]>
Commit | Line | Data |
---|---|---|
e3e34a10 TL |
1 | qemu-server (7.1-4) bullseye; urgency=medium |
2 | ||
3 | * migrate: send updated TPM state volume ID to target node on local-storage | |
4 | migration | |
5 | ||
6 | -- Proxmox Support Team <support@proxmox.com> Mon, 22 Nov 2021 17:07:13 +0100 | |
7 | ||
dce63c70 TL |
8 | qemu-server (7.1-3) bullseye; urgency=medium |
9 | ||
10 | * replication: do not setup NBD server on VM migrate for the TPM state, | |
11 | QEMU cannot access it directly and we already migrate it via the non-QEMU | |
12 | storage migration anyway. | |
13 | ||
14 | -- Proxmox Support Team <support@proxmox.com> Tue, 16 Nov 2021 14:04:45 +0100 | |
15 | ||
248fab7a | 16 | qemu-server (7.1-2) bullseye; urgency=medium |
701a86f2 TL |
17 | |
18 | * cfg2cmd: disable SMM when display=none and SeaBIOS is both used | |
19 | ||
20 | * pci: do not reserve pci-ids for mediated devices, already handled by sysfs | |
21 | anyway | |
22 | ||
248fab7a TL |
23 | * exclude efidisk and tpmstate for boot disk selection heuristic |
24 | ||
25 | -- Proxmox Support Team <support@proxmox.com> Mon, 15 Nov 2021 16:59:23 +0100 | |
701a86f2 | 26 | |
2db2ecc6 TL |
27 | qemu-server (7.0-19) bullseye; urgency=medium |
28 | ||
29 | * rollback: improve interaction with snapshot replication | |
30 | ||
31 | * cli: qm: rename 'move_disk' command to 'move-disk' with an alias for | |
32 | backward compatibility | |
33 | ||
34 | * pi: move-disk: add possibility to reassign a disk to another VM | |
35 | ||
36 | * turn SMM off when SeaBIOS and a serial-display are used in combination to | |
37 | avoid a possible boot loop | |
38 | ||
39 | -- Proxmox Support Team <support@proxmox.com> Thu, 11 Nov 2021 12:49:10 +0100 | |
40 | ||
b20f2670 TL |
41 | qemu-server (7.0-18) bullseye; urgency=medium |
42 | ||
43 | * use non SMM ovmf code file for i440fx machines | |
44 | ||
45 | * fix hot-unplugging (removing) a cpulimit on a running VM | |
46 | ||
47 | * vm start: only print tpm-related message if there is an actual instance | |
48 | ||
49 | * vzdump: increase timeout for QMP 'cont' command after backup started | |
50 | ||
51 | * drives: expose readonly flag for SCSI/VirtIO drives as 'ro' property | |
52 | ||
53 | * qemu-agent: allow hotplug of the 'fstrim cloned disk' option | |
54 | ||
55 | * fix #2429: allow to specify cloud-init vendor snippet via 'cicustom' | |
56 | ||
57 | * config: add new meta property with the VM creation time | |
58 | ||
59 | * config: meta: also save the QEMU version installed during creation | |
60 | ||
61 | * cfg2cmd: switch off ACPI hotplug on bridges for q35 VMs with linux as | |
62 | ostype to avoid changes in network interface naming due to systemd's | |
63 | predicatble naming scheme | |
64 | ||
65 | -- Proxmox Support Team <support@proxmox.com> Thu, 04 Nov 2021 15:29:55 +0100 | |
66 | ||
c21013ac TL |
67 | qemu-server (7.0-17) bullseye; urgency=medium |
68 | ||
69 | * fix #3258: block vm start when a PCI(e) device is already in use | |
70 | ||
71 | * snapshot: fix TPM state with RBD | |
72 | ||
73 | * swtpm: wait for PID file to appear before continuing with VM start | |
74 | ||
75 | * OS type: add entry for Windows 11/Server 2022 | |
76 | ||
77 | -- Proxmox Support Team <support@proxmox.com> Thu, 21 Oct 2021 11:57:09 +0200 | |
78 | ||
96a3f51f TL |
79 | qemu-server (7.0-16) bullseye; urgency=medium |
80 | ||
81 | * ovmf: support secure boot enabled code images | |
82 | ||
83 | * ovmf: support provisioning an EFI vars template with secureboot by default | |
84 | on and distribution + Microsofts secure-boot key pre-enrolled | |
85 | ||
86 | -- Proxmox Support Team <support@proxmox.com> Tue, 05 Oct 2021 20:22:18 +0200 | |
87 | ||
759dd88a TL |
88 | qemu-server (7.0-15) bullseye; urgency=medium |
89 | ||
90 | * api: return task-worker UPID in create template endpoint | |
91 | ||
92 | * api: destroy VM: remove pending volumes as well | |
93 | ||
94 | * fix #3075: add TPM v1.2 and v2.0 support via swtpm~ | |
95 | ||
96 | -- Proxmox Support Team <support@proxmox.com> Tue, 05 Oct 2021 07:24:52 +0200 | |
97 | ||
243af50d TL |
98 | qemu-server (7.0-14) bullseye; urgency=medium |
99 | ||
100 | * fix #3581: pass size via argument for memory-backend-ram QMP call | |
101 | ||
102 | * fix #3608: improve removal of the underlying SCSI controller when removing | |
103 | last drive on it | |
104 | ||
105 | * migrate: do not suggest that we map shared storages to avoid that | |
106 | subsequent checks could result in false negatives. | |
107 | ||
108 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Sep 2021 09:31:06 +0200 | |
109 | ||
0d519cfc FG |
110 | qemu-server (7.0-13) bullseye; urgency=medium |
111 | ||
112 | * fix bootorder regression with implicit default order | |
113 | ||
114 | -- Proxmox Support Team <support@proxmox.com> Thu, 5 Aug 2021 14:03:14 +0200 | |
115 | ||
94e30717 TL |
116 | qemu-server (7.0-12) bullseye; urgency=medium |
117 | ||
118 | * fix #3371: import ovf: allow the use of dots in the VM name | |
119 | ||
120 | * bootorder: fix double entry on cdrom edit | |
121 | ||
122 | -- Proxmox Support Team <support@proxmox.com> Fri, 30 Jul 2021 16:53:44 +0200 | |
123 | ||
619a4399 TL |
124 | qemu-server (7.0-11) bullseye; urgency=medium |
125 | ||
126 | * nic: support the intel e1000e model | |
127 | ||
128 | * lvm: avoid the use of io_uring for now | |
129 | ||
130 | * live-restore: fail early if target storage doesn't exist | |
131 | ||
132 | * api: always add new CD drives to bootorder | |
133 | ||
134 | * fix #2563: allow live migration with local cloud-init disk | |
135 | ||
136 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Jul 2021 11:08:48 +0200 | |
137 | ||
b236d33e TL |
138 | qemu-server (7.0-10) bullseye; urgency=medium |
139 | ||
140 | * avoid using io_uring for drives backed by LVM and configured for write-back | |
141 | or write-through cache | |
142 | ||
143 | -- Proxmox Support Team <support@proxmox.com> Wed, 07 Jul 2021 14:56:34 +0200 | |
144 | ||
d2428c77 | 145 | qemu-server (7.0-9) bullseye; urgency=medium |
60ac4233 | 146 | |
d2428c77 TL |
147 | * cpu weight: always clamp value to lower maximum for cgroup v2 and fix |
148 | defaults (v1 -> 1024, v2 -> 100) | |
60ac4233 TL |
149 | |
150 | * api: improve error handling when applying pending config changes | |
151 | ||
d2428c77 | 152 | -- Proxmox Support Team <support@proxmox.com> Wed, 07 Jul 2021 12:02:13 +0200 |
60ac4233 | 153 | |
1a947e67 TL |
154 | qemu-server (7.0-7) bullseye; urgency=medium |
155 | ||
156 | * improve #3329: ensure write-back is used over write-around for EFI disk, | |
157 | as OVMF profits a lot from cached writes due to its frequent | |
158 | read-modify-write operations | |
159 | ||
160 | -- Proxmox Support Team <support@proxmox.com> Mon, 05 Jul 2021 20:49:50 +0200 | |
161 | ||
e43b1910 TL |
162 | qemu-server (7.0-6) bullseye; urgency=medium |
163 | ||
164 | * live-restore: preload efidisk before starting VM | |
165 | ||
166 | * For now do not use io_uring for drives backed by Ceph RBD, with KRBD and | |
167 | write-back or write-through cache enabled, as in that case some polling/IO | |
168 | may hang in QEMU 6.0. | |
169 | ||
170 | -- Proxmox Support Team <support@proxmox.com> Fri, 02 Jul 2021 09:45:06 +0200 | |
171 | ||
6185586e TL |
172 | qemu-server (7.0-5) bullseye; urgency=medium |
173 | ||
174 | * don't default to O_DIRECT (cache=none) on btrfs without nocow | |
175 | ||
defa8e21 TL |
176 | * fix #2175: api: update VM: check old drive-config for permissions too to |
177 | ensure a valid transition when limited to CDROM changes. | |
178 | ||
179 | -- Proxmox Support Team <support@proxmox.com> Thu, 24 Jun 2021 18:58:19 +0200 | |
6185586e | 180 | |
07dfe539 TL |
181 | qemu-server (7.0-4) bullseye; urgency=medium |
182 | ||
183 | * enable io-uring support by default when running QEMU 6.0 or newer | |
184 | ||
185 | * VM start: always check if storages of volumes support correct content-type | |
186 | ||
187 | * use KillMode 'process' for systemd scope to cope with depreacation of | |
188 | KillMode=none | |
189 | ||
190 | * cli, api: handle new warnings task status | |
191 | ||
192 | * improve backup of templates with EFI disks and with SATA and IDE | |
193 | disk controllers in use | |
194 | ||
195 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 Jun 2021 12:57:27 +0200 | |
196 | ||
a83b2330 TL |
197 | qemu-server (7.0-3) bullseye; urgency=medium |
198 | ||
199 | * vzdump: add master key support | |
200 | ||
201 | * vzdump: drop legacy fallback logging for dirty-bitmap | |
202 | ||
203 | * vm destroy: do not remove unreferenced disks by default | |
204 | ||
205 | * fix #3329: turn on cache=writeback for efidisks on rbd | |
206 | ||
207 | * avoid setting LUN number for drives when the `pvscsi` controller is used, | |
208 | as that cannot handle multiple LUNs, increase the `scsi-id` instead | |
209 | ||
210 | * config: limit description/comment length to 8 KiB | |
211 | ||
212 | * migrate: enforce that image content type is available and configured on | |
213 | target storage | |
214 | ||
215 | -- Proxmox Support Team <support@proxmox.com> Mon, 21 Jun 2021 11:17:52 +0200 | |
216 | ||
30aa4580 TL |
217 | qemu-server (7.0-2) bullseye; urgency=medium |
218 | ||
219 | * api: clone: sort vm disks to keep numbers consistent | |
220 | ||
221 | * api: VM status: make template property optional in return object | |
222 | ||
223 | * add compatibility for QEMU 6.0 | |
224 | ||
225 | * destroy VM: always remove (referenced) VM state volumes | |
226 | ||
227 | * destroy VM: also check if unused volumes are base images | |
228 | ||
229 | * live-restore: log more similar to regular restore, outputting the user the | |
230 | PBS repo/snapshot and target for each drive. | |
231 | ||
232 | -- Proxmox Support Team <support@proxmox.com> Fri, 28 May 2021 12:46:36 +0200 | |
233 | ||
c09667bc TL |
234 | qemu-server (7.0-1) pve; urgency=medium |
235 | ||
236 | * re-build for Proxmox VE 7 / Debian Bullseye | |
237 | ||
238 | -- Proxmox Support Team <support@proxmox.com> Thu, 13 May 2021 19:11:18 +0200 | |
239 | ||
c948e143 TL |
240 | qemu-server (6.4-2) pve; urgency=medium |
241 | ||
242 | * fix #2862: allow sata/ide template backups | |
243 | ||
244 | * migration: improve speed-limits for >1G connections again | |
245 | ||
246 | * fix getting bootdisk size for new bootorder config scheme | |
247 | ||
248 | -- Proxmox Support Team <support@proxmox.com> Thu, 29 Apr 2021 16:16:04 +0200 | |
249 | ||
ba2a06fd TL |
250 | qemu-server (6.4-1) pve; urgency=medium |
251 | ||
252 | * fix the +pveN versioned machine types when PXE is used | |
253 | ||
254 | * migration: avoid re-scanning all volumes | |
255 | ||
256 | * migration: do not always set default speed limit if none is configured | |
257 | ||
258 | * migration: rework logging to more humand friendly format, avoiding to much | |
259 | output noise | |
260 | ||
261 | * qmrestore: add live-restore option for CLI tool | |
262 | ||
263 | * live-restore: hold 'create' lock during operation | |
264 | ||
265 | * live-restore: don't remove VM on error, to allow an VM user to save any new | |
266 | data before retrying the operation. | |
267 | ||
268 | * fix #3369: auto-start vm after failed stopmode backup | |
269 | ||
270 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Apr 2021 16:26:54 +0200 | |
271 | ||
04fac98a TL |
272 | qemu-server (6.3-11) pve; urgency=medium |
273 | ||
274 | * enable live-restore tech preview for Proxmox Backup Server hosted backup | |
275 | snapshots. | |
276 | ||
277 | * drive mirror: rework periodic status reporting to be human friendlier | |
278 | ||
279 | * drive mirror: stop logging progress for a disk once it got ready | |
280 | ||
281 | * image convert: use human-readable units in progress report | |
282 | ||
283 | -- Proxmox Support Team <support@proxmox.com> Thu, 15 Apr 2021 18:32:06 +0200 | |
284 | ||
43bf6fc9 TL |
285 | qemu-server (6.3-10) pve; urgency=medium |
286 | ||
287 | * increase timeout for block (disk) resize QMP command | |
288 | ||
289 | * fix #3314: cloudinit: IPv6 requires type 'static6' | |
290 | ||
291 | * fix #2670: cloudinit: enable SLAAC again now that client support is there | |
292 | ||
293 | -- Proxmox Support Team <support@proxmox.com> Tue, 30 Mar 2021 18:40:58 +0200 | |
294 | ||
6fb28876 TL |
295 | qemu-server (6.3-9) pve; urgency=medium |
296 | ||
297 | * restore vma: fix applying storage-specific bandwidth limit | |
298 | ||
299 | * snapshot: set migration caps before savevm-start | |
300 | ||
301 | * vzdump: improve error logging for query-proxmox-support to avoid | |
302 | false-positives | |
303 | ||
304 | -- Proxmox Support Team <support@proxmox.com> Fri, 26 Mar 2021 09:47:27 +0100 | |
305 | ||
8e6bcc50 TL |
306 | qemu-server (6.3-8) pve; urgency=medium |
307 | ||
308 | * qm status: sort hash keys on verbose output | |
309 | ||
310 | * improve windows VM version pinning on VM creation | |
311 | ||
312 | -- Proxmox Support Team <support@proxmox.com> Fri, 12 Mar 2021 10:01:09 +0100 | |
313 | ||
31c8e14b TL |
314 | qemu-server (6.3-7) pve; urgency=medium |
315 | ||
316 | * vzdump: increase Proxmox Backup Server backup QMP command timeout | |
317 | ||
318 | -- Proxmox Support Team <support@proxmox.com> Tue, 09 Mar 2021 08:21:43 +0100 | |
319 | ||
533cde8f TL |
320 | qemu-server (6.3-6) pve; urgency=medium |
321 | ||
322 | * fix #3324: clone disk: use larger blocksize for EFI disk | |
323 | ||
324 | * fix #3301: status: add currently running machine and QEMU version to full | |
325 | status | |
326 | ||
327 | * api: add endpoint to list all available QEMU machine type and version | |
328 | tuples | |
329 | ||
330 | * always pin virtual machines with Windows as ostype to a fixed QEMU machine | |
331 | version by default. For existing VMs with Windows based OS-type use the 5.1 | |
332 | machine version (or the next available one, for older QEMU versions) to | |
333 | improve stabillity of the hardware layout from Windows point of view. Linux | |
334 | and other OS types are not as sensitive to those changes, so keep the | |
335 | default to the currently latest available machine versions for non-Windows | |
336 | VMs. | |
337 | ||
338 | * update VM: check for CDROM not just drive permissions when removing a | |
339 | device | |
340 | ||
341 | -- Proxmox Support Team <support@proxmox.com> Fri, 05 Mar 2021 21:42:59 +0100 | |
342 | ||
c1cac4c9 TL |
343 | qemu-server (6.3-5) pve; urgency=medium |
344 | ||
345 | * cloudinit: add opennebula config format | |
346 | ||
347 | * cloudinit: remove pending delete on online regenerate image | |
348 | ||
349 | * snapshot/save-vm: periodically print progress and show information about | |
350 | drives during snapshot | |
351 | ||
352 | * qmeventd: explicitly close() pidfds | |
353 | ||
354 | -- Proxmox Support Team <support@proxmox.com> Thu, 11 Feb 2021 18:05:18 +0100 | |
355 | ||
4603e15b TL |
356 | qemu-server (6.3-4) pve; urgency=medium |
357 | ||
358 | * audio: add the "none" dummy audio backend | |
359 | ||
360 | * fix drive-mirror completion with cloudinit | |
361 | ||
362 | * vm destroy: allow opt-out of purging unreferenced disks | |
363 | ||
364 | * fix #2788: do not resume vms after backup if they were paused before | |
365 | ||
366 | * anchor CPU flag regex to avoid arbitrary flag suffixes | |
367 | ||
368 | -- Proxmox Support Team <support@proxmox.com> Thu, 28 Jan 2021 17:21:07 +0100 | |
369 | ||
16782e5f TL |
370 | qemu-server (6.3-3) pve; urgency=medium |
371 | ||
372 | * api: adapt VM destroy and purge description | |
373 | ||
374 | * clone disk: fix regression in offline clone of efidisk | |
375 | ||
376 | * cloudinit: fix cloning/restoring of cloudinit disks in raw format | |
377 | ||
378 | -- Proxmox Support Team <support@proxmox.com> Tue, 15 Dec 2020 16:33:01 +0100 | |
379 | ||
6711e689 TL |
380 | qemu-server (6.3-2) pve; urgency=medium |
381 | ||
382 | * PBS: use improved method to assemble repository url, fixing issues when | |
383 | using IPv6 or non-default ports | |
384 | ||
385 | -- Proxmox Support Team <support@proxmox.com> Thu, 03 Dec 2020 18:06:25 +0100 | |
386 | ||
012b520e TL |
387 | qemu-server (6.3-1) pve; urgency=medium |
388 | ||
389 | * deactivate volumes after storage migrate | |
390 | ||
391 | * print query-proxmox-support result in 'full' status | |
392 | ||
393 | * clone disk: avoid errors after disk was moved by QEMU | |
394 | ||
395 | * replace cgroups_write by cgroup change_cpu_shares && change_cpu_quota | |
396 | ||
397 | -- Proxmox Support Team <support@proxmox.com> Wed, 25 Nov 2020 14:30:50 +0100 | |
398 | ||
ff072151 TL |
399 | qemu-server (6.2-20) pve; urgency=medium |
400 | ||
401 | * don't migrate replicated VM whose replication job is marked for | |
402 | removal | |
403 | ||
404 | * ensure qmeventd service is stopped after pve-guests and pve-ha-lrm service | |
405 | on shutdown | |
406 | ||
407 | -- Proxmox Support Team <support@proxmox.com> Thu, 12 Nov 2020 17:08:45 +0100 | |
408 | ||
1749a376 TL |
409 | qemu-server (6.2-19) pve; urgency=medium |
410 | ||
411 | * fix #3113: unbreak drive hotplug | |
412 | ||
413 | * qmeventd: add handling for -no-shutdown QEMU instances, to avoid errors if | |
414 | the guest OS shuts down the VM during a backup job. | |
415 | ||
416 | -- Proxmox Support Team <support@proxmox.com> Thu, 05 Nov 2020 13:37:00 +0100 | |
417 | ||
8c9021cd TL |
418 | qemu-server (6.2-18) pve; urgency=medium |
419 | ||
420 | * migrate: tell QEMU to enable dirty-bitmap migration, if supported | |
421 | ||
422 | * partially fix #3056: always try to cancel backups when failed to start job | |
423 | ||
424 | -- Proxmox Support Team <support@proxmox.com> Thu, 29 Oct 2020 18:23:13 +0100 | |
425 | ||
31655cbb TL |
426 | qemu-server (6.2-17) pve; urgency=medium |
427 | ||
428 | * bootorder: don't print empty 'order=' property | |
429 | ||
430 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Oct 2020 16:08:57 +0200 | |
431 | ||
75127d19 TL |
432 | qemu-server (6.2-16) pve; urgency=medium |
433 | ||
434 | * fix #3010: add 'bootorder' parameter for better control of boot devices | |
435 | ||
436 | * fix VM clone from snapshot with cloudinit disk | |
437 | ||
438 | * fix various possible issues by avoiding conditionally declared variables | |
439 | altogether | |
440 | ||
441 | * PCI passthrough: fix setting VGA to 'none' when marking passed-through | |
442 | device as 'Primary GPU' | |
443 | ||
444 | -- Proxmox Support Team <support@proxmox.com> Mon, 19 Oct 2020 15:51:48 +0200 | |
445 | ||
dbcc2dbb TL |
446 | qemu-server (6.2-15) pve; urgency=medium |
447 | ||
448 | * fix #2570: add 'keephugepages' config property | |
449 | ||
450 | * vzdump: log 'finishing' state for Proxmox Backup Server jobs, to avoid | |
451 | suggesting that the backup is stuck at 100%. This can happen when the | |
452 | validation and mark of pre-existing chunks needs a bit longer. | |
453 | ||
454 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Sep 2020 17:44:28 +0200 | |
455 | ||
116df99c TL |
456 | qemu-server (6.2-14) pve; urgency=medium |
457 | ||
458 | * vzdump: allow bandwidth limit also PBS backup | |
459 | ||
460 | * avoid a warning when checking the VMs bios | |
461 | ||
462 | * fix #2862: properly backup (all) VM templates | |
463 | ||
464 | -- Proxmox Support Team <support@proxmox.com> Mon, 24 Aug 2020 19:33:54 +0200 | |
465 | ||
75f25f44 | 466 | qemu-server (6.2-13) pve; urgency=medium |
db3272d0 TL |
467 | |
468 | * fix use of bandwidth limits with offline storage migrate | |
469 | ||
470 | * allow one to add CPU features with a dot, like "+sse4.2", correctly | |
471 | ||
75f25f44 | 472 | * vzdump: improve logging output and report dirty bitmap state for each disk |
db3272d0 TL |
473 | |
474 | * vzdump: display actually uploaded chunks as 'write' speed to conform more | |
475 | closely with the actual network transmission line-speed. | |
476 | ||
477 | * fix #2749: vga: disable the display EDID information for the combination of | |
478 | Windows SeaBIOS and VGA guests to avoid a reduced list of possible screen | |
479 | resolutions. (Windows may cache the list of possible resolutions, | |
480 | uninstalling 'Microsoft Basic Display Adapter' and rebooting may then help) | |
481 | ||
75f25f44 | 482 | -- Proxmox Support Team <support@proxmox.com> Thu, 20 Aug 2020 11:42:47 +0200 |
db3272d0 | 483 | |
bd9ab366 FG |
484 | qemu-server (6.2-11) pve; urgency=medium |
485 | ||
486 | * fix #2857: restore: pass keyfile to pbs-restore | |
487 | ||
488 | * fix #2728: die/warn if target is not a replication target when | |
489 | live-migrating | |
490 | ||
491 | -- Proxmox Support Team <support@proxmox.com> Fri, 24 Jul 2020 08:13:29 +0200 | |
492 | ||
6b84c2d6 TL |
493 | qemu-server (6.2-10) pve; urgency=medium |
494 | ||
495 | * pass-through: fix mdev cmdline generation | |
496 | ||
497 | * docs: add man page cpu-models.conf(5) | |
498 | ||
499 | * start: set resume parameter for VM start anytime there is a 'vmstate' in | |
500 | the config, not just when it has the 'suspend' lock | |
501 | ||
502 | -- Proxmox Support Team <support@proxmox.com> Mon, 13 Jul 2020 13:37:37 +0200 | |
503 | ||
70d3ff79 WB |
504 | qemu-server (6.2-9) pve; urgency=medium |
505 | ||
506 | * support encrypted pbs backups | |
507 | ||
508 | -- Proxmox Support Team <support@proxmox.com> Fri, 10 Jul 2020 14:23:46 +0200 | |
509 | ||
1e75990c | 510 | qemu-server (6.2-8) pve; urgency=medium |
b54ba7a1 TL |
511 | |
512 | * backup: detect PBS features and use only supported | |
513 | ||
514 | * fix #2671: include CPU format in man page again | |
515 | ||
1e75990c | 516 | -- Proxmox Support Team <support@proxmox.com> Thu, 09 Jul 2020 15:14:36 +0200 |
b54ba7a1 | 517 | |
fd98147d TL |
518 | qemu-server (6.2-6) pve; urgency=medium |
519 | ||
520 | * vzdump: fix variable redeclaration warning | |
277cdcb0 TL |
521 | |
522 | * make backup log more friendlier to read for humans | |
523 | ||
fd98147d | 524 | -- Proxmox Support Team <support@proxmox.com> Tue, 07 Jul 2020 19:00:09 +0200 |
277cdcb0 | 525 | |
c8239a84 TL |
526 | qemu-server (6.2-4) pve; urgency=medium |
527 | ||
528 | * fix #2787: properly parse vga for vncproxy | |
529 | ||
530 | * vncproxy: allow to request a generated VNC password | |
531 | ||
532 | * fix #2794: allow legacy IGD passthrough | |
533 | ||
534 | * avoid backup command timeout with PBS | |
535 | ||
536 | * fix #2741: add VM.Config.Cloudinit permission | |
537 | ||
538 | * enable dirty-bitmap incremental backups for PBS | |
539 | ||
540 | -- Proxmox Support Team <support@proxmox.com> Tue, 30 Jun 2020 11:33:35 +0200 | |
541 | ||
456071e5 TL |
542 | qemu-server (6.2-3) pve; urgency=medium |
543 | ||
544 | * fix #2748: make order of cloudinit interfaces consistent | |
545 | ||
546 | * fix #2774: add early check for non-managed volumes | |
547 | ||
548 | * allow to force MTU for a VM net-device | |
549 | ||
550 | -- Proxmox Support Team <support@proxmox.com> Thu, 04 Jun 2020 11:17:09 +0200 | |
551 | ||
81c44b9b TL |
552 | qemu-server (6.2-2) pve; urgency=medium |
553 | ||
554 | * adapt net-device hotplug to more strict QMP schema of QEMU 5.0 | |
555 | ||
556 | -- Proxmox Support Team <support@proxmox.com> Fri, 08 May 2020 13:00:18 +0200 | |
557 | ||
ba76fc63 TL |
558 | qemu-server (6.2-1) pve; urgency=medium |
559 | ||
560 | * qmrestore: fix VMA restore from STDIN | |
561 | ||
562 | -- Proxmox Support Team <support@proxmox.com> Thu, 07 May 2020 21:51:01 +0200 | |
563 | ||
19abcdd0 TL |
564 | qemu-server (6.1-20) pve; urgency=medium |
565 | ||
566 | * cfg2cmd: fix uninitialized value warning on OVMF w/o efidisk | |
567 | ||
568 | * vzdump: fix backup of templates with stdout as output | |
569 | ||
570 | * cfg2cmd: set audiodev parameter only on qemu >= 4.2 | |
571 | ||
572 | * api: allow listing custom and default CPU models | |
573 | ||
574 | -- Proxmox Support Team <support@proxmox.com> Wed, 06 May 2020 17:16:56 +0200 | |
575 | ||
7c54973e FG |
576 | qemu-server (6.1-19) pve; urgency=medium |
577 | ||
578 | * clone: use new config_lock_shared | |
579 | ||
580 | -- Proxmox Support Team <support@proxmox.com> Tue, 5 May 2020 11:22:04 +0200 | |
581 | ||
5a5ba294 TL |
582 | qemu-server (6.1-18) pve; urgency=medium |
583 | ||
584 | * vzdump: assemble: fix skipping all pending and snapshot config entries | |
585 | ||
586 | * api/destroy: repeat early checks after locking | |
587 | ||
588 | * migrate: skip rescan for efidisk and shared volumes | |
589 | ||
590 | -- Proxmox Support Team <support@proxmox.com> Mon, 04 May 2020 17:36:40 +0200 | |
591 | ||
fa38a812 FG |
592 | qemu-server (6.1-17) pve; urgency=medium |
593 | ||
594 | * backup: never try to freeze in stop mode backup | |
595 | ||
596 | * Fix #2124: Add support for zstd | |
597 | ||
598 | -- Proxmox Support Team <support@proxmox.com> Mon, 4 May 2020 14:11:50 +0200 | |
599 | ||
0433e98f | 600 | qemu-server (6.1-16) pve; urgency=medium |
0091afc7 TL |
601 | |
602 | * spice audio: improve compatibility with QEMU versions newer than 4.2 | |
603 | ||
604 | * migrate: workaround issues with format switch on storage live migration | |
605 | ||
606 | * fix live migration with replicated unused volumes | |
607 | ||
608 | * importovf: improve compatibility with OVF files without default namespaces | |
609 | ||
610 | * backup restore: use correct storage for format check for cloudinit drives | |
611 | ||
0433e98f TL |
612 | * handle stopping the storage migration NBD server better |
613 | ||
614 | -- Proxmox Support Team <support@proxmox.com> Wed, 29 Apr 2020 16:23:24 +0200 | |
0091afc7 | 615 | |
89b0461a FG |
616 | qemu-server (6.1-14) pve; urgency=medium |
617 | ||
618 | * Use foreach_volume instead of foreach_drive | |
619 | ||
620 | * Use new storage_migrate interface | |
621 | ||
622 | * migrate: update config with changed volume IDs | |
623 | ||
624 | * migrate: allow specifying targetstorage for offline migration | |
625 | ||
626 | * migrate: sync_disks: use allow_rename to avoid collisions on the target | |
627 | storage | |
628 | ||
629 | * migrate: sync_disks: log output of storage_migrate | |
630 | ||
631 | * migrate: also cleanup disks migrated by storage_migrate in case of failure | |
632 | ||
633 | -- Proxmox Support Team <support@proxmox.com> Thu, 9 Apr 2020 08:56:44 +0200 | |
634 | ||
e5118d9b TL |
635 | qemu-server (6.1-13) pve; urgency=medium |
636 | ||
637 | * rescan: fix call to foreach_volume | |
638 | ||
639 | * migration: fix downtime limit auto-increase | |
640 | ||
641 | * migrate: allow arbitrary source->target storage maps | |
642 | ||
643 | * migrate: always check storage permissions and content type | |
644 | ||
645 | * Include full KVM/QEMU "-cpu" parameter with live-migration and | |
646 | snapshots/suspend to allow supporting custom CPU models | |
647 | ||
648 | * fix #2318: allow phys-bits CPU setting | |
649 | ||
650 | * allow custom CPU models | |
651 | ||
652 | * config: harmonize bridge pattern to match the same limits of containers | |
653 | ||
654 | * cpu config: add upcoming EPYC-Rome CPU type | |
655 | ||
656 | -- Proxmox Support Team <support@proxmox.com> Wed, 08 Apr 2020 17:08:13 +0200 | |
657 | ||
20c1b5f0 FG |
658 | qemu-server (6.1-12) pve; urgency=medium |
659 | ||
660 | * CPUConfig: fix module load when pmxcfs is unavailable | |
661 | ||
662 | * migrate: fix replication false-positives | |
663 | ||
664 | * migrate: cleanup disk/bitmaps if 'qm start' failed | |
665 | ||
666 | * migration with targetstorage: check if target storage supports images | |
667 | ||
668 | * fix efidisks on storages with minimum sizes bigger than OVMF_VARS.fd | |
669 | ||
670 | * Implement volume-related helpers and use new foreach_volume | |
671 | ||
672 | -- Proxmox Support Team <support@proxmox.com> Mon, 30 Mar 2020 10:00:13 +0200 | |
673 | ||
82a3904e TL |
674 | qemu-server (6.1-11) pve; urgency=medium |
675 | ||
676 | * vzdump: fix regression in backups for specific storage | |
677 | ||
678 | * custom CPU models: add initial parser and verifier | |
679 | ||
680 | -- Proxmox Support Team <support@proxmox.com> Thu, 26 Mar 2020 09:00:24 +0100 | |
681 | ||
404c9007 | 682 | qemu-server (6.1-10) pve; urgency=medium |
a99b470e TL |
683 | |
684 | * version_guard: early out when major/minor version is high enough | |
685 | ||
686 | * drive-mirror: add support for incremental sync | |
687 | ||
688 | * migrate: add replication info to disk overview | |
689 | ||
690 | * migrate: add live-migration of replicated disks | |
691 | ||
404c9007 | 692 | -- Proxmox Support Team <support@proxmox.com> Wed, 25 Mar 2020 15:16:21 +0100 |
a99b470e | 693 | |
03c8cbd1 TL |
694 | qemu-server (6.1-8) pve; urgency=medium |
695 | ||
696 | * cloudinit: make genisoimage quieter, only output errors | |
697 | ||
698 | * Append newline to all QGA commands for compatibility with non standard | |
699 | conforming Apple based guest agent implementation | |
700 | ||
701 | * add experimental support for proxmox backup server | |
702 | ||
703 | * fix #2580: api/delete: drop VM from HA resources if purge is set | |
704 | ||
705 | * improve drive mirror completion over NBD during migration | |
706 | ||
707 | * add secured unix socket support for NBD storage migration | |
708 | ||
709 | * Disable memory hotplug for custom NUMA topologies and die on misaligned | |
710 | memory for hotplug | |
711 | ||
712 | -- Proxmox Support Team <support@proxmox.com> Fri, 20 Mar 2020 11:11:31 +0100 | |
713 | ||
00d83270 TL |
714 | qemu-server (6.1-7) pve; urgency=medium |
715 | ||
716 | * vzdump: always exclude efidisks from backups of machines currently not set | |
717 | to use OVMF (UEFI) | |
718 | ||
719 | * Simplify QEMU version check and require at least 3.0+ | |
720 | ||
721 | * Align size to 1 KiB bytes before doing 'qmp block_resize' | |
722 | ||
723 | * fix #2611: use correct operation when calculating the migration bandwidth | |
724 | limit | |
725 | ||
726 | * fix #2612: allow input-data in guest exec and make command optional | |
727 | ||
728 | * cpu models: add icelake-server and icelake-client | |
729 | ||
730 | * already add models from future QEMU 4.2 release | |
731 | ||
732 | * fix #2264: allow one to add a virtio-rng device for improved entropy | |
733 | bandwidth in a VM | |
734 | ||
735 | * update_disksize: also update disk size if there was no old size at all | |
736 | ||
737 | -- Proxmox Support Team <support@proxmox.com> Mon, 09 Mar 2020 19:12:16 +0100 | |
738 | ||
8541f8cd TL |
739 | qemu-server (6.1-6) pve; urgency=medium |
740 | ||
741 | * allow reading snapshot config for users with VM.Audit on a guest | |
742 | ||
743 | * fix #2566: increase scsi limit to 31 | |
744 | ||
745 | * fix #2578: check if $target is provided in clone | |
746 | ||
747 | * update QMP commands to reflect (future) depreacations and changes in QEMU | |
748 | ||
749 | * resize volume: always request new size from storage after resizing | |
750 | ||
751 | -- Proxmox Support Team <support@proxmox.com> Mon, 10 Feb 2020 06:40:43 +0100 | |
752 | ||
2dbc9ca7 TL |
753 | qemu-server (6.1-5) pve; urgency=medium |
754 | ||
755 | * Add QEMU CPU flag querying helpers | |
756 | ||
757 | * hotplug_pending: remove redundant write/load config calls | |
758 | ||
759 | * api: vm clone: unlink zombie target VM and firewall config at end of error | |
760 | cleanup | |
761 | ||
762 | * add timeout parameter to vm start API/CLI endpoint | |
763 | ||
764 | * fix #2070: vm_start: for a migrating VM, use current format of disk if | |
765 | possible | |
766 | ||
767 | * hotplug_pending: make 'ssd' option non-hotpluggable, it cannot be changed | |
768 | live on a plugged disk. | |
769 | ||
770 | -- Proxmox Support Team <support@proxmox.com> Thu, 30 Jan 2020 10:27:33 +0100 | |
771 | ||
9f4e1abf TL |
772 | qemu-server (6.1-4) pve; urgency=medium |
773 | ||
774 | * check if QEMU version is recent enough for requested machine type | |
775 | ||
776 | * suspend to disk: check and enforce more strict permissions | |
777 | ||
778 | * update disk size before local disk migration | |
779 | ||
780 | * hide very long commandline on vm_start/migrate failure | |
781 | ||
782 | * fix #2493: show QEMU errors in migration log | |
783 | ||
784 | * api/restore: do not trigger autostart-after-restored task from locked | |
785 | context | |
786 | ||
787 | -- Proxmox Support Team <support@proxmox.com> Mon, 16 Dec 2019 16:03:25 +0100 | |
788 | ||
00a2baa5 TL |
789 | qemu-server (6.1-3) pve; urgency=medium |
790 | ||
791 | * create efidisk: poll the real size after volume creation, as some storages | |
792 | need to create bigger volumes as requested, to cope with their internal | |
793 | alignment requirements. | |
794 | ||
795 | * fix #2469: fix qemu-img convert src_format detection, wrongly reverted. | |
796 | ||
797 | * fix #2510: hostpci: always check if specified device exists | |
798 | ||
799 | -- Proxmox Support Team <support@proxmox.com> Mon, 09 Dec 2019 11:44:14 +0100 | |
800 | ||
4c2f3755 TL |
801 | qemu-server (6.1-2) pve; urgency=medium |
802 | ||
803 | * api: allow one to remove (hibernation) vmstate | |
804 | ||
805 | * vzdump: log QGA FS freeze/thaw tries in task log | |
806 | ||
807 | * skip efidisk0 in hotplug | |
808 | ||
809 | -- Proxmox Support Team <support@proxmox.com> Sat, 30 Nov 2019 18:38:36 +0100 | |
810 | ||
a78d5fb9 TL |
811 | qemu-server (6.1-1) pve; urgency=medium |
812 | ||
813 | * fix #2367: do not allow snapshot with name PENDING | |
814 | ||
815 | * fix #2469: fix qemu-img convert src_format detection | |
816 | ||
817 | * implement PVE Version addition for QEMU machine allowing to introduce new | |
818 | features while keeping migration compatibility more easily | |
819 | ||
820 | -- Proxmox Support Team <support@proxmox.com> Tue, 26 Nov 2019 13:06:21 +0100 | |
821 | ||
443054f6 TL |
822 | qemu-server (6.0-17) pve; urgency=medium |
823 | ||
824 | * PCI(e) pass-through: ensure we fallback to the previous default "0000" | |
825 | domain again. | |
826 | ||
827 | -- Proxmox Support Team <support@proxmox.com> Sat, 23 Nov 2019 09:52:09 +0100 | |
828 | ||
32b2bc62 TL |
829 | qemu-server (6.0-16) pve; urgency=medium |
830 | ||
831 | * fix #2473: use of unitialized value | |
832 | ||
833 | -- Proxmox Support Team <support@proxmox.com> Fri, 22 Nov 2019 14:18:58 +0100 | |
834 | ||
b3233604 TL |
835 | qemu-server (6.0-15) pve; urgency=medium |
836 | ||
837 | * api/migration: fix autocomplete for targetstorage | |
838 | ||
839 | * add 'type' to guest agent format, allowing one to choose between VirtIO | |
840 | (default) and ISA | |
841 | ||
842 | * clone: pre-allocate cloud-init disk for destination | |
843 | ||
844 | * SPICE/QXL: tell Linux VMs that they can add up to 4 display when running | |
845 | with qemu 4.1 or newer | |
846 | ||
847 | * add support to tell showcmd helper to assume a specific forced machine | |
848 | version when assembling a command | |
849 | ||
850 | * refactor QemuServer to avoid cyclic module dependencies | |
851 | ||
852 | * fix #2436: pci: do not hardcode pci domain to 0000 | |
853 | ||
854 | * add 'tags' config option for adding meta information to a VM | |
855 | ||
856 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Nov 2019 19:41:01 +0100 | |
857 | ||
340d8b75 FG |
858 | qemu-server (6.0-14) pve; urgency=medium |
859 | ||
860 | * use PVE::DataCenterConfig, use PVE::SSHInfo, use PVE::RRD for RRD data | |
861 | ||
862 | * refactor migration IP retrieval | |
863 | ||
864 | * add missing packages to (build-)dependencies | |
865 | ||
866 | * fix #2457: ga: set-user-password: increase maxLength of password | |
867 | ||
868 | * fix restoring old VM backups made with Promxox VE earlier than 2.3 | |
869 | ||
870 | * improve test mocking | |
871 | ||
872 | -- Proxmox Support Team <support@proxmox.com> Mon, 18 Nov 2019 12:12:03 +0100 | |
873 | ||
7be54044 TL |
874 | qemu-server (6.0-13) pve; urgency=medium |
875 | ||
876 | * fix #2434: extend machine regex to support stable release machine updates | |
877 | ||
878 | * prepare to fix #2408, #2355, #2380: use scsi-hd backend for iSCSI as well | |
879 | ||
880 | * fix deleting pending changes for not yet existing options | |
881 | ||
882 | * improve hugepage memory size detection | |
883 | ||
884 | * avoid a race for VMID reservation when importing an OVF manifest to a new | |
885 | VM | |
886 | ||
887 | * cleanup importidsk CLI command, and say to which exact disk we imported | |
888 | ||
889 | * add simple runtime heuristic for IOThread backup support, to ensure the VM | |
890 | to backup was started with a recent QEMU version. | |
891 | ||
892 | * QMPClient: ensure QMP connection is also closed in certain edge cases | |
893 | ||
894 | -- Proxmox Support Team <support@proxmox.com> Wed, 30 Oct 2019 17:43:41 +0100 | |
895 | ||
93a79238 TL |
896 | qemu-server (6.0-12) pve; urgency=medium |
897 | ||
898 | * fix regression from 6.0-10 with vmstate restore on RBD | |
899 | ||
900 | -- Proxmox Support Team <support@proxmox.com> Tue, 22 Oct 2019 16:31:46 +0200 | |
901 | ||
929bb379 TL |
902 | qemu-server (6.0-11) pve; urgency=medium |
903 | ||
904 | * fix #1071: VMs with IOThread enabled disks can now be backed up | |
905 | ||
906 | * fix regression from 6.0-10 with snapshot restore and statefile | |
907 | ||
908 | * fix regression with from 6.0-10 where forced was always assumed to be true | |
909 | for applying pending changes | |
910 | ||
911 | -- Proxmox Support Team <support@proxmox.com> Tue, 22 Oct 2019 12:50:18 +0200 | |
912 | ||
9142d2e3 | 913 | qemu-server (6.0-10) pve; urgency=medium |
90c60025 TL |
914 | |
915 | * fix #2344: ignore cloudinit in replication check | |
916 | ||
917 | * fix #1291: add option purge for vm_destroy api call | |
918 | ||
919 | * increase code re-use with pve-container for pending changes in | |
920 | configuration | |
921 | ||
922 | * fix #2412: only do the final configuration destroy after all the VMs | |
923 | resources, and references in other configurations like Firewall or resource | |
924 | pools was successfully cleaned up | |
925 | ||
926 | * fix #2171: ensure that non filesystem based statefiles get activated on VM | |
927 | start | |
928 | ||
929 | * fix #2395: improve QEMU image converter to cope better with pure file based | |
930 | sources and iSCSI source and destinations | |
931 | ||
932 | * fix #2402: allow 1GB hugepages if 2MB is unavailable | |
933 | ||
934 | * qemu 4.0 : add Cascadelake-Server and KnightsMill Intel CPU models | |
935 | ||
936 | * fix #2217: don't copy cloudinit disk on clone | |
937 | ||
9142d2e3 | 938 | -- Proxmox Support Team <support@proxmox.com> Fri, 18 Oct 2019 22:04:50 +0200 |
90c60025 | 939 | |
f1619a3b | 940 | qemu-server (6.0-9) pve; urgency=medium |
fce8336a TL |
941 | |
942 | * fix issue where a SPICE remote viewer was disconnected during live migration | |
943 | ||
944 | * Add VM reboot API/CLI integration, allowing to reboot a VM and applying any | |
945 | pending changes in-between | |
946 | ||
947 | * CPU flags: allow one to add aes flag | |
948 | ||
949 | * fix #2263: die on live migration with local cloudinit disk | |
950 | ||
951 | * fix #2041, #2272: Add Spice enhancements | |
952 | ||
953 | * Add support for more (up to 16) PCI(e) devices | |
954 | ||
955 | * usb: Allow one to make SPICE USB ports USB3 capabile | |
956 | ||
f1619a3b TL |
957 | * allow one to use USB3 for SPICE USB ports with VMs started already with |
958 | QEMU version 4.0.0, as live-migrations were not possible with this previous | |
959 | unsupported setup anyway. Live-snapshots from VMs with a SPICE USB device | |
960 | which was manually set (wasn't possible over Webinterface) to USB3 with a | |
961 | machine version of 4.0.0, need to remove the "usb3" flag again from the | |
962 | snapshot config when restoring it. | |
963 | ||
fce8336a TL |
964 | * rework kvm_user_version cache mechanism |
965 | ||
966 | * api: deletion: check also pending values for serial/usb | |
967 | ||
968 | * migration api: explicitly clear "online" flag if VM is stopped to avoid | |
969 | issues with storage migrations which are handled different for stopped VMs | |
970 | ||
971 | * abort resize disk if current size could not be determined | |
972 | ||
973 | * fix #2382: delete cloudinit disk before restoring | |
974 | ||
f1619a3b | 975 | -- Proxmox Support Team <support@proxmox.com> Thu, 26 Sep 2019 12:01:58 +0200 |
fce8336a | 976 | |
24021579 TL |
977 | qemu-server (6.0-7) pve; urgency=medium |
978 | ||
979 | * ensure new SPICE audio device works also with 'q35' based VMs | |
980 | ||
981 | -- Proxmox Support Team <support@proxmox.com> Wed, 24 Jul 2019 15:13:35 +0200 | |
982 | ||
64c197ab TL |
983 | qemu-server (6.0-6) pve; urgency=medium |
984 | ||
985 | * Add SPICE audio device support | |
986 | ||
987 | * fix #2275: die on invalid sendkey | |
988 | ||
989 | * Make sometimes problematic 'hv-tlbflush' and 'hv-evmcs' CPU flags optional | |
990 | ||
991 | -- Proxmox Support Team <support@proxmox.com> Tue, 23 Jul 2019 18:20:10 +0200 | |
992 | ||
2810c5b7 TL |
993 | qemu-server (6.0-5) pve; urgency=medium |
994 | ||
995 | * do not pass Proxmox VE internal startdate 'now' to QEMU, it does not | |
996 | understands it | |
997 | ||
998 | * use new pcie port hardware for 4.0 and newer q35 machine types | |
999 | ||
1000 | -- Proxmox Support Team <support@proxmox.com> Thu, 11 Jul 2019 19:44:28 +0200 | |
1001 | ||
fbab413d TL |
1002 | qemu-server (6.0-4) pve; urgency=medium |
1003 | ||
1004 | * fix guest shutdown if agent is configured but no timeout was passed | |
1005 | ||
1006 | * cloudinit: set iso-level in genisoimage call | |
1007 | ||
1008 | * migrate pre-condition check: add size to volume attributes and handle | |
1009 | storage not selected manually in storage config | |
1010 | ||
1011 | -- Proxmox Support Team <support@proxmox.com> Fri, 28 Jun 2019 20:35:09 +0200 | |
1012 | ||
0534c7a0 TL |
1013 | qemu-server (6.0-3) pve; urgency=medium |
1014 | ||
1015 | * do not add evmcs HyperV enlightment at all for now due to incompatibillity | |
1016 | with AMD based hosts | |
1017 | ||
1018 | -- Proxmox Support Team <support@proxmox.com> Tue, 25 Jun 2019 14:33:01 +0200 | |
1019 | ||
391b1598 TL |
1020 | qemu-server (6.0-2) pve; urgency=medium |
1021 | ||
1022 | * add migration precondition api endpoint | |
1023 | ||
1024 | * wait for possible left over VM scopes to be gone through dbus based helper | |
1025 | on VM start | |
1026 | ||
1027 | * fix #2244: Allow timeout for guest-agent shutdown | |
1028 | ||
1029 | * fix #2083: Add hv_tlbflush, hv_ipi, hv_evmcs enlightenments | |
1030 | ||
1031 | -- Proxmox Support Team <support@proxmox.com> Mon, 24 Jun 2019 17:46:51 +0200 | |
1032 | ||
29447e53 TL |
1033 | qemu-server (6.0-1) pve; urgency=medium |
1034 | ||
1035 | * SMBIOS: followup: allow now 512 characters for full format string | |
1036 | ||
1037 | * fix #2190: Base64 encode SMBIOS value strings in order to allow more | |
1038 | characters | |
1039 | ||
1040 | * allow one to add md-clear cpu flag | |
1041 | ||
1042 | * add qm command for cloudinit config dump | |
1043 | ||
1044 | * drop vnc x509 param, deprecated in 2.5 removed in 4.0 | |
1045 | ||
1046 | * Fix #1999: cli: listsnapshot: handle multiple roots and mark orphaned as | |
1047 | root | |
1048 | ||
1049 | * drop references to un-maintained sheepdog plugin | |
1050 | ||
1051 | * vm_resume: correctly honor $nocheck | |
1052 | ||
1053 | -- Proxmox Support Team <support@proxmox.com> Fri, 14 Jun 2019 20:59:07 +0200 | |
1054 | ||
e6afd9e1 | 1055 | qemu-server (6.0-0+1) pve; urgency=medium |
2b6f3c42 TL |
1056 | |
1057 | * rebuild for Debian Buster / PVE 6.0 | |
1058 | ||
e6afd9e1 | 1059 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 May 2019 19:12:34 +0200 |
2b6f3c42 | 1060 | |
0410703f TL |
1061 | qemu-server (5.0-51) unstable; urgency=medium |
1062 | ||
1063 | * fix #1811: allow non root user to edit serialX: socket entries | |
1064 | ||
1065 | * allow non root users to add spice usb port | |
1066 | ||
1067 | * fix #1829: do not ignore format parameter when creating cloudinit | |
1068 | disk volume | |
1069 | ||
1070 | * fix: #1075: Restore VM template to VM and try to convert to template | |
1071 | ||
1072 | * fix #2173: use qemu-img to check cloudinit disk existence | |
1073 | ||
1074 | * cloudinit: use detected format in volume name parsing | |
1075 | ||
1076 | -- Proxmox Support Team <support@proxmox.com> Tue, 30 Apr 2019 14:07:59 +0000 | |
1077 | ||
c68305a4 TL |
1078 | qemu-server (5.0-50) unstable; urgency=medium |
1079 | ||
1080 | * fix #2100: ignore cloudinit drive on offline migration | |
1081 | ||
1082 | * honor bandwidth limits (bwlimit) for migrate, drive-mirror, clone | |
1083 | and add to API calls | |
1084 | ||
1085 | -- Proxmox Support Team <support@proxmox.com> Thu, 04 Apr 2019 16:22:10 +0200 | |
1086 | ||
272db0fb TL |
1087 | qemu-server (5.0-49) unstable; urgency=medium |
1088 | ||
1089 | * return config lock in vm status | |
1090 | ||
1091 | * move 'pve-snapshot-name' to common | |
1092 | ||
1093 | -- Proxmox Support Team <support@proxmox.com> Thu, 21 Mar 2019 12:55:03 +0100 | |
1094 | ||
ed157803 TL |
1095 | qemu-server (5.0-48) unstable; urgency=medium |
1096 | ||
1097 | * cloud-init: allow custom network/user data files via snippets | |
1098 | ||
1099 | * fix #2120: use hosts initiator name with qemu-img | |
1100 | ||
1101 | * fix #2131: get correct device when deleting iothreads | |
1102 | ||
1103 | * config: NIC macaddr: enforce unicast MAC addresses | |
1104 | ||
1105 | * implement suspend to disk for running VMs over API and CLI | |
1106 | ||
1107 | -- Proxmox Support Team <support@proxmox.com> Tue, 19 Mar 2019 13:25:38 +0100 | |
1108 | ||
0a6f7cc6 TL |
1109 | qemu-server (5.0-47) unstable; urgency=medium |
1110 | ||
1111 | * fix #2043: always stop existing systemd scopes on VM start | |
1112 | ||
1113 | * use nr_hugepages from /proc/cmdline | |
1114 | ||
1115 | * fix #2101: cloudinit: IPv6 ending in : not parsed as a string | |
1116 | ||
1117 | * fix #1891: Add zsh command completion for qm and qmrestore | |
1118 | ||
1119 | * fix #2097: allow one to set and pass the WWN parameter for IDE, SATA and | |
1120 | SCSI disks | |
1121 | ||
1122 | * allow one to add IVSHMEM device to a VM configuration | |
1123 | ||
1124 | * fix #2114: always set correct link status on VM network adapter hotplug | |
1125 | ||
1126 | -- Proxmox Support Team <support@proxmox.com> Mon, 04 Mar 2019 10:11:00 +0100 | |
1127 | ||
a60ba460 TL |
1128 | qemu-server (5.0-46) unstable; urgency=medium |
1129 | ||
1130 | * allow explicit hv-vendor-id | |
1131 | ||
1132 | * allow explicit set vga with gpu passthrough | |
1133 | ||
1134 | * fix #1924: add snapshot parameter | |
1135 | ||
1136 | * allow to add pre- start/stop hook scripts | |
1137 | ||
1138 | -- Proxmox Support Team <support@proxmox.com> Fri, 01 Feb 2019 13:04:19 +0100 | |
1139 | ||
15147c74 TL |
1140 | qemu-server (5.0-45) unstable; urgency=medium |
1141 | ||
1142 | * fix #2003: give qm terminal a terminal over ssh | |
1143 | ||
1144 | * migrate: fix local disk migration with online VMs | |
1145 | ||
1146 | -- Proxmox Support Team <support@proxmox.com> Mon, 21 Jan 2019 10:42:03 +0100 | |
1147 | ||
b74f5794 TL |
1148 | qemu-server (5.0-44) unstable; urgency=medium |
1149 | ||
1150 | * fix #1013 : migrate : sync_disk : --targetstorage with offline disk | |
1151 | ||
1152 | * add Windows 7 PCIe quirk for adding 'hostpci' devices | |
1153 | ||
1154 | * fix #2032: check that type is set before assembling a VGA device | |
1155 | ||
1156 | * add configuration to command regression tests | |
1157 | ||
1158 | * allow 'none' as VGA option | |
1159 | ||
1160 | * fix #1267: move args to the end of qemu commandline | |
1161 | ||
1162 | * clone_disk : cloudinit drive: don't clone snapshot name (snapname) | |
1163 | ||
1164 | -- Proxmox Support Team <support@proxmox.com> Thu, 20 Dec 2018 10:17:47 +0100 | |
1165 | ||
e6bac1f5 TL |
1166 | qemu-server (5.0-43) unstable; urgency=medium |
1167 | ||
1168 | * usb: fix check if machine type is q35 | |
1169 | ||
1170 | * qm cleanup: exit silently if VM config does not belong to node | |
1171 | anymore | |
1172 | ||
1173 | -- Proxmox Support Team <support@proxmox.com> Thu, 29 Nov 2018 12:57:49 +0100 | |
1174 | ||
8794aa34 TL |
1175 | qemu-server (5.0-42) unstable; urgency=medium |
1176 | ||
1177 | * add mediated devices support | |
1178 | ||
1179 | * use improved lspci | |
1180 | ||
1181 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Nov 2018 11:22:04 +0100 | |
1182 | ||
e196200a TL |
1183 | qemu-server (5.0-41) unstable; urgency=medium |
1184 | ||
1185 | * fix #1959: add fallback for auto previously set by SLAAC | |
1186 | ||
1187 | * create_vm: don't add vmgenid for ARM machines by default | |
1188 | ||
1189 | * use qmeventd to execute qm cleanup | |
1190 | ||
1191 | * QemuServer: remove PCI sysfs helpers | |
1192 | ||
1193 | -- Proxmox Support Team <support@proxmox.com> Mon, 19 Nov 2018 14:38:42 +0100 | |
1194 | ||
56cd7f69 TL |
1195 | qemu-server (5.0-40) unstable; urgency=medium |
1196 | ||
1197 | * correctly check display vga type | |
1198 | ||
1199 | -- Proxmox Support Team <support@proxmox.com> Mon, 12 Nov 2018 17:27:53 +0100 | |
1200 | ||
d0f6e150 TL |
1201 | qemu-server (5.0-39) unstable; urgency=medium |
1202 | ||
1203 | * Add `ssd` property to IDE, SATA, and SCSI drives | |
1204 | ||
1205 | * fix #1952: make vga memory configurable | |
1206 | ||
c0c7dc79 TL |
1207 | * fix #1969: increase max unused disks |
1208 | ||
1209 | -- Proxmox Support Team <support@proxmox.com> Fri, 09 Nov 2018 16:23:26 +0100 | |
d0f6e150 | 1210 | |
5795e618 WB |
1211 | qemu-server (5.0-38) unstable; urgency=medium |
1212 | ||
1213 | * add second qmp socket when running qemu >= 2.12 for pending event/reboot | |
1214 | changes | |
1215 | ||
1216 | -- Proxmox Support Team <support@proxmox.com> Thu, 18 Oct 2018 12:28:49 +0200 | |
1217 | ||
458d4133 WB |
1218 | qemu-server (5.0-37) unstable; urgency=medium |
1219 | ||
1220 | * add virtio to the list of valid gpu types | |
1221 | ||
1222 | * lower qemu requirement for hv_synic and hv_stimer to 2.12 | |
1223 | ||
1224 | * prepare for deprecated functionality in qemu 3.0 | |
1225 | ||
1226 | -- Proxmox Support Team <support@proxmox.com> Tue, 16 Oct 2018 14:53:04 +0200 | |
1227 | ||
19d93db0 TL |
1228 | qemu-server (5.0-36) unstable; urgency=medium |
1229 | ||
1230 | * fix #1908: add VM Generation ID (vmgenid) device by default on new VMs and | |
1231 | allow to set on existing ones | |
1232 | ||
1233 | * fix version check in qemu_machine_feature_enabled | |
1234 | ||
1235 | * use qemu's internal blockdev-snapshot functions to avoid some issues with | |
1236 | snapshots on qcow2 files | |
1237 | ||
1238 | -- Proxmox Support Team <support@proxmox.com> Mon, 24 Sep 2018 11:14:32 +0200 | |
1239 | ||
178acded TL |
1240 | qemu-server (5.0-35) unstable; urgency=medium |
1241 | ||
1242 | * add hv_synic and hv_stimer HyperV Enlightment flags on QEMU 3.0 and later | |
1243 | ||
1244 | * improve setting QEMU machine type on snapshot and rollback | |
1245 | ||
1246 | -- Proxmox Support Team <support@proxmox.com> Mon, 17 Sep 2018 15:29:18 +0200 | |
1247 | ||
32798086 TL |
1248 | qemu-server (5.0-34) unstable; urgency=medium |
1249 | ||
1250 | * fix #1865: CloudInit doesn't add IPv6 | |
1251 | ||
1252 | * allow to add ibpb, ssbd, virt-ssbd, amd-ssbd, amd-no-ssb and pdpe1gb CPU flags | |
1253 | ||
1254 | * clone: improve message for ignoring pending changes | |
1255 | ||
1256 | -- Proxmox Support Team <support@proxmox.com> Thu, 13 Sep 2018 11:37:24 +0200 | |
1257 | ||
e27003df TL |
1258 | qemu-server (5.0-33) unstable; urgency=medium |
1259 | ||
1260 | * fix #1242: allow one to setup an automatic QEMU guest agent fstrim | |
1261 | command after cloning or moving a disk live | |
1262 | ||
1263 | * define return properties for vmstatus API call | |
1264 | ||
1265 | -- Proxmox Support Team <support@proxmox.com> Mon, 20 Aug 2018 14:40:46 +0200 | |
1266 | ||
4e09f915 TL |
1267 | qemu-server (5.0-32) unstable; urgency=medium |
1268 | ||
1269 | * api/agent: do not dereference parameter hash before passing to | |
1270 | agent_cmd method | |
1271 | ||
1272 | * api/agent: import check_agent_error method | |
1273 | ||
1274 | -- Proxmox Support Team <support@proxmox.com> Mon, 30 Jul 2018 10:55:42 +0200 | |
1275 | ||
4c4622a8 TL |
1276 | qemu-server (5.0-31) unstable; urgency=medium |
1277 | ||
1278 | * fix #1717: delete snapshot when vm running and drive not attached | |
1279 | ||
1280 | * fix qemu agent commands: add missing import of 'agent_cmd' method | |
1281 | ||
1282 | -- Proxmox Support Team <support@proxmox.com> Mon, 30 Jul 2018 10:24:27 +0200 | |
1283 | ||
c2eb7ec2 TL |
1284 | qemu-server (5.0-30) unstable; urgency=medium |
1285 | ||
1286 | * Fix SPICE multi-monitor mode on VMs using q35 machine type | |
1287 | ||
1288 | * extend QEMU guest agent API with file read/write, setting VM user password | |
1289 | and executing arbitrary commands in VM | |
1290 | ||
1291 | * add guest command group to qm CLI tool | |
1292 | ||
1293 | * add 'dryrun' to qm rescan, which only list changes but does not actually | |
1294 | saves them | |
1295 | ||
1296 | * add a workaround for bug #1650: add content type filter to rescan | |
1297 | ||
1298 | -- Proxmox Support Team <support@proxmox.com> Tue, 17 Jul 2018 11:39:01 +0200 | |
1299 | ||
dbf34697 TL |
1300 | qemu-server (5.0-29) unstable; urgency=medium |
1301 | ||
1302 | * reserve new VM config with create lock early | |
1303 | ||
1304 | * api: allow auto vm start after create finished | |
1305 | ||
1306 | * use 'system_wakeup' to resume VMs suspended by their guest OS | |
1307 | ||
1308 | -- Proxmox Support Team <support@proxmox.com> Fri, 15 Jun 2018 12:11:29 +0200 | |
1309 | ||
b8ff6fb2 TL |
1310 | qemu-server (5.0-28) unstable; urgency=medium |
1311 | ||
1312 | * cloud-init: improve handling of network settings for broken | |
1313 | versions (e.g., the one currently used by CentOS 7) | |
1314 | ||
1315 | -- Proxmox Support Team <support@proxmox.com> Mon, 11 Jun 2018 12:48:42 +0200 | |
1316 | ||
616aecc1 TL |
1317 | qemu-server (5.0-27) unstable; urgency=medium |
1318 | ||
1319 | * qm agent: check if qga service is running | |
1320 | ||
1321 | * fix #1779: vzdump: ensure guest-fsfreeze-thaw is called on error | |
1322 | ||
1323 | * fix #1780: change datacenter.conf to datacenter.cfg in description | |
1324 | ||
1325 | * fix logic of deleting balloon config property | |
1326 | ||
1327 | * activate volume for cloudinit disk | |
1328 | ||
1329 | -- Proxmox Support Team <support@proxmox.com> Tue, 05 Jun 2018 15:24:14 +0200 | |
1330 | ||
be15435a WB |
1331 | qemu-server (5.0-26) unstable; urgency=medium |
1332 | ||
1333 | * fix #1749: do not copy pending changes when cloning a vm | |
1334 | ||
1335 | * make q35 and virtio-scsi-single compatible | |
1336 | ||
1337 | * fix an issue where cleanup operations run as part of a VM's systemd scope | |
1338 | ||
1339 | * associate cloud-init options with with the VM.Config.Network permission | |
1340 | ||
1341 | -- Proxmox Support Team <support@proxmox.com> Mon, 14 May 2018 14:04:26 +0200 | |
1342 | ||
f7166640 WB |
1343 | qemu-server (5.0-25) unstable; urgency=medium |
1344 | ||
1345 | * fix #1697: only check machine type for pxe | |
1346 | ||
1347 | * fix scsi hotplug issue with q35 machines | |
1348 | ||
1349 | * fix live migration with local disk issue with nbd | |
1350 | ||
1351 | * switch to new method of passing disk serials to qemu | |
1352 | ||
1353 | * qemu-img convert: use cache=none for ZFS to not fill up the ARC | |
1354 | ||
1355 | -- Proxmox Support Team <support@proxmox.com> Fri, 13 Apr 2018 15:11:58 +0200 | |
1356 | ||
cf7b2c9e TL |
1357 | qemu-server (5.0-24) unstable; urgency=medium |
1358 | ||
1359 | * use pve-edk2-firmware for supporting OVMF | |
1360 | ||
1361 | * restore: implement rate limiting | |
1362 | ||
1363 | * stop passing default '-k' (keyboard) QEMU option from datacenter.cfg | |
1364 | ||
1365 | * create linked clones of templates by default | |
1366 | ||
1367 | * remove legacy vm_monitor_command | |
1368 | ||
1369 | * start: always stop an existing $vmid.scope | |
1370 | ||
1371 | * implement cloudinit support | |
1372 | ||
1373 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Mar 2018 09:24:08 +0100 | |
1374 | ||
799a3aa2 WB |
1375 | qemu-server (5.0-23) unstable; urgency=medium |
1376 | ||
1377 | * fix migrate cache size parameter for qemu 2.11 | |
1378 | ||
1379 | * typo fixes in migrate task log | |
1380 | ||
1381 | * depend on pve-qemu-kvm >= 2.9.1-9 | |
1382 | ||
1383 | * allow virtio-scsi+iothread controller hot-unplug | |
1384 | ||
1385 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Feb 2018 13:21:08 +0100 | |
1386 | ||
db4a1df8 WB |
1387 | qemu-server (5.0-22) unstable; urgency=medium |
1388 | ||
1389 | * fix #1664: nbd mirror: remove socat tunnel now that it is not required | |
1390 | anymore to avoid a 30s inactivity timeout | |
1391 | ||
1392 | * fix #1569: add shared flag to disks | |
1393 | ||
1394 | * fix #1662: make the 'snapshot' disk parameter work again | |
1395 | ||
1396 | * correct 'snapshot' flag description | |
1397 | ||
1398 | * CPU types: add EPYC and EPYC-IBPB | |
1399 | ||
1400 | * forward returned errors from guest-agent commands | |
1401 | ||
1402 | * add new guest-agent commands and add commands as separate api calls | |
1403 | ||
1404 | * add agent flag to vm status api call | |
1405 | ||
1406 | * clone/restore: make the smbios UUID unique if --unique is used | |
1407 | ||
1408 | * add serial:1 to vm-status when config has a serial device configured | |
1409 | ||
1410 | -- Proxmox Support Team <support@proxmox.com> Wed, 21 Feb 2018 09:56:08 +0100 | |
1411 | ||
45cc6761 WB |
1412 | qemu-server (5.0-21) unstable; urgency=medium |
1413 | ||
1414 | * fix a case where with the upcoming introduction of sub-commands the spice | |
1415 | ticket could be read from a file rather than received via stdin | |
1416 | ||
1417 | -- Proxmox Support Team <support@proxmox.com> Mon, 22 Jan 2018 15:13:23 +0100 | |
1418 | ||
332a2f2b WB |
1419 | qemu-server (5.0-20) unstable; urgency=medium |
1420 | ||
1421 | * added spec-ctrl flag to cpu 'flags' property | |
1422 | ||
1423 | * added -IBRS cpu type variants | |
1424 | ||
1425 | * added Skylake-Server cpu type | |
1426 | ||
1427 | * added --pretty option to 'qm showcmd' | |
1428 | ||
1429 | * increase start timeout when hugepages are enabled to compensate for long | |
1430 | allocation times | |
1431 | ||
1432 | -- Proxmox Support Team <support@proxmox.com> Tue, 16 Jan 2018 14:26:30 +0100 | |
1433 | ||
d40d9494 FG |
1434 | qemu-server (5.0-19) unstable; urgency=medium |
1435 | ||
1436 | * add 'flags' property to cpu option to allow passing PCID support to VMs | |
1437 | ||
1438 | * fix efi disk format detection | |
1439 | ||
1440 | * use default values from load_defaults() when none is specified in conf | |
1441 | ||
1442 | -- Proxmox Support Team <support@proxmox.com> Tue, 9 Jan 2018 15:49:35 +0100 | |
1443 | ||
ca7be996 WB |
1444 | qemu-server (5.0-18) unstable; urgency=medium |
1445 | ||
1446 | * fix #1570: fix template backup with pigz | |
1447 | ||
1448 | * fix #1471: change keyboard default to undef | |
1449 | ||
1450 | * fix efi disks in raw mode not being fully writable | |
1451 | ||
1452 | * qm terminal: add --escape option to change or disable the escape key | |
1453 | ||
1454 | * enable vncproxy with vncterm for serial ports | |
1455 | ||
1456 | * add termproxy api call | |
1457 | ||
1458 | * stop adding the same disk as unused multiple times when they are reachable | |
1459 | through multiple storage definitions | |
1460 | ||
1461 | * check if the guest agent actually runs before a fsfreeze-freeze/thaw | |
1462 | ||
1463 | * update ostype documentation | |
1464 | ||
1465 | -- Proxmox Support Team <support@proxmox.com> Wed, 13 Dec 2017 14:56:59 +0100 | |
1466 | ||
af736d4d FG |
1467 | qemu-server (5.0-17) unstable; urgency=medium |
1468 | ||
1469 | * correct cpuunits range | |
1470 | ||
1471 | * check if base volumes are unused before deleting a template | |
1472 | ||
1473 | -- Proxmox Support Team <support@proxmox.com> Tue, 17 Oct 2017 14:58:00 +0200 | |
1474 | ||
8f943606 FG |
1475 | qemu-server (5.0-16) unstable; urgency=medium |
1476 | ||
1477 | * add new qm command 'importovf', to create VMs from an OVF manifest | |
1478 | ||
1479 | * snapshot: use explicitly configured vmstate storage | |
1480 | ||
1481 | * config: add vmstatestorage option | |
1482 | ||
1483 | * VM.Snapshot.Rollback privilege added | |
1484 | ||
1485 | * migration : enable mtunnel for insecure migration | |
1486 | ||
1487 | * ovmf: deprecate old legay ovmf image and refactor | |
1488 | ||
1489 | * improve efidisk creation | |
1490 | ||
1491 | * efidisk: do not hard code efivar base image size | |
1492 | ||
1493 | * fix #1441: do not unplug controllers when the mirroring is finished | |
1494 | ||
1495 | * do not overwrite global signal handlers | |
1496 | ||
1497 | * update_vm: sort logged parameters | |
1498 | ||
1499 | * remove legacy sparsecp | |
1500 | ||
1501 | * remove unused obsolete vmtar | |
1502 | ||
1503 | * fix #1125: check for KVM support before starting VM | |
1504 | ||
1505 | -- Proxmox Support Team <support@proxmox.com> Thu, 5 Oct 2017 11:17:26 +0200 | |
1506 | ||
4d481008 WB |
1507 | qemu-server (5.0-15) unstable; urgency=medium |
1508 | ||
1509 | * reduce migration downtime | |
1510 | ||
1511 | * fix freezing logic when saving vm states | |
1512 | ||
1513 | -- Proxmox Support Team <support@proxmox.com> Mon, 07 Aug 2017 10:46:33 +0200 | |
1514 | ||
6956993e WB |
1515 | qemu-server (5.0-14) unstable; urgency=medium |
1516 | ||
1517 | * fix disk throttle parameters | |
1518 | ||
1519 | * improve compatibility when live-migrating from pve-4 | |
1520 | ||
1521 | -- Proxmox Support Team <support@proxmox.com> Mon, 17 Jul 2017 11:17:53 +0200 | |
1522 | ||
0a736d5c DM |
1523 | qemu-server (5.0-13) unstable; urgency=medium |
1524 | ||
1525 | * Fix #1417: make sure the target storage allows disk images before importing | |
1526 | ||
1527 | -- Proxmox Support Team <support@proxmox.com> Thu, 13 Jul 2017 06:48:43 +0200 | |
1528 | ||
c83ad586 DM |
1529 | qemu-server (5.0-12) unstable; urgency=medium |
1530 | ||
1531 | * Use default values when memory is not set in vm.conf when migrating | |
1532 | ||
1533 | -- Proxmox Support Team <support@proxmox.com> Mon, 03 Jul 2017 14:39:25 +0200 | |
1534 | ||
9fea7ca3 WB |
1535 | qemu-server (5.0-11) unstable; urgency=medium |
1536 | ||
1537 | * Fix #1417: properly check for 'images' content type when allocating disks | |
1538 | ||
1539 | -- Proxmox Support Team <support@proxmox.com> Fri, 30 Jun 2017 09:33:17 +0200 | |
1540 | ||
5f54c8d4 DM |
1541 | qemu-server (5.0-10) unstable; urgency=medium |
1542 | ||
1543 | * don't use cirrus by default for sane OS' | |
1544 | ||
1545 | * replication: remove guest states to ensure no old states are exists | |
1546 | ||
1547 | * allow disks on shared storages on replicated VMs | |
1548 | ||
1549 | * refuse to add non-replicatable disks to replicating VMs | |
1550 | ||
1551 | * config: has_feature() take default for backup into account | |
1552 | ||
1553 | -- Proxmox Support Team <support@proxmox.com> Wed, 28 Jun 2017 13:26:38 +0200 | |
1554 | ||
806e6e37 DM |
1555 | qemu-server (5.0-9) unstable; urgency=medium |
1556 | ||
1557 | * migrate: use 'mtunnel' from pvecm | |
1558 | ||
1559 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Jun 2017 11:01:15 +0200 | |
1560 | ||
c7c2d0a7 DM |
1561 | qemu-server (5.0-8) unstable; urgency=medium |
1562 | ||
1563 | * migrate: pass the with_snapshots parameter | |
1564 | ||
1565 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Jun 2017 12:58:33 +0200 | |
1566 | ||
3e5c89c1 DM |
1567 | qemu-server (5.0-7) unstable; urgency=medium |
1568 | ||
1569 | * PVE/QemuMigrate.pm: use new replication job helpers from AbstractMigrate | |
1570 | ||
1571 | * Change target in replication-state when replication direction is switched | |
1572 | ||
1573 | * PVE/QemuMigrate.pm: use replication job, transfer replication state | |
1574 | ||
1575 | * add regression tests for get_replicatable_volumes | |
1576 | ||
1577 | * get_replicatable_volumes: fix CDROM and local file/device handling | |
1578 | ||
1579 | * get_replicatable_volumes: add unused volumes | |
1580 | ||
1581 | * get_replicatable_volumes: skip volumes if we do not 'own' them | |
1582 | ||
1583 | * PVE::QemuServer::foreach_volid - pass $attr hash to callback | |
1584 | ||
1585 | * get_replicatable_volumes: skip volumes on shared storage | |
1586 | ||
1587 | * PVE/API2/Qemu.pm: aquire guest_migration_lock inside worker | |
1588 | ||
1589 | * Add a migration lock to avoid a replication on rollback-time | |
1590 | ||
1591 | * change from dpkg-deb to dpkg-buildpackage | |
1592 | ||
1593 | * fix #1405: sort pci ids by functions | |
1594 | ||
1595 | * Add new qm command 'importdisk' to import external disk images | |
1596 | ||
1597 | * migration: implement insecure offline migration | |
1598 | ||
1599 | * check also pending changes when reverting/deleting | |
1600 | ||
1601 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Jun 2017 08:50:45 +0200 | |
1602 | ||
77b4c607 DM |
1603 | qemu-server (5.0-6) unstable; urgency=medium |
1604 | ||
1605 | * fix burst length parameter names and pass them to qemu | |
1606 | ||
1607 | * fix #1229: more explicit spice port allocation | |
1608 | ||
df5c1139 | 1609 | * migrate: acquire guest_migration_lock during migration |
77b4c607 DM |
1610 | |
1611 | * do not allow destroy if there are replication jobs | |
1612 | ||
1613 | * use new PVE::ReplicationConfig class | |
1614 | ||
1615 | * improve error on '{full, linked} clone not available' error | |
1616 | ||
1617 | * Fix #1384: add missing decrement to calculation of socket-id | |
1618 | ||
1619 | * migrate: pass ssh_info to storage_migrate | |
1620 | ||
1621 | * tests: fix broken snapshot create tests | |
1622 | ||
1623 | * tests: fix broken snapshot delete tests | |
1624 | ||
1625 | * use ReuseAddr for vncproxy | |
1626 | ||
1627 | * Fix #1361: create disk: stricter parsing of storage:size | |
1628 | ||
1629 | * PVE::QemuServer::create_disks - run code inside eval | |
1630 | ||
1631 | * implement get_replicatable_volumes | |
1632 | ||
1633 | * add description of read/writes statistics in vzdump output | |
1634 | ||
1635 | * start vncproxy worker in the background | |
1636 | ||
1637 | -- Proxmox Support Team <support@proxmox.com> Wed, 31 May 2017 09:21:27 +0200 | |
1638 | ||
680bacb4 WB |
1639 | qemu-server (5.0-5) unstable; urgency=medium |
1640 | ||
1641 | * added rerror option to scsi drives | |
1642 | ||
1643 | * added storage replication settings | |
1644 | ||
1645 | -- Proxmox Support Team <support@proxmox.com> Fri, 28 Apr 2017 14:02:08 +0200 | |
1646 | ||
84e85ac1 WB |
1647 | qemu-server (5.0-4) unstable; urgency=medium |
1648 | ||
1649 | * fix target storage availability check for live migration with local | |
1650 | storage | |
1651 | ||
1652 | -- Proxmox Support Team <support@proxmox.com> Fri, 21 Apr 2017 12:05:58 +0200 | |
1653 | ||
2d719468 WB |
1654 | qemu-server (5.0-3) unstable; urgency=medium |
1655 | ||
1656 | * fix vnc connections showing false errors | |
1657 | ||
1658 | * fix #1338: handle writer count limit in live migration with local disks | |
1659 | with qemu 2.9 | |
1660 | ||
1661 | -- Proxmox Support Team <support@proxmox.com> Fri, 21 Apr 2017 11:47:07 +0200 | |
1662 | ||
29987378 FG |
1663 | qemu-server (5.0-2) unstable; urgency=medium |
1664 | ||
1665 | * fix drive mirror readyness check | |
1666 | ||
1667 | * fix uninitialized warning when deleting unset VM option | |
1668 | ||
1669 | -- Proxmox Support Team <support@proxmox.com> Mon, 10 Apr 2017 16:27:59 +0200 | |
1670 | ||
36ca08b7 WB |
1671 | qemu-server (5.0-1) unstable; urgency=medium |
1672 | ||
1673 | * bump version for stretch | |
1674 | ||
1675 | -- Proxmox Support Team <support@proxmox.com> Mon, 13 Mar 2017 11:59:35 +0100 | |
1676 | ||
0d830d24 WB |
1677 | qemu-server (4.0-109) unstable; urgency=medium |
1678 | ||
1679 | * drop netcat6 dependency | |
1680 | ||
1681 | * fix a case where VMs refuse to start with scsi disk ids >= 7 | |
1682 | ||
1683 | * add skylake to cpu models | |
1684 | ||
1685 | * improve error messages | |
1686 | ||
1687 | -- Proxmox Support Team <support@proxmox.com> Mon, 13 Mar 2017 11:56:14 +0100 | |
1688 | ||
2e44a8c8 WB |
1689 | qemu-server (4.0-109) unstable; urgency=medium |
1690 | ||
1691 | * schema updates | |
1692 | ||
1693 | -- Proxmox Support Team <support@proxmox.com> Thu, 09 Feb 2017 11:40:53 +0100 | |
1694 | ||
17ada5be WB |
1695 | qemu-server (4.0-108) unstable; urgency=medium |
1696 | ||
1697 | * #1260: convert moved template disk to base | |
1698 | ||
1699 | * change TLS cipher suite to HIGH for spiceterm | |
1700 | ||
1701 | -- Proxmox Support Team <support@proxmox.com> Tue, 31 Jan 2017 13:54:42 +0100 | |
1702 | ||
e7032e9e FG |
1703 | qemu-server (4.0-107) unstable; urgency=medium |
1704 | ||
1705 | * add dependency on libpve-guest-common-perl | |
1706 | ||
1707 | * add dependency on libpve-common-perl | |
1708 | ||
1709 | -- Proxmox Support Team <support@proxmox.com> Wed, 25 Jan 2017 09:47:09 +0100 | |
1710 | ||
dd0ef550 DM |
1711 | qemu-server (4.0-106) unstable; urgency=medium |
1712 | ||
1713 | * only use scsi-block with explicit opt-in | |
1714 | ||
1715 | -- Proxmox Support Team <support@proxmox.com> Wed, 25 Jan 2017 09:19:20 +0100 | |
1716 | ||
17138aa6 DM |
1717 | qemu-server (4.0-105) unstable; urgency=medium |
1718 | ||
1719 | * use new PVE::Storage::check_volume_access() | |
1720 | ||
1721 | * Set zero $size and continue if volume_resize() returns false | |
1722 | ||
1723 | -- Proxmox Support Team <support@proxmox.com> Thu, 19 Jan 2017 09:19:45 +0100 | |
1724 | ||
be73df94 DM |
1725 | qemu-server (4.0-104) unstable; urgency=medium |
1726 | ||
1727 | * add setup_environment hook to CLIHandler classes | |
1728 | ||
1729 | * cleanup: drop superfluous condition in assignment | |
1730 | ||
1731 | * add romfile option to hostpci | |
1732 | ||
1733 | * add with-local-disks option for live storage migration | |
1734 | ||
1735 | * drive-mirror: bump timeout to 5s, add 30s inactivity timeout | |
1736 | ||
1737 | * live clone_vm: suspend or freezefs before block-job-cancel | |
1738 | ||
1739 | * add socat and unix socket for storage migration | |
1740 | ||
1741 | * add live storage migration with vm migration | |
1742 | ||
1743 | * clone live vm : add support for multiple jobs | |
1744 | ||
1745 | -- Proxmox Support Team <support@proxmox.com> Thu, 12 Jan 2017 14:15:01 +0100 | |
1746 | ||
f4c1d8e2 DM |
1747 | qemu-server (4.0-103) unstable; urgency=medium |
1748 | ||
1749 | * destroy_vm: allow vdisk_free to fail | |
1750 | ||
1751 | * Display volume size in log when doing a volume backup | |
1752 | ||
1753 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Dec 2016 12:40:40 +0100 | |
1754 | ||
3a65f4c9 DM |
1755 | qemu-server (4.0-102) unstable; urgency=medium |
1756 | ||
1757 | * avoid "No balloon device has been activated" warnings in vmstatus | |
1758 | ||
1759 | -- Proxmox Support Team <support@proxmox.com> Tue, 20 Dec 2016 10:12:55 +0100 | |
1760 | ||
4f6f7b54 FG |
1761 | qemu-server (4.0-101) unstable; urgency=medium |
1762 | ||
1763 | * allow migration of local qcow2 snapshots | |
1764 | ||
1765 | -- Proxmox Support Team <support@proxmox.com> Mon, 5 Dec 2016 12:38:54 +0100 | |
1766 | ||
e57d58e5 DM |
1767 | qemu-server (4.0-100) unstable; urgency=medium |
1768 | ||
1769 | * allow insecure migrations from older qemu-servers | |
1770 | ||
1771 | -- Proxmox Support Team <support@proxmox.com> Fri, 02 Dec 2016 18:50:54 +0100 | |
1772 | ||
1b314d19 DM |
1773 | qemu-server (4.0-99) unstable; urgency=medium |
1774 | ||
1775 | * qm agent: remove 'guest-' prefix from commands | |
1776 | ||
1777 | * qm agent: pass command as second required argument | |
1778 | ||
1779 | * qm agent: add output formatter | |
1780 | ||
1781 | -- Proxmox Support Team <support@proxmox.com> Thu, 01 Dec 2016 07:58:34 +0100 | |
1782 | ||
96e6a804 DM |
1783 | qemu-server (4.0-98) unstable; urgency=medium |
1784 | ||
1785 | * Add "qm agent" command | |
1786 | ||
1787 | * increase timeout for guest-fsfreeze-freeze | |
1788 | ||
1789 | -- Proxmox Support Team <support@proxmox.com> Wed, 30 Nov 2016 12:31:36 +0100 | |
1790 | ||
4c3a2d3b DM |
1791 | qemu-server (4.0-97) unstable; urgency=medium |
1792 | ||
1793 | * Add entry for windows 10 and 2016 support | |
1794 | ||
1795 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Nov 2016 09:09:23 +0100 | |
1796 | ||
90e1670d DM |
1797 | qemu-server (4.0-96) unstable; urgency=medium |
1798 | ||
1799 | * restrict monitor API to Sys.Modify for most commands | |
1800 | ||
1801 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 Nov 2016 10:02:37 +0100 | |
1802 | ||
cad05dcf DM |
1803 | qemu-server (4.0-95) unstable; urgency=medium |
1804 | ||
1805 | * vm_shutdown: request 'stopped' state for HA enabled VMs | |
1806 | ||
1807 | * use ha-manager 'stopped' state instead of 'disabled' | |
1808 | ||
1809 | * switch to 'ha-manager set' (instead of 'ha-manager start/stop') | |
1810 | ||
1811 | * vmstate snapshot: activate|deactivate volume | |
1812 | ||
1813 | * qemu_volume_snapshot_delete : fix krbd snapshot delete | |
1814 | ||
1815 | * VZDump/QemuServer: set bless class correctly | |
1816 | ||
1817 | * cleanup windows version handling and hyperv enlightments | |
1818 | ||
1819 | * remove unnecessary format_description properties | |
1820 | ||
1821 | * register new standard option 'pve-qm-image-format' | |
1822 | ||
1823 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 Nov 2016 08:11:08 +0100 | |
1824 | ||
bb476da6 DM |
1825 | qemu-server (4.0-94) unstable; urgency=medium |
1826 | ||
1827 | * fix docs for iops/bps_max_length throttling options | |
1828 | ||
1829 | -- Proxmox Support Team <support@proxmox.com> Thu, 03 Nov 2016 12:53:44 +0100 | |
1830 | ||
5494341a DM |
1831 | qemu-server (4.0-93) unstable; urgency=medium |
1832 | ||
1833 | * Close #1195: support iops/bps_max_length throttling options | |
1834 | ||
1835 | * fix a perl warning when failing to parse a new drive string | |
1836 | ||
1837 | * fix a warning: discard is not a number | |
1838 | ||
1839 | * fix #1177: allow dedicated migration network | |
1840 | ||
1841 | * change default value for cpuunits to 1024 | |
1842 | ||
1843 | -- Proxmox Support Team <support@proxmox.com> Thu, 03 Nov 2016 10:26:03 +0100 | |
1844 | ||
6d3ff70b DM |
1845 | qemu-server (4.0-92) unstable; urgency=medium |
1846 | ||
1847 | * Close #351: add more info to backup log | |
1848 | ||
1849 | * add qm listsnapshot call | |
1850 | ||
1851 | * snapshot_list: add bash completion for vmid | |
1852 | ||
1853 | * Fix #1174: remove pve-qm-drive | |
1854 | ||
1855 | * enable drive-mirror with iothread for qemu 2.7 v2 | |
1856 | ||
1857 | * add get_running_qemu_version | |
1858 | ||
1859 | * cpu hotplug : add new cpu hotplug method for qemu 2.7 | |
1860 | ||
1861 | * cpu hotplug : add coldplugged cpu to qemu command line | |
1862 | ||
1863 | * cpu hotplug : add print_cpu_device | |
1864 | ||
1865 | * numaX : use cpus option multiple time if cpulist | |
1866 | ||
1867 | -- Proxmox Support Team <support@proxmox.com> Fri, 21 Oct 2016 09:13:39 +0200 | |
1868 | ||
520e3973 DM |
1869 | qemu-server (4.0-91) unstable; urgency=medium |
1870 | ||
1871 | * fix #1131: activate volume before copying efidisk | |
1872 | ||
1873 | -- Proxmox Support Team <support@proxmox.com> Fri, 07 Oct 2016 08:21:19 +0200 | |
1874 | ||
e22b5f22 DM |
1875 | qemu-server (4.0-90) unstable; urgency=medium |
1876 | ||
1877 | * fix #1111: qm showcmd wrong escape sequence | |
1878 | ||
1879 | * Avoid to parse empty property string | |
1880 | ||
1881 | -- Proxmox Support Team <support@proxmox.com> Wed, 05 Oct 2016 07:13:33 +0200 | |
1882 | ||
2aa7ef3e DM |
1883 | qemu-server (4.0-89) unstable; urgency=medium |
1884 | ||
1885 | * fix manual page (use efidisk0 instead of efidisk[N]) | |
1886 | ||
1887 | -- Proxmox Support Team <support@proxmox.com> Thu, 29 Sep 2016 12:21:07 +0200 | |
1888 | ||
b8484ba0 DM |
1889 | qemu-server (4.0-88) unstable; urgency=medium |
1890 | ||
1891 | * restore: better error handling for vdisk deletion | |
1892 | ||
1893 | * forbid migration of template with local base image | |
1894 | ||
1895 | * forbid restore into existing template | |
1896 | ||
1897 | -- Proxmox Support Team <support@proxmox.com> Fri, 16 Sep 2016 07:49:45 +0200 | |
1898 | ||
7147c897 DM |
1899 | qemu-server (4.0-87) unstable; urgency=medium |
1900 | ||
1901 | * add seabios bootsplash and use it | |
1902 | ||
1903 | * add efidisk0 to config, use efidisk0 for efivars | |
1904 | ||
1905 | -- Proxmox Support Team <support@proxmox.com> Thu, 08 Sep 2016 12:34:23 +0200 | |
1906 | ||
201e618d DM |
1907 | qemu-server (4.0-86) unstable; urgency=medium |
1908 | ||
1909 | * hostpci: bring back multifunction pass-through shortcut | |
1910 | ||
1911 | * disable drive-mirror when iothread is enabled | |
1912 | ||
1913 | * hugepages: map numa node IDs to host and guest correctly | |
1914 | ||
1915 | * hugepages: use hostnodes value as numanode for topology | |
1916 | ||
1917 | * qemu-img convert : use default cache=unsafe instead writeback | |
1918 | ||
1919 | * Fix #1057: make protection a fast-plug option | |
1920 | ||
1921 | * add lock check for move_disk API call | |
1922 | ||
1923 | * deactivate new volumes after clone to other node | |
1924 | ||
1925 | * pass datacenter.cfg's mac_prefix to random_ether_addr | |
1926 | ||
1927 | -- Proxmox Support Team <support@proxmox.com> Mon, 29 Aug 2016 10:11:07 +0200 | |
1928 | ||
68913adc WB |
1929 | qemu-server (4.0-85) unstable; urgency=medium |
1930 | ||
1931 | * Fix #1051: typo: vpcus -> vcpus - so non-root users can change vcpus again | |
1932 | ||
1933 | -- Proxmox Support Team <support@proxmox.com> Mon, 11 Jul 2016 14:46:43 +0200 | |
1934 | ||
c0966fc6 WB |
1935 | qemu-server (4.0-84) unstable; urgency=medium |
1936 | ||
1937 | * fix #1046: add non-snapshotted disks as unused | |
1938 | ||
1939 | * fix #1040: warn early about moving a snapshotted disk | |
1940 | ||
1941 | * disable usb hotplug for now | |
1942 | ||
1943 | * remove old move disk snapshot check | |
1944 | ||
1945 | * improve errors when trying to migrate disks with snapshots | |
1946 | ||
1947 | -- Proxmox Support Team <support@proxmox.com> Mon, 11 Jul 2016 11:50:01 +0200 | |
1948 | ||
d9cf7188 WB |
1949 | qemu-server (4.0-83) unstable; urgency=medium |
1950 | ||
1951 | * Add hugepages option | |
1952 | ||
1953 | * Refactor various parts out of QemuServer | |
1954 | ||
1955 | * Include USB devices in vm_devices_list | |
1956 | ||
1957 | * Add usb hotplugging | |
1958 | ||
1959 | * Fix syntax in pve-q35.cfg | |
1960 | ||
120ee178 DM |
1961 | * Fix #146: add name to backup log |
1962 | ||
d9cf7188 WB |
1963 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Jun 2016 11:29:01 +0200 |
1964 | ||
062669f9 DM |
1965 | qemu-server (4.0-82) unstable; urgency=medium |
1966 | ||
1967 | * add dependency on DBus | |
1968 | ||
1969 | -- Proxmox Support Team <support@proxmox.com> Mon, 20 Jun 2016 11:48:45 +0200 | |
1970 | ||
5dddefea DM |
1971 | qemu-server (4.0-81) unstable; urgency=medium |
1972 | ||
1973 | * Add LVM and LVMThin to QemuMigration | |
1974 | ||
1975 | * add check for snapshots at migration | |
1976 | ||
1977 | -- Proxmox Support Team <support@proxmox.com> Thu, 16 Jun 2016 12:10:48 +0200 | |
1978 | ||
6b8a615b DM |
1979 | qemu-server (4.0-80) unstable; urgency=medium |
1980 | ||
1981 | * split old style pipe open call | |
1982 | ||
a6cc0b17 | 1983 | * fix #1020: remove unnecessary root check for unused disks |
63d269d7 | 1984 | |
6b8a615b DM |
1985 | -- Proxmox Support Team <support@proxmox.com> Thu, 09 Jun 2016 18:13:03 +0200 |
1986 | ||
a3f2f971 DM |
1987 | qemu-server (4.0-79) unstable; urgency=medium |
1988 | ||
1989 | * migrate: collect migration tunnel child process (avoid zombies) | |
1990 | ||
1991 | * migrate: use ssh forwarded UNIX socket tunnel | |
1992 | ||
1993 | * migrate: add some more log output | |
1994 | ||
1995 | -- Proxmox Support Team <support@proxmox.com> Fri, 03 Jun 2016 12:16:31 +0200 | |
1996 | ||
05270292 DM |
1997 | qemu-server (4.0-78) unstable; urgency=medium |
1998 | ||
1999 | * use enter_systemd_scope instead of systemd-run | |
2000 | ||
2001 | * fix #1010: whitelist options for permissions | |
2002 | ||
2003 | -- Proxmox Support Team <support@proxmox.com> Fri, 03 Jun 2016 11:42:25 +0200 | |
2004 | ||
344b2f99 DM |
2005 | qemu-server (4.0-77) unstable; urgency=medium |
2006 | ||
2007 | * do not ignore hotplug parse errors | |
2008 | ||
2009 | -- Proxmox Support Team <support@proxmox.com> Tue, 31 May 2016 12:15:55 +0200 | |
2010 | ||
b7f0df66 DM |
2011 | qemu-server (4.0-76) unstable; urgency=medium |
2012 | ||
2013 | * allow VLAN 1 tag in qemu-kvm vms | |
2014 | ||
2015 | -- Proxmox Support Team <support@proxmox.com> Wed, 18 May 2016 11:25:54 +0200 | |
2016 | ||
4b4e5680 DM |
2017 | qemu-server (4.0-75) unstable; urgency=medium |
2018 | ||
2019 | * fix #975, use new keyAlias feature. | |
2020 | ||
19333c9b FG |
2021 | * add --description to systemd scope unit |
2022 | ||
4b4e5680 DM |
2023 | -- Proxmox Support Team <support@proxmox.com> Wed, 11 May 2016 11:15:56 +0200 |
2024 | ||
33eb0993 DM |
2025 | qemu-server (4.0-74) unstable; urgency=medium |
2026 | ||
2027 | * correctly set cpu vendor | |
2028 | ||
90cc4809 DM |
2029 | * fix #971: don't activate shared storage in offline migration |
2030 | ||
2031 | * migrate: check if storage is available | |
2032 | ||
33eb0993 DM |
2033 | -- Proxmox Support Team <support@proxmox.com> Sun, 01 May 2016 09:25:06 +0200 |
2034 | ||
298fefcc DM |
2035 | qemu-server (4.0-73) unstable; urgency=medium |
2036 | ||
2037 | * restore: pass format to vma extract | |
2038 | ||
2039 | -- Proxmox Support Team <support@proxmox.com> Fri, 29 Apr 2016 09:03:12 +0200 | |
2040 | ||
3f565071 DM |
2041 | qemu-server (4.0-72) unstable; urgency=medium |
2042 | ||
2043 | * vm_start : force systemctl stop if orphan scope exist | |
2044 | ||
2045 | -- Proxmox Support Team <support@proxmox.com> Fri, 22 Apr 2016 11:09:52 +0200 | |
2046 | ||
de7c2026 DM |
2047 | qemu-server (4.0-71) unstable; urgency=medium |
2048 | ||
2049 | * Fix #643: activate volumes before resizing | |
2050 | ||
ffa42b86 DC |
2051 | * fix #947: reenable disk/cdrom passthrough |
2052 | ||
de7c2026 DM |
2053 | -- Proxmox Support Team <support@proxmox.com> Thu, 21 Apr 2016 10:34:42 +0200 |
2054 | ||
681e12ba DM |
2055 | qemu-server (4.0-70) unstable; urgency=medium |
2056 | ||
2057 | * vm_status: return more verbose HA state | |
2058 | ||
2059 | -- Proxmox Support Team <support@proxmox.com> Tue, 19 Apr 2016 09:01:24 +0200 | |
2060 | ||
ef99513e DM |
2061 | qemu-server (4.0-69) unstable; urgency=medium |
2062 | ||
2063 | * Fix #848: deactivate old volume after clone before deletion | |
2064 | ||
2065 | -- Proxmox Support Team <support@proxmox.com> Wed, 13 Apr 2016 08:24:49 +0200 | |
2066 | ||
edc10731 DM |
2067 | qemu-server (4.0-68) unstable; urgency=medium |
2068 | ||
2069 | * change shutdown behaviour on suspended vm | |
2070 | ||
2071 | -- Proxmox Support Team <support@proxmox.com> Tue, 12 Apr 2016 17:19:20 +0200 | |
2072 | ||
82b82b91 DM |
2073 | qemu-server (4.0-67) unstable; urgency=medium |
2074 | ||
2075 | * use pve-doc-generator to generate man pages | |
2076 | ||
2077 | -- Proxmox Support Team <support@proxmox.com> Fri, 08 Apr 2016 07:37:16 +0200 | |
2078 | ||
bee1e0ad DM |
2079 | qemu-server (4.0-66) unstable; urgency=medium |
2080 | ||
2081 | * use generic property string parser | |
2082 | ||
2083 | * drive schema: allow 'none' again | |
2084 | ||
2085 | -- Proxmox Support Team <support@proxmox.com> Fri, 01 Apr 2016 09:33:16 +0200 | |
2086 | ||
c7c16256 DM |
2087 | qemu-server (4.0-65) unstable; urgency=medium |
2088 | ||
2089 | * cfg: use the 'urlencoded' format for drive model and serial | |
2090 | ||
5572d53e DM |
2091 | * clone: use the zeroinit filter for sparseinit storages |
2092 | ||
c7c16256 DM |
2093 | -- Proxmox Support Team <support@proxmox.com> Mon, 21 Mar 2016 09:09:07 +0100 |
2094 | ||
a9920f48 DM |
2095 | qemu-server (4.0-64) unstable; urgency=medium |
2096 | ||
2097 | * Use AbstractConfig for Qemu | |
2098 | ||
6a9f1025 DM |
2099 | * fix #909: pass rate to tap_plug() |
2100 | ||
a9920f48 DM |
2101 | -- Proxmox Support Team <support@proxmox.com> Tue, 08 Mar 2016 11:43:28 +0100 |
2102 | ||
2b5c0c43 DM |
2103 | qemu-server (4.0-63) unstable; urgency=medium |
2104 | ||
2105 | * only perform scsi inquiry on device nodes | |
2106 | ||
2107 | -- Proxmox Support Team <support@proxmox.com> Sat, 27 Feb 2016 10:20:50 +0100 | |
2108 | ||
2fa6af2a DM |
2109 | qemu-server (4.0-62) unstable; urgency=medium |
2110 | ||
2111 | * fix undefined value when starting a q35 machine VM | |
2112 | ||
2113 | * kvm_user_version: update code to use our framework | |
2114 | ||
2115 | * Refactor has_feature | |
2116 | ||
2117 | -- Proxmox Support Team <support@proxmox.com> Fri, 26 Feb 2016 17:02:34 +0100 | |
2118 | ||
5be9e310 DM |
2119 | qemu-server (4.0-61) unstable; urgency=medium |
2120 | ||
2121 | * clone_vm : only deactivate sources volume if source vm if offline | |
2122 | ||
e03d994e DM |
2123 | * Refactor snapshot_create to match LXC.pm |
2124 | ||
5be9e310 DM |
2125 | -- Proxmox Support Team <support@proxmox.com> Thu, 25 Feb 2016 08:48:59 +0100 |
2126 | ||
2f151adc DM |
2127 | qemu-server (4.0-60) unstable; urgency=medium |
2128 | ||
2129 | * change check for write-zeros | |
2130 | ||
2131 | -- Proxmox Support Team <support@proxmox.com> Wed, 24 Feb 2016 17:19:12 +0100 | |
2132 | ||
5abfaf2d DM |
2133 | qemu-server (4.0-59) unstable; urgency=medium |
2134 | ||
2135 | * qemu_machine_pxe : return $machine if no pxe | |
2136 | ||
2137 | -- Proxmox Support Team <support@proxmox.com> Mon, 22 Feb 2016 17:37:11 +0100 | |
2138 | ||
a658e7af DM |
2139 | qemu-server (4.0-58) unstable; urgency=medium |
2140 | ||
2141 | * deactivate volumes if vm start command fails | |
2142 | ||
2143 | -- Proxmox Support Team <support@proxmox.com> Sat, 20 Feb 2016 10:26:28 +0100 | |
2144 | ||
07ca4ceb DM |
2145 | qemu-server (4.0-57) unstable; urgency=medium |
2146 | ||
2147 | * delete ram state files when restoring a backup | |
2148 | ||
2149 | * Refactor snapshot code | |
2150 | ||
2151 | * disable vnc server and add -nographic is no vga card is present | |
2152 | ||
2153 | * passthrough : reenable hyperv and add hv_vendor_id for windows | |
2154 | ||
2155 | -- Proxmox Support Team <support@proxmox.com> Thu, 18 Feb 2016 12:47:51 +0100 | |
2156 | ||
ab6d771f DM |
2157 | qemu-server (4.0-56) unstable; urgency=medium |
2158 | ||
2159 | * If we freeze the fs with the Qemu-Guest-Agent test if QGA is running. | |
2160 | ||
2161 | -- Proxmox Support Team <support@proxmox.com> Mon, 15 Feb 2016 12:51:19 +0100 | |
2162 | ||
a3683dfb DM |
2163 | qemu-server (4.0-55) unstable; urgency=medium |
2164 | ||
2165 | * improve usb config parsing | |
2166 | ||
3f74d8a1 DM |
2167 | * Refactor update_config_nolock -> write_config |
2168 | ||
a3683dfb DM |
2169 | -- Proxmox Support Team <support@proxmox.com> Fri, 12 Feb 2016 12:07:56 +0100 |
2170 | ||
a2e698e7 DM |
2171 | qemu-server (4.0-54) unstable; urgency=medium |
2172 | ||
2173 | * restore: deal with new backup=0 property string | |
2174 | ||
2175 | * add usb3 option for usb-devices | |
2176 | ||
2177 | -- Proxmox Support Team <support@proxmox.com> Wed, 10 Feb 2016 17:49:19 +0100 | |
2178 | ||
626cfd00 DM |
2179 | qemu-server (4.0-53) unstable; urgency=medium |
2180 | ||
2181 | * pass $skiplock all the way through to destroy_vm | |
2182 | ||
2183 | -- Proxmox Support Team <support@proxmox.com> Mon, 08 Feb 2016 11:53:03 +0100 | |
2184 | ||
031a1661 DM |
2185 | qemu-server (4.0-52) unstable; urgency=medium |
2186 | ||
2187 | * close tunnel after migration is finish. | |
2188 | ||
2189 | -- Proxmox Support Team <support@proxmox.com> Tue, 02 Feb 2016 18:16:47 +0100 | |
2190 | ||
09a25cb0 DM |
2191 | qemu-server (4.0-51) unstable; urgency=medium |
2192 | ||
2193 | * Fix #878: disk-size format | |
2194 | ||
2195 | * Fix #879: exclusion of disk for backup | |
2196 | ||
2197 | -- Proxmox Support Team <support@proxmox.com> Fri, 29 Jan 2016 10:04:41 +0100 | |
2198 | ||
52237a78 DM |
2199 | qemu-server (4.0-50) unstable; urgency=medium |
2200 | ||
2201 | * add hidden option to cpu type | |
2202 | ||
67e48d94 DM |
2203 | * fix PVE::HA use clause so HA resources get registered |
2204 | ||
3457d090 WL |
2205 | * Create firewall dir on VM restore |
2206 | ||
52237a78 DM |
2207 | -- Proxmox Support Team <support@proxmox.com> Tue, 26 Jan 2016 16:57:43 +0100 |
2208 | ||
f9eb6658 DM |
2209 | qemu-server (4.0-49) unstable; urgency=medium |
2210 | ||
2211 | * increase version to update test environment | |
2212 | ||
2213 | -- Proxmox Support Team <support@proxmox.com> Tue, 26 Jan 2016 12:50:07 +0100 | |
2214 | ||
17b9763d DM |
2215 | qemu-server (4.0-48) unstable; urgency=medium |
2216 | ||
2217 | * use safe_string_ne for trunks | |
2218 | ||
2219 | -- Proxmox Support Team <support@proxmox.com> Mon, 18 Jan 2016 16:58:23 +0100 | |
2220 | ||
ec69f46c DM |
2221 | qemu-server (4.0-47) unstable; urgency=medium |
2222 | ||
2223 | * add support for network trunks | |
2224 | ||
2225 | -- Proxmox Support Team <support@proxmox.com> Fri, 15 Jan 2016 17:27:32 +0100 | |
2226 | ||
c933c955 DM |
2227 | qemu-server (4.0-46) unstable; urgency=medium |
2228 | ||
2229 | * Closes #787: add Haswell-noTSX and Broadwell-noTSX cpu types | |
2230 | ||
2231 | -- Proxmox Support Team <support@proxmox.com> Wed, 13 Jan 2016 16:42:05 +0100 | |
2232 | ||
a7649ef5 DM |
2233 | qemu-server (4.0-45) unstable; urgency=medium |
2234 | ||
2235 | * io throttle: pass pool parameters (*_max) | |
2236 | ||
2237 | -- Proxmox Support Team <support@proxmox.com> Wed, 13 Jan 2016 06:17:52 +0100 | |
2238 | ||
9b1e4b7d DM |
2239 | qemu-server (4.0-44) unstable; urgency=medium |
2240 | ||
2241 | * ovmf : don't pass x-vga to vfio-pci | |
2242 | ||
2243 | * check for quorum when starting a VM | |
2244 | ||
2245 | -- Proxmox Support Team <support@proxmox.com> Sun, 10 Jan 2016 15:11:43 +0100 | |
2246 | ||
2bbb7bc5 DM |
2247 | qemu-server (4.0-43) unstable; urgency=medium |
2248 | ||
2249 | * disable hyper-v enlightment when xvga is enabled | |
2250 | ||
2251 | -- Proxmox Support Team <support@proxmox.com> Mon, 04 Jan 2016 06:26:31 +0100 | |
2252 | ||
4c85e7e2 DM |
2253 | qemu-server (4.0-42) unstable; urgency=medium |
2254 | ||
2255 | * add detect_zeroes option | |
2256 | ||
2257 | -- Proxmox Support Team <support@proxmox.com> Fri, 18 Dec 2015 09:20:18 +0100 | |
2258 | ||
b944d5ed DM |
2259 | qemu-server (4.0-41) unstable; urgency=medium |
2260 | ||
2261 | * add new option to select BIOS (--bios <seabios|ovmf>) | |
2262 | ||
77019edf WB |
2263 | * fix bug #841: replace get_used_paths with is_volume_in_use |
2264 | ||
b944d5ed DM |
2265 | -- Proxmox Support Team <support@proxmox.com> Thu, 10 Dec 2015 11:15:23 +0100 |
2266 | ||
8a0ebc14 DM |
2267 | qemu-server (4.0-40) unstable; urgency=medium |
2268 | ||
2269 | * qm: Add VMID auto completion to some commands | |
2270 | ||
2271 | -- Proxmox Support Team <support@proxmox.com> Wed, 09 Dec 2015 12:22:25 +0100 | |
2272 | ||
75e7ef74 DM |
2273 | qemu-server (4.0-39) unstable; urgency=medium |
2274 | ||
1b2761c0 WB |
2275 | * fix bug #828: activate disks before hotplugging them |
2276 | ||
75e7ef74 DM |
2277 | * fix bug #783: set KillMode=none, so that systemd don't kill |
2278 | them at shutdown | |
2279 | ||
54c07a93 DM |
2280 | * reenable steal time |
2281 | ||
0e3f6af5 DM |
2282 | * backup/restore firewall config with vzdump |
2283 | ||
75e7ef74 DM |
2284 | -- Proxmox Support Team <support@proxmox.com> Tue, 24 Nov 2015 16:50:11 +0100 |
2285 | ||
03575e8a DM |
2286 | qemu-server (4.0-38) unstable; urgency=medium |
2287 | ||
2288 | * Don't treat serial devices as a local resource if they | |
2289 | point to a socket. | |
2290 | ||
2291 | * qemu_img_convert: activate source volume | |
2292 | ||
2293 | -- Proxmox Support Team <support@proxmox.com> Fri, 13 Nov 2015 07:02:01 +0100 | |
2294 | ||
0eeafe9f DM |
2295 | qemu-server (4.0-37) unstable; urgency=medium |
2296 | ||
2297 | * add pve-bridge-hotplug script | |
2298 | ||
2299 | -- Proxmox Support Team <support@proxmox.com> Fri, 06 Nov 2015 16:24:44 +0100 | |
2300 | ||
ffb88d68 DM |
2301 | qemu-server (4.0-36) unstable; urgency=medium |
2302 | ||
2303 | * use qom-get to check if old pxe network rom file are used | |
2304 | ||
2305 | * migration: improve ipv6 case | |
2306 | ||
2307 | -- Proxmox Support Team <support@proxmox.com> Fri, 06 Nov 2015 07:56:14 +0100 | |
2308 | ||
568c18b4 DM |
2309 | qemu-server (4.0-35) unstable; urgency=medium |
2310 | ||
2311 | * clone: use a fullclone hash instead of $drive->{full} | |
2312 | ||
2313 | -- Proxmox Support Team <support@proxmox.com> Fri, 30 Oct 2015 07:06:47 +0100 | |
2314 | ||
db0c3594 | 2315 | qemu-server (4.0-34) unstable; urgency=medium |
091936e5 DM |
2316 | |
2317 | * use old netdevice bios files for older machine types (<= 2.4) | |
2318 | ||
2319 | -- Proxmox Support Team <support@proxmox.com> Wed, 28 Oct 2015 09:08:49 +0100 | |
2320 | ||
095df9ef DM |
2321 | qemu-server (4.0-31) unstable; urgency=medium |
2322 | ||
2323 | * migrate : add nocheck for resume | |
2324 | ||
2325 | -- Proxmox Support Team <support@proxmox.com> Thu, 15 Oct 2015 12:41:43 +0200 | |
2326 | ||
9accf2d7 DM |
2327 | qemu-server (4.0-30) unstable; urgency=medium |
2328 | ||
2329 | * qmrestore: implement bash completion | |
2330 | ||
2331 | * create: add better check for unused IDs | |
2332 | ||
2333 | -- Proxmox Support Team <support@proxmox.com> Mon, 05 Oct 2015 13:13:07 +0200 | |
2334 | ||
0e14d632 DM |
2335 | qemu-server (4.0-29) unstable; urgency=medium |
2336 | ||
2337 | * support serial numbers and models for disks | |
2338 | ||
2339 | -- Proxmox Support Team <support@proxmox.com> Wed, 30 Sep 2015 10:56:30 +0200 | |
2340 | ||
2b8badff DM |
2341 | qemu-server (4.0-28) unstable; urgency=medium |
2342 | ||
2343 | * disable kvm_steal_time, because it's currently buggy with live migration | |
2344 | ||
2345 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Sep 2015 07:14:44 +0200 | |
2346 | ||
e339fd34 DM |
2347 | qemu-server (4.0-27) unstable; urgency=medium |
2348 | ||
2349 | * allow to change boot order with VM.Config.Options privileges | |
2350 | ||
2351 | -- Proxmox Support Team <support@proxmox.com> Sat, 26 Sep 2015 11:07:11 +0200 | |
2352 | ||
073370c3 DM |
2353 | qemu-server (4.0-26) unstable; urgency=medium |
2354 | ||
2355 | * migration: disable compress (already default) | |
2356 | ||
2357 | * migration: enable xbzrle | |
2358 | ||
2359 | -- Proxmox Support Team <support@proxmox.com> Fri, 25 Sep 2015 17:59:30 +0200 | |
2360 | ||
806873a1 DM |
2361 | qemu-server (4.0-25) unstable; urgency=medium |
2362 | ||
2363 | * fix kvm version parser for CVE stable releases | |
2364 | ||
2365 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 Sep 2015 11:48:09 +0200 | |
2366 | ||
cd811472 DM |
2367 | qemu-server (4.0-24) unstable; urgency=medium |
2368 | ||
2369 | * improve VM protection mode | |
2370 | ||
2371 | * pci passthough : make vfio default | |
2372 | ||
2373 | * fix error message: allocate to much v-CPUs | |
2374 | ||
2375 | -- Proxmox Support Team <support@proxmox.com> Mon, 21 Sep 2015 12:28:19 +0200 | |
2376 | ||
4723d267 DM |
2377 | qemu-server (4.0-23) unstable; urgency=medium |
2378 | ||
2379 | * destroy: avoid warning about undefined 'protection' value | |
2380 | ||
2381 | -- Proxmox Support Team <support@proxmox.com> Thu, 10 Sep 2015 09:38:30 +0200 | |
2382 | ||
08bd2b0c DM |
2383 | qemu-server (4.0-22) unstable; urgency=medium |
2384 | ||
2385 | * add possibility to restore backup on rbd in krbd mode | |
2386 | ||
2387 | * add krbd support to online snapshot | |
2388 | ||
2389 | -- Proxmox Support Team <support@proxmox.com> Wed, 09 Sep 2015 07:55:31 +0200 | |
2390 | ||
a877c65c DM |
2391 | qemu-server (4.0-21) unstable; urgency=medium |
2392 | ||
2393 | * qm: implement bash completion | |
2394 | ||
2395 | * add VM protection mode | |
2396 | ||
2397 | * fix move_disk on RBD | |
2398 | ||
2399 | * add HA resources check before destroying a VM | |
2400 | ||
2401 | -- Proxmox Support Team <support@proxmox.com> Tue, 08 Sep 2015 10:51:05 +0200 | |
2402 | ||
8708ff33 DM |
2403 | qemu-server (4.0-20) unstable; urgency=medium |
2404 | ||
2405 | * fix start kvm with os type 'other' | |
2406 | ||
2407 | * spice console: fix 'uninitialized value in concat' due to unnamed VM | |
2408 | ||
2409 | -- Proxmox Support Team <support@proxmox.com> Fri, 28 Aug 2015 11:39:52 +0200 | |
2410 | ||
f039eff2 DM |
2411 | qemu-server (4.0-19) unstable; urgency=medium |
2412 | ||
2413 | * clone: also copy vm firewall config file | |
2414 | ||
2415 | -- Proxmox Support Team <support@proxmox.com> Tue, 25 Aug 2015 06:50:04 +0200 | |
2416 | ||
a310ea0d DM |
2417 | qemu-server (4.0-18) unstable; urgency=medium |
2418 | ||
2419 | * fix bug #688: if vm is not owner of this disk remove from config | |
2420 | ||
2421 | -- Proxmox Support Team <support@proxmox.com> Thu, 20 Aug 2015 12:30:52 +0200 | |
2422 | ||
0e4ebd30 DM |
2423 | qemu-server (4.0-17) unstable; urgency=medium |
2424 | ||
2425 | * fix bug #603: vmid.fw file not deleted | |
2426 | ||
2427 | * fix bug #517: improve error message | |
2428 | ||
2429 | * adapt /config and /pending API calls to force-delete | |
2430 | ||
2431 | -- Proxmox Support Team <support@proxmox.com> Wed, 19 Aug 2015 15:44:53 +0200 | |
2432 | ||
d7dd8b00 DM |
2433 | qemu-server (4.0-16) unstable; urgency=medium |
2434 | ||
2435 | * remove vm access permissions after destroy | |
2436 | ||
2437 | * pending-delete: remember force-deletes | |
2438 | ||
2439 | * correctly handle empty description in pending section | |
2440 | ||
2441 | -- Proxmox Support Team <support@proxmox.com> Fri, 14 Aug 2015 08:09:44 +0200 | |
2442 | ||
ef00f33b DM |
2443 | qemu-server (4.0-15) unstable; urgency=medium |
2444 | ||
2445 | * Fixed wrong UUID in Qemu VZDump backup | |
2446 | ||
2447 | * add memory_unplug support V2 | |
2448 | ||
2449 | -- Proxmox Support Team <support@proxmox.com> Thu, 30 Jul 2015 11:32:51 +0200 | |
2450 | ||
a1193279 DM |
2451 | qemu-server (4.0-14) unstable; urgency=medium |
2452 | ||
2453 | * fixed bug 662: wrong subroutine for parsing startup order | |
2454 | ||
2455 | * cpuflags : don't enforce with tcg mode | |
2456 | ||
2457 | * cpuflags : remove enforce for cpumodel=host | |
2458 | ||
2459 | * cpuflags : remove -rdtscp for Opteron cpu models | |
2460 | ||
2461 | * vzdump : abord backup if disk have iothread enabled | |
2462 | ||
2463 | -- Proxmox Support Team <support@proxmox.com> Mon, 27 Jul 2015 13:24:31 +0200 | |
2464 | ||
220c068f DM |
2465 | qemu-server (4.0-13) unstable; urgency=medium |
2466 | ||
2467 | * drive-mirror: now allow interrupts at the scanning bitmap phase | |
2468 | ||
2469 | -- Proxmox Support Team <support@proxmox.com> Wed, 01 Jul 2015 06:40:52 +0200 | |
2470 | ||
7a0f138c DM |
2471 | qemu-server (4.0-12) unstable; urgency=medium |
2472 | ||
2473 | * remove outdated host_device format | |
2474 | ||
2475 | * parse_drive: do not overwrite configured format | |
2476 | ||
2477 | * fix aio O_DIRECT check for cdrom drives | |
2478 | ||
2479 | -- Proxmox Support Team <support@proxmox.com> Wed, 10 Jun 2015 10:32:09 +0200 | |
2480 | ||
98af06a5 DM |
2481 | qemu-server (4.0-11) unstable; urgency=medium |
2482 | ||
2483 | * activate-noawait pve-api-updates | |
2484 | ||
2485 | -- Proxmox Support Team <support@proxmox.com> Mon, 01 Jun 2015 12:36:15 +0200 | |
2486 | ||
5441e51b DM |
2487 | qemu-server (4.0-10) unstable; urgency=medium |
2488 | ||
2489 | * implement cgroups through systemd-run | |
2490 | ||
2491 | * implement hotplug for cpuunits | |
2492 | ||
2493 | * remove old openvz fairscheduler code | |
2494 | ||
2495 | -- Proxmox Support Team <support@proxmox.com> Fri, 29 May 2015 08:24:33 +0200 | |
2496 | ||
14aa29d1 DM |
2497 | qemu-server (4.0-9) unstable; urgency=medium |
2498 | ||
2499 | * qmp drive-mirror : set big timeout | |
2500 | ||
2501 | * qemu-mirror : block job complete : use ready flag | |
2502 | ||
2503 | -- Proxmox Support Team <support@proxmox.com> Tue, 12 May 2015 08:19:38 +0200 | |
2504 | ||
71809558 DM |
2505 | qemu-server (4.0-8) unstable; urgency=medium |
2506 | ||
2507 | * trigger pve-api-updates event | |
2508 | ||
2509 | -- Proxmox Support Team <support@proxmox.com> Tue, 05 May 2015 14:57:55 +0200 | |
2510 | ||
8ff79ef9 DM |
2511 | qemu-server (4.0-7) unstable; urgency=medium |
2512 | ||
2513 | * cleanup: use new standard option 'pve-startup-order' | |
2514 | ||
2515 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Apr 2015 10:04:04 +0200 | |
2516 | ||
acc5d34a DM |
2517 | qemu-server (4.0-6) unstable; urgency=medium |
2518 | ||
2519 | * fix ha resource names | |
2520 | ||
2521 | -- Proxmox Support Team <support@proxmox.com> Fri, 17 Apr 2015 13:11:12 +0200 | |
2522 | ||
a9c3acda DM |
2523 | qemu-server (4.0-5) unstable; urgency=medium |
2524 | ||
2525 | * use new pve-ha-manager | |
2526 | ||
2527 | -- Proxmox Support Team <support@proxmox.com> Fri, 27 Mar 2015 12:48:41 +0100 | |
2528 | ||
c0e30388 DM |
2529 | qemu-server (4.0-4) unstable; urgency=medium |
2530 | ||
2531 | * add qemu cpu flags optimisations for kernel 3.10 | |
2532 | ||
2533 | -- Proxmox Support Team <support@proxmox.com> Tue, 17 Mar 2015 08:58:56 +0100 | |
2534 | ||
8586d0ec DM |
2535 | qemu-server (4.0-3) unstable; urgency=medium |
2536 | ||
2537 | * vmstatus: use vcpus if defined | |
2538 | ||
ced6ed82 DM |
2539 | * balloon: use qom-get for guest balloon statistics |
2540 | ||
8586d0ec DM |
2541 | -- Proxmox Support Team <support@proxmox.com> Mon, 09 Mar 2015 08:22:47 +0100 |
2542 | ||
130236ff DM |
2543 | qemu-server (4.0-2) unstable; urgency=medium |
2544 | ||
130236ff DM |
2545 | * drive_add: escape \ character |
2546 | ||
2547 | * bugfix: allow manual balloning if shares = 0 | |
2548 | ||
2549 | -- Proxmox Support Team <support@proxmox.com> Fri, 06 Mar 2015 10:21:52 +0100 | |
2550 | ||
6b0ddb3c DM |
2551 | qemu-server (4.0-1) unstable; urgency=medium |
2552 | ||
2553 | * updated for debian jessie | |
2554 | ||
2555 | -- Proxmox Support Team <support@proxmox.com> Fri, 27 Feb 2015 13:00:56 +0100 | |
2556 | ||
915a73d6 DM |
2557 | qemu-server (3.3-20) unstable; urgency=low |
2558 | ||
2559 | * correctly set an remove lock (fix "qm unlock") | |
2560 | ||
2561 | -- Proxmox Support Team <support@proxmox.com> Sun, 15 Feb 2015 09:05:40 +0100 | |
2562 | ||
0d750e4f DM |
2563 | qemu-server (3.3-19) unstable; urgency=low |
2564 | ||
2565 | * commit pending values when changing CDROM | |
2566 | ||
2567 | -- Proxmox Support Team <support@proxmox.com> Sat, 14 Feb 2015 09:24:03 +0100 | |
2568 | ||
66822b6a DM |
2569 | qemu-server (3.3-18) unstable; urgency=low |
2570 | ||
2571 | * bugfix : add missing queues nic option in print_net | |
2572 | ||
2573 | -- Proxmox Support Team <support@proxmox.com> Fri, 13 Feb 2015 09:05:21 +0100 | |
2574 | ||
093725e8 DM |
2575 | qemu-server (3.3-17) unstable; urgency=low |
2576 | ||
2577 | * fix CDROM hotplug | |
2578 | ||
2579 | * This fix hotplug for devices behind bridges | |
2580 | ||
2581 | * check possibility to rollback a snapshot early | |
2582 | ||
2583 | -- Proxmox Support Team <support@proxmox.com> Thu, 12 Feb 2015 08:19:02 +0100 | |
2584 | ||
a0b79d95 DM |
2585 | qemu-server (3.3-16) unstable; urgency=low |
2586 | ||
2587 | * QemuServer: fix wrong binding of pci root ports, bridges or switches | |
2588 | to vfio | |
2589 | ||
2590 | -- Proxmox Support Team <support@proxmox.com> Wed, 11 Feb 2015 06:32:14 +0100 | |
2591 | ||
3605aaa6 DM |
2592 | qemu-server (3.3-15) unstable; urgency=low |
2593 | ||
2594 | * code cleanup: add foreach_dimm sub | |
51a6f637 AD |
2595 | |
2596 | * hotplug: memory hotplug option is not hotpluggable | |
515c82a9 DM |
2597 | |
2598 | * fix bug 597: hotplug fix | |
3605aaa6 DM |
2599 | |
2600 | -- Proxmox Support Team <support@proxmox.com> Mon, 09 Feb 2015 07:05:05 +0100 | |
2601 | ||
cd969862 DM |
2602 | qemu-server (3.3-14) unstable; urgency=low |
2603 | ||
2604 | * include memory hotplug patch | |
2605 | ||
2606 | -- Proxmox Support Team <support@proxmox.com> Wed, 28 Jan 2015 07:11:10 +0100 | |
2607 | ||
d2896a14 DM |
2608 | qemu-server (3.3-13) unstable; urgency=low |
2609 | ||
2610 | * hotplug config: allow to enable specific features | |
2611 | ||
2612 | -- Proxmox Support Team <support@proxmox.com> Tue, 27 Jan 2015 12:39:21 +0100 | |
2613 | ||
a74c93d3 DM |
2614 | qemu-server (3.3-12) unstable; urgency=low |
2615 | ||
2616 | * add new vcpus option | |
2617 | ||
2618 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Jan 2015 08:04:44 +0100 | |
2619 | ||
029e4c13 DM |
2620 | qemu-server (3.3-11) unstable; urgency=low |
2621 | ||
2622 | * enable hotplug by default | |
2623 | ||
2624 | -- Proxmox Support Team <support@proxmox.com> Wed, 21 Jan 2015 08:53:10 +0100 | |
2625 | ||
e7a43f20 DM |
2626 | qemu-server (3.3-10) unstable; urgency=low |
2627 | ||
2628 | * Support additional e1000 variants for VM machines | |
25088687 DM |
2629 | |
2630 | * Add link_down flag to network config | |
e7a43f20 DM |
2631 | |
2632 | -- Proxmox Support Team <support@proxmox.com> Tue, 20 Jan 2015 07:15:48 +0100 | |
2633 | ||
6271650e DM |
2634 | qemu-server (3.3-9) unstable; urgency=low |
2635 | ||
2636 | * pending api : fix parsing 0 value | |
2637 | ||
2638 | * fix test for ballon hotplug | |
2639 | ||
2640 | * set boot strict=on to prevent booting from not listed boot devices | |
2641 | ||
2642 | -- Proxmox Support Team <support@proxmox.com> Thu, 15 Jan 2015 06:23:10 +0100 | |
2643 | ||
d14ccfd2 DM |
2644 | qemu-server (3.3-8) unstable; urgency=low |
2645 | ||
2646 | * new 'pending changes' API | |
2647 | ||
2648 | -- Proxmox Support Team <support@proxmox.com> Thu, 08 Jan 2015 13:32:46 +0100 | |
2649 | ||
5a4cd260 DM |
2650 | qemu-server (3.3-7) unstable; urgency=low |
2651 | ||
2652 | * vzdump: use qga freeze in vzdump in snapshot mode | |
2653 | ||
2654 | * add custom numa topology support | |
2655 | ||
2656 | -- Proxmox Support Team <support@proxmox.com> Mon, 22 Dec 2014 17:24:24 +0100 | |
2657 | ||
260075e2 DM |
2658 | qemu-server (3.3-6) unstable; urgency=low |
2659 | ||
2660 | * API change: snapshot_create - remove unused freezefs flag. | |
2661 | ||
2662 | * snapshot_create: call fsfreeze if agent flag is set | |
2663 | ||
2664 | * qmpclient: use guest-sync-delimited | |
2665 | ||
2666 | -- Proxmox Support Team <support@proxmox.com> Thu, 04 Dec 2014 12:34:50 +0100 | |
2667 | ||
c2b9bbf3 DM |
2668 | qemu-server (3.3-5) unstable; urgency=low |
2669 | ||
2670 | * drive-mirror: cleanups, avoid division by zero bug | |
2671 | ||
2672 | * shutdown by Qemu Guest Agent if the agent flag is set | |
2673 | ||
2674 | * savevm-end : wait that savevm is finished | |
2675 | ||
2676 | -- Proxmox Support Team <support@proxmox.com> Mon, 01 Dec 2014 09:31:17 +0100 | |
2677 | ||
2678 | qemu-server (3.3-4) unstable; urgency=low | |
2679 | ||
2680 | * serial: allow to pass arbitrary device names | |
2681 | ||
2682 | * Add check if host has enough real CPUs for starting VM | |
2683 | ||
2684 | -- Proxmox Support Team <support@proxmox.com> Mon, 24 Nov 2014 07:42:10 +0100 | |
2685 | ||
ad2cb411 DM |
2686 | qemu-server (3.3-3) unstable; urgency=low |
2687 | ||
2688 | * drive-mirror: further improvments | |
2689 | ||
2690 | -- Proxmox Support Team <support@proxmox.com> Mon, 10 Nov 2014 06:32:04 +0100 | |
2691 | ||
2b8245f1 DM |
2692 | qemu-server (3.3-2) unstable; urgency=low |
2693 | ||
ad2cb411 | 2694 | * drive-mirror: wait that busy eq false before block-job-complete |
2b8245f1 DM |
2695 | |
2696 | -- Proxmox Support Team <support@proxmox.com> Fri, 07 Nov 2014 15:35:55 +0100 | |
2697 | ||
b9719d15 DM |
2698 | qemu-server (3.3-1) unstable; urgency=low |
2699 | ||
2700 | * enable write zeroes optimisations | |
2701 | ||
2702 | -- Proxmox Support Team <support@proxmox.com> Mon, 13 Oct 2014 10:35:49 +0200 | |
2703 | ||
88e9d6bc DM |
2704 | qemu-server (3.1-35) unstable; urgency=low |
2705 | ||
2706 | * fix bug #542: return VMID as integer | |
2707 | ||
2708 | -- Proxmox Support Team <support@proxmox.com> Wed, 17 Sep 2014 15:52:34 +0200 | |
2709 | ||
40e13560 DM |
2710 | qemu-server (3.1-34) unstable; urgency=low |
2711 | ||
2712 | * hotplug: allow scsi and virtio-scsi disk hotplug|unplug | |
2713 | ||
2714 | -- Proxmox Support Team <support@proxmox.com> Mon, 01 Sep 2014 11:35:49 +0200 | |
2715 | ||
d3f15aa9 DM |
2716 | qemu-server (3.1-33) unstable; urgency=low |
2717 | ||
2718 | * clone_vm: auto generate new uuid | |
2719 | ||
2720 | -- Proxmox Support Team <support@proxmox.com> Tue, 26 Aug 2014 09:23:58 +0200 | |
2721 | ||
56d12660 DM |
2722 | qemu-server (3.1-32) unstable; urgency=low |
2723 | ||
2724 | * add Broadwell cpu model | |
2725 | ||
2726 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Aug 2014 12:21:08 +0200 | |
2727 | ||
ad037bce DM |
2728 | qemu-server (3.1-31) unstable; urgency=low |
2729 | ||
2730 | * fix bug 529: fix virtio-serial when using q35 machines | |
2731 | ||
2732 | -- Proxmox Support Team <support@proxmox.com> Wed, 13 Aug 2014 06:17:08 +0200 | |
2733 | ||
f73de169 DM |
2734 | qemu-server (3.1-30) unstable; urgency=low |
2735 | ||
2736 | * bump max hostpci to 4 | |
2737 | ||
2738 | * set vga=none if x-vga passthrough is enabled | |
2739 | ||
2740 | -- Proxmox Support Team <support@proxmox.com> Wed, 06 Aug 2014 09:41:36 +0200 | |
2741 | ||
c4722d96 DM |
2742 | qemu-server (3.1-29) unstable; urgency=low |
2743 | ||
2744 | * vm_stop: do not use ha commands if $migratedfrom is set | |
2745 | ||
2746 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Jul 2014 06:53:05 +0200 | |
2747 | ||
0a2da90b DM |
2748 | qemu-server (3.1-28) unstable; urgency=low |
2749 | ||
2750 | * disable kvm cpu signature if x-vga is enabled | |
2751 | ||
2752 | -- Proxmox Support Team <support@proxmox.com> Thu, 24 Jul 2014 06:52:25 +0200 | |
2753 | ||
42d9f10b DM |
2754 | qemu-server (3.1-27) unstable; urgency=low |
2755 | ||
2756 | * pci passthrough: Reset device only if has_fl_reset is defined | |
2757 | ||
2758 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 Jul 2014 06:11:49 +0200 | |
2759 | ||
cba2311f DM |
2760 | qemu-server (3.1-26) unstable; urgency=low |
2761 | ||
2762 | * enable linked clones from snapshots (ceph) | |
2763 | ||
2764 | -- Proxmox Support Team <support@proxmox.com> Thu, 17 Jul 2014 09:28:47 +0200 | |
2765 | ||
c0298a21 DM |
2766 | qemu-server (3.1-25) unstable; urgency=low |
2767 | ||
2768 | * allow resize of virtio windows boot disk (virtio-win-0.1-74 have | |
2769 | fixed the resize bug) | |
2770 | ||
2771 | -- Proxmox Support Team <support@proxmox.com> Wed, 16 Jul 2014 12:48:03 +0200 | |
2772 | ||
fbbb287f DM |
2773 | qemu-server (3.1-24) unstable; urgency=low |
2774 | ||
2775 | * new option smbios1: specify SMBIOS type 1 fields (uuid, ...) | |
2776 | ||
2777 | -- Proxmox Support Team <support@proxmox.com> Thu, 26 Jun 2014 11:13:27 +0200 | |
2778 | ||
a29f4109 DM |
2779 | qemu-server (3.1-23) unstable; urgency=low |
2780 | ||
2781 | * vncproxy: remove check if VM is running | |
2782 | ||
2783 | -- Proxmox Support Team <support@proxmox.com> Wed, 25 Jun 2014 09:56:02 +0200 | |
2784 | ||
57a5429d DM |
2785 | qemu-server (3.1-22) unstable; urgency=low |
2786 | ||
2787 | * hostpci: add pci multifunction support | |
2788 | ||
2789 | * hostpci: add pcie and x-vga passthrough | |
2790 | ||
2791 | -- Proxmox Support Team <support@proxmox.com> Wed, 25 Jun 2014 09:31:30 +0200 | |
2792 | ||
6e0d60e4 DM |
2793 | qemu-server (3.1-21) unstable; urgency=low |
2794 | ||
2795 | * protect websocket API with vncticket | |
2796 | ||
2797 | -- Proxmox Support Team <support@proxmox.com> Tue, 24 Jun 2014 17:43:25 +0200 | |
2798 | ||
86888ff3 DM |
2799 | qemu-server (3.1-20) unstable; urgency=low |
2800 | ||
2801 | * vncwebsocket: do not proxy connection (not required) | |
2802 | ||
2803 | -- Proxmox Support Team <support@proxmox.com> Wed, 18 Jun 2014 12:45:39 +0200 | |
2804 | ||
d7b10d88 DM |
2805 | qemu-server (3.1-19) unstable; urgency=low |
2806 | ||
2807 | * do not depend on novnc-pve package (use new HTTPServer feature instead) | |
2808 | ||
2809 | -- Proxmox Support Team <support@proxmox.com> Wed, 18 Jun 2014 11:04:48 +0200 | |
2810 | ||
6d33c863 DM |
2811 | qemu-server (3.1-18) unstable; urgency=low |
2812 | ||
2813 | * depend on novnc-pve package | |
2814 | ||
2815 | * support webockets for VNC console | |
2816 | ||
2817 | * migration : add setup state | |
2818 | ||
2819 | * add virtio-net multiqueue support | |
2820 | ||
2821 | * add firewall option to qemu network interface | |
2822 | ||
2823 | * add initiator-name to iscsi drives if configured | |
2824 | ||
2825 | -- Proxmox Support Team <support@proxmox.com> Tue, 17 Jun 2014 09:00:03 +0200 | |
2826 | ||
cb33e6d6 DM |
2827 | qemu-server (3.1-17) unstable; urgency=low |
2828 | ||
2829 | * depend on pve-firewall package | |
2830 | ||
2831 | -- Proxmox Support Team <support@proxmox.com> Tue, 06 May 2014 11:28:26 +0200 | |
2832 | ||
2d82ca79 DM |
2833 | qemu-server (3.1-16) unstable; urgency=low |
2834 | ||
2835 | * fix bug #502: allow creation of empty vma archives | |
19d13324 DM |
2836 | |
2837 | * fix bug #510: move_disk - don't delete disk if used in a previous snasphot | |
2d82ca79 | 2838 | |
3cf90d7a DM |
2839 | * qmrestore: removed short timeout |
2840 | ||
19d13324 | 2841 | -- Proxmox Support Team <support@proxmox.com> Thu, 17 Apr 2014 09:29:26 +0200 |
2d82ca79 | 2842 | |
996562cf DM |
2843 | qemu-server (3.1-15) unstable; urgency=low |
2844 | ||
2845 | * correctly disable unwanted migrate features (xbzrle). | |
6c33685c DM |
2846 | |
2847 | * QemuMigrate: print migration xbzrle if enabled | |
996562cf DM |
2848 | |
2849 | -- Proxmox Support Team <support@proxmox.com> Mon, 10 Feb 2014 08:06:29 +0100 | |
2850 | ||
e3299e8b | 2851 | qemu-server (3.1-14) unstable; urgency=low |
8f14416d DM |
2852 | |
2853 | * Add title of VM to Spice Client | |
e3299e8b DM |
2854 | |
2855 | * deactivate volume after move_disk | |
2856 | ||
2857 | * add cpu_hotplug (and maxcpus config) | |
2858 | ||
2859 | * migration : enable auto-converge capability | |
2860 | ||
2861 | -- Proxmox Support Team <support@proxmox.com> Wed, 29 Jan 2014 06:49:16 +0100 | |
2862 | ||
4623ea34 DM |
2863 | qemu-server (3.1-13) unstable; urgency=low |
2864 | ||
2865 | * pci passthrough: new option to disable device ROM (rombar=off) | |
2866 | ||
2867 | -- Proxmox Support Team <support@proxmox.com> Fri, 13 Dec 2013 11:45:46 +0100 | |
2868 | ||
a96900bc DM |
2869 | qemu-server (3.1-12) unstable; urgency=low |
2870 | ||
2871 | * spiceproxy: use POST instead of GET | |
2872 | ||
2873 | -- Proxmox Support Team <support@proxmox.com> Tue, 10 Dec 2013 10:49:30 +0100 | |
2874 | ||
0ee6e547 DM |
2875 | qemu-server (3.1-11) unstable; urgency=low |
2876 | ||
2877 | * depend on pve-qemu-kvm >= 1.7-1 | |
213ef632 DM |
2878 | |
2879 | * fix 'qm unlink' command syntax | |
87c5bc34 DM |
2880 | |
2881 | * add 'pvscsi' to the list of scsi controllers (emulate the VMware | |
2882 | PVSCSI device) | |
0ee6e547 | 2883 | |
5b952ff5 DM |
2884 | * add 'lsi53c810' to the list of scsi controllers (supported on some |
2885 | very old Windows NT versions) | |
2886 | ||
e4c6e0b8 DM |
2887 | * add 'vmxnet3' to the list of available network card models (emulate |
2888 | VMware paravirtualized network card) | |
8d87f8aa DM |
2889 | |
2890 | * add drive option 'discard' | |
787dec6e DM |
2891 | |
2892 | * add support for new qemu throttling burst max parameters. | |
e4c6e0b8 | 2893 | |
0ee6e547 DM |
2894 | -- Proxmox Support Team <support@proxmox.com> Tue, 03 Dec 2013 10:48:33 +0100 |
2895 | ||
1855c1c0 DM |
2896 | qemu-server (3.1-10) unstable; urgency=low |
2897 | ||
2898 | * add +lahf_lm flag to kvm64 cpudef | |
2899 | ||
2900 | -- Proxmox Support Team <support@proxmox.com> Fri, 29 Nov 2013 09:18:39 +0100 | |
56e8b634 | 2901 | |
1855c1c0 DM |
2902 | qemu-server (3.1-9) unstable; urgency=low |
2903 | ||
56e8b634 DM |
2904 | * clone: deactivate volumes after clone to other node |
2905 | ||
2906 | -- Proxmox Support Team <support@proxmox.com> Tue, 19 Nov 2013 08:17:35 +0100 | |
2907 | ||
d0d31281 DM |
2908 | qemu-server (3.1-8) unstable; urgency=low |
2909 | ||
2910 | * clone: correctly check drive options (avoid feature is not available bug) | |
2911 | ||
2912 | -- Proxmox Support Team <support@proxmox.com> Mon, 14 Oct 2013 07:36:26 +0200 | |
2913 | ||
5c5cc372 DM |
2914 | qemu-server (3.1-7) unstable; urgency=low |
2915 | ||
2916 | * spice: add multi-monitors support | |
2917 | ||
2918 | -- Proxmox Support Team <support@proxmox.com> Wed, 02 Oct 2013 09:13:23 +0200 | |
2919 | ||
b72e2e92 DM |
2920 | qemu-server (3.1-6) unstable; urgency=low |
2921 | ||
2922 | * use new PVE::Storage::abs_filesystem_path() | |
990fc5e2 DM |
2923 | |
2924 | * use warnings instead of global -w flag | |
b72e2e92 DM |
2925 | |
2926 | -- Proxmox Support Team <support@proxmox.com> Tue, 01 Oct 2013 12:42:42 +0200 | |
2927 | ||
92e3e2da DM |
2928 | qemu-server (3.1-5) unstable; urgency=low |
2929 | ||
2930 | * introduce new ostype 'solaris' (run without x2apic). | |
2931 | ||
2932 | -- Proxmox Support Team <support@proxmox.com> Tue, 24 Sep 2013 06:55:33 +0200 | |
2933 | ||
7e3c14fa DM |
2934 | qemu-server (3.1-4) unstable; urgency=low |
2935 | ||
2936 | * qemu migrate : only wait for spice server online + eval | |
2937 | ||
2938 | -- Proxmox Support Team <support@proxmox.com> Thu, 19 Sep 2013 06:29:39 +0200 | |
2939 | ||
4e8fd400 DM |
2940 | qemu-server (3.1-3) unstable; urgency=low |
2941 | ||
2942 | * speedup restore on glusterfs (do not write zero bytes) | |
2943 | ||
2944 | -- Proxmox Support Team <support@proxmox.com> Tue, 17 Sep 2013 09:13:34 +0200 | |
2945 | ||
755828cc DM |
2946 | qemu-server (3.1-2) unstable; urgency=low |
2947 | ||
2948 | * Allow VMAdmin/DatastoreUser to delete disk | |
2949 | ||
2950 | -- Proxmox Support Team <support@proxmox.com> Thu, 05 Sep 2013 07:48:07 +0200 | |
2951 | ||
ecf49168 DM |
2952 | qemu-server (3.1-1) unstable; urgency=low |
2953 | ||
2954 | * allow pass through of usb parallel devices (--parallel0 /dev/usb/lp0) | |
2955 | ||
2956 | -- Proxmox Support Team <support@proxmox.com> Wed, 14 Aug 2013 12:20:23 +0200 | |
2957 | ||
3fd9a163 DM |
2958 | qemu-server (3.0-30) unstable; urgency=low |
2959 | ||
2960 | * fix bugs in migration code (wrong qw() usage) | |
2961 | ||
2962 | -- Proxmox Support Team <support@proxmox.com> Mon, 12 Aug 2013 09:49:20 +0200 | |
2963 | ||
7dbff9d2 DM |
2964 | qemu-server (3.0-29) unstable; urgency=low |
2965 | ||
2966 | * vncproxy: load config from correct node | |
2967 | ||
2968 | -- Proxmox Support Team <support@proxmox.com> Tue, 06 Aug 2013 08:15:59 +0200 | |
2969 | ||
d39020e5 DM |
2970 | qemu-server (3.0-28) unstable; urgency=low |
2971 | ||
2972 | * allow to use a socket for serial devices | |
2973 | ||
2974 | * implement 'qm terminal' to open terminal via serial device | |
2975 | ||
2976 | * add ability to run without graphic card ('vga: serial[n]') | |
2977 | ||
2978 | -- Proxmox Support Team <support@proxmox.com> Fri, 02 Aug 2013 10:05:35 +0200 | |
2979 | ||
cf48d634 DM |
2980 | qemu-server (3.0-27) unstable; urgency=low |
2981 | ||
2982 | * add support for unsecure/fast migration (setting in datacenter.cfg) | |
2983 | ||
2984 | -- Proxmox Support Team <support@proxmox.com> Fri, 26 Jul 2013 11:24:36 +0200 | |
2985 | ||
26d63c8c DM |
2986 | qemu-server (3.0-26) unstable; urgency=low |
2987 | ||
2988 | * remove spice cert paths (depend on pve-qemu-kvm >= 1.4-16) | |
7c14dcae DM |
2989 | |
2990 | * implement spice seamless migration | |
26d63c8c DM |
2991 | |
2992 | -- Proxmox Support Team <support@proxmox.com> Tue, 23 Jul 2013 10:08:33 +0200 | |
2993 | ||
eba883be DM |
2994 | qemu-server (3.0-25) unstable; urgency=low |
2995 | ||
2996 | * support usb redirection devices for spice (usb[n]: spice) | |
5acbfe9e DM |
2997 | |
2998 | * disable tablet device by default for spice | |
eba883be DM |
2999 | |
3000 | -- Proxmox Support Team <support@proxmox.com> Fri, 19 Jul 2013 09:38:25 +0200 | |
3001 | ||
bcf1b404 DM |
3002 | qemu-server (3.0-24) unstable; urgency=low |
3003 | ||
3004 | * spiceproxy API: allow client to choose proxy address | |
3005 | ||
3006 | * spiceproxy API: read cert subject name directly using Net::SSLeay | |
3007 | ||
3008 | * spice: use TLS (encrypt whole traffic) | |
3009 | ||
3010 | -- Proxmox Support Team <support@proxmox.com> Thu, 18 Jul 2013 08:14:46 +0200 | |
3011 | ||
82a87eb4 DM |
3012 | qemu-server (3.0-23) unstable; urgency=low |
3013 | ||
3014 | * allow to pass SCSI generic devices to guests, for example "scsi0: /dev/sg5" | |
3015 | ||
3016 | -- Proxmox Support Team <support@proxmox.com> Tue, 16 Jul 2013 06:49:45 +0200 | |
3017 | ||
be190583 DM |
3018 | qemu-server (3.0-22) unstable; urgency=low |
3019 | ||
3020 | * cpu flags optimization | |
3021 | ||
3022 | -- Proxmox Support Team <support@proxmox.com> Mon, 15 Jul 2013 09:14:49 +0200 | |
3023 | ||
013d8cac DM |
3024 | qemu-server (3.0-21) unstable; urgency=low |
3025 | ||
3026 | * add support for SPICE | |
3027 | ||
3028 | -- Proxmox Support Team <support@proxmox.com> Wed, 26 Jun 2013 13:15:48 +0200 | |
3029 | ||
89b0baa6 DM |
3030 | qemu-server (3.0-20) unstable; urgency=low |
3031 | ||
3032 | * new API to update VM config: this one is fully asynchronous. | |
3033 | ||
3034 | * snapshot rollback: use pc-i440fx-1.4 as default | |
3035 | ||
3036 | -- Proxmox Support Team <support@proxmox.com> Fri, 07 Jun 2013 11:44:16 +0200 | |
3037 | ||
bf6d72aa DM |
3038 | qemu-server (3.0-19) unstable; urgency=low |
3039 | ||
3040 | * config: implement new 'machine' configuration | |
3041 | ||
3042 | * migrate: pass --machine parameter to remote 'qm start' command | |
3043 | ||
3044 | * snapshot: store/use 'machine' confifiguration | |
3045 | ||
3046 | -- Proxmox Support Team <support@proxmox.com> Wed, 05 Jun 2013 10:27:47 +0200 | |
3047 | ||
37eccdb5 DM |
3048 | qemu-server (3.0-18) unstable; urgency=low |
3049 | ||
3050 | * imlement delete flag for move_disk | |
3051 | ||
3052 | * API: rename move to move_disk | |
3053 | ||
3054 | -- Proxmox Support Team <support@proxmox.com> Fri, 31 May 2013 10:57:50 +0200 | |
3055 | ||
7baa079c DM |
3056 | qemu-server (3.0-17) unstable; urgency=low |
3057 | ||
3058 | * implement storage migration ("qm move") | |
3059 | ||
3060 | -- Proxmox Support Team <support@proxmox.com> Wed, 29 May 2013 13:01:16 +0200 | |
3061 | ||
a8c7e31e DM |
3062 | qemu-server (3.0-16) unstable; urgency=low |
3063 | ||
3064 | * fix bug 395: correctly handle unused disk with storage alias | |
3065 | ||
3066 | * fix unused disk handling (do not hide unused disks when used with snapshot). | |
3067 | ||
3068 | -- Proxmox Support Team <support@proxmox.com> Tue, 28 May 2013 12:23:12 +0200 | |
3069 | ||
13471a97 DM |
3070 | qemu-server (3.0-15) unstable; urgency=low |
3071 | ||
3072 | * qemu_img_format : use raw for as default for other storage | |
3073 | ||
3074 | -- Proxmox Support Team <support@proxmox.com> Thu, 23 May 2013 11:33:47 +0200 | |
3075 | ||
12c6aafb DM |
3076 | qemu-server (3.0-14) unstable; urgency=low |
3077 | ||
3078 | * fix bug #389: avoid error if balloon is undefined | |
3079 | ||
3080 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 May 2013 07:17:38 +0200 | |
3081 | ||
a3dbf3b9 DM |
3082 | qemu-server (3.0-13) unstable; urgency=low |
3083 | ||
3084 | * fix bug #391 - restore: test if requested format is supported | |
3085 | ||
3086 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 May 2013 12:03:56 +0200 | |
3087 | ||
4f2df3ba DM |
3088 | qemu-server (3.0-12) unstable; urgency=low |
3089 | ||
3090 | * use add_vm_to_pool/remove_vm_from_pool from PVE::AccessControl | |
3091 | ||
3092 | -- Proxmox Support Team <support@proxmox.com> Tue, 14 May 2013 12:02:41 +0200 | |
3093 | ||
c89dcd85 DM |
3094 | qemu-server (3.0-11) unstable; urgency=low |
3095 | ||
3096 | * clone disk : keep source volume params | |
3097 | ||
3098 | -- Proxmox Support Team <support@proxmox.com> Tue, 14 May 2013 10:18:21 +0200 | |
3099 | ||
3cf54458 DM |
3100 | qemu-server (3.0-10) unstable; urgency=low |
3101 | ||
3102 | * fix bug #381: use PVE::Tools::next_migrate_port() | |
4a5a2590 DM |
3103 | |
3104 | * clone: check is we can clone to target storage | |
3cf54458 DM |
3105 | |
3106 | -- Proxmox Support Team <support@proxmox.com> Mon, 13 May 2013 07:31:47 +0200 | |
3107 | ||
046e4104 DM |
3108 | qemu-server (3.0-9) unstable; urgency=low |
3109 | ||
3110 | * restore: do not restore template flag | |
3111 | ||
3112 | -- Proxmox Support Team <support@proxmox.com> Wed, 08 May 2013 10:23:49 +0200 | |
3113 | ||
ccfb9ffe DM |
3114 | qemu-server (3.0-8) unstable; urgency=low |
3115 | ||
3116 | * qemu_img_format: use 'raw' for lvm | |
3117 | ||
3118 | * drive-mirror : die if stats are empty | |
3119 | ||
3120 | * set long timeout for query-block-jobs | |
3121 | ||
3122 | -- Proxmox Support Team <support@proxmox.com> Tue, 07 May 2013 10:19:19 +0200 | |
3123 | ||
10cbe3d4 DM |
3124 | qemu-server (3.0-7) unstable; urgency=low |
3125 | ||
3126 | * has_feature: return list of allowed nodes | |
3127 | ||
3128 | -- Proxmox Support Team <support@proxmox.com> Mon, 06 May 2013 08:58:35 +0200 | |
3129 | ||
90995a78 DM |
3130 | qemu-server (3.0-6) unstable; urgency=low |
3131 | ||
3132 | * fix bug #379 - restore: allow to overwrite existing VMs if user has | |
3133 | VM.Backup permissions | |
3134 | ||
3135 | -- Proxmox Support Team <support@proxmox.com> Fri, 03 May 2013 07:53:40 +0200 | |
3136 | ||
6116f729 DM |
3137 | qemu-server (3.0-5) unstable; urgency=low |
3138 | ||
3139 | * implement shared file locks | |
3140 | ||
3141 | -- Proxmox Support Team <support@proxmox.com> Thu, 25 Apr 2013 11:35:01 +0200 | |
3142 | ||
6fa741fc DM |
3143 | qemu-server (3.0-4) unstable; urgency=low |
3144 | ||
3145 | * fix bug 377: make qm rescan work properly | |
3146 | ||
3147 | * avoid endless loop in QMPClient | |
3148 | ||
3149 | * use vm create permissions for templates | |
3150 | ||
3151 | -- Proxmox Support Team <support@proxmox.com> Wed, 24 Apr 2013 07:59:28 +0200 | |
3152 | ||
194d171e DM |
3153 | qemu-server (3.0-3) unstable; urgency=low |
3154 | ||
3155 | * allow sparse restore for sheepdog and rbd | |
3156 | ||
3157 | -- Proxmox Support Team <support@proxmox.com> Thu, 18 Apr 2013 06:21:40 +0200 | |
3158 | ||
e061bcce DM |
3159 | qemu-server (3.0-2) unstable; urgency=low |
3160 | ||
3161 | * fix warnings in syslog | |
3162 | ||
3163 | -- Proxmox Support Team <support@proxmox.com> Fri, 22 Mar 2013 06:25:12 +0100 | |
3164 | ||
1849bae6 DM |
3165 | qemu-server (3.0-1) unstable; urgency=low |
3166 | ||
3167 | * start 3.0 development | |
3168 | ||
3169 | -- Proxmox Support Team <support@proxmox.com> Tue, 05 Mar 2013 11:39:08 +0100 | |
3170 | ||
fc97ae27 DM |
3171 | qemu-server (2.3-17) unstable; urgency=low |
3172 | ||
3173 | * fix backup-cancel timeout | |
3174 | ||
3175 | -- Proxmox Support Team <support@proxmox.com> Fri, 01 Mar 2013 10:58:58 +0100 | |
3176 | ||
cff3c02e DM |
3177 | qemu-server (2.3-16) unstable; urgency=low |
3178 | ||
3179 | * vncproxy (another try): wait max 10s for the socket if it does not | |
3180 | exist | |
3181 | ||
3182 | -- Proxmox Support Team <support@proxmox.com> Fri, 01 Mar 2013 06:42:36 +0100 | |
3183 | ||
8da4165a DM |
3184 | qemu-server (2.3-15) unstable; urgency=low |
3185 | ||
3186 | * revert vncproxy change because it breaks console on remote hosts. | |
3187 | ||
3188 | -- Proxmox Support Team <support@proxmox.com> Thu, 28 Feb 2013 12:53:59 +0100 | |
3189 | ||
6fe20558 DM |
3190 | qemu-server (2.3-14) unstable; urgency=low |
3191 | ||
3192 | * bugfix #340 : don't set cache=none to cdrom | |
b7b1ac9d DM |
3193 | |
3194 | * Migrate: fix check if a backing file exist | |
64b05128 DM |
3195 | |
3196 | * vncproxy: wait max 10s for the socket if it does not exist | |
60635a57 DM |
3197 | |
3198 | * vzdump: improve error reporting | |
6fe20558 DM |
3199 | |
3200 | -- Proxmox Support Team <support@proxmox.com> Thu, 28 Feb 2013 06:21:30 +0100 | |
3201 | ||
ffdf91ba DM |
3202 | qemu-server (2.3-13) unstable; urgency=low |
3203 | ||
3204 | * set cache=none by default | |
3205 | ||
3206 | -- Proxmox Support Team <support@proxmox.com> Mon, 25 Feb 2013 06:12:14 +0100 | |
3207 | ||
2dbe827e DM |
3208 | qemu-server (2.3-12) unstable; urgency=low |
3209 | ||
3210 | * disable hotplug by default (revert previous change) | |
064bfb36 DM |
3211 | |
3212 | * disable usb2 controller by default (revert previous change) | |
2dbe827e DM |
3213 | |
3214 | -- Proxmox Support Team <support@proxmox.com> Fri, 22 Feb 2013 09:52:13 +0100 | |
3215 | ||
1575bfcc DM |
3216 | qemu-server (2.3-11) unstable; urgency=low |
3217 | ||
3218 | * fix backup parameters for pve-qemu-kvm 1.4-4 | |
3219 | ||
3220 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Feb 2013 10:47:55 +0100 | |
3221 | ||
f1c8f1d7 DM |
3222 | qemu-server (2.3-10) unstable; urgency=low |
3223 | ||
3224 | * enable hotplug by default | |
3225 | ||
3226 | * enable usb2 controller by default | |
3227 | ||
3228 | -- Proxmox Support Team <support@proxmox.com> Tue, 19 Feb 2013 10:45:28 +0100 | |
3229 | ||
51ccb37a DM |
3230 | qemu-server (2.3-9) unstable; urgency=low |
3231 | ||
3232 | * depend on pve-qemu-kvm >= 1.4-1 | |
3233 | ||
3234 | * qemu 1.4 fix : rename stats-polling-interval to | |
3235 | guest-stats-polling-interval | |
0302101c | 3236 | |
ef1c835d DM |
3237 | * remove expected_downtime from migration status (not set in qemu 1.4, |
3238 | always 0) | |
51ccb37a | 3239 | |
ef1c835d DM |
3240 | * do not set cache=none for .raw files - use qemu default instead |
3241 | (writeback) | |
3242 | ||
51ccb37a DM |
3243 | -- Proxmox Support Team <support@proxmox.com> Wed, 13 Feb 2013 10:38:13 +0100 |
3244 | ||
ebb55558 DM |
3245 | qemu-server (2.3-8) unstable; urgency=low |
3246 | ||
3247 | * fix tar restore: correctly check if VM config already exists | |
3248 | ||
3249 | -- Proxmox Support Team <support@proxmox.com> Mon, 28 Jan 2013 09:53:12 +0100 | |
3250 | ||
051347aa DM |
3251 | qemu-server (2.3-7) unstable; urgency=low |
3252 | ||
3253 | * allow to suspend/resume VM during backup | |
3254 | ||
3255 | -- Proxmox Support Team <support@proxmox.com> Thu, 17 Jan 2013 10:25:17 +0100 | |
3256 | ||
19599cd9 DM |
3257 | qemu-server (2.3-6) unstable; urgency=low |
3258 | ||
3259 | * fix bug #315: cancel backup before stopping the VM | |
3260 | ||
3261 | -- Proxmox Support Team <support@proxmox.com> Wed, 16 Jan 2013 13:22:58 +0100 | |
3262 | ||
907ea891 DM |
3263 | qemu-server (2.3-5) unstable; urgency=low |
3264 | ||
3265 | * fix bug #307: correctly restore disk settings | |
3266 | ||
3267 | -- Proxmox Support Team <support@proxmox.com> Mon, 07 Jan 2013 06:48:48 +0100 | |
3268 | ||
27d51e24 DM |
3269 | qemu-server (2.3-4) unstable; urgency=low |
3270 | ||
3271 | * qmrestore vma files: when restoring to same VMID, only remove volumes | |
3272 | contained in backup - other volumes will be still available as | |
3273 | 'unused' disks. Note: tar restore still removes all volumes. | |
3274 | ||
3275 | -- Proxmox Support Team <support@proxmox.com> Fri, 04 Jan 2013 07:02:00 +0100 | |
3276 | ||
8e2100f9 DM |
3277 | qemu-server (2.3-3) unstable; urgency=low |
3278 | ||
3279 | * fix Bug #293: CDROM size not reset when set to use no media | |
3280 | ||
3281 | * set migrate_downtime default value to 0.1 (and use float instead of int) | |
3282 | ||
3283 | * implement dynamic migration_downtime | |
3284 | ||
3285 | * allow manual ballooning if shares is set to zero | |
3286 | ||
3287 | * new api2 call: vm_feature (test support for snapshots/clone feature) | |
3288 | ||
3289 | -- Proxmox Support Team <support@proxmox.com> Wed, 02 Jan 2013 06:31:38 +0100 | |
3290 | ||
64e7fcf2 DM |
3291 | qemu-server (2.3-2) unstable; urgency=low |
3292 | ||
3293 | * use memory info from ballon driver (if enabled) | |
3294 | ||
3295 | -- Proxmox Support Team <support@proxmox.com> Tue, 18 Dec 2012 12:51:57 +0100 | |
3296 | ||
91bd6c90 DM |
3297 | qemu-server (2.3-1) unstable; urgency=low |
3298 | ||
3299 | * include new qemu backup feature | |
3300 | ||
3301 | -- Proxmox Support Team <support@proxmox.com> Wed, 12 Dec 2012 15:14:59 +0100 | |
3302 | ||
dd06a74b DM |
3303 | qemu-server (2.0-71) unstable; urgency=low |
3304 | ||
3305 | * show better error message if bridge does not exist | |
3306 | ||
3307 | * QMPClient: support fdsets | |
3308 | ||
3309 | -- Proxmox Support Team <support@proxmox.com> Tue, 11 Dec 2012 11:17:47 +0100 | |
3310 | ||
fa7ae705 DM |
3311 | qemu-server (2.0-70) unstable; urgency=low |
3312 | ||
3313 | * fix version parser for qemu 1.3 | |
3314 | ||
98a0dc5e DM |
3315 | * add new cpu types: SandyBridge Haswell Opteron_G4 Opteron_G5 |
3316 | ||
3317 | * remove rhel specific cpu types: cpu64-rhel6 cpu64-rhel5 | |
3318 | ||
fa7ae705 DM |
3319 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Nov 2012 07:45:19 +0100 |
3320 | ||
42ca8953 DM |
3321 | qemu-server (2.0-69) unstable; urgency=low |
3322 | ||
3323 | * fix ballon monitor command (use bytes instead of MBs) | |
3324 | ||
3325 | -- Proxmox Support Team <support@proxmox.com> Fri, 16 Nov 2012 06:13:46 +0100 | |
3326 | ||
075b417a DM |
3327 | qemu-server (2.0-68) unstable; urgency=low |
3328 | ||
3329 | * vzdump: store drive in correct order (sort) to avoid confusion | |
3330 | ||
3331 | -- Proxmox Support Team <support@proxmox.com> Mon, 05 Nov 2012 06:25:33 +0100 | |
3332 | ||
445f06cd DM |
3333 | qemu-server (2.0-67) unstable; urgency=low |
3334 | ||
3335 | * fix allocation size in qmrestore | |
3336 | ||
3337 | -- Proxmox Support Team <support@proxmox.com> Sat, 03 Nov 2012 07:54:06 +0100 | |
3338 | ||
4dac70e5 DM |
3339 | qemu-server (2.0-66) unstable; urgency=low |
3340 | ||
3341 | * vzdump: restore sata drives correctly | |
3342 | ||
3343 | -- Proxmox Support Team <support@proxmox.com> Fri, 02 Nov 2012 07:43:16 +0100 | |
3344 | ||
c46eccbf DM |
3345 | qemu-server (2.0-65) unstable; urgency=low |
3346 | ||
3347 | * remove hardcoded blowfish cipher | |
3348 | ||
3349 | -- Proxmox Support Team <support@proxmox.com> Wed, 31 Oct 2012 13:58:27 +0100 | |
3350 | ||
b3ea07f7 DM |
3351 | qemu-server (2.0-64) unstable; urgency=low |
3352 | ||
3353 | * fix memory leak in QMP Client (many thanks to Stefan!) | |
3354 | ||
3355 | -- Proxmox Support Team <support@proxmox.com> Mon, 29 Oct 2012 12:14:51 +0100 | |
3356 | ||
c811a3c6 DM |
3357 | qemu-server (2.0-63) unstable; urgency=low |
3358 | ||
3359 | * fix bug in vmtar | |
3360 | ||
3361 | -- Proxmox Support Team <support@proxmox.com> Thu, 25 Oct 2012 10:00:50 +0200 | |
3362 | ||
3da85107 DM |
3363 | qemu-server (2.0-62) unstable; urgency=low |
3364 | ||
3365 | * vncproxy: wait until vnc port is ready | |
3366 | ||
3367 | -- Proxmox Support Team <support@proxmox.com> Wed, 24 Oct 2012 08:58:52 +0200 | |
3368 | ||
a70ebde3 DM |
3369 | qemu-server (2.0-61) unstable; urgency=low |
3370 | ||
3371 | * add 'win8' ostype (same defaults as win7 for now) | |
3372 | ||
3373 | -- Proxmox Support Team <support@proxmox.com> Tue, 23 Oct 2012 09:35:27 +0200 | |
3374 | ||
15a2e229 DM |
3375 | qemu-server (2.0-60) unstable; urgency=low |
3376 | ||
3377 | * fix bug 258: use bridge mtu for tap interfaces | |
3378 | ||
3379 | -- Proxmox Support Team <support@proxmox.com> Mon, 22 Oct 2012 12:26:42 +0200 | |
3380 | ||
585b6e28 DM |
3381 | qemu-server (2.0-59) unstable; urgency=low |
3382 | ||
3383 | * disable vzdump for VM containing snapshots | |
3384 | ||
3385 | -- Proxmox Support Team <support@proxmox.com> Thu, 27 Sep 2012 09:41:19 +0200 | |
3386 | ||
8c559505 DM |
3387 | qemu-server (2.0-58) unstable; urgency=low |
3388 | ||
3389 | * fix bug 251: use new command line syntax | |
3390 | ||
3391 | -- Proxmox Support Team <support@proxmox.com> Wed, 26 Sep 2012 12:43:17 +0200 | |
3392 | ||
037a9746 DM |
3393 | qemu-server (2.0-57) unstable; urgency=low |
3394 | ||
3395 | * fix migrating VMs with snapshots | |
3396 | ||
3397 | -- Proxmox Support Team <support@proxmox.com> Tue, 25 Sep 2012 08:12:37 +0200 | |
3398 | ||
d18723f9 DM |
3399 | qemu-server (2.0-56) unstable; urgency=low |
3400 | ||
3401 | * include shanpshot support | |
3402 | ||
3403 | -- Proxmox Support Team <support@proxmox.com> Mon, 24 Sep 2012 15:59:40 +0200 | |
3404 | ||
a5bae0f8 DM |
3405 | qemu-server (2.0-55) unstable; urgency=low |
3406 | ||
3407 | * migrate: disable xbzrle (not stable) | |
3408 | ||
3409 | -- Proxmox Support Team <support@proxmox.com> Fri, 31 Aug 2012 11:04:35 +0200 | |
3410 | ||
8cba2f63 DM |
3411 | qemu-server (2.0-54) unstable; urgency=low |
3412 | ||
3413 | * use mbps instead of bps | |
3414 | ||
3415 | * try to make migrate more stable | |
3416 | ||
3417 | -- Proxmox Support Team <support@proxmox.com> Thu, 30 Aug 2012 12:16:39 +0200 | |
3418 | ||
177e3523 DM |
3419 | qemu-server (2.0-53) unstable; urgency=low |
3420 | ||
cb0a8bc8 DM |
3421 | * livemigrate : activate xbzrle cache |
3422 | ||
3423 | * scsihw: add megasas controller | |
3424 | ||
3425 | * partly fix bug 247: retry qmp open | |
177e3523 DM |
3426 | |
3427 | -- Proxmox Support Team <support@proxmox.com> Mon, 27 Aug 2012 13:45:18 +0200 | |
3428 | ||
4723c174 DM |
3429 | qemu-server (2.0-52) unstable; urgency=low |
3430 | ||
3431 | * fix bug 217: stop VM after failed migrate | |
3432 | ||
3433 | -- Proxmox Support Team <support@proxmox.com> Thu, 23 Aug 2012 10:33:57 +0200 | |
3434 | ||
858f65fe DM |
3435 | qemu-server (2.0-51) unstable; urgency=low |
3436 | ||
3437 | * support up to 32 network devices | |
3438 | ||
3439 | * support up to 16 virtio devices | |
3440 | ||
3441 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Aug 2012 10:06:39 +0200 | |
3442 | ||
c21536ab DM |
3443 | qemu-server (2.0-50) unstable; urgency=low |
3444 | ||
3445 | * implement 'qm rescan' to update disk sizes and unused disk info | |
3446 | ||
3447 | -- Proxmox Support Team <support@proxmox.com> Mon, 20 Aug 2012 09:22:29 +0200 | |
3448 | ||
dab36e1e DM |
3449 | qemu-server (2.0-49) unstable; urgency=low |
3450 | ||
3451 | * fix bug 242: re-add old monitor code | |
3452 | ||
3453 | -- Proxmox Support Team <support@proxmox.com> Fri, 17 Aug 2012 10:33:37 +0200 | |
3454 | ||
3a97020c DM |
3455 | qemu-server (2.0-48) unstable; urgency=low |
3456 | ||
3457 | * add size hint to drive options | |
3458 | ||
3459 | * new 'qm resize' command | |
3460 | ||
3461 | -- Proxmox Support Team <support@proxmox.com> Tue, 14 Aug 2012 06:55:39 +0200 | |
3462 | ||
de733742 DM |
3463 | qemu-server (2.0-47) unstable; urgency=low |
3464 | ||
3465 | * implement virtio-scsi-pci controller | |
3466 | ||
3467 | -- Proxmox Support Team <support@proxmox.com> Wed, 01 Aug 2012 08:57:52 +0200 | |
3468 | ||
eabe0da0 DM |
3469 | qemu-server (2.0-46) unstable; urgency=low |
3470 | ||
3471 | * bug fix: allow to set devices directly (-ide1 /dev/XYZ) | |
3472 | ||
3473 | -- Proxmox Support Team <support@proxmox.com> Fri, 27 Jul 2012 11:59:14 +0200 | |
3474 | ||
373ea579 DM |
3475 | qemu-server (2.0-45) unstable; urgency=low |
3476 | ||
3477 | * migrate: only scan available storages | |
3478 | ||
3479 | -- Proxmox Support Team <support@proxmox.com> Mon, 16 Jul 2012 10:18:22 +0200 | |
3480 | ||
522c8f97 DM |
3481 | qemu-server (2.0-44) unstable; urgency=low |
3482 | ||
3483 | * migrate: only scan necessary storage for unused volumes | |
3484 | ||
3485 | -- Proxmox Support Team <support@proxmox.com> Mon, 16 Jul 2012 06:59:23 +0200 | |
3486 | ||
26f11676 DM |
3487 | qemu-server (2.0-43) unstable; urgency=low |
3488 | ||
3489 | * use new QMPClient code | |
3490 | ||
3491 | -- Proxmox Support Team <support@proxmox.com> Fri, 13 Jul 2012 07:05:28 +0200 | |
3492 | ||
4fc52424 DM |
3493 | qemu-server (2.0-42) unstable; urgency=low |
3494 | ||
3495 | * fix pool permission checks on create | |
3496 | ||
3497 | -- Proxmox Support Team <support@proxmox.com> Wed, 30 May 2012 10:13:11 +0200 | |
3498 | ||
f5bdefa4 DM |
3499 | qemu-server (2.0-41) unstable; urgency=low |
3500 | ||
3501 | * more fixes for newer pve-storage versions | |
3502 | ||
3503 | -- Proxmox Support Team <support@proxmox.com> Thu, 24 May 2012 07:24:00 +0200 | |
3504 | ||
a125592c DM |
3505 | qemu-server (2.0-40) unstable; urgency=low |
3506 | ||
3507 | * minor fixes for newer pve-storage versions | |
3508 | ||
3509 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 May 2012 07:23:31 +0200 | |
3510 | ||
59411c4e DM |
3511 | qemu-server (2.0-39) unstable; urgency=low |
3512 | ||
3513 | * new startup option to define startup order. | |
41e7bdb9 DM |
3514 | |
3515 | * do not start VMs with /etc/init.d/qemu-server. This is now | |
3516 | done with /etc/init.d/pve-manager | |
3517 | ||
3518 | * qm: removed startall/stopall commands | |
59411c4e DM |
3519 | |
3520 | -- Proxmox Support Team <support@proxmox.com> Thu, 19 Apr 2012 14:26:04 +0200 | |
3521 | ||
084d6a59 DM |
3522 | qemu-server (2.0-38) unstable; urgency=low |
3523 | ||
3524 | * add directsync cache mode | |
71c11a83 DM |
3525 | |
3526 | * fix bug #147: allow to set migrate_downtime to 0 | |
084d6a59 DM |
3527 | |
3528 | -- Proxmox Support Team <support@proxmox.com> Wed, 11 Apr 2012 08:51:56 +0200 | |
3529 | ||
22d646a7 DM |
3530 | qemu-server (2.0-37) unstable; urgency=low |
3531 | ||
3532 | * fix bug in storage availability check (migrate) | |
3533 | ||
3534 | -- Proxmox Support Team <support@proxmox.com> Sat, 07 Apr 2012 08:25:59 +0200 | |
3535 | ||
b7e0c8bf DM |
3536 | qemu-server (2.0-36) unstable; urgency=low |
3537 | ||
3538 | * use '-no-kvm-pit-reinjection -no-hpet' for win7 and w2k8 guests. | |
3539 | ||
3540 | -- Proxmox Support Team <support@proxmox.com> Thu, 05 Apr 2012 12:34:00 +0200 | |
3541 | ||
d7810bc1 DM |
3542 | qemu-server (2.0-35) unstable; urgency=low |
3543 | ||
3544 | * fix bug #134: allow to pass file names to qmrestore and 'qm set' | |
3545 | ||
3546 | -- Proxmox Support Team <support@proxmox.com> Mon, 02 Apr 2012 10:51:41 +0200 | |
3547 | ||
47152e2e DM |
3548 | qemu-server (2.0-34) unstable; urgency=low |
3549 | ||
3550 | * fix bug #12: check storage availability early (migrate) | |
3551 | ||
3552 | -- Proxmox Support Team <support@proxmox.com> Fri, 30 Mar 2012 09:12:46 +0200 | |
3553 | ||
8b192abf DM |
3554 | qemu-server (2.0-33) unstable; urgency=low |
3555 | ||
3556 | * fix bug #121: activate volumes correctly | |
3557 | ||
3558 | -- Proxmox Support Team <support@proxmox.com> Thu, 29 Mar 2012 11:09:36 +0200 | |
3559 | ||
036e0e2b DM |
3560 | qemu-server (2.0-32) unstable; urgency=low |
3561 | ||
3562 | * fix usb host syntax (correctly pass hexadecimal numbers with prefix | |
3563 | '0x' to kvm) | |
3564 | ||
3565 | * document rerror/werror options | |
3566 | ||
3567 | -- Proxmox Support Team <support@proxmox.com> Thu, 29 Mar 2012 07:11:51 +0200 | |
3568 | ||
9f03d50d DM |
3569 | qemu-server (2.0-31) unstable; urgency=low |
3570 | ||
3571 | * use new network setup code from PVE::Network (libpve-common-perl) | |
3572 | ||
3573 | -- Proxmox Support Team <support@proxmox.com> Wed, 28 Mar 2012 10:39:12 +0200 | |
3574 | ||
cce37749 DM |
3575 | qemu-server (2.0-30) unstable; urgency=low |
3576 | ||
3577 | * fix ha migration | |
3578 | ||
3579 | -- Proxmox Support Team <support@proxmox.com> Tue, 27 Mar 2012 12:20:33 +0200 | |
3580 | ||
88fc87b4 DM |
3581 | qemu-server (2.0-29) unstable; urgency=low |
3582 | ||
3583 | * fix bug #97: execute 'clusvcadm' commands for HA managed VMs | |
3584 | ||
3585 | -- Proxmox Support Team <support@proxmox.com> Tue, 27 Mar 2012 10:36:23 +0200 | |
3586 | ||
fc1ddcdc DM |
3587 | qemu-server (2.0-28) unstable; urgency=low |
3588 | ||
3589 | * use Digest::SHA instead of Digest::SHA1 | |
3590 | ||
3591 | -- Proxmox Support Team <support@proxmox.com> Tue, 20 Mar 2012 12:24:01 +0100 | |
3592 | ||
ed3ffe31 DM |
3593 | qemu-server (2.0-27) unstable; urgency=low |
3594 | ||
3595 | * make startall wait up to 10 seconds for quorum | |
3596 | ||
3597 | -- Proxmox Support Team <support@proxmox.com> Tue, 20 Mar 2012 09:32:53 +0100 | |
3598 | ||
28ef82d3 DM |
3599 | qemu-server (2.0-26) unstable; urgency=low |
3600 | ||
3601 | * fix bug 109: use scsi inquiry to test if we can use the scsi-block | |
3602 | driver. | |
3603 | ||
3604 | -- Proxmox Support Team <support@proxmox.com> Mon, 19 Mar 2012 10:39:30 +0100 | |
3605 | ||
961bfcb2 DM |
3606 | qemu-server (2.0-25) unstable; urgency=low |
3607 | ||
3608 | * fix bug 102: remove stale status file on stop | |
3609 | ||
3610 | -- Proxmox Support Team <support@proxmox.com> Thu, 01 Mar 2012 12:53:32 +0100 | |
3611 | ||
0581fe4f DM |
3612 | qemu-server (2.0-24) unstable; urgency=low |
3613 | ||
3614 | * save description as comment. | |
3615 | ||
3616 | -- Proxmox Support Team <support@proxmox.com> Thu, 01 Mar 2012 08:12:29 +0100 | |
3617 | ||
3f05af61 DM |
3618 | qemu-server (2.0-23) unstable; urgency=low |
3619 | ||
3620 | * fix lvremove call: avoid 'Not a CODE reference' warning | |
3621 | ||
3622 | -- Proxmox Support Team <support@proxmox.com> Thu, 01 Mar 2012 06:36:33 +0100 | |
3623 | ||
684bcdd7 DM |
3624 | qemu-server (2.0-22) unstable; urgency=low |
3625 | ||
3626 | * revert tablet mice fix - does not work reliable | |
3627 | ||
3628 | -- Proxmox Support Team <support@proxmox.com> Wed, 29 Feb 2012 09:45:30 +0100 | |
3629 | ||
ee88df81 DM |
3630 | qemu-server (2.0-21) unstable; urgency=low |
3631 | ||
3632 | * fix tablet mice as default when live migrate | |
3633 | ||
3634 | -- Proxmox Support Team <support@proxmox.com> Wed, 29 Feb 2012 06:51:09 +0100 | |
3635 | ||
b969cc68 DM |
3636 | qemu-server (2.0-20) unstable; urgency=low |
3637 | ||
3638 | * fix bug 96: fix vzdump on stopped vm | |
3639 | ||
3640 | -- Proxmox Support Team <support@proxmox.com> Fri, 24 Feb 2012 07:38:45 +0100 | |
3641 | ||
0aaaa6a4 DM |
3642 | qemu-server (2.0-19) unstable; urgency=low |
3643 | ||
3644 | * support more CPU models | |
3645 | ||
3646 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Feb 2012 07:18:53 +0100 | |
3647 | ||
f5782fd0 DM |
3648 | qemu-server (2.0-18) unstable; urgency=low |
3649 | ||
3650 | * fix cdrom (/dev/cdrom) permission check | |
3651 | ||
3652 | -- Proxmox Support Team <support@proxmox.com> Mon, 20 Feb 2012 07:16:36 +0100 | |
3653 | ||
49f9db93 DM |
3654 | qemu-server (2.0-17) unstable; urgency=low |
3655 | ||
3656 | * fix cdrom removal bug | |
3657 | ||
3658 | -- Proxmox Support Team <support@proxmox.com> Wed, 15 Feb 2012 10:48:30 +0100 | |
3659 | ||
da21653b DM |
3660 | qemu-server (2.0-16) unstable; urgency=low |
3661 | ||
3662 | * ignore -tdf (avoid kvm warning) - this is no longer needed | |
3663 | ||
3664 | -- Proxmox Support Team <support@proxmox.com> Mon, 13 Feb 2012 11:18:01 +0100 | |
3665 | ||
97439670 DM |
3666 | qemu-server (2.0-15) unstable; urgency=low |
3667 | ||
3668 | * online migration fix: close tunnel later, wait for connection close | |
254575e9 DM |
3669 | |
3670 | * fix bug #81: do no deactivate volumes in vzdump stop mode | |
97439670 DM |
3671 | |
3672 | -- Proxmox Support Team <support@proxmox.com> Tue, 17 Jan 2012 11:24:56 +0100 | |
3673 | ||
e95fe75f DM |
3674 | qemu-server (2.0-14) unstable; urgency=low |
3675 | ||
3676 | * use 'da' instead of 'dk' for Danish keyboard (qemu use that name) | |
3677 | ||
3678 | -- Proxmox Support Team <support@proxmox.com> Mon, 09 Jan 2012 11:24:40 +0100 | |
3679 | ||
31a9616c DM |
3680 | qemu-server (2.0-13) unstable; urgency=low |
3681 | ||
3682 | * load vhost_net module | |
3683 | ||
3684 | -- Proxmox Support Team <support@proxmox.com> Tue, 20 Dec 2011 12:25:22 +0100 | |
3685 | ||
9269013a DM |
3686 | qemu-server (2.0-12) unstable; urgency=low |
3687 | ||
3688 | * implement forceStop option for shutdown | |
3689 | ||
3690 | -- Proxmox Support Team <support@proxmox.com> Thu, 15 Dec 2011 12:58:00 +0100 | |
3691 | ||
1c060867 DM |
3692 | qemu-server (2.0-11) unstable; urgency=low |
3693 | ||
3694 | * do not use ehci by default | |
3695 | ||
3696 | -- Proxmox Support Team <support@proxmox.com> Thu, 08 Dec 2011 10:26:36 +0100 | |
3697 | ||
2372d114 DM |
3698 | qemu-server (2.0-10) unstable; urgency=low |
3699 | ||
3700 | * set qm exit codes currectly | |
3701 | ||
3702 | * fix 'qm shutdown <vmid>' | |
3703 | ||
3704 | -- Proxmox Support Team <support@proxmox.com> Wed, 30 Nov 2011 09:35:43 +0100 | |
3705 | ||
bbbe5146 DM |
3706 | qemu-server (2.0-9) unstable; urgency=low |
3707 | ||
3708 | * fix 'qm stopall' | |
3709 | ||
3710 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Nov 2011 11:14:01 +0100 | |
3711 | ||
f325c6d6 DM |
3712 | qemu-server (2.0-8) unstable; urgency=low |
3713 | ||
3714 | * be more careful when removing snapshots | |
3715 | ||
3716 | * do not call check_lock() for sendkey | |
3717 | ||
3718 | * try to detect errors before starting the background task | |
3719 | ||
3720 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Nov 2011 08:08:44 +0100 | |
3721 | ||
ff1a2432 DM |
3722 | qemu-server (2.0-7) unstable; urgency=low |
3723 | ||
3724 | * activate/deactivate LVs more carefully | |
3725 | ||
3726 | * avoid syslog whenever possible | |
3727 | ||
3728 | * code cleanups | |
3729 | ||
3730 | -- Proxmox Support Team <support@proxmox.com> Fri, 25 Nov 2011 08:08:04 +0100 | |
3731 | ||
48e1a963 DM |
3732 | qemu-server (2.0-6) unstable; urgency=low |
3733 | ||
3734 | * set correct migrate speed | |
3735 | ||
3736 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 Nov 2011 09:12:12 +0100 | |
3737 | ||
cf3298e6 DM |
3738 | qemu-server (2.0-5) unstable; urgency=low |
3739 | ||
3740 | * fix vzdump stop mode | |
3741 | ||
3742 | -- Proxmox Support Team <support@proxmox.com> Mon, 21 Nov 2011 06:38:03 +0100 | |
3743 | ||
2d8f7f21 DM |
3744 | qemu-server (2.0-4) unstable; urgency=low |
3745 | ||
3746 | * bump version | |
3747 | ||
3748 | -- Proxmox Support Team <support@proxmox.com> Sat, 19 Nov 2011 09:54:19 +0100 | |
3749 | ||
c274d9f9 DM |
3750 | qemu-server (2.0-3) unstable; urgency=low |
3751 | ||
3752 | * implement monitor API | |
3753 | ||
3754 | * implement qmrestore | |
3755 | ||
3756 | * fix vzdump plugin for 2.0 | |
3757 | ||
3758 | -- Proxmox Support Team <support@proxmox.com> Wed, 09 Nov 2011 11:35:58 +0100 | |
3759 | ||
be62c45c DM |
3760 | qemu-server (2.0-2) unstable; urgency=low |
3761 | ||
3762 | * cleanups | |
3763 | ||
3764 | -- Proxmox Support Team <support@proxmox.com> Wed, 05 Oct 2011 10:15:37 +0200 | |
3765 | ||
1e3baf05 DM |
3766 | qemu-server (2.0-1) unstable; urgency=low |
3767 | ||
3768 | * see Changelog for details | |
3769 | ||
3770 | -- Proxmox Support Team <support@proxmox.com> Thu, 26 Aug 2010 13:48:12 +0200 | |
3771 | ||
3772 | qemu-server (1.1-18) unstable; urgency=low | |
3773 | ||
3774 | * small bug fix im qmigrate | |
3775 | ||
3776 | -- Proxmox Support Team <support@proxmox.com> Fri, 20 Aug 2010 08:05:21 +0200 | |
3777 | ||
3778 | qemu-server (1.1-17) unstable; urgency=low | |
3779 | ||
3780 | * carefully catch write errors | |
3781 | ||
3782 | -- Proxmox Support Team <support@proxmox.com> Mon, 19 Jul 2010 09:00:48 +0200 | |
3783 | ||
3784 | qemu-server (1.1-16) unstable; urgency=low | |
3785 | ||
3786 | * add rerror/werror options (patch from l.mierzwa) | |
3787 | ||
3788 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Jun 2010 08:49:00 +0200 | |
3789 | ||
3790 | qemu-server (1.1-15) unstable; urgency=low | |
3791 | ||
3792 | * fix vmtar bug (endless growing archive) | |
3793 | ||
3794 | -- Proxmox Support Team <support@proxmox.com> Fri, 25 Jun 2010 12:22:17 +0200 | |
3795 | ||
3796 | qemu-server (1.1-14) unstable; urgency=low | |
3797 | ||
3798 | * correct order of config option (prevent virtio reordering) | |
3799 | ||
3800 | -- Proxmox Support Team <support@proxmox.com> Wed, 28 Apr 2010 09:05:15 +0200 | |
3801 | ||
3802 | qemu-server (1.1-13) unstable; urgency=low | |
3803 | ||
3804 | * allow vlan1-to vlan4094 (Since 802.1q allows VLAN identifiers up to 4094). | |
3805 | ||
3806 | -- Proxmox Support Team <support@proxmox.com> Wed, 21 Apr 2010 10:19:37 +0200 | |
3807 | ||
3808 | qemu-server (1.1-12) unstable; urgency=low | |
3809 | ||
3810 | * minor fixes for new qemu-kvm 0.12.3 | |
3811 | ||
3812 | -- Proxmox Support Team <support@proxmox.com> Fri, 16 Apr 2010 12:01:17 +0200 | |
3813 | ||
3814 | qemu-server (1.1-11) unstable; urgency=low | |
3815 | ||
3816 | * experimental support for pci pass-through (option 'hostpci') | |
3817 | ||
3818 | -- Proxmox Support Team <support@proxmox.com> Fri, 08 Jan 2010 13:03:44 +0100 | |
3819 | ||
3820 | qemu-server (1.1-10) unstable; urgency=low | |
3821 | ||
3822 | * add compatibility code for older kvm versions (0.9) | |
3823 | ||
3824 | * only use fairsched when the kernel has openvz support | |
3825 | ||
3826 | -- Proxmox Support Team <support@proxmox.com> Fri, 04 Dec 2009 15:17:18 +0100 | |
3827 | ||
3828 | qemu-server (1.1-9) unstable; urgency=low | |
3829 | ||
3830 | * always display boot menu (Press F12...) | |
3831 | ||
3832 | -- Proxmox Support Team <support@proxmox.com> Wed, 28 Oct 2009 10:28:23 +0100 | |
3833 | ||
3834 | qemu-server (1.1-8) unstable; urgency=low | |
3835 | ||
3836 | * fix 'stopall' timeout | |
3837 | ||
3838 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Oct 2009 12:55:23 +0200 | |
3839 | ||
3840 | qemu-server (1.1-7) unstable; urgency=low | |
3841 | ||
3842 | * do not set fairsched --id when using virtio | |
3843 | ||
3844 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Oct 2009 11:57:57 +0200 | |
3845 | ||
3846 | qemu-server (1.1-6) unstable; urgency=low | |
3847 | ||
3848 | * disable fairsched when option 'cpuunits' is set to 0 (zero) | |
3849 | ||
3850 | * disable fairsched when the VM uses virtio devices. | |
3851 | ||
3852 | -- Proxmox Support Team <support@proxmox.com> Thu, 15 Oct 2009 15:06:48 +0200 | |
3853 | ||
3854 | qemu-server (1.1-5) unstable; urgency=low | |
3855 | ||
3856 | * suppress syslog when setting migrate downtime/speed | |
3857 | ||
3858 | -- Proxmox Support Team <support@proxmox.com> Tue, 06 Oct 2009 10:10:55 +0200 | |
3859 | ||
3860 | qemu-server (1.1-4) unstable; urgency=low | |
3861 | ||
3862 | * depend on stable pve-qemu-kvm | |
3863 | ||
3864 | * new migrate_speed and migrate_downtime settings | |
3865 | ||
3866 | -- Proxmox Support Team <support@proxmox.com> Mon, 28 Sep 2009 11:18:08 +0200 | |
3867 | ||
3868 | qemu-server (1.1-3) unstable; urgency=low | |
3869 | ||
3870 | * support up to 1000 vlans | |
3871 | ||
3872 | -- Proxmox Support Team <support@proxmox.com> Fri, 18 Sep 2009 09:54:35 +0200 | |
3873 | ||
3874 | qemu-server (1.1-2) unstable; urgency=low | |
3875 | ||
3876 | * introduce new 'sockets' and 'cores' settings | |
3877 | ||
3878 | -- Proxmox Support Team <support@proxmox.com> Fri, 18 Sep 2009 09:54:18 +0200 | |
3879 | ||
3880 | qemu-server (1.1-1) unstable; urgency=low | |
3881 | ||
3882 | * use new pve-storage framework | |
3883 | ||
3884 | * delete unused disk on destroy | |
3885 | ||
3886 | * fix cache= option (none|writethrough|writeback) | |
3887 | ||
3888 | * use rtc-td-hack for windows when acpi is enabled | |
3889 | ||
3890 | -- Proxmox Support Team <support@proxmox.com> Thu, 25 Jun 2009 08:49:53 +0200 | |
3891 | ||
3892 | qemu-server (1.0-14) unstable; urgency=low | |
3893 | ||
3894 | * add new tablet option (to disable --usbdevice tablet, which generate | |
3895 | many interrupts, which is bad when you run many VMs) (Patch was | |
3896 | provided by Tomasz Chmielewski) | |
3897 | ||
3898 | -- Proxmox Support Team <support@proxmox.com> Wed, 27 May 2009 12:50:45 +0200 | |
3899 | ||
3900 | qemu-server (1.0-13) unstable; urgency=low | |
3901 | ||
3902 | * Conflict with netcat-openbsd | |
3903 | ||
3904 | -- Proxmox Support Team <support@proxmox.com> Wed, 13 May 2009 10:20:54 +0200 | |
3905 | ||
3906 | qemu-server (1.0-12) unstable; urgency=low | |
3907 | ||
3908 | * fixes for debian lenny | |
3909 | ||
3910 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Apr 2009 14:28:42 +0200 | |
3911 | ||
3912 | qemu-server (1.0-11) unstable; urgency=low | |
3913 | ||
3914 | * allow white spaces inside args - use normal shell quoting | |
3915 | ||
3916 | -- Proxmox Support Team <support@proxmox.com> Thu, 26 Feb 2009 11:31:36 +0100 | |
3917 | ||
3918 | qemu-server (1.0-10) unstable; urgency=low | |
3919 | ||
3920 | * add 'args' option | |
3921 | ||
3922 | * bug fix for 'lost description' | |
3923 | ||
3924 | -- Proxmox Support Team <support@proxmox.com> Wed, 11 Feb 2009 08:18:29 +0100 | |
3925 | ||
3926 | qemu-server (1.0-9) unstable; urgency=low | |
3927 | ||
3928 | * add 'parallel' option | |
3929 | ||
3930 | * add 'startdate' option | |
3931 | ||
3932 | * fix manual page | |
3933 | ||
3934 | -- Proxmox Support Team <support@proxmox.com> Mon, 2 Feb 2009 08:53:26 +0100 | |
3935 | ||
3936 | qemu-server (1.0-8) unstable; urgency=low | |
3937 | ||
3938 | * add 'serial' option | |
3939 | ||
3940 | -- Proxmox Support Team <support@proxmox.com> Mon, 20 Jan 2009 08:52:24 +0100 | |
3941 | ||
3942 | qemu-server (1.0-7) unstable; urgency=low | |
3943 | ||
3944 | * use new systax for kvm vga option (needed for kvm newer than kvm77) | |
3945 | ||
3946 | -- Proxmox Support Team <support@proxmox.com> Wed, 7 Jan 2009 14:46:09 +0100 | |
3947 | ||
3948 | qemu-server (1.0-6) unstable; urgency=low | |
3949 | ||
3950 | * use predefined names for tap devices | |
3951 | ||
3952 | -- Proxmox Support Team <support@proxmox.com> Fri, 19 Dec 2008 13:00:44 +0100 | |
3953 | ||
3954 | qemu-server (1.0-5) unstable; urgency=low | |
3955 | ||
3956 | * added host usb device support | |
3957 | ||
3958 | -- Proxmox Support Team <support@proxmox.com> Mon, 17 Nov 2008 11:26:04 +0100 | |
3959 | ||
3960 | qemu-server (1.0-4) unstable; urgency=low | |
3961 | ||
3962 | * fix status problem | |
3963 | ||
3964 | -- Proxmox Support Team <support@proxmox.com> Thu, 13 Nov 2008 13:13:43 +0100 | |
3965 | ||
3966 | qemu-server (1.0-3) unstable; urgency=low | |
3967 | ||
3968 | * small bug fixes | |
3969 | ||
3970 | -- Proxmox Support Team <support@proxmox.com> Tue, 11 Nov 2008 08:29:23 +0100 | |
3971 | ||
3972 | qemu-server (1.0-1) unstable; urgency=low | |
3973 | ||
3974 | * update for kvm-75, support vm migration | |
3975 | ||
3976 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Oct 2008 11:04:03 +0200 | |
3977 | ||
3978 | qemu-server (0.9) unstable; urgency=low | |
3979 | ||
3980 | * initial release | |
3981 | ||
3982 | -- Proxmox Support Team <support@proxmox.com> Mon, 4 Feb 2008 09:10:13 +0100 | |
3983 |