {
6184 $cmd = ['zcat', $readfrom];
6185 } elsif ($comp eq 'lzop') {
6186 $cmd = ['lzop', '-d', '-c', $readfrom];
6188 die "unknown compression method '$comp'\n";
6193 my $tmpdir = "/var/tmp/vzdumptmp$$";
6196 # disable interrupts (always do cleanups)
6200 local $SIG{HUP
} = sub { warn "got interrupt - ignored\n"; };
6202 my $mapfifo = "/var/tmp/vzdumptmp$$.fifo";
6203 POSIX
::mkfifo
($mapfifo, 0600);
6206 my $openfifo = sub {
6207 open($fifofh, '>', $mapfifo) || die $!;
6210 $add_pipe->(['vma', 'extract', '-v', '-r', $mapfifo, $readfrom, $tmpdir]);
6217 my $rpcenv = PVE
::RPCEnvironment
::get
();
6219 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6220 my $tmpfn = "$conffile.$$.tmp";
6222 # Note: $oldconf is undef if VM does not exist
6223 my $cfs_path = PVE
::QemuConfig-
>cfs_config_path($vmid);
6224 my $oldconf = PVE
::Cluster
::cfs_read_file
($cfs_path);
6228 my $print_devmap = sub {
6229 my $cfgfn = "$tmpdir/qemu-server.conf";
6231 # we can read the config - that is already extracted
6232 my $fh = IO
::File-
>new($cfgfn, "r") ||
6233 "unable to read qemu-server.conf - $!\n";
6235 my $fwcfgfn = "$tmpdir/qemu-server.fw";
6237 my $pve_firewall_dir = '/etc/pve/firewall';
6238 mkdir $pve_firewall_dir; # make sure the dir exists
6239 PVE
::Tools
::file_copy
($fwcfgfn, "${pve_firewall_dir}/$vmid.fw");
6242 my $virtdev_hash = $parse_backup_hints->($rpcenv, $user, $cfg, $fh, $devinfo, $opts);
6244 foreach my $key (keys %storage_limits) {
6245 my $limit = PVE
::Storage
::get_bandwidth_limit
('restore', [$key], $bwlimit);
6247 print STDERR
"rate limit for storage $key: $limit KiB/s\n";
6248 $storage_limits{$key} = $limit * 1024;
6251 foreach my $devname (keys %$devinfo) {
6252 die "found no device mapping information for device '$devname'\n"
6253 if !$devinfo->{$devname}->{virtdev
};
6256 # create empty/temp config
6258 PVE
::Tools
::file_set_contents
($conffile, "memory: 128\n");
6259 $restore_cleanup_oldconf->($cfg, $vmid, $oldconf, $virtdev_hash);
6263 my $map = $restore_allocate_devices->($cfg, $virtdev_hash, $vmid);
6265 # print restore information to $fifofh
6266 foreach my $virtdev (sort keys %$virtdev_hash) {
6267 my $d = $virtdev_hash->{$virtdev};
6268 next if $d->{is_cloudinit
}; # no need to restore cloudinit
6270 my $storeid = $d->{storeid
};
6271 my $volid = $d->{volid
};
6274 if (my $limit = $storage_limits{$storeid}) {
6275 $map_opts .= "throttling.bps=$limit:throttling.group=$storeid:";
6278 my $write_zeros = 1;
6279 if (PVE
::Storage
::volume_has_feature
($cfg, 'sparseinit', $volid)) {
6283 my $path = PVE
::Storage
::path
($cfg, $volid);
6285 print $fifofh "${map_opts}format=$d->{format}:${write_zeros}:$d->{devname}=$path\n";
6287 print "map '$d->{devname}' to '$path' (write zeros = ${write_zeros})\n";
6290 $fh->seek(0, 0) || die "seek failed - $!\n";
6292 my $outfd = new IO
::File
($tmpfn, "w") ||
6293 die "unable to write config for VM $vmid\n";
6295 my $cookie = { netcount
=> 0 };
6296 while (defined(my $line = <$fh>)) {
6297 $restore_update_config_line->($outfd, $cookie, $vmid, $map, $line, $opts->{unique
});
6310 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6311 local $SIG{ALRM
} = sub { die "got timeout\n"; };
6313 $oldtimeout = alarm($timeout);
6320 if ($line =~ m/^DEV:\sdev_id=(\d+)\ssize:\s(\d+)\sdevname:\s(\S+)$/) {
6321 my ($dev_id, $size, $devname) = ($1, $2, $3);
6322 $devinfo->{$devname} = { size
=> $size, dev_id
=> $dev_id };
6323 } elsif ($line =~ m/^CTIME: /) {
6324 # we correctly received the vma config, so we can disable
6325 # the timeout now for disk allocation (set to 10 minutes, so
6326 # that we always timeout if something goes wrong)
6329 print $fifofh "done\n";
6330 my $tmp = $oldtimeout || 0;
6331 $oldtimeout = undef;
6337 print "restore vma archive: $dbg_cmdstring\n";
6338 run_command
($commands, input
=> $input, outfunc
=> $parser, afterfork
=> $openfifo);
6342 alarm($oldtimeout) if $oldtimeout;
6344 $restore_deactivate_volumes->($cfg, $devinfo);
6351 $restore_destroy_volumes->($cfg, $devinfo);
6355 rename($tmpfn, $conffile) ||
6356 die "unable to commit configuration file '$conffile'\n";
6358 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6360 eval { rescan
($vmid, 1); };
6364 sub restore_tar_archive
{
6365 my ($archive, $vmid, $user, $opts) = @_;
6367 if ($archive ne '-') {
6368 my $firstfile = tar_archive_read_firstfile
($archive);
6369 die "ERROR: file '$archive' dos not lock like a QemuServer vzdump backup\n"
6370 if $firstfile ne 'qemu-server.conf';
6373 my $storecfg = PVE
::Storage
::config
();
6375 # avoid zombie disks when restoring over an existing VM -> cleanup first
6376 # pass keep_empty_config=1 to keep the config (thus VMID) reserved for us
6377 # skiplock=1 because qmrestore has set the 'create' lock itself already
6378 my $vmcfgfn = PVE
::QemuConfig-
>config_file($vmid);
6379 destroy_vm
($storecfg, $vmid, 1, { lock => 'restore' }) if -f
$vmcfgfn;
6381 my $tocmd = "/usr/lib/qemu-server/qmextract";
6383 $tocmd .= " --storage " . PVE
::Tools
::shellquote
($opts->{storage
}) if $opts->{storage
};
6384 $tocmd .= " --pool " . PVE
::Tools
::shellquote
($opts->{pool
}) if $opts->{pool
};
6385 $tocmd .= ' --prealloc' if $opts->{prealloc
};
6386 $tocmd .= ' --info' if $opts->{info
};
6388 # tar option "xf" does not autodetect compression when read from STDIN,
6389 # so we pipe to zcat
6390 my $cmd = "zcat -f|tar xf " . PVE
::Tools
::shellquote
($archive) . " " .
6391 PVE
::Tools
::shellquote
("--to-command=$tocmd");
6393 my $tmpdir = "/var/tmp/vzdumptmp$$";
6396 local $ENV{VZDUMP_TMPDIR
} = $tmpdir;
6397 local $ENV{VZDUMP_VMID
} = $vmid;
6398 local $ENV{VZDUMP_USER
} = $user;
6400 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6401 my $tmpfn = "$conffile.$$.tmp";
6403 # disable interrupts (always do cleanups)
6407 local $SIG{HUP
} = sub { print STDERR
"got interrupt - ignored\n"; };
6415 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6417 if ($archive eq '-') {
6418 print "extracting archive from STDIN\n";
6419 run_command
($cmd, input
=> "<&STDIN");
6421 print "extracting archive '$archive'\n";
6425 return if $opts->{info
};
6429 my $statfile = "$tmpdir/qmrestore.stat";
6430 if (my $fd = IO
::File-
>new($statfile, "r")) {
6431 while (defined (my $line = <$fd>)) {
6432 if ($line =~ m/vzdump:([^\s:]*):(\S+)$/) {
6433 $map->{$1} = $2 if $1;
6435 print STDERR
"unable to parse line in statfile - $line\n";
6441 my $confsrc = "$tmpdir/qemu-server.conf";
6443 my $srcfd = new IO
::File
($confsrc, "r") ||
6444 die "unable to open file '$confsrc'\n";
6446 my $outfd = new IO
::File
($tmpfn, "w") ||
6447 die "unable to write config for VM $vmid\n";
6449 my $cookie = { netcount
=> 0 };
6450 while (defined (my $line = <$srcfd>)) {
6451 $restore_update_config_line->($outfd, $cookie, $vmid, $map, $line, $opts->{unique
});
6459 tar_restore_cleanup
($storecfg, "$tmpdir/qmrestore.stat") if !$opts->{info
};
6465 rename $tmpfn, $conffile ||
6466 die "unable to commit configuration file '$conffile'\n";
6468 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6470 eval { rescan
($vmid, 1); };
6474 sub foreach_storage_used_by_vm
{
6475 my ($conf, $func) = @_;
6479 foreach_drive
($conf, sub {
6480 my ($ds, $drive) = @_;
6481 return if drive_is_cdrom
($drive);
6483 my $volid = $drive->{file
};
6485 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
6486 $sidhash->{$sid} = $sid if $sid;
6489 foreach my $sid (sort keys %$sidhash) {
6494 my $qemu_snap_storage = {
6497 sub do_snapshots_with_qemu
{
6498 my ($storecfg, $volid) = @_;
6500 my $storage_name = PVE
::Storage
::parse_volume_id
($volid);
6501 my $scfg = $storecfg->{ids
}->{$storage_name};
6503 if ($qemu_snap_storage->{$scfg->{type
}} && !$scfg->{krbd
}){
6507 if ($volid =~ m/\.(qcow2|qed)$/){
6514 sub qga_check_running
{
6515 my ($vmid, $nowarn) = @_;
6517 eval { mon_cmd
($vmid, "guest-ping", timeout
=> 3); };
6519 warn "Qemu Guest Agent is not running - $@" if !$nowarn;
6525 sub template_create
{
6526 my ($vmid, $conf, $disk) = @_;
6528 my $storecfg = PVE
::Storage
::config
();
6530 foreach_drive
($conf, sub {
6531 my ($ds, $drive) = @_;
6533 return if drive_is_cdrom
($drive);
6534 return if $disk && $ds ne $disk;
6536 my $volid = $drive->{file
};
6537 return if !PVE
::Storage
::volume_has_feature
($storecfg, 'template', $volid);
6539 my $voliddst = PVE
::Storage
::vdisk_create_base
($storecfg, $volid);
6540 $drive->{file
} = $voliddst;
6541 $conf->{$ds} = print_drive
($drive);
6542 PVE
::QemuConfig-
>write_config($vmid, $conf);
6546 sub convert_iscsi_path
{
6549 if ($path =~ m
|^iscsi
://([^/]+)/([^/]+)/(.+)$|) {
6554 my $initiator_name = get_initiator_name
();
6556 return "file.driver=iscsi,file.transport=tcp,file.initiator-name=$initiator_name,".
6557 "file.portal=$portal,file.target=$target,file.lun=$lun,driver=raw";
6560 die "cannot convert iscsi path '$path', unkown format\n";
6563 sub qemu_img_convert
{
6564 my ($src_volid, $dst_volid, $size, $snapname, $is_zero_initialized) = @_;
6566 my $storecfg = PVE
::Storage
::config
();
6567 my ($src_storeid, $src_volname) = PVE
::Storage
::parse_volume_id
($src_volid, 1);
6568 my ($dst_storeid, $dst_volname) = PVE
::Storage
::parse_volume_id
($dst_volid, 1);
6570 die "destination '$dst_volid' is not a valid volid form qemu-img convert\n" if !$dst_storeid;
6574 my $src_is_iscsi = 0;
6578 PVE
::Storage
::activate_volumes
($storecfg, [$src_volid], $snapname);
6579 my $src_scfg = PVE
::Storage
::storage_config
($storecfg, $src_storeid);
6580 $src_format = qemu_img_format
($src_scfg, $src_volname);
6581 $src_path = PVE
::Storage
::path
($storecfg, $src_volid, $snapname);
6582 $src_is_iscsi = ($src_path =~ m
|^iscsi
://|);
6583 $cachemode = 'none' if $src_scfg->{type
} eq 'zfspool';
6584 } elsif (-f
$src_volid) {
6585 $src_path = $src_volid;
6586 if ($src_path =~ m/\.($PVE::QemuServer::Drive::QEMU_FORMAT_RE)$/) {
6591 die "source '$src_volid' is not a valid volid nor path for qemu-img convert\n" if !$src_path;
6593 my $dst_scfg = PVE
::Storage
::storage_config
($storecfg, $dst_storeid);
6594 my $dst_format = qemu_img_format
($dst_scfg, $dst_volname);
6595 my $dst_path = PVE
::Storage
::path
($storecfg, $dst_volid);
6596 my $dst_is_iscsi = ($dst_path =~ m
|^iscsi
://|);
6599 push @$cmd, '/usr/bin/qemu-img', 'convert', '-p', '-n';
6600 push @$cmd, '-l', "snapshot.name=$snapname"
6601 if $snapname && $src_format && $src_format eq "qcow2";
6602 push @$cmd, '-t', 'none' if $dst_scfg->{type
} eq 'zfspool';
6603 push @$cmd, '-T', $cachemode if defined($cachemode);
6605 if ($src_is_iscsi) {
6606 push @$cmd, '--image-opts';
6607 $src_path = convert_iscsi_path
($src_path);
6608 } elsif ($src_format) {
6609 push @$cmd, '-f', $src_format;
6612 if ($dst_is_iscsi) {
6613 push @$cmd, '--target-image-opts';
6614 $dst_path = convert_iscsi_path
($dst_path);
6616 push @$cmd, '-O', $dst_format;
6619 push @$cmd, $src_path;
6621 if (!$dst_is_iscsi && $is_zero_initialized) {
6622 push @$cmd, "zeroinit:$dst_path";
6624 push @$cmd, $dst_path;
6629 if($line =~ m/\((\S+)\/100\
%\)/){
6631 my $transferred = int($size * $percent / 100);
6632 my $remaining = $size - $transferred;
6634 print "transferred: $transferred bytes remaining: $remaining bytes total: $size bytes progression: $percent %\n";
6639 eval { run_command
($cmd, timeout
=> undef, outfunc
=> $parser); };
6641 die "copy failed: $err" if $err;
6644 sub qemu_img_format
{
6645 my ($scfg, $volname) = @_;
6647 if ($scfg->{path
} && $volname =~ m/\.($PVE::QemuServer::Drive::QEMU_FORMAT_RE)$/) {
6654 sub qemu_drive_mirror
{
6655 my ($vmid, $drive, $dst_volid, $vmiddst, $is_zero_initialized, $jobs, $completion, $qga, $bwlimit, $src_bitmap) = @_;
6657 $jobs = {} if !$jobs;
6661 $jobs->{"drive-$drive"} = {};
6663 if ($dst_volid =~ /^nbd:/) {
6664 $qemu_target = $dst_volid;
6667 my $storecfg = PVE
::Storage
::config
();
6668 my ($dst_storeid, $dst_volname) = PVE
::Storage
::parse_volume_id
($dst_volid);
6670 my $dst_scfg = PVE
::Storage
::storage_config
($storecfg, $dst_storeid);
6672 $format = qemu_img_format
($dst_scfg, $dst_volname);
6674 my $dst_path = PVE
::Storage
::path
($storecfg, $dst_volid);
6676 $qemu_target = $is_zero_initialized ?
"zeroinit:$dst_path" : $dst_path;
6679 my $opts = { timeout
=> 10, device
=> "drive-$drive", mode
=> "existing", sync
=> "full", target
=> $qemu_target };
6680 $opts->{format
} = $format if $format;
6682 if (defined($src_bitmap)) {
6683 $opts->{sync
} = 'incremental';
6684 $opts->{bitmap
} = $src_bitmap;
6685 print "drive mirror re-using dirty bitmap '$src_bitmap'\n";
6688 if (defined($bwlimit)) {
6689 $opts->{speed
} = $bwlimit * 1024;
6690 print "drive mirror is starting for drive-$drive with bandwidth limit: ${bwlimit} KB/s\n";
6692 print "drive mirror is starting for drive-$drive\n";
6695 # if a job already runs for this device we get an error, catch it for cleanup
6696 eval { mon_cmd
($vmid, "drive-mirror", %$opts); };
6698 eval { PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs) };
6700 die "mirroring error: $err\n";
6703 qemu_drive_mirror_monitor
($vmid, $vmiddst, $jobs, $completion, $qga);
6706 # $completion can be either
6707 # 'complete': wait until all jobs are ready, block-job-complete them (default)
6708 # 'cancel': wait until all jobs are ready, block-job-cancel them
6709 # 'skip': wait until all jobs are ready, return with block jobs in ready state
6710 sub qemu_drive_mirror_monitor
{
6711 my ($vmid, $vmiddst, $jobs, $completion, $qga) = @_;
6713 $completion //= 'complete';
6716 my $err_complete = 0;
6719 die "storage migration timed out\n" if $err_complete > 300;
6721 my $stats = mon_cmd
($vmid, "query-block-jobs");
6723 my $running_mirror_jobs = {};
6724 foreach my $stat (@$stats) {
6725 next if $stat->{type
} ne 'mirror';
6726 $running_mirror_jobs->{$stat->{device
}} = $stat;
6729 my $readycounter = 0;
6731 foreach my $job (keys %$jobs) {
6733 if(defined($jobs->{$job}->{complete
}) && !defined($running_mirror_jobs->{$job})) {
6734 print "$job : finished\n";
6735 delete $jobs->{$job};
6739 die "$job: mirroring has been cancelled\n" if !defined($running_mirror_jobs->{$job});
6741 my $busy = $running_mirror_jobs->{$job}->{busy
};
6742 my $ready = $running_mirror_jobs->{$job}->{ready
};
6743 if (my $total = $running_mirror_jobs->{$job}->{len
}) {
6744 my $transferred = $running_mirror_jobs->{$job}->{offset
} || 0;
6745 my $remaining = $total - $transferred;
6746 my $percent = sprintf "%.2f", ($transferred * 100 / $total);
6748 print "$job: transferred: $transferred bytes remaining: $remaining bytes total: $total bytes progression: $percent % busy: $busy ready: $ready \n";
6751 $readycounter++ if $running_mirror_jobs->{$job}->{ready
};
6754 last if scalar(keys %$jobs) == 0;
6756 if ($readycounter == scalar(keys %$jobs)) {
6757 print "all mirroring jobs are ready \n";
6758 last if $completion eq 'skip'; #do the complete later
6760 if ($vmiddst && $vmiddst != $vmid) {
6761 my $agent_running = $qga && qga_check_running
($vmid);
6762 if ($agent_running) {
6763 print "freeze filesystem\n";
6764 eval { mon_cmd
($vmid, "guest-fsfreeze-freeze"); };
6766 print "suspend vm\n";
6767 eval { PVE
::QemuServer
::vm_suspend
($vmid, 1); };
6770 # if we clone a disk for a new target vm, we don't switch the disk
6771 PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs);
6773 if ($agent_running) {
6774 print "unfreeze filesystem\n";
6775 eval { mon_cmd
($vmid, "guest-fsfreeze-thaw"); };
6777 print "resume vm\n";
6778 eval { PVE
::QemuServer
::vm_resume
($vmid, 1, 1); };
6784 foreach my $job (keys %$jobs) {
6785 # try to switch the disk if source and destination are on the same guest
6786 print "$job: Completing block job...\n";
6789 if ($completion eq 'complete') {
6790 $op = 'block-job-complete';
6791 } elsif ($completion eq 'cancel') {
6792 $op = 'block-job-cancel';
6794 die "invalid completion value: $completion\n";
6796 eval { mon_cmd
($vmid, $op, device
=> $job) };
6797 if ($@ =~ m/cannot be completed/) {
6798 print "$job: Block job cannot be completed, try again.\n";
6801 print "$job: Completed successfully.\n";
6802 $jobs->{$job}->{complete
} = 1;
6813 eval { PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs) };
6814 die "mirroring error: $err";
6819 sub qemu_blockjobs_cancel
{
6820 my ($vmid, $jobs) = @_;
6822 foreach my $job (keys %$jobs) {
6823 print "$job: Cancelling block job\n";
6824 eval { mon_cmd
($vmid, "block-job-cancel", device
=> $job); };
6825 $jobs->{$job}->{cancel
} = 1;
6829 my $stats = mon_cmd
($vmid, "query-block-jobs");
6831 my $running_jobs = {};
6832 foreach my $stat (@$stats) {
6833 $running_jobs->{$stat->{device
}} = $stat;
6836 foreach my $job (keys %$jobs) {
6838 if (defined($jobs->{$job}->{cancel
}) && !defined($running_jobs->{$job})) {
6839 print "$job: Done.\n";
6840 delete $jobs->{$job};
6844 last if scalar(keys %$jobs) == 0;
6851 my ($storecfg, $vmid, $running, $drivename, $drive, $snapname,
6852 $newvmid, $storage, $format, $full, $newvollist, $jobs, $completion, $qga, $bwlimit, $conf) = @_;
6857 print "create linked clone of drive $drivename ($drive->{file})\n";
6858 $newvolid = PVE
::Storage
::vdisk_clone
($storecfg, $drive->{file
}, $newvmid, $snapname);
6859 push @$newvollist, $newvolid;
6862 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($drive->{file
});
6863 $storeid = $storage if $storage;
6865 my $dst_format = resolve_dst_disk_format
($storecfg, $storeid, $volname, $format);
6866 my ($size) = PVE
::Storage
::volume_size_info
($storecfg, $drive->{file
}, 3);
6868 print "create full clone of drive $drivename ($drive->{file})\n";
6870 if (drive_is_cloudinit
($drive)) {
6871 $name = "vm-$newvmid-cloudinit";
6872 $name .= ".$dst_format" if $dst_format ne 'raw';
6874 $size = PVE
::QemuServer
::Cloudinit
::CLOUDINIT_DISK_SIZE
;
6875 } elsif ($drivename eq 'efidisk0') {
6876 $size = get_efivars_size
($conf);
6878 $newvolid = PVE
::Storage
::vdisk_alloc
($storecfg, $storeid, $newvmid, $dst_format, $name, ($size/1024));
6879 push @$newvollist, $newvolid;
6881 PVE
::Storage
::activate_volumes
($storecfg, [$newvolid]);
6883 if (drive_is_cloudinit
($drive)) {
6887 my $sparseinit = PVE
::Storage
::volume_has_feature
($storecfg, 'sparseinit', $newvolid);
6888 if (!$running || $snapname) {
6889 # TODO: handle bwlimits
6890 if ($drivename eq 'efidisk0') {
6891 # the relevant data on the efidisk may be smaller than the source
6892 # e.g. on RBD/ZFS, so we use dd to copy only the amount
6893 # that is given by the OVMF_VARS.fd
6894 my $src_path = PVE
::Storage
::path
($storecfg, $drive->{file
});
6895 my $dst_path = PVE
::Storage
::path
($storecfg, $newvolid);
6896 run_command
(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=1", "count=$size", "if=$src_path", "of=$dst_path"]);
6898 qemu_img_convert
($drive->{file
}, $newvolid, $size, $snapname, $sparseinit);
6902 my $kvmver = get_running_qemu_version
($vmid);
6903 if (!min_version
($kvmver, 2, 7)) {
6904 die "drive-mirror with iothread requires qemu version 2.7 or higher\n"
6905 if $drive->{iothread
};
6908 qemu_drive_mirror
($vmid, $drivename, $newvolid, $newvmid, $sparseinit, $jobs, $completion, $qga, $bwlimit);
6913 my ($size) = PVE
::Storage
::volume_size_info
($storecfg, $newvolid, 3);
6916 $disk->{format
} = undef;
6917 $disk->{file
} = $newvolid;
6918 $disk->{size
} = $size;
6923 sub get_running_qemu_version
{
6925 my $res = mon_cmd
($vmid, "query-version");
6926 return "$res->{qemu}->{major}.$res->{qemu}->{minor}";
6929 sub qemu_use_old_bios_files
{
6930 my ($machine_type) = @_;
6932 return if !$machine_type;
6934 my $use_old_bios_files = undef;
6936 if ($machine_type =~ m/^(\S+)\.pxe$/) {
6938 $use_old_bios_files = 1;
6940 my $version = PVE
::QemuServer
::Machine
::extract_version
($machine_type, kvm_user_version
());
6941 # Note: kvm version < 2.4 use non-efi pxe files, and have problems when we
6942 # load new efi bios files on migration. So this hack is required to allow
6943 # live migration from qemu-2.2 to qemu-2.4, which is sometimes used when
6944 # updrading from proxmox-ve-3.X to proxmox-ve 4.0
6945 $use_old_bios_files = !min_version
($version, 2, 4);
6948 return ($use_old_bios_files, $machine_type);
6951 sub get_efivars_size
{
6953 my $arch = get_vm_arch
($conf);
6954 my (undef, $ovmf_vars) = get_ovmf_files
($arch);
6955 die "uefi vars image '$ovmf_vars' not found\n" if ! -f
$ovmf_vars;
6956 return -s
$ovmf_vars;
6959 sub update_efidisk_size
{
6962 return if !defined($conf->{efidisk0
});
6964 my $disk = PVE
::QemuServer
::parse_drive
('efidisk0', $conf->{efidisk0
});
6965 $disk->{size
} = get_efivars_size
($conf);
6966 $conf->{efidisk0
} = print_drive
($disk);
6971 sub create_efidisk
($$$$$) {
6972 my ($storecfg, $storeid, $vmid, $fmt, $arch) = @_;
6974 my (undef, $ovmf_vars) = get_ovmf_files
($arch);
6975 die "EFI vars default image not found\n" if ! -f
$ovmf_vars;
6977 my $vars_size_b = -s
$ovmf_vars;
6978 my $vars_size = PVE
::Tools
::convert_size
($vars_size_b, 'b' => 'kb');
6979 my $volid = PVE
::Storage
::vdisk_alloc
($storecfg, $storeid, $vmid, $fmt, undef, $vars_size);
6980 PVE
::Storage
::activate_volumes
($storecfg, [$volid]);
6982 qemu_img_convert
($ovmf_vars, $volid, $vars_size_b, undef, 0);
6983 my ($size) = PVE
::Storage
::volume_size_info
($storecfg, $volid, 3);
6985 return ($volid, $size/1024);
6988 sub vm_iothreads_list
{
6991 my $res = mon_cmd
($vmid, 'query-iothreads');
6994 foreach my $iothread (@$res) {
6995 $iothreads->{ $iothread->{id
} } = $iothread->{"thread-id"};
7002 my ($conf, $drive) = @_;
7006 if (!$conf->{scsihw
} || ($conf->{scsihw
} =~ m/^lsi/)) {
7008 } elsif ($conf->{scsihw
} && ($conf->{scsihw
} eq 'virtio-scsi-single')) {
7014 my $controller = int($drive->{index} / $maxdev);
7015 my $controller_prefix = ($conf->{scsihw
} && $conf->{scsihw
} eq 'virtio-scsi-single') ?
"virtioscsi" : "scsihw";
7017 return ($maxdev, $controller, $controller_prefix);
7020 sub windows_version
{
7023 return 0 if !$ostype;
7027 if($ostype eq 'wxp' || $ostype eq 'w2k3' || $ostype eq 'w2k') {
7029 } elsif($ostype eq 'w2k8' || $ostype eq 'wvista') {
7031 } elsif ($ostype =~ m/^win(\d+)$/) {
7038 sub resolve_dst_disk_format
{
7039 my ($storecfg, $storeid, $src_volname, $format) = @_;
7040 my ($defFormat, $validFormats) = PVE
::Storage
::storage_default_format
($storecfg, $storeid);
7043 # if no target format is specified, use the source disk format as hint
7045 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
7046 $format = qemu_img_format
($scfg, $src_volname);
7052 # test if requested format is supported - else use default
7053 my $supported = grep { $_ eq $format } @$validFormats;
7054 $format = $defFormat if !$supported;
7058 # NOTE: if this logic changes, please update docs & possibly gui logic
7059 sub find_vmstate_storage
{
7060 my ($conf, $storecfg) = @_;
7062 # first, return storage from conf if set
7063 return $conf->{vmstatestorage
} if $conf->{vmstatestorage
};
7065 my ($target, $shared, $local);
7067 foreach_storage_used_by_vm
($conf, sub {
7069 my $scfg = PVE
::Storage
::storage_config
($storecfg, $sid);
7070 my $dst = $scfg->{shared
} ? \
$shared : \
$local;
7071 $$dst = $sid if !$$dst || $scfg->{path
}; # prefer file based storage
7074 # second, use shared storage where VM has at least one disk
7075 # third, use local storage where VM has at least one disk
7076 # fall back to local storage
7077 $target = $shared // $local // 'local';
7083 my ($uuid, $uuid_str);
7084 UUID
::generate
($uuid);
7085 UUID
::unparse
($uuid, $uuid_str);
7089 sub generate_smbios1_uuid
{
7090 return "uuid=".generate_uuid
();
7096 mon_cmd
($vmid, 'nbd-server-stop');
7099 sub create_reboot_request
{
7101 open(my $fh, '>', "/run/qemu-server/$vmid.reboot")
7102 or die "failed to create reboot trigger file: $!\n";
7106 sub clear_reboot_request
{
7108 my $path = "/run/qemu-server/$vmid.reboot";
7111 $res = unlink($path);
7112 die "could not remove reboot request for $vmid: $!"
7113 if !$res && $! != POSIX
::ENOENT
;
7118 # bash completion helper
7120 sub complete_backup_archives
{
7121 my ($cmdname, $pname, $cvalue) = @_;
7123 my $cfg = PVE
::Storage
::config
();
7127 if ($cvalue =~ m/^([^:]+):/) {
7131 my $data = PVE
::Storage
::template_list
($cfg, $storeid, 'backup');
7134 foreach my $id (keys %$data) {
7135 foreach my $item (@{$data->{$id}}) {
7136 next if $item->{format
} !~ m/^vma\.(gz|lzo)$/;
7137 push @$res, $item->{volid
} if defined($item->{volid
});
7144 my $complete_vmid_full = sub {
7147 my $idlist = vmstatus
();
7151 foreach my $id (keys %$idlist) {
7152 my $d = $idlist->{$id};
7153 if (defined($running)) {
7154 next if $d->{template
};
7155 next if $running && $d->{status
} ne 'running';
7156 next if !$running && $d->{status
} eq 'running';
7165 return &$complete_vmid_full();
7168 sub complete_vmid_stopped
{
7169 return &$complete_vmid_full(0);
7172 sub complete_vmid_running
{
7173 return &$complete_vmid_full(1);
7176 sub complete_storage
{
7178 my $cfg = PVE
::Storage
::config
();
7179 my $ids = $cfg->{ids
};
7182 foreach my $sid (keys %$ids) {
7183 next if !PVE
::Storage
::storage_check_enabled
($cfg, $sid, undef, 1);
7184 next if !$ids->{$sid}->{content
}->{images
};
7191 sub complete_migration_storage
{
7192 my ($cmd, $param, $current_value, $all_args) = @_;
7194 my $targetnode = @$all_args[1];
7196 my $cfg = PVE
::Storage
::config
();
7197 my $ids = $cfg->{ids
};
7200 foreach my $sid (keys %$ids) {
7201 next if !PVE
::Storage
::storage_check_enabled
($cfg, $sid, $targetnode, 1);
7202 next if !$ids->{$sid}->{content
}->{images
};