]> git.proxmox.com Git - pve-docs.git/blame_incremental - qm.conf.5-opts.adoc
certs: improve wording and styling
[pve-docs.git] / qm.conf.5-opts.adoc
... / ...
CommitLineData
1`acpi`: `<boolean>` ('default =' `1`)::
2
3Enable/disable ACPI.
4
5`agent`: `[enabled=]<1|0> [,fstrim_cloned_disks=<1|0>] [,type=<virtio|isa>]` ::
6
7Enable/disable Qemu GuestAgent and its properties.
8
9`enabled`=`<boolean>` ('default =' `0`);;
10
11Enable/disable Qemu GuestAgent.
12
13`fstrim_cloned_disks`=`<boolean>` ('default =' `0`);;
14
15Run fstrim after cloning/moving a disk.
16
17`type`=`<isa | virtio>` ('default =' `virtio`);;
18
19Select the agent type
20
21`arch`: `<aarch64 | x86_64>` ::
22
23Virtual processor architecture. Defaults to the host.
24
25`args`: `<string>` ::
26
27Arbitrary arguments passed to kvm, for example:
28+
29args: -no-reboot -no-hpet
30+
31NOTE: this option is for experts only.
32
33`audio0`: `device=<ich9-intel-hda|intel-hda|AC97> [,driver=<spice>]` ::
34
35Configure a audio device, useful in combination with QXL/Spice.
36
37`device`=`<AC97 | ich9-intel-hda | intel-hda>` ;;
38
39Configure an audio device.
40
41`driver`=`<spice>` ('default =' `spice`);;
42
43Driver backend for the audio device.
44
45`autostart`: `<boolean>` ('default =' `0`)::
46
47Automatic restart after crash (currently ignored).
48
49`balloon`: `<integer> (0 - N)` ::
50
51Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
52
53`bios`: `<ovmf | seabios>` ('default =' `seabios`)::
54
55Select BIOS implementation.
56
57`boot`: `[[legacy=]<[acdn]{1,4}>] [,order=<device[;device...]>]` ::
58
59Specify guest boot order. Use with 'order=', usage with no key or 'legacy=' is deprecated.
60
61`legacy`=`<[acdn]{1,4}>` ('default =' `cdn`);;
62
63Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n). Deprecated, use 'order=' instead.
64
65`order`=`<device[;device...]>` ;;
66
67The guest will attempt to boot from devices in the order they appear here.
68+
69Disks, optical drives and passed-through storage USB devices will be directly
70booted from, NICs will load PXE, and PCIe devices will either behave like disks
71(e.g. NVMe) or load an option ROM (e.g. RAID controller, hardware NIC).
72+
73Note that only devices in this list will be marked as bootable and thus loaded
74by the guest firmware (BIOS/UEFI). If you require multiple disks for booting
75(e.g. software-raid), you need to specify all of them here.
76+
77Overrides the deprecated 'legacy=[acdn]*' value when given.
78
79`bootdisk`: `(ide|sata|scsi|virtio)\d+` ::
80
81Enable booting from specified disk. Deprecated: Use 'boot: order=foo;bar' instead.
82
83`cdrom`: `<volume>` ::
84
85This is an alias for option -ide2
86
87`cicustom`: `[meta=<volume>] [,network=<volume>] [,user=<volume>]` ::
88
89cloud-init: Specify custom files to replace the automatically generated ones at start.
90
91`meta`=`<volume>` ;;
92
93Specify a custom file containing all meta data passed to the VM via"
94 ." cloud-init. This is provider specific meaning configdrive2 and nocloud differ.
95
96`network`=`<volume>` ;;
97
98Specify a custom file containing all network data passed to the VM via cloud-init.
99
100`user`=`<volume>` ;;
101
102Specify a custom file containing all user data passed to the VM via cloud-init.
103
104`cipassword`: `<string>` ::
105
106cloud-init: Password to assign the user. Using this is generally not recommended. Use ssh keys instead. Also note that older cloud-init versions do not support hashed passwords.
107
108`citype`: `<configdrive2 | nocloud>` ::
109
110Specifies the cloud-init configuration format. The default depends on the configured operating system type (`ostype`. We use the `nocloud` format for Linux, and `configdrive2` for windows.
111
112`ciuser`: `<string>` ::
113
114cloud-init: User name to change ssh keys and password for instead of the image's configured default user.
115
116`cores`: `<integer> (1 - N)` ('default =' `1`)::
117
118The number of cores per socket.
119
120`cpu`: `[[cputype=]<string>] [,flags=<+FLAG[;-FLAG...]>] [,hidden=<1|0>] [,hv-vendor-id=<vendor-id>] [,phys-bits=<8-64|host>] [,reported-model=<enum>]` ::
121
122Emulated CPU type.
123
124`cputype`=`<string>` ('default =' `kvm64`);;
125
126Emulated CPU type. Can be default or custom name (custom model names must be prefixed with 'custom-').
127
128`flags`=`<+FLAG[;-FLAG...]>` ;;
129
130List of additional CPU flags separated by ';'. Use '+FLAG' to enable, '-FLAG' to disable a flag. Custom CPU models can specify any flag supported by QEMU/KVM, VM-specific flags must be from the following set for security reasons: pcid, spec-ctrl, ibpb, ssbd, virt-ssbd, amd-ssbd, amd-no-ssb, pdpe1gb, md-clear, hv-tlbflush, hv-evmcs, aes.
131
132`hidden`=`<boolean>` ('default =' `0`);;
133
134Do not identify as a KVM virtual machine.
135
136`hv-vendor-id`=`<vendor-id>` ;;
137
138The Hyper-V vendor ID. Some drivers or programs inside Windows guests need a specific ID.
139
140`phys-bits`=`<8-64|host>` ;;
141
142The physical memory address bits that are reported to the guest OS. Should be smaller or equal to the host's. Set to 'host' to use value from host CPU, but note that doing so will break live migration to CPUs with other values.
143
144`reported-model`=`<486 | Broadwell | Broadwell-IBRS | Broadwell-noTSX | Broadwell-noTSX-IBRS | Cascadelake-Server | Cascadelake-Server-noTSX | Conroe | EPYC | EPYC-IBPB | EPYC-Rome | Haswell | Haswell-IBRS | Haswell-noTSX | Haswell-noTSX-IBRS | Icelake-Client | Icelake-Client-noTSX | Icelake-Server | Icelake-Server-noTSX | IvyBridge | IvyBridge-IBRS | KnightsMill | Nehalem | Nehalem-IBRS | Opteron_G1 | Opteron_G2 | Opteron_G3 | Opteron_G4 | Opteron_G5 | Penryn | SandyBridge | SandyBridge-IBRS | Skylake-Client | Skylake-Client-IBRS | Skylake-Client-noTSX-IBRS | Skylake-Server | Skylake-Server-IBRS | Skylake-Server-noTSX-IBRS | Westmere | Westmere-IBRS | athlon | core2duo | coreduo | host | kvm32 | kvm64 | max | pentium | pentium2 | pentium3 | phenom | qemu32 | qemu64>` ('default =' `kvm64`);;
145
146CPU model and vendor to report to the guest. Must be a QEMU/KVM supported model. Only valid for custom CPU model definitions, default models will always report themselves to the guest OS.
147
148`cpulimit`: `<number> (0 - 128)` ('default =' `0`)::
149
150Limit of CPU usage.
151+
152NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.
153
154`cpuunits`: `<integer> (2 - 262144)` ('default =' `1024`)::
155
156CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.
157
158`description`: `<string>` ::
159
160Description for the VM. Only used on the configuration web interface. This is saved as comment inside the configuration file.
161
162`efidisk0`: `[file=]<volume> [,format=<enum>] [,size=<DiskSize>]` ::
163
164Configure a Disk for storing EFI vars
165
166`file`=`<volume>` ;;
167
168The drive's backing volume.
169
170`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
171
172The drive's backing file's data format.
173
174`size`=`<DiskSize>` ;;
175
176Disk size. This is purely informational and has no effect.
177
178`freeze`: `<boolean>` ::
179
180Freeze CPU at startup (use 'c' monitor command to start execution).
181
182`hookscript`: `<string>` ::
183
184Script that will be executed during various steps in the vms lifetime.
185
186`hostpci[n]`: `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,legacy-igd=<1|0>] [,mdev=<string>] [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,x-vga=<1|0>]` ::
187
188Map host PCI devices into guest.
189+
190NOTE: This option allows direct access to host hardware. So it is no longer
191possible to migrate such machines - use with special care.
192+
193CAUTION: Experimental! User reported problems with this option.
194
195`host`=`<HOSTPCIID[;HOSTPCIID2...]>` ;;
196
197Host PCI device pass through. The PCI ID of a host's PCI device or a list
198of PCI virtual functions of the host. HOSTPCIID syntax is:
199+
200'bus:dev.func' (hexadecimal numbers)
201+
202You can us the 'lspci' command to list existing PCI devices.
203
204`legacy-igd`=`<boolean>` ('default =' `0`);;
205
206Pass this device in legacy IGD mode, making it the primary and exclusive graphics device in the VM. Requires 'pc-i440fx' machine type and VGA set to 'none'.
207
208`mdev`=`<string>` ;;
209
210The type of mediated device to use.
211An instance of this type will be created on startup of the VM and
212will be cleaned up when the VM stops.
213
214`pcie`=`<boolean>` ('default =' `0`);;
215
216Choose the PCI-express bus (needs the 'q35' machine model).
217
218`rombar`=`<boolean>` ('default =' `1`);;
219
220Specify whether or not the device's ROM will be visible in the guest's memory map.
221
222`romfile`=`<string>` ;;
223
224Custom pci device rom filename (must be located in /usr/share/kvm/).
225
226`x-vga`=`<boolean>` ('default =' `0`);;
227
228Enable vfio-vga device support.
229
230`hotplug`: `<string>` ('default =' `network,disk,usb`)::
231
232Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.
233
234`hugepages`: `<1024 | 2 | any>` ::
235
236Enable/disable hugepages memory.
237
238`ide[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
239
240Use volume as IDE hard disk or CD-ROM (n is 0 to 3).
241
242`aio`=`<native | threads>` ;;
243
244AIO type to use.
245
246`backup`=`<boolean>` ;;
247
248Whether the drive should be included when making backups.
249
250`bps`=`<bps>` ;;
251
252Maximum r/w speed in bytes per second.
253
254`bps_max_length`=`<seconds>` ;;
255
256Maximum length of I/O bursts in seconds.
257
258`bps_rd`=`<bps>` ;;
259
260Maximum read speed in bytes per second.
261
262`bps_rd_max_length`=`<seconds>` ;;
263
264Maximum length of read I/O bursts in seconds.
265
266`bps_wr`=`<bps>` ;;
267
268Maximum write speed in bytes per second.
269
270`bps_wr_max_length`=`<seconds>` ;;
271
272Maximum length of write I/O bursts in seconds.
273
274`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
275
276The drive's cache mode
277
278`cyls`=`<integer>` ;;
279
280Force the drive's physical geometry to have a specific cylinder count.
281
282`detect_zeroes`=`<boolean>` ;;
283
284Controls whether to detect and try to optimize writes of zeroes.
285
286`discard`=`<ignore | on>` ;;
287
288Controls whether to pass discard/trim requests to the underlying storage.
289
290`file`=`<volume>` ;;
291
292The drive's backing volume.
293
294`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
295
296The drive's backing file's data format.
297
298`heads`=`<integer>` ;;
299
300Force the drive's physical geometry to have a specific head count.
301
302`iops`=`<iops>` ;;
303
304Maximum r/w I/O in operations per second.
305
306`iops_max`=`<iops>` ;;
307
308Maximum unthrottled r/w I/O pool in operations per second.
309
310`iops_max_length`=`<seconds>` ;;
311
312Maximum length of I/O bursts in seconds.
313
314`iops_rd`=`<iops>` ;;
315
316Maximum read I/O in operations per second.
317
318`iops_rd_max`=`<iops>` ;;
319
320Maximum unthrottled read I/O pool in operations per second.
321
322`iops_rd_max_length`=`<seconds>` ;;
323
324Maximum length of read I/O bursts in seconds.
325
326`iops_wr`=`<iops>` ;;
327
328Maximum write I/O in operations per second.
329
330`iops_wr_max`=`<iops>` ;;
331
332Maximum unthrottled write I/O pool in operations per second.
333
334`iops_wr_max_length`=`<seconds>` ;;
335
336Maximum length of write I/O bursts in seconds.
337
338`mbps`=`<mbps>` ;;
339
340Maximum r/w speed in megabytes per second.
341
342`mbps_max`=`<mbps>` ;;
343
344Maximum unthrottled r/w pool in megabytes per second.
345
346`mbps_rd`=`<mbps>` ;;
347
348Maximum read speed in megabytes per second.
349
350`mbps_rd_max`=`<mbps>` ;;
351
352Maximum unthrottled read pool in megabytes per second.
353
354`mbps_wr`=`<mbps>` ;;
355
356Maximum write speed in megabytes per second.
357
358`mbps_wr_max`=`<mbps>` ;;
359
360Maximum unthrottled write pool in megabytes per second.
361
362`media`=`<cdrom | disk>` ('default =' `disk`);;
363
364The drive's media type.
365
366`model`=`<model>` ;;
367
368The drive's reported model name, url-encoded, up to 40 bytes long.
369
370`replicate`=`<boolean>` ('default =' `1`);;
371
372Whether the drive should considered for replication jobs.
373
374`rerror`=`<ignore | report | stop>` ;;
375
376Read error action.
377
378`secs`=`<integer>` ;;
379
380Force the drive's physical geometry to have a specific sector count.
381
382`serial`=`<serial>` ;;
383
384The drive's reported serial number, url-encoded, up to 20 bytes long.
385
386`shared`=`<boolean>` ('default =' `0`);;
387
388Mark this locally-managed volume as available on all nodes.
389+
390WARNING: This option does not share the volume automatically, it assumes it is shared already!
391
392`size`=`<DiskSize>` ;;
393
394Disk size. This is purely informational and has no effect.
395
396`snapshot`=`<boolean>` ;;
397
398Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
399
400`ssd`=`<boolean>` ;;
401
402Whether to expose this drive as an SSD, rather than a rotational hard disk.
403
404`trans`=`<auto | lba | none>` ;;
405
406Force disk geometry bios translation mode.
407
408`werror`=`<enospc | ignore | report | stop>` ;;
409
410Write error action.
411
412`wwn`=`<wwn>` ;;
413
414The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
415
416`ipconfig[n]`: `[gw=<GatewayIPv4>] [,gw6=<GatewayIPv6>] [,ip=<IPv4Format/CIDR>] [,ip6=<IPv6Format/CIDR>]` ::
417
418cloud-init: Specify IP addresses and gateways for the corresponding interface.
419+
420IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
421+
422The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit
423gateway should be provided.
424For IPv6 the special string 'auto' can be used to use stateless autoconfiguration.
425+
426If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using
427dhcp on IPv4.
428
429`gw`=`<GatewayIPv4>` ;;
430
431Default gateway for IPv4 traffic.
432+
433NOTE: Requires option(s): `ip`
434
435`gw6`=`<GatewayIPv6>` ;;
436
437Default gateway for IPv6 traffic.
438+
439NOTE: Requires option(s): `ip6`
440
441`ip`=`<IPv4Format/CIDR>` ('default =' `dhcp`);;
442
443IPv4 address in CIDR format.
444
445`ip6`=`<IPv6Format/CIDR>` ('default =' `dhcp`);;
446
447IPv6 address in CIDR format.
448
449`ivshmem`: `size=<integer> [,name=<string>]` ::
450
451Inter-VM shared memory. Useful for direct communication between VMs, or to the host.
452
453`name`=`<string>` ;;
454
455The name of the file. Will be prefixed with 'pve-shm-'. Default is the VMID. Will be deleted when the VM is stopped.
456
457`size`=`<integer> (1 - N)` ;;
458
459The size of the file in MB.
460
461`keephugepages`: `<boolean>` ('default =' `0`)::
462
463Use together with hugepages. If enabled, hugepages will not not be deleted after VM shutdown and can be used for subsequent starts.
464
465`keyboard`: `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ::
466
467Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.cfg' configuration file.It should not be necessary to set it.
468
469`kvm`: `<boolean>` ('default =' `1`)::
470
471Enable/disable KVM hardware virtualization.
472
473`localtime`: `<boolean>` ::
474
475Set the real time clock to local time. This is enabled by default if ostype indicates a Microsoft OS.
476
477`lock`: `<backup | clone | create | migrate | rollback | snapshot | snapshot-delete | suspended | suspending>` ::
478
479Lock/unlock the VM.
480
481`machine`: `(pc|pc(-i440fx)?-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|q35|pc-q35-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|virt(?:-\d+(\.\d+)+)?(\+pve\d+)?)` ::
482
483Specifies the Qemu machine type.
484
485`memory`: `<integer> (16 - N)` ('default =' `512`)::
486
487Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
488
489`migrate_downtime`: `<number> (0 - N)` ('default =' `0.1`)::
490
491Set maximum tolerated downtime (in seconds) for migrations.
492
493`migrate_speed`: `<integer> (0 - N)` ('default =' `0`)::
494
495Set maximum speed (in MB/s) for migrations. Value 0 is no limit.
496
497`name`: `<string>` ::
498
499Set a name for the VM. Only used on the configuration web interface.
500
501`nameserver`: `<string>` ::
502
503cloud-init: Sets DNS server IP address for a container. Create will'
504 .' automatically use the setting from the host if neither searchdomain nor nameserver'
505 .' are set.
506
507`net[n]`: `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,mtu=<integer>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
508
509Specify network devices.
510
511`bridge`=`<bridge>` ;;
512
513Bridge to attach the network device to. The Proxmox VE standard bridge
514is called 'vmbr0'.
515+
516If you do not specify a bridge, we create a kvm user (NATed) network
517device, which provides DHCP and DNS services. The following addresses
518are used:
519+
520 10.0.2.2 Gateway
521 10.0.2.3 DNS Server
522 10.0.2.4 SMB Server
523+
524The DHCP server assign addresses to the guest starting from 10.0.2.15.
525
526`firewall`=`<boolean>` ;;
527
528Whether this interface should be protected by the firewall.
529
530`link_down`=`<boolean>` ;;
531
532Whether this interface should be disconnected (like pulling the plug).
533
534`macaddr`=`<XX:XX:XX:XX:XX:XX>` ;;
535
536A common MAC address with the I/G (Individual/Group) bit not set.
537
538`model`=`<e1000 | e1000-82540em | e1000-82544gc | e1000-82545em | i82551 | i82557b | i82559er | ne2k_isa | ne2k_pci | pcnet | rtl8139 | virtio | vmxnet3>` ;;
539
540Network Card Model. The 'virtio' model provides the best performance with very low CPU overhead. If your guest does not support this driver, it is usually best to use 'e1000'.
541
542`mtu`=`<integer> (1 - 65520)` ;;
543
544Force MTU, for VirtIO only. Set to '1' to use the bridge MTU
545
546`queues`=`<integer> (0 - 16)` ;;
547
548Number of packet queues to be used on the device.
549
550`rate`=`<number> (0 - N)` ;;
551
552Rate limit in mbps (megabytes per second) as floating point number.
553
554`tag`=`<integer> (1 - 4094)` ;;
555
556VLAN tag to apply to packets on this interface.
557
558`trunks`=`<vlanid[;vlanid...]>` ;;
559
560VLAN trunks to pass through this interface.
561
562`numa`: `<boolean>` ('default =' `0`)::
563
564Enable/disable NUMA.
565
566`numa[n]`: `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<number>] [,policy=<preferred|bind|interleave>]` ::
567
568NUMA topology.
569
570`cpus`=`<id[-id];...>` ;;
571
572CPUs accessing this NUMA node.
573
574`hostnodes`=`<id[-id];...>` ;;
575
576Host NUMA nodes to use.
577
578`memory`=`<number>` ;;
579
580Amount of memory this NUMA node provides.
581
582`policy`=`<bind | interleave | preferred>` ;;
583
584NUMA allocation policy.
585
586`onboot`: `<boolean>` ('default =' `0`)::
587
588Specifies whether a VM will be started during system bootup.
589
590`ostype`: `<l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win10 | win7 | win8 | wvista | wxp>` ::
591
592Specify guest operating system. This is used to enable special
593optimization/features for specific operating systems:
594+
595[horizontal]
596other;; unspecified OS
597wxp;; Microsoft Windows XP
598w2k;; Microsoft Windows 2000
599w2k3;; Microsoft Windows 2003
600w2k8;; Microsoft Windows 2008
601wvista;; Microsoft Windows Vista
602win7;; Microsoft Windows 7
603win8;; Microsoft Windows 8/2012/2012r2
604win10;; Microsoft Windows 10/2016
605l24;; Linux 2.4 Kernel
606l26;; Linux 2.6 - 5.X Kernel
607solaris;; Solaris/OpenSolaris/OpenIndiania kernel
608
609`parallel[n]`: `/dev/parport\d+|/dev/usb/lp\d+` ::
610
611Map host parallel devices (n is 0 to 2).
612+
613NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
614machines - use with special care.
615+
616CAUTION: Experimental! User reported problems with this option.
617
618`protection`: `<boolean>` ('default =' `0`)::
619
620Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.
621
622`reboot`: `<boolean>` ('default =' `1`)::
623
624Allow reboot. If set to '0' the VM exit on reboot.
625
626`rng0`: `[source=]</dev/urandom|/dev/random|/dev/hwrng> [,max_bytes=<integer>] [,period=<integer>]` ::
627
628Configure a VirtIO-based Random Number Generator.
629
630`max_bytes`=`<integer>` ('default =' `1024`);;
631
632Maximum bytes of entropy injected into the guest every 'period' milliseconds. Prefer a lower value when using /dev/random as source. Use 0 to disable limiting (potentially dangerous!).
633
634`period`=`<integer>` ('default =' `1000`);;
635
636Every 'period' milliseconds the entropy-injection quota is reset, allowing the guest to retrieve another 'max_bytes' of entropy.
637
638`source`=`</dev/hwrng | /dev/random | /dev/urandom>` ;;
639
640The file on the host to gather entropy from. In most cases /dev/urandom should be preferred over /dev/random to avoid entropy-starvation issues on the host. Using urandom does *not* decrease security in any meaningful way, as it's still seeded from real entropy, and the bytes provided will most likely be mixed with real entropy on the guest as well. /dev/hwrng can be used to pass through a hardware RNG from the host.
641
642`sata[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
643
644Use volume as SATA hard disk or CD-ROM (n is 0 to 5).
645
646`aio`=`<native | threads>` ;;
647
648AIO type to use.
649
650`backup`=`<boolean>` ;;
651
652Whether the drive should be included when making backups.
653
654`bps`=`<bps>` ;;
655
656Maximum r/w speed in bytes per second.
657
658`bps_max_length`=`<seconds>` ;;
659
660Maximum length of I/O bursts in seconds.
661
662`bps_rd`=`<bps>` ;;
663
664Maximum read speed in bytes per second.
665
666`bps_rd_max_length`=`<seconds>` ;;
667
668Maximum length of read I/O bursts in seconds.
669
670`bps_wr`=`<bps>` ;;
671
672Maximum write speed in bytes per second.
673
674`bps_wr_max_length`=`<seconds>` ;;
675
676Maximum length of write I/O bursts in seconds.
677
678`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
679
680The drive's cache mode
681
682`cyls`=`<integer>` ;;
683
684Force the drive's physical geometry to have a specific cylinder count.
685
686`detect_zeroes`=`<boolean>` ;;
687
688Controls whether to detect and try to optimize writes of zeroes.
689
690`discard`=`<ignore | on>` ;;
691
692Controls whether to pass discard/trim requests to the underlying storage.
693
694`file`=`<volume>` ;;
695
696The drive's backing volume.
697
698`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
699
700The drive's backing file's data format.
701
702`heads`=`<integer>` ;;
703
704Force the drive's physical geometry to have a specific head count.
705
706`iops`=`<iops>` ;;
707
708Maximum r/w I/O in operations per second.
709
710`iops_max`=`<iops>` ;;
711
712Maximum unthrottled r/w I/O pool in operations per second.
713
714`iops_max_length`=`<seconds>` ;;
715
716Maximum length of I/O bursts in seconds.
717
718`iops_rd`=`<iops>` ;;
719
720Maximum read I/O in operations per second.
721
722`iops_rd_max`=`<iops>` ;;
723
724Maximum unthrottled read I/O pool in operations per second.
725
726`iops_rd_max_length`=`<seconds>` ;;
727
728Maximum length of read I/O bursts in seconds.
729
730`iops_wr`=`<iops>` ;;
731
732Maximum write I/O in operations per second.
733
734`iops_wr_max`=`<iops>` ;;
735
736Maximum unthrottled write I/O pool in operations per second.
737
738`iops_wr_max_length`=`<seconds>` ;;
739
740Maximum length of write I/O bursts in seconds.
741
742`mbps`=`<mbps>` ;;
743
744Maximum r/w speed in megabytes per second.
745
746`mbps_max`=`<mbps>` ;;
747
748Maximum unthrottled r/w pool in megabytes per second.
749
750`mbps_rd`=`<mbps>` ;;
751
752Maximum read speed in megabytes per second.
753
754`mbps_rd_max`=`<mbps>` ;;
755
756Maximum unthrottled read pool in megabytes per second.
757
758`mbps_wr`=`<mbps>` ;;
759
760Maximum write speed in megabytes per second.
761
762`mbps_wr_max`=`<mbps>` ;;
763
764Maximum unthrottled write pool in megabytes per second.
765
766`media`=`<cdrom | disk>` ('default =' `disk`);;
767
768The drive's media type.
769
770`replicate`=`<boolean>` ('default =' `1`);;
771
772Whether the drive should considered for replication jobs.
773
774`rerror`=`<ignore | report | stop>` ;;
775
776Read error action.
777
778`secs`=`<integer>` ;;
779
780Force the drive's physical geometry to have a specific sector count.
781
782`serial`=`<serial>` ;;
783
784The drive's reported serial number, url-encoded, up to 20 bytes long.
785
786`shared`=`<boolean>` ('default =' `0`);;
787
788Mark this locally-managed volume as available on all nodes.
789+
790WARNING: This option does not share the volume automatically, it assumes it is shared already!
791
792`size`=`<DiskSize>` ;;
793
794Disk size. This is purely informational and has no effect.
795
796`snapshot`=`<boolean>` ;;
797
798Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
799
800`ssd`=`<boolean>` ;;
801
802Whether to expose this drive as an SSD, rather than a rotational hard disk.
803
804`trans`=`<auto | lba | none>` ;;
805
806Force disk geometry bios translation mode.
807
808`werror`=`<enospc | ignore | report | stop>` ;;
809
810Write error action.
811
812`wwn`=`<wwn>` ;;
813
814The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
815
816`scsi[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
817
818Use volume as SCSI hard disk or CD-ROM (n is 0 to 30).
819
820`aio`=`<native | threads>` ;;
821
822AIO type to use.
823
824`backup`=`<boolean>` ;;
825
826Whether the drive should be included when making backups.
827
828`bps`=`<bps>` ;;
829
830Maximum r/w speed in bytes per second.
831
832`bps_max_length`=`<seconds>` ;;
833
834Maximum length of I/O bursts in seconds.
835
836`bps_rd`=`<bps>` ;;
837
838Maximum read speed in bytes per second.
839
840`bps_rd_max_length`=`<seconds>` ;;
841
842Maximum length of read I/O bursts in seconds.
843
844`bps_wr`=`<bps>` ;;
845
846Maximum write speed in bytes per second.
847
848`bps_wr_max_length`=`<seconds>` ;;
849
850Maximum length of write I/O bursts in seconds.
851
852`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
853
854The drive's cache mode
855
856`cyls`=`<integer>` ;;
857
858Force the drive's physical geometry to have a specific cylinder count.
859
860`detect_zeroes`=`<boolean>` ;;
861
862Controls whether to detect and try to optimize writes of zeroes.
863
864`discard`=`<ignore | on>` ;;
865
866Controls whether to pass discard/trim requests to the underlying storage.
867
868`file`=`<volume>` ;;
869
870The drive's backing volume.
871
872`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
873
874The drive's backing file's data format.
875
876`heads`=`<integer>` ;;
877
878Force the drive's physical geometry to have a specific head count.
879
880`iops`=`<iops>` ;;
881
882Maximum r/w I/O in operations per second.
883
884`iops_max`=`<iops>` ;;
885
886Maximum unthrottled r/w I/O pool in operations per second.
887
888`iops_max_length`=`<seconds>` ;;
889
890Maximum length of I/O bursts in seconds.
891
892`iops_rd`=`<iops>` ;;
893
894Maximum read I/O in operations per second.
895
896`iops_rd_max`=`<iops>` ;;
897
898Maximum unthrottled read I/O pool in operations per second.
899
900`iops_rd_max_length`=`<seconds>` ;;
901
902Maximum length of read I/O bursts in seconds.
903
904`iops_wr`=`<iops>` ;;
905
906Maximum write I/O in operations per second.
907
908`iops_wr_max`=`<iops>` ;;
909
910Maximum unthrottled write I/O pool in operations per second.
911
912`iops_wr_max_length`=`<seconds>` ;;
913
914Maximum length of write I/O bursts in seconds.
915
916`iothread`=`<boolean>` ;;
917
918Whether to use iothreads for this drive
919
920`mbps`=`<mbps>` ;;
921
922Maximum r/w speed in megabytes per second.
923
924`mbps_max`=`<mbps>` ;;
925
926Maximum unthrottled r/w pool in megabytes per second.
927
928`mbps_rd`=`<mbps>` ;;
929
930Maximum read speed in megabytes per second.
931
932`mbps_rd_max`=`<mbps>` ;;
933
934Maximum unthrottled read pool in megabytes per second.
935
936`mbps_wr`=`<mbps>` ;;
937
938Maximum write speed in megabytes per second.
939
940`mbps_wr_max`=`<mbps>` ;;
941
942Maximum unthrottled write pool in megabytes per second.
943
944`media`=`<cdrom | disk>` ('default =' `disk`);;
945
946The drive's media type.
947
948`queues`=`<integer> (2 - N)` ;;
949
950Number of queues.
951
952`replicate`=`<boolean>` ('default =' `1`);;
953
954Whether the drive should considered for replication jobs.
955
956`rerror`=`<ignore | report | stop>` ;;
957
958Read error action.
959
960`scsiblock`=`<boolean>` ('default =' `0`);;
961
962whether to use scsi-block for full passthrough of host block device
963+
964WARNING: can lead to I/O errors in combination with low memory or high memory fragmentation on host
965
966`secs`=`<integer>` ;;
967
968Force the drive's physical geometry to have a specific sector count.
969
970`serial`=`<serial>` ;;
971
972The drive's reported serial number, url-encoded, up to 20 bytes long.
973
974`shared`=`<boolean>` ('default =' `0`);;
975
976Mark this locally-managed volume as available on all nodes.
977+
978WARNING: This option does not share the volume automatically, it assumes it is shared already!
979
980`size`=`<DiskSize>` ;;
981
982Disk size. This is purely informational and has no effect.
983
984`snapshot`=`<boolean>` ;;
985
986Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
987
988`ssd`=`<boolean>` ;;
989
990Whether to expose this drive as an SSD, rather than a rotational hard disk.
991
992`trans`=`<auto | lba | none>` ;;
993
994Force disk geometry bios translation mode.
995
996`werror`=`<enospc | ignore | report | stop>` ;;
997
998Write error action.
999
1000`wwn`=`<wwn>` ;;
1001
1002The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
1003
1004`scsihw`: `<lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single>` ('default =' `lsi`)::
1005
1006SCSI controller model
1007
1008`searchdomain`: `<string>` ::
1009
1010cloud-init: Sets DNS search domains for a container. Create will'
1011 .' automatically use the setting from the host if neither searchdomain nor nameserver'
1012 .' are set.
1013
1014`serial[n]`: `(/dev/.+|socket)` ::
1015
1016Create a serial device inside the VM (n is 0 to 3), and pass through a
1017host serial device (i.e. /dev/ttyS0), or create a unix socket on the
1018host side (use 'qm terminal' to open a terminal connection).
1019+
1020NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines -
1021use with special care.
1022+
1023CAUTION: Experimental! User reported problems with this option.
1024
1025`shares`: `<integer> (0 - 50000)` ('default =' `1000`)::
1026
1027Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.
1028
1029`smbios1`: `[base64=<1|0>] [,family=<Base64 encoded string>] [,manufacturer=<Base64 encoded string>] [,product=<Base64 encoded string>] [,serial=<Base64 encoded string>] [,sku=<Base64 encoded string>] [,uuid=<UUID>] [,version=<Base64 encoded string>]` ::
1030
1031Specify SMBIOS type 1 fields.
1032
1033`base64`=`<boolean>` ;;
1034
1035Flag to indicate that the SMBIOS values are base64 encoded
1036
1037`family`=`<Base64 encoded string>` ;;
1038
1039Set SMBIOS1 family string.
1040
1041`manufacturer`=`<Base64 encoded string>` ;;
1042
1043Set SMBIOS1 manufacturer.
1044
1045`product`=`<Base64 encoded string>` ;;
1046
1047Set SMBIOS1 product ID.
1048
1049`serial`=`<Base64 encoded string>` ;;
1050
1051Set SMBIOS1 serial number.
1052
1053`sku`=`<Base64 encoded string>` ;;
1054
1055Set SMBIOS1 SKU string.
1056
1057`uuid`=`<UUID>` ;;
1058
1059Set SMBIOS1 UUID.
1060
1061`version`=`<Base64 encoded string>` ;;
1062
1063Set SMBIOS1 version.
1064
1065`smp`: `<integer> (1 - N)` ('default =' `1`)::
1066
1067The number of CPUs. Please use option -sockets instead.
1068
1069`sockets`: `<integer> (1 - N)` ('default =' `1`)::
1070
1071The number of CPU sockets.
1072
1073`spice_enhancements`: `[foldersharing=<1|0>] [,videostreaming=<off|all|filter>]` ::
1074
1075Configure additional enhancements for SPICE.
1076
1077`foldersharing`=`<boolean>` ('default =' `0`);;
1078
1079Enable folder sharing via SPICE. Needs Spice-WebDAV daemon installed in the VM.
1080
1081`videostreaming`=`<all | filter | off>` ('default =' `off`);;
1082
1083Enable video streaming. Uses compression for detected video streams.
1084
1085`sshkeys`: `<string>` ::
1086
1087cloud-init: Setup public SSH keys (one key per line, OpenSSH format).
1088
1089`startdate`: `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` ('default =' `now`)::
1090
1091Set the initial date of the real time clock. Valid format for date are:'now' or '2006-06-17T16:01:21' or '2006-06-17'.
1092
1093`startup`: `[[order=]\d+] [,up=\d+] [,down=\d+] ` ::
1094
1095Startup and shutdown behavior. Order is a non-negative number defining the general startup order. Shutdown in done with reverse ordering. Additionally you can set the 'up' or 'down' delay in seconds, which specifies a delay to wait before the next VM is started or stopped.
1096
1097`tablet`: `<boolean>` ('default =' `1`)::
1098
1099Enable/disable the USB tablet device. This device is usually needed to allow absolute mouse positioning with VNC. Else the mouse runs out of sync with normal VNC clients. If you're running lots of console-only guests on one host, you may consider disabling this to save some context switches. This is turned off by default if you use spice (`qm set <vmid> --vga qxl`).
1100
1101`tags`: `<string>` ::
1102
1103Tags of the VM. This is only meta information.
1104
1105`tdf`: `<boolean>` ('default =' `0`)::
1106
1107Enable/disable time drift fix.
1108
1109`template`: `<boolean>` ('default =' `0`)::
1110
1111Enable/disable Template.
1112
1113`unused[n]`: `[file=]<volume>` ::
1114
1115Reference to unused volumes. This is used internally, and should not be modified manually.
1116
1117`file`=`<volume>` ;;
1118
1119The drive's backing volume.
1120
1121`usb[n]`: `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
1122
1123Configure an USB device (n is 0 to 4).
1124
1125`host`=`<HOSTUSBDEVICE|spice>` ;;
1126
1127The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
1128+
1129 'bus-port(.port)*' (decimal numbers) or
1130 'vendor_id:product_id' (hexadeciaml numbers) or
1131 'spice'
1132+
1133You can use the 'lsusb -t' command to list existing usb devices.
1134+
1135NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
1136machines - use with special care.
1137+
1138The value 'spice' can be used to add a usb redirection devices for spice.
1139
1140`usb3`=`<boolean>` ('default =' `0`);;
1141
1142Specifies whether if given host option is a USB3 device or port.
1143
1144`vcpus`: `<integer> (1 - N)` ('default =' `0`)::
1145
1146Number of hotplugged vcpus.
1147
1148`vga`: `[[type=]<enum>] [,memory=<integer>]` ::
1149
1150Configure the VGA Hardware. If you want to use high resolution modes (>= 1280x1024x16) you may need to increase the vga memory option. Since QEMU 2.9 the default VGA display type is 'std' for all OS types besides some Windows versions (XP and older) which use 'cirrus'. The 'qxl' option enables the SPICE display server. For win* OS you can select how many independent displays you want, Linux guests can add displays them self.
1151You can also run without any graphic card, using a serial device as terminal.
1152
1153`memory`=`<integer> (4 - 512)` ;;
1154
1155Sets the VGA memory (in MiB). Has no effect with serial display.
1156
1157`type`=`<cirrus | none | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | virtio | vmware>` ('default =' `std`);;
1158
1159Select the VGA type.
1160
1161`virtio[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
1162
1163Use volume as VIRTIO hard disk (n is 0 to 15).
1164
1165`aio`=`<native | threads>` ;;
1166
1167AIO type to use.
1168
1169`backup`=`<boolean>` ;;
1170
1171Whether the drive should be included when making backups.
1172
1173`bps`=`<bps>` ;;
1174
1175Maximum r/w speed in bytes per second.
1176
1177`bps_max_length`=`<seconds>` ;;
1178
1179Maximum length of I/O bursts in seconds.
1180
1181`bps_rd`=`<bps>` ;;
1182
1183Maximum read speed in bytes per second.
1184
1185`bps_rd_max_length`=`<seconds>` ;;
1186
1187Maximum length of read I/O bursts in seconds.
1188
1189`bps_wr`=`<bps>` ;;
1190
1191Maximum write speed in bytes per second.
1192
1193`bps_wr_max_length`=`<seconds>` ;;
1194
1195Maximum length of write I/O bursts in seconds.
1196
1197`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
1198
1199The drive's cache mode
1200
1201`cyls`=`<integer>` ;;
1202
1203Force the drive's physical geometry to have a specific cylinder count.
1204
1205`detect_zeroes`=`<boolean>` ;;
1206
1207Controls whether to detect and try to optimize writes of zeroes.
1208
1209`discard`=`<ignore | on>` ;;
1210
1211Controls whether to pass discard/trim requests to the underlying storage.
1212
1213`file`=`<volume>` ;;
1214
1215The drive's backing volume.
1216
1217`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
1218
1219The drive's backing file's data format.
1220
1221`heads`=`<integer>` ;;
1222
1223Force the drive's physical geometry to have a specific head count.
1224
1225`iops`=`<iops>` ;;
1226
1227Maximum r/w I/O in operations per second.
1228
1229`iops_max`=`<iops>` ;;
1230
1231Maximum unthrottled r/w I/O pool in operations per second.
1232
1233`iops_max_length`=`<seconds>` ;;
1234
1235Maximum length of I/O bursts in seconds.
1236
1237`iops_rd`=`<iops>` ;;
1238
1239Maximum read I/O in operations per second.
1240
1241`iops_rd_max`=`<iops>` ;;
1242
1243Maximum unthrottled read I/O pool in operations per second.
1244
1245`iops_rd_max_length`=`<seconds>` ;;
1246
1247Maximum length of read I/O bursts in seconds.
1248
1249`iops_wr`=`<iops>` ;;
1250
1251Maximum write I/O in operations per second.
1252
1253`iops_wr_max`=`<iops>` ;;
1254
1255Maximum unthrottled write I/O pool in operations per second.
1256
1257`iops_wr_max_length`=`<seconds>` ;;
1258
1259Maximum length of write I/O bursts in seconds.
1260
1261`iothread`=`<boolean>` ;;
1262
1263Whether to use iothreads for this drive
1264
1265`mbps`=`<mbps>` ;;
1266
1267Maximum r/w speed in megabytes per second.
1268
1269`mbps_max`=`<mbps>` ;;
1270
1271Maximum unthrottled r/w pool in megabytes per second.
1272
1273`mbps_rd`=`<mbps>` ;;
1274
1275Maximum read speed in megabytes per second.
1276
1277`mbps_rd_max`=`<mbps>` ;;
1278
1279Maximum unthrottled read pool in megabytes per second.
1280
1281`mbps_wr`=`<mbps>` ;;
1282
1283Maximum write speed in megabytes per second.
1284
1285`mbps_wr_max`=`<mbps>` ;;
1286
1287Maximum unthrottled write pool in megabytes per second.
1288
1289`media`=`<cdrom | disk>` ('default =' `disk`);;
1290
1291The drive's media type.
1292
1293`replicate`=`<boolean>` ('default =' `1`);;
1294
1295Whether the drive should considered for replication jobs.
1296
1297`rerror`=`<ignore | report | stop>` ;;
1298
1299Read error action.
1300
1301`secs`=`<integer>` ;;
1302
1303Force the drive's physical geometry to have a specific sector count.
1304
1305`serial`=`<serial>` ;;
1306
1307The drive's reported serial number, url-encoded, up to 20 bytes long.
1308
1309`shared`=`<boolean>` ('default =' `0`);;
1310
1311Mark this locally-managed volume as available on all nodes.
1312+
1313WARNING: This option does not share the volume automatically, it assumes it is shared already!
1314
1315`size`=`<DiskSize>` ;;
1316
1317Disk size. This is purely informational and has no effect.
1318
1319`snapshot`=`<boolean>` ;;
1320
1321Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
1322
1323`trans`=`<auto | lba | none>` ;;
1324
1325Force disk geometry bios translation mode.
1326
1327`werror`=`<enospc | ignore | report | stop>` ;;
1328
1329Write error action.
1330
1331`vmgenid`: `<UUID>` ('default =' `1 (autogenerated)`)::
1332
1333The VM generation ID (vmgenid) device exposes a 128-bit integer value identifier to the guest OS. This allows to notify the guest operating system when the virtual machine is executed with a different configuration (e.g. snapshot execution or creation from a template). The guest operating system notices the change, and is then able to react as appropriate by marking its copies of distributed databases as dirty, re-initializing its random number generator, etc.
1334Note that auto-creation only works when done through API/CLI create or update methods, but not when manually editing the config file.
1335
1336`vmstatestorage`: `<string>` ::
1337
1338Default storage for VM state volumes/files.
1339
1340`watchdog`: `[[model=]<i6300esb|ib700>] [,action=<enum>]` ::
1341
1342Create a virtual hardware watchdog device. Once enabled (by a guest action), the watchdog must be periodically polled by an agent inside the guest or else the watchdog will reset the guest (or execute the respective action specified)
1343
1344`action`=`<debug | none | pause | poweroff | reset | shutdown>` ;;
1345
1346The action to perform if after activation the guest fails to poll the watchdog in time.
1347
1348`model`=`<i6300esb | ib700>` ('default =' `i6300esb`);;
1349
1350Watchdog type to emulate.
1351