]> git.proxmox.com Git - pve-docs.git/blobdiff - pveceph.adoc
fix wiki-special link to "USB installation"
[pve-docs.git] / pveceph.adoc
index 20b5b63a38e9138d5245a20b458fadedaf012dd0..8dc85680ded076094afd9d7afb724f5ccd1761e7 100644 (file)
@@ -18,8 +18,8 @@ DESCRIPTION
 -----------
 endif::manvolnum[]
 ifndef::manvolnum[]
-Manage Ceph Services on Proxmox VE Nodes
-========================================
+Deploy Hyper-Converged Ceph Cluster
+===================================
 :pve-toplevel:
 endif::manvolnum[]
 
@@ -58,15 +58,15 @@ and VMs on the same node is possible.
 To simplify management, we provide 'pveceph' - a tool to install and
 manage {ceph} services on {pve} nodes.
 
-.Ceph consists of a couple of Daemons footnote:[Ceph intro http://docs.ceph.com/docs/luminous/start/intro/], for use as a RBD storage:
+.Ceph consists of a couple of Daemons footnote:[Ceph intro https://docs.ceph.com/docs/{ceph_codename}/start/intro/], for use as a RBD storage:
 - Ceph Monitor (ceph-mon)
 - Ceph Manager (ceph-mgr)
 - Ceph OSD (ceph-osd; Object Storage Daemon)
 
 TIP: We highly recommend to get familiar with Ceph's architecture
-footnote:[Ceph architecture http://docs.ceph.com/docs/luminous/architecture/]
+footnote:[Ceph architecture https://docs.ceph.com/docs/{ceph_codename}/architecture/]
 and vocabulary
-footnote:[Ceph glossary http://docs.ceph.com/docs/luminous/glossary].
+footnote:[Ceph glossary https://docs.ceph.com/docs/{ceph_codename}/glossary].
 
 
 Precondition
@@ -76,7 +76,7 @@ To build a hyper-converged Proxmox + Ceph Cluster there should be at least
 three (preferably) identical servers for the setup.
 
 Check also the recommendations from
-http://docs.ceph.com/docs/luminous/start/hardware-recommendations/[Ceph's website].
+https://docs.ceph.com/docs/{ceph_codename}/start/hardware-recommendations/[Ceph's website].
 
 .CPU
 Higher CPU core frequency reduce latency and should be preferred. As a simple
@@ -86,9 +86,16 @@ provide enough resources for stable and durable Ceph performance.
 .Memory
 Especially in a hyper-converged setup, the memory consumption needs to be
 carefully monitored. In addition to the intended workload from virtual machines
-and container, Ceph needs enough memory available to provide good and stable
-performance. As a rule of thumb, for roughly 1 TiB of data, 1 GiB of memory
-will be used by an OSD. OSD caching will use additional memory.
+and containers, Ceph needs enough memory available to provide excellent and
+stable performance.
+
+As a rule of thumb, for roughly **1 TiB of data, 1 GiB of memory** will be used
+by an OSD. Especially during recovery, rebalancing or backfilling.
+
+The daemon itself will use additional memory. The Bluestore backend of the
+daemon requires by default **3-5 GiB of memory** (adjustable). In contrast, the
+legacy Filestore backend uses the OS page cache and the memory consumption is
+generally related to PGs of an OSD daemon.
 
 .Network
 We recommend a network bandwidth of at least 10 GbE or more, which is used
@@ -101,7 +108,7 @@ services on the same network and may even break the {pve} cluster stack.
 
 Further, estimate your bandwidth needs. While one HDD might not saturate a 1 Gb
 link, multiple HDD OSDs per node can, and modern NVMe SSDs will even saturate
-10 Gbps of bandwidth quickly. Deploying a network capable of even more bandwith
+10 Gbps of bandwidth quickly. Deploying a network capable of even more bandwidth
 will ensure that it isn't your bottleneck and won't be anytime soon, 25, 40 or
 even 100 GBps are possible.
 
@@ -212,8 +219,8 @@ This sets up an `apt` package repository in
 `/etc/apt/sources.list.d/ceph.list` and installs the required software.
 
 
-Creating initial Ceph configuration
------------------------------------
+Create initial Ceph configuration
+---------------------------------
 
 [thumbnail="screenshot/gui-ceph-config.png"]
 
@@ -234,19 +241,23 @@ configuration file.
 
 
 [[pve_ceph_monitors]]
-Creating Ceph Monitors
-----------------------
-
-[thumbnail="screenshot/gui-ceph-monitor.png"]
-
+Ceph Monitor
+-----------
 The Ceph Monitor (MON)
-footnote:[Ceph Monitor http://docs.ceph.com/docs/luminous/start/intro/]
+footnote:[Ceph Monitor https://docs.ceph.com/docs/{ceph_codename}/start/intro/]
 maintains a master copy of the cluster map. For high availability you need to
 have at least 3 monitors. One monitor will already be installed if you
 used the installation wizard. You won't need more than 3 monitors as long
 as your cluster is small to midsize, only really large clusters will
 need more than that.
 
+
+[[pveceph_create_mon]]
+Create Monitors
+~~~~~~~~~~~~~~~
+
+[thumbnail="screenshot/gui-ceph-monitor.png"]
+
 On each node where you want to place a monitor (three monitors are recommended),
 create it by using the 'Ceph -> Monitor' tab in the GUI or run.
 
@@ -256,32 +267,77 @@ create it by using the 'Ceph -> Monitor' tab in the GUI or run.
 pveceph mon create
 ----
 
-This will also install the needed Ceph Manager ('ceph-mgr') by default. If you
-do not want to install a manager, specify the '-exclude-manager' option.
+[[pveceph_destroy_mon]]
+Destroy Monitors
+~~~~~~~~~~~~~~~~
+
+To remove a Ceph Monitor via the GUI first select a node in the tree view and
+go to the **Ceph -> Monitor** panel. Select the MON and click the **Destroy**
+button.
+
+To remove a Ceph Monitor via the CLI first connect to the node on which the MON
+is running. Then execute the following command:
+[source,bash]
+----
+pveceph mon destroy
+----
+
+NOTE: At least three Monitors are needed for quorum.
 
 
 [[pve_ceph_manager]]
-Creating Ceph Manager
-----------------------
+Ceph Manager
+------------
+The Manager daemon runs alongside the monitors. It provides an interface to
+monitor the cluster. Since the Ceph luminous release at least one ceph-mgr
+footnote:[Ceph Manager https://docs.ceph.com/docs/{ceph_codename}/mgr/] daemon is
+required.
+
+[[pveceph_create_mgr]]
+Create Manager
+~~~~~~~~~~~~~~
 
-The Manager daemon runs alongside the monitors, providing an interface for
-monitoring the cluster. Since the Ceph luminous release the
-ceph-mgr footnote:[Ceph Manager http://docs.ceph.com/docs/luminous/mgr/] daemon
-is required. During monitor installation the ceph manager will be installed as
-well.
+Multiple Managers can be installed, but at any time only one Manager is active.
+
+[source,bash]
+----
+pveceph mgr create
+----
 
 NOTE: It is recommended to install the Ceph Manager on the monitor nodes. For
 high availability install more then one manager.
 
+
+[[pveceph_destroy_mgr]]
+Destroy Manager
+~~~~~~~~~~~~~~~
+
+To remove a Ceph Manager via the GUI first select a node in the tree view and
+go to the **Ceph -> Monitor** panel. Select the Manager and click the
+**Destroy** button.
+
+To remove a Ceph Monitor via the CLI first connect to the node on which the
+Manager is running. Then execute the following command:
 [source,bash]
 ----
-pveceph mgr create
+pveceph mgr destroy
 ----
 
+NOTE: A Ceph cluster can function without a Manager, but certain functions like
+the cluster status or usage require a running Manager.
+
 
 [[pve_ceph_osds]]
-Creating Ceph OSDs
-------------------
+Ceph OSDs
+---------
+Ceph **O**bject **S**torage **D**aemons are storing objects for Ceph over the
+network. It is recommended to use one OSD per physical disk.
+
+NOTE: By default an object is 4 MiB in size.
+
+[[pve_ceph_osd_create]]
+Create OSDs
+~~~~~~~~~~~
 
 [thumbnail="screenshot/gui-ceph-osd-status.png"]
 
@@ -292,8 +348,8 @@ via GUI or via CLI as follows:
 pveceph osd create /dev/sd[X]
 ----
 
-TIP: We recommend a Ceph cluster size, starting with 12 OSDs, distributed evenly
-among your, at least three nodes (4 OSDs on each node).
+TIP: We recommend a Ceph cluster size, starting with 12 OSDs, distributed
+evenly among your, at least three nodes (4 OSDs on each node).
 
 If the disk was used before (eg. ZFS/RAID/OSD), to remove partition table, boot
 sector and any OSD leftover the following command should be sufficient.
@@ -305,12 +361,11 @@ ceph-volume lvm zap /dev/sd[X] --destroy
 
 WARNING: The above command will destroy data on the disk!
 
-Ceph Bluestore
-~~~~~~~~~~~~~~
+.Ceph Bluestore
 
 Starting with the Ceph Kraken release, a new Ceph OSD storage type was
 introduced, the so called Bluestore
-footnote:[Ceph Bluestore http://ceph.com/community/new-luminous-bluestore/].
+footnote:[Ceph Bluestore https://ceph.com/community/new-luminous-bluestore/].
 This is the default when creating OSDs since Ceph Luminous.
 
 [source,bash]
@@ -321,8 +376,8 @@ pveceph osd create /dev/sd[X]
 .Block.db and block.wal
 
 If you want to use a separate DB/WAL device for your OSDs, you can specify it
-through the '-db_dev' and '-wal_dev' options. The WAL is placed with the DB, if not
-specified separately.
+through the '-db_dev' and '-wal_dev' options. The WAL is placed with the DB, if
+not specified separately.
 
 [source,bash]
 ----
@@ -330,7 +385,7 @@ pveceph osd create /dev/sd[X] -db_dev /dev/sd[Y] -wal_dev /dev/sd[Z]
 ----
 
 You can directly choose the size for those with the '-db_size' and '-wal_size'
-paremeters respectively. If they are not given the following values (in order)
+parameters respectively. If they are not given the following values (in order)
 will be used:
 
 * bluestore_block_{db,wal}_size from ceph configuration...
@@ -345,8 +400,7 @@ internal journal or write-ahead log. It is recommended to use a fast SSD or
 NVRAM for better performance.
 
 
-Ceph Filestore
-~~~~~~~~~~~~~~
+.Ceph Filestore
 
 Before Ceph Luminous, Filestore was used as default storage type for Ceph OSDs.
 Starting with Ceph Nautilus, {pve} does not support creating such OSDs with
@@ -358,8 +412,9 @@ Starting with Ceph Nautilus, {pve} does not support creating such OSDs with
 ceph-volume lvm create --filestore --data /dev/sd[X] --journal /dev/sd[Y]
 ----
 
-Destroying Ceph OSDs
---------------------
+[[pve_ceph_osd_destroy]]
+Destroy OSDs
+~~~~~~~~~~~~
 
 To remove an OSD via the GUI first select a {PVE} node in the tree view and go
 to the **Ceph -> OSD** panel. Select the OSD to destroy. Next click the **OUT**
@@ -387,14 +442,17 @@ WARNING: The above command will destroy data on the disk!
 
 
 [[pve_ceph_pools]]
-Creating Ceph Pools
--------------------
-
-[thumbnail="screenshot/gui-ceph-pools.png"]
-
+Ceph Pools
+----------
 A pool is a logical group for storing objects. It holds **P**lacement
 **G**roups (`PG`, `pg_num`), a collection of objects.
 
+
+Create Pools
+~~~~~~~~~~~~
+
+[thumbnail="screenshot/gui-ceph-pools.png"]
+
 When no options are given, we set a default of **128 PGs**, a **size of 3
 replicas** and a **min_size of 2 replicas** for serving objects in a degraded
 state.
@@ -404,7 +462,7 @@ NOTE: The default number of PGs works for 2-5 disks. Ceph throws a
 
 It is advised to calculate the PG number depending on your setup, you can find
 the formula and the PG calculator footnote:[PG calculator
-http://ceph.com/pgcalc/] online. While PGs can be increased later on, they can
+https://ceph.com/pgcalc/] online. While PGs can be increased later on, they can
 never be decreased.
 
 
@@ -422,9 +480,27 @@ mark the checkbox "Add storages" in the GUI or use the command line option
 
 Further information on Ceph pool handling can be found in the Ceph pool
 operation footnote:[Ceph pool operation
-http://docs.ceph.com/docs/luminous/rados/operations/pools/]
+https://docs.ceph.com/docs/{ceph_codename}/rados/operations/pools/]
 manual.
 
+
+Destroy Pools
+~~~~~~~~~~~~~
+
+To destroy a pool via the GUI select a node in the tree view and go to the
+**Ceph -> Pools** panel. Select the pool to destroy and click the **Destroy**
+button. To confirm the destruction of the pool you need to enter the pool name.
+
+Run the following command to destroy a pool. Specify the '-remove_storages' to
+also remove the associated storage.
+[source,bash]
+----
+pveceph pool destroy <name>
+----
+
+NOTE: Deleting the data of a pool is a background task and can take some time.
+You will notice that the data usage in the cluster is decreasing.
+
 [[pve_ceph_device_classes]]
 Ceph CRUSH & device classes
 ---------------------------
@@ -437,7 +513,7 @@ advantage that no central index service is needed. CRUSH works with a map of
 OSDs, buckets (device locations) and rulesets (data replication) for pools.
 
 NOTE: Further information can be found in the Ceph documentation, under the
-section CRUSH map footnote:[CRUSH map http://docs.ceph.com/docs/luminous/rados/operations/crush-map/].
+section CRUSH map footnote:[CRUSH map https://docs.ceph.com/docs/{ceph_codename}/rados/operations/crush-map/].
 
 This map can be altered to reflect different replication hierarchies. The object
 replicas can be separated (eg. failure domains), while maintaining the desired
@@ -500,8 +576,8 @@ ceph osd pool set <pool-name> crush_rule <rule-name>
 ----
 
 TIP: If the pool already contains objects, all of these have to be moved
-accordingly. Depending on your setup this may introduce a big performance hit on
-your cluster. As an alternative, you can create a new pool and move disks
+accordingly. Depending on your setup this may introduce a big performance hit
+on your cluster. As an alternative, you can create a new pool and move disks
 separately.
 
 
@@ -583,11 +659,11 @@ Since Luminous (12.2.x) you can also have multiple active metadata servers
 running, but this is normally only useful for a high count on parallel clients,
 as else the `MDS` seldom is the bottleneck. If you want to set this up please
 refer to the ceph documentation. footnote:[Configuring multiple active MDS
-daemons http://docs.ceph.com/docs/luminous/cephfs/multimds/]
+daemons https://docs.ceph.com/docs/{ceph_codename}/cephfs/multimds/]
 
 [[pveceph_fs_create]]
-Create CephFS
-~~~~~~~~~~~~~~~
+Create CephFS
+~~~~~~~~~~~~~
 
 With {pve}'s CephFS integration into you can create a CephFS easily over the
 Web GUI, the CLI or an external API interface. Some prerequisites are required
@@ -615,7 +691,7 @@ This creates a CephFS named `'cephfs'' using a pool for its data named
 Check the xref:pve_ceph_pools[{pve} managed Ceph pool chapter] or visit the
 Ceph documentation for more information regarding a fitting placement group
 number (`pg_num`) for your setup footnote:[Ceph Placement Groups
-http://docs.ceph.com/docs/luminous/rados/operations/placement-groups/].
+https://docs.ceph.com/docs/{ceph_codename}/rados/operations/placement-groups/].
 Additionally, the `'--add-storage'' parameter will add the CephFS to the {pve}
 storage configuration after it was created successfully.
 
@@ -648,6 +724,67 @@ pveceph pool destroy NAME
 ----
 
 
+Ceph maintenance
+----------------
+
+Replace OSDs
+~~~~~~~~~~~~
+
+One of the common maintenance tasks in Ceph is to replace a disk of an OSD. If
+a disk is already in a failed state, then you can go ahead and run through the
+steps in xref:pve_ceph_osd_destroy[Destroy OSDs]. Ceph will recreate those
+copies on the remaining OSDs if possible. This rebalancing will start as soon
+as an OSD failure is detected or an OSD was actively stopped.
+
+NOTE: With the default size/min_size (3/2) of a pool, recovery only starts when
+`size + 1` nodes are available. The reason for this is that the Ceph object
+balancer xref:pve_ceph_device_classes[CRUSH] defaults to a full node as
+`failure domain'.
+
+To replace a still functioning disk, on the GUI go through the steps in
+xref:pve_ceph_osd_destroy[Destroy OSDs]. The only addition is to wait until
+the cluster shows 'HEALTH_OK' before stopping the OSD to destroy it.
+
+On the command line use the following commands.
+----
+ceph osd out osd.<id>
+----
+
+You can check with the command below if the OSD can be safely removed.
+----
+ceph osd safe-to-destroy osd.<id>
+----
+
+Once the above check tells you that it is save to remove the OSD, you can
+continue with following commands.
+----
+systemctl stop ceph-osd@<id>.service
+pveceph osd destroy <id>
+----
+
+Replace the old disk with the new one and use the same procedure as described
+in xref:pve_ceph_osd_create[Create OSDs].
+
+Trim/Discard
+~~~~~~~~~~~~
+It is a good measure to run 'fstrim' (discard) regularly on VMs or containers.
+This releases data blocks that the filesystem isn’t using anymore. It reduces
+data usage and resource load. Most modern operating systems issue such discard
+commands to their disks regularly. You only need to ensure that the Virtual
+Machines enable the xref:qm_hard_disk_discard[disk discard option].
+
+[[pveceph_scrub]]
+Scrub & Deep Scrub
+~~~~~~~~~~~~~~~~~~
+Ceph ensures data integrity by 'scrubbing' placement groups. Ceph checks every
+object in a PG for its health. There are two forms of Scrubbing, daily
+cheap metadata checks and weekly deep data checks. The weekly deep scrub reads
+the objects and uses checksums to ensure data integrity. If a running scrub
+interferes with business (performance) needs, you can adjust the time when
+scrubs footnote:[Ceph scrubbing https://docs.ceph.com/docs/{ceph_codename}/rados/configuration/osd-config-ref/#scrubbing]
+are executed.
+
+
 Ceph monitoring and troubleshooting
 -----------------------------------
 A good start is to continuosly monitor the ceph health from the start of
@@ -668,10 +805,10 @@ pve# ceph -w
 
 To get a more detailed view, every ceph service has a log file under
 `/var/log/ceph/` and if there is not enough detail, the log level can be
-adjusted footnote:[Ceph log and debugging http://docs.ceph.com/docs/luminous/rados/troubleshooting/log-and-debug/].
+adjusted footnote:[Ceph log and debugging https://docs.ceph.com/docs/{ceph_codename}/rados/troubleshooting/log-and-debug/].
 
 You can find more information about troubleshooting
-footnote:[Ceph troubleshooting http://docs.ceph.com/docs/luminous/rados/troubleshooting/]
+footnote:[Ceph troubleshooting https://docs.ceph.com/docs/{ceph_codename}/rados/troubleshooting/]
 a Ceph cluster on the official website.