]> git.proxmox.com Git - pve-docs.git/blob - qm.conf.5-opts.adoc
network: adapt apply config section to PVE 7
[pve-docs.git] / qm.conf.5-opts.adoc
1 `acpi`: `<boolean>` ('default =' `1`)::
2
3 Enable/disable ACPI.
4
5 `agent`: `[enabled=]<1|0> [,fstrim_cloned_disks=<1|0>] [,type=<virtio|isa>]` ::
6
7 Enable/disable communication with the Qemu Guest Agent and its properties.
8
9 `enabled`=`<boolean>` ('default =' `0`);;
10
11 Enable/disable communication with a Qemu Guest Agent (QGA) running in the VM.
12
13 `fstrim_cloned_disks`=`<boolean>` ('default =' `0`);;
14
15 Run fstrim after moving a disk or migrating the VM.
16
17 `type`=`<isa | virtio>` ('default =' `virtio`);;
18
19 Select the agent type
20
21 `arch`: `<aarch64 | x86_64>` ::
22
23 Virtual processor architecture. Defaults to the host.
24
25 `args`: `<string>` ::
26
27 Arbitrary arguments passed to kvm, for example:
28 +
29 args: -no-reboot -no-hpet
30 +
31 NOTE: this option is for experts only.
32
33 `audio0`: `device=<ich9-intel-hda|intel-hda|AC97> [,driver=<spice|none>]` ::
34
35 Configure a audio device, useful in combination with QXL/Spice.
36
37 `device`=`<AC97 | ich9-intel-hda | intel-hda>` ;;
38
39 Configure an audio device.
40
41 `driver`=`<none | spice>` ('default =' `spice`);;
42
43 Driver backend for the audio device.
44
45 `autostart`: `<boolean>` ('default =' `0`)::
46
47 Automatic restart after crash (currently ignored).
48
49 `balloon`: `<integer> (0 - N)` ::
50
51 Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
52
53 `bios`: `<ovmf | seabios>` ('default =' `seabios`)::
54
55 Select BIOS implementation.
56
57 `boot`: `[[legacy=]<[acdn]{1,4}>] [,order=<device[;device...]>]` ::
58
59 Specify guest boot order. Use the 'order=' sub-property as usage with no key or 'legacy=' is deprecated.
60
61 `legacy`=`<[acdn]{1,4}>` ('default =' `cdn`);;
62
63 Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n). Deprecated, use 'order=' instead.
64
65 `order`=`<device[;device...]>` ;;
66
67 The guest will attempt to boot from devices in the order they appear here.
68 +
69 Disks, optical drives and passed-through storage USB devices will be directly
70 booted from, NICs will load PXE, and PCIe devices will either behave like disks
71 (e.g. NVMe) or load an option ROM (e.g. RAID controller, hardware NIC).
72 +
73 Note that only devices in this list will be marked as bootable and thus loaded
74 by the guest firmware (BIOS/UEFI). If you require multiple disks for booting
75 (e.g. software-raid), you need to specify all of them here.
76 +
77 Overrides the deprecated 'legacy=[acdn]*' value when given.
78
79 `bootdisk`: `(ide|sata|scsi|virtio)\d+` ::
80
81 Enable booting from specified disk. Deprecated: Use 'boot: order=foo;bar' instead.
82
83 `cdrom`: `<volume>` ::
84
85 This is an alias for option -ide2
86
87 `cicustom`: `[meta=<volume>] [,network=<volume>] [,user=<volume>] [,vendor=<volume>]` ::
88
89 cloud-init: Specify custom files to replace the automatically generated ones at start.
90
91 `meta`=`<volume>` ;;
92
93 Specify a custom file containing all meta data passed to the VM via"
94 ." cloud-init. This is provider specific meaning configdrive2 and nocloud differ.
95
96 `network`=`<volume>` ;;
97
98 Specify a custom file containing all network data passed to the VM via cloud-init.
99
100 `user`=`<volume>` ;;
101
102 Specify a custom file containing all user data passed to the VM via cloud-init.
103
104 `vendor`=`<volume>` ;;
105
106 Specify a custom file containing all vendor data passed to the VM via cloud-init.
107
108 `cipassword`: `<string>` ::
109
110 cloud-init: Password to assign the user. Using this is generally not recommended. Use ssh keys instead. Also note that older cloud-init versions do not support hashed passwords.
111
112 `citype`: `<configdrive2 | nocloud | opennebula>` ::
113
114 Specifies the cloud-init configuration format. The default depends on the configured operating system type (`ostype`. We use the `nocloud` format for Linux, and `configdrive2` for windows.
115
116 `ciuser`: `<string>` ::
117
118 cloud-init: User name to change ssh keys and password for instead of the image's configured default user.
119
120 `cores`: `<integer> (1 - N)` ('default =' `1`)::
121
122 The number of cores per socket.
123
124 `cpu`: `[[cputype=]<string>] [,flags=<+FLAG[;-FLAG...]>] [,hidden=<1|0>] [,hv-vendor-id=<vendor-id>] [,phys-bits=<8-64|host>] [,reported-model=<enum>]` ::
125
126 Emulated CPU type.
127
128 `cputype`=`<string>` ('default =' `kvm64`);;
129
130 Emulated CPU type. Can be default or custom name (custom model names must be prefixed with 'custom-').
131
132 `flags`=`<+FLAG[;-FLAG...]>` ;;
133
134 List of additional CPU flags separated by ';'. Use '+FLAG' to enable, '-FLAG' to disable a flag. Custom CPU models can specify any flag supported by QEMU/KVM, VM-specific flags must be from the following set for security reasons: pcid, spec-ctrl, ibpb, ssbd, virt-ssbd, amd-ssbd, amd-no-ssb, pdpe1gb, md-clear, hv-tlbflush, hv-evmcs, aes
135
136 `hidden`=`<boolean>` ('default =' `0`);;
137
138 Do not identify as a KVM virtual machine.
139
140 `hv-vendor-id`=`<vendor-id>` ;;
141
142 The Hyper-V vendor ID. Some drivers or programs inside Windows guests need a specific ID.
143
144 `phys-bits`=`<8-64|host>` ;;
145
146 The physical memory address bits that are reported to the guest OS. Should be smaller or equal to the host's. Set to 'host' to use value from host CPU, but note that doing so will break live migration to CPUs with other values.
147
148 `reported-model`=`<486 | Broadwell | Broadwell-IBRS | Broadwell-noTSX | Broadwell-noTSX-IBRS | Cascadelake-Server | Cascadelake-Server-noTSX | Conroe | EPYC | EPYC-IBPB | EPYC-Milan | EPYC-Rome | Haswell | Haswell-IBRS | Haswell-noTSX | Haswell-noTSX-IBRS | Icelake-Client | Icelake-Client-noTSX | Icelake-Server | Icelake-Server-noTSX | IvyBridge | IvyBridge-IBRS | KnightsMill | Nehalem | Nehalem-IBRS | Opteron_G1 | Opteron_G2 | Opteron_G3 | Opteron_G4 | Opteron_G5 | Penryn | SandyBridge | SandyBridge-IBRS | Skylake-Client | Skylake-Client-IBRS | Skylake-Client-noTSX-IBRS | Skylake-Server | Skylake-Server-IBRS | Skylake-Server-noTSX-IBRS | Westmere | Westmere-IBRS | athlon | core2duo | coreduo | host | kvm32 | kvm64 | max | pentium | pentium2 | pentium3 | phenom | qemu32 | qemu64>` ('default =' `kvm64`);;
149
150 CPU model and vendor to report to the guest. Must be a QEMU/KVM supported model. Only valid for custom CPU model definitions, default models will always report themselves to the guest OS.
151
152 `cpulimit`: `<number> (0 - 128)` ('default =' `0`)::
153
154 Limit of CPU usage.
155 +
156 NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.
157
158 `cpuunits`: `<integer> (1 - 262144)` ('default =' `cgroup v1: 1024, cgroup v2: 100`)::
159
160 CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.
161
162 `description`: `<string>` ::
163
164 Description for the VM. Shown in the web-interface VM's summary. This is saved as comment inside the configuration file.
165
166 `efidisk0`: `[file=]<volume> [,efitype=<2m|4m>] [,format=<enum>] [,pre-enrolled-keys=<1|0>] [,size=<DiskSize>]` ::
167
168 Configure a Disk for storing EFI vars.
169
170 `efitype`=`<2m | 4m>` ('default =' `2m`);;
171
172 Size and type of the OVMF EFI vars. '4m' is newer and recommended, and required for Secure Boot. For backwards compatibility, '2m' is used if not otherwise specified.
173
174 `file`=`<volume>` ;;
175
176 The drive's backing volume.
177
178 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
179
180 The drive's backing file's data format.
181
182 `pre-enrolled-keys`=`<boolean>` ('default =' `0`);;
183
184 Use am EFI vars template with distribution-specific and Microsoft Standard keys enrolled, if used with 'efitype=4m'. Note that this will enable Secure Boot by default, though it can still be turned off from within the VM.
185
186 `size`=`<DiskSize>` ;;
187
188 Disk size. This is purely informational and has no effect.
189
190 `freeze`: `<boolean>` ::
191
192 Freeze CPU at startup (use 'c' monitor command to start execution).
193
194 `hookscript`: `<string>` ::
195
196 Script that will be executed during various steps in the vms lifetime.
197
198 `hostpci[n]`: `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,device-id=<hex id>] [,legacy-igd=<1|0>] [,mdev=<string>] [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,sub-device-id=<hex id>] [,sub-vendor-id=<hex id>] [,vendor-id=<hex id>] [,x-vga=<1|0>]` ::
199
200 Map host PCI devices into guest.
201 +
202 NOTE: This option allows direct access to host hardware. So it is no longer
203 possible to migrate such machines - use with special care.
204 +
205 CAUTION: Experimental! User reported problems with this option.
206
207 `device-id`=`<hex id>` ;;
208
209 Override PCI device ID visible to guest
210
211 `host`=`<HOSTPCIID[;HOSTPCIID2...]>` ;;
212
213 Host PCI device pass through. The PCI ID of a host's PCI device or a list
214 of PCI virtual functions of the host. HOSTPCIID syntax is:
215 +
216 'bus:dev.func' (hexadecimal numbers)
217 +
218 You can us the 'lspci' command to list existing PCI devices.
219
220 `legacy-igd`=`<boolean>` ('default =' `0`);;
221
222 Pass this device in legacy IGD mode, making it the primary and exclusive graphics device in the VM. Requires 'pc-i440fx' machine type and VGA set to 'none'.
223
224 `mdev`=`<string>` ;;
225
226 The type of mediated device to use.
227 An instance of this type will be created on startup of the VM and
228 will be cleaned up when the VM stops.
229
230 `pcie`=`<boolean>` ('default =' `0`);;
231
232 Choose the PCI-express bus (needs the 'q35' machine model).
233
234 `rombar`=`<boolean>` ('default =' `1`);;
235
236 Specify whether or not the device's ROM will be visible in the guest's memory map.
237
238 `romfile`=`<string>` ;;
239
240 Custom pci device rom filename (must be located in /usr/share/kvm/).
241
242 `sub-device-id`=`<hex id>` ;;
243
244 Override PCI subsystem device ID visible to guest
245
246 `sub-vendor-id`=`<hex id>` ;;
247
248 Override PCI subsystem vendor ID visible to guest
249
250 `vendor-id`=`<hex id>` ;;
251
252 Override PCI vendor ID visible to guest
253
254 `x-vga`=`<boolean>` ('default =' `0`);;
255
256 Enable vfio-vga device support.
257
258 `hotplug`: `<string>` ('default =' `network,disk,usb`)::
259
260 Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Using '1' as value is an alias for the default `network,disk,usb`.
261
262 `hugepages`: `<1024 | 2 | any>` ::
263
264 Enable/disable hugepages memory.
265
266 `ide[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
267
268 Use volume as IDE hard disk or CD-ROM (n is 0 to 3).
269
270 `aio`=`<io_uring | native | threads>` ;;
271
272 AIO type to use.
273
274 `backup`=`<boolean>` ;;
275
276 Whether the drive should be included when making backups.
277
278 `bps`=`<bps>` ;;
279
280 Maximum r/w speed in bytes per second.
281
282 `bps_max_length`=`<seconds>` ;;
283
284 Maximum length of I/O bursts in seconds.
285
286 `bps_rd`=`<bps>` ;;
287
288 Maximum read speed in bytes per second.
289
290 `bps_rd_max_length`=`<seconds>` ;;
291
292 Maximum length of read I/O bursts in seconds.
293
294 `bps_wr`=`<bps>` ;;
295
296 Maximum write speed in bytes per second.
297
298 `bps_wr_max_length`=`<seconds>` ;;
299
300 Maximum length of write I/O bursts in seconds.
301
302 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
303
304 The drive's cache mode
305
306 `cyls`=`<integer>` ;;
307
308 Force the drive's physical geometry to have a specific cylinder count.
309
310 `detect_zeroes`=`<boolean>` ;;
311
312 Controls whether to detect and try to optimize writes of zeroes.
313
314 `discard`=`<ignore | on>` ;;
315
316 Controls whether to pass discard/trim requests to the underlying storage.
317
318 `file`=`<volume>` ;;
319
320 The drive's backing volume.
321
322 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
323
324 The drive's backing file's data format.
325
326 `heads`=`<integer>` ;;
327
328 Force the drive's physical geometry to have a specific head count.
329
330 `iops`=`<iops>` ;;
331
332 Maximum r/w I/O in operations per second.
333
334 `iops_max`=`<iops>` ;;
335
336 Maximum unthrottled r/w I/O pool in operations per second.
337
338 `iops_max_length`=`<seconds>` ;;
339
340 Maximum length of I/O bursts in seconds.
341
342 `iops_rd`=`<iops>` ;;
343
344 Maximum read I/O in operations per second.
345
346 `iops_rd_max`=`<iops>` ;;
347
348 Maximum unthrottled read I/O pool in operations per second.
349
350 `iops_rd_max_length`=`<seconds>` ;;
351
352 Maximum length of read I/O bursts in seconds.
353
354 `iops_wr`=`<iops>` ;;
355
356 Maximum write I/O in operations per second.
357
358 `iops_wr_max`=`<iops>` ;;
359
360 Maximum unthrottled write I/O pool in operations per second.
361
362 `iops_wr_max_length`=`<seconds>` ;;
363
364 Maximum length of write I/O bursts in seconds.
365
366 `mbps`=`<mbps>` ;;
367
368 Maximum r/w speed in megabytes per second.
369
370 `mbps_max`=`<mbps>` ;;
371
372 Maximum unthrottled r/w pool in megabytes per second.
373
374 `mbps_rd`=`<mbps>` ;;
375
376 Maximum read speed in megabytes per second.
377
378 `mbps_rd_max`=`<mbps>` ;;
379
380 Maximum unthrottled read pool in megabytes per second.
381
382 `mbps_wr`=`<mbps>` ;;
383
384 Maximum write speed in megabytes per second.
385
386 `mbps_wr_max`=`<mbps>` ;;
387
388 Maximum unthrottled write pool in megabytes per second.
389
390 `media`=`<cdrom | disk>` ('default =' `disk`);;
391
392 The drive's media type.
393
394 `model`=`<model>` ;;
395
396 The drive's reported model name, url-encoded, up to 40 bytes long.
397
398 `replicate`=`<boolean>` ('default =' `1`);;
399
400 Whether the drive should considered for replication jobs.
401
402 `rerror`=`<ignore | report | stop>` ;;
403
404 Read error action.
405
406 `secs`=`<integer>` ;;
407
408 Force the drive's physical geometry to have a specific sector count.
409
410 `serial`=`<serial>` ;;
411
412 The drive's reported serial number, url-encoded, up to 20 bytes long.
413
414 `shared`=`<boolean>` ('default =' `0`);;
415
416 Mark this locally-managed volume as available on all nodes.
417 +
418 WARNING: This option does not share the volume automatically, it assumes it is shared already!
419
420 `size`=`<DiskSize>` ;;
421
422 Disk size. This is purely informational and has no effect.
423
424 `snapshot`=`<boolean>` ;;
425
426 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
427
428 `ssd`=`<boolean>` ;;
429
430 Whether to expose this drive as an SSD, rather than a rotational hard disk.
431
432 `trans`=`<auto | lba | none>` ;;
433
434 Force disk geometry bios translation mode.
435
436 `werror`=`<enospc | ignore | report | stop>` ;;
437
438 Write error action.
439
440 `wwn`=`<wwn>` ;;
441
442 The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
443
444 `ipconfig[n]`: `[gw=<GatewayIPv4>] [,gw6=<GatewayIPv6>] [,ip=<IPv4Format/CIDR>] [,ip6=<IPv6Format/CIDR>]` ::
445
446 cloud-init: Specify IP addresses and gateways for the corresponding interface.
447 +
448 IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
449 +
450 The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit
451 gateway should be provided.
452 For IPv6 the special string 'auto' can be used to use stateless autoconfiguration. This requires
453 cloud-init 19.4 or newer.
454 +
455 If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using
456 dhcp on IPv4.
457
458 `gw`=`<GatewayIPv4>` ;;
459
460 Default gateway for IPv4 traffic.
461 +
462 NOTE: Requires option(s): `ip`
463
464 `gw6`=`<GatewayIPv6>` ;;
465
466 Default gateway for IPv6 traffic.
467 +
468 NOTE: Requires option(s): `ip6`
469
470 `ip`=`<IPv4Format/CIDR>` ('default =' `dhcp`);;
471
472 IPv4 address in CIDR format.
473
474 `ip6`=`<IPv6Format/CIDR>` ('default =' `dhcp`);;
475
476 IPv6 address in CIDR format.
477
478 `ivshmem`: `size=<integer> [,name=<string>]` ::
479
480 Inter-VM shared memory. Useful for direct communication between VMs, or to the host.
481
482 `name`=`<string>` ;;
483
484 The name of the file. Will be prefixed with 'pve-shm-'. Default is the VMID. Will be deleted when the VM is stopped.
485
486 `size`=`<integer> (1 - N)` ;;
487
488 The size of the file in MB.
489
490 `keephugepages`: `<boolean>` ('default =' `0`)::
491
492 Use together with hugepages. If enabled, hugepages will not not be deleted after VM shutdown and can be used for subsequent starts.
493
494 `keyboard`: `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ::
495
496 Keyboard layout for VNC server. This option is generally not required and is often better handled from within the guest OS.
497
498 `kvm`: `<boolean>` ('default =' `1`)::
499
500 Enable/disable KVM hardware virtualization.
501
502 `localtime`: `<boolean>` ::
503
504 Set the real time clock (RTC) to local time. This is enabled by default if the `ostype` indicates a Microsoft Windows OS.
505
506 `lock`: `<backup | clone | create | migrate | rollback | snapshot | snapshot-delete | suspended | suspending>` ::
507
508 Lock/unlock the VM.
509
510 `machine`: `(pc|pc(-i440fx)?-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|q35|pc-q35-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|virt(?:-\d+(\.\d+)+)?(\+pve\d+)?)` ::
511
512 Specifies the Qemu machine type.
513
514 `memory`: `<integer> (16 - N)` ('default =' `512`)::
515
516 Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
517
518 `migrate_downtime`: `<number> (0 - N)` ('default =' `0.1`)::
519
520 Set maximum tolerated downtime (in seconds) for migrations.
521
522 `migrate_speed`: `<integer> (0 - N)` ('default =' `0`)::
523
524 Set maximum speed (in MB/s) for migrations. Value 0 is no limit.
525
526 `name`: `<string>` ::
527
528 Set a name for the VM. Only used on the configuration web interface.
529
530 `nameserver`: `<string>` ::
531
532 cloud-init: Sets DNS server IP address for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
533
534 `net[n]`: `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,mtu=<integer>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
535
536 Specify network devices.
537
538 `bridge`=`<bridge>` ;;
539
540 Bridge to attach the network device to. The Proxmox VE standard bridge
541 is called 'vmbr0'.
542 +
543 If you do not specify a bridge, we create a kvm user (NATed) network
544 device, which provides DHCP and DNS services. The following addresses
545 are used:
546 +
547 10.0.2.2 Gateway
548 10.0.2.3 DNS Server
549 10.0.2.4 SMB Server
550 +
551 The DHCP server assign addresses to the guest starting from 10.0.2.15.
552
553 `firewall`=`<boolean>` ;;
554
555 Whether this interface should be protected by the firewall.
556
557 `link_down`=`<boolean>` ;;
558
559 Whether this interface should be disconnected (like pulling the plug).
560
561 `macaddr`=`<XX:XX:XX:XX:XX:XX>` ;;
562
563 A common MAC address with the I/G (Individual/Group) bit not set.
564
565 `model`=`<e1000 | e1000-82540em | e1000-82544gc | e1000-82545em | e1000e | i82551 | i82557b | i82559er | ne2k_isa | ne2k_pci | pcnet | rtl8139 | virtio | vmxnet3>` ;;
566
567 Network Card Model. The 'virtio' model provides the best performance with very low CPU overhead. If your guest does not support this driver, it is usually best to use 'e1000'.
568
569 `mtu`=`<integer> (1 - 65520)` ;;
570
571 Force MTU, for VirtIO only. Set to '1' to use the bridge MTU
572
573 `queues`=`<integer> (0 - 16)` ;;
574
575 Number of packet queues to be used on the device.
576
577 `rate`=`<number> (0 - N)` ;;
578
579 Rate limit in mbps (megabytes per second) as floating point number.
580
581 `tag`=`<integer> (1 - 4094)` ;;
582
583 VLAN tag to apply to packets on this interface.
584
585 `trunks`=`<vlanid[;vlanid...]>` ;;
586
587 VLAN trunks to pass through this interface.
588
589 `numa`: `<boolean>` ('default =' `0`)::
590
591 Enable/disable NUMA.
592
593 `numa[n]`: `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<number>] [,policy=<preferred|bind|interleave>]` ::
594
595 NUMA topology.
596
597 `cpus`=`<id[-id];...>` ;;
598
599 CPUs accessing this NUMA node.
600
601 `hostnodes`=`<id[-id];...>` ;;
602
603 Host NUMA nodes to use.
604
605 `memory`=`<number>` ;;
606
607 Amount of memory this NUMA node provides.
608
609 `policy`=`<bind | interleave | preferred>` ;;
610
611 NUMA allocation policy.
612
613 `onboot`: `<boolean>` ('default =' `0`)::
614
615 Specifies whether a VM will be started during system bootup.
616
617 `ostype`: `<l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win10 | win11 | win7 | win8 | wvista | wxp>` ::
618
619 Specify guest operating system. This is used to enable special
620 optimization/features for specific operating systems:
621 +
622 [horizontal]
623 other;; unspecified OS
624 wxp;; Microsoft Windows XP
625 w2k;; Microsoft Windows 2000
626 w2k3;; Microsoft Windows 2003
627 w2k8;; Microsoft Windows 2008
628 wvista;; Microsoft Windows Vista
629 win7;; Microsoft Windows 7
630 win8;; Microsoft Windows 8/2012/2012r2
631 win10;; Microsoft Windows 10/2016/2019
632 win11;; Microsoft Windows 11/2022
633 l24;; Linux 2.4 Kernel
634 l26;; Linux 2.6 - 5.X Kernel
635 solaris;; Solaris/OpenSolaris/OpenIndiania kernel
636
637 `parallel[n]`: `/dev/parport\d+|/dev/usb/lp\d+` ::
638
639 Map host parallel devices (n is 0 to 2).
640 +
641 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
642 machines - use with special care.
643 +
644 CAUTION: Experimental! User reported problems with this option.
645
646 `protection`: `<boolean>` ('default =' `0`)::
647
648 Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.
649
650 `reboot`: `<boolean>` ('default =' `1`)::
651
652 Allow reboot. If set to '0' the VM exit on reboot.
653
654 `rng0`: `[source=]</dev/urandom|/dev/random|/dev/hwrng> [,max_bytes=<integer>] [,period=<integer>]` ::
655
656 Configure a VirtIO-based Random Number Generator.
657
658 `max_bytes`=`<integer>` ('default =' `1024`);;
659
660 Maximum bytes of entropy allowed to get injected into the guest every 'period' milliseconds. Prefer a lower value when using '/dev/random' as source. Use `0` to disable limiting (potentially dangerous!).
661
662 `period`=`<integer>` ('default =' `1000`);;
663
664 Every 'period' milliseconds the entropy-injection quota is reset, allowing the guest to retrieve another 'max_bytes' of entropy.
665
666 `source`=`</dev/hwrng | /dev/random | /dev/urandom>` ;;
667
668 The file on the host to gather entropy from. In most cases '/dev/urandom' should be preferred over '/dev/random' to avoid entropy-starvation issues on the host. Using urandom does *not* decrease security in any meaningful way, as it's still seeded from real entropy, and the bytes provided will most likely be mixed with real entropy on the guest as well. '/dev/hwrng' can be used to pass through a hardware RNG from the host.
669
670 `sata[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
671
672 Use volume as SATA hard disk or CD-ROM (n is 0 to 5).
673
674 `aio`=`<io_uring | native | threads>` ;;
675
676 AIO type to use.
677
678 `backup`=`<boolean>` ;;
679
680 Whether the drive should be included when making backups.
681
682 `bps`=`<bps>` ;;
683
684 Maximum r/w speed in bytes per second.
685
686 `bps_max_length`=`<seconds>` ;;
687
688 Maximum length of I/O bursts in seconds.
689
690 `bps_rd`=`<bps>` ;;
691
692 Maximum read speed in bytes per second.
693
694 `bps_rd_max_length`=`<seconds>` ;;
695
696 Maximum length of read I/O bursts in seconds.
697
698 `bps_wr`=`<bps>` ;;
699
700 Maximum write speed in bytes per second.
701
702 `bps_wr_max_length`=`<seconds>` ;;
703
704 Maximum length of write I/O bursts in seconds.
705
706 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
707
708 The drive's cache mode
709
710 `cyls`=`<integer>` ;;
711
712 Force the drive's physical geometry to have a specific cylinder count.
713
714 `detect_zeroes`=`<boolean>` ;;
715
716 Controls whether to detect and try to optimize writes of zeroes.
717
718 `discard`=`<ignore | on>` ;;
719
720 Controls whether to pass discard/trim requests to the underlying storage.
721
722 `file`=`<volume>` ;;
723
724 The drive's backing volume.
725
726 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
727
728 The drive's backing file's data format.
729
730 `heads`=`<integer>` ;;
731
732 Force the drive's physical geometry to have a specific head count.
733
734 `iops`=`<iops>` ;;
735
736 Maximum r/w I/O in operations per second.
737
738 `iops_max`=`<iops>` ;;
739
740 Maximum unthrottled r/w I/O pool in operations per second.
741
742 `iops_max_length`=`<seconds>` ;;
743
744 Maximum length of I/O bursts in seconds.
745
746 `iops_rd`=`<iops>` ;;
747
748 Maximum read I/O in operations per second.
749
750 `iops_rd_max`=`<iops>` ;;
751
752 Maximum unthrottled read I/O pool in operations per second.
753
754 `iops_rd_max_length`=`<seconds>` ;;
755
756 Maximum length of read I/O bursts in seconds.
757
758 `iops_wr`=`<iops>` ;;
759
760 Maximum write I/O in operations per second.
761
762 `iops_wr_max`=`<iops>` ;;
763
764 Maximum unthrottled write I/O pool in operations per second.
765
766 `iops_wr_max_length`=`<seconds>` ;;
767
768 Maximum length of write I/O bursts in seconds.
769
770 `mbps`=`<mbps>` ;;
771
772 Maximum r/w speed in megabytes per second.
773
774 `mbps_max`=`<mbps>` ;;
775
776 Maximum unthrottled r/w pool in megabytes per second.
777
778 `mbps_rd`=`<mbps>` ;;
779
780 Maximum read speed in megabytes per second.
781
782 `mbps_rd_max`=`<mbps>` ;;
783
784 Maximum unthrottled read pool in megabytes per second.
785
786 `mbps_wr`=`<mbps>` ;;
787
788 Maximum write speed in megabytes per second.
789
790 `mbps_wr_max`=`<mbps>` ;;
791
792 Maximum unthrottled write pool in megabytes per second.
793
794 `media`=`<cdrom | disk>` ('default =' `disk`);;
795
796 The drive's media type.
797
798 `replicate`=`<boolean>` ('default =' `1`);;
799
800 Whether the drive should considered for replication jobs.
801
802 `rerror`=`<ignore | report | stop>` ;;
803
804 Read error action.
805
806 `secs`=`<integer>` ;;
807
808 Force the drive's physical geometry to have a specific sector count.
809
810 `serial`=`<serial>` ;;
811
812 The drive's reported serial number, url-encoded, up to 20 bytes long.
813
814 `shared`=`<boolean>` ('default =' `0`);;
815
816 Mark this locally-managed volume as available on all nodes.
817 +
818 WARNING: This option does not share the volume automatically, it assumes it is shared already!
819
820 `size`=`<DiskSize>` ;;
821
822 Disk size. This is purely informational and has no effect.
823
824 `snapshot`=`<boolean>` ;;
825
826 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
827
828 `ssd`=`<boolean>` ;;
829
830 Whether to expose this drive as an SSD, rather than a rotational hard disk.
831
832 `trans`=`<auto | lba | none>` ;;
833
834 Force disk geometry bios translation mode.
835
836 `werror`=`<enospc | ignore | report | stop>` ;;
837
838 Write error action.
839
840 `wwn`=`<wwn>` ;;
841
842 The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
843
844 `scsi[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,ro=<1|0>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
845
846 Use volume as SCSI hard disk or CD-ROM (n is 0 to 30).
847
848 `aio`=`<io_uring | native | threads>` ;;
849
850 AIO type to use.
851
852 `backup`=`<boolean>` ;;
853
854 Whether the drive should be included when making backups.
855
856 `bps`=`<bps>` ;;
857
858 Maximum r/w speed in bytes per second.
859
860 `bps_max_length`=`<seconds>` ;;
861
862 Maximum length of I/O bursts in seconds.
863
864 `bps_rd`=`<bps>` ;;
865
866 Maximum read speed in bytes per second.
867
868 `bps_rd_max_length`=`<seconds>` ;;
869
870 Maximum length of read I/O bursts in seconds.
871
872 `bps_wr`=`<bps>` ;;
873
874 Maximum write speed in bytes per second.
875
876 `bps_wr_max_length`=`<seconds>` ;;
877
878 Maximum length of write I/O bursts in seconds.
879
880 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
881
882 The drive's cache mode
883
884 `cyls`=`<integer>` ;;
885
886 Force the drive's physical geometry to have a specific cylinder count.
887
888 `detect_zeroes`=`<boolean>` ;;
889
890 Controls whether to detect and try to optimize writes of zeroes.
891
892 `discard`=`<ignore | on>` ;;
893
894 Controls whether to pass discard/trim requests to the underlying storage.
895
896 `file`=`<volume>` ;;
897
898 The drive's backing volume.
899
900 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
901
902 The drive's backing file's data format.
903
904 `heads`=`<integer>` ;;
905
906 Force the drive's physical geometry to have a specific head count.
907
908 `iops`=`<iops>` ;;
909
910 Maximum r/w I/O in operations per second.
911
912 `iops_max`=`<iops>` ;;
913
914 Maximum unthrottled r/w I/O pool in operations per second.
915
916 `iops_max_length`=`<seconds>` ;;
917
918 Maximum length of I/O bursts in seconds.
919
920 `iops_rd`=`<iops>` ;;
921
922 Maximum read I/O in operations per second.
923
924 `iops_rd_max`=`<iops>` ;;
925
926 Maximum unthrottled read I/O pool in operations per second.
927
928 `iops_rd_max_length`=`<seconds>` ;;
929
930 Maximum length of read I/O bursts in seconds.
931
932 `iops_wr`=`<iops>` ;;
933
934 Maximum write I/O in operations per second.
935
936 `iops_wr_max`=`<iops>` ;;
937
938 Maximum unthrottled write I/O pool in operations per second.
939
940 `iops_wr_max_length`=`<seconds>` ;;
941
942 Maximum length of write I/O bursts in seconds.
943
944 `iothread`=`<boolean>` ;;
945
946 Whether to use iothreads for this drive
947
948 `mbps`=`<mbps>` ;;
949
950 Maximum r/w speed in megabytes per second.
951
952 `mbps_max`=`<mbps>` ;;
953
954 Maximum unthrottled r/w pool in megabytes per second.
955
956 `mbps_rd`=`<mbps>` ;;
957
958 Maximum read speed in megabytes per second.
959
960 `mbps_rd_max`=`<mbps>` ;;
961
962 Maximum unthrottled read pool in megabytes per second.
963
964 `mbps_wr`=`<mbps>` ;;
965
966 Maximum write speed in megabytes per second.
967
968 `mbps_wr_max`=`<mbps>` ;;
969
970 Maximum unthrottled write pool in megabytes per second.
971
972 `media`=`<cdrom | disk>` ('default =' `disk`);;
973
974 The drive's media type.
975
976 `queues`=`<integer> (2 - N)` ;;
977
978 Number of queues.
979
980 `replicate`=`<boolean>` ('default =' `1`);;
981
982 Whether the drive should considered for replication jobs.
983
984 `rerror`=`<ignore | report | stop>` ;;
985
986 Read error action.
987
988 `ro`=`<boolean>` ;;
989
990 Whether the drive is read-only.
991
992 `scsiblock`=`<boolean>` ('default =' `0`);;
993
994 whether to use scsi-block for full passthrough of host block device
995 +
996 WARNING: can lead to I/O errors in combination with low memory or high memory fragmentation on host
997
998 `secs`=`<integer>` ;;
999
1000 Force the drive's physical geometry to have a specific sector count.
1001
1002 `serial`=`<serial>` ;;
1003
1004 The drive's reported serial number, url-encoded, up to 20 bytes long.
1005
1006 `shared`=`<boolean>` ('default =' `0`);;
1007
1008 Mark this locally-managed volume as available on all nodes.
1009 +
1010 WARNING: This option does not share the volume automatically, it assumes it is shared already!
1011
1012 `size`=`<DiskSize>` ;;
1013
1014 Disk size. This is purely informational and has no effect.
1015
1016 `snapshot`=`<boolean>` ;;
1017
1018 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
1019
1020 `ssd`=`<boolean>` ;;
1021
1022 Whether to expose this drive as an SSD, rather than a rotational hard disk.
1023
1024 `trans`=`<auto | lba | none>` ;;
1025
1026 Force disk geometry bios translation mode.
1027
1028 `werror`=`<enospc | ignore | report | stop>` ;;
1029
1030 Write error action.
1031
1032 `wwn`=`<wwn>` ;;
1033
1034 The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
1035
1036 `scsihw`: `<lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single>` ('default =' `lsi`)::
1037
1038 SCSI controller model
1039
1040 `searchdomain`: `<string>` ::
1041
1042 cloud-init: Sets DNS search domains for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
1043
1044 `serial[n]`: `(/dev/.+|socket)` ::
1045
1046 Create a serial device inside the VM (n is 0 to 3), and pass through a
1047 host serial device (i.e. /dev/ttyS0), or create a unix socket on the
1048 host side (use 'qm terminal' to open a terminal connection).
1049 +
1050 NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines -
1051 use with special care.
1052 +
1053 CAUTION: Experimental! User reported problems with this option.
1054
1055 `shares`: `<integer> (0 - 50000)` ('default =' `1000`)::
1056
1057 Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.
1058
1059 `smbios1`: `[base64=<1|0>] [,family=<Base64 encoded string>] [,manufacturer=<Base64 encoded string>] [,product=<Base64 encoded string>] [,serial=<Base64 encoded string>] [,sku=<Base64 encoded string>] [,uuid=<UUID>] [,version=<Base64 encoded string>]` ::
1060
1061 Specify SMBIOS type 1 fields.
1062
1063 `base64`=`<boolean>` ;;
1064
1065 Flag to indicate that the SMBIOS values are base64 encoded
1066
1067 `family`=`<Base64 encoded string>` ;;
1068
1069 Set SMBIOS1 family string.
1070
1071 `manufacturer`=`<Base64 encoded string>` ;;
1072
1073 Set SMBIOS1 manufacturer.
1074
1075 `product`=`<Base64 encoded string>` ;;
1076
1077 Set SMBIOS1 product ID.
1078
1079 `serial`=`<Base64 encoded string>` ;;
1080
1081 Set SMBIOS1 serial number.
1082
1083 `sku`=`<Base64 encoded string>` ;;
1084
1085 Set SMBIOS1 SKU string.
1086
1087 `uuid`=`<UUID>` ;;
1088
1089 Set SMBIOS1 UUID.
1090
1091 `version`=`<Base64 encoded string>` ;;
1092
1093 Set SMBIOS1 version.
1094
1095 `smp`: `<integer> (1 - N)` ('default =' `1`)::
1096
1097 The number of CPUs. Please use option -sockets instead.
1098
1099 `sockets`: `<integer> (1 - N)` ('default =' `1`)::
1100
1101 The number of CPU sockets.
1102
1103 `spice_enhancements`: `[foldersharing=<1|0>] [,videostreaming=<off|all|filter>]` ::
1104
1105 Configure additional enhancements for SPICE.
1106
1107 `foldersharing`=`<boolean>` ('default =' `0`);;
1108
1109 Enable folder sharing via SPICE. Needs Spice-WebDAV daemon installed in the VM.
1110
1111 `videostreaming`=`<all | filter | off>` ('default =' `off`);;
1112
1113 Enable video streaming. Uses compression for detected video streams.
1114
1115 `sshkeys`: `<string>` ::
1116
1117 cloud-init: Setup public SSH keys (one key per line, OpenSSH format).
1118
1119 `startdate`: `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` ('default =' `now`)::
1120
1121 Set the initial date of the real time clock. Valid format for date are:'now' or '2006-06-17T16:01:21' or '2006-06-17'.
1122
1123 `startup`: `[[order=]\d+] [,up=\d+] [,down=\d+] ` ::
1124
1125 Startup and shutdown behavior. Order is a non-negative number defining the general startup order. Shutdown in done with reverse ordering. Additionally you can set the 'up' or 'down' delay in seconds, which specifies a delay to wait before the next VM is started or stopped.
1126
1127 `tablet`: `<boolean>` ('default =' `1`)::
1128
1129 Enable/disable the USB tablet device. This device is usually needed to allow absolute mouse positioning with VNC. Else the mouse runs out of sync with normal VNC clients. If you're running lots of console-only guests on one host, you may consider disabling this to save some context switches. This is turned off by default if you use spice (`qm set <vmid> --vga qxl`).
1130
1131 `tags`: `<string>` ::
1132
1133 Tags of the VM. This is only meta information.
1134
1135 `tdf`: `<boolean>` ('default =' `0`)::
1136
1137 Enable/disable time drift fix.
1138
1139 `template`: `<boolean>` ('default =' `0`)::
1140
1141 Enable/disable Template.
1142
1143 `tpmstate0`: `[file=]<volume> [,size=<DiskSize>] [,version=<v1.2|v2.0>]` ::
1144
1145 Configure a Disk for storing TPM state. The format is fixed to 'raw'.
1146
1147 `file`=`<volume>` ;;
1148
1149 The drive's backing volume.
1150
1151 `size`=`<DiskSize>` ;;
1152
1153 Disk size. This is purely informational and has no effect.
1154
1155 `version`=`<v1.2 | v2.0>` ('default =' `v2.0`);;
1156
1157 The TPM interface version. v2.0 is newer and should be preferred. Note that this cannot be changed later on.
1158
1159 `unused[n]`: `[file=]<volume>` ::
1160
1161 Reference to unused volumes. This is used internally, and should not be modified manually.
1162
1163 `file`=`<volume>` ;;
1164
1165 The drive's backing volume.
1166
1167 `usb[n]`: `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
1168
1169 Configure an USB device (n is 0 to 4).
1170
1171 `host`=`<HOSTUSBDEVICE|spice>` ;;
1172
1173 The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
1174 +
1175 'bus-port(.port)*' (decimal numbers) or
1176 'vendor_id:product_id' (hexadeciaml numbers) or
1177 'spice'
1178 +
1179 You can use the 'lsusb -t' command to list existing usb devices.
1180 +
1181 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
1182 machines - use with special care.
1183 +
1184 The value 'spice' can be used to add a usb redirection devices for spice.
1185
1186 `usb3`=`<boolean>` ('default =' `0`);;
1187
1188 Specifies whether if given host option is a USB3 device or port.
1189
1190 `vcpus`: `<integer> (1 - N)` ('default =' `0`)::
1191
1192 Number of hotplugged vcpus.
1193
1194 `vga`: `[[type=]<enum>] [,memory=<integer>]` ::
1195
1196 Configure the VGA Hardware. If you want to use high resolution modes (>= 1280x1024x16) you may need to increase the vga memory option. Since QEMU 2.9 the default VGA display type is 'std' for all OS types besides some Windows versions (XP and older) which use 'cirrus'. The 'qxl' option enables the SPICE display server. For win* OS you can select how many independent displays you want, Linux guests can add displays them self.
1197 You can also run without any graphic card, using a serial device as terminal.
1198
1199 `memory`=`<integer> (4 - 512)` ;;
1200
1201 Sets the VGA memory (in MiB). Has no effect with serial display.
1202
1203 `type`=`<cirrus | none | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | virtio | virtio-gl | vmware>` ('default =' `std`);;
1204
1205 Select the VGA type.
1206
1207 `virtio[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,ro=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
1208
1209 Use volume as VIRTIO hard disk (n is 0 to 15).
1210
1211 `aio`=`<io_uring | native | threads>` ;;
1212
1213 AIO type to use.
1214
1215 `backup`=`<boolean>` ;;
1216
1217 Whether the drive should be included when making backups.
1218
1219 `bps`=`<bps>` ;;
1220
1221 Maximum r/w speed in bytes per second.
1222
1223 `bps_max_length`=`<seconds>` ;;
1224
1225 Maximum length of I/O bursts in seconds.
1226
1227 `bps_rd`=`<bps>` ;;
1228
1229 Maximum read speed in bytes per second.
1230
1231 `bps_rd_max_length`=`<seconds>` ;;
1232
1233 Maximum length of read I/O bursts in seconds.
1234
1235 `bps_wr`=`<bps>` ;;
1236
1237 Maximum write speed in bytes per second.
1238
1239 `bps_wr_max_length`=`<seconds>` ;;
1240
1241 Maximum length of write I/O bursts in seconds.
1242
1243 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
1244
1245 The drive's cache mode
1246
1247 `cyls`=`<integer>` ;;
1248
1249 Force the drive's physical geometry to have a specific cylinder count.
1250
1251 `detect_zeroes`=`<boolean>` ;;
1252
1253 Controls whether to detect and try to optimize writes of zeroes.
1254
1255 `discard`=`<ignore | on>` ;;
1256
1257 Controls whether to pass discard/trim requests to the underlying storage.
1258
1259 `file`=`<volume>` ;;
1260
1261 The drive's backing volume.
1262
1263 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
1264
1265 The drive's backing file's data format.
1266
1267 `heads`=`<integer>` ;;
1268
1269 Force the drive's physical geometry to have a specific head count.
1270
1271 `iops`=`<iops>` ;;
1272
1273 Maximum r/w I/O in operations per second.
1274
1275 `iops_max`=`<iops>` ;;
1276
1277 Maximum unthrottled r/w I/O pool in operations per second.
1278
1279 `iops_max_length`=`<seconds>` ;;
1280
1281 Maximum length of I/O bursts in seconds.
1282
1283 `iops_rd`=`<iops>` ;;
1284
1285 Maximum read I/O in operations per second.
1286
1287 `iops_rd_max`=`<iops>` ;;
1288
1289 Maximum unthrottled read I/O pool in operations per second.
1290
1291 `iops_rd_max_length`=`<seconds>` ;;
1292
1293 Maximum length of read I/O bursts in seconds.
1294
1295 `iops_wr`=`<iops>` ;;
1296
1297 Maximum write I/O in operations per second.
1298
1299 `iops_wr_max`=`<iops>` ;;
1300
1301 Maximum unthrottled write I/O pool in operations per second.
1302
1303 `iops_wr_max_length`=`<seconds>` ;;
1304
1305 Maximum length of write I/O bursts in seconds.
1306
1307 `iothread`=`<boolean>` ;;
1308
1309 Whether to use iothreads for this drive
1310
1311 `mbps`=`<mbps>` ;;
1312
1313 Maximum r/w speed in megabytes per second.
1314
1315 `mbps_max`=`<mbps>` ;;
1316
1317 Maximum unthrottled r/w pool in megabytes per second.
1318
1319 `mbps_rd`=`<mbps>` ;;
1320
1321 Maximum read speed in megabytes per second.
1322
1323 `mbps_rd_max`=`<mbps>` ;;
1324
1325 Maximum unthrottled read pool in megabytes per second.
1326
1327 `mbps_wr`=`<mbps>` ;;
1328
1329 Maximum write speed in megabytes per second.
1330
1331 `mbps_wr_max`=`<mbps>` ;;
1332
1333 Maximum unthrottled write pool in megabytes per second.
1334
1335 `media`=`<cdrom | disk>` ('default =' `disk`);;
1336
1337 The drive's media type.
1338
1339 `replicate`=`<boolean>` ('default =' `1`);;
1340
1341 Whether the drive should considered for replication jobs.
1342
1343 `rerror`=`<ignore | report | stop>` ;;
1344
1345 Read error action.
1346
1347 `ro`=`<boolean>` ;;
1348
1349 Whether the drive is read-only.
1350
1351 `secs`=`<integer>` ;;
1352
1353 Force the drive's physical geometry to have a specific sector count.
1354
1355 `serial`=`<serial>` ;;
1356
1357 The drive's reported serial number, url-encoded, up to 20 bytes long.
1358
1359 `shared`=`<boolean>` ('default =' `0`);;
1360
1361 Mark this locally-managed volume as available on all nodes.
1362 +
1363 WARNING: This option does not share the volume automatically, it assumes it is shared already!
1364
1365 `size`=`<DiskSize>` ;;
1366
1367 Disk size. This is purely informational and has no effect.
1368
1369 `snapshot`=`<boolean>` ;;
1370
1371 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
1372
1373 `trans`=`<auto | lba | none>` ;;
1374
1375 Force disk geometry bios translation mode.
1376
1377 `werror`=`<enospc | ignore | report | stop>` ;;
1378
1379 Write error action.
1380
1381 `vmgenid`: `<UUID>` ('default =' `1 (autogenerated)`)::
1382
1383 The VM generation ID (vmgenid) device exposes a 128-bit integer value identifier to the guest OS. This allows to notify the guest operating system when the virtual machine is executed with a different configuration (e.g. snapshot execution or creation from a template). The guest operating system notices the change, and is then able to react as appropriate by marking its copies of distributed databases as dirty, re-initializing its random number generator, etc.
1384 Note that auto-creation only works when done through API/CLI create or update methods, but not when manually editing the config file.
1385
1386 `vmstatestorage`: `<string>` ::
1387
1388 Default storage for VM state volumes/files.
1389
1390 `watchdog`: `[[model=]<i6300esb|ib700>] [,action=<enum>]` ::
1391
1392 Create a virtual hardware watchdog device. Once enabled (by a guest action), the watchdog must be periodically polled by an agent inside the guest or else the watchdog will reset the guest (or execute the respective action specified)
1393
1394 `action`=`<debug | none | pause | poweroff | reset | shutdown>` ;;
1395
1396 The action to perform if after activation the guest fails to poll the watchdog in time.
1397
1398 `model`=`<i6300esb | ib700>` ('default =' `i6300esb`);;