1 package PVE
::QemuServer
;
11 use File
::Copy
qw(copy);
24 use Storable
qw(dclone);
25 use Time
::HiRes
qw(gettimeofday);
29 use PVE
::Cluster
qw(cfs_register_file cfs_read_file cfs_write_file);
31 use PVE
::DataCenterConfig
;
32 use PVE
::Exception
qw(raise raise_param_exc);
33 use PVE
::Format
qw(render_duration render_bytes);
34 use PVE
::GuestHelpers
qw(safe_string_ne safe_num_ne safe_boolean_ne);
36 use PVE
::JSONSchema
qw(get_standard_option parse_property_string);
39 use PVE
::RPCEnvironment
;
43 use PVE
::Tools
qw(run_command file_read_firstline file_get_contents dir_glob_foreach get_host_arch $IPV6RE);
47 use PVE
::QemuServer
::Helpers
qw(min_version config_aware_timeout);
48 use PVE
::QemuServer
::Cloudinit
;
49 use PVE
::QemuServer
::CGroup
;
50 use PVE
::QemuServer
::CPUConfig
qw(print_cpu_device get_cpu_options);
51 use PVE
::QemuServer
::Drive
qw(is_valid_drivename drive_is_cloudinit drive_is_cdrom drive_is_read_only parse_drive print_drive);
52 use PVE
::QemuServer
::Machine
;
53 use PVE
::QemuServer
::Memory
;
54 use PVE
::QemuServer
::Monitor
qw(mon_cmd);
55 use PVE
::QemuServer
::PCI
qw(print_pci_addr print_pcie_addr print_pcie_root_port parse_hostpci);
56 use PVE
::QemuServer
::USB
qw(parse_usb_device);
60 require PVE
::Network
::SDN
::Zones
;
64 my $EDK2_FW_BASE = '/usr/share/pve-edk2-firmware/';
67 "$EDK2_FW_BASE/OVMF_CODE.fd",
68 "$EDK2_FW_BASE/OVMF_VARS.fd"
71 "$EDK2_FW_BASE/AAVMF_CODE.fd",
72 "$EDK2_FW_BASE/AAVMF_VARS.fd"
76 my $cpuinfo = PVE
::ProcFSTools
::read_cpuinfo
();
78 # Note about locking: we use flock on the config file protect
79 # against concurent actions.
80 # Aditionaly, we have a 'lock' setting in the config file. This
81 # can be set to 'migrate', 'backup', 'snapshot' or 'rollback'. Most actions are not
82 # allowed when such lock is set. But you can ignore this kind of
83 # lock with the --skiplock flag.
85 cfs_register_file
('/qemu-server/',
89 PVE
::JSONSchema
::register_standard_option
('pve-qm-stateuri', {
90 description
=> "Some command save/restore state from this location.",
96 PVE
::JSONSchema
::register_standard_option
('pve-qemu-machine', {
97 description
=> "Specifies the Qemu machine type.",
99 pattern
=> '(pc|pc(-i440fx)?-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|q35|pc-q35-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|virt(?:-\d+(\.\d+)+)?(\+pve\d+)?)',
106 my ($map, $source) = @_;
108 return $source if !defined($map);
110 return $map->{entries
}->{$source}
111 if $map->{entries
} && defined($map->{entries
}->{$source});
113 return $map->{default} if $map->{default};
115 # identity (fallback)
119 PVE
::JSONSchema
::register_standard_option
('pve-targetstorage', {
120 description
=> "Mapping from source to target storages. Providing only a single storage ID maps all source storages to that storage. Providing the special value '1' will map each source storage to itself.",
122 format
=> 'storagepair-list',
126 #no warnings 'redefine';
130 $nodename_cache //= PVE
::INotify
::nodename
();
131 return $nodename_cache;
138 enum
=> [qw(i6300esb ib700)],
139 description
=> "Watchdog type to emulate.",
140 default => 'i6300esb',
145 enum
=> [qw(reset shutdown poweroff pause debug none)],
146 description
=> "The action to perform if after activation the guest fails to poll the watchdog in time.",
150 PVE
::JSONSchema
::register_format
('pve-qm-watchdog', $watchdog_fmt);
154 description
=> "Enable/disable Qemu GuestAgent.",
159 fstrim_cloned_disks
=> {
160 description
=> "Run fstrim after moving a disk or migrating the VM.",
166 description
=> "Select the agent type",
170 enum
=> [qw(virtio isa)],
176 description
=> "Select the VGA type.",
181 enum
=> [qw(cirrus qxl qxl2 qxl3 qxl4 none serial0 serial1 serial2 serial3 std virtio vmware)],
184 description
=> "Sets the VGA memory (in MiB). Has no effect with serial display.",
196 description
=> "The size of the file in MB.",
200 pattern
=> '[a-zA-Z0-9\-]+',
202 format_description
=> 'string',
203 description
=> "The name of the file. Will be prefixed with 'pve-shm-'. Default is the VMID. Will be deleted when the VM is stopped.",
210 enum
=> [qw(ich9-intel-hda intel-hda AC97)],
211 description
=> "Configure an audio device."
215 enum
=> ['spice', 'none'],
218 description
=> "Driver backend for the audio device."
222 my $spice_enhancements_fmt = {
227 description
=> "Enable folder sharing via SPICE. Needs Spice-WebDAV daemon installed in the VM."
231 enum
=> ['off', 'all', 'filter'],
234 description
=> "Enable video streaming. Uses compression for detected video streams."
241 enum
=> ['/dev/urandom', '/dev/random', '/dev/hwrng'],
243 description
=> "The file on the host to gather entropy from. In most"
244 . " cases /dev/urandom should be preferred over /dev/random"
245 . " to avoid entropy-starvation issues on the host. Using"
246 . " urandom does *not* decrease security in any meaningful"
247 . " way, as it's still seeded from real entropy, and the"
248 . " bytes provided will most likely be mixed with real"
249 . " entropy on the guest as well. /dev/hwrng can be used"
250 . " to pass through a hardware RNG from the host.",
254 description
=> "Maximum bytes of entropy injected into the guest every"
255 . " 'period' milliseconds. Prefer a lower value when using"
256 . " /dev/random as source. Use 0 to disable limiting"
257 . " (potentially dangerous!).",
260 # default is 1 KiB/s, provides enough entropy to the guest to avoid
261 # boot-starvation issues (e.g. systemd etc...) while allowing no chance
262 # of overwhelming the host, provided we're reading from /dev/urandom
267 description
=> "Every 'period' milliseconds the entropy-injection quota"
268 . " is reset, allowing the guest to retrieve another"
269 . " 'max_bytes' of entropy.",
279 description
=> "Specifies whether a VM will be started during system bootup.",
285 description
=> "Automatic restart after crash (currently ignored).",
290 type
=> 'string', format
=> 'pve-hotplug-features',
291 description
=> "Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.",
292 default => 'network,disk,usb',
297 description
=> "Allow reboot. If set to '0' the VM exit on reboot.",
303 description
=> "Lock/unlock the VM.",
304 enum
=> [qw(backup clone create migrate rollback snapshot snapshot-delete suspending suspended)],
309 description
=> "Limit of CPU usage.",
310 verbose_description
=> "Limit of CPU usage.\n\nNOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.",
318 description
=> "CPU weight for a VM, will be clamped to [1, 10000] in cgroup v2.",
319 verbose_description
=> "CPU weight for a VM. Argument is used in the kernel fair scheduler."
320 ." The larger the number is, the more CPU time this VM gets. Number is relative to"
321 ." weights of all the other running VMs.",
324 default => 'cgroup v1: 1024, cgroup v2: 100',
329 description
=> "Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.",
336 description
=> "Amount of target RAM for the VM in MB. Using zero disables the ballon driver.",
342 description
=> "Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.",
350 description
=> "Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.cfg' configuration file.".
351 "It should not be necessary to set it.",
352 enum
=> PVE
::Tools
::kvmkeymaplist
(),
357 type
=> 'string', format
=> 'dns-name',
358 description
=> "Set a name for the VM. Only used on the configuration web interface.",
363 description
=> "SCSI controller model",
364 enum
=> [qw(lsi lsi53c810 virtio-scsi-pci virtio-scsi-single megasas pvscsi)],
370 description
=> "Description for the VM. Shown in the web-interface VM's summary."
371 ." This is saved as comment inside the configuration file.",
372 maxLength
=> 1024 * 8,
377 enum
=> [qw(other wxp w2k w2k3 w2k8 wvista win7 win8 win10 l24 l26 solaris)],
378 description
=> "Specify guest operating system.",
379 verbose_description
=> <<EODESC,
380 Specify guest operating system. This is used to enable special
381 optimization/features for specific operating systems:
384 other;; unspecified OS
385 wxp;; Microsoft Windows XP
386 w2k;; Microsoft Windows 2000
387 w2k3;; Microsoft Windows 2003
388 w2k8;; Microsoft Windows 2008
389 wvista;; Microsoft Windows Vista
390 win7;; Microsoft Windows 7
391 win8;; Microsoft Windows 8/2012/2012r2
392 win10;; Microsoft Windows 10/2016/2019
393 l24;; Linux 2.4 Kernel
394 l26;; Linux 2.6 - 5.X Kernel
395 solaris;; Solaris/OpenSolaris/OpenIndiania kernel
400 type
=> 'string', format
=> 'pve-qm-boot',
401 description
=> "Specify guest boot order. Use with 'order=', usage with"
402 . " no key or 'legacy=' is deprecated.",
406 type
=> 'string', format
=> 'pve-qm-bootdisk',
407 description
=> "Enable booting from specified disk. Deprecated: Use 'boot: order=foo;bar' instead.",
408 pattern
=> '(ide|sata|scsi|virtio)\d+',
413 description
=> "The number of CPUs. Please use option -sockets instead.",
420 description
=> "The number of CPU sockets.",
427 description
=> "The number of cores per socket.",
434 description
=> "Enable/disable NUMA.",
440 description
=> "Enable/disable hugepages memory.",
441 enum
=> [qw(any 2 1024)],
447 description
=> "Use together with hugepages. If enabled, hugepages will not not be deleted"
448 ." after VM shutdown and can be used for subsequent starts.",
453 description
=> "Number of hotplugged vcpus.",
460 description
=> "Enable/disable ACPI.",
465 description
=> "Enable/disable Qemu GuestAgent and its properties.",
467 format
=> $agent_fmt,
472 description
=> "Enable/disable KVM hardware virtualization.",
478 description
=> "Enable/disable time drift fix.",
484 description
=> "Set the real time clock to local time. This is enabled by default if ostype"
485 ." indicates a Microsoft OS.",
490 description
=> "Freeze CPU at startup (use 'c' monitor command to start execution).",
494 type
=> 'string', format
=> $vga_fmt,
495 description
=> "Configure the VGA hardware.",
496 verbose_description
=> "Configure the VGA Hardware. If you want to use high resolution"
497 ." modes (>= 1280x1024x16) you may need to increase the vga memory option. Since QEMU"
498 ." 2.9 the default VGA display type is 'std' for all OS types besides some Windows"
499 ." versions (XP and older) which use 'cirrus'. The 'qxl' option enables the SPICE"
500 ." display server. For win* OS you can select how many independent displays you want,"
501 ." Linux guests can add displays them self.\nYou can also run without any graphic card,"
502 ." using a serial device as terminal.",
506 type
=> 'string', format
=> 'pve-qm-watchdog',
507 description
=> "Create a virtual hardware watchdog device.",
508 verbose_description
=> "Create a virtual hardware watchdog device. Once enabled (by a guest"
509 ." action), the watchdog must be periodically polled by an agent inside the guest or"
510 ." else the watchdog will reset the guest (or execute the respective action specified)",
515 typetext
=> "(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)",
516 description
=> "Set the initial date of the real time clock. Valid format for date are:"
517 ."'now' or '2006-06-17T16:01:21' or '2006-06-17'.",
518 pattern
=> '(now|\d{4}-\d{1,2}-\d{1,2}(T\d{1,2}:\d{1,2}:\d{1,2})?)',
521 startup
=> get_standard_option
('pve-startup-order'),
525 description
=> "Enable/disable Template.",
531 description
=> "Arbitrary arguments passed to kvm.",
532 verbose_description
=> <<EODESCR,
533 Arbitrary arguments passed to kvm, for example:
535 args: -no-reboot -no-hpet
537 NOTE: this option is for experts only.
544 description
=> "Enable/disable the USB tablet device.",
545 verbose_description
=> "Enable/disable the USB tablet device. This device is usually needed"
546 ." to allow absolute mouse positioning with VNC. Else the mouse runs out of sync with"
547 ." normal VNC clients. If you're running lots of console-only guests on one host, you"
548 ." may consider disabling this to save some context switches. This is turned off by"
549 ." default if you use spice (`qm set <vmid> --vga qxl`).",
554 description
=> "Set maximum speed (in MB/s) for migrations. Value 0 is no limit.",
558 migrate_downtime
=> {
561 description
=> "Set maximum tolerated downtime (in seconds) for migrations.",
567 type
=> 'string', format
=> 'pve-qm-ide',
568 typetext
=> '<volume>',
569 description
=> "This is an alias for option -ide2",
573 description
=> "Emulated CPU type.",
575 format
=> 'pve-vm-cpu-conf',
577 parent
=> get_standard_option
('pve-snapshot-name', {
579 description
=> "Parent snapshot name. This is used internally, and should not be modified.",
583 description
=> "Timestamp for snapshots.",
589 type
=> 'string', format
=> 'pve-volume-id',
590 description
=> "Reference to a volume which stores the VM state. This is used internally"
593 vmstatestorage
=> get_standard_option
('pve-storage-id', {
594 description
=> "Default storage for VM state volumes/files.",
597 runningmachine
=> get_standard_option
('pve-qemu-machine', {
598 description
=> "Specifies the QEMU machine type of the running vm. This is used internally"
602 description
=> "Specifies the QEMU '-cpu' parameter of the running vm. This is used"
603 ." internally for snapshots.",
606 pattern
=> $PVE::QemuServer
::CPUConfig
::qemu_cmdline_cpu_re
,
607 format_description
=> 'QEMU -cpu parameter'
609 machine
=> get_standard_option
('pve-qemu-machine'),
611 description
=> "Virtual processor architecture. Defaults to the host.",
614 enum
=> [qw(x86_64 aarch64)],
617 description
=> "Specify SMBIOS type 1 fields.",
618 type
=> 'string', format
=> 'pve-qm-smbios1',
625 description
=> "Sets the protection flag of the VM. This will disable the remove VM and"
626 ." remove disk operations.",
632 enum
=> [ qw(seabios ovmf) ],
633 description
=> "Select BIOS implementation.",
634 default => 'seabios',
638 pattern
=> '(?:[a-fA-F0-9]{8}(?:-[a-fA-F0-9]{4}){3}-[a-fA-F0-9]{12}|[01])',
639 format_description
=> 'UUID',
640 description
=> "Set VM Generation ID. Use '1' to autogenerate on create or update, pass '0'"
641 ." to disable explicitly.",
642 verbose_description
=> "The VM generation ID (vmgenid) device exposes a 128-bit integer"
643 ." value identifier to the guest OS. This allows to notify the guest operating system"
644 ." when the virtual machine is executed with a different configuration (e.g. snapshot"
645 ." execution or creation from a template). The guest operating system notices the"
646 ." change, and is then able to react as appropriate by marking its copies of"
647 ." distributed databases as dirty, re-initializing its random number generator, etc.\n"
648 ."Note that auto-creation only works when done through API/CLI create or update methods"
649 .", but not when manually editing the config file.",
650 default => "1 (autogenerated)",
655 format
=> 'pve-volume-id',
657 description
=> "Script that will be executed during various steps in the vms lifetime.",
661 format
=> $ivshmem_fmt,
662 description
=> "Inter-VM shared memory. Useful for direct communication between VMs, or to"
668 format
=> $audio_fmt,
669 description
=> "Configure a audio device, useful in combination with QXL/Spice.",
672 spice_enhancements
=> {
674 format
=> $spice_enhancements_fmt,
675 description
=> "Configure additional enhancements for SPICE.",
679 type
=> 'string', format
=> 'pve-tag-list',
680 description
=> 'Tags of the VM. This is only meta information.',
686 description
=> "Configure a VirtIO-based Random Number Generator.",
695 description
=> 'Specify a custom file containing all meta data passed to the VM via"
696 ." cloud-init. This is provider specific meaning configdrive2 and nocloud differ.',
697 format
=> 'pve-volume-id',
698 format_description
=> 'volume',
703 description
=> 'Specify a custom file containing all network data passed to the VM via'
705 format
=> 'pve-volume-id',
706 format_description
=> 'volume',
711 description
=> 'Specify a custom file containing all user data passed to the VM via'
713 format
=> 'pve-volume-id',
714 format_description
=> 'volume',
717 PVE
::JSONSchema
::register_format
('pve-qm-cicustom', $cicustom_fmt);
719 my $confdesc_cloudinit = {
723 description
=> 'Specifies the cloud-init configuration format. The default depends on the'
724 .' configured operating system type (`ostype`. We use the `nocloud` format for Linux,'
725 .' and `configdrive2` for windows.',
726 enum
=> ['configdrive2', 'nocloud', 'opennebula'],
731 description
=> "cloud-init: User name to change ssh keys and password for instead of the"
732 ." image's configured default user.",
737 description
=> 'cloud-init: Password to assign the user. Using this is generally not'
738 .' recommended. Use ssh keys instead. Also note that older cloud-init versions do not'
739 .' support hashed passwords.',
744 description
=> 'cloud-init: Specify custom files to replace the automatically generated'
746 format
=> 'pve-qm-cicustom',
751 description
=> "cloud-init: Sets DNS search domains for a container. Create will'
752 .' automatically use the setting from the host if neither searchdomain nor nameserver'
757 type
=> 'string', format
=> 'address-list',
758 description
=> "cloud-init: Sets DNS server IP address for a container. Create will'
759 .' automatically use the setting from the host if neither searchdomain nor nameserver'
765 format
=> 'urlencoded',
766 description
=> "cloud-init: Setup public SSH keys (one key per line, OpenSSH format).",
770 # what about other qemu settings ?
772 #machine => 'string',
785 ##soundhw => 'string',
787 while (my ($k, $v) = each %$confdesc) {
788 PVE
::JSONSchema
::register_standard_option
("pve-qm-$k", $v);
791 my $MAX_USB_DEVICES = 5;
793 my $MAX_SERIAL_PORTS = 4;
794 my $MAX_PARALLEL_PORTS = 3;
800 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
801 description
=> "CPUs accessing this NUMA node.",
802 format_description
=> "id[-id];...",
806 description
=> "Amount of memory this NUMA node provides.",
811 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
812 description
=> "Host NUMA nodes to use.",
813 format_description
=> "id[-id];...",
818 enum
=> [qw(preferred bind interleave)],
819 description
=> "NUMA allocation policy.",
823 PVE
::JSONSchema
::register_format
('pve-qm-numanode', $numa_fmt);
826 type
=> 'string', format
=> $numa_fmt,
827 description
=> "NUMA topology.",
829 PVE
::JSONSchema
::register_standard_option
("pve-qm-numanode", $numadesc);
831 for (my $i = 0; $i < $MAX_NUMA; $i++) {
832 $confdesc->{"numa$i"} = $numadesc;
835 my $nic_model_list = [
851 my $nic_model_list_txt = join(' ', sort @$nic_model_list);
853 my $net_fmt_bridge_descr = <<__EOD__;
854 Bridge to attach the network device to. The Proxmox VE standard bridge
857 If you do not specify a bridge, we create a kvm user (NATed) network
858 device, which provides DHCP and DNS services. The following addresses
865 The DHCP server assign addresses to the guest starting from 10.0.2.15.
869 macaddr
=> get_standard_option
('mac-addr', {
870 description
=> "MAC address. That address must be unique withing your network. This is"
871 ." automatically generated if not specified.",
875 description
=> "Network Card Model. The 'virtio' model provides the best performance with"
876 ." very low CPU overhead. If your guest does not support this driver, it is usually"
877 ." best to use 'e1000'.",
878 enum
=> $nic_model_list,
881 (map { $_ => { keyAlias
=> 'model', alias
=> 'macaddr' }} @$nic_model_list),
884 description
=> $net_fmt_bridge_descr,
885 format_description
=> 'bridge',
886 pattern
=> '[-_.\w\d]+',
891 minimum
=> 0, maximum
=> 16,
892 description
=> 'Number of packet queues to be used on the device.',
898 description
=> "Rate limit in mbps (megabytes per second) as floating point number.",
903 minimum
=> 1, maximum
=> 4094,
904 description
=> 'VLAN tag to apply to packets on this interface.',
909 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
910 description
=> 'VLAN trunks to pass through this interface.',
911 format_description
=> 'vlanid[;vlanid...]',
916 description
=> 'Whether this interface should be protected by the firewall.',
921 description
=> 'Whether this interface should be disconnected (like pulling the plug).',
926 minimum
=> 1, maximum
=> 65520,
927 description
=> "Force MTU, for VirtIO only. Set to '1' to use the bridge MTU",
934 type
=> 'string', format
=> $net_fmt,
935 description
=> "Specify network devices.",
938 PVE
::JSONSchema
::register_standard_option
("pve-qm-net", $netdesc);
943 format
=> 'pve-ipv4-config',
944 format_description
=> 'IPv4Format/CIDR',
945 description
=> 'IPv4 address in CIDR format.',
952 format_description
=> 'GatewayIPv4',
953 description
=> 'Default gateway for IPv4 traffic.',
959 format
=> 'pve-ipv6-config',
960 format_description
=> 'IPv6Format/CIDR',
961 description
=> 'IPv6 address in CIDR format.',
968 format_description
=> 'GatewayIPv6',
969 description
=> 'Default gateway for IPv6 traffic.',
974 PVE
::JSONSchema
::register_format
('pve-qm-ipconfig', $ipconfig_fmt);
977 type
=> 'string', format
=> 'pve-qm-ipconfig',
978 description
=> <<'EODESCR',
979 cloud-init: Specify IP addresses and gateways for the corresponding interface.
981 IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
983 The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit
984 gateway should be provided.
985 For IPv6 the special string 'auto' can be used to use stateless autoconfiguration. This requires
986 cloud-init 19.4 or newer.
988 If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using
992 PVE
::JSONSchema
::register_standard_option
("pve-qm-ipconfig", $netdesc);
994 for (my $i = 0; $i < $MAX_NETS; $i++) {
995 $confdesc->{"net$i"} = $netdesc;
996 $confdesc_cloudinit->{"ipconfig$i"} = $ipconfigdesc;
999 foreach my $key (keys %$confdesc_cloudinit) {
1000 $confdesc->{$key} = $confdesc_cloudinit->{$key};
1003 PVE
::JSONSchema
::register_format
('pve-volume-id-or-qm-path', \
&verify_volume_id_or_qm_path
);
1004 sub verify_volume_id_or_qm_path
{
1005 my ($volid, $noerr) = @_;
1007 if ($volid eq 'none' || $volid eq 'cdrom' || $volid =~ m
|^/|) {
1011 # if its neither 'none' nor 'cdrom' nor a path, check if its a volume-id
1012 $volid = eval { PVE
::JSONSchema
::check_format
('pve-volume-id', $volid, '') };
1023 type
=> 'string', format
=> 'pve-qm-usb-device',
1024 format_description
=> 'HOSTUSBDEVICE|spice',
1025 description
=> <<EODESCR,
1026 The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
1028 'bus-port(.port)*' (decimal numbers) or
1029 'vendor_id:product_id' (hexadeciaml numbers) or
1032 You can use the 'lsusb -t' command to list existing usb devices.
1034 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
1035 machines - use with special care.
1037 The value 'spice' can be used to add a usb redirection devices for spice.
1043 description
=> "Specifies whether if given host option is a USB3 device or port.",
1050 type
=> 'string', format
=> $usb_fmt,
1051 description
=> "Configure an USB device (n is 0 to 4).",
1053 PVE
::JSONSchema
::register_standard_option
("pve-qm-usb", $usbdesc);
1058 pattern
=> '(/dev/.+|socket)',
1059 description
=> "Create a serial device inside the VM (n is 0 to 3)",
1060 verbose_description
=> <<EODESCR,
1061 Create a serial device inside the VM (n is 0 to 3), and pass through a
1062 host serial device (i.e. /dev/ttyS0), or create a unix socket on the
1063 host side (use 'qm terminal' to open a terminal connection).
1065 NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines -
1066 use with special care.
1068 CAUTION: Experimental! User reported problems with this option.
1075 pattern
=> '/dev/parport\d+|/dev/usb/lp\d+',
1076 description
=> "Map host parallel devices (n is 0 to 2).",
1077 verbose_description
=> <<EODESCR,
1078 Map host parallel devices (n is 0 to 2).
1080 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
1081 machines - use with special care.
1083 CAUTION: Experimental! User reported problems with this option.
1087 for (my $i = 0; $i < $MAX_PARALLEL_PORTS; $i++) {
1088 $confdesc->{"parallel$i"} = $paralleldesc;
1091 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
1092 $confdesc->{"serial$i"} = $serialdesc;
1095 for (my $i = 0; $i < $PVE::QemuServer
::PCI
::MAX_HOSTPCI_DEVICES
; $i++) {
1096 $confdesc->{"hostpci$i"} = $PVE::QemuServer
::PCI
::hostpcidesc
;
1099 for my $key (keys %{$PVE::QemuServer
::Drive
::drivedesc_hash
}) {
1100 $confdesc->{$key} = $PVE::QemuServer
::Drive
::drivedesc_hash-
>{$key};
1103 for (my $i = 0; $i < $MAX_USB_DEVICES; $i++) {
1104 $confdesc->{"usb$i"} = $usbdesc;
1112 description
=> "Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n)."
1113 . " Deprecated, use 'order=' instead.",
1114 pattern
=> '[acdn]{1,4}',
1115 format_description
=> "[acdn]{1,4}",
1117 # note: this is also the fallback if boot: is not given at all
1123 format
=> 'pve-qm-bootdev-list',
1124 format_description
=> "device[;device...]",
1125 description
=> <<EODESC,
1126 The guest will attempt to boot from devices in the order they appear here.
1128 Disks, optical drives and passed-through storage USB devices will be directly
1129 booted from, NICs will load PXE, and PCIe devices will either behave like disks
1130 (e.g. NVMe) or load an option ROM (e.g. RAID controller, hardware NIC).
1132 Note that only devices in this list will be marked as bootable and thus loaded
1133 by the guest firmware (BIOS/UEFI). If you require multiple disks for booting
1134 (e.g. software-raid), you need to specify all of them here.
1136 Overrides the deprecated 'legacy=[acdn]*' value when given.
1140 PVE
::JSONSchema
::register_format
('pve-qm-boot', $boot_fmt);
1142 PVE
::JSONSchema
::register_format
('pve-qm-bootdev', \
&verify_bootdev
);
1143 sub verify_bootdev
{
1144 my ($dev, $noerr) = @_;
1146 return $dev if PVE
::QemuServer
::Drive
::is_valid_drivename
($dev) && $dev !~ m/^efidisk/;
1150 return 0 if $dev !~ m/^$base\d+$/;
1151 return 0 if !$confdesc->{$dev};
1155 return $dev if $check->("net");
1156 return $dev if $check->("usb");
1157 return $dev if $check->("hostpci");
1160 die "invalid boot device '$dev'\n";
1163 sub print_bootorder
{
1165 return "" if !@$devs;
1166 my $data = { order
=> join(';', @$devs) };
1167 return PVE
::JSONSchema
::print_property_string
($data, $boot_fmt);
1170 my $kvm_api_version = 0;
1173 return $kvm_api_version if $kvm_api_version;
1175 open my $fh, '<', '/dev/kvm' or return;
1177 # 0xae00 => KVM_GET_API_VERSION
1178 $kvm_api_version = ioctl($fh, 0xae00, 0);
1181 return $kvm_api_version;
1184 my $kvm_user_version = {};
1187 sub kvm_user_version
{
1190 $binary //= get_command_for_arch
(get_host_arch
()); # get the native arch by default
1191 my $st = stat($binary);
1193 my $cachedmtime = $kvm_mtime->{$binary} // -1;
1194 return $kvm_user_version->{$binary} if $kvm_user_version->{$binary} &&
1195 $cachedmtime == $st->mtime;
1197 $kvm_user_version->{$binary} = 'unknown';
1198 $kvm_mtime->{$binary} = $st->mtime;
1202 if ($line =~ m/^QEMU( PC)? emulator version (\d+\.\d+(\.\d+)?)(\.\d+)?[,\s]/) {
1203 $kvm_user_version->{$binary} = $2;
1207 eval { run_command
([$binary, '--version'], outfunc
=> $code); };
1210 return $kvm_user_version->{$binary};
1213 my sub extract_version
{
1214 my ($machine_type, $version) = @_;
1215 $version = kvm_user_version
() if !defined($version);
1216 PVE
::QemuServer
::Machine
::extract_version
($machine_type, $version)
1219 sub kernel_has_vhost_net
{
1220 return -c
'/dev/vhost-net';
1225 return defined($confdesc->{$key});
1229 sub get_cdrom_path
{
1231 return $cdrom_path if $cdrom_path;
1233 return $cdrom_path = "/dev/cdrom" if -l
"/dev/cdrom";
1234 return $cdrom_path = "/dev/cdrom1" if -l
"/dev/cdrom1";
1235 return $cdrom_path = "/dev/cdrom2" if -l
"/dev/cdrom2";
1239 my ($storecfg, $vmid, $cdrom) = @_;
1241 if ($cdrom eq 'cdrom') {
1242 return get_cdrom_path
();
1243 } elsif ($cdrom eq 'none') {
1245 } elsif ($cdrom =~ m
|^/|) {
1248 return PVE
::Storage
::path
($storecfg, $cdrom);
1252 # try to convert old style file names to volume IDs
1253 sub filename_to_volume_id
{
1254 my ($vmid, $file, $media) = @_;
1256 if (!($file eq 'none' || $file eq 'cdrom' ||
1257 $file =~ m
|^/dev/.+| || $file =~ m/^([^:]+):(.+)$/)) {
1259 return if $file =~ m
|/|;
1261 if ($media && $media eq 'cdrom') {
1262 $file = "local:iso/$file";
1264 $file = "local:$vmid/$file";
1271 sub verify_media_type
{
1272 my ($opt, $vtype, $media) = @_;
1277 if ($media eq 'disk') {
1279 } elsif ($media eq 'cdrom') {
1282 die "internal error";
1285 return if ($vtype eq $etype);
1287 raise_param_exc
({ $opt => "unexpected media type ($vtype != $etype)" });
1290 sub cleanup_drive_path
{
1291 my ($opt, $storecfg, $drive) = @_;
1293 # try to convert filesystem paths to volume IDs
1295 if (($drive->{file
} !~ m/^(cdrom|none)$/) &&
1296 ($drive->{file
} !~ m
|^/dev/.+|) &&
1297 ($drive->{file
} !~ m/^([^:]+):(.+)$/) &&
1298 ($drive->{file
} !~ m/^\d+$/)) {
1299 my ($vtype, $volid) = PVE
::Storage
::path_to_volume_id
($storecfg, $drive->{file
});
1300 raise_param_exc
({ $opt => "unable to associate path '$drive->{file}' to any storage"})
1302 $drive->{media
} = 'cdrom' if !$drive->{media
} && $vtype eq 'iso';
1303 verify_media_type
($opt, $vtype, $drive->{media
});
1304 $drive->{file
} = $volid;
1307 $drive->{media
} = 'cdrom' if !$drive->{media
} && $drive->{file
} =~ m/^(cdrom|none)$/;
1310 sub parse_hotplug_features
{
1315 return $res if $data eq '0';
1317 $data = $confdesc->{hotplug
}->{default} if $data eq '1';
1319 foreach my $feature (PVE
::Tools
::split_list
($data)) {
1320 if ($feature =~ m/^(network|disk|cpu|memory|usb)$/) {
1323 die "invalid hotplug feature '$feature'\n";
1329 PVE
::JSONSchema
::register_format
('pve-hotplug-features', \
&pve_verify_hotplug_features
);
1330 sub pve_verify_hotplug_features
{
1331 my ($value, $noerr) = @_;
1333 return $value if parse_hotplug_features
($value);
1337 die "unable to parse hotplug option\n";
1341 my($fh, $noerr) = @_;
1344 my $SG_GET_VERSION_NUM = 0x2282;
1346 my $versionbuf = "\x00" x
8;
1347 my $ret = ioctl($fh, $SG_GET_VERSION_NUM, $versionbuf);
1349 die "scsi ioctl SG_GET_VERSION_NUM failoed - $!\n" if !$noerr;
1352 my $version = unpack("I", $versionbuf);
1353 if ($version < 30000) {
1354 die "scsi generic interface too old\n" if !$noerr;
1358 my $buf = "\x00" x
36;
1359 my $sensebuf = "\x00" x
8;
1360 my $cmd = pack("C x3 C x1", 0x12, 36);
1362 # see /usr/include/scsi/sg.h
1363 my $sg_io_hdr_t = "i i C C s I P P P I I i P C C C C S S i I I";
1365 my $packet = pack($sg_io_hdr_t, ord('S'), -3, length($cmd),
1366 length($sensebuf), 0, length($buf), $buf,
1367 $cmd, $sensebuf, 6000);
1369 $ret = ioctl($fh, $SG_IO, $packet);
1371 die "scsi ioctl SG_IO failed - $!\n" if !$noerr;
1375 my @res = unpack($sg_io_hdr_t, $packet);
1376 if ($res[17] || $res[18]) {
1377 die "scsi ioctl SG_IO status error - $!\n" if !$noerr;
1382 (my $byte0, my $byte1, $res->{vendor
},
1383 $res->{product
}, $res->{revision
}) = unpack("C C x6 A8 A16 A4", $buf);
1385 $res->{removable
} = $byte1 & 128 ?
1 : 0;
1386 $res->{type
} = $byte0 & 31;
1394 my $fh = IO
::File-
>new("+<$path") || return;
1395 my $res = scsi_inquiry
($fh, 1);
1401 sub print_tabletdevice_full
{
1402 my ($conf, $arch) = @_;
1404 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
1406 # we use uhci for old VMs because tablet driver was buggy in older qemu
1408 if (PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf) || $arch eq 'aarch64') {
1414 return "usb-tablet,id=tablet,bus=$usbbus.0,port=1";
1417 sub print_keyboarddevice_full
{
1418 my ($conf, $arch, $machine) = @_;
1420 return if $arch ne 'aarch64';
1422 return "usb-kbd,id=keyboard,bus=ehci.0,port=2";
1425 my sub get_drive_id
{
1427 return "$drive->{interface}$drive->{index}";
1430 sub print_drivedevice_full
{
1431 my ($storecfg, $conf, $vmid, $drive, $bridges, $arch, $machine_type) = @_;
1436 my $drive_id = get_drive_id
($drive);
1437 if ($drive->{interface
} eq 'virtio') {
1438 my $pciaddr = print_pci_addr
("$drive_id", $bridges, $arch, $machine_type);
1439 $device = "virtio-blk-pci,drive=drive-$drive_id,id=${drive_id}${pciaddr}";
1440 $device .= ",iothread=iothread-$drive_id" if $drive->{iothread
};
1441 } elsif ($drive->{interface
} eq 'scsi') {
1443 my ($maxdev, $controller, $controller_prefix) = scsihw_infos
($conf, $drive);
1444 my $unit = $drive->{index} % $maxdev;
1445 my $devicetype = 'hd';
1447 if (drive_is_cdrom
($drive)) {
1450 if ($drive->{file
} =~ m
|^/|) {
1451 $path = $drive->{file
};
1452 if (my $info = path_is_scsi
($path)) {
1453 if ($info->{type
} == 0 && $drive->{scsiblock
}) {
1454 $devicetype = 'block';
1455 } elsif ($info->{type
} == 1) { # tape
1456 $devicetype = 'generic';
1460 $path = PVE
::Storage
::path
($storecfg, $drive->{file
});
1463 # for compatibility only, we prefer scsi-hd (#2408, #2355, #2380)
1464 my $version = extract_version
($machine_type, kvm_user_version
());
1465 if ($path =~ m/^iscsi\:\/\
// &&
1466 !min_version
($version, 4, 1)) {
1467 $devicetype = 'generic';
1471 if (!$conf->{scsihw
} || $conf->{scsihw
} =~ m/^lsi/ || $conf->{scsihw
} eq 'pvscsi') {
1472 $device = "scsi-$devicetype,bus=$controller_prefix$controller.0,scsi-id=$unit";
1474 $device = "scsi-$devicetype,bus=$controller_prefix$controller.0,channel=0,scsi-id=0"
1475 .",lun=$drive->{index}";
1477 $device .= ",drive=drive-$drive_id,id=$drive_id";
1479 if ($drive->{ssd
} && ($devicetype eq 'block' || $devicetype eq 'hd')) {
1480 $device .= ",rotation_rate=1";
1482 $device .= ",wwn=$drive->{wwn}" if $drive->{wwn
};
1484 } elsif ($drive->{interface
} eq 'ide' || $drive->{interface
} eq 'sata') {
1485 my $maxdev = ($drive->{interface
} eq 'sata') ?
$PVE::QemuServer
::Drive
::MAX_SATA_DISKS
: 2;
1486 my $controller = int($drive->{index} / $maxdev);
1487 my $unit = $drive->{index} % $maxdev;
1488 my $devicetype = ($drive->{media
} && $drive->{media
} eq 'cdrom') ?
"cd" : "hd";
1490 $device = "ide-$devicetype";
1491 if ($drive->{interface
} eq 'ide') {
1492 $device .= ",bus=ide.$controller,unit=$unit";
1494 $device .= ",bus=ahci$controller.$unit";
1496 $device .= ",drive=drive-$drive_id,id=$drive_id";
1498 if ($devicetype eq 'hd') {
1499 if (my $model = $drive->{model
}) {
1500 $model = URI
::Escape
::uri_unescape
($model);
1501 $device .= ",model=$model";
1503 if ($drive->{ssd
}) {
1504 $device .= ",rotation_rate=1";
1507 $device .= ",wwn=$drive->{wwn}" if $drive->{wwn
};
1508 } elsif ($drive->{interface
} eq 'usb') {
1510 # -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0
1512 die "unsupported interface type";
1515 $device .= ",bootindex=$drive->{bootindex}" if $drive->{bootindex
};
1517 if (my $serial = $drive->{serial
}) {
1518 $serial = URI
::Escape
::uri_unescape
($serial);
1519 $device .= ",serial=$serial";
1526 sub get_initiator_name
{
1529 my $fh = IO
::File-
>new('/etc/iscsi/initiatorname.iscsi') || return;
1530 while (defined(my $line = <$fh>)) {
1531 next if $line !~ m/^\s*InitiatorName\s*=\s*([\.\-:\w]+)/;
1540 sub print_drive_commandline_full
{
1541 my ($storecfg, $vmid, $drive, $pbs_name, $io_uring) = @_;
1544 my $volid = $drive->{file
};
1545 my $format = $drive->{format
};
1546 my $drive_id = get_drive_id
($drive);
1548 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
1549 my $scfg = $storeid ? PVE
::Storage
::storage_config
($storecfg, $storeid) : undef;
1551 if (drive_is_cdrom
($drive)) {
1552 $path = get_iso_path
($storecfg, $vmid, $volid);
1553 die "$drive_id: cannot back cdrom drive with PBS snapshot\n" if $pbs_name;
1556 $path = PVE
::Storage
::path
($storecfg, $volid);
1557 $format //= qemu_img_format
($scfg, $volname);
1564 my $is_rbd = $path =~ m/^rbd:/;
1567 my @qemu_drive_options = qw(heads secs cyls trans media cache rerror werror aio discard);
1568 foreach my $o (@qemu_drive_options) {
1569 $opts .= ",$o=$drive->{$o}" if defined($drive->{$o});
1572 # snapshot only accepts on|off
1573 if (defined($drive->{snapshot
})) {
1574 my $v = $drive->{snapshot
} ?
'on' : 'off';
1575 $opts .= ",snapshot=$v";
1578 foreach my $type (['', '-total'], [_rd
=> '-read'], [_wr
=> '-write']) {
1579 my ($dir, $qmpname) = @$type;
1580 if (my $v = $drive->{"mbps$dir"}) {
1581 $opts .= ",throttling.bps$qmpname=".int($v*1024*1024);
1583 if (my $v = $drive->{"mbps${dir}_max"}) {
1584 $opts .= ",throttling.bps$qmpname-max=".int($v*1024*1024);
1586 if (my $v = $drive->{"bps${dir}_max_length"}) {
1587 $opts .= ",throttling.bps$qmpname-max-length=$v";
1589 if (my $v = $drive->{"iops${dir}"}) {
1590 $opts .= ",throttling.iops$qmpname=$v";
1592 if (my $v = $drive->{"iops${dir}_max"}) {
1593 $opts .= ",throttling.iops$qmpname-max=$v";
1595 if (my $v = $drive->{"iops${dir}_max_length"}) {
1596 $opts .= ",throttling.iops$qmpname-max-length=$v";
1601 $format = "rbd" if $is_rbd;
1602 die "$drive_id: Proxmox Backup Server backed drive cannot auto-detect the format\n"
1604 $opts .= ",format=alloc-track,file.driver=$format";
1606 $opts .= ",format=$format";
1609 my $cache_direct = 0;
1611 if (my $cache = $drive->{cache
}) {
1612 $cache_direct = $cache =~ /^(?:off|none|directsync)$/;
1613 } elsif (!drive_is_cdrom
($drive) && !($scfg && $scfg->{type
} eq 'btrfs' && !$scfg->{nocow
})) {
1614 $opts .= ",cache=none";
1618 # io_uring with cache mode writeback or writethrough on krbd will hang...
1619 my $rbd_no_io_uring = $scfg && $scfg->{type
} eq 'rbd' && $scfg->{krbd
} && !$cache_direct;
1621 # io_uring with cache mode writeback or writethrough on LVM will hang...
1622 my $lvm_no_io_uring = $scfg && $scfg->{type
} eq 'lvm' && !$cache_direct;
1624 if (!$drive->{aio
}) {
1625 if ($io_uring && !$rbd_no_io_uring && !$lvm_no_io_uring) {
1626 # io_uring supports all cache modes
1627 $opts .= ",aio=io_uring";
1629 # aio native works only with O_DIRECT
1631 $opts .= ",aio=native";
1633 $opts .= ",aio=threads";
1638 if (!drive_is_cdrom
($drive)) {
1640 if (defined($drive->{detect_zeroes
}) && !$drive->{detect_zeroes
}) {
1641 $detectzeroes = 'off';
1642 } elsif ($drive->{discard
}) {
1643 $detectzeroes = $drive->{discard
} eq 'on' ?
'unmap' : 'on';
1645 # This used to be our default with discard not being specified:
1646 $detectzeroes = 'on';
1649 # note: 'detect-zeroes' works per blockdev and we want it to persist
1650 # after the alloc-track is removed, so put it on 'file' directly
1651 my $dz_param = $pbs_name ?
"file.detect-zeroes" : "detect-zeroes";
1652 $opts .= ",$dz_param=$detectzeroes" if $detectzeroes;
1656 $opts .= ",backing=$pbs_name";
1657 $opts .= ",auto-remove=on";
1660 # my $file_param = $pbs_name ? "file.file.filename" : "file";
1661 my $file_param = "file";
1663 # non-rbd drivers require the underlying file to be a seperate block
1664 # node, so add a second .file indirection
1665 $file_param .= ".file" if !$is_rbd;
1666 $file_param .= ".filename";
1668 my $pathinfo = $path ?
"$file_param=$path," : '';
1670 return "${pathinfo}if=none,id=drive-$drive->{interface}$drive->{index}$opts";
1673 sub print_pbs_blockdev
{
1674 my ($pbs_conf, $pbs_name) = @_;
1675 my $blockdev = "driver=pbs,node-name=$pbs_name,read-only=on";
1676 $blockdev .= ",repository=$pbs_conf->{repository}";
1677 $blockdev .= ",snapshot=$pbs_conf->{snapshot}";
1678 $blockdev .= ",archive=$pbs_conf->{archive}";
1679 $blockdev .= ",keyfile=$pbs_conf->{keyfile}" if $pbs_conf->{keyfile
};
1683 sub print_netdevice_full
{
1684 my ($vmid, $conf, $net, $netid, $bridges, $use_old_bios_files, $arch, $machine_type) = @_;
1686 my $device = $net->{model
};
1687 if ($net->{model
} eq 'virtio') {
1688 $device = 'virtio-net-pci';
1691 my $pciaddr = print_pci_addr
("$netid", $bridges, $arch, $machine_type);
1692 my $tmpstr = "$device,mac=$net->{macaddr},netdev=$netid$pciaddr,id=$netid";
1693 if ($net->{queues
} && $net->{queues
} > 1 && $net->{model
} eq 'virtio'){
1694 # Consider we have N queues, the number of vectors needed is 2 * N + 2, i.e., one per in
1695 # and out of each queue plus one config interrupt and control vector queue
1696 my $vectors = $net->{queues
} * 2 + 2;
1697 $tmpstr .= ",vectors=$vectors,mq=on";
1699 $tmpstr .= ",bootindex=$net->{bootindex}" if $net->{bootindex
} ;
1701 if (my $mtu = $net->{mtu
}) {
1702 if ($net->{model
} eq 'virtio' && $net->{bridge
}) {
1703 my $bridge_mtu = PVE
::Network
::read_bridge_mtu
($net->{bridge
});
1706 } elsif ($mtu < 576) {
1707 die "netdev $netid: MTU '$mtu' is smaller than the IP minimum MTU '576'\n";
1708 } elsif ($mtu > $bridge_mtu) {
1709 die "netdev $netid: MTU '$mtu' is bigger than the bridge MTU '$bridge_mtu'\n";
1711 $tmpstr .= ",host_mtu=$mtu";
1713 warn "WARN: netdev $netid: ignoring MTU '$mtu', not using VirtIO or no bridge configured.\n";
1717 if ($use_old_bios_files) {
1719 if ($device eq 'virtio-net-pci') {
1720 $romfile = 'pxe-virtio.rom';
1721 } elsif ($device eq 'e1000') {
1722 $romfile = 'pxe-e1000.rom';
1723 } elsif ($device eq 'e1000e') {
1724 $romfile = 'pxe-e1000e.rom';
1725 } elsif ($device eq 'ne2k') {
1726 $romfile = 'pxe-ne2k_pci.rom';
1727 } elsif ($device eq 'pcnet') {
1728 $romfile = 'pxe-pcnet.rom';
1729 } elsif ($device eq 'rtl8139') {
1730 $romfile = 'pxe-rtl8139.rom';
1732 $tmpstr .= ",romfile=$romfile" if $romfile;
1738 sub print_netdev_full
{
1739 my ($vmid, $conf, $arch, $net, $netid, $hotplug) = @_;
1742 if ($netid =~ m/^net(\d+)$/) {
1746 die "got strange net id '$i'\n" if $i >= ${MAX_NETS
};
1748 my $ifname = "tap${vmid}i$i";
1750 # kvm uses TUNSETIFF ioctl, and that limits ifname length
1751 die "interface name '$ifname' is too long (max 15 character)\n"
1752 if length($ifname) >= 16;
1754 my $vhostparam = '';
1755 if (is_native
($arch)) {
1756 $vhostparam = ',vhost=on' if kernel_has_vhost_net
() && $net->{model
} eq 'virtio';
1759 my $vmname = $conf->{name
} || "vm$vmid";
1762 my $script = $hotplug ?
"pve-bridge-hotplug" : "pve-bridge";
1764 if ($net->{bridge
}) {
1765 $netdev = "type=tap,id=$netid,ifname=${ifname},script=/var/lib/qemu-server/$script"
1766 .",downscript=/var/lib/qemu-server/pve-bridgedown$vhostparam";
1768 $netdev = "type=user,id=$netid,hostname=$vmname";
1771 $netdev .= ",queues=$net->{queues}" if ($net->{queues
} && $net->{model
} eq 'virtio');
1777 'cirrus' => 'cirrus-vga',
1779 'vmware' => 'vmware-svga',
1780 'virtio' => 'virtio-vga',
1783 sub print_vga_device
{
1784 my ($conf, $vga, $arch, $machine_version, $machine, $id, $qxlnum, $bridges) = @_;
1786 my $type = $vga_map->{$vga->{type
}};
1787 if ($arch eq 'aarch64' && defined($type) && $type eq 'virtio-vga') {
1788 $type = 'virtio-gpu';
1790 my $vgamem_mb = $vga->{memory
};
1792 my $max_outputs = '';
1794 $type = $id ?
'qxl' : 'qxl-vga';
1796 if (!$conf->{ostype
} || $conf->{ostype
} =~ m/^(?:l\d\d)|(?:other)$/) {
1797 # set max outputs so linux can have up to 4 qxl displays with one device
1798 if (min_version
($machine_version, 4, 1)) {
1799 $max_outputs = ",max_outputs=4";
1804 die "no devicetype for $vga->{type}\n" if !$type;
1808 if ($vga->{type
} eq 'virtio') {
1809 my $bytes = PVE
::Tools
::convert_size
($vgamem_mb, "mb" => "b");
1810 $memory = ",max_hostmem=$bytes";
1812 # from https://www.spice-space.org/multiple-monitors.html
1813 $memory = ",vgamem_mb=$vga->{memory}";
1814 my $ram = $vgamem_mb * 4;
1815 my $vram = $vgamem_mb * 2;
1816 $memory .= ",ram_size_mb=$ram,vram_size_mb=$vram";
1818 $memory = ",vgamem_mb=$vga->{memory}";
1820 } elsif ($qxlnum && $id) {
1821 $memory = ",ram_size=67108864,vram_size=33554432";
1825 if ($type eq 'VGA' && windows_version
($conf->{ostype
})) {
1826 $edidoff=",edid=off" if (!defined($conf->{bios
}) || $conf->{bios
} ne 'ovmf');
1829 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
1830 my $vgaid = "vga" . ($id // '');
1833 if ($q35 && $vgaid eq 'vga') {
1834 # the first display uses pcie.0 bus on q35 machines
1835 $pciaddr = print_pcie_addr
($vgaid, $bridges, $arch, $machine);
1837 $pciaddr = print_pci_addr
($vgaid, $bridges, $arch, $machine);
1840 return "$type,id=${vgaid}${memory}${max_outputs}${pciaddr}${edidoff}";
1843 sub parse_number_sets
{
1846 foreach my $part (split(/;/, $set)) {
1847 if ($part =~ /^\s*(\d+)(?:-(\d+))?\s*$/) {
1848 die "invalid range: $part ($2 < $1)\n" if defined($2) && $2 < $1;
1849 push @$res, [ $1, $2 ];
1851 die "invalid range: $part\n";
1860 my $res = parse_property_string
($numa_fmt, $data);
1861 $res->{cpus
} = parse_number_sets
($res->{cpus
}) if defined($res->{cpus
});
1862 $res->{hostnodes
} = parse_number_sets
($res->{hostnodes
}) if defined($res->{hostnodes
});
1866 # netX: e1000=XX:XX:XX:XX:XX:XX,bridge=vmbr0,rate=<mbps>
1870 my $res = eval { parse_property_string
($net_fmt, $data) };
1875 if (!defined($res->{macaddr
})) {
1876 my $dc = PVE
::Cluster
::cfs_read_file
('datacenter.cfg');
1877 $res->{macaddr
} = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
});
1882 # ipconfigX ip=cidr,gw=ip,ip6=cidr,gw6=ip
1883 sub parse_ipconfig
{
1886 my $res = eval { parse_property_string
($ipconfig_fmt, $data) };
1892 if ($res->{gw
} && !$res->{ip
}) {
1893 warn 'gateway specified without specifying an IP address';
1896 if ($res->{gw6
} && !$res->{ip6
}) {
1897 warn 'IPv6 gateway specified without specifying an IPv6 address';
1900 if ($res->{gw
} && $res->{ip
} eq 'dhcp') {
1901 warn 'gateway specified together with DHCP';
1904 if ($res->{gw6
} && $res->{ip6
} !~ /^$IPV6RE/) {
1906 warn "IPv6 gateway specified together with $res->{ip6} address";
1910 if (!$res->{ip
} && !$res->{ip6
}) {
1911 return { ip
=> 'dhcp', ip6
=> 'dhcp' };
1920 return PVE
::JSONSchema
::print_property_string
($net, $net_fmt);
1923 sub add_random_macs
{
1924 my ($settings) = @_;
1926 foreach my $opt (keys %$settings) {
1927 next if $opt !~ m/^net(\d+)$/;
1928 my $net = parse_net
($settings->{$opt});
1930 $settings->{$opt} = print_net
($net);
1934 sub vm_is_volid_owner
{
1935 my ($storecfg, $vmid, $volid) = @_;
1937 if ($volid !~ m
|^/|) {
1939 eval { ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid); };
1940 if ($owner && ($owner == $vmid)) {
1948 sub vmconfig_register_unused_drive
{
1949 my ($storecfg, $vmid, $conf, $drive) = @_;
1951 if (drive_is_cloudinit
($drive)) {
1952 eval { PVE
::Storage
::vdisk_free
($storecfg, $drive->{file
}) };
1954 } elsif (!drive_is_cdrom
($drive)) {
1955 my $volid = $drive->{file
};
1956 if (vm_is_volid_owner
($storecfg, $vmid, $volid)) {
1957 PVE
::QemuConfig-
>add_unused_volume($conf, $volid, $vmid);
1962 # smbios: [manufacturer=str][,product=str][,version=str][,serial=str][,uuid=uuid][,sku=str][,family=str][,base64=bool]
1966 pattern
=> '[a-fA-F0-9]{8}(?:-[a-fA-F0-9]{4}){3}-[a-fA-F0-9]{12}',
1967 format_description
=> 'UUID',
1968 description
=> "Set SMBIOS1 UUID.",
1973 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1974 format_description
=> 'Base64 encoded string',
1975 description
=> "Set SMBIOS1 version.",
1980 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1981 format_description
=> 'Base64 encoded string',
1982 description
=> "Set SMBIOS1 serial number.",
1987 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1988 format_description
=> 'Base64 encoded string',
1989 description
=> "Set SMBIOS1 manufacturer.",
1994 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1995 format_description
=> 'Base64 encoded string',
1996 description
=> "Set SMBIOS1 product ID.",
2001 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
2002 format_description
=> 'Base64 encoded string',
2003 description
=> "Set SMBIOS1 SKU string.",
2008 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
2009 format_description
=> 'Base64 encoded string',
2010 description
=> "Set SMBIOS1 family string.",
2015 description
=> 'Flag to indicate that the SMBIOS values are base64 encoded',
2023 my $res = eval { parse_property_string
($smbios1_fmt, $data) };
2030 return PVE
::JSONSchema
::print_property_string
($smbios1, $smbios1_fmt);
2033 PVE
::JSONSchema
::register_format
('pve-qm-smbios1', $smbios1_fmt);
2035 sub parse_watchdog
{
2040 my $res = eval { parse_property_string
($watchdog_fmt, $value) };
2045 sub parse_guest_agent
{
2048 return {} if !defined($conf->{agent
});
2050 my $res = eval { parse_property_string
($agent_fmt, $conf->{agent
}) };
2053 # if the agent is disabled ignore the other potentially set properties
2054 return {} if !$res->{enabled
};
2059 my ($conf, $key) = @_;
2060 return undef if !defined($conf->{agent
});
2062 my $agent = parse_guest_agent
($conf);
2063 return $agent->{$key};
2069 return {} if !$value;
2070 my $res = eval { parse_property_string
($vga_fmt, $value) };
2080 my $res = eval { parse_property_string
($rng_fmt, $value) };
2085 PVE
::JSONSchema
::register_format
('pve-qm-usb-device', \
&verify_usb_device
);
2086 sub verify_usb_device
{
2087 my ($value, $noerr) = @_;
2089 return $value if parse_usb_device
($value);
2093 die "unable to parse usb device\n";
2096 # add JSON properties for create and set function
2097 sub json_config_properties
{
2100 foreach my $opt (keys %$confdesc) {
2101 next if $opt eq 'parent' || $opt eq 'snaptime' || $opt eq 'vmstate' ||
2102 $opt eq 'runningmachine' || $opt eq 'runningcpu';
2103 $prop->{$opt} = $confdesc->{$opt};
2109 # return copy of $confdesc_cloudinit to generate documentation
2110 sub cloudinit_config_properties
{
2112 return dclone
($confdesc_cloudinit);
2116 my ($key, $value) = @_;
2118 die "unknown setting '$key'\n" if !$confdesc->{$key};
2120 my $type = $confdesc->{$key}->{type
};
2122 if (!defined($value)) {
2123 die "got undefined value\n";
2126 if ($value =~ m/[\n\r]/) {
2127 die "property contains a line feed\n";
2130 if ($type eq 'boolean') {
2131 return 1 if ($value eq '1') || ($value =~ m/^(on|yes|true)$/i);
2132 return 0 if ($value eq '0') || ($value =~ m/^(off|no|false)$/i);
2133 die "type check ('boolean') failed - got '$value'\n";
2134 } elsif ($type eq 'integer') {
2135 return int($1) if $value =~ m/^(\d+)$/;
2136 die "type check ('integer') failed - got '$value'\n";
2137 } elsif ($type eq 'number') {
2138 return $value if $value =~ m/^(\d+)(\.\d+)?$/;
2139 die "type check ('number') failed - got '$value'\n";
2140 } elsif ($type eq 'string') {
2141 if (my $fmt = $confdesc->{$key}->{format
}) {
2142 PVE
::JSONSchema
::check_format
($fmt, $value);
2145 $value =~ s/^\"(.*)\"$/$1/;
2148 die "internal error"
2153 my ($storecfg, $vmid, $skiplock, $replacement_conf, $purge_unreferenced) = @_;
2155 my $conf = PVE
::QemuConfig-
>load_config($vmid);
2157 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
2159 if ($conf->{template
}) {
2160 # check if any base image is still used by a linked clone
2161 PVE
::QemuConfig-
>foreach_volume_full($conf, { include_unused
=> 1 }, sub {
2162 my ($ds, $drive) = @_;
2163 return if drive_is_cdrom
($drive);
2165 my $volid = $drive->{file
};
2166 return if !$volid || $volid =~ m
|^/|;
2168 die "base volume '$volid' is still in use by linked cloned\n"
2169 if PVE
::Storage
::volume_is_base_and_used
($storecfg, $volid);
2174 my $remove_owned_drive = sub {
2175 my ($ds, $drive) = @_;
2176 return if drive_is_cdrom
($drive, 1);
2178 my $volid = $drive->{file
};
2179 return if !$volid || $volid =~ m
|^/|;
2181 my ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid);
2182 return if !$path || !$owner || ($owner != $vmid);
2184 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid) };
2185 warn "Could not remove disk '$volid', check manually: $@" if $@;
2188 # only remove disks owned by this VM (referenced in the config)
2189 my $include_opts = {
2190 include_unused
=> 1,
2191 extra_keys
=> ['vmstate'],
2193 PVE
::QemuConfig-
>foreach_volume_full($conf, $include_opts, $remove_owned_drive);
2195 for my $snap (values %{$conf->{snapshots
}}) {
2196 next if !defined($snap->{vmstate
});
2197 my $drive = PVE
::QemuConfig-
>parse_volume('vmstate', $snap->{vmstate
}, 1);
2198 next if !defined($drive);
2199 $remove_owned_drive->('vmstate', $drive);
2202 if ($purge_unreferenced) { # also remove unreferenced disk
2203 my $vmdisks = PVE
::Storage
::vdisk_list
($storecfg, undef, $vmid, undef, 'images');
2204 PVE
::Storage
::foreach_volid
($vmdisks, sub {
2205 my ($volid, $sid, $volname, $d) = @_;
2206 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid) };
2211 if (defined $replacement_conf) {
2212 PVE
::QemuConfig-
>write_config($vmid, $replacement_conf);
2214 PVE
::QemuConfig-
>destroy_config($vmid);
2218 sub parse_vm_config
{
2219 my ($filename, $raw) = @_;
2221 return if !defined($raw);
2224 digest
=> Digest
::SHA
::sha1_hex
($raw),
2229 $filename =~ m
|/qemu-server/(\d
+)\
.conf
$|
2230 || die "got strange filename '$filename'";
2238 my @lines = split(/\n/, $raw);
2239 foreach my $line (@lines) {
2240 next if $line =~ m/^\s*$/;
2242 if ($line =~ m/^\[PENDING\]\s*$/i) {
2243 $section = 'pending';
2244 if (defined($descr)) {
2246 $conf->{description
} = $descr;
2249 $conf = $res->{$section} = {};
2252 } elsif ($line =~ m/^\[([a-z][a-z0-9_\-]+)\]\s*$/i) {
2254 if (defined($descr)) {
2256 $conf->{description
} = $descr;
2259 $conf = $res->{snapshots
}->{$section} = {};
2263 if ($line =~ m/^\#(.*)\s*$/) {
2264 $descr = '' if !defined($descr);
2265 $descr .= PVE
::Tools
::decode_text
($1) . "\n";
2269 if ($line =~ m/^(description):\s*(.*\S)\s*$/) {
2270 $descr = '' if !defined($descr);
2271 $descr .= PVE
::Tools
::decode_text
($2);
2272 } elsif ($line =~ m/snapstate:\s*(prepare|delete)\s*$/) {
2273 $conf->{snapstate
} = $1;
2274 } elsif ($line =~ m/^(args):\s*(.*\S)\s*$/) {
2277 $conf->{$key} = $value;
2278 } elsif ($line =~ m/^delete:\s*(.*\S)\s*$/) {
2280 if ($section eq 'pending') {
2281 $conf->{delete} = $value; # we parse this later
2283 warn "vm $vmid - propertry 'delete' is only allowed in [PENDING]\n";
2285 } elsif ($line =~ m/^([a-z][a-z_]*\d*):\s*(.+?)\s*$/) {
2288 eval { $value = check_type
($key, $value); };
2290 warn "vm $vmid - unable to parse value of '$key' - $@";
2292 $key = 'ide2' if $key eq 'cdrom';
2293 my $fmt = $confdesc->{$key}->{format
};
2294 if ($fmt && $fmt =~ /^pve-qm-(?:ide|scsi|virtio|sata)$/) {
2295 my $v = parse_drive
($key, $value);
2296 if (my $volid = filename_to_volume_id
($vmid, $v->{file
}, $v->{media
})) {
2297 $v->{file
} = $volid;
2298 $value = print_drive
($v);
2300 warn "vm $vmid - unable to parse value of '$key'\n";
2305 $conf->{$key} = $value;
2308 warn "vm $vmid - unable to parse config: $line\n";
2312 if (defined($descr)) {
2314 $conf->{description
} = $descr;
2316 delete $res->{snapstate
}; # just to be sure
2321 sub write_vm_config
{
2322 my ($filename, $conf) = @_;
2324 delete $conf->{snapstate
}; # just to be sure
2326 if ($conf->{cdrom
}) {
2327 die "option ide2 conflicts with cdrom\n" if $conf->{ide2
};
2328 $conf->{ide2
} = $conf->{cdrom
};
2329 delete $conf->{cdrom
};
2332 # we do not use 'smp' any longer
2333 if ($conf->{sockets
}) {
2334 delete $conf->{smp
};
2335 } elsif ($conf->{smp
}) {
2336 $conf->{sockets
} = $conf->{smp
};
2337 delete $conf->{cores
};
2338 delete $conf->{smp
};
2341 my $used_volids = {};
2343 my $cleanup_config = sub {
2344 my ($cref, $pending, $snapname) = @_;
2346 foreach my $key (keys %$cref) {
2347 next if $key eq 'digest' || $key eq 'description' || $key eq 'snapshots' ||
2348 $key eq 'snapstate' || $key eq 'pending';
2349 my $value = $cref->{$key};
2350 if ($key eq 'delete') {
2351 die "propertry 'delete' is only allowed in [PENDING]\n"
2353 # fixme: check syntax?
2356 eval { $value = check_type
($key, $value); };
2357 die "unable to parse value of '$key' - $@" if $@;
2359 $cref->{$key} = $value;
2361 if (!$snapname && is_valid_drivename
($key)) {
2362 my $drive = parse_drive
($key, $value);
2363 $used_volids->{$drive->{file
}} = 1 if $drive && $drive->{file
};
2368 &$cleanup_config($conf);
2370 &$cleanup_config($conf->{pending
}, 1);
2372 foreach my $snapname (keys %{$conf->{snapshots
}}) {
2373 die "internal error: snapshot name '$snapname' is forbidden" if lc($snapname) eq 'pending';
2374 &$cleanup_config($conf->{snapshots
}->{$snapname}, undef, $snapname);
2377 # remove 'unusedX' settings if we re-add a volume
2378 foreach my $key (keys %$conf) {
2379 my $value = $conf->{$key};
2380 if ($key =~ m/^unused/ && $used_volids->{$value}) {
2381 delete $conf->{$key};
2385 my $generate_raw_config = sub {
2386 my ($conf, $pending) = @_;
2390 # add description as comment to top of file
2391 if (defined(my $descr = $conf->{description
})) {
2393 foreach my $cl (split(/\n/, $descr)) {
2394 $raw .= '#' . PVE
::Tools
::encode_text
($cl) . "\n";
2397 $raw .= "#\n" if $pending;
2401 foreach my $key (sort keys %$conf) {
2402 next if $key =~ /^(digest|description|pending|snapshots)$/;
2403 $raw .= "$key: $conf->{$key}\n";
2408 my $raw = &$generate_raw_config($conf);
2410 if (scalar(keys %{$conf->{pending
}})){
2411 $raw .= "\n[PENDING]\n";
2412 $raw .= &$generate_raw_config($conf->{pending
}, 1);
2415 foreach my $snapname (sort keys %{$conf->{snapshots
}}) {
2416 $raw .= "\n[$snapname]\n";
2417 $raw .= &$generate_raw_config($conf->{snapshots
}->{$snapname});
2427 # we use static defaults from our JSON schema configuration
2428 foreach my $key (keys %$confdesc) {
2429 if (defined(my $default = $confdesc->{$key}->{default})) {
2430 $res->{$key} = $default;
2438 my $vmlist = PVE
::Cluster
::get_vmlist
();
2440 return $res if !$vmlist || !$vmlist->{ids
};
2441 my $ids = $vmlist->{ids
};
2442 my $nodename = nodename
();
2444 foreach my $vmid (keys %$ids) {
2445 my $d = $ids->{$vmid};
2446 next if !$d->{node
} || $d->{node
} ne $nodename;
2447 next if !$d->{type
} || $d->{type
} ne 'qemu';
2448 $res->{$vmid}->{exists} = 1;
2453 # test if VM uses local resources (to prevent migration)
2454 sub check_local_resources
{
2455 my ($conf, $noerr) = @_;
2459 push @loc_res, "hostusb" if $conf->{hostusb
}; # old syntax
2460 push @loc_res, "hostpci" if $conf->{hostpci
}; # old syntax
2462 push @loc_res, "ivshmem" if $conf->{ivshmem
};
2464 foreach my $k (keys %$conf) {
2465 next if $k =~ m/^usb/ && ($conf->{$k} =~ m/^spice(?![^,])/);
2466 # sockets are safe: they will recreated be on the target side post-migrate
2467 next if $k =~ m/^serial/ && ($conf->{$k} eq 'socket');
2468 push @loc_res, $k if $k =~ m/^(usb|hostpci|serial|parallel)\d+$/;
2471 die "VM uses local resources\n" if scalar @loc_res && !$noerr;
2476 # check if used storages are available on all nodes (use by migrate)
2477 sub check_storage_availability
{
2478 my ($storecfg, $conf, $node) = @_;
2480 PVE
::QemuConfig-
>foreach_volume($conf, sub {
2481 my ($ds, $drive) = @_;
2483 my $volid = $drive->{file
};
2486 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2489 # check if storage is available on both nodes
2490 my $scfg = PVE
::Storage
::storage_check_enabled
($storecfg, $sid);
2491 PVE
::Storage
::storage_check_enabled
($storecfg, $sid, $node);
2493 my ($vtype) = PVE
::Storage
::parse_volname
($storecfg, $volid);
2495 die "$volid: content type '$vtype' is not available on storage '$sid'\n"
2496 if !$scfg->{content
}->{$vtype};
2500 # list nodes where all VM images are available (used by has_feature API)
2502 my ($conf, $storecfg) = @_;
2504 my $nodelist = PVE
::Cluster
::get_nodelist
();
2505 my $nodehash = { map { $_ => 1 } @$nodelist };
2506 my $nodename = nodename
();
2508 PVE
::QemuConfig-
>foreach_volume($conf, sub {
2509 my ($ds, $drive) = @_;
2511 my $volid = $drive->{file
};
2514 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2516 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
2517 if ($scfg->{disable
}) {
2519 } elsif (my $avail = $scfg->{nodes
}) {
2520 foreach my $node (keys %$nodehash) {
2521 delete $nodehash->{$node} if !$avail->{$node};
2523 } elsif (!$scfg->{shared
}) {
2524 foreach my $node (keys %$nodehash) {
2525 delete $nodehash->{$node} if $node ne $nodename
2534 sub check_local_storage_availability
{
2535 my ($conf, $storecfg) = @_;
2537 my $nodelist = PVE
::Cluster
::get_nodelist
();
2538 my $nodehash = { map { $_ => {} } @$nodelist };
2540 PVE
::QemuConfig-
>foreach_volume($conf, sub {
2541 my ($ds, $drive) = @_;
2543 my $volid = $drive->{file
};
2546 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2548 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
2550 if ($scfg->{disable
}) {
2551 foreach my $node (keys %$nodehash) {
2552 $nodehash->{$node}->{unavailable_storages
}->{$storeid} = 1;
2554 } elsif (my $avail = $scfg->{nodes
}) {
2555 foreach my $node (keys %$nodehash) {
2556 if (!$avail->{$node}) {
2557 $nodehash->{$node}->{unavailable_storages
}->{$storeid} = 1;
2564 foreach my $node (values %$nodehash) {
2565 if (my $unavail = $node->{unavailable_storages
}) {
2566 $node->{unavailable_storages
} = [ sort keys %$unavail ];
2573 # Compat only, use assert_config_exists_on_node and vm_running_locally where possible
2575 my ($vmid, $nocheck, $node) = @_;
2577 PVE
::QemuConfig
::assert_config_exists_on_node
($vmid, $node) if !$nocheck;
2578 return PVE
::QemuServer
::Helpers
::vm_running_locally
($vmid);
2583 my $vzlist = config_list
();
2585 my $fd = IO
::Dir-
>new($PVE::QemuServer
::Helpers
::var_run_tmpdir
) || return $vzlist;
2587 while (defined(my $de = $fd->read)) {
2588 next if $de !~ m/^(\d+)\.pid$/;
2590 next if !defined($vzlist->{$vmid});
2591 if (my $pid = check_running
($vmid)) {
2592 $vzlist->{$vmid}->{pid
} = $pid;
2599 our $vmstatus_return_properties = {
2600 vmid
=> get_standard_option
('pve-vmid'),
2602 description
=> "Qemu process status.",
2604 enum
=> ['stopped', 'running'],
2607 description
=> "Maximum memory in bytes.",
2610 renderer
=> 'bytes',
2613 description
=> "Root disk size in bytes.",
2616 renderer
=> 'bytes',
2619 description
=> "VM name.",
2624 description
=> "Qemu QMP agent status.",
2629 description
=> "PID of running qemu process.",
2634 description
=> "Uptime.",
2637 renderer
=> 'duration',
2640 description
=> "Maximum usable CPUs.",
2645 description
=> "The current config lock, if any.",
2650 description
=> "The current configured tags, if any",
2654 'running-machine' => {
2655 description
=> "The currently running machine type (if running).",
2660 description
=> "The currently running QEMU version (if running).",
2666 my $last_proc_pid_stat;
2668 # get VM status information
2669 # This must be fast and should not block ($full == false)
2670 # We only query KVM using QMP if $full == true (this can be slow)
2672 my ($opt_vmid, $full) = @_;
2676 my $storecfg = PVE
::Storage
::config
();
2678 my $list = vzlist
();
2679 my $defaults = load_defaults
();
2681 my ($uptime) = PVE
::ProcFSTools
::read_proc_uptime
(1);
2683 my $cpucount = $cpuinfo->{cpus
} || 1;
2685 foreach my $vmid (keys %$list) {
2686 next if $opt_vmid && ($vmid ne $opt_vmid);
2688 my $conf = PVE
::QemuConfig-
>load_config($vmid);
2690 my $d = { vmid
=> int($vmid) };
2691 $d->{pid
} = int($list->{$vmid}->{pid
}) if $list->{$vmid}->{pid
};
2693 # fixme: better status?
2694 $d->{status
} = $list->{$vmid}->{pid
} ?
'running' : 'stopped';
2696 my $size = PVE
::QemuServer
::Drive
::bootdisk_size
($storecfg, $conf);
2697 if (defined($size)) {
2698 $d->{disk
} = 0; # no info available
2699 $d->{maxdisk
} = $size;
2705 $d->{cpus
} = ($conf->{sockets
} || $defaults->{sockets
})
2706 * ($conf->{cores
} || $defaults->{cores
});
2707 $d->{cpus
} = $cpucount if $d->{cpus
} > $cpucount;
2708 $d->{cpus
} = $conf->{vcpus
} if $conf->{vcpus
};
2710 $d->{name
} = $conf->{name
} || "VM $vmid";
2711 $d->{maxmem
} = $conf->{memory
} ?
$conf->{memory
}*(1024*1024)
2712 : $defaults->{memory
}*(1024*1024);
2714 if ($conf->{balloon
}) {
2715 $d->{balloon_min
} = $conf->{balloon
}*(1024*1024);
2716 $d->{shares
} = defined($conf->{shares
}) ?
$conf->{shares
}
2717 : $defaults->{shares
};
2728 $d->{diskwrite
} = 0;
2730 $d->{template
} = 1 if PVE
::QemuConfig-
>is_template($conf);
2732 $d->{serial
} = 1 if conf_has_serial
($conf);
2733 $d->{lock} = $conf->{lock} if $conf->{lock};
2734 $d->{tags
} = $conf->{tags
} if defined($conf->{tags
});
2739 my $netdev = PVE
::ProcFSTools
::read_proc_net_dev
();
2740 foreach my $dev (keys %$netdev) {
2741 next if $dev !~ m/^tap([1-9]\d*)i/;
2743 my $d = $res->{$vmid};
2746 $d->{netout
} += $netdev->{$dev}->{receive
};
2747 $d->{netin
} += $netdev->{$dev}->{transmit
};
2750 $d->{nics
}->{$dev}->{netout
} = int($netdev->{$dev}->{receive
});
2751 $d->{nics
}->{$dev}->{netin
} = int($netdev->{$dev}->{transmit
});
2756 my $ctime = gettimeofday
;
2758 foreach my $vmid (keys %$list) {
2760 my $d = $res->{$vmid};
2761 my $pid = $d->{pid
};
2764 my $pstat = PVE
::ProcFSTools
::read_proc_pid_stat
($pid);
2765 next if !$pstat; # not running
2767 my $used = $pstat->{utime} + $pstat->{stime
};
2769 $d->{uptime
} = int(($uptime - $pstat->{starttime
})/$cpuinfo->{user_hz
});
2771 if ($pstat->{vsize
}) {
2772 $d->{mem
} = int(($pstat->{rss
}/$pstat->{vsize
})*$d->{maxmem
});
2775 my $old = $last_proc_pid_stat->{$pid};
2777 $last_proc_pid_stat->{$pid} = {
2785 my $dtime = ($ctime - $old->{time}) * $cpucount * $cpuinfo->{user_hz
};
2787 if ($dtime > 1000) {
2788 my $dutime = $used - $old->{used
};
2790 $d->{cpu
} = (($dutime/$dtime)* $cpucount) / $d->{cpus
};
2791 $last_proc_pid_stat->{$pid} = {
2797 $d->{cpu
} = $old->{cpu
};
2801 return $res if !$full;
2803 my $qmpclient = PVE
::QMPClient-
>new();
2805 my $ballooncb = sub {
2806 my ($vmid, $resp) = @_;
2808 my $info = $resp->{'return'};
2809 return if !$info->{max_mem
};
2811 my $d = $res->{$vmid};
2813 # use memory assigned to VM
2814 $d->{maxmem
} = $info->{max_mem
};
2815 $d->{balloon
} = $info->{actual
};
2817 if (defined($info->{total_mem
}) && defined($info->{free_mem
})) {
2818 $d->{mem
} = $info->{total_mem
} - $info->{free_mem
};
2819 $d->{freemem
} = $info->{free_mem
};
2822 $d->{ballooninfo
} = $info;
2825 my $blockstatscb = sub {
2826 my ($vmid, $resp) = @_;
2827 my $data = $resp->{'return'} || [];
2828 my $totalrdbytes = 0;
2829 my $totalwrbytes = 0;
2831 for my $blockstat (@$data) {
2832 $totalrdbytes = $totalrdbytes + $blockstat->{stats
}->{rd_bytes
};
2833 $totalwrbytes = $totalwrbytes + $blockstat->{stats
}->{wr_bytes
};
2835 $blockstat->{device
} =~ s/drive-//;
2836 $res->{$vmid}->{blockstat
}->{$blockstat->{device
}} = $blockstat->{stats
};
2838 $res->{$vmid}->{diskread
} = $totalrdbytes;
2839 $res->{$vmid}->{diskwrite
} = $totalwrbytes;
2842 my $machinecb = sub {
2843 my ($vmid, $resp) = @_;
2844 my $data = $resp->{'return'} || [];
2846 $res->{$vmid}->{'running-machine'} =
2847 PVE
::QemuServer
::Machine
::current_from_query_machines
($data);
2850 my $versioncb = sub {
2851 my ($vmid, $resp) = @_;
2852 my $data = $resp->{'return'} // {};
2853 my $version = 'unknown';
2855 if (my $v = $data->{qemu
}) {
2856 $version = $v->{major
} . "." . $v->{minor
} . "." . $v->{micro
};
2859 $res->{$vmid}->{'running-qemu'} = $version;
2862 my $statuscb = sub {
2863 my ($vmid, $resp) = @_;
2865 $qmpclient->queue_cmd($vmid, $blockstatscb, 'query-blockstats');
2866 $qmpclient->queue_cmd($vmid, $machinecb, 'query-machines');
2867 $qmpclient->queue_cmd($vmid, $versioncb, 'query-version');
2868 # this fails if ballon driver is not loaded, so this must be
2869 # the last commnand (following command are aborted if this fails).
2870 $qmpclient->queue_cmd($vmid, $ballooncb, 'query-balloon');
2872 my $status = 'unknown';
2873 if (!defined($status = $resp->{'return'}->{status
})) {
2874 warn "unable to get VM status\n";
2878 $res->{$vmid}->{qmpstatus
} = $resp->{'return'}->{status
};
2881 foreach my $vmid (keys %$list) {
2882 next if $opt_vmid && ($vmid ne $opt_vmid);
2883 next if !$res->{$vmid}->{pid
}; # not running
2884 $qmpclient->queue_cmd($vmid, $statuscb, 'query-status');
2887 $qmpclient->queue_execute(undef, 2);
2889 foreach my $vmid (keys %$list) {
2890 next if $opt_vmid && ($vmid ne $opt_vmid);
2891 next if !$res->{$vmid}->{pid
}; #not running
2893 # we can't use the $qmpclient since it might have already aborted on
2894 # 'query-balloon', but this might also fail for older versions...
2895 my $qemu_support = eval { mon_cmd
($vmid, "query-proxmox-support") };
2896 $res->{$vmid}->{'proxmox-support'} = $qemu_support // {};
2899 foreach my $vmid (keys %$list) {
2900 next if $opt_vmid && ($vmid ne $opt_vmid);
2901 $res->{$vmid}->{qmpstatus
} = $res->{$vmid}->{status
} if !$res->{$vmid}->{qmpstatus
};
2907 sub conf_has_serial
{
2910 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
2911 if ($conf->{"serial$i"}) {
2919 sub conf_has_audio
{
2920 my ($conf, $id) = @_;
2923 my $audio = $conf->{"audio$id"};
2924 return if !defined($audio);
2926 my $audioproperties = parse_property_string
($audio_fmt, $audio);
2927 my $audiodriver = $audioproperties->{driver
} // 'spice';
2930 dev
=> $audioproperties->{device
},
2931 dev_id
=> "audiodev$id",
2932 backend
=> $audiodriver,
2933 backend_id
=> "$audiodriver-backend${id}",
2938 my ($audio, $audiopciaddr, $machine_version) = @_;
2942 my $id = $audio->{dev_id
};
2944 if (min_version
($machine_version, 4, 2)) {
2945 $audiodev = ",audiodev=$audio->{backend_id}";
2948 if ($audio->{dev
} eq 'AC97') {
2949 push @$devs, '-device', "AC97,id=${id}${audiopciaddr}$audiodev";
2950 } elsif ($audio->{dev
} =~ /intel\-hda$/) {
2951 push @$devs, '-device', "$audio->{dev},id=${id}${audiopciaddr}";
2952 push @$devs, '-device', "hda-micro,id=${id}-codec0,bus=${id}.0,cad=0$audiodev";
2953 push @$devs, '-device', "hda-duplex,id=${id}-codec1,bus=${id}.0,cad=1$audiodev";
2955 die "unkown audio device '$audio->{dev}', implement me!";
2958 push @$devs, '-audiodev', "$audio->{backend},id=$audio->{backend_id}";
2963 sub vga_conf_has_spice
{
2966 my $vgaconf = parse_vga
($vga);
2967 my $vgatype = $vgaconf->{type
};
2968 return 0 if !$vgatype || $vgatype !~ m/^qxl([234])?$/;
2975 return get_host_arch
() eq $arch;
2980 return $conf->{arch
} // get_host_arch
();
2983 my $default_machines = {
2988 sub get_installed_machine_version
{
2989 my ($kvmversion) = @_;
2990 $kvmversion = kvm_user_version
() if !defined($kvmversion);
2991 $kvmversion =~ m/^(\d+\.\d+)/;
2995 sub windows_get_pinned_machine_version
{
2996 my ($machine, $base_version, $kvmversion) = @_;
2998 my $pin_version = $base_version;
2999 if (!defined($base_version) ||
3000 !PVE
::QemuServer
::Machine
::can_run_pve_machine_version
($base_version, $kvmversion)
3002 $pin_version = get_installed_machine_version
($kvmversion);
3004 if (!$machine || $machine eq 'pc') {
3005 $machine = "pc-i440fx-$pin_version";
3006 } elsif ($machine eq 'q35') {
3007 $machine = "pc-q35-$pin_version";
3008 } elsif ($machine eq 'virt') {
3009 $machine = "virt-$pin_version";
3011 warn "unknown machine type '$machine', not touching that!\n";
3017 sub get_vm_machine
{
3018 my ($conf, $forcemachine, $arch, $add_pve_version, $kvmversion) = @_;
3020 my $machine = $forcemachine || $conf->{machine
};
3022 if (!$machine || $machine =~ m/^(?:pc|q35|virt)$/) {
3023 $kvmversion //= kvm_user_version
();
3024 # we must pin Windows VMs without a specific version to 5.1, as 5.2 fixed a bug in ACPI
3025 # layout which confuses windows quite a bit and may result in various regressions..
3026 # see: https://lists.gnu.org/archive/html/qemu-devel/2021-02/msg08484.html
3027 if (windows_version
($conf->{ostype
})) {
3028 $machine = windows_get_pinned_machine_version
($machine, '5.1', $kvmversion);
3031 $machine ||= $default_machines->{$arch};
3032 if ($add_pve_version) {
3033 my $pvever = PVE
::QemuServer
::Machine
::get_pve_version
($kvmversion);
3034 $machine .= "+pve$pvever";
3038 if ($add_pve_version && $machine !~ m/\+pve\d+?(?:\.pxe)?$/) {
3039 my $is_pxe = $machine =~ m/^(.*?)\.pxe$/;
3040 $machine = $1 if $is_pxe;
3042 # for version-pinned machines that do not include a pve-version (e.g.
3043 # pc-q35-4.1), we assume 0 to keep them stable in case we bump
3044 $machine .= '+pve0';
3046 $machine .= '.pxe' if $is_pxe;
3052 sub get_ovmf_files
($) {
3055 my $ovmf = $OVMF->{$arch}
3056 or die "no OVMF images known for architecture '$arch'\n";
3062 aarch64
=> '/usr/bin/qemu-system-aarch64',
3063 x86_64
=> '/usr/bin/qemu-system-x86_64',
3065 sub get_command_for_arch
($) {
3067 return '/usr/bin/kvm' if is_native
($arch);
3069 my $cmd = $Arch2Qemu->{$arch}
3070 or die "don't know how to emulate architecture '$arch'\n";
3074 # To use query_supported_cpu_flags and query_understood_cpu_flags to get flags
3075 # to use in a QEMU command line (-cpu element), first array_intersect the result
3076 # of query_supported_ with query_understood_. This is necessary because:
3078 # a) query_understood_ returns flags the host cannot use and
3079 # b) query_supported_ (rather the QMP call) doesn't actually return CPU
3080 # flags, but CPU settings - with most of them being flags. Those settings
3081 # (and some flags, curiously) cannot be specified as a "-cpu" argument.
3083 # query_supported_ needs to start up to 2 temporary VMs and is therefore rather
3084 # expensive. If you need the value returned from this, you can get it much
3085 # cheaper from pmxcfs using PVE::Cluster::get_node_kv('cpuflags-$accel') with
3086 # $accel being 'kvm' or 'tcg'.
3088 # pvestatd calls this function on startup and whenever the QEMU/KVM version
3089 # changes, automatically populating pmxcfs.
3091 # Returns: { kvm => [ flagX, flagY, ... ], tcg => [ flag1, flag2, ... ] }
3092 # since kvm and tcg machines support different flags
3094 sub query_supported_cpu_flags
{
3097 $arch //= get_host_arch
();
3098 my $default_machine = $default_machines->{$arch};
3102 # FIXME: Once this is merged, the code below should work for ARM as well:
3103 # https://lists.nongnu.org/archive/html/qemu-devel/2019-06/msg04947.html
3104 die "QEMU/KVM cannot detect CPU flags on ARM (aarch64)\n" if
3107 my $kvm_supported = defined(kvm_version
());
3108 my $qemu_cmd = get_command_for_arch
($arch);
3110 my $pidfile = PVE
::QemuServer
::Helpers
::pidfile_name
($fakevmid);
3112 # Start a temporary (frozen) VM with vmid -1 to allow sending a QMP command
3113 my $query_supported_run_qemu = sub {
3119 '-machine', $default_machine,
3121 '-chardev', "socket,id=qmp,path=/var/run/qemu-server/$fakevmid.qmp,server=on,wait=off",
3122 '-mon', 'chardev=qmp,mode=control',
3123 '-pidfile', $pidfile,
3128 push @$cmd, '-accel', 'tcg';
3131 my $rc = run_command
($cmd, noerr
=> 1, quiet
=> 0);
3132 die "QEMU flag querying VM exited with code " . $rc if $rc;
3135 my $cmd_result = mon_cmd
(
3137 'query-cpu-model-expansion',
3139 model
=> { name
=> 'host' }
3142 my $props = $cmd_result->{model
}->{props
};
3143 foreach my $prop (keys %$props) {
3144 next if $props->{$prop} ne '1';
3145 # QEMU returns some flags multiple times, with '_', '.' or '-'
3146 # (e.g. lahf_lm and lahf-lm; sse4.2, sse4-2 and sse4_2; ...).
3147 # We only keep those with underscores, to match /proc/cpuinfo
3148 $prop =~ s/\.|-/_/g;
3149 $flags->{$prop} = 1;
3154 # force stop with 10 sec timeout and 'nocheck'
3155 # always stop, even if QMP failed
3156 vm_stop
(undef, $fakevmid, 1, 1, 10, 0, 1);
3160 return [ sort keys %$flags ];
3163 # We need to query QEMU twice, since KVM and TCG have different supported flags
3164 PVE
::QemuConfig-
>lock_config($fakevmid, sub {
3165 $flags->{tcg
} = eval { $query_supported_run_qemu->(0) };
3166 warn "warning: failed querying supported tcg flags: $@\n" if $@;
3168 if ($kvm_supported) {
3169 $flags->{kvm
} = eval { $query_supported_run_qemu->(1) };
3170 warn "warning: failed querying supported kvm flags: $@\n" if $@;
3177 # Understood CPU flags are written to a file at 'pve-qemu' compile time
3178 my $understood_cpu_flag_dir = "/usr/share/kvm";
3179 sub query_understood_cpu_flags
{
3180 my $arch = get_host_arch
();
3181 my $filepath = "$understood_cpu_flag_dir/recognized-CPUID-flags-$arch";
3183 die "Cannot query understood QEMU CPU flags for architecture: $arch (file not found)\n"
3186 my $raw = file_get_contents
($filepath);
3187 $raw =~ s/^\s+|\s+$//g;
3188 my @flags = split(/\s+/, $raw);
3193 my sub get_cpuunits
{
3195 return $conf->{cpuunits
} // (PVE
::CGroup
::cgroup_mode
() == 2 ?
100 : 1024);
3197 sub config_to_command
{
3198 my ($storecfg, $vmid, $conf, $defaults, $forcemachine, $forcecpu,
3202 my $globalFlags = [];
3203 my $machineFlags = [];
3208 my $ostype = $conf->{ostype
};
3209 my $winversion = windows_version
($ostype);
3210 my $kvm = $conf->{kvm
};
3211 my $nodename = nodename
();
3213 my $arch = get_vm_arch
($conf);
3214 my $kvm_binary = get_command_for_arch
($arch);
3215 my $kvmver = kvm_user_version
($kvm_binary);
3217 if (!$kvmver || $kvmver !~ m/^(\d+)\.(\d+)/ || $1 < 3) {
3218 $kvmver //= "undefined";
3219 die "Detected old QEMU binary ('$kvmver', at least 3.0 is required)\n";
3222 my $add_pve_version = min_version
($kvmver, 4, 1);
3224 my $machine_type = get_vm_machine
($conf, $forcemachine, $arch, $add_pve_version);
3225 my $machine_version = extract_version
($machine_type, $kvmver);
3226 $kvm //= 1 if is_native
($arch);
3228 $machine_version =~ m/(\d+)\.(\d+)/;
3229 my ($machine_major, $machine_minor) = ($1, $2);
3231 if ($kvmver =~ m/^\d+\.\d+\.(\d+)/ && $1 >= 90) {
3232 warn "warning: Installed QEMU version ($kvmver) is a release candidate, ignoring version checks\n";
3233 } elsif (!min_version
($kvmver, $machine_major, $machine_minor)) {
3234 die "Installed QEMU version '$kvmver' is too old to run machine type '$machine_type',"
3235 ." please upgrade node '$nodename'\n"
3236 } elsif (!PVE
::QemuServer
::Machine
::can_run_pve_machine_version
($machine_version, $kvmver)) {
3237 my $max_pve_version = PVE
::QemuServer
::Machine
::get_pve_version
($machine_version);
3238 die "Installed qemu-server (max feature level for $machine_major.$machine_minor is"
3239 ." pve$max_pve_version) is too old to run machine type '$machine_type', please upgrade"
3240 ." node '$nodename'\n";
3243 # if a specific +pve version is required for a feature, use $version_guard
3244 # instead of min_version to allow machines to be run with the minimum
3246 my $required_pve_version = 0;
3247 my $version_guard = sub {
3248 my ($major, $minor, $pve) = @_;
3249 return 0 if !min_version
($machine_version, $major, $minor, $pve);
3250 my $max_pve = PVE
::QemuServer
::Machine
::get_pve_version
("$major.$minor");
3251 return 1 if min_version
($machine_version, $major, $minor, $max_pve+1);
3252 $required_pve_version = $pve if $pve && $pve > $required_pve_version;
3256 if ($kvm && !defined kvm_version
()) {
3257 die "KVM virtualisation configured, but not available. Either disable in VM configuration"
3258 ." or enable in BIOS.\n";
3261 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
3262 my $hotplug_features = parse_hotplug_features
(defined($conf->{hotplug
}) ?
$conf->{hotplug
} : '1');
3263 my $use_old_bios_files = undef;
3264 ($use_old_bios_files, $machine_type) = qemu_use_old_bios_files
($machine_type);
3266 my $cpuunits = get_cpuunits
($conf);
3268 push @$cmd, $kvm_binary;
3270 push @$cmd, '-id', $vmid;
3272 my $vmname = $conf->{name
} || "vm$vmid";
3274 push @$cmd, '-name', $vmname;
3276 push @$cmd, '-no-shutdown';
3280 my $qmpsocket = PVE
::QemuServer
::Helpers
::qmp_socket
($vmid);
3281 push @$cmd, '-chardev', "socket,id=qmp,path=$qmpsocket,server=on,wait=off";
3282 push @$cmd, '-mon', "chardev=qmp,mode=control";
3284 if (min_version
($machine_version, 2, 12)) {
3285 push @$cmd, '-chardev', "socket,id=qmp-event,path=/var/run/qmeventd.sock,reconnect=5";
3286 push @$cmd, '-mon', "chardev=qmp-event,mode=control";
3289 push @$cmd, '-pidfile' , PVE
::QemuServer
::Helpers
::pidfile_name
($vmid);
3291 push @$cmd, '-daemonize';
3293 if ($conf->{smbios1
}) {
3294 my $smbios_conf = parse_smbios1
($conf->{smbios1
});
3295 if ($smbios_conf->{base64
}) {
3296 # Do not pass base64 flag to qemu
3297 delete $smbios_conf->{base64
};
3298 my $smbios_string = "";
3299 foreach my $key (keys %$smbios_conf) {
3301 if ($key eq "uuid") {
3302 $value = $smbios_conf->{uuid
}
3304 $value = decode_base64
($smbios_conf->{$key});
3306 # qemu accepts any binary data, only commas need escaping by double comma
3308 $smbios_string .= "," . $key . "=" . $value if $value;
3310 push @$cmd, '-smbios', "type=1" . $smbios_string;
3312 push @$cmd, '-smbios', "type=1,$conf->{smbios1}";
3316 if ($conf->{bios
} && $conf->{bios
} eq 'ovmf') {
3317 my ($ovmf_code, $ovmf_vars) = get_ovmf_files
($arch);
3318 die "uefi base image '$ovmf_code' not found\n" if ! -f
$ovmf_code;
3320 my ($path, $format);
3321 my $read_only_str = '';
3322 if (my $efidisk = $conf->{efidisk0
}) {
3323 my $d = parse_drive
('efidisk0', $efidisk);
3324 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($d->{file
}, 1);
3325 $format = $d->{format
};
3327 $path = PVE
::Storage
::path
($storecfg, $d->{file
});
3328 if (!defined($format)) {
3329 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
3330 $format = qemu_img_format
($scfg, $volname);
3334 die "efidisk format must be specified\n"
3335 if !defined($format);
3338 $read_only_str = ',readonly=on' if drive_is_read_only
($conf, $d);
3340 warn "no efidisk configured! Using temporary efivars disk.\n";
3341 $path = "/tmp/$vmid-ovmf.fd";
3342 PVE
::Tools
::file_copy
($ovmf_vars, $path, -s
$ovmf_vars);
3348 if ($format eq 'raw' && $version_guard->(4, 1, 2)) {
3349 $size_str = ",size=" . (-s
$ovmf_vars);
3352 # SPI flash does lots of read-modify-write OPs, without writeback this gets really slow #3329
3354 if ($path =~ m/^rbd:/) {
3355 $cache = ',cache=writeback';
3356 $path .= ':rbd_cache_policy=writeback'; # avoid write-around, we *need* to cache writes too
3359 push @$cmd, '-drive', "if=pflash,unit=0,format=raw,readonly=on,file=$ovmf_code";
3360 push @$cmd, '-drive', "if=pflash,unit=1$cache,format=$format,id=drive-efidisk0$size_str,file=${path}${read_only_str}";
3365 # we use different pcie-port hardware for qemu >= 4.0 for passthrough
3366 if (min_version
($machine_version, 4, 0)) {
3367 push @$devices, '-readconfig', '/usr/share/qemu-server/pve-q35-4.0.cfg';
3369 push @$devices, '-readconfig', '/usr/share/qemu-server/pve-q35.cfg';
3373 if ($conf->{vmgenid
}) {
3374 push @$devices, '-device', 'vmgenid,guid='.$conf->{vmgenid
};
3377 # add usb controllers
3378 my @usbcontrollers = PVE
::QemuServer
::USB
::get_usb_controllers
(
3379 $conf, $bridges, $arch, $machine_type, $usbdesc->{format
}, $MAX_USB_DEVICES);
3380 push @$devices, @usbcontrollers if @usbcontrollers;
3381 my $vga = parse_vga
($conf->{vga
});
3383 my $qxlnum = vga_conf_has_spice
($conf->{vga
});
3384 $vga->{type
} = 'qxl' if $qxlnum;
3386 if (!$vga->{type
}) {
3387 if ($arch eq 'aarch64') {
3388 $vga->{type
} = 'virtio';
3389 } elsif (min_version
($machine_version, 2, 9)) {
3390 $vga->{type
} = (!$winversion || $winversion >= 6) ?
'std' : 'cirrus';
3392 $vga->{type
} = ($winversion >= 6) ?
'std' : 'cirrus';
3396 # enable absolute mouse coordinates (needed by vnc)
3398 if (defined($conf->{tablet
})) {
3399 $tablet = $conf->{tablet
};
3401 $tablet = $defaults->{tablet
};
3402 $tablet = 0 if $qxlnum; # disable for spice because it is not needed
3403 $tablet = 0 if $vga->{type
} =~ m/^serial\d+$/; # disable if we use serial terminal (no vga card)
3407 push @$devices, '-device', print_tabletdevice_full
($conf, $arch) if $tablet;
3408 my $kbd = print_keyboarddevice_full
($conf, $arch);
3409 push @$devices, '-device', $kbd if defined($kbd);
3412 my $bootorder = device_bootorder
($conf);
3414 # host pci device passthrough
3415 my ($kvm_off, $gpu_passthrough, $legacy_igd) = PVE
::QemuServer
::PCI
::print_hostpci_devices
(
3416 $vmid, $conf, $devices, $vga, $winversion, $q35, $bridges, $arch, $machine_type, $bootorder);
3419 my $usb_dev_features = {};
3420 $usb_dev_features->{spice_usb3
} = 1 if min_version
($machine_version, 4, 0);
3422 my @usbdevices = PVE
::QemuServer
::USB
::get_usb_devices
(
3423 $conf, $usbdesc->{format
}, $MAX_USB_DEVICES, $usb_dev_features, $bootorder);
3424 push @$devices, @usbdevices if @usbdevices;
3427 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
3428 if (my $path = $conf->{"serial$i"}) {
3429 if ($path eq 'socket') {
3430 my $socket = "/var/run/qemu-server/${vmid}.serial$i";
3431 push @$devices, '-chardev', "socket,id=serial$i,path=$socket,server=on,wait=off";
3432 # On aarch64, serial0 is the UART device. Qemu only allows
3433 # connecting UART devices via the '-serial' command line, as
3434 # the device has a fixed slot on the hardware...
3435 if ($arch eq 'aarch64' && $i == 0) {
3436 push @$devices, '-serial', "chardev:serial$i";
3438 push @$devices, '-device', "isa-serial,chardev=serial$i";
3441 die "no such serial device\n" if ! -c
$path;
3442 push @$devices, '-chardev', "tty,id=serial$i,path=$path";
3443 push @$devices, '-device', "isa-serial,chardev=serial$i";
3449 for (my $i = 0; $i < $MAX_PARALLEL_PORTS; $i++) {
3450 if (my $path = $conf->{"parallel$i"}) {
3451 die "no such parallel device\n" if ! -c
$path;
3452 my $devtype = $path =~ m!^/dev/usb/lp! ?
'tty' : 'parport';
3453 push @$devices, '-chardev', "$devtype,id=parallel$i,path=$path";
3454 push @$devices, '-device', "isa-parallel,chardev=parallel$i";
3458 if (min_version
($machine_version, 4, 0) && (my $audio = conf_has_audio
($conf))) {
3459 my $audiopciaddr = print_pci_addr
("audio0", $bridges, $arch, $machine_type);
3460 my $audio_devs = audio_devs
($audio, $audiopciaddr, $machine_version);
3461 push @$devices, @$audio_devs;
3465 $sockets = $conf->{smp
} if $conf->{smp
}; # old style - no longer iused
3466 $sockets = $conf->{sockets
} if $conf->{sockets
};
3468 my $cores = $conf->{cores
} || 1;
3470 my $maxcpus = $sockets * $cores;
3472 my $vcpus = $conf->{vcpus
} ?
$conf->{vcpus
} : $maxcpus;
3474 my $allowed_vcpus = $cpuinfo->{cpus
};
3476 die "MAX $allowed_vcpus vcpus allowed per VM on this node\n"
3477 if ($allowed_vcpus < $maxcpus);
3479 if($hotplug_features->{cpu
} && min_version
($machine_version, 2, 7)) {
3481 push @$cmd, '-smp', "1,sockets=$sockets,cores=$cores,maxcpus=$maxcpus";
3482 for (my $i = 2; $i <= $vcpus; $i++) {
3483 my $cpustr = print_cpu_device
($conf,$i);
3484 push @$cmd, '-device', $cpustr;
3489 push @$cmd, '-smp', "$vcpus,sockets=$sockets,cores=$cores,maxcpus=$maxcpus";
3491 push @$cmd, '-nodefaults';
3493 push @$cmd, '-boot', "menu=on,strict=on,reboot-timeout=1000,splash=/usr/share/qemu-server/bootsplash.jpg";
3495 push @$cmd, '-no-acpi' if defined($conf->{acpi
}) && $conf->{acpi
} == 0;
3497 push @$cmd, '-no-reboot' if defined($conf->{reboot
}) && $conf->{reboot
} == 0;
3499 if ($vga->{type
} && $vga->{type
} !~ m/^serial\d+$/ && $vga->{type
} ne 'none'){
3500 push @$devices, '-device', print_vga_device
(
3501 $conf, $vga, $arch, $machine_version, $machine_type, undef, $qxlnum, $bridges);
3502 my $socket = PVE
::QemuServer
::Helpers
::vnc_socket
($vmid);
3503 push @$cmd, '-vnc', "unix:$socket,password=on";
3505 push @$cmd, '-vga', 'none' if $vga->{type
} eq 'none';
3506 push @$cmd, '-nographic';
3510 my $tdf = defined($conf->{tdf
}) ?
$conf->{tdf
} : $defaults->{tdf
};
3511 my $useLocaltime = $conf->{localtime};
3513 if ($winversion >= 5) { # windows
3514 $useLocaltime = 1 if !defined($conf->{localtime});
3516 # use time drift fix when acpi is enabled
3517 if (!(defined($conf->{acpi
}) && $conf->{acpi
} == 0)) {
3518 $tdf = 1 if !defined($conf->{tdf
});
3522 if ($winversion >= 6) {
3523 push @$globalFlags, 'kvm-pit.lost_tick_policy=discard';
3524 push @$cmd, '-no-hpet';
3527 push @$rtcFlags, 'driftfix=slew' if $tdf;
3529 if ($conf->{startdate
} && $conf->{startdate
} ne 'now') {
3530 push @$rtcFlags, "base=$conf->{startdate}";
3531 } elsif ($useLocaltime) {
3532 push @$rtcFlags, 'base=localtime';
3536 push @$cmd, '-cpu', $forcecpu;
3538 push @$cmd, get_cpu_options
($conf, $arch, $kvm, $kvm_off, $machine_version, $winversion, $gpu_passthrough);
3541 PVE
::QemuServer
::Memory
::config
($conf, $vmid, $sockets, $cores, $defaults, $hotplug_features, $cmd);
3543 push @$cmd, '-S' if $conf->{freeze
};
3545 push @$cmd, '-k', $conf->{keyboard
} if defined($conf->{keyboard
});
3547 my $guest_agent = parse_guest_agent
($conf);
3549 if ($guest_agent->{enabled
}) {
3550 my $qgasocket = PVE
::QemuServer
::Helpers
::qmp_socket
($vmid, 1);
3551 push @$devices, '-chardev', "socket,path=$qgasocket,server=on,wait=off,id=qga0";
3553 if (!$guest_agent->{type
} || $guest_agent->{type
} eq 'virtio') {
3554 my $pciaddr = print_pci_addr
("qga0", $bridges, $arch, $machine_type);
3555 push @$devices, '-device', "virtio-serial,id=qga0$pciaddr";
3556 push @$devices, '-device', 'virtserialport,chardev=qga0,name=org.qemu.guest_agent.0';
3557 } elsif ($guest_agent->{type
} eq 'isa') {
3558 push @$devices, '-device', "isa-serial,chardev=qga0";
3562 my $rng = $conf->{rng0
} ? parse_rng
($conf->{rng0
}) : undef;
3563 if ($rng && $version_guard->(4, 1, 2)) {
3564 check_rng_source
($rng->{source
});
3566 my $max_bytes = $rng->{max_bytes
} // $rng_fmt->{max_bytes
}->{default};
3567 my $period = $rng->{period
} // $rng_fmt->{period
}->{default};
3568 my $limiter_str = "";
3570 $limiter_str = ",max-bytes=$max_bytes,period=$period";
3573 my $rng_addr = print_pci_addr
("rng0", $bridges, $arch, $machine_type);
3574 push @$devices, '-object', "rng-random,filename=$rng->{source},id=rng0";
3575 push @$devices, '-device', "virtio-rng-pci,rng=rng0$limiter_str$rng_addr";
3583 for (my $i = 1; $i < $qxlnum; $i++){
3584 push @$devices, '-device', print_vga_device
(
3585 $conf, $vga, $arch, $machine_version, $machine_type, $i, $qxlnum, $bridges);
3588 # assume other OS works like Linux
3589 my ($ram, $vram) = ("134217728", "67108864");
3590 if ($vga->{memory
}) {
3591 $ram = PVE
::Tools
::convert_size
($qxlnum*4*$vga->{memory
}, 'mb' => 'b');
3592 $vram = PVE
::Tools
::convert_size
($qxlnum*2*$vga->{memory
}, 'mb' => 'b');
3594 push @$cmd, '-global', "qxl-vga.ram_size=$ram";
3595 push @$cmd, '-global', "qxl-vga.vram_size=$vram";
3599 my $pciaddr = print_pci_addr
("spice", $bridges, $arch, $machine_type);
3601 my $pfamily = PVE
::Tools
::get_host_address_family
($nodename);
3602 my @nodeaddrs = PVE
::Tools
::getaddrinfo_all
('localhost', family
=> $pfamily);
3603 die "failed to get an ip address of type $pfamily for 'localhost'\n" if !@nodeaddrs;
3605 push @$devices, '-device', "virtio-serial,id=spice$pciaddr";
3606 push @$devices, '-chardev', "spicevmc,id=vdagent,name=vdagent";
3607 push @$devices, '-device', "virtserialport,chardev=vdagent,name=com.redhat.spice.0";
3609 my $localhost = PVE
::Network
::addr_to_ip
($nodeaddrs[0]->{addr
});
3610 $spice_port = PVE
::Tools
::next_spice_port
($pfamily, $localhost);
3612 my $spice_enhancement_str = $conf->{spice_enhancements
} // '';
3613 my $spice_enhancement = parse_property_string
($spice_enhancements_fmt, $spice_enhancement_str);
3614 if ($spice_enhancement->{foldersharing
}) {
3615 push @$devices, '-chardev', "spiceport,id=foldershare,name=org.spice-space.webdav.0";
3616 push @$devices, '-device', "virtserialport,chardev=foldershare,name=org.spice-space.webdav.0";
3619 my $spice_opts = "tls-port=${spice_port},addr=$localhost,tls-ciphers=HIGH,seamless-migration=on";
3620 $spice_opts .= ",streaming-video=$spice_enhancement->{videostreaming}"
3621 if $spice_enhancement->{videostreaming
};
3623 push @$devices, '-spice', "$spice_opts";
3626 # enable balloon by default, unless explicitly disabled
3627 if (!defined($conf->{balloon
}) || $conf->{balloon
}) {
3628 $pciaddr = print_pci_addr
("balloon0", $bridges, $arch, $machine_type);
3629 push @$devices, '-device', "virtio-balloon-pci,id=balloon0$pciaddr";
3632 if ($conf->{watchdog
}) {
3633 my $wdopts = parse_watchdog
($conf->{watchdog
});
3634 $pciaddr = print_pci_addr
("watchdog", $bridges, $arch, $machine_type);
3635 my $watchdog = $wdopts->{model
} || 'i6300esb';
3636 push @$devices, '-device', "$watchdog$pciaddr";
3637 push @$devices, '-watchdog-action', $wdopts->{action
} if $wdopts->{action
};
3641 my $scsicontroller = {};
3642 my $ahcicontroller = {};
3643 my $scsihw = defined($conf->{scsihw
}) ?
$conf->{scsihw
} : $defaults->{scsihw
};
3645 # Add iscsi initiator name if available
3646 if (my $initiator = get_initiator_name
()) {
3647 push @$devices, '-iscsi', "initiator-name=$initiator";
3650 PVE
::QemuConfig-
>foreach_volume($conf, sub {
3651 my ($ds, $drive) = @_;
3653 if (PVE
::Storage
::parse_volume_id
($drive->{file
}, 1)) {
3654 check_volume_storage_type
($storecfg, $drive->{file
});
3655 push @$vollist, $drive->{file
};
3658 # ignore efidisk here, already added in bios/fw handling code above
3659 return if $drive->{interface
} eq 'efidisk';
3661 $use_virtio = 1 if $ds =~ m/^virtio/;
3663 $drive->{bootindex
} = $bootorder->{$ds} if $bootorder->{$ds};
3665 if ($drive->{interface
} eq 'virtio'){
3666 push @$cmd, '-object', "iothread,id=iothread-$ds" if $drive->{iothread
};
3669 if ($drive->{interface
} eq 'scsi') {
3671 my ($maxdev, $controller, $controller_prefix) = scsihw_infos
($conf, $drive);
3673 die "scsi$drive->{index}: machine version 4.1~pve2 or higher is required to use more than 14 SCSI disks\n"
3674 if $drive->{index} > 13 && !&$version_guard(4, 1, 2);
3676 $pciaddr = print_pci_addr
("$controller_prefix$controller", $bridges, $arch, $machine_type);
3677 my $scsihw_type = $scsihw =~ m/^virtio-scsi-single/ ?
"virtio-scsi-pci" : $scsihw;
3680 if($conf->{scsihw
} && $conf->{scsihw
} eq "virtio-scsi-single" && $drive->{iothread
}){
3681 $iothread .= ",iothread=iothread-$controller_prefix$controller";
3682 push @$cmd, '-object', "iothread,id=iothread-$controller_prefix$controller";
3683 } elsif ($drive->{iothread
}) {
3684 warn "iothread is only valid with virtio disk or virtio-scsi-single controller, ignoring\n";
3688 if($conf->{scsihw
} && $conf->{scsihw
} eq "virtio-scsi-single" && $drive->{queues
}){
3689 $queues = ",num_queues=$drive->{queues}";
3692 push @$devices, '-device', "$scsihw_type,id=$controller_prefix$controller$pciaddr$iothread$queues"
3693 if !$scsicontroller->{$controller};
3694 $scsicontroller->{$controller}=1;
3697 if ($drive->{interface
} eq 'sata') {
3698 my $controller = int($drive->{index} / $PVE::QemuServer
::Drive
::MAX_SATA_DISKS
);
3699 $pciaddr = print_pci_addr
("ahci$controller", $bridges, $arch, $machine_type);
3700 push @$devices, '-device', "ahci,id=ahci$controller,multifunction=on$pciaddr"
3701 if !$ahcicontroller->{$controller};
3702 $ahcicontroller->{$controller}=1;
3705 my $pbs_conf = $pbs_backing->{$ds};
3706 my $pbs_name = undef;
3708 $pbs_name = "drive-$ds-pbs";
3709 push @$devices, '-blockdev', print_pbs_blockdev
($pbs_conf, $pbs_name);
3712 my $drive_cmd = print_drive_commandline_full
(
3713 $storecfg, $vmid, $drive, $pbs_name, min_version
($kvmver, 6, 0));
3715 # extra protection for templates, but SATA and IDE don't support it..
3716 $drive_cmd .= ',readonly=on' if drive_is_read_only
($conf, $drive);
3718 push @$devices, '-drive',$drive_cmd;
3719 push @$devices, '-device', print_drivedevice_full
(
3720 $storecfg, $conf, $vmid, $drive, $bridges, $arch, $machine_type);
3723 for (my $i = 0; $i < $MAX_NETS; $i++) {
3724 my $netname = "net$i";
3726 next if !$conf->{$netname};
3727 my $d = parse_net
($conf->{$netname});
3730 $use_virtio = 1 if $d->{model
} eq 'virtio';
3732 $d->{bootindex
} = $bootorder->{$netname} if $bootorder->{$netname};
3734 my $netdevfull = print_netdev_full
($vmid, $conf, $arch, $d, $netname);
3735 push @$devices, '-netdev', $netdevfull;
3737 my $netdevicefull = print_netdevice_full
(
3738 $vmid, $conf, $d, $netname, $bridges, $use_old_bios_files, $arch, $machine_type);
3740 push @$devices, '-device', $netdevicefull;
3743 if ($conf->{ivshmem
}) {
3744 my $ivshmem = parse_property_string
($ivshmem_fmt, $conf->{ivshmem
});
3748 $bus = print_pcie_addr
("ivshmem");
3750 $bus = print_pci_addr
("ivshmem", $bridges, $arch, $machine_type);
3753 my $ivshmem_name = $ivshmem->{name
} // $vmid;
3754 my $path = '/dev/shm/pve-shm-' . $ivshmem_name;
3756 push @$devices, '-device', "ivshmem-plain,memdev=ivshmem$bus,";
3757 push @$devices, '-object', "memory-backend-file,id=ivshmem,share=on,mem-path=$path"
3758 .",size=$ivshmem->{size}M";
3761 # pci.4 is nested in pci.1
3762 $bridges->{1} = 1 if $bridges->{4};
3766 if (min_version
($machine_version, 2, 3)) {
3771 $bridges->{3} = 1 if $scsihw =~ m/^virtio-scsi-single/;
3775 for my $k (sort {$b cmp $a} keys %$bridges) {
3776 next if $q35 && $k < 4; # q35.cfg already includes bridges up to 3
3779 if ($k == 2 && $legacy_igd) {
3782 $pciaddr = print_pci_addr
("pci.$k_name", undef, $arch, $machine_type);
3784 my $devstr = "pci-bridge,id=pci.$k,chassis_nr=$k$pciaddr";
3786 # add after -readconfig pve-q35.cfg
3787 splice @$devices, 2, 0, '-device', $devstr;
3789 unshift @$devices, '-device', $devstr if $k > 0;
3794 push @$machineFlags, 'accel=tcg';
3797 my $machine_type_min = $machine_type;
3798 if ($add_pve_version) {
3799 $machine_type_min =~ s/\+pve\d+$//;
3800 $machine_type_min .= "+pve$required_pve_version";
3802 push @$machineFlags, "type=${machine_type_min}";
3804 push @$cmd, @$devices;
3805 push @$cmd, '-rtc', join(',', @$rtcFlags) if scalar(@$rtcFlags);
3806 push @$cmd, '-machine', join(',', @$machineFlags) if scalar(@$machineFlags);
3807 push @$cmd, '-global', join(',', @$globalFlags) if scalar(@$globalFlags);
3809 if (my $vmstate = $conf->{vmstate
}) {
3810 my $statepath = PVE
::Storage
::path
($storecfg, $vmstate);
3811 push @$vollist, $vmstate;
3812 push @$cmd, '-loadstate', $statepath;
3813 print "activating and using '$vmstate' as vmstate\n";
3816 if (PVE
::QemuConfig-
>is_template($conf)) {
3817 # needed to workaround base volumes being read-only
3818 push @$cmd, '-snapshot';
3822 if ($conf->{args
}) {
3823 my $aa = PVE
::Tools
::split_args
($conf->{args
});
3827 return wantarray ?
($cmd, $vollist, $spice_port) : $cmd;
3830 sub check_rng_source
{
3833 # mostly relevant for /dev/hwrng, but doesn't hurt to check others too
3834 die "cannot create VirtIO RNG device: source file '$source' doesn't exist\n"
3837 my $rng_current = '/sys/devices/virtual/misc/hw_random/rng_current';
3838 if ($source eq '/dev/hwrng' && file_read_firstline
($rng_current) eq 'none') {
3839 # Needs to abort, otherwise QEMU crashes on first rng access. Note that rng_current cannot
3840 # be changed to 'none' manually, so once the VM is past this point, it's no longer an issue.
3841 die "Cannot start VM with passed-through RNG device: '/dev/hwrng' exists, but"
3842 ." '$rng_current' is set to 'none'. Ensure that a compatible hardware-RNG is attached"
3850 my $res = mon_cmd
($vmid, 'query-spice');
3852 return $res->{'tls-port'} || $res->{'port'} || die "no spice port\n";
3855 sub vm_devices_list
{
3858 my $res = mon_cmd
($vmid, 'query-pci');
3859 my $devices_to_check = [];
3861 foreach my $pcibus (@$res) {
3862 push @$devices_to_check, @{$pcibus->{devices
}},
3865 while (@$devices_to_check) {
3867 for my $d (@$devices_to_check) {
3868 $devices->{$d->{'qdev_id'}} = 1 if $d->{'qdev_id'};
3869 next if !$d->{'pci_bridge'};
3871 $devices->{$d->{'qdev_id'}} += scalar(@{$d->{'pci_bridge'}->{devices
}});
3872 push @$to_check, @{$d->{'pci_bridge'}->{devices
}};
3874 $devices_to_check = $to_check;
3877 my $resblock = mon_cmd
($vmid, 'query-block');
3878 foreach my $block (@$resblock) {
3879 if($block->{device
} =~ m/^drive-(\S+)/){
3884 my $resmice = mon_cmd
($vmid, 'query-mice');
3885 foreach my $mice (@$resmice) {
3886 if ($mice->{name
} eq 'QEMU HID Tablet') {
3887 $devices->{tablet
} = 1;
3892 # for usb devices there is no query-usb
3893 # but we can iterate over the entries in
3894 # qom-list path=/machine/peripheral
3895 my $resperipheral = mon_cmd
($vmid, 'qom-list', path
=> '/machine/peripheral');
3896 foreach my $per (@$resperipheral) {
3897 if ($per->{name
} =~ m/^usb\d+$/) {
3898 $devices->{$per->{name
}} = 1;
3906 my ($storecfg, $conf, $vmid, $deviceid, $device, $arch, $machine_type) = @_;
3908 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
3910 my $devices_list = vm_devices_list
($vmid);
3911 return 1 if defined($devices_list->{$deviceid});
3913 # add PCI bridge if we need it for the device
3914 qemu_add_pci_bridge
($storecfg, $conf, $vmid, $deviceid, $arch, $machine_type);
3916 if ($deviceid eq 'tablet') {
3918 qemu_deviceadd
($vmid, print_tabletdevice_full
($conf, $arch));
3920 } elsif ($deviceid eq 'keyboard') {
3922 qemu_deviceadd
($vmid, print_keyboarddevice_full
($conf, $arch));
3924 } elsif ($deviceid =~ m/^usb(\d+)$/) {
3926 die "usb hotplug currently not reliable\n";
3927 # since we can't reliably hot unplug all added usb devices and usb
3928 # passthrough breaks live migration we disable usb hotplugging for now
3929 #qemu_deviceadd($vmid, PVE::QemuServer::USB::print_usbdevice_full($conf, $deviceid, $device));
3931 } elsif ($deviceid =~ m/^(virtio)(\d+)$/) {
3933 qemu_iothread_add
($vmid, $deviceid, $device);
3935 qemu_driveadd
($storecfg, $vmid, $device);
3936 my $devicefull = print_drivedevice_full
($storecfg, $conf, $vmid, $device, undef, $arch, $machine_type);
3938 qemu_deviceadd
($vmid, $devicefull);
3939 eval { qemu_deviceaddverify
($vmid, $deviceid); };
3941 eval { qemu_drivedel
($vmid, $deviceid); };
3946 } elsif ($deviceid =~ m/^(virtioscsi|scsihw)(\d+)$/) {
3949 my $scsihw = defined($conf->{scsihw
}) ?
$conf->{scsihw
} : "lsi";
3950 my $pciaddr = print_pci_addr
($deviceid, undef, $arch, $machine_type);
3951 my $scsihw_type = $scsihw eq 'virtio-scsi-single' ?
"virtio-scsi-pci" : $scsihw;
3953 my $devicefull = "$scsihw_type,id=$deviceid$pciaddr";
3955 if($deviceid =~ m/^virtioscsi(\d+)$/ && $device->{iothread
}) {
3956 qemu_iothread_add
($vmid, $deviceid, $device);
3957 $devicefull .= ",iothread=iothread-$deviceid";
3960 if($deviceid =~ m/^virtioscsi(\d+)$/ && $device->{queues
}) {
3961 $devicefull .= ",num_queues=$device->{queues}";
3964 qemu_deviceadd
($vmid, $devicefull);
3965 qemu_deviceaddverify
($vmid, $deviceid);
3967 } elsif ($deviceid =~ m/^(scsi)(\d+)$/) {
3969 qemu_findorcreatescsihw
($storecfg,$conf, $vmid, $device, $arch, $machine_type);
3970 qemu_driveadd
($storecfg, $vmid, $device);
3972 my $devicefull = print_drivedevice_full
($storecfg, $conf, $vmid, $device, undef, $arch, $machine_type);
3973 eval { qemu_deviceadd
($vmid, $devicefull); };
3975 eval { qemu_drivedel
($vmid, $deviceid); };
3980 } elsif ($deviceid =~ m/^(net)(\d+)$/) {
3982 return if !qemu_netdevadd
($vmid, $conf, $arch, $device, $deviceid);
3984 my $machine_type = PVE
::QemuServer
::Machine
::qemu_machine_pxe
($vmid, $conf);
3985 my $use_old_bios_files = undef;
3986 ($use_old_bios_files, $machine_type) = qemu_use_old_bios_files
($machine_type);
3988 my $netdevicefull = print_netdevice_full
(
3989 $vmid, $conf, $device, $deviceid, undef, $use_old_bios_files, $arch, $machine_type);
3990 qemu_deviceadd
($vmid, $netdevicefull);
3992 qemu_deviceaddverify
($vmid, $deviceid);
3993 qemu_set_link_status
($vmid, $deviceid, !$device->{link_down
});
3996 eval { qemu_netdevdel
($vmid, $deviceid); };
4001 } elsif (!$q35 && $deviceid =~ m/^(pci\.)(\d+)$/) {
4004 my $pciaddr = print_pci_addr
($deviceid, undef, $arch, $machine_type);
4005 my $devicefull = "pci-bridge,id=pci.$bridgeid,chassis_nr=$bridgeid$pciaddr";
4007 qemu_deviceadd
($vmid, $devicefull);
4008 qemu_deviceaddverify
($vmid, $deviceid);
4011 die "can't hotplug device '$deviceid'\n";
4017 # fixme: this should raise exceptions on error!
4018 sub vm_deviceunplug
{
4019 my ($vmid, $conf, $deviceid) = @_;
4021 my $devices_list = vm_devices_list
($vmid);
4022 return 1 if !defined($devices_list->{$deviceid});
4024 my $bootdisks = PVE
::QemuServer
::Drive
::get_bootdisks
($conf);
4025 die "can't unplug bootdisk '$deviceid'\n" if grep {$_ eq $deviceid} @$bootdisks;
4027 if ($deviceid eq 'tablet' || $deviceid eq 'keyboard') {
4029 qemu_devicedel
($vmid, $deviceid);
4031 } elsif ($deviceid =~ m/^usb\d+$/) {
4033 die "usb hotplug currently not reliable\n";
4034 # when unplugging usb devices this way, there may be remaining usb
4035 # controllers/hubs so we disable it for now
4036 #qemu_devicedel($vmid, $deviceid);
4037 #qemu_devicedelverify($vmid, $deviceid);
4039 } elsif ($deviceid =~ m/^(virtio)(\d+)$/) {
4041 qemu_devicedel
($vmid, $deviceid);
4042 qemu_devicedelverify
($vmid, $deviceid);
4043 qemu_drivedel
($vmid, $deviceid);
4044 qemu_iothread_del
($conf, $vmid, $deviceid);
4046 } elsif ($deviceid =~ m/^(virtioscsi|scsihw)(\d+)$/) {
4048 qemu_devicedel
($vmid, $deviceid);
4049 qemu_devicedelverify
($vmid, $deviceid);
4050 qemu_iothread_del
($conf, $vmid, $deviceid);
4052 } elsif ($deviceid =~ m/^(scsi)(\d+)$/) {
4054 qemu_devicedel
($vmid, $deviceid);
4055 qemu_drivedel
($vmid, $deviceid);
4056 qemu_deletescsihw
($conf, $vmid, $deviceid);
4058 } elsif ($deviceid =~ m/^(net)(\d+)$/) {
4060 qemu_devicedel
($vmid, $deviceid);
4061 qemu_devicedelverify
($vmid, $deviceid);
4062 qemu_netdevdel
($vmid, $deviceid);
4065 die "can't unplug device '$deviceid'\n";
4071 sub qemu_deviceadd
{
4072 my ($vmid, $devicefull) = @_;
4074 $devicefull = "driver=".$devicefull;
4075 my %options = split(/[=,]/, $devicefull);
4077 mon_cmd
($vmid, "device_add" , %options);
4080 sub qemu_devicedel
{
4081 my ($vmid, $deviceid) = @_;
4083 my $ret = mon_cmd
($vmid, "device_del", id
=> $deviceid);
4086 sub qemu_iothread_add
{
4087 my($vmid, $deviceid, $device) = @_;
4089 if ($device->{iothread
}) {
4090 my $iothreads = vm_iothreads_list
($vmid);
4091 qemu_objectadd
($vmid, "iothread-$deviceid", "iothread") if !$iothreads->{"iothread-$deviceid"};
4095 sub qemu_iothread_del
{
4096 my($conf, $vmid, $deviceid) = @_;
4098 my $confid = $deviceid;
4099 if ($deviceid =~ m/^(?:virtioscsi|scsihw)(\d+)$/) {
4100 $confid = 'scsi' . $1;
4102 my $device = parse_drive
($confid, $conf->{$confid});
4103 if ($device->{iothread
}) {
4104 my $iothreads = vm_iothreads_list
($vmid);
4105 qemu_objectdel
($vmid, "iothread-$deviceid") if $iothreads->{"iothread-$deviceid"};
4109 sub qemu_objectadd
{
4110 my($vmid, $objectid, $qomtype) = @_;
4112 mon_cmd
($vmid, "object-add", id
=> $objectid, "qom-type" => $qomtype);
4117 sub qemu_objectdel
{
4118 my($vmid, $objectid) = @_;
4120 mon_cmd
($vmid, "object-del", id
=> $objectid);
4126 my ($storecfg, $vmid, $device) = @_;
4128 my $kvmver = get_running_qemu_version
($vmid);
4129 my $io_uring = min_version
($kvmver, 6, 0);
4130 my $drive = print_drive_commandline_full
($storecfg, $vmid, $device, undef, $io_uring);
4131 $drive =~ s/\\/\\\\/g;
4132 my $ret = PVE
::QemuServer
::Monitor
::hmp_cmd
($vmid, "drive_add auto \"$drive\"");
4134 # If the command succeeds qemu prints: "OK
"
4135 return 1 if $ret =~ m/OK/s;
4137 die "adding drive failed
: $ret\n";
4141 my($vmid, $deviceid) = @_;
4143 my $ret = PVE::QemuServer::Monitor::hmp_cmd($vmid, "drive_del drive-
$deviceid");
4146 return 1 if $ret eq "";
4148 # NB: device not found errors mean the drive was auto-deleted and we ignore the error
4149 return 1 if $ret =~ m/Device \'.*?\' not found/s;
4151 die "deleting drive
$deviceid failed
: $ret\n";
4154 sub qemu_deviceaddverify {
4155 my ($vmid, $deviceid) = @_;
4157 for (my $i = 0; $i <= 5; $i++) {
4158 my $devices_list = vm_devices_list($vmid);
4159 return 1 if defined($devices_list->{$deviceid});
4163 die "error on hotplug device
'$deviceid'\n";
4167 sub qemu_devicedelverify {
4168 my ($vmid, $deviceid) = @_;
4170 # need to verify that the device is correctly removed as device_del
4171 # is async and empty return is not reliable
4173 for (my $i = 0; $i <= 5; $i++) {
4174 my $devices_list = vm_devices_list($vmid);
4175 return 1 if !defined($devices_list->{$deviceid});
4179 die "error on hot-unplugging device
'$deviceid'\n";
4182 sub qemu_findorcreatescsihw {
4183 my ($storecfg, $conf, $vmid, $device, $arch, $machine_type) = @_;
4185 my ($maxdev, $controller, $controller_prefix) = scsihw_infos($conf, $device);
4187 my $scsihwid="$controller_prefix$controller";
4188 my $devices_list = vm_devices_list($vmid);
4190 if(!defined($devices_list->{$scsihwid})) {
4191 vm_deviceplug($storecfg, $conf, $vmid, $scsihwid, $device, $arch, $machine_type);
4197 sub qemu_deletescsihw {
4198 my ($conf, $vmid, $opt) = @_;
4200 my $device = parse_drive($opt, $conf->{$opt});
4202 if ($conf->{scsihw} && ($conf->{scsihw} eq 'virtio-scsi-single')) {
4203 vm_deviceunplug($vmid, $conf, "virtioscsi
$device->{index}");
4207 my ($maxdev, $controller, $controller_prefix) = scsihw_infos($conf, $device);
4209 my $devices_list = vm_devices_list($vmid);
4210 foreach my $opt (keys %{$devices_list}) {
4211 if (is_valid_drivename($opt)) {
4212 my $drive = parse_drive($opt, $conf->{$opt});
4213 if($drive->{interface} eq 'scsi' && $drive->{index} < (($maxdev-1)*($controller+1))) {
4219 my $scsihwid="scsihw
$controller";
4221 vm_deviceunplug($vmid, $conf, $scsihwid);
4226 sub qemu_add_pci_bridge {
4227 my ($storecfg, $conf, $vmid, $device, $arch, $machine_type) = @_;
4233 print_pci_addr($device, $bridges, $arch, $machine_type);
4235 while (my ($k, $v) = each %$bridges) {
4238 return 1 if !defined($bridgeid) || $bridgeid < 1;
4240 my $bridge = "pci
.$bridgeid";
4241 my $devices_list = vm_devices_list($vmid);
4243 if (!defined($devices_list->{$bridge})) {
4244 vm_deviceplug($storecfg, $conf, $vmid, $bridge, $arch, $machine_type);
4250 sub qemu_set_link_status {
4251 my ($vmid, $device, $up) = @_;
4253 mon_cmd($vmid, "set_link
", name => $device,
4254 up => $up ? JSON::true : JSON::false);
4257 sub qemu_netdevadd {
4258 my ($vmid, $conf, $arch, $device, $deviceid) = @_;
4260 my $netdev = print_netdev_full($vmid, $conf, $arch, $device, $deviceid, 1);
4261 my %options = split(/[=,]/, $netdev);
4263 if (defined(my $vhost = $options{vhost})) {
4264 $options{vhost} = JSON::boolean(PVE::JSONSchema::parse_boolean($vhost));
4267 if (defined(my $queues = $options{queues})) {
4268 $options{queues} = $queues + 0;
4271 mon_cmd($vmid, "netdev_add
", %options);
4275 sub qemu_netdevdel {
4276 my ($vmid, $deviceid) = @_;
4278 mon_cmd($vmid, "netdev_del
", id => $deviceid);
4281 sub qemu_usb_hotplug {
4282 my ($storecfg, $conf, $vmid, $deviceid, $device, $arch, $machine_type) = @_;
4286 # remove the old one first
4287 vm_deviceunplug($vmid, $conf, $deviceid);
4289 # check if xhci controller is necessary and available
4290 if ($device->{usb3}) {
4292 my $devicelist = vm_devices_list($vmid);
4294 if (!$devicelist->{xhci}) {
4295 my $pciaddr = print_pci_addr("xhci
", undef, $arch, $machine_type);
4296 qemu_deviceadd($vmid, "nec-usb-xhci
,id
=xhci
$pciaddr");
4299 my $d = parse_usb_device($device->{host});
4300 $d->{usb3} = $device->{usb3};
4303 vm_deviceplug($storecfg, $conf, $vmid, $deviceid, $d, $arch, $machine_type);
4306 sub qemu_cpu_hotplug {
4307 my ($vmid, $conf, $vcpus) = @_;
4309 my $machine_type = PVE::QemuServer::Machine::get_current_qemu_machine($vmid);
4312 $sockets = $conf->{smp} if $conf->{smp}; # old style - no longer iused
4313 $sockets = $conf->{sockets} if $conf->{sockets};
4314 my $cores = $conf->{cores} || 1;
4315 my $maxcpus = $sockets * $cores;
4317 $vcpus = $maxcpus if !$vcpus;
4319 die "you can
't add more vcpus than maxcpus\n"
4320 if $vcpus > $maxcpus;
4322 my $currentvcpus = $conf->{vcpus} || $maxcpus;
4324 if ($vcpus < $currentvcpus) {
4326 if (PVE::QemuServer::Machine::machine_version($machine_type, 2, 7)) {
4328 for (my $i = $currentvcpus; $i > $vcpus; $i--) {
4329 qemu_devicedel($vmid, "cpu$i");
4331 my $currentrunningvcpus = undef;
4333 $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4334 last if scalar(@{$currentrunningvcpus}) == $i-1;
4335 raise_param_exc({ vcpus => "error unplugging cpu$i" }) if $retry > 5;
4339 #update conf after each succesfull cpu unplug
4340 $conf->{vcpus} = scalar(@{$currentrunningvcpus});
4341 PVE::QemuConfig->write_config($vmid, $conf);
4344 die "cpu hot-unplugging requires qemu version 2.7 or higher\n";
4350 my $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4351 die "vcpus in running vm does not match its configuration\n"
4352 if scalar(@{$currentrunningvcpus}) != $currentvcpus;
4354 if (PVE::QemuServer::Machine::machine_version($machine_type, 2, 7)) {
4356 for (my $i = $currentvcpus+1; $i <= $vcpus; $i++) {
4357 my $cpustr = print_cpu_device($conf, $i);
4358 qemu_deviceadd($vmid, $cpustr);
4361 my $currentrunningvcpus = undef;
4363 $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4364 last if scalar(@{$currentrunningvcpus}) == $i;
4365 raise_param_exc({ vcpus => "error hotplugging cpu$i" }) if $retry > 10;
4369 #update conf after each succesfull cpu hotplug
4370 $conf->{vcpus} = scalar(@{$currentrunningvcpus});
4371 PVE::QemuConfig->write_config($vmid, $conf);
4375 for (my $i = $currentvcpus; $i < $vcpus; $i++) {
4376 mon_cmd($vmid, "cpu-add", id => int($i));
4381 sub qemu_block_set_io_throttle {
4382 my ($vmid, $deviceid,
4383 $bps, $bps_rd, $bps_wr, $iops, $iops_rd, $iops_wr,
4384 $bps_max, $bps_rd_max, $bps_wr_max, $iops_max, $iops_rd_max, $iops_wr_max,
4385 $bps_max_length, $bps_rd_max_length, $bps_wr_max_length,
4386 $iops_max_length, $iops_rd_max_length, $iops_wr_max_length) = @_;
4388 return if !check_running($vmid) ;
4390 mon_cmd($vmid, "block_set_io_throttle", device => $deviceid,
4392 bps_rd => int($bps_rd),
4393 bps_wr => int($bps_wr),
4395 iops_rd => int($iops_rd),
4396 iops_wr => int($iops_wr),
4397 bps_max => int($bps_max),
4398 bps_rd_max => int($bps_rd_max),
4399 bps_wr_max => int($bps_wr_max),
4400 iops_max => int($iops_max),
4401 iops_rd_max => int($iops_rd_max),
4402 iops_wr_max => int($iops_wr_max),
4403 bps_max_length => int($bps_max_length),
4404 bps_rd_max_length => int($bps_rd_max_length),
4405 bps_wr_max_length => int($bps_wr_max_length),
4406 iops_max_length => int($iops_max_length),
4407 iops_rd_max_length => int($iops_rd_max_length),
4408 iops_wr_max_length => int($iops_wr_max_length),
4413 sub qemu_block_resize {
4414 my ($vmid, $deviceid, $storecfg, $volid, $size) = @_;
4416 my $running = check_running($vmid);
4418 $size = 0 if !PVE::Storage::volume_resize($storecfg, $volid, $size, $running);
4420 return if !$running;
4422 my $padding = (1024 - $size % 1024) % 1024;
4423 $size = $size + $padding;
4428 device => $deviceid,
4434 sub qemu_volume_snapshot {
4435 my ($vmid, $deviceid, $storecfg, $volid, $snap) = @_;
4437 my $running = check_running($vmid);
4439 if ($running && do_snapshots_with_qemu($storecfg, $volid)){
4440 mon_cmd($vmid, 'blockdev-snapshot-internal-sync
', device => $deviceid, name => $snap);
4442 PVE::Storage::volume_snapshot($storecfg, $volid, $snap);
4446 sub qemu_volume_snapshot_delete {
4447 my ($vmid, $deviceid, $storecfg, $volid, $snap) = @_;
4449 my $running = check_running($vmid);
4454 my $conf = PVE::QemuConfig->load_config($vmid);
4455 PVE::QemuConfig->foreach_volume($conf, sub {
4456 my ($ds, $drive) = @_;
4457 $running = 1 if $drive->{file} eq $volid;
4461 if ($running && do_snapshots_with_qemu($storecfg, $volid)){
4462 mon_cmd($vmid, 'blockdev-snapshot-delete-internal-sync
', device => $deviceid, name => $snap);
4464 PVE::Storage::volume_snapshot_delete($storecfg, $volid, $snap, $running);
4468 sub set_migration_caps {
4469 my ($vmid, $savevm) = @_;
4471 my $qemu_support = eval { mon_cmd($vmid, "query-proxmox-support") };
4473 my $bitmap_prop = $savevm ? 'pbs-dirty-bitmap-savevm
' : 'pbs-dirty-bitmap-migration
';
4474 my $dirty_bitmaps = $qemu_support->{$bitmap_prop} ? 1 : 0;
4479 "auto-converge" => 1,
4481 "x-rdma-pin-all" => 0,
4484 "dirty-bitmaps" => $dirty_bitmaps,
4487 my $supported_capabilities = mon_cmd($vmid, "query-migrate-capabilities");
4489 for my $supported_capability (@$supported_capabilities) {
4491 capability => $supported_capability->{capability},
4492 state => $enabled_cap->{$supported_capability->{capability}} ? JSON::true : JSON::false,
4496 mon_cmd($vmid, "migrate-set-capabilities", capabilities => $cap_ref);
4500 my ($conf, $func, @param) = @_;
4504 my $test_volid = sub {
4505 my ($key, $drive, $snapname) = @_;
4507 my $volid = $drive->{file};
4510 $volhash->{$volid}->{cdrom} //= 1;
4511 $volhash->{$volid}->{cdrom} = 0 if !drive_is_cdrom($drive);
4513 my $replicate = $drive->{replicate} // 1;
4514 $volhash->{$volid}->{replicate} //= 0;
4515 $volhash->{$volid}->{replicate} = 1 if $replicate;
4517 $volhash->{$volid}->{shared} //= 0;
4518 $volhash->{$volid}->{shared} = 1 if $drive->{shared};
4520 $volhash->{$volid}->{referenced_in_config} //= 0;
4521 $volhash->{$volid}->{referenced_in_config} = 1 if !defined($snapname);
4523 $volhash->{$volid}->{referenced_in_snapshot}->{$snapname} = 1
4524 if defined($snapname);
4526 my $size = $drive->{size};
4527 $volhash->{$volid}->{size} //= $size if $size;
4529 $volhash->{$volid}->{is_vmstate} //= 0;
4530 $volhash->{$volid}->{is_vmstate} = 1 if $key eq 'vmstate
';
4532 $volhash->{$volid}->{is_unused} //= 0;
4533 $volhash->{$volid}->{is_unused} = 1 if $key =~ /^unused\d+$/;
4535 $volhash->{$volid}->{drivename} = $key if is_valid_drivename($key);
4538 my $include_opts = {
4539 extra_keys => ['vmstate
'],
4540 include_unused => 1,
4543 PVE::QemuConfig->foreach_volume_full($conf, $include_opts, $test_volid);
4544 foreach my $snapname (keys %{$conf->{snapshots}}) {
4545 my $snap = $conf->{snapshots}->{$snapname};
4546 PVE::QemuConfig->foreach_volume_full($snap, $include_opts, $test_volid, $snapname);
4549 foreach my $volid (keys %$volhash) {
4550 &$func($volid, $volhash->{$volid}, @param);
4554 my $fast_plug_option = {
4562 'vmstatestorage
' => 1,
4567 # hotplug changes in [PENDING]
4568 # $selection hash can be used to only apply specified options, for
4569 # example: { cores => 1 } (only apply changed 'cores
')
4570 # $errors ref is used to return error messages
4571 sub vmconfig_hotplug_pending {
4572 my ($vmid, $conf, $storecfg, $selection, $errors) = @_;
4574 my $defaults = load_defaults();
4575 my $arch = get_vm_arch($conf);
4576 my $machine_type = get_vm_machine($conf, undef, $arch);
4578 # commit values which do not have any impact on running VM first
4579 # Note: those option cannot raise errors, we we do not care about
4580 # $selection and always apply them.
4582 my $add_error = sub {
4583 my ($opt, $msg) = @_;
4584 $errors->{$opt} = "hotplug problem - $msg";
4588 foreach my $opt (keys %{$conf->{pending}}) { # add/change
4589 if ($fast_plug_option->{$opt}) {
4590 $conf->{$opt} = $conf->{pending}->{$opt};
4591 delete $conf->{pending}->{$opt};
4597 PVE::QemuConfig->write_config($vmid, $conf);
4600 my $hotplug_features = parse_hotplug_features(defined($conf->{hotplug}) ? $conf->{hotplug} : '1');
4602 my $cgroup = PVE::QemuServer::CGroup->new($vmid);
4603 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4604 foreach my $opt (sort keys %$pending_delete_hash) {
4605 next if $selection && !$selection->{$opt};
4606 my $force = $pending_delete_hash->{$opt}->{force};
4608 if ($opt eq 'hotplug
') {
4609 die "skip\n" if ($conf->{hotplug} =~ /memory/);
4610 } elsif ($opt eq 'tablet
') {
4611 die "skip\n" if !$hotplug_features->{usb};
4612 if ($defaults->{tablet}) {
4613 vm_deviceplug($storecfg, $conf, $vmid, 'tablet
', $arch, $machine_type);
4614 vm_deviceplug($storecfg, $conf, $vmid, 'keyboard
', $arch, $machine_type)
4615 if $arch eq 'aarch64
';
4617 vm_deviceunplug($vmid, $conf, 'tablet
');
4618 vm_deviceunplug($vmid, $conf, 'keyboard
') if $arch eq 'aarch64
';
4620 } elsif ($opt =~ m/^usb\d+/) {
4622 # since we cannot reliably hot unplug usb devices we are disabling it
4623 #die "skip\n" if !$hotplug_features->{usb} || $conf->{$opt} =~ m/spice/i;
4624 #vm_deviceunplug($vmid, $conf, $opt);
4625 } elsif ($opt eq 'vcpus
') {
4626 die "skip\n" if !$hotplug_features->{cpu};
4627 qemu_cpu_hotplug($vmid, $conf, undef);
4628 } elsif ($opt eq 'balloon
') {
4629 # enable balloon device is not hotpluggable
4630 die "skip\n" if defined($conf->{balloon}) && $conf->{balloon} == 0;
4631 # here we reset the ballooning value to memory
4632 my $balloon = $conf->{memory} || $defaults->{memory};
4633 mon_cmd($vmid, "balloon", value => $balloon*1024*1024);
4634 } elsif ($fast_plug_option->{$opt}) {
4636 } elsif ($opt =~ m/^net(\d+)$/) {
4637 die "skip\n" if !$hotplug_features->{network};
4638 vm_deviceunplug($vmid, $conf, $opt);
4639 } elsif (is_valid_drivename($opt)) {
4640 die "skip\n" if !$hotplug_features->{disk} || $opt =~ m/(ide|sata)(\d+)/;
4641 vm_deviceunplug($vmid, $conf, $opt);
4642 vmconfig_delete_or_detach_drive($vmid, $storecfg, $conf, $opt, $force);
4643 } elsif ($opt =~ m/^memory$/) {
4644 die "skip\n" if !$hotplug_features->{memory};
4645 PVE::QemuServer::Memory::qemu_memory_hotplug($vmid, $conf, $defaults, $opt);
4646 } elsif ($opt eq 'cpuunits
') {
4647 $cgroup->change_cpu_shares(undef, 1024);
4648 } elsif ($opt eq 'cpulimit
') {
4649 $cgroup->change_cpu_quota(-1, 100000);
4655 &$add_error($opt, $err) if $err ne "skip\n";
4657 delete $conf->{$opt};
4658 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4662 my ($apply_pending_cloudinit, $apply_pending_cloudinit_done);
4663 $apply_pending_cloudinit = sub {
4664 return if $apply_pending_cloudinit_done; # once is enough
4665 $apply_pending_cloudinit_done = 1; # once is enough
4667 my ($key, $value) = @_;
4669 my @cloudinit_opts = keys %$confdesc_cloudinit;
4670 foreach my $opt (keys %{$conf->{pending}}) {
4671 next if !grep { $_ eq $opt } @cloudinit_opts;
4672 $conf->{$opt} = delete $conf->{pending}->{$opt};
4675 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4676 foreach my $opt (sort keys %$pending_delete_hash) {
4677 next if !grep { $_ eq $opt } @cloudinit_opts;
4678 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4679 delete $conf->{$opt};
4682 my $new_conf = { %$conf };
4683 $new_conf->{$key} = $value;
4684 PVE::QemuServer::Cloudinit::generate_cloudinitconfig($new_conf, $vmid);
4687 foreach my $opt (keys %{$conf->{pending}}) {
4688 next if $selection && !$selection->{$opt};
4689 my $value = $conf->{pending}->{$opt};
4691 if ($opt eq 'hotplug
') {
4692 die "skip\n" if ($value =~ /memory/) || ($value !~ /memory/ && $conf->{hotplug} =~ /memory/);
4693 } elsif ($opt eq 'tablet
') {
4694 die "skip\n" if !$hotplug_features->{usb};
4696 vm_deviceplug($storecfg, $conf, $vmid, 'tablet
', $arch, $machine_type);
4697 vm_deviceplug($storecfg, $conf, $vmid, 'keyboard
', $arch, $machine_type)
4698 if $arch eq 'aarch64
';
4699 } elsif ($value == 0) {
4700 vm_deviceunplug($vmid, $conf, 'tablet
');
4701 vm_deviceunplug($vmid, $conf, 'keyboard
') if $arch eq 'aarch64
';
4703 } elsif ($opt =~ m/^usb\d+$/) {
4705 # since we cannot reliably hot unplug usb devices we disable it for now
4706 #die "skip\n" if !$hotplug_features->{usb} || $value =~ m/spice/i;
4707 #my $d = eval { parse_property_string($usbdesc->{format}, $value) };
4708 #die "skip\n" if !$d;
4709 #qemu_usb_hotplug($storecfg, $conf, $vmid, $opt, $d, $arch, $machine_type);
4710 } elsif ($opt eq 'vcpus
') {
4711 die "skip\n" if !$hotplug_features->{cpu};
4712 qemu_cpu_hotplug($vmid, $conf, $value);
4713 } elsif ($opt eq 'balloon
') {
4714 # enable/disable balloning device is not hotpluggable
4715 my $old_balloon_enabled = !!(!defined($conf->{balloon}) || $conf->{balloon});
4716 my $new_balloon_enabled = !!(!defined($conf->{pending}->{balloon}) || $conf->{pending}->{balloon});
4717 die "skip\n" if $old_balloon_enabled != $new_balloon_enabled;
4719 # allow manual ballooning if shares is set to zero
4720 if ((defined($conf->{shares}) && ($conf->{shares} == 0))) {
4721 my $balloon = $conf->{pending}->{balloon} || $conf->{memory} || $defaults->{memory};
4722 mon_cmd($vmid, "balloon", value => $balloon*1024*1024);
4724 } elsif ($opt =~ m/^net(\d+)$/) {
4725 # some changes can be done without hotplug
4726 vmconfig_update_net($storecfg, $conf, $hotplug_features->{network},
4727 $vmid, $opt, $value, $arch, $machine_type);
4728 } elsif (is_valid_drivename($opt)) {
4729 die "skip\n" if $opt eq 'efidisk0
';
4730 # some changes can be done without hotplug
4731 my $drive = parse_drive($opt, $value);
4732 if (drive_is_cloudinit($drive)) {
4733 &$apply_pending_cloudinit($opt, $value);
4735 vmconfig_update_disk($storecfg, $conf, $hotplug_features->{disk},
4736 $vmid, $opt, $value, $arch, $machine_type);
4737 } elsif ($opt =~ m/^memory$/) { #dimms
4738 die "skip\n" if !$hotplug_features->{memory};
4739 $value = PVE::QemuServer::Memory::qemu_memory_hotplug($vmid, $conf, $defaults, $opt, $value);
4740 } elsif ($opt eq 'cpuunits
') {
4741 $cgroup->change_cpu_shares($conf->{pending}->{$opt}, 1024);
4742 } elsif ($opt eq 'cpulimit
') {
4743 my $cpulimit = $conf->{pending}->{$opt} == 0 ? -1 : int($conf->{pending}->{$opt} * 100000);
4744 $cgroup->change_cpu_quota($cpulimit, 100000);
4746 die "skip\n"; # skip non-hot-pluggable options
4750 &$add_error($opt, $err) if $err ne "skip\n";
4752 $conf->{$opt} = $value;
4753 delete $conf->{pending}->{$opt};
4757 PVE::QemuConfig->write_config($vmid, $conf);
4760 sub try_deallocate_drive {
4761 my ($storecfg, $vmid, $conf, $key, $drive, $rpcenv, $authuser, $force) = @_;
4763 if (($force || $key =~ /^unused/) && !drive_is_cdrom($drive, 1)) {
4764 my $volid = $drive->{file};
4765 if (vm_is_volid_owner($storecfg, $vmid, $volid)) {
4766 my $sid = PVE::Storage::parse_volume_id($volid);
4767 $rpcenv->check($authuser, "/storage/$sid", ['Datastore
.AllocateSpace
']);
4769 # check if the disk is really unused
4770 die "unable to delete '$volid' - volume is still in use (snapshot?)\n"
4771 if PVE::QemuServer::Drive::is_volume_in_use($storecfg, $conf, $key, $volid);
4772 PVE::Storage::vdisk_free($storecfg, $volid);
4775 # If vm is not owner of this disk remove from config
4783 sub vmconfig_delete_or_detach_drive {
4784 my ($vmid, $storecfg, $conf, $opt, $force) = @_;
4786 my $drive = parse_drive($opt, $conf->{$opt});
4788 my $rpcenv = PVE::RPCEnvironment::get();
4789 my $authuser = $rpcenv->get_user();
4792 $rpcenv->check_vm_perm($authuser, $vmid, undef, ['VM
.Config
.Disk
']);
4793 try_deallocate_drive($storecfg, $vmid, $conf, $opt, $drive, $rpcenv, $authuser, $force);
4795 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $drive);
4801 sub vmconfig_apply_pending {
4802 my ($vmid, $conf, $storecfg, $errors) = @_;
4804 my $add_apply_error = sub {
4805 my ($opt, $msg) = @_;
4806 my $err_msg = "unable to apply pending change $opt : $msg";
4807 $errors->{$opt} = $err_msg;
4813 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4814 foreach my $opt (sort keys %$pending_delete_hash) {
4815 my $force = $pending_delete_hash->{$opt}->{force};
4817 if ($opt =~ m/^unused/) {
4818 die "internal error";
4819 } elsif (defined($conf->{$opt}) && is_valid_drivename($opt)) {
4820 vmconfig_delete_or_detach_drive($vmid, $storecfg, $conf, $opt, $force);
4824 $add_apply_error->($opt, $err);
4826 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4827 delete $conf->{$opt};
4831 PVE::QemuConfig->cleanup_pending($conf);
4833 foreach my $opt (keys %{$conf->{pending}}) { # add/change
4834 next if $opt eq 'delete'; # just to be sure
4836 if (defined($conf->{$opt}) && is_valid_drivename($opt)) {
4837 vmconfig_register_unused_drive($storecfg, $vmid, $conf, parse_drive($opt, $conf->{$opt}))
4841 $add_apply_error->($opt, $err);
4843 $conf->{$opt} = delete $conf->{pending}->{$opt};
4847 # write all changes at once to avoid unnecessary i/o
4848 PVE::QemuConfig->write_config($vmid, $conf);
4851 sub vmconfig_update_net {
4852 my ($storecfg, $conf, $hotplug, $vmid, $opt, $value, $arch, $machine_type) = @_;
4854 my $newnet = parse_net($value);
4856 if ($conf->{$opt}) {
4857 my $oldnet = parse_net($conf->{$opt});
4859 if (safe_string_ne($oldnet->{model}, $newnet->{model}) ||
4860 safe_string_ne($oldnet->{macaddr}, $newnet->{macaddr}) ||
4861 safe_num_ne($oldnet->{queues}, $newnet->{queues}) ||
4862 !($newnet->{bridge} && $oldnet->{bridge})) { # bridge/nat mode change
4864 # for non online change, we try to hot-unplug
4865 die "skip\n" if !$hotplug;
4866 vm_deviceunplug($vmid, $conf, $opt);
4869 die "internal error" if $opt !~ m/net(\d+)/;
4870 my $iface = "tap${vmid}i$1";
4872 if (safe_string_ne($oldnet->{bridge}, $newnet->{bridge}) ||
4873 safe_num_ne($oldnet->{tag}, $newnet->{tag}) ||
4874 safe_string_ne($oldnet->{trunks}, $newnet->{trunks}) ||
4875 safe_num_ne($oldnet->{firewall}, $newnet->{firewall})) {
4876 PVE::Network::tap_unplug($iface);
4879 PVE::Network::SDN::Zones::tap_plug($iface, $newnet->{bridge}, $newnet->{tag}, $newnet->{firewall}, $newnet->{trunks}, $newnet->{rate});
4881 PVE::Network::tap_plug($iface, $newnet->{bridge}, $newnet->{tag}, $newnet->{firewall}, $newnet->{trunks}, $newnet->{rate});
4883 } elsif (safe_num_ne($oldnet->{rate}, $newnet->{rate})) {
4884 # Rate can be applied on its own but any change above needs to
4885 # include the rate in tap_plug since OVS resets everything.
4886 PVE::Network::tap_rate_limit($iface, $newnet->{rate});
4889 if (safe_string_ne($oldnet->{link_down}, $newnet->{link_down})) {
4890 qemu_set_link_status($vmid, $opt, !$newnet->{link_down});
4898 vm_deviceplug($storecfg, $conf, $vmid, $opt, $newnet, $arch, $machine_type);
4904 sub vmconfig_update_disk {
4905 my ($storecfg, $conf, $hotplug, $vmid, $opt, $value, $arch, $machine_type) = @_;
4907 my $drive = parse_drive($opt, $value);
4909 if ($conf->{$opt} && (my $old_drive = parse_drive($opt, $conf->{$opt}))) {
4910 my $media = $drive->{media} || 'disk
';
4911 my $oldmedia = $old_drive->{media} || 'disk
';
4912 die "unable to change media type\n" if $media ne $oldmedia;
4914 if (!drive_is_cdrom($old_drive)) {
4916 if ($drive->{file} ne $old_drive->{file}) {
4918 die "skip\n" if !$hotplug;
4920 # unplug and register as unused
4921 vm_deviceunplug($vmid, $conf, $opt);
4922 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $old_drive)
4925 # update existing disk
4927 # skip non hotpluggable value
4928 if (safe_string_ne($drive->{discard}, $old_drive->{discard}) ||
4929 safe_string_ne($drive->{iothread}, $old_drive->{iothread}) ||
4930 safe_string_ne($drive->{queues}, $old_drive->{queues}) ||
4931 safe_string_ne($drive->{cache}, $old_drive->{cache}) ||
4932 safe_string_ne($drive->{ssd}, $old_drive->{ssd})) {
4937 if (safe_num_ne($drive->{mbps}, $old_drive->{mbps}) ||
4938 safe_num_ne($drive->{mbps_rd}, $old_drive->{mbps_rd}) ||
4939 safe_num_ne($drive->{mbps_wr}, $old_drive->{mbps_wr}) ||
4940 safe_num_ne($drive->{iops}, $old_drive->{iops}) ||
4941 safe_num_ne($drive->{iops_rd}, $old_drive->{iops_rd}) ||
4942 safe_num_ne($drive->{iops_wr}, $old_drive->{iops_wr}) ||
4943 safe_num_ne($drive->{mbps_max}, $old_drive->{mbps_max}) ||
4944 safe_num_ne($drive->{mbps_rd_max}, $old_drive->{mbps_rd_max}) ||
4945 safe_num_ne($drive->{mbps_wr_max}, $old_drive->{mbps_wr_max}) ||
4946 safe_num_ne($drive->{iops_max}, $old_drive->{iops_max}) ||
4947 safe_num_ne($drive->{iops_rd_max}, $old_drive->{iops_rd_max}) ||
4948 safe_num_ne($drive->{iops_wr_max}, $old_drive->{iops_wr_max}) ||
4949 safe_num_ne($drive->{bps_max_length}, $old_drive->{bps_max_length}) ||
4950 safe_num_ne($drive->{bps_rd_max_length}, $old_drive->{bps_rd_max_length}) ||
4951 safe_num_ne($drive->{bps_wr_max_length}, $old_drive->{bps_wr_max_length}) ||
4952 safe_num_ne($drive->{iops_max_length}, $old_drive->{iops_max_length}) ||
4953 safe_num_ne($drive->{iops_rd_max_length}, $old_drive->{iops_rd_max_length}) ||
4954 safe_num_ne($drive->{iops_wr_max_length}, $old_drive->{iops_wr_max_length})) {
4956 qemu_block_set_io_throttle(
4958 ($drive->{mbps} || 0)*1024*1024,
4959 ($drive->{mbps_rd} || 0)*1024*1024,
4960 ($drive->{mbps_wr} || 0)*1024*1024,
4961 $drive->{iops} || 0,
4962 $drive->{iops_rd} || 0,
4963 $drive->{iops_wr} || 0,
4964 ($drive->{mbps_max} || 0)*1024*1024,
4965 ($drive->{mbps_rd_max} || 0)*1024*1024,
4966 ($drive->{mbps_wr_max} || 0)*1024*1024,
4967 $drive->{iops_max} || 0,
4968 $drive->{iops_rd_max} || 0,
4969 $drive->{iops_wr_max} || 0,
4970 $drive->{bps_max_length} || 1,
4971 $drive->{bps_rd_max_length} || 1,
4972 $drive->{bps_wr_max_length} || 1,
4973 $drive->{iops_max_length} || 1,
4974 $drive->{iops_rd_max_length} || 1,
4975 $drive->{iops_wr_max_length} || 1,
4985 if ($drive->{file} eq 'none
') {
4986 mon_cmd($vmid, "eject", force => JSON::true, id => "$opt");
4987 if (drive_is_cloudinit($old_drive)) {
4988 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $old_drive);
4991 my $path = get_iso_path($storecfg, $vmid, $drive->{file});
4993 # force eject if locked
4994 mon_cmd($vmid, "eject", force => JSON::true, id => "$opt");
4997 mon_cmd($vmid, "blockdev-change-medium",
4998 id => "$opt", filename => "$path");
5006 die "skip\n" if !$hotplug || $opt =~ m/(ide|sata)(\d+)/;
5008 PVE::Storage::activate_volumes($storecfg, [$drive->{file}]) if $drive->{file} !~ m|^/dev/.+|;
5009 vm_deviceplug($storecfg, $conf, $vmid, $opt, $drive, $arch, $machine_type);
5012 # called in locked context by incoming migration
5013 sub vm_migrate_get_nbd_disks {
5014 my ($storecfg, $conf, $replicated_volumes) = @_;
5016 my $local_volumes = {};
5017 PVE::QemuConfig->foreach_volume($conf, sub {
5018 my ($ds, $drive) = @_;
5020 return if drive_is_cdrom($drive);
5022 my $volid = $drive->{file};
5026 my ($storeid, $volname) = PVE::Storage::parse_volume_id($volid);
5028 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
5029 return if $scfg->{shared};
5031 # replicated disks re-use existing state via bitmap
5032 my $use_existing = $replicated_volumes->{$volid} ? 1 : 0;
5033 $local_volumes->{$ds} = [$volid, $storeid, $volname, $drive, $use_existing];
5035 return $local_volumes;
5038 # called in locked context by incoming migration
5039 sub vm_migrate_alloc_nbd_disks {
5040 my ($storecfg, $vmid, $source_volumes, $storagemap) = @_;
5045 foreach my $opt (sort keys %$source_volumes) {
5046 my ($volid, $storeid, $volname, $drive, $use_existing) = @{$source_volumes->{$opt}};
5048 if ($use_existing) {
5049 $nbd->{$opt}->{drivestr} = print_drive($drive);
5050 $nbd->{$opt}->{volid} = $volid;
5051 $nbd->{$opt}->{replicated} = 1;
5055 # If a remote storage is specified and the format of the original
5056 # volume is not available there, fall back to the default format.
5057 # Otherwise use the same format as the original.
5058 if (!$storagemap->{identity}) {
5059 $storeid = map_storage($storagemap, $storeid);
5060 my ($defFormat, $validFormats) = PVE::Storage::storage_default_format($storecfg, $storeid);
5061 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
5062 my $fileFormat = qemu_img_format($scfg, $volname);
5063 $format = (grep {$fileFormat eq $_} @{$validFormats}) ? $fileFormat : $defFormat;
5065 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
5066 $format = qemu_img_format($scfg, $volname);
5069 my $size = $drive->{size} / 1024;
5070 my $newvolid = PVE::Storage::vdisk_alloc($storecfg, $storeid, $vmid, $format, undef, $size);
5071 my $newdrive = $drive;
5072 $newdrive->{format} = $format;
5073 $newdrive->{file} = $newvolid;
5074 my $drivestr = print_drive($newdrive);
5075 $nbd->{$opt}->{drivestr} = $drivestr;
5076 $nbd->{$opt}->{volid} = $newvolid;
5082 # see vm_start_nolock for parameters, additionally:
5084 # storagemap = parsed storage map for allocating NBD disks
5086 my ($storecfg, $vmid, $params, $migrate_opts) = @_;
5088 return PVE::QemuConfig->lock_config($vmid, sub {
5089 my $conf = PVE::QemuConfig->load_config($vmid, $migrate_opts->{migratedfrom});
5091 die "you can't start a vm
if it
's a template\n"
5092 if !$params->{skiptemplate} && PVE::QemuConfig->is_template($conf);
5094 my $has_suspended_lock = PVE::QemuConfig->has_lock($conf, 'suspended
');
5095 my $has_backup_lock = PVE::QemuConfig->has_lock($conf, 'backup
');
5097 my $running = check_running($vmid, undef, $migrate_opts->{migratedfrom});
5099 if ($has_backup_lock && $running) {
5100 # a backup is currently running, attempt to start the guest in the
5101 # existing QEMU instance
5102 return vm_resume($vmid);
5105 PVE::QemuConfig->check_lock($conf)
5106 if !($params->{skiplock} || $has_suspended_lock);
5108 $params->{resume} = $has_suspended_lock || defined($conf->{vmstate});
5110 die "VM $vmid already running\n" if $running;
5112 if (my $storagemap = $migrate_opts->{storagemap}) {
5113 my $replicated = $migrate_opts->{replicated_volumes};
5114 my $disks = vm_migrate_get_nbd_disks($storecfg, $conf, $replicated);
5115 $migrate_opts->{nbd} = vm_migrate_alloc_nbd_disks($storecfg, $vmid, $disks, $storagemap);
5117 foreach my $opt (keys %{$migrate_opts->{nbd}}) {
5118 $conf->{$opt} = $migrate_opts->{nbd}->{$opt}->{drivestr};
5122 return vm_start_nolock($storecfg, $vmid, $conf, $params, $migrate_opts);
5128 # statefile => 'tcp
', 'unix
' for migration or path/volid for RAM state
5129 # skiplock => 0/1, skip checking for config lock
5130 # skiptemplate => 0/1, skip checking whether VM is template
5131 # forcemachine => to force Qemu machine (rollback/migration)
5132 # forcecpu => a QEMU '-cpu
' argument string to override get_cpu_options
5133 # timeout => in seconds
5134 # paused => start VM in paused state (backup)
5135 # resume => resume from hibernation
5146 # nbd => volumes for NBD exports (vm_migrate_alloc_nbd_disks)
5147 # migratedfrom => source node
5148 # spice_ticket => used for spice migration, passed via tunnel/stdin
5149 # network => CIDR of migration network
5150 # type => secure/insecure - tunnel over encrypted connection or plain-text
5151 # nbd_proto_version => int, 0 for TCP, 1 for UNIX
5152 # replicated_volumes = which volids should be re-used with bitmaps for nbd migration
5153 sub vm_start_nolock {
5154 my ($storecfg, $vmid, $conf, $params, $migrate_opts) = @_;
5156 my $statefile = $params->{statefile};
5157 my $resume = $params->{resume};
5159 my $migratedfrom = $migrate_opts->{migratedfrom};
5160 my $migration_type = $migrate_opts->{type};
5164 # clean up leftover reboot request files
5165 eval { clear_reboot_request($vmid); };
5168 if (!$statefile && scalar(keys %{$conf->{pending}})) {
5169 vmconfig_apply_pending($vmid, $conf, $storecfg);
5170 $conf = PVE::QemuConfig->load_config($vmid); # update/reload
5173 PVE::QemuServer::Cloudinit::generate_cloudinitconfig($conf, $vmid);
5175 my $defaults = load_defaults();
5177 # set environment variable useful inside network script
5178 $ENV{PVE_MIGRATED_FROM} = $migratedfrom if $migratedfrom;
5180 PVE::GuestHelpers::exec_hookscript($conf, $vmid, 'pre-start
', 1);
5182 my $forcemachine = $params->{forcemachine};
5183 my $forcecpu = $params->{forcecpu};
5185 # enforce machine and CPU type on suspended vm to ensure HW compatibility
5186 $forcemachine = $conf->{runningmachine};
5187 $forcecpu = $conf->{runningcpu};
5188 print "Resuming suspended VM\n";
5191 my ($cmd, $vollist, $spice_port) = config_to_command($storecfg, $vmid,
5192 $conf, $defaults, $forcemachine, $forcecpu, $params->{'pbs-backing
'});
5195 my $get_migration_ip = sub {
5196 my ($nodename) = @_;
5198 return $migration_ip if defined($migration_ip);
5200 my $cidr = $migrate_opts->{network};
5202 if (!defined($cidr)) {
5203 my $dc_conf = PVE::Cluster::cfs_read_file('datacenter
.cfg
');
5204 $cidr = $dc_conf->{migration}->{network};
5207 if (defined($cidr)) {
5208 my $ips = PVE::Network::get_local_ip_from_cidr($cidr);
5210 die "could not get IP: no address configured on local " .
5211 "node for network '$cidr'\n" if scalar(@$ips) == 0;
5213 die "could not get IP: multiple addresses configured on local " .
5214 "node for network '$cidr'\n" if scalar(@$ips) > 1;
5216 $migration_ip = @$ips[0];
5219 $migration_ip = PVE::Cluster::remote_node_ip($nodename, 1)
5220 if !defined($migration_ip);
5222 return $migration_ip;
5227 if ($statefile eq 'tcp
') {
5228 my $localip = "localhost";
5229 my $datacenterconf = PVE::Cluster::cfs_read_file('datacenter
.cfg
');
5230 my $nodename = nodename();
5232 if (!defined($migration_type)) {
5233 if (defined($datacenterconf->{migration}->{type})) {
5234 $migration_type = $datacenterconf->{migration}->{type};
5236 $migration_type = 'secure
';
5240 if ($migration_type eq 'insecure
') {
5241 $localip = $get_migration_ip->($nodename);
5242 $localip = "[$localip]" if Net::IP::ip_is_ipv6($localip);
5245 my $pfamily = PVE::Tools::get_host_address_family($nodename);
5246 my $migrate_port = PVE::Tools::next_migrate_port($pfamily);
5247 $migrate_uri = "tcp:${localip}:${migrate_port}";
5248 push @$cmd, '-incoming
', $migrate_uri;
5251 } elsif ($statefile eq 'unix
') {
5252 # should be default for secure migrations as a ssh TCP forward
5253 # tunnel is not deterministic reliable ready and fails regurarly
5254 # to set up in time, so use UNIX socket forwards
5255 my $socket_addr = "/run/qemu-server/$vmid.migrate";
5256 unlink $socket_addr;
5258 $migrate_uri = "unix:$socket_addr";
5260 push @$cmd, '-incoming
', $migrate_uri;
5263 } elsif (-e $statefile) {
5264 push @$cmd, '-loadstate
', $statefile;
5266 my $statepath = PVE::Storage::path($storecfg, $statefile);
5267 push @$vollist, $statefile;
5268 push @$cmd, '-loadstate
', $statepath;
5270 } elsif ($params->{paused}) {
5275 for (my $i = 0; $i < $PVE::QemuServer::PCI::MAX_HOSTPCI_DEVICES; $i++) {
5276 my $d = parse_hostpci($conf->{"hostpci$i"});
5278 my $pcidevices = $d->{pciid};
5279 foreach my $pcidevice (@$pcidevices) {
5280 my $pciid = $pcidevice->{id};
5282 my $info = PVE::SysFSTools::pci_device_info("$pciid");
5283 die "IOMMU not present\n" if !PVE::SysFSTools::check_iommu_support();
5284 die "no pci device info for device '$pciid'\n" if !$info;
5287 my $uuid = PVE::SysFSTools::generate_mdev_uuid($vmid, $i);
5288 PVE::SysFSTools::pci_create_mdev_device($pciid, $uuid, $d->{mdev});
5290 die "can't unbind
/bind PCI group to VFIO
'$pciid'\n"
5291 if !PVE::SysFSTools::pci_dev_group_bind_to_vfio($pciid);
5292 die "can
't reset PCI device '$pciid'\n"
5293 if $info->{has_fl_reset} && !PVE::SysFSTools::pci_dev_reset($info);
5298 PVE::Storage::activate_volumes($storecfg, $vollist);
5301 run_command(['/bin/systemctl
', 'stop
', "$vmid.scope"],
5302 outfunc => sub {}, errfunc => sub {});
5304 # Issues with the above 'stop
' not being fully completed are extremely rare, a very low
5305 # timeout should be more than enough here...
5306 PVE::Systemd::wait_for_unit_removed("$vmid.scope", 5);
5308 my $cpuunits = get_cpuunits($conf);
5310 my $start_timeout = $params->{timeout} // config_aware_timeout($conf, $resume);
5312 timeout => $statefile ? undef : $start_timeout,
5317 # when migrating, prefix QEMU output so other side can pick up any
5318 # errors that might occur and show the user
5319 if ($migratedfrom) {
5320 $run_params{quiet} = 1;
5321 $run_params{logfunc} = sub { print "QEMU: $_[0]\n" };
5325 Slice => 'qemu
.slice
',
5326 KillMode => 'process
',
5328 TimeoutStopUSec => ULONG_MAX, # infinity
5331 if (PVE::CGroup::cgroup_mode() == 2) {
5332 $cpuunits = 10000 if $cpuunits >= 10000; # else we get an error
5333 $properties{CPUWeight} = $cpuunits;
5335 $properties{CPUShares} = $cpuunits;
5338 if (my $cpulimit = $conf->{cpulimit}) {
5339 $properties{CPUQuota} = int($cpulimit * 100);
5341 $properties{timeout} = 10 if $statefile; # setting up the scope shoul be quick
5343 my $run_qemu = sub {
5344 PVE::Tools::run_fork sub {
5345 PVE::Systemd::enter_systemd_scope($vmid, "Proxmox VE VM $vmid", %properties);
5347 my $exitcode = run_command($cmd, %run_params);
5348 die "QEMU exited with code $exitcode\n" if $exitcode;
5352 if ($conf->{hugepages}) {
5355 my $hugepages_topology = PVE::QemuServer::Memory::hugepages_topology($conf);
5356 my $hugepages_host_topology = PVE::QemuServer::Memory::hugepages_host_topology();
5358 PVE::QemuServer::Memory::hugepages_mount();
5359 PVE::QemuServer::Memory::hugepages_allocate($hugepages_topology, $hugepages_host_topology);
5361 eval { $run_qemu->() };
5363 PVE::QemuServer::Memory::hugepages_reset($hugepages_host_topology)
5364 if !$conf->{keephugepages};
5368 PVE::QemuServer::Memory::hugepages_pre_deallocate($hugepages_topology)
5369 if !$conf->{keephugepages};
5371 eval { PVE::QemuServer::Memory::hugepages_update_locked($code); };
5374 eval { $run_qemu->() };
5378 # deactivate volumes if start fails
5379 eval { PVE::Storage::deactivate_volumes($storecfg, $vollist); };
5380 die "start failed: $err";
5383 print "migration listens on $migrate_uri\n" if $migrate_uri;
5384 $res->{migrate_uri} = $migrate_uri;
5386 if ($statefile && $statefile ne 'tcp
' && $statefile ne 'unix
') {
5387 eval { mon_cmd($vmid, "cont"); };
5391 #start nbd server for storage migration
5392 if (my $nbd = $migrate_opts->{nbd}) {
5393 my $nbd_protocol_version = $migrate_opts->{nbd_proto_version} // 0;
5395 my $migrate_storage_uri;
5396 # nbd_protocol_version > 0 for unix socket support
5397 if ($nbd_protocol_version > 0 && $migration_type eq 'secure
') {
5398 my $socket_path = "/run/qemu-server/$vmid\_nbd.migrate";
5399 mon_cmd($vmid, "nbd-server-start", addr => { type => 'unix
', data => { path => $socket_path } } );
5400 $migrate_storage_uri = "nbd:unix:$socket_path";
5402 my $nodename = nodename();
5403 my $localip = $get_migration_ip->($nodename);
5404 my $pfamily = PVE::Tools::get_host_address_family($nodename);
5405 my $storage_migrate_port = PVE::Tools::next_migrate_port($pfamily);
5407 mon_cmd($vmid, "nbd-server-start", addr => {
5410 host => "${localip}",
5411 port => "${storage_migrate_port}",
5414 $localip = "[$localip]" if Net::IP::ip_is_ipv6($localip);
5415 $migrate_storage_uri = "nbd:${localip}:${storage_migrate_port}";
5418 $res->{migrate_storage_uri} = $migrate_storage_uri;
5420 foreach my $opt (sort keys %$nbd) {
5421 my $drivestr = $nbd->{$opt}->{drivestr};
5422 my $volid = $nbd->{$opt}->{volid};
5423 mon_cmd($vmid, "nbd-server-add", device => "drive-$opt", writable => JSON::true );
5424 my $nbd_uri = "$migrate_storage_uri:exportname=drive-$opt";
5425 print "storage migration listens on $nbd_uri volume:$drivestr\n";
5426 print "re-using replicated volume: $opt - $volid\n"
5427 if $nbd->{$opt}->{replicated};
5429 $res->{drives}->{$opt} = $nbd->{$opt};
5430 $res->{drives}->{$opt}->{nbd_uri} = $nbd_uri;
5434 if ($migratedfrom) {
5436 set_migration_caps($vmid);
5441 print "spice listens on port $spice_port\n";
5442 $res->{spice_port} = $spice_port;
5443 if ($migrate_opts->{spice_ticket}) {
5444 mon_cmd($vmid, "set_password", protocol => 'spice
', password =>
5445 $migrate_opts->{spice_ticket});
5446 mon_cmd($vmid, "expire_password", protocol => 'spice
', time => "+30");
5451 mon_cmd($vmid, "balloon", value => $conf->{balloon}*1024*1024)
5452 if !$statefile && $conf->{balloon};
5454 foreach my $opt (keys %$conf) {
5455 next if $opt !~ m/^net\d+$/;
5456 my $nicconf = parse_net($conf->{$opt});
5457 qemu_set_link_status($vmid, $opt, 0) if $nicconf->{link_down};
5461 mon_cmd($vmid, 'qom-set
',
5462 path => "machine/peripheral/balloon0",
5463 property => "guest-stats-polling-interval",
5464 value => 2) if (!defined($conf->{balloon}) || $conf->{balloon});
5467 print "Resumed VM, removing state\n";
5468 if (my $vmstate = $conf->{vmstate}) {
5469 PVE::Storage::deactivate_volumes($storecfg, [$vmstate]);
5470 PVE::Storage::vdisk_free($storecfg, $vmstate);
5472 delete $conf->@{qw(lock vmstate runningmachine runningcpu)};
5473 PVE
::QemuConfig-
>write_config($vmid, $conf);
5476 PVE
::GuestHelpers
::exec_hookscript
($conf, $vmid, 'post-start');
5481 sub vm_commandline
{
5482 my ($storecfg, $vmid, $snapname) = @_;
5484 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5489 my $snapshot = $conf->{snapshots
}->{$snapname};
5490 die "snapshot '$snapname' does not exist\n" if !defined($snapshot);
5492 # check for machine or CPU overrides in snapshot
5493 $forcemachine = $snapshot->{runningmachine
};
5494 $forcecpu = $snapshot->{runningcpu
};
5496 $snapshot->{digest
} = $conf->{digest
}; # keep file digest for API
5501 my $defaults = load_defaults
();
5503 my $cmd = config_to_command
($storecfg, $vmid, $conf, $defaults,
5504 $forcemachine, $forcecpu);
5506 return PVE
::Tools
::cmd2string
($cmd);
5510 my ($vmid, $skiplock) = @_;
5512 PVE
::QemuConfig-
>lock_config($vmid, sub {
5514 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5516 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
5518 mon_cmd
($vmid, "system_reset");
5522 sub get_vm_volumes
{
5526 foreach_volid
($conf, sub {
5527 my ($volid, $attr) = @_;
5529 return if $volid =~ m
|^/|;
5531 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
5534 push @$vollist, $volid;
5540 sub vm_stop_cleanup
{
5541 my ($storecfg, $vmid, $conf, $keepActive, $apply_pending_changes) = @_;
5546 my $vollist = get_vm_volumes
($conf);
5547 PVE
::Storage
::deactivate_volumes
($storecfg, $vollist);
5550 foreach my $ext (qw(mon qmp pid vnc qga)) {
5551 unlink "/var/run/qemu-server/${vmid}.$ext";
5554 if ($conf->{ivshmem
}) {
5555 my $ivshmem = parse_property_string
($ivshmem_fmt, $conf->{ivshmem
});
5556 # just delete it for now, VMs which have this already open do not
5557 # are affected, but new VMs will get a separated one. If this
5558 # becomes an issue we either add some sort of ref-counting or just
5559 # add a "don't delete on stop" flag to the ivshmem format.
5560 unlink '/dev/shm/pve-shm-' . ($ivshmem->{name
} // $vmid);
5563 foreach my $key (keys %$conf) {
5564 next if $key !~ m/^hostpci(\d+)$/;
5565 my $hostpciindex = $1;
5566 my $d = parse_hostpci
($conf->{$key});
5567 my $uuid = PVE
::SysFSTools
::generate_mdev_uuid
($vmid, $hostpciindex);
5569 foreach my $pci (@{$d->{pciid
}}) {
5570 my $pciid = $pci->{id
};
5571 PVE
::SysFSTools
::pci_cleanup_mdev_device
($pciid, $uuid);
5575 vmconfig_apply_pending
($vmid, $conf, $storecfg) if $apply_pending_changes;
5577 warn $@ if $@; # avoid errors - just warn
5580 # call only in locked context
5582 my ($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive) = @_;
5584 my $pid = check_running
($vmid, $nocheck);
5589 $conf = PVE
::QemuConfig-
>load_config($vmid);
5590 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
5591 if (!defined($timeout) && $shutdown && $conf->{startup
}) {
5592 my $opts = PVE
::JSONSchema
::pve_parse_startup_order
($conf->{startup
});
5593 $timeout = $opts->{down
} if $opts->{down
};
5595 PVE
::GuestHelpers
::exec_hookscript
($conf, $vmid, 'pre-stop');
5600 if (defined($conf) && get_qga_key
($conf, 'enabled')) {
5601 mon_cmd
($vmid, "guest-shutdown", timeout
=> $timeout);
5603 mon_cmd
($vmid, "system_powerdown");
5606 mon_cmd
($vmid, "quit");
5612 $timeout = 60 if !defined($timeout);
5615 while (($count < $timeout) && check_running
($vmid, $nocheck)) {
5620 if ($count >= $timeout) {
5622 warn "VM still running - terminating now with SIGTERM\n";
5625 die "VM quit/powerdown failed - got timeout\n";
5628 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 1) if $conf;
5632 if (!check_running
($vmid, $nocheck)) {
5633 warn "Unexpected: VM shutdown command failed, but VM not running anymore..\n";
5637 warn "VM quit/powerdown failed - terminating now with SIGTERM\n";
5640 die "VM quit/powerdown failed\n";
5648 while (($count < $timeout) && check_running
($vmid, $nocheck)) {
5653 if ($count >= $timeout) {
5654 warn "VM still running - terminating now with SIGKILL\n";
5659 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 1) if $conf;
5662 # Note: use $nocheck to skip tests if VM configuration file exists.
5663 # We need that when migration VMs to other nodes (files already moved)
5664 # Note: we set $keepActive in vzdump stop mode - volumes need to stay active
5666 my ($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive, $migratedfrom) = @_;
5668 $force = 1 if !defined($force) && !$shutdown;
5671 my $pid = check_running
($vmid, $nocheck, $migratedfrom);
5672 kill 15, $pid if $pid;
5673 my $conf = PVE
::QemuConfig-
>load_config($vmid, $migratedfrom);
5674 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 0);
5678 PVE
::QemuConfig-
>lock_config($vmid, sub {
5679 _do_vm_stop
($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive);
5684 my ($vmid, $timeout) = @_;
5686 PVE
::QemuConfig-
>lock_config($vmid, sub {
5689 # only reboot if running, as qmeventd starts it again on a stop event
5690 return if !check_running
($vmid);
5692 create_reboot_request
($vmid);
5694 my $storecfg = PVE
::Storage
::config
();
5695 _do_vm_stop
($storecfg, $vmid, undef, undef, $timeout, 1);
5699 # avoid that the next normal shutdown will be confused for a reboot
5700 clear_reboot_request
($vmid);
5706 # note: if using the statestorage parameter, the caller has to check privileges
5708 my ($vmid, $skiplock, $includestate, $statestorage) = @_;
5715 PVE
::QemuConfig-
>lock_config($vmid, sub {
5717 $conf = PVE
::QemuConfig-
>load_config($vmid);
5719 my $is_backing_up = PVE
::QemuConfig-
>has_lock($conf, 'backup');
5720 PVE
::QemuConfig-
>check_lock($conf)
5721 if !($skiplock || $is_backing_up);
5723 die "cannot suspend to disk during backup\n"
5724 if $is_backing_up && $includestate;
5726 if ($includestate) {
5727 $conf->{lock} = 'suspending';
5728 my $date = strftime
("%Y-%m-%d", localtime(time()));
5729 $storecfg = PVE
::Storage
::config
();
5730 if (!$statestorage) {
5731 $statestorage = find_vmstate_storage
($conf, $storecfg);
5732 # check permissions for the storage
5733 my $rpcenv = PVE
::RPCEnvironment
::get
();
5734 if ($rpcenv->{type
} ne 'cli') {
5735 my $authuser = $rpcenv->get_user();
5736 $rpcenv->check($authuser, "/storage/$statestorage", ['Datastore.AllocateSpace']);
5741 $vmstate = PVE
::QemuConfig-
>__snapshot_save_vmstate(
5742 $vmid, $conf, "suspend-$date", $storecfg, $statestorage, 1);
5743 $path = PVE
::Storage
::path
($storecfg, $vmstate);
5744 PVE
::QemuConfig-
>write_config($vmid, $conf);
5746 mon_cmd
($vmid, "stop");
5750 if ($includestate) {
5752 PVE
::Storage
::activate_volumes
($storecfg, [$vmstate]);
5755 set_migration_caps
($vmid, 1);
5756 mon_cmd
($vmid, "savevm-start", statefile
=> $path);
5758 my $state = mon_cmd
($vmid, "query-savevm");
5759 if (!$state->{status
}) {
5760 die "savevm not active\n";
5761 } elsif ($state->{status
} eq 'active') {
5764 } elsif ($state->{status
} eq 'completed') {
5765 print "State saved, quitting\n";
5767 } elsif ($state->{status
} eq 'failed' && $state->{error
}) {
5768 die "query-savevm failed with error '$state->{error}'\n"
5770 die "query-savevm returned status '$state->{status}'\n";
5776 PVE
::QemuConfig-
>lock_config($vmid, sub {
5777 $conf = PVE
::QemuConfig-
>load_config($vmid);
5779 # cleanup, but leave suspending lock, to indicate something went wrong
5781 mon_cmd
($vmid, "savevm-end");
5782 PVE
::Storage
::deactivate_volumes
($storecfg, [$vmstate]);
5783 PVE
::Storage
::vdisk_free
($storecfg, $vmstate);
5784 delete $conf->@{qw(vmstate runningmachine runningcpu)};
5785 PVE
::QemuConfig-
>write_config($vmid, $conf);
5791 die "lock changed unexpectedly\n"
5792 if !PVE
::QemuConfig-
>has_lock($conf, 'suspending');
5794 mon_cmd
($vmid, "quit");
5795 $conf->{lock} = 'suspended';
5796 PVE
::QemuConfig-
>write_config($vmid, $conf);
5802 my ($vmid, $skiplock, $nocheck) = @_;
5804 PVE
::QemuConfig-
>lock_config($vmid, sub {
5805 my $res = mon_cmd
($vmid, 'query-status');
5806 my $resume_cmd = 'cont';
5809 if ($res->{status
}) {
5810 return if $res->{status
} eq 'running'; # job done, go home
5811 $resume_cmd = 'system_wakeup' if $res->{status
} eq 'suspended';
5812 $reset = 1 if $res->{status
} eq 'shutdown';
5817 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5819 PVE
::QemuConfig-
>check_lock($conf)
5820 if !($skiplock || PVE
::QemuConfig-
>has_lock($conf, 'backup'));
5824 # required if a VM shuts down during a backup and we get a resume
5825 # request before the backup finishes for example
5826 mon_cmd
($vmid, "system_reset");
5828 mon_cmd
($vmid, $resume_cmd);
5833 my ($vmid, $skiplock, $key) = @_;
5835 PVE
::QemuConfig-
>lock_config($vmid, sub {
5837 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5839 # there is no qmp command, so we use the human monitor command
5840 my $res = PVE
::QemuServer
::Monitor
::hmp_cmd
($vmid, "sendkey $key");
5841 die $res if $res ne '';
5845 # vzdump restore implementaion
5847 sub tar_archive_read_firstfile
{
5848 my $archive = shift;
5850 die "ERROR: file '$archive' does not exist\n" if ! -f
$archive;
5852 # try to detect archive type first
5853 my $pid = open (my $fh, '-|', 'tar', 'tf', $archive) ||
5854 die "unable to open file '$archive'\n";
5855 my $firstfile = <$fh>;
5859 die "ERROR: archive contaions no data\n" if !$firstfile;
5865 sub tar_restore_cleanup
{
5866 my ($storecfg, $statfile) = @_;
5868 print STDERR
"starting cleanup\n";
5870 if (my $fd = IO
::File-
>new($statfile, "r")) {
5871 while (defined(my $line = <$fd>)) {
5872 if ($line =~ m/vzdump:([^\s:]*):(\S+)$/) {
5875 if ($volid =~ m
|^/|) {
5876 unlink $volid || die 'unlink failed\n';
5878 PVE
::Storage
::vdisk_free
($storecfg, $volid);
5880 print STDERR
"temporary volume '$volid' sucessfuly removed\n";
5882 print STDERR
"unable to cleanup '$volid' - $@" if $@;
5884 print STDERR
"unable to parse line in statfile - $line";
5891 sub restore_file_archive
{
5892 my ($archive, $vmid, $user, $opts) = @_;
5894 return restore_vma_archive
($archive, $vmid, $user, $opts)
5897 my $info = PVE
::Storage
::archive_info
($archive);
5898 my $format = $opts->{format
} // $info->{format
};
5899 my $comp = $info->{compression
};
5901 # try to detect archive format
5902 if ($format eq 'tar') {
5903 return restore_tar_archive
($archive, $vmid, $user, $opts);
5905 return restore_vma_archive
($archive, $vmid, $user, $opts, $comp);
5909 # hepler to remove disks that will not be used after restore
5910 my $restore_cleanup_oldconf = sub {
5911 my ($storecfg, $vmid, $oldconf, $virtdev_hash) = @_;
5913 PVE
::QemuConfig-
>foreach_volume($oldconf, sub {
5914 my ($ds, $drive) = @_;
5916 return if drive_is_cdrom
($drive, 1);
5918 my $volid = $drive->{file
};
5919 return if !$volid || $volid =~ m
|^/|;
5921 my ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid);
5922 return if !$path || !$owner || ($owner != $vmid);
5924 # Note: only delete disk we want to restore
5925 # other volumes will become unused
5926 if ($virtdev_hash->{$ds}) {
5927 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid); };
5934 # delete vmstate files, after the restore we have no snapshots anymore
5935 foreach my $snapname (keys %{$oldconf->{snapshots
}}) {
5936 my $snap = $oldconf->{snapshots
}->{$snapname};
5937 if ($snap->{vmstate
}) {
5938 eval { PVE
::Storage
::vdisk_free
($storecfg, $snap->{vmstate
}); };
5946 # Helper to parse vzdump backup device hints
5948 # $rpcenv: Environment, used to ckeck storage permissions
5949 # $user: User ID, to check storage permissions
5950 # $storecfg: Storage configuration
5951 # $fh: the file handle for reading the configuration
5952 # $devinfo: should contain device sizes for all backu-up'ed devices
5953 # $options: backup options (pool, default storage)
5955 # Return: $virtdev_hash, updates $devinfo (add devname, virtdev, format, storeid)
5956 my $parse_backup_hints = sub {
5957 my ($rpcenv, $user, $storecfg, $fh, $devinfo, $options) = @_;
5959 my $virtdev_hash = {};
5961 while (defined(my $line = <$fh>)) {
5962 if ($line =~ m/^\#qmdump\#map:(\S+):(\S+):(\S*):(\S*):$/) {
5963 my ($virtdev, $devname, $storeid, $format) = ($1, $2, $3, $4);
5964 die "archive does not contain data for drive '$virtdev'\n"
5965 if !$devinfo->{$devname};
5967 if (defined($options->{storage
})) {
5968 $storeid = $options->{storage
} || 'local';
5969 } elsif (!$storeid) {
5972 $format = 'raw' if !$format;
5973 $devinfo->{$devname}->{devname
} = $devname;
5974 $devinfo->{$devname}->{virtdev
} = $virtdev;
5975 $devinfo->{$devname}->{format
} = $format;
5976 $devinfo->{$devname}->{storeid
} = $storeid;
5978 # check permission on storage
5979 my $pool = $options->{pool
}; # todo: do we need that?
5980 if ($user ne 'root@pam') {
5981 $rpcenv->check($user, "/storage/$storeid", ['Datastore.AllocateSpace']);
5984 $virtdev_hash->{$virtdev} = $devinfo->{$devname};
5985 } elsif ($line =~ m/^((?:ide|sata|scsi)\d+):\s*(.*)\s*$/) {
5987 my $drive = parse_drive
($virtdev, $2);
5988 if (drive_is_cloudinit
($drive)) {
5989 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($drive->{file
});
5990 $storeid = $options->{storage
} if defined ($options->{storage
});
5991 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
5992 my $format = qemu_img_format
($scfg, $volname); # has 'raw' fallback
5994 $virtdev_hash->{$virtdev} = {
5996 storeid
=> $storeid,
5997 size
=> PVE
::QemuServer
::Cloudinit
::CLOUDINIT_DISK_SIZE
,
6004 return $virtdev_hash;
6007 # Helper to allocate and activate all volumes required for a restore
6009 # $storecfg: Storage configuration
6010 # $virtdev_hash: as returned by parse_backup_hints()
6012 # Returns: { $virtdev => $volid }
6013 my $restore_allocate_devices = sub {
6014 my ($storecfg, $virtdev_hash, $vmid) = @_;
6017 foreach my $virtdev (sort keys %$virtdev_hash) {
6018 my $d = $virtdev_hash->{$virtdev};
6019 my $alloc_size = int(($d->{size
} + 1024 - 1)/1024);
6020 my $storeid = $d->{storeid
};
6021 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
6023 # test if requested format is supported
6024 my ($defFormat, $validFormats) = PVE
::Storage
::storage_default_format
($storecfg, $storeid);
6025 my $supported = grep { $_ eq $d->{format
} } @$validFormats;
6026 $d->{format
} = $defFormat if !$supported;
6029 if ($d->{is_cloudinit
}) {
6030 $name = "vm-$vmid-cloudinit";
6031 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
6032 if ($scfg->{path
}) {
6033 $name .= ".$d->{format}";
6037 my $volid = PVE
::Storage
::vdisk_alloc
(
6038 $storecfg, $storeid, $vmid, $d->{format
}, $name, $alloc_size);
6040 print STDERR
"new volume ID is '$volid'\n";
6041 $d->{volid
} = $volid;
6043 PVE
::Storage
::activate_volumes
($storecfg, [$volid]);
6045 $map->{$virtdev} = $volid;
6051 sub restore_update_config_line
{
6052 my ($cookie, $map, $line, $unique) = @_;
6054 return '' if $line =~ m/^\#qmdump\#/;
6055 return '' if $line =~ m/^\#vzdump\#/;
6056 return '' if $line =~ m/^lock:/;
6057 return '' if $line =~ m/^unused\d+:/;
6058 return '' if $line =~ m/^parent:/;
6062 my $dc = PVE
::Cluster
::cfs_read_file
('datacenter.cfg');
6063 if (($line =~ m/^(vlan(\d+)):\s*(\S+)\s*$/)) {
6064 # try to convert old 1.X settings
6065 my ($id, $ind, $ethcfg) = ($1, $2, $3);
6066 foreach my $devconfig (PVE
::Tools
::split_list
($ethcfg)) {
6067 my ($model, $macaddr) = split(/\=/, $devconfig);
6068 $macaddr = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
}) if !$macaddr || $unique;
6071 bridge
=> "vmbr$ind",
6072 macaddr
=> $macaddr,
6074 my $netstr = print_net
($net);
6076 $res .= "net$cookie->{netcount}: $netstr\n";
6077 $cookie->{netcount
}++;
6079 } elsif (($line =~ m/^(net\d+):\s*(\S+)\s*$/) && $unique) {
6080 my ($id, $netstr) = ($1, $2);
6081 my $net = parse_net
($netstr);
6082 $net->{macaddr
} = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
}) if $net->{macaddr
};
6083 $netstr = print_net
($net);
6084 $res .= "$id: $netstr\n";
6085 } elsif ($line =~ m/^((ide|scsi|virtio|sata|efidisk)\d+):\s*(\S+)\s*$/) {
6088 my $di = parse_drive
($virtdev, $value);
6089 if (defined($di->{backup
}) && !$di->{backup
}) {
6091 } elsif ($map->{$virtdev}) {
6092 delete $di->{format
}; # format can change on restore
6093 $di->{file
} = $map->{$virtdev};
6094 $value = print_drive
($di);
6095 $res .= "$virtdev: $value\n";
6099 } elsif (($line =~ m/^vmgenid: (.*)/)) {
6101 if ($vmgenid ne '0') {
6102 # always generate a new vmgenid if there was a valid one setup
6103 $vmgenid = generate_uuid
();
6105 $res .= "vmgenid: $vmgenid\n";
6106 } elsif (($line =~ m/^(smbios1: )(.*)/) && $unique) {
6107 my ($uuid, $uuid_str);
6108 UUID
::generate
($uuid);
6109 UUID
::unparse
($uuid, $uuid_str);
6110 my $smbios1 = parse_smbios1
($2);
6111 $smbios1->{uuid
} = $uuid_str;
6112 $res .= $1.print_smbios1
($smbios1)."\n";
6120 my $restore_deactivate_volumes = sub {
6121 my ($storecfg, $devinfo) = @_;
6124 foreach my $devname (keys %$devinfo) {
6125 my $volid = $devinfo->{$devname}->{volid
};
6126 push @$vollist, $volid if $volid;
6129 PVE
::Storage
::deactivate_volumes
($storecfg, $vollist);
6132 my $restore_destroy_volumes = sub {
6133 my ($storecfg, $devinfo) = @_;
6135 foreach my $devname (keys %$devinfo) {
6136 my $volid = $devinfo->{$devname}->{volid
};
6139 if ($volid =~ m
|^/|) {
6140 unlink $volid || die 'unlink failed\n';
6142 PVE
::Storage
::vdisk_free
($storecfg, $volid);
6144 print STDERR
"temporary volume '$volid' sucessfuly removed\n";
6146 print STDERR
"unable to cleanup '$volid' - $@" if $@;
6151 my ($cfg, $vmid) = @_;
6153 my $info = PVE
::Storage
::vdisk_list
($cfg, undef, $vmid, undef, 'images');
6155 my $volid_hash = {};
6156 foreach my $storeid (keys %$info) {
6157 foreach my $item (@{$info->{$storeid}}) {
6158 next if !($item->{volid
} && $item->{size
});
6159 $item->{path
} = PVE
::Storage
::path
($cfg, $item->{volid
});
6160 $volid_hash->{$item->{volid
}} = $item;
6167 sub update_disk_config
{
6168 my ($vmid, $conf, $volid_hash) = @_;
6171 my $prefix = "VM $vmid";
6173 # used and unused disks
6174 my $referenced = {};
6176 # Note: it is allowed to define multiple storages with same path (alias), so
6177 # we need to check both 'volid' and real 'path' (two different volid can point
6178 # to the same path).
6180 my $referencedpath = {};
6183 PVE
::QemuConfig-
>foreach_volume($conf, sub {
6184 my ($opt, $drive) = @_;
6186 my $volid = $drive->{file
};
6188 my $volume = $volid_hash->{$volid};
6190 # mark volid as "in-use" for next step
6191 $referenced->{$volid} = 1;
6192 if ($volume && (my $path = $volume->{path
})) {
6193 $referencedpath->{$path} = 1;
6196 return if drive_is_cdrom
($drive);
6199 my ($updated, $msg) = PVE
::QemuServer
::Drive
::update_disksize
($drive, $volume->{size
});
6200 if (defined($updated)) {
6202 $conf->{$opt} = print_drive
($updated);
6203 print "$prefix ($opt): $msg\n";
6207 # remove 'unusedX' entry if volume is used
6208 PVE
::QemuConfig-
>foreach_unused_volume($conf, sub {
6209 my ($opt, $drive) = @_;
6211 my $volid = $drive->{file
};
6215 $path = $volid_hash->{$volid}->{path
} if $volid_hash->{$volid};
6216 if ($referenced->{$volid} || ($path && $referencedpath->{$path})) {
6217 print "$prefix remove entry '$opt', its volume '$volid' is in use\n";
6219 delete $conf->{$opt};
6222 $referenced->{$volid} = 1;
6223 $referencedpath->{$path} = 1 if $path;
6226 foreach my $volid (sort keys %$volid_hash) {
6227 next if $volid =~ m/vm-$vmid-state-/;
6228 next if $referenced->{$volid};
6229 my $path = $volid_hash->{$volid}->{path
};
6230 next if !$path; # just to be sure
6231 next if $referencedpath->{$path};
6233 my $key = PVE
::QemuConfig-
>add_unused_volume($conf, $volid);
6234 print "$prefix add unreferenced volume '$volid' as '$key' to config\n";
6235 $referencedpath->{$path} = 1; # avoid to add more than once (aliases)
6242 my ($vmid, $nolock, $dryrun) = @_;
6244 my $cfg = PVE
::Storage
::config
();
6246 print "rescan volumes...\n";
6247 my $volid_hash = scan_volids
($cfg, $vmid);
6249 my $updatefn = sub {
6252 my $conf = PVE
::QemuConfig-
>load_config($vmid);
6254 PVE
::QemuConfig-
>check_lock($conf);
6257 foreach my $volid (keys %$volid_hash) {
6258 my $info = $volid_hash->{$volid};
6259 $vm_volids->{$volid} = $info if $info->{vmid
} && $info->{vmid
} == $vmid;
6262 my $changes = update_disk_config
($vmid, $conf, $vm_volids);
6264 PVE
::QemuConfig-
>write_config($vmid, $conf) if $changes && !$dryrun;
6267 if (defined($vmid)) {
6271 PVE
::QemuConfig-
>lock_config($vmid, $updatefn, $vmid);
6274 my $vmlist = config_list
();
6275 foreach my $vmid (keys %$vmlist) {
6279 PVE
::QemuConfig-
>lock_config($vmid, $updatefn, $vmid);
6285 sub restore_proxmox_backup_archive
{
6286 my ($archive, $vmid, $user, $options) = @_;
6288 my $storecfg = PVE
::Storage
::config
();
6290 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($archive);
6291 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
6293 my $fingerprint = $scfg->{fingerprint
};
6294 my $keyfile = PVE
::Storage
::PBSPlugin
::pbs_encryption_key_file_name
($storecfg, $storeid);
6296 my $repo = PVE
::PBSClient
::get_repository
($scfg);
6298 # This is only used for `pbs-restore` and the QEMU PBS driver (live-restore)
6299 my $password = PVE
::Storage
::PBSPlugin
::pbs_get_password
($scfg, $storeid);
6300 local $ENV{PBS_PASSWORD
} = $password;
6301 local $ENV{PBS_FINGERPRINT
} = $fingerprint if defined($fingerprint);
6303 my ($vtype, $pbs_backup_name, undef, undef, undef, undef, $format) =
6304 PVE
::Storage
::parse_volname
($storecfg, $archive);
6306 die "got unexpected vtype '$vtype'\n" if $vtype ne 'backup';
6308 die "got unexpected backup format '$format'\n" if $format ne 'pbs-vm';
6310 my $tmpdir = "/var/tmp/vzdumptmp$$";
6314 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6315 # disable interrupts (always do cleanups)
6319 local $SIG{HUP
} = sub { print STDERR
"got interrupt - ignored\n"; };
6321 # Note: $oldconf is undef if VM does not exists
6322 my $cfs_path = PVE
::QemuConfig-
>cfs_config_path($vmid);
6323 my $oldconf = PVE
::Cluster
::cfs_read_file
($cfs_path);
6324 my $new_conf_raw = '';
6326 my $rpcenv = PVE
::RPCEnvironment
::get
();
6335 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6337 my $cfgfn = "$tmpdir/qemu-server.conf";
6338 my $firewall_config_fn = "$tmpdir/fw.conf";
6339 my $index_fn = "$tmpdir/index.json";
6341 my $cmd = "restore";
6343 my $param = [$pbs_backup_name, "index.json", $index_fn];
6344 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6345 my $index = PVE
::Tools
::file_get_contents
($index_fn);
6346 $index = decode_json
($index);
6348 # print Dumper($index);
6349 foreach my $info (@{$index->{files
}}) {
6350 if ($info->{filename
} =~ m/^(drive-\S+).img.fidx$/) {
6352 if ($info->{size
} =~ m/^(\d+)$/) { # untaint size
6353 $devinfo->{$devname}->{size
} = $1;
6355 die "unable to parse file size in 'index.json' - got '$info->{size}'\n";
6360 my $is_qemu_server_backup = scalar(
6361 grep { $_->{filename
} eq 'qemu-server.conf.blob' } @{$index->{files
}}
6363 if (!$is_qemu_server_backup) {
6364 die "backup does not look like a qemu-server backup (missing 'qemu-server.conf' file)\n";
6366 my $has_firewall_config = scalar(grep { $_->{filename
} eq 'fw.conf.blob' } @{$index->{files
}});
6368 $param = [$pbs_backup_name, "qemu-server.conf", $cfgfn];
6369 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6371 if ($has_firewall_config) {
6372 $param = [$pbs_backup_name, "fw.conf", $firewall_config_fn];
6373 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6375 my $pve_firewall_dir = '/etc/pve/firewall';
6376 mkdir $pve_firewall_dir; # make sure the dir exists
6377 PVE
::Tools
::file_copy
($firewall_config_fn, "${pve_firewall_dir}/$vmid.fw");
6380 my $fh = IO
::File-
>new($cfgfn, "r") ||
6381 die "unable to read qemu-server.conf - $!\n";
6383 my $virtdev_hash = $parse_backup_hints->($rpcenv, $user, $storecfg, $fh, $devinfo, $options);
6385 # fixme: rate limit?
6387 # create empty/temp config
6388 PVE
::Tools
::file_set_contents
($conffile, "memory: 128\nlock: create");
6390 $restore_cleanup_oldconf->($storecfg, $vmid, $oldconf, $virtdev_hash) if $oldconf;
6393 my $map = $restore_allocate_devices->($storecfg, $virtdev_hash, $vmid);
6395 foreach my $virtdev (sort keys %$virtdev_hash) {
6396 my $d = $virtdev_hash->{$virtdev};
6397 next if $d->{is_cloudinit
}; # no need to restore cloudinit
6399 # for live-restore we only want to preload the efidisk
6400 next if $options->{live
} && $virtdev ne 'efidisk0';
6402 my $volid = $d->{volid
};
6404 my $path = PVE
::Storage
::path
($storecfg, $volid);
6406 my $pbs_restore_cmd = [
6407 '/usr/bin/pbs-restore',
6408 '--repository', $repo,
6410 "$d->{devname}.img.fidx",
6415 push @$pbs_restore_cmd, '--format', $d->{format
} if $d->{format
};
6416 push @$pbs_restore_cmd, '--keyfile', $keyfile if -e
$keyfile;
6418 if (PVE
::Storage
::volume_has_feature
($storecfg, 'sparseinit', $volid)) {
6419 push @$pbs_restore_cmd, '--skip-zero';
6422 my $dbg_cmdstring = PVE
::Tools
::cmd2string
($pbs_restore_cmd);
6423 print "restore proxmox backup image: $dbg_cmdstring\n";
6424 run_command
($pbs_restore_cmd);
6427 $fh->seek(0, 0) || die "seek failed - $!\n";
6429 my $cookie = { netcount
=> 0 };
6430 while (defined(my $line = <$fh>)) {
6431 $new_conf_raw .= restore_update_config_line
(
6443 if ($err || !$options->{live
}) {
6444 $restore_deactivate_volumes->($storecfg, $devinfo);
6450 $restore_destroy_volumes->($storecfg, $devinfo);
6454 if ($options->{live
}) {
6455 # keep lock during live-restore
6456 $new_conf_raw .= "\nlock: create";
6459 PVE
::Tools
::file_set_contents
($conffile, $new_conf_raw);
6461 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6463 eval { rescan
($vmid, 1); };
6466 PVE
::AccessControl
::add_vm_to_pool
($vmid, $options->{pool
}) if $options->{pool
};
6468 if ($options->{live
}) {
6474 local $SIG{PIPE
} = sub { die "got signal ($!) - abort\n"; };
6476 my $conf = PVE
::QemuConfig-
>load_config($vmid);
6477 die "cannot do live-restore for template\n" if PVE
::QemuConfig-
>is_template($conf);
6479 delete $devinfo->{'drive-efidisk0'}; # this special drive is already restored before start
6480 pbs_live_restore
($vmid, $conf, $storecfg, $devinfo, $repo, $keyfile, $pbs_backup_name);
6482 PVE
::QemuConfig-
>remove_lock($vmid, "create");
6486 sub pbs_live_restore
{
6487 my ($vmid, $conf, $storecfg, $restored_disks, $repo, $keyfile, $snap) = @_;
6489 print "starting VM for live-restore\n";
6490 print "repository: '$repo', snapshot: '$snap'\n";
6492 my $pbs_backing = {};
6493 for my $ds (keys %$restored_disks) {
6494 $ds =~ m/^drive-(.*)$/;
6496 $pbs_backing->{$confname} = {
6497 repository
=> $repo,
6499 archive
=> "$ds.img.fidx",
6501 $pbs_backing->{$confname}->{keyfile
} = $keyfile if -e
$keyfile;
6503 my $drive = parse_drive
($confname, $conf->{$confname});
6504 print "restoring '$ds' to '$drive->{file}'\n";
6507 my $drives_streamed = 0;
6509 # make sure HA doesn't interrupt our restore by stopping the VM
6510 if (PVE
::HA
::Config
::vm_is_ha_managed
($vmid)) {
6511 run_command
(['ha-manager', 'set', "vm:$vmid", '--state', 'started']);
6514 # start VM with backing chain pointing to PBS backup, environment vars for PBS driver
6515 # in QEMU (PBS_PASSWORD and PBS_FINGERPRINT) are already set by our caller
6516 vm_start_nolock
($storecfg, $vmid, $conf, {paused
=> 1, 'pbs-backing' => $pbs_backing}, {});
6518 my $qmeventd_fd = register_qmeventd_handle
($vmid);
6520 # begin streaming, i.e. data copy from PBS to target disk for every vol,
6521 # this will effectively collapse the backing image chain consisting of
6522 # [target <- alloc-track -> PBS snapshot] to just [target] (alloc-track
6523 # removes itself once all backing images vanish with 'auto-remove=on')
6525 for my $ds (sort keys %$restored_disks) {
6526 my $job_id = "restore-$ds";
6527 mon_cmd
($vmid, 'block-stream',
6528 'job-id' => $job_id,
6531 $jobs->{$job_id} = {};
6534 mon_cmd
($vmid, 'cont');
6535 qemu_drive_mirror_monitor
($vmid, undef, $jobs, 'auto', 0, 'stream');
6537 print "restore-drive jobs finished successfully, removing all tracking block devices"
6538 ." to disconnect from Proxmox Backup Server\n";
6540 for my $ds (sort keys %$restored_disks) {
6541 mon_cmd
($vmid, 'blockdev-del', 'node-name' => "$ds-pbs");
6544 close($qmeventd_fd);
6550 warn "An error occured during live-restore: $err\n";
6551 _do_vm_stop
($storecfg, $vmid, 1, 1, 10, 0, 1);
6552 die "live-restore failed\n";
6556 sub restore_vma_archive
{
6557 my ($archive, $vmid, $user, $opts, $comp) = @_;
6559 my $readfrom = $archive;
6561 my $cfg = PVE
::Storage
::config
();
6563 my $bwlimit = $opts->{bwlimit
};
6565 my $dbg_cmdstring = '';
6566 my $add_pipe = sub {
6568 push @$commands, $cmd;
6569 $dbg_cmdstring .= ' | ' if length($dbg_cmdstring);
6570 $dbg_cmdstring .= PVE
::Tools
::cmd2string
($cmd);
6575 if ($archive eq '-') {
6578 # If we use a backup from a PVE defined storage we also consider that
6579 # storage's rate limit:
6580 my (undef, $volid) = PVE
::Storage
::path_to_volume_id
($cfg, $archive);
6581 if (defined($volid)) {
6582 my ($sid, undef) = PVE
::Storage
::parse_volume_id
($volid);
6583 my $readlimit = PVE
::Storage
::get_bandwidth_limit
('restore', [$sid], $bwlimit);
6585 print STDERR
"applying read rate limit: $readlimit\n";
6586 my $cstream = ['cstream', '-t', $readlimit*1024, '--', $readfrom];
6587 $add_pipe->($cstream);
6593 my $info = PVE
::Storage
::decompressor_info
('vma', $comp);
6594 my $cmd = $info->{decompressor
};
6595 push @$cmd, $readfrom;
6599 my $tmpdir = "/var/tmp/vzdumptmp$$";
6602 # disable interrupts (always do cleanups)
6606 local $SIG{HUP
} = sub { warn "got interrupt - ignored\n"; };
6608 my $mapfifo = "/var/tmp/vzdumptmp$$.fifo";
6609 POSIX
::mkfifo
($mapfifo, 0600);
6611 my $openfifo = sub { open($fifofh, '>', $mapfifo) or die $! };
6613 $add_pipe->(['vma', 'extract', '-v', '-r', $mapfifo, $readfrom, $tmpdir]);
6620 my $rpcenv = PVE
::RPCEnvironment
::get
();
6622 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6624 # Note: $oldconf is undef if VM does not exist
6625 my $cfs_path = PVE
::QemuConfig-
>cfs_config_path($vmid);
6626 my $oldconf = PVE
::Cluster
::cfs_read_file
($cfs_path);
6627 my $new_conf_raw = '';
6631 my $print_devmap = sub {
6632 my $cfgfn = "$tmpdir/qemu-server.conf";
6634 # we can read the config - that is already extracted
6635 my $fh = IO
::File-
>new($cfgfn, "r") ||
6636 die "unable to read qemu-server.conf - $!\n";
6638 my $fwcfgfn = "$tmpdir/qemu-server.fw";
6640 my $pve_firewall_dir = '/etc/pve/firewall';
6641 mkdir $pve_firewall_dir; # make sure the dir exists
6642 PVE
::Tools
::file_copy
($fwcfgfn, "${pve_firewall_dir}/$vmid.fw");
6645 my $virtdev_hash = $parse_backup_hints->($rpcenv, $user, $cfg, $fh, $devinfo, $opts);
6647 foreach my $info (values %{$virtdev_hash}) {
6648 my $storeid = $info->{storeid
};
6649 next if defined($storage_limits{$storeid});
6651 my $limit = PVE
::Storage
::get_bandwidth_limit
('restore', [$storeid], $bwlimit) // 0;
6652 print STDERR
"rate limit for storage $storeid: $limit KiB/s\n" if $limit;
6653 $storage_limits{$storeid} = $limit * 1024;
6656 foreach my $devname (keys %$devinfo) {
6657 die "found no device mapping information for device '$devname'\n"
6658 if !$devinfo->{$devname}->{virtdev
};
6661 # create empty/temp config
6663 PVE
::Tools
::file_set_contents
($conffile, "memory: 128\n");
6664 $restore_cleanup_oldconf->($cfg, $vmid, $oldconf, $virtdev_hash);
6668 my $map = $restore_allocate_devices->($cfg, $virtdev_hash, $vmid);
6670 # print restore information to $fifofh
6671 foreach my $virtdev (sort keys %$virtdev_hash) {
6672 my $d = $virtdev_hash->{$virtdev};
6673 next if $d->{is_cloudinit
}; # no need to restore cloudinit
6675 my $storeid = $d->{storeid
};
6676 my $volid = $d->{volid
};
6679 if (my $limit = $storage_limits{$storeid}) {
6680 $map_opts .= "throttling.bps=$limit:throttling.group=$storeid:";
6683 my $write_zeros = 1;
6684 if (PVE
::Storage
::volume_has_feature
($cfg, 'sparseinit', $volid)) {
6688 my $path = PVE
::Storage
::path
($cfg, $volid);
6690 print $fifofh "${map_opts}format=$d->{format}:${write_zeros}:$d->{devname}=$path\n";
6692 print "map '$d->{devname}' to '$path' (write zeros = ${write_zeros})\n";
6695 $fh->seek(0, 0) || die "seek failed - $!\n";
6697 my $cookie = { netcount
=> 0 };
6698 while (defined(my $line = <$fh>)) {
6699 $new_conf_raw .= restore_update_config_line
(
6716 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6717 local $SIG{ALRM
} = sub { die "got timeout\n"; };
6719 $oldtimeout = alarm($timeout);
6726 if ($line =~ m/^DEV:\sdev_id=(\d+)\ssize:\s(\d+)\sdevname:\s(\S+)$/) {
6727 my ($dev_id, $size, $devname) = ($1, $2, $3);
6728 $devinfo->{$devname} = { size
=> $size, dev_id
=> $dev_id };
6729 } elsif ($line =~ m/^CTIME: /) {
6730 # we correctly received the vma config, so we can disable
6731 # the timeout now for disk allocation (set to 10 minutes, so
6732 # that we always timeout if something goes wrong)
6735 print $fifofh "done\n";
6736 my $tmp = $oldtimeout || 0;
6737 $oldtimeout = undef;
6744 print "restore vma archive: $dbg_cmdstring\n";
6745 run_command
($commands, input
=> $input, outfunc
=> $parser, afterfork
=> $openfifo);
6749 alarm($oldtimeout) if $oldtimeout;
6751 $restore_deactivate_volumes->($cfg, $devinfo);
6753 close($fifofh) if $fifofh;
6758 $restore_destroy_volumes->($cfg, $devinfo);
6762 PVE
::Tools
::file_set_contents
($conffile, $new_conf_raw);
6764 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6766 eval { rescan
($vmid, 1); };
6769 PVE
::AccessControl
::add_vm_to_pool
($vmid, $opts->{pool
}) if $opts->{pool
};
6772 sub restore_tar_archive
{
6773 my ($archive, $vmid, $user, $opts) = @_;
6775 if ($archive ne '-') {
6776 my $firstfile = tar_archive_read_firstfile
($archive);
6777 die "ERROR: file '$archive' does not look like a QemuServer vzdump backup\n"
6778 if $firstfile ne 'qemu-server.conf';
6781 my $storecfg = PVE
::Storage
::config
();
6783 # avoid zombie disks when restoring over an existing VM -> cleanup first
6784 # pass keep_empty_config=1 to keep the config (thus VMID) reserved for us
6785 # skiplock=1 because qmrestore has set the 'create' lock itself already
6786 my $vmcfgfn = PVE
::QemuConfig-
>config_file($vmid);
6787 destroy_vm
($storecfg, $vmid, 1, { lock => 'restore' }) if -f
$vmcfgfn;
6789 my $tocmd = "/usr/lib/qemu-server/qmextract";
6791 $tocmd .= " --storage " . PVE
::Tools
::shellquote
($opts->{storage
}) if $opts->{storage
};
6792 $tocmd .= " --pool " . PVE
::Tools
::shellquote
($opts->{pool
}) if $opts->{pool
};
6793 $tocmd .= ' --prealloc' if $opts->{prealloc
};
6794 $tocmd .= ' --info' if $opts->{info
};
6796 # tar option "xf" does not autodetect compression when read from STDIN,
6797 # so we pipe to zcat
6798 my $cmd = "zcat -f|tar xf " . PVE
::Tools
::shellquote
($archive) . " " .
6799 PVE
::Tools
::shellquote
("--to-command=$tocmd");
6801 my $tmpdir = "/var/tmp/vzdumptmp$$";
6804 local $ENV{VZDUMP_TMPDIR
} = $tmpdir;
6805 local $ENV{VZDUMP_VMID
} = $vmid;
6806 local $ENV{VZDUMP_USER
} = $user;
6808 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6809 my $new_conf_raw = '';
6811 # disable interrupts (always do cleanups)
6815 local $SIG{HUP
} = sub { print STDERR
"got interrupt - ignored\n"; };
6823 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6825 if ($archive eq '-') {
6826 print "extracting archive from STDIN\n";
6827 run_command
($cmd, input
=> "<&STDIN");
6829 print "extracting archive '$archive'\n";
6833 return if $opts->{info
};
6837 my $statfile = "$tmpdir/qmrestore.stat";
6838 if (my $fd = IO
::File-
>new($statfile, "r")) {
6839 while (defined (my $line = <$fd>)) {
6840 if ($line =~ m/vzdump:([^\s:]*):(\S+)$/) {
6841 $map->{$1} = $2 if $1;
6843 print STDERR
"unable to parse line in statfile - $line\n";
6849 my $confsrc = "$tmpdir/qemu-server.conf";
6851 my $srcfd = IO
::File-
>new($confsrc, "r") || die "unable to open file '$confsrc'\n";
6853 my $cookie = { netcount
=> 0 };
6854 while (defined (my $line = <$srcfd>)) {
6855 $new_conf_raw .= restore_update_config_line
(
6866 tar_restore_cleanup
($storecfg, "$tmpdir/qmrestore.stat") if !$opts->{info
};
6872 PVE
::Tools
::file_set_contents
($conffile, $new_conf_raw);
6874 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6876 eval { rescan
($vmid, 1); };
6880 sub foreach_storage_used_by_vm
{
6881 my ($conf, $func) = @_;
6885 PVE
::QemuConfig-
>foreach_volume($conf, sub {
6886 my ($ds, $drive) = @_;
6887 return if drive_is_cdrom
($drive);
6889 my $volid = $drive->{file
};
6891 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
6892 $sidhash->{$sid} = $sid if $sid;
6895 foreach my $sid (sort keys %$sidhash) {
6900 my $qemu_snap_storage = {
6903 sub do_snapshots_with_qemu
{
6904 my ($storecfg, $volid) = @_;
6906 my $storage_name = PVE
::Storage
::parse_volume_id
($volid);
6907 my $scfg = $storecfg->{ids
}->{$storage_name};
6908 die "could not find storage '$storage_name'\n" if !defined($scfg);
6910 if ($qemu_snap_storage->{$scfg->{type
}} && !$scfg->{krbd
}){
6914 if ($volid =~ m/\.(qcow2|qed)$/){
6921 sub qga_check_running
{
6922 my ($vmid, $nowarn) = @_;
6924 eval { mon_cmd
($vmid, "guest-ping", timeout
=> 3); };
6926 warn "Qemu Guest Agent is not running - $@" if !$nowarn;
6932 sub template_create
{
6933 my ($vmid, $conf, $disk) = @_;
6935 my $storecfg = PVE
::Storage
::config
();
6937 PVE
::QemuConfig-
>foreach_volume($conf, sub {
6938 my ($ds, $drive) = @_;
6940 return if drive_is_cdrom
($drive);
6941 return if $disk && $ds ne $disk;
6943 my $volid = $drive->{file
};
6944 return if !PVE
::Storage
::volume_has_feature
($storecfg, 'template', $volid);
6946 my $voliddst = PVE
::Storage
::vdisk_create_base
($storecfg, $volid);
6947 $drive->{file
} = $voliddst;
6948 $conf->{$ds} = print_drive
($drive);
6949 PVE
::QemuConfig-
>write_config($vmid, $conf);
6953 sub convert_iscsi_path
{
6956 if ($path =~ m
|^iscsi
://([^/]+)/([^/]+)/(.+)$|) {
6961 my $initiator_name = get_initiator_name
();
6963 return "file.driver=iscsi,file.transport=tcp,file.initiator-name=$initiator_name,".
6964 "file.portal=$portal,file.target=$target,file.lun=$lun,driver=raw";
6967 die "cannot convert iscsi path '$path', unkown format\n";
6970 sub qemu_img_convert
{
6971 my ($src_volid, $dst_volid, $size, $snapname, $is_zero_initialized) = @_;
6973 my $storecfg = PVE
::Storage
::config
();
6974 my ($src_storeid, $src_volname) = PVE
::Storage
::parse_volume_id
($src_volid, 1);
6975 my ($dst_storeid, $dst_volname) = PVE
::Storage
::parse_volume_id
($dst_volid, 1);
6977 die "destination '$dst_volid' is not a valid volid form qemu-img convert\n" if !$dst_storeid;
6981 my $src_is_iscsi = 0;
6985 PVE
::Storage
::activate_volumes
($storecfg, [$src_volid], $snapname);
6986 my $src_scfg = PVE
::Storage
::storage_config
($storecfg, $src_storeid);
6987 $src_format = qemu_img_format
($src_scfg, $src_volname);
6988 $src_path = PVE
::Storage
::path
($storecfg, $src_volid, $snapname);
6989 $src_is_iscsi = ($src_path =~ m
|^iscsi
://|);
6990 $cachemode = 'none' if $src_scfg->{type
} eq 'zfspool';
6991 } elsif (-f
$src_volid) {
6992 $src_path = $src_volid;
6993 if ($src_path =~ m/\.($PVE::QemuServer::Drive::QEMU_FORMAT_RE)$/) {
6998 die "source '$src_volid' is not a valid volid nor path for qemu-img convert\n" if !$src_path;
7000 my $dst_scfg = PVE
::Storage
::storage_config
($storecfg, $dst_storeid);
7001 my $dst_format = qemu_img_format
($dst_scfg, $dst_volname);
7002 my $dst_path = PVE
::Storage
::path
($storecfg, $dst_volid);
7003 my $dst_is_iscsi = ($dst_path =~ m
|^iscsi
://|);
7006 push @$cmd, '/usr/bin/qemu-img', 'convert', '-p', '-n';
7007 push @$cmd, '-l', "snapshot.name=$snapname"
7008 if $snapname && $src_format && $src_format eq "qcow2";
7009 push @$cmd, '-t', 'none' if $dst_scfg->{type
} eq 'zfspool';
7010 push @$cmd, '-T', $cachemode if defined($cachemode);
7012 if ($src_is_iscsi) {
7013 push @$cmd, '--image-opts';
7014 $src_path = convert_iscsi_path
($src_path);
7015 } elsif ($src_format) {
7016 push @$cmd, '-f', $src_format;
7019 if ($dst_is_iscsi) {
7020 push @$cmd, '--target-image-opts';
7021 $dst_path = convert_iscsi_path
($dst_path);
7023 push @$cmd, '-O', $dst_format;
7026 push @$cmd, $src_path;
7028 if (!$dst_is_iscsi && $is_zero_initialized) {
7029 push @$cmd, "zeroinit:$dst_path";
7031 push @$cmd, $dst_path;
7036 if($line =~ m/\((\S+)\/100\
%\)/){
7038 my $transferred = int($size * $percent / 100);
7039 my $total_h = render_bytes
($size, 1);
7040 my $transferred_h = render_bytes
($transferred, 1);
7042 print "transferred $transferred_h of $total_h ($percent%)\n";
7047 eval { run_command
($cmd, timeout
=> undef, outfunc
=> $parser); };
7049 die "copy failed: $err" if $err;
7052 sub qemu_img_format
{
7053 my ($scfg, $volname) = @_;
7055 if ($scfg->{path
} && $volname =~ m/\.($PVE::QemuServer::Drive::QEMU_FORMAT_RE)$/) {
7062 sub qemu_drive_mirror
{
7063 my ($vmid, $drive, $dst_volid, $vmiddst, $is_zero_initialized, $jobs, $completion, $qga, $bwlimit, $src_bitmap) = @_;
7065 $jobs = {} if !$jobs;
7069 $jobs->{"drive-$drive"} = {};
7071 if ($dst_volid =~ /^nbd:/) {
7072 $qemu_target = $dst_volid;
7075 my $storecfg = PVE
::Storage
::config
();
7076 my ($dst_storeid, $dst_volname) = PVE
::Storage
::parse_volume_id
($dst_volid);
7078 my $dst_scfg = PVE
::Storage
::storage_config
($storecfg, $dst_storeid);
7080 $format = qemu_img_format
($dst_scfg, $dst_volname);
7082 my $dst_path = PVE
::Storage
::path
($storecfg, $dst_volid);
7084 $qemu_target = $is_zero_initialized ?
"zeroinit:$dst_path" : $dst_path;
7087 my $opts = { timeout
=> 10, device
=> "drive-$drive", mode
=> "existing", sync
=> "full", target
=> $qemu_target };
7088 $opts->{format
} = $format if $format;
7090 if (defined($src_bitmap)) {
7091 $opts->{sync
} = 'incremental';
7092 $opts->{bitmap
} = $src_bitmap;
7093 print "drive mirror re-using dirty bitmap '$src_bitmap'\n";
7096 if (defined($bwlimit)) {
7097 $opts->{speed
} = $bwlimit * 1024;
7098 print "drive mirror is starting for drive-$drive with bandwidth limit: ${bwlimit} KB/s\n";
7100 print "drive mirror is starting for drive-$drive\n";
7103 # if a job already runs for this device we get an error, catch it for cleanup
7104 eval { mon_cmd
($vmid, "drive-mirror", %$opts); };
7106 eval { PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs) };
7108 die "mirroring error: $err\n";
7111 qemu_drive_mirror_monitor
($vmid, $vmiddst, $jobs, $completion, $qga);
7114 # $completion can be either
7115 # 'complete': wait until all jobs are ready, block-job-complete them (default)
7116 # 'cancel': wait until all jobs are ready, block-job-cancel them
7117 # 'skip': wait until all jobs are ready, return with block jobs in ready state
7118 # 'auto': wait until all jobs disappear, only use for jobs which complete automatically
7119 sub qemu_drive_mirror_monitor
{
7120 my ($vmid, $vmiddst, $jobs, $completion, $qga, $op) = @_;
7122 $completion //= 'complete';
7126 my $err_complete = 0;
7128 my $starttime = time ();
7130 die "block job ('$op') timed out\n" if $err_complete > 300;
7132 my $stats = mon_cmd
($vmid, "query-block-jobs");
7135 my $running_jobs = {};
7136 for my $stat (@$stats) {
7137 next if $stat->{type
} ne $op;
7138 $running_jobs->{$stat->{device
}} = $stat;
7141 my $readycounter = 0;
7143 for my $job_id (sort keys %$jobs) {
7144 my $job = $running_jobs->{$job_id};
7146 my $vanished = !defined($job);
7147 my $complete = defined($jobs->{$job_id}->{complete
}) && $vanished;
7148 if($complete || ($vanished && $completion eq 'auto')) {
7149 print "$job_id: $op-job finished\n";
7150 delete $jobs->{$job_id};
7154 die "$job_id: '$op' has been cancelled\n" if !defined($job);
7156 my $busy = $job->{busy
};
7157 my $ready = $job->{ready
};
7158 if (my $total = $job->{len
}) {
7159 my $transferred = $job->{offset
} || 0;
7160 my $remaining = $total - $transferred;
7161 my $percent = sprintf "%.2f", ($transferred * 100 / $total);
7163 my $duration = $ctime - $starttime;
7164 my $total_h = render_bytes
($total, 1);
7165 my $transferred_h = render_bytes
($transferred, 1);
7167 my $status = sprintf(
7168 "transferred $transferred_h of $total_h ($percent%%) in %s",
7169 render_duration
($duration),
7174 $status .= ", still busy"; # shouldn't even happen? but mirror is weird
7176 $status .= ", ready";
7179 print "$job_id: $status\n" if !$jobs->{$job_id}->{ready
};
7180 $jobs->{$job_id}->{ready
} = $ready;
7183 $readycounter++ if $job->{ready
};
7186 last if scalar(keys %$jobs) == 0;
7188 if ($readycounter == scalar(keys %$jobs)) {
7189 print "all '$op' jobs are ready\n";
7191 # do the complete later (or has already been done)
7192 last if $completion eq 'skip' || $completion eq 'auto';
7194 if ($vmiddst && $vmiddst != $vmid) {
7195 my $agent_running = $qga && qga_check_running
($vmid);
7196 if ($agent_running) {
7197 print "freeze filesystem\n";
7198 eval { mon_cmd
($vmid, "guest-fsfreeze-freeze"); };
7200 print "suspend vm\n";
7201 eval { PVE
::QemuServer
::vm_suspend
($vmid, 1); };
7204 # if we clone a disk for a new target vm, we don't switch the disk
7205 PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs);
7207 if ($agent_running) {
7208 print "unfreeze filesystem\n";
7209 eval { mon_cmd
($vmid, "guest-fsfreeze-thaw"); };
7211 print "resume vm\n";
7212 eval { PVE
::QemuServer
::vm_resume
($vmid, 1, 1); };
7218 for my $job_id (sort keys %$jobs) {
7219 # try to switch the disk if source and destination are on the same guest
7220 print "$job_id: Completing block job_id...\n";
7223 if ($completion eq 'complete') {
7224 $op = 'block-job-complete';
7225 } elsif ($completion eq 'cancel') {
7226 $op = 'block-job-cancel';
7228 die "invalid completion value: $completion\n";
7230 eval { mon_cmd
($vmid, $op, device
=> $job_id) };
7231 if ($@ =~ m/cannot be completed/) {
7232 print "$job_id: block job cannot be completed, trying again.\n";
7235 print "$job_id: Completed successfully.\n";
7236 $jobs->{$job_id}->{complete
} = 1;
7247 eval { PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs) };
7248 die "block job ($op) error: $err";
7252 sub qemu_blockjobs_cancel
{
7253 my ($vmid, $jobs) = @_;
7255 foreach my $job (keys %$jobs) {
7256 print "$job: Cancelling block job\n";
7257 eval { mon_cmd
($vmid, "block-job-cancel", device
=> $job); };
7258 $jobs->{$job}->{cancel
} = 1;
7262 my $stats = mon_cmd
($vmid, "query-block-jobs");
7264 my $running_jobs = {};
7265 foreach my $stat (@$stats) {
7266 $running_jobs->{$stat->{device
}} = $stat;
7269 foreach my $job (keys %$jobs) {
7271 if (defined($jobs->{$job}->{cancel
}) && !defined($running_jobs->{$job})) {
7272 print "$job: Done.\n";
7273 delete $jobs->{$job};
7277 last if scalar(keys %$jobs) == 0;
7284 my ($storecfg, $vmid, $running, $drivename, $drive, $snapname,
7285 $newvmid, $storage, $format, $full, $newvollist, $jobs, $completion, $qga, $bwlimit, $conf) = @_;
7290 print "create linked clone of drive $drivename ($drive->{file})\n";
7291 $newvolid = PVE
::Storage
::vdisk_clone
($storecfg, $drive->{file
}, $newvmid, $snapname);
7292 push @$newvollist, $newvolid;
7295 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($drive->{file
});
7296 $storeid = $storage if $storage;
7298 my $dst_format = resolve_dst_disk_format
($storecfg, $storeid, $volname, $format);
7300 print "create full clone of drive $drivename ($drive->{file})\n";
7303 if (drive_is_cloudinit
($drive)) {
7304 $name = "vm-$newvmid-cloudinit";
7305 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
7306 if ($scfg->{path
}) {
7307 $name .= ".$dst_format";
7310 $size = PVE
::QemuServer
::Cloudinit
::CLOUDINIT_DISK_SIZE
;
7311 } elsif ($drivename eq 'efidisk0') {
7312 $size = get_efivars_size
($conf);
7314 ($size) = PVE
::Storage
::volume_size_info
($storecfg, $drive->{file
}, 10);
7316 $newvolid = PVE
::Storage
::vdisk_alloc
(
7317 $storecfg, $storeid, $newvmid, $dst_format, $name, ($size/1024)
7319 push @$newvollist, $newvolid;
7321 PVE
::Storage
::activate_volumes
($storecfg, [$newvolid]);
7323 if (drive_is_cloudinit
($drive)) {
7324 # when cloning multiple disks (e.g. during clone_vm) it might be the last disk
7325 # if this is the case, we have to complete any block-jobs still there from
7326 # previous drive-mirrors
7327 if (($completion eq 'complete') && (scalar(keys %$jobs) > 0)) {
7328 qemu_drive_mirror_monitor
($vmid, $newvmid, $jobs, $completion, $qga);
7333 my $sparseinit = PVE
::Storage
::volume_has_feature
($storecfg, 'sparseinit', $newvolid);
7334 if (!$running || $snapname) {
7335 # TODO: handle bwlimits
7336 if ($drivename eq 'efidisk0') {
7337 # the relevant data on the efidisk may be smaller than the source
7338 # e.g. on RBD/ZFS, so we use dd to copy only the amount
7339 # that is given by the OVMF_VARS.fd
7340 my $src_path = PVE
::Storage
::path
($storecfg, $drive->{file
});
7341 my $dst_path = PVE
::Storage
::path
($storecfg, $newvolid);
7343 # better for Ceph if block size is not too small, see bug #3324
7346 run_command
(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=$bs", "osize=$size",
7347 "if=$src_path", "of=$dst_path"]);
7349 qemu_img_convert
($drive->{file
}, $newvolid, $size, $snapname, $sparseinit);
7353 my $kvmver = get_running_qemu_version
($vmid);
7354 if (!min_version
($kvmver, 2, 7)) {
7355 die "drive-mirror with iothread requires qemu version 2.7 or higher\n"
7356 if $drive->{iothread
};
7359 qemu_drive_mirror
($vmid, $drivename, $newvolid, $newvmid, $sparseinit, $jobs,
7360 $completion, $qga, $bwlimit);
7365 my ($size) = eval { PVE
::Storage
::volume_size_info
($storecfg, $newvolid, 10) };
7368 $disk->{format
} = undef;
7369 $disk->{file
} = $newvolid;
7370 $disk->{size
} = $size if defined($size);
7375 sub get_running_qemu_version
{
7377 my $res = mon_cmd
($vmid, "query-version");
7378 return "$res->{qemu}->{major}.$res->{qemu}->{minor}";
7381 sub qemu_use_old_bios_files
{
7382 my ($machine_type) = @_;
7384 return if !$machine_type;
7386 my $use_old_bios_files = undef;
7388 if ($machine_type =~ m/^(\S+)\.pxe$/) {
7390 $use_old_bios_files = 1;
7392 my $version = extract_version
($machine_type, kvm_user_version
());
7393 # Note: kvm version < 2.4 use non-efi pxe files, and have problems when we
7394 # load new efi bios files on migration. So this hack is required to allow
7395 # live migration from qemu-2.2 to qemu-2.4, which is sometimes used when
7396 # updrading from proxmox-ve-3.X to proxmox-ve 4.0
7397 $use_old_bios_files = !min_version
($version, 2, 4);
7400 return ($use_old_bios_files, $machine_type);
7403 sub get_efivars_size
{
7405 my $arch = get_vm_arch
($conf);
7406 my (undef, $ovmf_vars) = get_ovmf_files
($arch);
7407 die "uefi vars image '$ovmf_vars' not found\n" if ! -f
$ovmf_vars;
7408 return -s
$ovmf_vars;
7411 sub update_efidisk_size
{
7414 return if !defined($conf->{efidisk0
});
7416 my $disk = PVE
::QemuServer
::parse_drive
('efidisk0', $conf->{efidisk0
});
7417 $disk->{size
} = get_efivars_size
($conf);
7418 $conf->{efidisk0
} = print_drive
($disk);
7423 sub create_efidisk
($$$$$) {
7424 my ($storecfg, $storeid, $vmid, $fmt, $arch) = @_;
7426 my (undef, $ovmf_vars) = get_ovmf_files
($arch);
7427 die "EFI vars default image not found\n" if ! -f
$ovmf_vars;
7429 my $vars_size_b = -s
$ovmf_vars;
7430 my $vars_size = PVE
::Tools
::convert_size
($vars_size_b, 'b' => 'kb');
7431 my $volid = PVE
::Storage
::vdisk_alloc
($storecfg, $storeid, $vmid, $fmt, undef, $vars_size);
7432 PVE
::Storage
::activate_volumes
($storecfg, [$volid]);
7434 qemu_img_convert
($ovmf_vars, $volid, $vars_size_b, undef, 0);
7435 my ($size) = PVE
::Storage
::volume_size_info
($storecfg, $volid, 3);
7437 return ($volid, $size/1024);
7440 sub vm_iothreads_list
{
7443 my $res = mon_cmd
($vmid, 'query-iothreads');
7446 foreach my $iothread (@$res) {
7447 $iothreads->{ $iothread->{id
} } = $iothread->{"thread-id"};
7454 my ($conf, $drive) = @_;
7458 if (!$conf->{scsihw
} || ($conf->{scsihw
} =~ m/^lsi/)) {
7460 } elsif ($conf->{scsihw
} && ($conf->{scsihw
} eq 'virtio-scsi-single')) {
7466 my $controller = int($drive->{index} / $maxdev);
7467 my $controller_prefix = ($conf->{scsihw
} && $conf->{scsihw
} eq 'virtio-scsi-single')
7471 return ($maxdev, $controller, $controller_prefix);
7474 sub windows_version
{
7477 return 0 if !$ostype;
7481 if($ostype eq 'wxp' || $ostype eq 'w2k3' || $ostype eq 'w2k') {
7483 } elsif($ostype eq 'w2k8' || $ostype eq 'wvista') {
7485 } elsif ($ostype =~ m/^win(\d+)$/) {
7492 sub resolve_dst_disk_format
{
7493 my ($storecfg, $storeid, $src_volname, $format) = @_;
7494 my ($defFormat, $validFormats) = PVE
::Storage
::storage_default_format
($storecfg, $storeid);
7497 # if no target format is specified, use the source disk format as hint
7499 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
7500 $format = qemu_img_format
($scfg, $src_volname);
7506 # test if requested format is supported - else use default
7507 my $supported = grep { $_ eq $format } @$validFormats;
7508 $format = $defFormat if !$supported;
7512 # NOTE: if this logic changes, please update docs & possibly gui logic
7513 sub find_vmstate_storage
{
7514 my ($conf, $storecfg) = @_;
7516 # first, return storage from conf if set
7517 return $conf->{vmstatestorage
} if $conf->{vmstatestorage
};
7519 my ($target, $shared, $local);
7521 foreach_storage_used_by_vm
($conf, sub {
7523 my $scfg = PVE
::Storage
::storage_config
($storecfg, $sid);
7524 my $dst = $scfg->{shared
} ? \
$shared : \
$local;
7525 $$dst = $sid if !$$dst || $scfg->{path
}; # prefer file based storage
7528 # second, use shared storage where VM has at least one disk
7529 # third, use local storage where VM has at least one disk
7530 # fall back to local storage
7531 $target = $shared // $local // 'local';
7537 my ($uuid, $uuid_str);
7538 UUID
::generate
($uuid);
7539 UUID
::unparse
($uuid, $uuid_str);
7543 sub generate_smbios1_uuid
{
7544 return "uuid=".generate_uuid
();
7550 mon_cmd
($vmid, 'nbd-server-stop');
7553 sub create_reboot_request
{
7555 open(my $fh, '>', "/run/qemu-server/$vmid.reboot")
7556 or die "failed to create reboot trigger file: $!\n";
7560 sub clear_reboot_request
{
7562 my $path = "/run/qemu-server/$vmid.reboot";
7565 $res = unlink($path);
7566 die "could not remove reboot request for $vmid: $!"
7567 if !$res && $! != POSIX
::ENOENT
;
7572 sub bootorder_from_legacy
{
7573 my ($conf, $bootcfg) = @_;
7575 my $boot = $bootcfg->{legacy
} || $boot_fmt->{legacy
}->{default};
7576 my $bootindex_hash = {};
7578 foreach my $o (split(//, $boot)) {
7579 $bootindex_hash->{$o} = $i*100;
7585 PVE
::QemuConfig-
>foreach_volume($conf, sub {
7586 my ($ds, $drive) = @_;
7588 if (drive_is_cdrom
($drive, 1)) {
7589 if ($bootindex_hash->{d
}) {
7590 $bootorder->{$ds} = $bootindex_hash->{d
};
7591 $bootindex_hash->{d
} += 1;
7593 } elsif ($bootindex_hash->{c
}) {
7594 $bootorder->{$ds} = $bootindex_hash->{c
}
7595 if $conf->{bootdisk
} && $conf->{bootdisk
} eq $ds;
7596 $bootindex_hash->{c
} += 1;
7600 if ($bootindex_hash->{n
}) {
7601 for (my $i = 0; $i < $MAX_NETS; $i++) {
7602 my $netname = "net$i";
7603 next if !$conf->{$netname};
7604 $bootorder->{$netname} = $bootindex_hash->{n
};
7605 $bootindex_hash->{n
} += 1;
7612 # Generate default device list for 'boot: order=' property. Matches legacy
7613 # default boot order, but with explicit device names. This is important, since
7614 # the fallback for when neither 'order' nor the old format is specified relies
7615 # on 'bootorder_from_legacy' above, and it would be confusing if this diverges.
7616 sub get_default_bootdevices
{
7622 my $first = PVE
::QemuServer
::Drive
::resolve_first_disk
($conf, 0);
7623 push @ret, $first if $first;
7626 $first = PVE
::QemuServer
::Drive
::resolve_first_disk
($conf, 1);
7627 push @ret, $first if $first;
7630 for (my $i = 0; $i < $MAX_NETS; $i++) {
7631 my $netname = "net$i";
7632 next if !$conf->{$netname};
7633 push @ret, $netname;
7640 sub device_bootorder
{
7643 return bootorder_from_legacy
($conf) if !defined($conf->{boot
});
7645 my $boot = parse_property_string
($boot_fmt, $conf->{boot
});
7648 if (!defined($boot) || $boot->{legacy
}) {
7649 $bootorder = bootorder_from_legacy
($conf, $boot);
7650 } elsif ($boot->{order
}) {
7651 my $i = 100; # start at 100 to allow user to insert devices before us with -args
7652 for my $dev (PVE
::Tools
::split_list
($boot->{order
})) {
7653 $bootorder->{$dev} = $i++;
7660 sub register_qmeventd_handle
{
7664 my $peer = "/var/run/qmeventd.sock";
7669 $fh = IO
::Socket
::UNIX-
>new(Peer
=> $peer, Blocking
=> 0, Timeout
=> 1);
7671 if ($! != EINTR
&& $! != EAGAIN
) {
7672 die "unable to connect to qmeventd socket (vmid: $vmid) - $!\n";
7675 die "unable to connect to qmeventd socket (vmid: $vmid) - timeout "
7676 . "after $count retries\n";
7681 # send handshake to mark VM as backing up
7682 print $fh to_json
({vzdump
=> {vmid
=> "$vmid"}});
7684 # return handle to be closed later when inhibit is no longer required
7688 # bash completion helper
7690 sub complete_backup_archives
{
7691 my ($cmdname, $pname, $cvalue) = @_;
7693 my $cfg = PVE
::Storage
::config
();
7697 if ($cvalue =~ m/^([^:]+):/) {
7701 my $data = PVE
::Storage
::template_list
($cfg, $storeid, 'backup');
7704 foreach my $id (keys %$data) {
7705 foreach my $item (@{$data->{$id}}) {
7706 next if $item->{format
} !~ m/^vma\.(${\PVE::Storage::Plugin::COMPRESSOR_RE})$/;
7707 push @$res, $item->{volid
} if defined($item->{volid
});
7714 my $complete_vmid_full = sub {
7717 my $idlist = vmstatus
();
7721 foreach my $id (keys %$idlist) {
7722 my $d = $idlist->{$id};
7723 if (defined($running)) {
7724 next if $d->{template
};
7725 next if $running && $d->{status
} ne 'running';
7726 next if !$running && $d->{status
} eq 'running';
7735 return &$complete_vmid_full();
7738 sub complete_vmid_stopped
{
7739 return &$complete_vmid_full(0);
7742 sub complete_vmid_running
{
7743 return &$complete_vmid_full(1);
7746 sub complete_storage
{
7748 my $cfg = PVE
::Storage
::config
();
7749 my $ids = $cfg->{ids
};
7752 foreach my $sid (keys %$ids) {
7753 next if !PVE
::Storage
::storage_check_enabled
($cfg, $sid, undef, 1);
7754 next if !$ids->{$sid}->{content
}->{images
};
7761 sub complete_migration_storage
{
7762 my ($cmd, $param, $current_value, $all_args) = @_;
7764 my $targetnode = @$all_args[1];
7766 my $cfg = PVE
::Storage
::config
();
7767 my $ids = $cfg->{ids
};
7770 foreach my $sid (keys %$ids) {
7771 next if !PVE
::Storage
::storage_check_enabled
($cfg, $sid, $targetnode, 1);
7772 next if !$ids->{$sid}->{content
}->{images
};
7781 my $qmpstatus = eval {
7782 PVE
::QemuConfig
::assert_config_exists_on_node
($vmid);
7783 mon_cmd
($vmid, "query-status");
7786 return $qmpstatus && $qmpstatus->{status
} eq "paused";
7789 sub check_volume_storage_type
{
7790 my ($storecfg, $vol) = @_;
7792 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($vol);
7793 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
7794 my ($vtype) = PVE
::Storage
::parse_volname
($storecfg, $vol);
7796 die "storage '$storeid' does not support content-type '$vtype'\n"
7797 if !$scfg->{content
}->{$vtype};