]> git.proxmox.com Git - pve-docs.git/blob - pveceph.adoc
pveceph: add section - Destroying Ceph OSDs
[pve-docs.git] / pveceph.adoc
1 [[chapter_pveceph]]
2 ifdef::manvolnum[]
3 pveceph(1)
4 ==========
5 :pve-toplevel:
6
7 NAME
8 ----
9
10 pveceph - Manage Ceph Services on Proxmox VE Nodes
11
12 SYNOPSIS
13 --------
14
15 include::pveceph.1-synopsis.adoc[]
16
17 DESCRIPTION
18 -----------
19 endif::manvolnum[]
20 ifndef::manvolnum[]
21 Manage Ceph Services on Proxmox VE Nodes
22 ========================================
23 :pve-toplevel:
24 endif::manvolnum[]
25
26 [thumbnail="screenshot/gui-ceph-status.png"]
27
28 {pve} unifies your compute and storage systems, i.e. you can use the same
29 physical nodes within a cluster for both computing (processing VMs and
30 containers) and replicated storage. The traditional silos of compute and
31 storage resources can be wrapped up into a single hyper-converged appliance.
32 Separate storage networks (SANs) and connections via network attached storages
33 (NAS) disappear. With the integration of Ceph, an open source software-defined
34 storage platform, {pve} has the ability to run and manage Ceph storage directly
35 on the hypervisor nodes.
36
37 Ceph is a distributed object store and file system designed to provide
38 excellent performance, reliability and scalability.
39
40 .Some advantages of Ceph on {pve} are:
41 - Easy setup and management with CLI and GUI support
42 - Thin provisioning
43 - Snapshots support
44 - Self healing
45 - Scalable to the exabyte level
46 - Setup pools with different performance and redundancy characteristics
47 - Data is replicated, making it fault tolerant
48 - Runs on economical commodity hardware
49 - No need for hardware RAID controllers
50 - Open source
51
52 For small to mid sized deployments, it is possible to install a Ceph server for
53 RADOS Block Devices (RBD) directly on your {pve} cluster nodes, see
54 xref:ceph_rados_block_devices[Ceph RADOS Block Devices (RBD)]. Recent
55 hardware has plenty of CPU power and RAM, so running storage services
56 and VMs on the same node is possible.
57
58 To simplify management, we provide 'pveceph' - a tool to install and
59 manage {ceph} services on {pve} nodes.
60
61 .Ceph consists of a couple of Daemons footnote:[Ceph intro http://docs.ceph.com/docs/luminous/start/intro/], for use as a RBD storage:
62 - Ceph Monitor (ceph-mon)
63 - Ceph Manager (ceph-mgr)
64 - Ceph OSD (ceph-osd; Object Storage Daemon)
65
66 TIP: We highly recommend to get familiar with Ceph's architecture
67 footnote:[Ceph architecture http://docs.ceph.com/docs/luminous/architecture/]
68 and vocabulary
69 footnote:[Ceph glossary http://docs.ceph.com/docs/luminous/glossary].
70
71
72 Precondition
73 ------------
74
75 To build a hyper-converged Proxmox + Ceph Cluster there should be at least
76 three (preferably) identical servers for the setup.
77
78 Check also the recommendations from
79 http://docs.ceph.com/docs/luminous/start/hardware-recommendations/[Ceph's website].
80
81 .CPU
82 Higher CPU core frequency reduce latency and should be preferred. As a simple
83 rule of thumb, you should assign a CPU core (or thread) to each Ceph service to
84 provide enough resources for stable and durable Ceph performance.
85
86 .Memory
87 Especially in a hyper-converged setup, the memory consumption needs to be
88 carefully monitored. In addition to the intended workload from virtual machines
89 and container, Ceph needs enough memory available to provide good and stable
90 performance. As a rule of thumb, for roughly 1 TiB of data, 1 GiB of memory
91 will be used by an OSD. OSD caching will use additional memory.
92
93 .Network
94 We recommend a network bandwidth of at least 10 GbE or more, which is used
95 exclusively for Ceph. A meshed network setup
96 footnote:[Full Mesh Network for Ceph {webwiki-url}Full_Mesh_Network_for_Ceph_Server]
97 is also an option if there are no 10 GbE switches available.
98
99 The volume of traffic, especially during recovery, will interfere with other
100 services on the same network and may even break the {pve} cluster stack.
101
102 Further, estimate your bandwidth needs. While one HDD might not saturate a 1 Gb
103 link, multiple HDD OSDs per node can, and modern NVMe SSDs will even saturate
104 10 Gbps of bandwidth quickly. Deploying a network capable of even more bandwith
105 will ensure that it isn't your bottleneck and won't be anytime soon, 25, 40 or
106 even 100 GBps are possible.
107
108 .Disks
109 When planning the size of your Ceph cluster, it is important to take the
110 recovery time into consideration. Especially with small clusters, the recovery
111 might take long. It is recommended that you use SSDs instead of HDDs in small
112 setups to reduce recovery time, minimizing the likelihood of a subsequent
113 failure event during recovery.
114
115 In general SSDs will provide more IOPs than spinning disks. This fact and the
116 higher cost may make a xref:pve_ceph_device_classes[class based] separation of
117 pools appealing. Another possibility to speedup OSDs is to use a faster disk
118 as journal or DB/**W**rite-**A**head-**L**og device, see
119 xref:pve_ceph_osds[creating Ceph OSDs]. If a faster disk is used for multiple
120 OSDs, a proper balance between OSD and WAL / DB (or journal) disk must be
121 selected, otherwise the faster disk becomes the bottleneck for all linked OSDs.
122
123 Aside from the disk type, Ceph best performs with an even sized and distributed
124 amount of disks per node. For example, 4 x 500 GB disks with in each node is
125 better than a mixed setup with a single 1 TB and three 250 GB disk.
126
127 One also need to balance OSD count and single OSD capacity. More capacity
128 allows to increase storage density, but it also means that a single OSD
129 failure forces ceph to recover more data at once.
130
131 .Avoid RAID
132 As Ceph handles data object redundancy and multiple parallel writes to disks
133 (OSDs) on its own, using a RAID controller normally doesn’t improve
134 performance or availability. On the contrary, Ceph is designed to handle whole
135 disks on it's own, without any abstraction in between. RAID controller are not
136 designed for the Ceph use case and may complicate things and sometimes even
137 reduce performance, as their write and caching algorithms may interfere with
138 the ones from Ceph.
139
140 WARNING: Avoid RAID controller, use host bus adapter (HBA) instead.
141
142 NOTE: Above recommendations should be seen as a rough guidance for choosing
143 hardware. Therefore, it is still essential to adapt it to your specific needs,
144 test your setup and monitor health and performance continuously.
145
146 [[pve_ceph_install_wizard]]
147 Initial Ceph installation & configuration
148 -----------------------------------------
149
150 [thumbnail="screenshot/gui-node-ceph-install.png"]
151
152 With {pve} you have the benefit of an easy to use installation wizard
153 for Ceph. Click on one of your cluster nodes and navigate to the Ceph
154 section in the menu tree. If Ceph is not already installed you will be
155 offered to do so now.
156
157 The wizard is divided into different sections, where each needs to be
158 finished successfully in order to use Ceph. After starting the installation
159 the wizard will download and install all required packages from {pve}'s ceph
160 repository.
161
162 After finishing the first step, you will need to create a configuration.
163 This step is only needed once per cluster, as this configuration is distributed
164 automatically to all remaining cluster members through {pve}'s clustered
165 xref:chapter_pmxcfs[configuration file system (pmxcfs)].
166
167 The configuration step includes the following settings:
168
169 * *Public Network:* You should setup a dedicated network for Ceph, this
170 setting is required. Separating your Ceph traffic is highly recommended,
171 because it could lead to troubles with other latency dependent services,
172 e.g., cluster communication may decrease Ceph's performance, if not done.
173
174 [thumbnail="screenshot/gui-node-ceph-install-wizard-step2.png"]
175
176 * *Cluster Network:* As an optional step you can go even further and
177 separate the xref:pve_ceph_osds[OSD] replication & heartbeat traffic
178 as well. This will relieve the public network and could lead to
179 significant performance improvements especially in big clusters.
180
181 You have two more options which are considered advanced and therefore
182 should only changed if you are an expert.
183
184 * *Number of replicas*: Defines the how often a object is replicated
185 * *Minimum replicas*: Defines the minimum number of required replicas
186 for I/O to be marked as complete.
187
188 Additionally you need to choose your first monitor node, this is required.
189
190 That's it, you should see a success page as the last step with further
191 instructions on how to go on. You are now prepared to start using Ceph,
192 even though you will need to create additional xref:pve_ceph_monitors[monitors],
193 create some xref:pve_ceph_osds[OSDs] and at least one xref:pve_ceph_pools[pool].
194
195 The rest of this chapter will guide you on how to get the most out of
196 your {pve} based Ceph setup, this will include aforementioned and
197 more like xref:pveceph_fs[CephFS] which is a very handy addition to your
198 new Ceph cluster.
199
200 [[pve_ceph_install]]
201 Installation of Ceph Packages
202 -----------------------------
203 Use {pve} Ceph installation wizard (recommended) or run the following
204 command on each node:
205
206 [source,bash]
207 ----
208 pveceph install
209 ----
210
211 This sets up an `apt` package repository in
212 `/etc/apt/sources.list.d/ceph.list` and installs the required software.
213
214
215 Creating initial Ceph configuration
216 -----------------------------------
217
218 [thumbnail="screenshot/gui-ceph-config.png"]
219
220 Use the {pve} Ceph installation wizard (recommended) or run the
221 following command on one node:
222
223 [source,bash]
224 ----
225 pveceph init --network 10.10.10.0/24
226 ----
227
228 This creates an initial configuration at `/etc/pve/ceph.conf` with a
229 dedicated network for ceph. That file is automatically distributed to
230 all {pve} nodes by using xref:chapter_pmxcfs[pmxcfs]. The command also
231 creates a symbolic link from `/etc/ceph/ceph.conf` pointing to that file.
232 So you can simply run Ceph commands without the need to specify a
233 configuration file.
234
235
236 [[pve_ceph_monitors]]
237 Creating Ceph Monitors
238 ----------------------
239
240 [thumbnail="screenshot/gui-ceph-monitor.png"]
241
242 The Ceph Monitor (MON)
243 footnote:[Ceph Monitor http://docs.ceph.com/docs/luminous/start/intro/]
244 maintains a master copy of the cluster map. For high availability you need to
245 have at least 3 monitors. One monitor will already be installed if you
246 used the installation wizard. You won't need more than 3 monitors as long
247 as your cluster is small to midsize, only really large clusters will
248 need more than that.
249
250 On each node where you want to place a monitor (three monitors are recommended),
251 create it by using the 'Ceph -> Monitor' tab in the GUI or run.
252
253
254 [source,bash]
255 ----
256 pveceph mon create
257 ----
258
259 This will also install the needed Ceph Manager ('ceph-mgr') by default. If you
260 do not want to install a manager, specify the '-exclude-manager' option.
261
262
263 [[pve_ceph_manager]]
264 Creating Ceph Manager
265 ----------------------
266
267 The Manager daemon runs alongside the monitors, providing an interface for
268 monitoring the cluster. Since the Ceph luminous release the
269 ceph-mgr footnote:[Ceph Manager http://docs.ceph.com/docs/luminous/mgr/] daemon
270 is required. During monitor installation the ceph manager will be installed as
271 well.
272
273 NOTE: It is recommended to install the Ceph Manager on the monitor nodes. For
274 high availability install more then one manager.
275
276 [source,bash]
277 ----
278 pveceph mgr create
279 ----
280
281
282 [[pve_ceph_osds]]
283 Creating Ceph OSDs
284 ------------------
285
286 [thumbnail="screenshot/gui-ceph-osd-status.png"]
287
288 via GUI or via CLI as follows:
289
290 [source,bash]
291 ----
292 pveceph osd create /dev/sd[X]
293 ----
294
295 TIP: We recommend a Ceph cluster size, starting with 12 OSDs, distributed evenly
296 among your, at least three nodes (4 OSDs on each node).
297
298 If the disk was used before (eg. ZFS/RAID/OSD), to remove partition table, boot
299 sector and any OSD leftover the following command should be sufficient.
300
301 [source,bash]
302 ----
303 ceph-volume lvm zap /dev/sd[X] --destroy
304 ----
305
306 WARNING: The above command will destroy data on the disk!
307
308 Ceph Bluestore
309 ~~~~~~~~~~~~~~
310
311 Starting with the Ceph Kraken release, a new Ceph OSD storage type was
312 introduced, the so called Bluestore
313 footnote:[Ceph Bluestore http://ceph.com/community/new-luminous-bluestore/].
314 This is the default when creating OSDs since Ceph Luminous.
315
316 [source,bash]
317 ----
318 pveceph osd create /dev/sd[X]
319 ----
320
321 .Block.db and block.wal
322
323 If you want to use a separate DB/WAL device for your OSDs, you can specify it
324 through the '-db_dev' and '-wal_dev' options. The WAL is placed with the DB, if not
325 specified separately.
326
327 [source,bash]
328 ----
329 pveceph osd create /dev/sd[X] -db_dev /dev/sd[Y] -wal_dev /dev/sd[Z]
330 ----
331
332 You can directly choose the size for those with the '-db_size' and '-wal_size'
333 paremeters respectively. If they are not given the following values (in order)
334 will be used:
335
336 * bluestore_block_{db,wal}_size from ceph configuration...
337 ** ... database, section 'osd'
338 ** ... database, section 'global'
339 ** ... file, section 'osd'
340 ** ... file, section 'global'
341 * 10% (DB)/1% (WAL) of OSD size
342
343 NOTE: The DB stores BlueStore’s internal metadata and the WAL is BlueStore’s
344 internal journal or write-ahead log. It is recommended to use a fast SSD or
345 NVRAM for better performance.
346
347
348 Ceph Filestore
349 ~~~~~~~~~~~~~~
350
351 Before Ceph Luminous, Filestore was used as default storage type for Ceph OSDs.
352 Starting with Ceph Nautilus, {pve} does not support creating such OSDs with
353 'pveceph' anymore. If you still want to create filestore OSDs, use
354 'ceph-volume' directly.
355
356 [source,bash]
357 ----
358 ceph-volume lvm create --filestore --data /dev/sd[X] --journal /dev/sd[Y]
359 ----
360
361 Destroying Ceph OSDs
362 --------------------
363
364 To remove an OSD via the GUI first select a {PVE} node in the tree view and go
365 to the **Ceph -> OSD** panel. Select the OSD to destroy. Next click the **OUT**
366 button. Once the OSD status changed from `in` to `out` click the **STOP**
367 button. As soon as the status changed from `up` to `down` select **Destroy**
368 from the `More` drop-down menu.
369
370 To remove an OSD via the CLI run the following commands.
371 [source,bash]
372 ----
373 ceph osd out <ID>
374 systemctl stop ceph-osd@<ID>.service
375 ----
376 NOTE: The first command instructs Ceph not to include the OSD in the data
377 distribution. The second command stops the OSD service. Until this time, no
378 data is lost.
379
380 The following command destroys the OSD. Specify the '-cleanup' option to
381 additionally destroy the partition table.
382 [source,bash]
383 ----
384 pveceph osd destroy <ID>
385 ----
386 WARNING: The above command will destroy data on the disk!
387
388
389 [[pve_ceph_pools]]
390 Creating Ceph Pools
391 -------------------
392
393 [thumbnail="screenshot/gui-ceph-pools.png"]
394
395 A pool is a logical group for storing objects. It holds **P**lacement
396 **G**roups (`PG`, `pg_num`), a collection of objects.
397
398 When no options are given, we set a default of **128 PGs**, a **size of 3
399 replicas** and a **min_size of 2 replicas** for serving objects in a degraded
400 state.
401
402 NOTE: The default number of PGs works for 2-5 disks. Ceph throws a
403 'HEALTH_WARNING' if you have too few or too many PGs in your cluster.
404
405 It is advised to calculate the PG number depending on your setup, you can find
406 the formula and the PG calculator footnote:[PG calculator
407 http://ceph.com/pgcalc/] online. While PGs can be increased later on, they can
408 never be decreased.
409
410
411 You can create pools through command line or on the GUI on each PVE host under
412 **Ceph -> Pools**.
413
414 [source,bash]
415 ----
416 pveceph pool create <name>
417 ----
418
419 If you would like to automatically also get a storage definition for your pool,
420 mark the checkbox "Add storages" in the GUI or use the command line option
421 '--add_storages' at pool creation.
422
423 Further information on Ceph pool handling can be found in the Ceph pool
424 operation footnote:[Ceph pool operation
425 http://docs.ceph.com/docs/luminous/rados/operations/pools/]
426 manual.
427
428 [[pve_ceph_device_classes]]
429 Ceph CRUSH & device classes
430 ---------------------------
431 The foundation of Ceph is its algorithm, **C**ontrolled **R**eplication
432 **U**nder **S**calable **H**ashing
433 (CRUSH footnote:[CRUSH https://ceph.com/wp-content/uploads/2016/08/weil-crush-sc06.pdf]).
434
435 CRUSH calculates where to store to and retrieve data from, this has the
436 advantage that no central index service is needed. CRUSH works with a map of
437 OSDs, buckets (device locations) and rulesets (data replication) for pools.
438
439 NOTE: Further information can be found in the Ceph documentation, under the
440 section CRUSH map footnote:[CRUSH map http://docs.ceph.com/docs/luminous/rados/operations/crush-map/].
441
442 This map can be altered to reflect different replication hierarchies. The object
443 replicas can be separated (eg. failure domains), while maintaining the desired
444 distribution.
445
446 A common use case is to use different classes of disks for different Ceph pools.
447 For this reason, Ceph introduced the device classes with luminous, to
448 accommodate the need for easy ruleset generation.
449
450 The device classes can be seen in the 'ceph osd tree' output. These classes
451 represent their own root bucket, which can be seen with the below command.
452
453 [source, bash]
454 ----
455 ceph osd crush tree --show-shadow
456 ----
457
458 Example output form the above command:
459
460 [source, bash]
461 ----
462 ID CLASS WEIGHT TYPE NAME
463 -16 nvme 2.18307 root default~nvme
464 -13 nvme 0.72769 host sumi1~nvme
465 12 nvme 0.72769 osd.12
466 -14 nvme 0.72769 host sumi2~nvme
467 13 nvme 0.72769 osd.13
468 -15 nvme 0.72769 host sumi3~nvme
469 14 nvme 0.72769 osd.14
470 -1 7.70544 root default
471 -3 2.56848 host sumi1
472 12 nvme 0.72769 osd.12
473 -5 2.56848 host sumi2
474 13 nvme 0.72769 osd.13
475 -7 2.56848 host sumi3
476 14 nvme 0.72769 osd.14
477 ----
478
479 To let a pool distribute its objects only on a specific device class, you need
480 to create a ruleset with the specific class first.
481
482 [source, bash]
483 ----
484 ceph osd crush rule create-replicated <rule-name> <root> <failure-domain> <class>
485 ----
486
487 [frame="none",grid="none", align="left", cols="30%,70%"]
488 |===
489 |<rule-name>|name of the rule, to connect with a pool (seen in GUI & CLI)
490 |<root>|which crush root it should belong to (default ceph root "default")
491 |<failure-domain>|at which failure-domain the objects should be distributed (usually host)
492 |<class>|what type of OSD backing store to use (eg. nvme, ssd, hdd)
493 |===
494
495 Once the rule is in the CRUSH map, you can tell a pool to use the ruleset.
496
497 [source, bash]
498 ----
499 ceph osd pool set <pool-name> crush_rule <rule-name>
500 ----
501
502 TIP: If the pool already contains objects, all of these have to be moved
503 accordingly. Depending on your setup this may introduce a big performance hit on
504 your cluster. As an alternative, you can create a new pool and move disks
505 separately.
506
507
508 Ceph Client
509 -----------
510
511 [thumbnail="screenshot/gui-ceph-log.png"]
512
513 You can then configure {pve} to use such pools to store VM or
514 Container images. Simply use the GUI too add a new `RBD` storage (see
515 section xref:ceph_rados_block_devices[Ceph RADOS Block Devices (RBD)]).
516
517 You also need to copy the keyring to a predefined location for an external Ceph
518 cluster. If Ceph is installed on the Proxmox nodes itself, then this will be
519 done automatically.
520
521 NOTE: The file name needs to be `<storage_id> + `.keyring` - `<storage_id>` is
522 the expression after 'rbd:' in `/etc/pve/storage.cfg` which is
523 `my-ceph-storage` in the following example:
524
525 [source,bash]
526 ----
527 mkdir /etc/pve/priv/ceph
528 cp /etc/ceph/ceph.client.admin.keyring /etc/pve/priv/ceph/my-ceph-storage.keyring
529 ----
530
531 [[pveceph_fs]]
532 CephFS
533 ------
534
535 Ceph provides also a filesystem running on top of the same object storage as
536 RADOS block devices do. A **M**eta**d**ata **S**erver (`MDS`) is used to map
537 the RADOS backed objects to files and directories, allowing to provide a
538 POSIX-compliant replicated filesystem. This allows one to have a clustered
539 highly available shared filesystem in an easy way if ceph is already used. Its
540 Metadata Servers guarantee that files get balanced out over the whole Ceph
541 cluster, this way even high load will not overload a single host, which can be
542 an issue with traditional shared filesystem approaches, like `NFS`, for
543 example.
544
545 [thumbnail="screenshot/gui-node-ceph-cephfs-panel.png"]
546
547 {pve} supports both, using an existing xref:storage_cephfs[CephFS as storage]
548 to save backups, ISO files or container templates and creating a
549 hyper-converged CephFS itself.
550
551
552 [[pveceph_fs_mds]]
553 Metadata Server (MDS)
554 ~~~~~~~~~~~~~~~~~~~~~
555
556 CephFS needs at least one Metadata Server to be configured and running to be
557 able to work. One can simply create one through the {pve} web GUI's `Node ->
558 CephFS` panel or on the command line with:
559
560 ----
561 pveceph mds create
562 ----
563
564 Multiple metadata servers can be created in a cluster. But with the default
565 settings only one can be active at any time. If an MDS, or its node, becomes
566 unresponsive (or crashes), another `standby` MDS will get promoted to `active`.
567 One can speed up the hand-over between the active and a standby MDS up by using
568 the 'hotstandby' parameter option on create, or if you have already created it
569 you may set/add:
570
571 ----
572 mds standby replay = true
573 ----
574
575 in the ceph.conf respective MDS section. With this enabled, this specific MDS
576 will always poll the active one, so that it can take over faster as it is in a
577 `warm` state. But naturally, the active polling will cause some additional
578 performance impact on your system and active `MDS`.
579
580 .Multiple Active MDS
581
582 Since Luminous (12.2.x) you can also have multiple active metadata servers
583 running, but this is normally only useful for a high count on parallel clients,
584 as else the `MDS` seldom is the bottleneck. If you want to set this up please
585 refer to the ceph documentation. footnote:[Configuring multiple active MDS
586 daemons http://docs.ceph.com/docs/luminous/cephfs/multimds/]
587
588 [[pveceph_fs_create]]
589 Create a CephFS
590 ~~~~~~~~~~~~~~~
591
592 With {pve}'s CephFS integration into you can create a CephFS easily over the
593 Web GUI, the CLI or an external API interface. Some prerequisites are required
594 for this to work:
595
596 .Prerequisites for a successful CephFS setup:
597 - xref:pve_ceph_install[Install Ceph packages], if this was already done some
598 time ago you might want to rerun it on an up to date system to ensure that
599 also all CephFS related packages get installed.
600 - xref:pve_ceph_monitors[Setup Monitors]
601 - xref:pve_ceph_monitors[Setup your OSDs]
602 - xref:pveceph_fs_mds[Setup at least one MDS]
603
604 After this got all checked and done you can simply create a CephFS through
605 either the Web GUI's `Node -> CephFS` panel or the command line tool `pveceph`,
606 for example with:
607
608 ----
609 pveceph fs create --pg_num 128 --add-storage
610 ----
611
612 This creates a CephFS named `'cephfs'' using a pool for its data named
613 `'cephfs_data'' with `128` placement groups and a pool for its metadata named
614 `'cephfs_metadata'' with one quarter of the data pools placement groups (`32`).
615 Check the xref:pve_ceph_pools[{pve} managed Ceph pool chapter] or visit the
616 Ceph documentation for more information regarding a fitting placement group
617 number (`pg_num`) for your setup footnote:[Ceph Placement Groups
618 http://docs.ceph.com/docs/luminous/rados/operations/placement-groups/].
619 Additionally, the `'--add-storage'' parameter will add the CephFS to the {pve}
620 storage configuration after it was created successfully.
621
622 Destroy CephFS
623 ~~~~~~~~~~~~~~
624
625 WARNING: Destroying a CephFS will render all its data unusable, this cannot be
626 undone!
627
628 If you really want to destroy an existing CephFS you first need to stop, or
629 destroy, all metadata servers (`M̀DS`). You can destroy them either over the Web
630 GUI or the command line interface, with:
631
632 ----
633 pveceph mds destroy NAME
634 ----
635 on each {pve} node hosting a MDS daemon.
636
637 Then, you can remove (destroy) CephFS by issuing a:
638
639 ----
640 ceph fs rm NAME --yes-i-really-mean-it
641 ----
642 on a single node hosting Ceph. After this you may want to remove the created
643 data and metadata pools, this can be done either over the Web GUI or the CLI
644 with:
645
646 ----
647 pveceph pool destroy NAME
648 ----
649
650
651 Ceph monitoring and troubleshooting
652 -----------------------------------
653 A good start is to continuosly monitor the ceph health from the start of
654 initial deployment. Either through the ceph tools itself, but also by accessing
655 the status through the {pve} link:api-viewer/index.html[API].
656
657 The following ceph commands below can be used to see if the cluster is healthy
658 ('HEALTH_OK'), if there are warnings ('HEALTH_WARN'), or even errors
659 ('HEALTH_ERR'). If the cluster is in an unhealthy state the status commands
660 below will also give you an overview of the current events and actions to take.
661
662 ----
663 # single time output
664 pve# ceph -s
665 # continuously output status changes (press CTRL+C to stop)
666 pve# ceph -w
667 ----
668
669 To get a more detailed view, every ceph service has a log file under
670 `/var/log/ceph/` and if there is not enough detail, the log level can be
671 adjusted footnote:[Ceph log and debugging http://docs.ceph.com/docs/luminous/rados/troubleshooting/log-and-debug/].
672
673 You can find more information about troubleshooting
674 footnote:[Ceph troubleshooting http://docs.ceph.com/docs/luminous/rados/troubleshooting/]
675 a Ceph cluster on the official website.
676
677
678 ifdef::manvolnum[]
679 include::pve-copyright.adoc[]
680 endif::manvolnum[]