]> git.proxmox.com Git - pve-docs.git/blobdiff - qm.conf.5-opts.adoc
totp: fix copy/paste mistake
[pve-docs.git] / qm.conf.5-opts.adoc
index 3548c2e0d9d23c18924ab88201d07b6fbcb3e4d4..da305545ad36b6eb51ea2b868248b3922cf6cd28 100644 (file)
@@ -2,13 +2,21 @@
 
 Enable/disable ACPI.
 
-`agent`: `[enabled=]<1|0> [,fstrim_cloned_disks=<1|0>] [,type=<virtio|isa>]` ::
+`affinity`: `<string>` ::
 
-Enable/disable communication with the Qemu Guest Agent and its properties.
+List of host cores used to execute guest processes, for example: 0,5,8-11
+
+`agent`: `[enabled=]<1|0> [,freeze-fs-on-backup=<1|0>] [,fstrim_cloned_disks=<1|0>] [,type=<virtio|isa>]` ::
+
+Enable/disable communication with the QEMU Guest Agent and its properties.
 
 `enabled`=`<boolean>` ('default =' `0`);;
 
-Enable/disable communication with a Qemu Guest Agent (QGA) running in the VM.
+Enable/disable communication with a QEMU Guest Agent (QGA) running in the VM.
+
+`freeze-fs-on-backup`=`<boolean>` ('default =' `1`);;
+
+Freeze/thaw guest filesystems on backup for consistency.
 
 `fstrim_cloned_disks`=`<boolean>` ('default =' `0`);;
 
@@ -26,7 +34,7 @@ Virtual processor architecture. Defaults to the host.
 
 Arbitrary arguments passed to kvm, for example:
 +
-args: -no-reboot -no-hpet
+args: -no-reboot -smbios 'type=0,vendor=FOO'
 +
 NOTE: this option is for experts only.
 
@@ -48,7 +56,7 @@ Automatic restart after crash (currently ignored).
 
 `balloon`: `<integer> (0 - N)` ::
 
-Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
+Amount of target RAM for the VM in MiB. Using zero disables the ballon driver.
 
 `bios`: `<ovmf | seabios>` ('default =' `seabios`)::
 
@@ -95,15 +103,15 @@ Specify a custom file containing all meta data passed to the VM via"
 
 `network`=`<volume>` ;;
 
-Specify a custom file containing all network data passed to the VM via cloud-init.
+To pass a custom file containing all network data to the VM via cloud-init.
 
 `user`=`<volume>` ;;
 
-Specify a custom file containing all user data passed to the VM via cloud-init.
+To pass a custom file containing all user data to the VM via cloud-init.
 
 `vendor`=`<volume>` ;;
 
-Specify a custom file containing all vendor data passed to the VM via cloud-init.
+To pass a custom file containing all vendor data to the VM via cloud-init.
 
 `cipassword`: `<string>` ::
 
@@ -113,6 +121,10 @@ cloud-init: Password to assign the user. Using this is generally not recommended
 
 Specifies the cloud-init configuration format. The default depends on the configured operating system type (`ostype`. We use the `nocloud` format for Linux, and `configdrive2` for windows.
 
+`ciupgrade`: `<boolean>` ('default =' `1`)::
+
+cloud-init: do an automatic package upgrade after the first boot.
+
 `ciuser`: `<string>` ::
 
 cloud-init: User name to change ssh keys and password for instead of the image's configured default user.
@@ -131,7 +143,7 @@ Emulated CPU type. Can be default or custom name (custom model names must be pre
 
 `flags`=`<+FLAG[;-FLAG...]>` ;;
 
-List of additional CPU flags separated by ';'. Use '+FLAG' to enable, '-FLAG' to disable a flag. Custom CPU models can specify any flag supported by QEMU/KVM, VM-specific flags must be from the following set for security reasons: pcid, spec-ctrl, ibpb, ssbd, virt-ssbd, amd-ssbd, amd-no-ssb, pdpe1gb, md-clear, hv-tlbflush, hv-evmcs, aes.
+List of additional CPU flags separated by ';'. Use '+FLAG' to enable, '-FLAG' to disable a flag. Custom CPU models can specify any flag supported by QEMU/KVM, VM-specific flags must be from the following set for security reasons: pcid, spec-ctrl, ibpb, ssbd, virt-ssbd, amd-ssbd, amd-no-ssb, pdpe1gb, md-clear, hv-tlbflush, hv-evmcs, aes
 
 `hidden`=`<boolean>` ('default =' `0`);;
 
@@ -145,7 +157,7 @@ The Hyper-V vendor ID. Some drivers or programs inside Windows guests need a spe
 
 The physical memory address bits that are reported to the guest OS. Should be smaller or equal to the host's. Set to 'host' to use value from host CPU, but note that doing so will break live migration to CPUs with other values.
 
-`reported-model`=`<486 | Broadwell | Broadwell-IBRS | Broadwell-noTSX | Broadwell-noTSX-IBRS | Cascadelake-Server | Cascadelake-Server-noTSX | Conroe | EPYC | EPYC-IBPB | EPYC-Rome | Haswell | Haswell-IBRS | Haswell-noTSX | Haswell-noTSX-IBRS | Icelake-Client | Icelake-Client-noTSX | Icelake-Server | Icelake-Server-noTSX | IvyBridge | IvyBridge-IBRS | KnightsMill | Nehalem | Nehalem-IBRS | Opteron_G1 | Opteron_G2 | Opteron_G3 | Opteron_G4 | Opteron_G5 | Penryn | SandyBridge | SandyBridge-IBRS | Skylake-Client | Skylake-Client-IBRS | Skylake-Client-noTSX-IBRS | Skylake-Server | Skylake-Server-IBRS | Skylake-Server-noTSX-IBRS | Westmere | Westmere-IBRS | athlon | core2duo | coreduo | host | kvm32 | kvm64 | max | pentium | pentium2 | pentium3 | phenom | qemu32 | qemu64>` ('default =' `kvm64`);;
+`reported-model`=`<486 | Broadwell | Broadwell-IBRS | Broadwell-noTSX | Broadwell-noTSX-IBRS | Cascadelake-Server | Cascadelake-Server-noTSX | Cascadelake-Server-v2 | Cascadelake-Server-v4 | Cascadelake-Server-v5 | Conroe | Cooperlake | Cooperlake-v2 | EPYC | EPYC-Genoa | EPYC-IBPB | EPYC-Milan | EPYC-Milan-v2 | EPYC-Rome | EPYC-Rome-v2 | EPYC-Rome-v3 | EPYC-Rome-v4 | EPYC-v3 | EPYC-v4 | GraniteRapids | Haswell | Haswell-IBRS | Haswell-noTSX | Haswell-noTSX-IBRS | Icelake-Client | Icelake-Client-noTSX | Icelake-Server | Icelake-Server-noTSX | Icelake-Server-v3 | Icelake-Server-v4 | Icelake-Server-v5 | Icelake-Server-v6 | IvyBridge | IvyBridge-IBRS | KnightsMill | Nehalem | Nehalem-IBRS | Opteron_G1 | Opteron_G2 | Opteron_G3 | Opteron_G4 | Opteron_G5 | Penryn | SandyBridge | SandyBridge-IBRS | SapphireRapids | SapphireRapids-v2 | Skylake-Client | Skylake-Client-IBRS | Skylake-Client-noTSX-IBRS | Skylake-Client-v4 | Skylake-Server | Skylake-Server-IBRS | Skylake-Server-noTSX-IBRS | Skylake-Server-v4 | Skylake-Server-v5 | Westmere | Westmere-IBRS | athlon | core2duo | coreduo | host | kvm32 | kvm64 | max | pentium | pentium2 | pentium3 | phenom | qemu32 | qemu64>` ('default =' `kvm64`);;
 
 CPU model and vendor to report to the guest. Must be a QEMU/KVM supported model. Only valid for custom CPU model definitions, default models will always report themselves to the guest OS.
 
@@ -155,7 +167,7 @@ Limit of CPU usage.
 +
 NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.
 
-`cpuunits`: `<integer> (2 - 262144)` ('default =' `cgroup v1: 1024, cgroup v2: 100`)::
+`cpuunits`: `<integer> (1 - 262144)` ('default =' `cgroup v1: 1024, cgroup v2: 100`)::
 
 CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.
 
@@ -165,11 +177,11 @@ Description for the VM. Shown in the web-interface VM's summary. This is saved a
 
 `efidisk0`: `[file=]<volume> [,efitype=<2m|4m>] [,format=<enum>] [,pre-enrolled-keys=<1|0>] [,size=<DiskSize>]` ::
 
-Configure a Disk for storing EFI vars. Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume. Note that SIZE_IN_GiB is ignored here and that the default EFI vars are copied to the volume instead.
+Configure a disk for storing EFI vars.
 
 `efitype`=`<2m | 4m>` ('default =' `2m`);;
 
-Size and type of the OVMF EFI vars. '4m' is newer and recommended, and required for Secure Boot. For backwards compatibility, '2m' is used if not otherwise specified.
+Size and type of the OVMF EFI vars. '4m' is newer and recommended, and required for Secure Boot. For backwards compatibility, '2m' is used if not otherwise specified. Ignored for VMs with arch=aarch64 (ARM).
 
 `file`=`<volume>` ;;
 
@@ -195,7 +207,7 @@ Freeze CPU at startup (use 'c' monitor command to start execution).
 
 Script that will be executed during various steps in the vms lifetime.
 
-`hostpci[n]`: `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,legacy-igd=<1|0>] [,mdev=<string>] [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,x-vga=<1|0>]` ::
+`hostpci[n]`: `[[host=]<HOSTPCIID[;HOSTPCIID2...]>] [,device-id=<hex id>] [,legacy-igd=<1|0>] [,mapping=<mapping-id>] [,mdev=<string>] [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,sub-device-id=<hex id>] [,sub-vendor-id=<hex id>] [,vendor-id=<hex id>] [,x-vga=<1|0>]` ::
 
 Map host PCI devices into guest.
 +
@@ -204,6 +216,10 @@ possible to migrate such machines - use with special care.
 +
 CAUTION: Experimental! User reported problems with this option.
 
+`device-id`=`<hex id>` ;;
+
+Override PCI device ID visible to guest
+
 `host`=`<HOSTPCIID[;HOSTPCIID2...]>` ;;
 
 Host PCI device pass through. The PCI ID of a host's PCI device or a list
@@ -212,11 +228,17 @@ of PCI virtual functions of the host. HOSTPCIID syntax is:
 'bus:dev.func' (hexadecimal numbers)
 +
 You can us the 'lspci' command to list existing PCI devices.
++
+Either this or the 'mapping' key must be set.
 
 `legacy-igd`=`<boolean>` ('default =' `0`);;
 
 Pass this device in legacy IGD mode, making it the primary and exclusive graphics device in the VM. Requires 'pc-i440fx' machine type and VGA set to 'none'.
 
+`mapping`=`<mapping-id>` ;;
+
+The ID of a cluster wide mapping. Either this or the default-key 'host' must be set.
+
 `mdev`=`<string>` ;;
 
 The type of mediated device to use.
@@ -235,13 +257,25 @@ Specify whether or not the device's ROM will be visible in the guest's memory ma
 
 Custom pci device rom filename (must be located in /usr/share/kvm/).
 
+`sub-device-id`=`<hex id>` ;;
+
+Override PCI subsystem device ID visible to guest
+
+`sub-vendor-id`=`<hex id>` ;;
+
+Override PCI subsystem vendor ID visible to guest
+
+`vendor-id`=`<hex id>` ;;
+
+Override PCI vendor ID visible to guest
+
 `x-vga`=`<boolean>` ('default =' `0`);;
 
 Enable vfio-vga device support.
 
 `hotplug`: `<string>` ('default =' `network,disk,usb`)::
 
-Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Using '1' as value is an alias for the default `network,disk,usb`.
+Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory', 'usb' and 'cloudinit'. Use '0' to disable hotplug completely. Using '1' as value is an alias for the default `network,disk,usb`. USB hotplugging is possible for guests with machine version >= 7.1 and ostype l26 or windows > 7.
 
 `hugepages`: `<1024 | 2 | any>` ::
 
@@ -249,7 +283,7 @@ Enable/disable hugepages memory.
 
 `ide[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
 
-Use volume as IDE hard disk or CD-ROM (n is 0 to 3). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
+Use volume as IDE hard disk or CD-ROM (n is 0 to 3).
 
 `aio`=`<io_uring | native | threads>` ;;
 
@@ -477,7 +511,7 @@ Use together with hugepages. If enabled, hugepages will not not be deleted after
 
 `keyboard`: `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ::
 
-Keyboard layout for VNC server. The default is read from the'/etc/pve/datacenter.cfg' configuration file. It should not be necessary to set it.
+Keyboard layout for VNC server. This option is generally not required and is often better handled from within the guest OS.
 
 `kvm`: `<boolean>` ('default =' `1`)::
 
@@ -491,13 +525,25 @@ Set the real time clock (RTC) to local time. This is enabled by default if the `
 
 Lock/unlock the VM.
 
-`machine`: `(pc|pc(-i440fx)?-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|q35|pc-q35-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|virt(?:-\d+(\.\d+)+)?(\+pve\d+)?)` ::
+`machine`: `[[type=]<machine type>] [,viommu=<intel|virtio>]` ::
+
+Specify the QEMU machine.
+
+`type`=`<machine type>` ;;
+
+Specifies the QEMU machine type.
 
-Specifies the Qemu machine type.
+`viommu`=`<intel | virtio>` ;;
 
-`memory`: `<integer> (16 - N)` ('default =' `512`)::
+Enable and set guest vIOMMU variant (Intel vIOMMU needs q35 to be set as machine type).
 
-Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
+`memory`: `[current=]<integer>` ::
+
+Memory properties.
+
+`current`=`<integer> (16 - N)` ('default =' `512`);;
+
+Current amount of online RAM for the VM in MiB. This is the maximum available memory when you use the balloon device.
 
 `migrate_downtime`: `<number> (0 - N)` ('default =' `0.1`)::
 
@@ -513,9 +559,7 @@ Set a name for the VM. Only used on the configuration web interface.
 
 `nameserver`: `<string>` ::
 
-cloud-init: Sets DNS server IP address for a container. Create will'
-           .' automatically use the setting from the host if neither searchdomain nor nameserver'
-           .' are set.
+cloud-init: Sets DNS server IP address for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
 
 `net[n]`: `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,mtu=<integer>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
 
@@ -556,7 +600,7 @@ Network Card Model. The 'virtio' model provides the best performance with very l
 
 Force MTU, for VirtIO only. Set to '1' to use the bridge MTU
 
-`queues`=`<integer> (0 - 16)` ;;
+`queues`=`<integer> (0 - 64)` ;;
 
 Number of packet queues to be used on the device.
 
@@ -615,9 +659,9 @@ wvista;; Microsoft Windows Vista
 win7;; Microsoft Windows 7
 win8;; Microsoft Windows 8/2012/2012r2
 win10;; Microsoft Windows 10/2016/2019
-win11;; Microsoft Windows 11/2022
+win11;; Microsoft Windows 11/2022/2025
 l24;; Linux 2.4 Kernel
-l26;; Linux 2.6 - 5.X Kernel
+l26;; Linux 2.6 - 6.X Kernel
 solaris;; Solaris/OpenSolaris/OpenIndiania kernel
 
 `parallel[n]`: `/dev/parport\d+|/dev/usb/lp\d+` ::
@@ -655,7 +699,7 @@ The file on the host to gather entropy from. In most cases '/dev/urandom' should
 
 `sata[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
 
-Use volume as SATA hard disk or CD-ROM (n is 0 to 5). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
+Use volume as SATA hard disk or CD-ROM (n is 0 to 5).
 
 `aio`=`<io_uring | native | threads>` ;;
 
@@ -827,9 +871,9 @@ Write error action.
 
 The drive's worldwide name, encoded as 16 bytes hex string, prefixed by '0x'.
 
-`scsi[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,ro=<1|0>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>] [,wwn=<wwn>]` ::
+`scsi[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,product=<product>] [,queues=<integer>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,ro=<1|0>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,ssd=<1|0>] [,trans=<none|lba|auto>] [,vendor=<vendor>] [,werror=<enum>] [,wwn=<wwn>]` ::
 
-Use volume as SCSI hard disk or CD-ROM (n is 0 to 30). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
+Use volume as SCSI hard disk or CD-ROM (n is 0 to 30).
 
 `aio`=`<io_uring | native | threads>` ;;
 
@@ -959,6 +1003,10 @@ Maximum unthrottled write pool in megabytes per second.
 
 The drive's media type.
 
+`product`=`<product>` ;;
+
+The drive's product name, up to 16 bytes long.
+
 `queues`=`<integer> (2 - N)` ;;
 
 Number of queues.
@@ -1011,6 +1059,10 @@ Whether to expose this drive as an SSD, rather than a rotational hard disk.
 
 Force disk geometry bios translation mode.
 
+`vendor`=`<vendor>` ;;
+
+The drive's vendor name, up to 8 bytes long.
+
 `werror`=`<enospc | ignore | report | stop>` ;;
 
 Write error action.
@@ -1025,9 +1077,7 @@ SCSI controller model
 
 `searchdomain`: `<string>` ::
 
-cloud-init: Sets DNS search domains for a container. Create will'
-           .' automatically use the setting from the host if neither searchdomain nor nameserver'
-           .' are set.
+cloud-init: Sets DNS search domains for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
 
 `serial[n]`: `(/dev/.+|socket)` ::
 
@@ -1130,7 +1180,7 @@ Enable/disable Template.
 
 `tpmstate0`: `[file=]<volume> [,size=<DiskSize>] [,version=<v1.2|v2.0>]` ::
 
-Configure a Disk for storing TPM state. Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume. Note that SIZE_IN_GiB is ignored here and that the default size of 4 MiB will always be used instead. The format is also fixed to 'raw'.
+Configure a Disk for storing TPM state. The format is fixed to 'raw'.
 
 `file`=`<volume>` ;;
 
@@ -1152,9 +1202,9 @@ Reference to unused volumes. This is used internally, and should not be modified
 
 The drive's backing volume.
 
-`usb[n]`: `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
+`usb[n]`: `[[host=]<HOSTUSBDEVICE|spice>] [,mapping=<mapping-id>] [,usb3=<1|0>]` ::
 
-Configure an USB device (n is 0 to 4).
+Configure an USB device (n is 0 to 4, for machine version >= 7.1 and ostype l26 or windows > 7, n can be up to 14).
 
 `host`=`<HOSTUSBDEVICE|spice>` ;;
 
@@ -1170,31 +1220,41 @@ NOTE: This option allows direct access to host hardware. So it is no longer poss
 machines - use with special care.
 +
 The value 'spice' can be used to add a usb redirection devices for spice.
++
+Either this or the 'mapping' key must be set.
+
+`mapping`=`<mapping-id>` ;;
+
+The ID of a cluster wide mapping. Either this or the default-key 'host' must be set.
 
 `usb3`=`<boolean>` ('default =' `0`);;
 
-Specifies whether if given host option is a USB3 device or port.
+Specifies whether if given host option is a USB3 device or port. For modern guests (machine version >= 7.1 and ostype l26 and windows > 7), this flag is irrelevant (all devices are plugged into a xhci controller).
 
 `vcpus`: `<integer> (1 - N)` ('default =' `0`)::
 
 Number of hotplugged vcpus.
 
-`vga`: `[[type=]<enum>] [,memory=<integer>]` ::
+`vga`: `[[type=]<enum>] [,clipboard=<vnc>] [,memory=<integer>]` ::
 
 Configure the VGA Hardware. If you want to use high resolution modes (>= 1280x1024x16) you may need to increase the vga memory option. Since QEMU 2.9 the default VGA display type is 'std' for all OS types besides some Windows versions (XP and older) which use 'cirrus'. The 'qxl' option enables the SPICE display server. For win* OS you can select how many independent displays you want, Linux guests can add displays them self.
 You can also run without any graphic card, using a serial device as terminal.
 
+`clipboard`=`<vnc>` ;;
+
+Enable a specific clipboard. If not set, depending on the display type the SPICE one will be added. Migration with VNC clipboard is not yet supported!
+
 `memory`=`<integer> (4 - 512)` ;;
 
 Sets the VGA memory (in MiB). Has no effect with serial display.
 
-`type`=`<cirrus | none | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | virtio | vmware>` ('default =' `std`);;
+`type`=`<cirrus | none | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | virtio | virtio-gl | vmware>` ('default =' `std`);;
 
 Select the VGA type.
 
 `virtio[n]`: `[file=]<volume> [,aio=<native|threads|io_uring>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,ro=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
-Use volume as VIRTIO hard disk (n is 0 to 15). Use the special syntax STORAGE_ID:SIZE_IN_GiB to allocate a new volume.
+Use volume as VIRTIO hard disk (n is 0 to 15).
 
 `aio`=`<io_uring | native | threads>` ;;
 
@@ -1371,7 +1431,7 @@ Write error action.
 The VM generation ID (vmgenid) device exposes a 128-bit integer value identifier to the guest OS. This allows to notify the guest operating system when the virtual machine is executed with a different configuration (e.g. snapshot execution or creation from a template). The guest operating system notices the change, and is then able to react as appropriate by marking its copies of distributed databases as dirty, re-initializing its random number generator, etc.
 Note that auto-creation only works when done through API/CLI create or update methods, but not when manually editing the config file.
 
-`vmstatestorage`: `<string>` ::
+`vmstatestorage`: `<storage ID>` ::
 
 Default storage for VM state volumes/files.