1`acpi`: `<boolean>` ('default =' `1`)::
2
3Enable/disable ACPI.
4
5`agent`: `[enabled=]<1|0> [,fstrim_cloned_disks=<1|0>]` ::
6
7Enable/disable Qemu GuestAgent and its properties.
8
9`enabled`=`<boolean>` ('default =' `0`);;
10
11Enable/disable Qemu GuestAgent.
12
13`fstrim_cloned_disks`=`<boolean>` ('default =' `0`);;
14
15Run fstrim after cloning/moving a disk.
16
17`arch`: `<aarch64 | x86_64>` ::
18
19Virtual processor architecture. Defaults to the host.
20
21`args`: `<string>` ::
22
23Arbitrary arguments passed to kvm, for example:
24+
25args: -no-reboot -no-hpet
26+
27NOTE: this option is for experts only.
28
29`autostart`: `<boolean>` ('default =' `0`)::
30
31Automatic restart after crash (currently ignored).
32
33`balloon`: `<integer> (0 - N)` ::
34
35Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
36
37`bios`: `<ovmf | seabios>` ('default =' `seabios`)::
38
39Select BIOS implementation.
40
41`boot`: `[acdn]{1,4}` ('default =' `cdn`)::
42
43Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n).
44
45`bootdisk`: `(ide|sata|scsi|virtio)\d+` ::
46
47Enable booting from specified disk.
48
49`cdrom`: `<volume>` ::
50
51This is an alias for option -ide2
52
53`cicustom`: `[meta=<volume>] [,network=<volume>] [,user=<volume>]` ::
54
55cloud-init: Specify custom files to replace the automatically generated ones at start.
56
57`meta`=`<volume>` ;;
58
59Specify a custom file containing all meta data passed to the VM via cloud-init. This is provider specific meaning configdrive2 and nocloud differ.
60
61`network`=`<volume>` ;;
62
63Specify a custom file containing all network data passed to the VM via cloud-init.
64
65`user`=`<volume>` ;;
66
67Specify a custom file containing all user data passed to the VM via cloud-init.
68
69`cipassword`: `<string>` ::
70
71cloud-init: Password to assign the user. Using this is generally not recommended. Use ssh keys instead. Also note that older cloud-init versions do not support hashed passwords.
72
73`citype`: `<configdrive2 | nocloud>` ::
74
75Specifies the cloud-init configuration format. The default depends on the configured operating system type (`ostype`. We use the `nocloud` format for Linux, and `configdrive2` for windows.
76
77`ciuser`: `<string>` ::
78
79cloud-init: User name to change ssh keys and password for instead of the image's configured default user.
80
81`cores`: `<integer> (1 - N)` ('default =' `1`)::
82
83The number of cores per socket.
84
85`cpu`: `[cputype=]<enum> [,flags=<+FLAG[;-FLAG...]>] [,hidden=<1|0>] [,hv-vendor-id=<vendor-id>]` ::
86
87Emulated CPU type.
88
89`cputype`=`<486 | Broadwell | Broadwell-IBRS | Broadwell-noTSX | Broadwell-noTSX-IBRS | Conroe | EPYC | EPYC-IBPB | Haswell | Haswell-IBRS | Haswell-noTSX | Haswell-noTSX-IBRS | IvyBridge | IvyBridge-IBRS | Nehalem | Nehalem-IBRS | Opteron_G1 | Opteron_G2 | Opteron_G3 | Opteron_G4 | Opteron_G5 | Penryn | SandyBridge | SandyBridge-IBRS | Skylake-Client | Skylake-Client-IBRS | Skylake-Server | Skylake-Server-IBRS | Westmere | Westmere-IBRS | athlon | core2duo | coreduo | host | kvm32 | kvm64 | max | pentium | pentium2 | pentium3 | phenom | qemu32 | qemu64>` ('default =' `kvm64`);;
90
91Emulated CPU type.
92
93`flags`=`<+FLAG[;-FLAG...]>` ;;
94
95List of additional CPU flags separated by ';'. Use '+FLAG' to enable, '-FLAG' to disable a flag. Currently supported flags: 'pcid', 'spec-ctrl', 'ibpb', 'ssbd', 'virt-ssbd', 'amd-ssbd', 'amd-no-ssb', 'pdpe1gb', 'md-clear'.
96
97`hidden`=`<boolean>` ('default =' `0`);;
98
99Do not identify as a KVM virtual machine.
100
101`hv-vendor-id`=`<vendor-id>` ;;
102
103The Hyper-V vendor ID. Some drivers or programs inside Windows guests need a specific ID.
104
105`cpulimit`: `<number> (0 - 128)` ('default =' `0`)::
106
107Limit of CPU usage.
108+
109NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.
110
111`cpuunits`: `<integer> (2 - 262144)` ('default =' `1024`)::
112
113CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.
114
115`description`: `<string>` ::
116
117Description for the VM. Only used on the configuration web interface. This is saved as comment inside the configuration file.
118
119`efidisk0`: `[file=]<volume> [,format=<enum>] [,size=<DiskSize>]` ::
120
121Configure a Disk for storing EFI vars
122
123`file`=`<volume>` ;;
124
125The drive's backing volume.
126
127`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
128
129The drive's backing file's data format.
130
131`size`=`<DiskSize>` ;;
132
133Disk size. This is purely informational and has no effect.
134
135`freeze`: `<boolean>` ::
136
137Freeze CPU at startup (use 'c' monitor command to start execution).
138
139`hookscript`: `<string>` ::
140
141Script that will be executed during various steps in the vms lifetime.
142
143`hostpci[n]`: `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,mdev=<string>] [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,x-vga=<1|0>]` ::
144
145Map host PCI devices into guest.
146+
147NOTE: This option allows direct access to host hardware. So it is no longer
148possible to migrate such machines - use with special care.
149+
150CAUTION: Experimental! User reported problems with this option.
151
152`host`=`<HOSTPCIID[;HOSTPCIID2...]>` ;;
153
154Host PCI device pass through. The PCI ID of a host's PCI device or a list
155of PCI virtual functions of the host. HOSTPCIID syntax is:
156+
157'bus:dev.func' (hexadecimal numbers)
158+
159You can us the 'lspci' command to list existing PCI devices.
160
161`mdev`=`<string>` ;;
162
163The type of mediated device to use.
164An instance of this type will be created on startup of the VM and
165will be cleaned up when the VM stops.
166
167`pcie`=`<boolean>` ('default =' `0`);;
168
169Choose the PCI-express bus (needs the 'q35' machine model).
170
171`rombar`=`<boolean>` ('default =' `1`);;
172
173Specify whether or not the device's ROM will be visible in the guest's memory map.
174
175`romfile`=`<string>` ;;
176
177Custom pci device rom filename (must be located in /usr/share/kvm/).
178
179`x-vga`=`<boolean>` ('default =' `0`);;
180
181Enable vfio-vga device support.
182
183`hotplug`: `<string>` ('default =' `network,disk,usb`)::
184
185Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.
186
187`hugepages`: `<1024 | 2 | any>` ::
188
189Enable/disable hugepages memory.
190
191`ide[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
192
193Use volume as IDE hard disk or CD-ROM (n is 0 to 3).
194
195`aio`=`<native | threads>` ;;
196
197AIO type to use.
198
199`backup`=`<boolean>` ;;
200
201Whether the drive should be included when making backups.
202
203`bps`=`<bps>` ;;
204
205Maximum r/w speed in bytes per second.
206
207`bps_max_length`=`<seconds>` ;;
208
209Maximum length of I/O bursts in seconds.
210
211`bps_rd`=`<bps>` ;;
212
213Maximum read speed in bytes per second.
214
215`bps_rd_max_length`=`<seconds>` ;;
216
217Maximum length of read I/O bursts in seconds.
218
219`bps_wr`=`<bps>` ;;
220
221Maximum write speed in bytes per second.
222
223`bps_wr_max_length`=`<seconds>` ;;
224
225Maximum length of write I/O bursts in seconds.
226
227`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
228
229The drive's cache mode
230
231`cyls`=`<integer>` ;;
232
233Force the drive's physical geometry to have a specific cylinder count.
234
235`detect_zeroes`=`<boolean>` ;;
236
237Controls whether to detect and try to optimize writes of zeroes.
238
239`discard`=`<ignore | on>` ;;
240
241Controls whether to pass discard/trim requests to the underlying storage.
242
243`file`=`<volume>` ;;
244
245The drive's backing volume.
246
247`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
248
249The drive's backing file's data format.
250
251`heads`=`<integer>` ;;
252
253Force the drive's physical geometry to have a specific head count.
254
255`iops`=`<iops>` ;;
256
257Maximum r/w I/O in operations per second.
258
259`iops_max`=`<iops>` ;;
260
261Maximum unthrottled r/w I/O pool in operations per second.
262
263`iops_max_length`=`<seconds>` ;;
264
265Maximum length of I/O bursts in seconds.
266
267`iops_rd`=`<iops>` ;;
268
269Maximum read I/O in operations per second.
270
271`iops_rd_max`=`<iops>` ;;
272
273Maximum unthrottled read I/O pool in operations per second.
274
275`iops_rd_max_length`=`<seconds>` ;;
276
277Maximum length of read I/O bursts in seconds.
278
279`iops_wr`=`<iops>` ;;
280
281Maximum write I/O in operations per second.
282
283`iops_wr_max`=`<iops>` ;;
284
285Maximum unthrottled write I/O pool in operations per second.
286
287`iops_wr_max_length`=`<seconds>` ;;
288
289Maximum length of write I/O bursts in seconds.
290
291`mbps`=`<mbps>` ;;
292
293Maximum r/w speed in megabytes per second.
294
295`mbps_max`=`<mbps>` ;;
296
297Maximum unthrottled r/w pool in megabytes per second.
298
299`mbps_rd`=`<mbps>` ;;
300
301Maximum read speed in megabytes per second.
302
303`mbps_rd_max`=`<mbps>` ;;
304
305Maximum unthrottled read pool in megabytes per second.
306
307`mbps_wr`=`<mbps>` ;;
308
309Maximum write speed in megabytes per second.
310
311`mbps_wr_max`=`<mbps>` ;;
312
313Maximum unthrottled write pool in megabytes per second.
314
315`media`=`<cdrom | disk>` ('default =' `disk`);;
316
317The drive's media type.
318
319`model`=`<model>` ;;
320
321The drive's reported model name, url-encoded, up to 40 bytes long.
322
323`replicate`=`<boolean>` ('default =' `1`);;
324
325Whether the drive should considered for replication jobs.
326
327`rerror`=`<ignore | report | stop>` ;;
328
329Read error action.
330
331`secs`=`<integer>` ;;
332
333Force the drive's physical geometry to have a specific sector count.
334
335`serial`=`<serial>` ;;
336
337The drive's reported serial number, url-encoded, up to 20 bytes long.
338
339`shared`=`<boolean>` ('default =' `0`);;
340
341Mark this locally-managed volume as available on all nodes.
342+
343WARNING: This option does not share the volume automatically, it assumes it is shared already!
344
345`size`=`<DiskSize>` ;;
346
347Disk size. This is purely informational and has no effect.
348
349`snapshot`=`<boolean>` ;;
350
351Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
352
353`ssd`=`<boolean>` ;;
354
355Whether to expose this drive as an SSD, rather than a rotational hard disk.
356
357`trans`=`<auto | lba | none>` ;;
358
359Force disk geometry bios translation mode.
360
361`werror`=`<enospc | ignore | report | stop>` ;;
362
363Write error action.
364
365`wwn`=`<wwn>` ;;
366
367The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
368
369`ipconfig[n]`: `[gw=<GatewayIPv4>] [,gw6=<GatewayIPv6>] [,ip=<IPv4Format/CIDR>] [,ip6=<IPv6Format/CIDR>]` ::
370
371cloud-init: Specify IP addresses and gateways for the corresponding interface.
372+
373IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
374+
375The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit gateway should be provided.
376For IPv6 the special string 'auto' can be used to use stateless autoconfiguration.
377+
378If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using dhcp on IPv4.
379
380`gw`=`<GatewayIPv4>` ;;
381
382Default gateway for IPv4 traffic.
383+
384NOTE: Requires option(s): `ip`
385
386`gw6`=`<GatewayIPv6>` ;;
387
388Default gateway for IPv6 traffic.
389+
390NOTE: Requires option(s): `ip6`
391
392`ip`=`<IPv4Format/CIDR>` ('default =' `dhcp`);;
393
394IPv4 address in CIDR format.
395
396`ip6`=`<IPv6Format/CIDR>` ('default =' `dhcp`);;
397
398IPv6 address in CIDR format.
399
400`ivshmem`: `size=<integer> [,name=<string>]` ::
401
402Inter-VM shared memory. Useful for direct communication between VMs, or to the host.
403
404`name`=`<string>` ;;
405
406The name of the file. Will be prefixed with 'pve-shm-'. Default is the VMID. Will be deleted when the VM is stopped.
407
408`size`=`<integer> (1 - N)` ;;
409
410The size of the file in MB.
411
412`keyboard`: `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ::
413
414Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.cfg' configuration file.It should not be necessary to set it.
415
416`kvm`: `<boolean>` ('default =' `1`)::
417
418Enable/disable KVM hardware virtualization.
419
420`localtime`: `<boolean>` ::
421
422Set the real time clock to local time. This is enabled by default if ostype indicates a Microsoft OS.
423
424`lock`: `<backup | clone | create | migrate | rollback | snapshot | snapshot-delete | suspended | suspending>` ::
425
426Lock/unlock the VM.
427
428`machine`: `(pc|pc(-i440fx)?-\d+\.\d+(\.pxe)?|q35|pc-q35-\d+\.\d+(\.pxe)?|virt(?:-\d+\.\d+)?)` ::
429
430Specifies the Qemu machine type.
431
432`memory`: `<integer> (16 - N)` ('default =' `512`)::
433
434Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
435
436`migrate_downtime`: `<number> (0 - N)` ('default =' `0.1`)::
437
438Set maximum tolerated downtime (in seconds) for migrations.
439
440`migrate_speed`: `<integer> (0 - N)` ('default =' `0`)::
441
442Set maximum speed (in MB/s) for migrations. Value 0 is no limit.
443
444`name`: `<string>` ::
445
446Set a name for the VM. Only used on the configuration web interface.
447
448`nameserver`: `<string>` ::
449
450cloud-init: Sets DNS server IP address for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
451
452`net[n]`: `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
453
454Specify network devices.
455
456`bridge`=`<bridge>` ;;
457
458Bridge to attach the network device to. The Proxmox VE standard bridge
459is called 'vmbr0'.
460+
461If you do not specify a bridge, we create a kvm user (NATed) network
462device, which provides DHCP and DNS services. The following addresses
463are used:
464+
465 10.0.2.2 Gateway
466 10.0.2.3 DNS Server
467 10.0.2.4 SMB Server
468+
469The DHCP server assign addresses to the guest starting from 10.0.2.15.
470
471`firewall`=`<boolean>` ;;
472
473Whether this interface should be protected by the firewall.
474
475`link_down`=`<boolean>` ;;
476
477Whether this interface should be disconnected (like pulling the plug).
478
479`macaddr`=`<XX:XX:XX:XX:XX:XX>` ;;
480
481A common MAC address with the I/G (Individual/Group) bit not set.
482
483`model`=`<e1000 | e1000-82540em | e1000-82544gc | e1000-82545em | i82551 | i82557b | i82559er | ne2k_isa | ne2k_pci | pcnet | rtl8139 | virtio | vmxnet3>` ;;
484
485Network Card Model. The 'virtio' model provides the best performance with very low CPU overhead. If your guest does not support this driver, it is usually best to use 'e1000'.
486
487`queues`=`<integer> (0 - 16)` ;;
488
489Number of packet queues to be used on the device.
490
491`rate`=`<number> (0 - N)` ;;
492
493Rate limit in mbps (megabytes per second) as floating point number.
494
495`tag`=`<integer> (1 - 4094)` ;;
496
497VLAN tag to apply to packets on this interface.
498
499`trunks`=`<vlanid[;vlanid...]>` ;;
500
501VLAN trunks to pass through this interface.
502
503`numa`: `<boolean>` ('default =' `0`)::
504
505Enable/disable NUMA.
506
507`numa[n]`: `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<number>] [,policy=<preferred|bind|interleave>]` ::
508
509NUMA topology.
510
511`cpus`=`<id[-id];...>` ;;
512
513CPUs accessing this NUMA node.
514
515`hostnodes`=`<id[-id];...>` ;;
516
517Host NUMA nodes to use.
518
519`memory`=`<number>` ;;
520
521Amount of memory this NUMA node provides.
522
523`policy`=`<bind | interleave | preferred>` ;;
524
525NUMA allocation policy.
526
527`onboot`: `<boolean>` ('default =' `0`)::
528
529Specifies whether a VM will be started during system bootup.
530
531`ostype`: `<l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win10 | win7 | win8 | wvista | wxp>` ::
532
533Specify guest operating system. This is used to enable special
534optimization/features for specific operating systems:
535+
536[horizontal]
537other;; unspecified OS
538wxp;; Microsoft Windows XP
539w2k;; Microsoft Windows 2000
540w2k3;; Microsoft Windows 2003
541w2k8;; Microsoft Windows 2008
542wvista;; Microsoft Windows Vista
543win7;; Microsoft Windows 7
544win8;; Microsoft Windows 8/2012/2012r2
545win10;; Microsoft Windows 10/2016
546l24;; Linux 2.4 Kernel
547l26;; Linux 2.6/3.X Kernel
548solaris;; Solaris/OpenSolaris/OpenIndiania kernel
549
550`parallel[n]`: `/dev/parport\d+|/dev/usb/lp\d+` ::
551
552Map host parallel devices (n is 0 to 2).
553+
554NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such machines - use with special care.
555+
556CAUTION: Experimental! User reported problems with this option.
557
558`protection`: `<boolean>` ('default =' `0`)::
559
560Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.
561
562`reboot`: `<boolean>` ('default =' `1`)::
563
564Allow reboot. If set to '0' the VM exit on reboot.
565
566`sata[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
567
568Use volume as SATA hard disk or CD-ROM (n is 0 to 5).
569
570`aio`=`<native | threads>` ;;
571
572AIO type to use.
573
574`backup`=`<boolean>` ;;
575
576Whether the drive should be included when making backups.
577
578`bps`=`<bps>` ;;
579
580Maximum r/w speed in bytes per second.
581
582`bps_max_length`=`<seconds>` ;;
583
584Maximum length of I/O bursts in seconds.
585
586`bps_rd`=`<bps>` ;;
587
588Maximum read speed in bytes per second.
589
590`bps_rd_max_length`=`<seconds>` ;;
591
592Maximum length of read I/O bursts in seconds.
593
594`bps_wr`=`<bps>` ;;
595
596Maximum write speed in bytes per second.
597
598`bps_wr_max_length`=`<seconds>` ;;
599
600Maximum length of write I/O bursts in seconds.
601
602`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
603
604The drive's cache mode
605
606`cyls`=`<integer>` ;;
607
608Force the drive's physical geometry to have a specific cylinder count.
609
610`detect_zeroes`=`<boolean>` ;;
611
612Controls whether to detect and try to optimize writes of zeroes.
613
614`discard`=`<ignore | on>` ;;
615
616Controls whether to pass discard/trim requests to the underlying storage.
617
618`file`=`<volume>` ;;
619
620The drive's backing volume.
621
622`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
623
624The drive's backing file's data format.
625
626`heads`=`<integer>` ;;
627
628Force the drive's physical geometry to have a specific head count.
629
630`iops`=`<iops>` ;;
631
632Maximum r/w I/O in operations per second.
633
634`iops_max`=`<iops>` ;;
635
636Maximum unthrottled r/w I/O pool in operations per second.
637
638`iops_max_length`=`<seconds>` ;;
639
640Maximum length of I/O bursts in seconds.
641
642`iops_rd`=`<iops>` ;;
643
644Maximum read I/O in operations per second.
645
646`iops_rd_max`=`<iops>` ;;
647
648Maximum unthrottled read I/O pool in operations per second.
649
650`iops_rd_max_length`=`<seconds>` ;;
651
652Maximum length of read I/O bursts in seconds.
653
654`iops_wr`=`<iops>` ;;
655
656Maximum write I/O in operations per second.
657
658`iops_wr_max`=`<iops>` ;;
659
660Maximum unthrottled write I/O pool in operations per second.
661
662`iops_wr_max_length`=`<seconds>` ;;
663
664Maximum length of write I/O bursts in seconds.
665
666`mbps`=`<mbps>` ;;
667
668Maximum r/w speed in megabytes per second.
669
670`mbps_max`=`<mbps>` ;;
671
672Maximum unthrottled r/w pool in megabytes per second.
673
674`mbps_rd`=`<mbps>` ;;
675
676Maximum read speed in megabytes per second.
677
678`mbps_rd_max`=`<mbps>` ;;
679
680Maximum unthrottled read pool in megabytes per second.
681
682`mbps_wr`=`<mbps>` ;;
683
684Maximum write speed in megabytes per second.
685
686`mbps_wr_max`=`<mbps>` ;;
687
688Maximum unthrottled write pool in megabytes per second.
689
690`media`=`<cdrom | disk>` ('default =' `disk`);;
691
692The drive's media type.
693
694`replicate`=`<boolean>` ('default =' `1`);;
695
696Whether the drive should considered for replication jobs.
697
698`rerror`=`<ignore | report | stop>` ;;
699
700Read error action.
701
702`secs`=`<integer>` ;;
703
704Force the drive's physical geometry to have a specific sector count.
705
706`serial`=`<serial>` ;;
707
708The drive's reported serial number, url-encoded, up to 20 bytes long.
709
710`shared`=`<boolean>` ('default =' `0`);;
711
712Mark this locally-managed volume as available on all nodes.
713+
714WARNING: This option does not share the volume automatically, it assumes it is shared already!
715
716`size`=`<DiskSize>` ;;
717
718Disk size. This is purely informational and has no effect.
719
720`snapshot`=`<boolean>` ;;
721
722Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
723
724`ssd`=`<boolean>` ;;
725
726Whether to expose this drive as an SSD, rather than a rotational hard disk.
727
728`trans`=`<auto | lba | none>` ;;
729
730Force disk geometry bios translation mode.
731
732`werror`=`<enospc | ignore | report | stop>` ;;
733
734Write error action.
735
736`wwn`=`<wwn>` ;;
737
738The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
739
740`scsi[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
741
742Use volume as SCSI hard disk or CD-ROM (n is 0 to 13).
743
744`aio`=`<native | threads>` ;;
745
746AIO type to use.
747
748`backup`=`<boolean>` ;;
749
750Whether the drive should be included when making backups.
751
752`bps`=`<bps>` ;;
753
754Maximum r/w speed in bytes per second.
755
756`bps_max_length`=`<seconds>` ;;
757
758Maximum length of I/O bursts in seconds.
759
760`bps_rd`=`<bps>` ;;
761
762Maximum read speed in bytes per second.
763
764`bps_rd_max_length`=`<seconds>` ;;
765
766Maximum length of read I/O bursts in seconds.
767
768`bps_wr`=`<bps>` ;;
769
770Maximum write speed in bytes per second.
771
772`bps_wr_max_length`=`<seconds>` ;;
773
774Maximum length of write I/O bursts in seconds.
775
776`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
777
778The drive's cache mode
779
780`cyls`=`<integer>` ;;
781
782Force the drive's physical geometry to have a specific cylinder count.
783
784`detect_zeroes`=`<boolean>` ;;
785
786Controls whether to detect and try to optimize writes of zeroes.
787
788`discard`=`<ignore | on>` ;;
789
790Controls whether to pass discard/trim requests to the underlying storage.
791
792`file`=`<volume>` ;;
793
794The drive's backing volume.
795
796`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
797
798The drive's backing file's data format.
799
800`heads`=`<integer>` ;;
801
802Force the drive's physical geometry to have a specific head count.
803
804`iops`=`<iops>` ;;
805
806Maximum r/w I/O in operations per second.
807
808`iops_max`=`<iops>` ;;
809
810Maximum unthrottled r/w I/O pool in operations per second.
811
812`iops_max_length`=`<seconds>` ;;
813
814Maximum length of I/O bursts in seconds.
815
816`iops_rd`=`<iops>` ;;
817
818Maximum read I/O in operations per second.
819
820`iops_rd_max`=`<iops>` ;;
821
822Maximum unthrottled read I/O pool in operations per second.
823
824`iops_rd_max_length`=`<seconds>` ;;
825
826Maximum length of read I/O bursts in seconds.
827
828`iops_wr`=`<iops>` ;;
829
830Maximum write I/O in operations per second.
831
832`iops_wr_max`=`<iops>` ;;
833
834Maximum unthrottled write I/O pool in operations per second.
835
836`iops_wr_max_length`=`<seconds>` ;;
837
838Maximum length of write I/O bursts in seconds.
839
840`iothread`=`<boolean>` ;;
841
842Whether to use iothreads for this drive
843
844`mbps`=`<mbps>` ;;
845
846Maximum r/w speed in megabytes per second.
847
848`mbps_max`=`<mbps>` ;;
849
850Maximum unthrottled r/w pool in megabytes per second.
851
852`mbps_rd`=`<mbps>` ;;
853
854Maximum read speed in megabytes per second.
855
856`mbps_rd_max`=`<mbps>` ;;
857
858Maximum unthrottled read pool in megabytes per second.
859
860`mbps_wr`=`<mbps>` ;;
861
862Maximum write speed in megabytes per second.
863
864`mbps_wr_max`=`<mbps>` ;;
865
866Maximum unthrottled write pool in megabytes per second.
867
868`media`=`<cdrom | disk>` ('default =' `disk`);;
869
870The drive's media type.
871
872`queues`=`<integer> (2 - N)` ;;
873
874Number of queues.
875
876`replicate`=`<boolean>` ('default =' `1`);;
877
878Whether the drive should considered for replication jobs.
879
880`rerror`=`<ignore | report | stop>` ;;
881
882Read error action.
883
884`scsiblock`=`<boolean>` ('default =' `0`);;
885
886whether to use scsi-block for full passthrough of host block device
887+
888WARNING: can lead to I/O errors in combination with low memory or high memory fragmentation on host
889
890`secs`=`<integer>` ;;
891
892Force the drive's physical geometry to have a specific sector count.
893
894`serial`=`<serial>` ;;
895
896The drive's reported serial number, url-encoded, up to 20 bytes long.
897
898`shared`=`<boolean>` ('default =' `0`);;
899
900Mark this locally-managed volume as available on all nodes.
901+
902WARNING: This option does not share the volume automatically, it assumes it is shared already!
903
904`size`=`<DiskSize>` ;;
905
906Disk size. This is purely informational and has no effect.
907
908`snapshot`=`<boolean>` ;;
909
910Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
911
912`ssd`=`<boolean>` ;;
913
914Whether to expose this drive as an SSD, rather than a rotational hard disk.
915
916`trans`=`<auto | lba | none>` ;;
917
918Force disk geometry bios translation mode.
919
920`werror`=`<enospc | ignore | report | stop>` ;;
921
922Write error action.
923
924`wwn`=`<wwn>` ;;
925
926The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
927
928`scsihw`: `<lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single>` ('default =' `lsi`)::
929
930SCSI controller model
931
932`searchdomain`: `<string>` ::
933
934cloud-init: Sets DNS search domains for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
935
936`serial[n]`: `(/dev/.+|socket)` ::
937
938Create a serial device inside the VM (n is 0 to 3), and pass through a
939host serial device (i.e. /dev/ttyS0), or create a unix socket on the
940host side (use 'qm terminal' to open a terminal connection).
941+
942NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines - use with special care.
943+
944CAUTION: Experimental! User reported problems with this option.
945
946`shares`: `<integer> (0 - 50000)` ('default =' `1000`)::
947
948Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.
949
950`smbios1`: `[base64=<1|0>] [,family=<Base64 encoded string>] [,manufacturer=<Base64 encoded string>] [,product=<Base64 encoded string>] [,serial=<Base64 encoded string>] [,sku=<Base64 encoded string>] [,uuid=<UUID>] [,version=<Base64 encoded string>]` ::
951
952Specify SMBIOS type 1 fields.
953
954`base64`=`<boolean>` ;;
955
956Flag to indicate that the SMBIOS values are base64 encoded
957
958`family`=`<Base64 encoded string>` ;;
959
960Set SMBIOS1 family string.
961
962`manufacturer`=`<Base64 encoded string>` ;;
963
964Set SMBIOS1 manufacturer.
965
966`product`=`<Base64 encoded string>` ;;
967
968Set SMBIOS1 product ID.
969
970`serial`=`<Base64 encoded string>` ;;
971
972Set SMBIOS1 serial number.
973
974`sku`=`<Base64 encoded string>` ;;
975
976Set SMBIOS1 SKU string.
977
978`uuid`=`<UUID>` ;;
979
980Set SMBIOS1 UUID.
981
982`version`=`<Base64 encoded string>` ;;
983
984Set SMBIOS1 version.
985
986`smp`: `<integer> (1 - N)` ('default =' `1`)::
987
988The number of CPUs. Please use option -sockets instead.
989
990`sockets`: `<integer> (1 - N)` ('default =' `1`)::
991
992The number of CPU sockets.
993
994`sshkeys`: `<string>` ::
995
996cloud-init: Setup public SSH keys (one key per line, OpenSSH format).
997
998`startdate`: `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` ('default =' `now`)::
999
1000Set the initial date of the real time clock. Valid format for date are: 'now' or '2006-06-17T16:01:21' or '2006-06-17'.
1001
1002`startup`: `[[order=]\d+] [,up=\d+] [,down=\d+] ` ::
1003
1004Startup and shutdown behavior. Order is a non-negative number defining the general startup order. Shutdown in done with reverse ordering. Additionally you can set the 'up' or 'down' delay in seconds, which specifies a delay to wait before the next VM is started or stopped.
1005
1006`tablet`: `<boolean>` ('default =' `1`)::
1007
1008Enable/disable the USB tablet device. This device is usually needed to allow absolute mouse positioning with VNC. Else the mouse runs out of sync with normal VNC clients. If you're running lots of console-only guests on one host, you may consider disabling this to save some context switches. This is turned off by default if you use spice (-vga=qxl).
1009
1010`tdf`: `<boolean>` ('default =' `0`)::
1011
1012Enable/disable time drift fix.
1013
1014`template`: `<boolean>` ('default =' `0`)::
1015
1016Enable/disable Template.
1017
1018`unused[n]`: `<string>` ::
1019
1020Reference to unused volumes. This is used internally, and should not be modified manually.
1021
1022`usb[n]`: `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
1023
1024Configure an USB device (n is 0 to 4).
1025
1026`host`=`<HOSTUSBDEVICE|spice>` ;;
1027
1028The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
1029+
1030 'bus-port(.port)*' (decimal numbers) or
1031 'vendor_id:product_id' (hexadeciaml numbers) or
1032 'spice'
1033+
1034You can use the 'lsusb -t' command to list existing usb devices.
1035+
1036NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such machines - use with special care.
1037+
1038The value 'spice' can be used to add a usb redirection devices for spice.
1039
1040`usb3`=`<boolean>` ('default =' `0`);;
1041
1042Specifies whether if given host option is a USB3 device or port (this does currently not work reliably with spice redirection and is then ignored).
1043
1044`vcpus`: `<integer> (1 - N)` ('default =' `0`)::
1045
1046Number of hotplugged vcpus.
1047
1048`vga`: `[[type=]<enum>] [,memory=<integer>]` ::
1049
1050Configure the VGA Hardware. If you want to use high resolution modes (>= 1280x1024x16) you may need to increase the vga memory option. Since QEMU 2.9 the default VGA display type is 'std' for all OS types besides some Windows versions (XP and older) which use 'cirrus'. The 'qxl' option enables the SPICE display server. For win* OS you can select how many independent displays you want, Linux guests can add displays them self.
1051You can also run without any graphic card, using a serial device as terminal.
1052
1053`memory`=`<integer> (4 - 512)` ;;
1054
1055Sets the VGA memory (in MiB). Has no effect with serial display.
1056
1057`type`=`<cirrus | none | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | virtio | vmware>` ('default =' `std`);;
1058
1059Select the VGA type.
1060
1061`virtio[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
1062
1063Use volume as VIRTIO hard disk (n is 0 to 15).
1064
1065`aio`=`<native | threads>` ;;
1066
1067AIO type to use.
1068
1069`backup`=`<boolean>` ;;
1070
1071Whether the drive should be included when making backups.
1072
1073`bps`=`<bps>` ;;
1074
1075Maximum r/w speed in bytes per second.
1076
1077`bps_max_length`=`<seconds>` ;;
1078
1079Maximum length of I/O bursts in seconds.
1080
1081`bps_rd`=`<bps>` ;;
1082
1083Maximum read speed in bytes per second.
1084
1085`bps_rd_max_length`=`<seconds>` ;;
1086
1087Maximum length of read I/O bursts in seconds.
1088
1089`bps_wr`=`<bps>` ;;
1090
1091Maximum write speed in bytes per second.
1092
1093`bps_wr_max_length`=`<seconds>` ;;
1094
1095Maximum length of write I/O bursts in seconds.
1096
1097`cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
1098
1099The drive's cache mode
1100
1101`cyls`=`<integer>` ;;
1102
1103Force the drive's physical geometry to have a specific cylinder count.
1104
1105`detect_zeroes`=`<boolean>` ;;
1106
1107Controls whether to detect and try to optimize writes of zeroes.
1108
1109`discard`=`<ignore | on>` ;;
1110
1111Controls whether to pass discard/trim requests to the underlying storage.
1112
1113`file`=`<volume>` ;;
1114
1115The drive's backing volume.
1116
1117`format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
1118
1119The drive's backing file's data format.
1120
1121`heads`=`<integer>` ;;
1122
1123Force the drive's physical geometry to have a specific head count.
1124
1125`iops`=`<iops>` ;;
1126
1127Maximum r/w I/O in operations per second.
1128
1129`iops_max`=`<iops>` ;;
1130
1131Maximum unthrottled r/w I/O pool in operations per second.
1132
1133`iops_max_length`=`<seconds>` ;;
1134
1135Maximum length of I/O bursts in seconds.
1136
1137`iops_rd`=`<iops>` ;;
1138
1139Maximum read I/O in operations per second.
1140
1141`iops_rd_max`=`<iops>` ;;
1142
1143Maximum unthrottled read I/O pool in operations per second.
1144
1145`iops_rd_max_length`=`<seconds>` ;;
1146
1147Maximum length of read I/O bursts in seconds.
1148
1149`iops_wr`=`<iops>` ;;
1150
1151Maximum write I/O in operations per second.
1152
1153`iops_wr_max`=`<iops>` ;;
1154
1155Maximum unthrottled write I/O pool in operations per second.
1156
1157`iops_wr_max_length`=`<seconds>` ;;
1158
1159Maximum length of write I/O bursts in seconds.
1160
1161`iothread`=`<boolean>` ;;
1162
1163Whether to use iothreads for this drive
1164
1165`mbps`=`<mbps>` ;;
1166
1167Maximum r/w speed in megabytes per second.
1168
1169`mbps_max`=`<mbps>` ;;
1170
1171Maximum unthrottled r/w pool in megabytes per second.
1172
1173`mbps_rd`=`<mbps>` ;;
1174
1175Maximum read speed in megabytes per second.
1176
1177`mbps_rd_max`=`<mbps>` ;;
1178
1179Maximum unthrottled read pool in megabytes per second.
1180
1181`mbps_wr`=`<mbps>` ;;
1182
1183Maximum write speed in megabytes per second.
1184
1185`mbps_wr_max`=`<mbps>` ;;
1186
1187Maximum unthrottled write pool in megabytes per second.
1188
1189`media`=`<cdrom | disk>` ('default =' `disk`);;
1190
1191The drive's media type.
1192
1193`replicate`=`<boolean>` ('default =' `1`);;
1194
1195Whether the drive should considered for replication jobs.
1196
1197`rerror`=`<ignore | report | stop>` ;;
1198
1199Read error action.
1200
1201`secs`=`<integer>` ;;
1202
1203Force the drive's physical geometry to have a specific sector count.
1204
1205`serial`=`<serial>` ;;
1206
1207The drive's reported serial number, url-encoded, up to 20 bytes long.
1208
1209`shared`=`<boolean>` ('default =' `0`);;
1210
1211Mark this locally-managed volume as available on all nodes.
1212+
1213WARNING: This option does not share the volume automatically, it assumes it is shared already!
1214
1215`size`=`<DiskSize>` ;;
1216
1217Disk size. This is purely informational and has no effect.
1218
1219`snapshot`=`<boolean>` ;;
1220
1221Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
1222
1223`trans`=`<auto | lba | none>` ;;
1224
1225Force disk geometry bios translation mode.
1226
1227`werror`=`<enospc | ignore | report | stop>` ;;
1228
1229Write error action.
1230
1231`vmgenid`: `<UUID>` ('default =' `1 (autogenerated)`)::
1232
1233The VM generation ID (vmgenid) device exposes a 128-bit integer value identifier to the guest OS. This allows to notify the guest operating system when the virtual machine is executed with a different configuration (e.g. snapshot execution or creation from a template). The guest operating system notices the change, and is then able to react as appropriate by marking its copies of distributed databases as dirty, re-initializing its random number generator, etc.
1234Note that auto-creation only works when done throug API/CLI create or update methods, but not when manually editing the config file.
1235
1236`vmstatestorage`: `<string>` ::
1237
1238Default storage for VM state volumes/files.
1239
1240`watchdog`: `[[model=]<i6300esb|ib700>] [,action=<enum>]` ::
1241
1242Create a virtual hardware watchdog device. Once enabled (by a guest action), the watchdog must be periodically polled by an agent inside the guest or else the watchdog will reset the guest (or execute the respective action specified)
1243
1244`action`=`<debug | none | pause | poweroff | reset | shutdown>` ;;
1245
1246The action to perform if after activation the guest fails to poll the watchdog in time.
1247