1 package PVE
::QemuServer
;
11 use File
::Copy
qw(copy);
24 use Storable
qw(dclone);
25 use Time
::HiRes
qw(gettimeofday);
29 use PVE
::Cluster
qw(cfs_register_file cfs_read_file cfs_write_file);
31 use PVE
::DataCenterConfig
;
32 use PVE
::Exception
qw(raise raise_param_exc);
33 use PVE
::GuestHelpers
qw(safe_string_ne safe_num_ne safe_boolean_ne);
35 use PVE
::JSONSchema
qw(get_standard_option parse_property_string);
38 use PVE
::RPCEnvironment
;
42 use PVE
::Tools
qw(run_command file_read_firstline file_get_contents dir_glob_foreach get_host_arch $IPV6RE);
46 use PVE
::QemuServer
::Helpers
qw(min_version config_aware_timeout);
47 use PVE
::QemuServer
::Cloudinit
;
48 use PVE
::QemuServer
::CGroup
;
49 use PVE
::QemuServer
::CPUConfig
qw(print_cpu_device get_cpu_options);
50 use PVE
::QemuServer
::Drive
qw(is_valid_drivename drive_is_cloudinit drive_is_cdrom parse_drive print_drive);
51 use PVE
::QemuServer
::Machine
;
52 use PVE
::QemuServer
::Memory
;
53 use PVE
::QemuServer
::Monitor
qw(mon_cmd);
54 use PVE
::QemuServer
::PCI
qw(print_pci_addr print_pcie_addr print_pcie_root_port parse_hostpci);
55 use PVE
::QemuServer
::USB
qw(parse_usb_device);
59 require PVE
::Network
::SDN
::Zones
;
63 my $EDK2_FW_BASE = '/usr/share/pve-edk2-firmware/';
66 "$EDK2_FW_BASE/OVMF_CODE.fd",
67 "$EDK2_FW_BASE/OVMF_VARS.fd"
70 "$EDK2_FW_BASE/AAVMF_CODE.fd",
71 "$EDK2_FW_BASE/AAVMF_VARS.fd"
75 my $cpuinfo = PVE
::ProcFSTools
::read_cpuinfo
();
77 # Note about locking: we use flock on the config file protect
78 # against concurent actions.
79 # Aditionaly, we have a 'lock' setting in the config file. This
80 # can be set to 'migrate', 'backup', 'snapshot' or 'rollback'. Most actions are not
81 # allowed when such lock is set. But you can ignore this kind of
82 # lock with the --skiplock flag.
84 cfs_register_file
('/qemu-server/',
88 PVE
::JSONSchema
::register_standard_option
('pve-qm-stateuri', {
89 description
=> "Some command save/restore state from this location.",
95 PVE
::JSONSchema
::register_standard_option
('pve-qemu-machine', {
96 description
=> "Specifies the Qemu machine type.",
98 pattern
=> '(pc|pc(-i440fx)?-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|q35|pc-q35-\d+(\.\d+)+(\+pve\d+)?(\.pxe)?|virt(?:-\d+(\.\d+)+)?(\+pve\d+)?)',
105 my ($map, $source) = @_;
107 return $source if !defined($map);
109 return $map->{entries
}->{$source}
110 if $map->{entries
} && defined($map->{entries
}->{$source});
112 return $map->{default} if $map->{default};
114 # identity (fallback)
118 PVE
::JSONSchema
::register_standard_option
('pve-targetstorage', {
119 description
=> "Mapping from source to target storages. Providing only a single storage ID maps all source storages to that storage. Providing the special value '1' will map each source storage to itself.",
121 format
=> 'storagepair-list',
125 #no warnings 'redefine';
129 $nodename_cache //= PVE
::INotify
::nodename
();
130 return $nodename_cache;
137 enum
=> [qw(i6300esb ib700)],
138 description
=> "Watchdog type to emulate.",
139 default => 'i6300esb',
144 enum
=> [qw(reset shutdown poweroff pause debug none)],
145 description
=> "The action to perform if after activation the guest fails to poll the watchdog in time.",
149 PVE
::JSONSchema
::register_format
('pve-qm-watchdog', $watchdog_fmt);
153 description
=> "Enable/disable Qemu GuestAgent.",
158 fstrim_cloned_disks
=> {
159 description
=> "Run fstrim after moving a disk or migrating the VM.",
165 description
=> "Select the agent type",
169 enum
=> [qw(virtio isa)],
175 description
=> "Select the VGA type.",
180 enum
=> [qw(cirrus qxl qxl2 qxl3 qxl4 none serial0 serial1 serial2 serial3 std virtio vmware)],
183 description
=> "Sets the VGA memory (in MiB). Has no effect with serial display.",
195 description
=> "The size of the file in MB.",
199 pattern
=> '[a-zA-Z0-9\-]+',
201 format_description
=> 'string',
202 description
=> "The name of the file. Will be prefixed with 'pve-shm-'. Default is the VMID. Will be deleted when the VM is stopped.",
209 enum
=> [qw(ich9-intel-hda intel-hda AC97)],
210 description
=> "Configure an audio device."
214 enum
=> ['spice', 'none'],
217 description
=> "Driver backend for the audio device."
221 my $spice_enhancements_fmt = {
226 description
=> "Enable folder sharing via SPICE. Needs Spice-WebDAV daemon installed in the VM."
230 enum
=> ['off', 'all', 'filter'],
233 description
=> "Enable video streaming. Uses compression for detected video streams."
240 enum
=> ['/dev/urandom', '/dev/random', '/dev/hwrng'],
242 description
=> "The file on the host to gather entropy from. In most"
243 . " cases /dev/urandom should be preferred over /dev/random"
244 . " to avoid entropy-starvation issues on the host. Using"
245 . " urandom does *not* decrease security in any meaningful"
246 . " way, as it's still seeded from real entropy, and the"
247 . " bytes provided will most likely be mixed with real"
248 . " entropy on the guest as well. /dev/hwrng can be used"
249 . " to pass through a hardware RNG from the host.",
253 description
=> "Maximum bytes of entropy injected into the guest every"
254 . " 'period' milliseconds. Prefer a lower value when using"
255 . " /dev/random as source. Use 0 to disable limiting"
256 . " (potentially dangerous!).",
259 # default is 1 KiB/s, provides enough entropy to the guest to avoid
260 # boot-starvation issues (e.g. systemd etc...) while allowing no chance
261 # of overwhelming the host, provided we're reading from /dev/urandom
266 description
=> "Every 'period' milliseconds the entropy-injection quota"
267 . " is reset, allowing the guest to retrieve another"
268 . " 'max_bytes' of entropy.",
278 description
=> "Specifies whether a VM will be started during system bootup.",
284 description
=> "Automatic restart after crash (currently ignored).",
289 type
=> 'string', format
=> 'pve-hotplug-features',
290 description
=> "Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.",
291 default => 'network,disk,usb',
296 description
=> "Allow reboot. If set to '0' the VM exit on reboot.",
302 description
=> "Lock/unlock the VM.",
303 enum
=> [qw(backup clone create migrate rollback snapshot snapshot-delete suspending suspended)],
308 description
=> "Limit of CPU usage.",
309 verbose_description
=> "Limit of CPU usage.\n\nNOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.",
317 description
=> "CPU weight for a VM.",
318 verbose_description
=> "CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.",
326 description
=> "Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.",
333 description
=> "Amount of target RAM for the VM in MB. Using zero disables the ballon driver.",
339 description
=> "Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.",
347 description
=> "Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.cfg' configuration file.".
348 "It should not be necessary to set it.",
349 enum
=> PVE
::Tools
::kvmkeymaplist
(),
354 type
=> 'string', format
=> 'dns-name',
355 description
=> "Set a name for the VM. Only used on the configuration web interface.",
360 description
=> "SCSI controller model",
361 enum
=> [qw(lsi lsi53c810 virtio-scsi-pci virtio-scsi-single megasas pvscsi)],
367 description
=> "Description for the VM. Only used on the configuration web interface. This is saved as comment inside the configuration file.",
372 enum
=> [qw(other wxp w2k w2k3 w2k8 wvista win7 win8 win10 l24 l26 solaris)],
373 description
=> "Specify guest operating system.",
374 verbose_description
=> <<EODESC,
375 Specify guest operating system. This is used to enable special
376 optimization/features for specific operating systems:
379 other;; unspecified OS
380 wxp;; Microsoft Windows XP
381 w2k;; Microsoft Windows 2000
382 w2k3;; Microsoft Windows 2003
383 w2k8;; Microsoft Windows 2008
384 wvista;; Microsoft Windows Vista
385 win7;; Microsoft Windows 7
386 win8;; Microsoft Windows 8/2012/2012r2
387 win10;; Microsoft Windows 10/2016/2019
388 l24;; Linux 2.4 Kernel
389 l26;; Linux 2.6 - 5.X Kernel
390 solaris;; Solaris/OpenSolaris/OpenIndiania kernel
395 type
=> 'string', format
=> 'pve-qm-boot',
396 description
=> "Specify guest boot order. Use with 'order=', usage with"
397 . " no key or 'legacy=' is deprecated.",
401 type
=> 'string', format
=> 'pve-qm-bootdisk',
402 description
=> "Enable booting from specified disk. Deprecated: Use 'boot: order=foo;bar' instead.",
403 pattern
=> '(ide|sata|scsi|virtio)\d+',
408 description
=> "The number of CPUs. Please use option -sockets instead.",
415 description
=> "The number of CPU sockets.",
422 description
=> "The number of cores per socket.",
429 description
=> "Enable/disable NUMA.",
435 description
=> "Enable/disable hugepages memory.",
436 enum
=> [qw(any 2 1024)],
442 description
=> "Use together with hugepages. If enabled, hugepages will not not be deleted"
443 ." after VM shutdown and can be used for subsequent starts.",
448 description
=> "Number of hotplugged vcpus.",
455 description
=> "Enable/disable ACPI.",
460 description
=> "Enable/disable Qemu GuestAgent and its properties.",
462 format
=> $agent_fmt,
467 description
=> "Enable/disable KVM hardware virtualization.",
473 description
=> "Enable/disable time drift fix.",
479 description
=> "Set the real time clock to local time. This is enabled by default if ostype"
480 ." indicates a Microsoft OS.",
485 description
=> "Freeze CPU at startup (use 'c' monitor command to start execution).",
489 type
=> 'string', format
=> $vga_fmt,
490 description
=> "Configure the VGA hardware.",
491 verbose_description
=> "Configure the VGA Hardware. If you want to use high resolution"
492 ." modes (>= 1280x1024x16) you may need to increase the vga memory option. Since QEMU"
493 ." 2.9 the default VGA display type is 'std' for all OS types besides some Windows"
494 ." versions (XP and older) which use 'cirrus'. The 'qxl' option enables the SPICE"
495 ." display server. For win* OS you can select how many independent displays you want,"
496 ." Linux guests can add displays them self.\nYou can also run without any graphic card,"
497 ." using a serial device as terminal.",
501 type
=> 'string', format
=> 'pve-qm-watchdog',
502 description
=> "Create a virtual hardware watchdog device.",
503 verbose_description
=> "Create a virtual hardware watchdog device. Once enabled (by a guest"
504 ." action), the watchdog must be periodically polled by an agent inside the guest or"
505 ." else the watchdog will reset the guest (or execute the respective action specified)",
510 typetext
=> "(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)",
511 description
=> "Set the initial date of the real time clock. Valid format for date are:"
512 ."'now' or '2006-06-17T16:01:21' or '2006-06-17'.",
513 pattern
=> '(now|\d{4}-\d{1,2}-\d{1,2}(T\d{1,2}:\d{1,2}:\d{1,2})?)',
516 startup
=> get_standard_option
('pve-startup-order'),
520 description
=> "Enable/disable Template.",
526 description
=> "Arbitrary arguments passed to kvm.",
527 verbose_description
=> <<EODESCR,
528 Arbitrary arguments passed to kvm, for example:
530 args: -no-reboot -no-hpet
532 NOTE: this option is for experts only.
539 description
=> "Enable/disable the USB tablet device.",
540 verbose_description
=> "Enable/disable the USB tablet device. This device is usually needed"
541 ." to allow absolute mouse positioning with VNC. Else the mouse runs out of sync with"
542 ." normal VNC clients. If you're running lots of console-only guests on one host, you"
543 ." may consider disabling this to save some context switches. This is turned off by"
544 ." default if you use spice (`qm set <vmid> --vga qxl`).",
549 description
=> "Set maximum speed (in MB/s) for migrations. Value 0 is no limit.",
553 migrate_downtime
=> {
556 description
=> "Set maximum tolerated downtime (in seconds) for migrations.",
562 type
=> 'string', format
=> 'pve-qm-ide',
563 typetext
=> '<volume>',
564 description
=> "This is an alias for option -ide2",
568 description
=> "Emulated CPU type.",
570 format
=> 'pve-vm-cpu-conf',
572 parent
=> get_standard_option
('pve-snapshot-name', {
574 description
=> "Parent snapshot name. This is used internally, and should not be modified.",
578 description
=> "Timestamp for snapshots.",
584 type
=> 'string', format
=> 'pve-volume-id',
585 description
=> "Reference to a volume which stores the VM state. This is used internally"
588 vmstatestorage
=> get_standard_option
('pve-storage-id', {
589 description
=> "Default storage for VM state volumes/files.",
592 runningmachine
=> get_standard_option
('pve-qemu-machine', {
593 description
=> "Specifies the QEMU machine type of the running vm. This is used internally"
597 description
=> "Specifies the QEMU '-cpu' parameter of the running vm. This is used"
598 ." internally for snapshots.",
601 pattern
=> $PVE::QemuServer
::CPUConfig
::qemu_cmdline_cpu_re
,
602 format_description
=> 'QEMU -cpu parameter'
604 machine
=> get_standard_option
('pve-qemu-machine'),
606 description
=> "Virtual processor architecture. Defaults to the host.",
609 enum
=> [qw(x86_64 aarch64)],
612 description
=> "Specify SMBIOS type 1 fields.",
613 type
=> 'string', format
=> 'pve-qm-smbios1',
620 description
=> "Sets the protection flag of the VM. This will disable the remove VM and"
621 ." remove disk operations.",
627 enum
=> [ qw(seabios ovmf) ],
628 description
=> "Select BIOS implementation.",
629 default => 'seabios',
633 pattern
=> '(?:[a-fA-F0-9]{8}(?:-[a-fA-F0-9]{4}){3}-[a-fA-F0-9]{12}|[01])',
634 format_description
=> 'UUID',
635 description
=> "Set VM Generation ID. Use '1' to autogenerate on create or update, pass '0'"
636 ." to disable explicitly.",
637 verbose_description
=> "The VM generation ID (vmgenid) device exposes a 128-bit integer"
638 ." value identifier to the guest OS. This allows to notify the guest operating system"
639 ." when the virtual machine is executed with a different configuration (e.g. snapshot"
640 ." execution or creation from a template). The guest operating system notices the"
641 ." change, and is then able to react as appropriate by marking its copies of"
642 ." distributed databases as dirty, re-initializing its random number generator, etc.\n"
643 ."Note that auto-creation only works when done through API/CLI create or update methods"
644 .", but not when manually editing the config file.",
645 default => "1 (autogenerated)",
650 format
=> 'pve-volume-id',
652 description
=> "Script that will be executed during various steps in the vms lifetime.",
656 format
=> $ivshmem_fmt,
657 description
=> "Inter-VM shared memory. Useful for direct communication between VMs, or to"
663 format
=> $audio_fmt,
664 description
=> "Configure a audio device, useful in combination with QXL/Spice.",
667 spice_enhancements
=> {
669 format
=> $spice_enhancements_fmt,
670 description
=> "Configure additional enhancements for SPICE.",
674 type
=> 'string', format
=> 'pve-tag-list',
675 description
=> 'Tags of the VM. This is only meta information.',
681 description
=> "Configure a VirtIO-based Random Number Generator.",
690 description
=> 'Specify a custom file containing all meta data passed to the VM via"
691 ." cloud-init. This is provider specific meaning configdrive2 and nocloud differ.',
692 format
=> 'pve-volume-id',
693 format_description
=> 'volume',
698 description
=> 'Specify a custom file containing all network data passed to the VM via'
700 format
=> 'pve-volume-id',
701 format_description
=> 'volume',
706 description
=> 'Specify a custom file containing all user data passed to the VM via'
708 format
=> 'pve-volume-id',
709 format_description
=> 'volume',
712 PVE
::JSONSchema
::register_format
('pve-qm-cicustom', $cicustom_fmt);
714 my $confdesc_cloudinit = {
718 description
=> 'Specifies the cloud-init configuration format. The default depends on the'
719 .' configured operating system type (`ostype`. We use the `nocloud` format for Linux,'
720 .' and `configdrive2` for windows.',
721 enum
=> ['configdrive2', 'nocloud', 'opennebula'],
726 description
=> "cloud-init: User name to change ssh keys and password for instead of the"
727 ." image's configured default user.",
732 description
=> 'cloud-init: Password to assign the user. Using this is generally not'
733 .' recommended. Use ssh keys instead. Also note that older cloud-init versions do not'
734 .' support hashed passwords.',
739 description
=> 'cloud-init: Specify custom files to replace the automatically generated'
741 format
=> 'pve-qm-cicustom',
746 description
=> "cloud-init: Sets DNS search domains for a container. Create will'
747 .' automatically use the setting from the host if neither searchdomain nor nameserver'
752 type
=> 'string', format
=> 'address-list',
753 description
=> "cloud-init: Sets DNS server IP address for a container. Create will'
754 .' automatically use the setting from the host if neither searchdomain nor nameserver'
760 format
=> 'urlencoded',
761 description
=> "cloud-init: Setup public SSH keys (one key per line, OpenSSH format).",
765 # what about other qemu settings ?
767 #machine => 'string',
780 ##soundhw => 'string',
782 while (my ($k, $v) = each %$confdesc) {
783 PVE
::JSONSchema
::register_standard_option
("pve-qm-$k", $v);
786 my $MAX_USB_DEVICES = 5;
788 my $MAX_SERIAL_PORTS = 4;
789 my $MAX_PARALLEL_PORTS = 3;
795 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
796 description
=> "CPUs accessing this NUMA node.",
797 format_description
=> "id[-id];...",
801 description
=> "Amount of memory this NUMA node provides.",
806 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
807 description
=> "Host NUMA nodes to use.",
808 format_description
=> "id[-id];...",
813 enum
=> [qw(preferred bind interleave)],
814 description
=> "NUMA allocation policy.",
818 PVE
::JSONSchema
::register_format
('pve-qm-numanode', $numa_fmt);
821 type
=> 'string', format
=> $numa_fmt,
822 description
=> "NUMA topology.",
824 PVE
::JSONSchema
::register_standard_option
("pve-qm-numanode", $numadesc);
826 for (my $i = 0; $i < $MAX_NUMA; $i++) {
827 $confdesc->{"numa$i"} = $numadesc;
830 my $nic_model_list = ['rtl8139', 'ne2k_pci', 'e1000', 'pcnet', 'virtio',
831 'ne2k_isa', 'i82551', 'i82557b', 'i82559er', 'vmxnet3',
832 'e1000-82540em', 'e1000-82544gc', 'e1000-82545em'];
833 my $nic_model_list_txt = join(' ', sort @$nic_model_list);
835 my $net_fmt_bridge_descr = <<__EOD__;
836 Bridge to attach the network device to. The Proxmox VE standard bridge
839 If you do not specify a bridge, we create a kvm user (NATed) network
840 device, which provides DHCP and DNS services. The following addresses
847 The DHCP server assign addresses to the guest starting from 10.0.2.15.
851 macaddr
=> get_standard_option
('mac-addr', {
852 description
=> "MAC address. That address must be unique withing your network. This is"
853 ." automatically generated if not specified.",
857 description
=> "Network Card Model. The 'virtio' model provides the best performance with"
858 ." very low CPU overhead. If your guest does not support this driver, it is usually"
859 ." best to use 'e1000'.",
860 enum
=> $nic_model_list,
863 (map { $_ => { keyAlias
=> 'model', alias
=> 'macaddr' }} @$nic_model_list),
866 description
=> $net_fmt_bridge_descr,
867 format_description
=> 'bridge',
868 pattern
=> '[-_.\w\d]+',
873 minimum
=> 0, maximum
=> 16,
874 description
=> 'Number of packet queues to be used on the device.',
880 description
=> "Rate limit in mbps (megabytes per second) as floating point number.",
885 minimum
=> 1, maximum
=> 4094,
886 description
=> 'VLAN tag to apply to packets on this interface.',
891 pattern
=> qr/\d+(?:-\d+)?(?:;\d+(?:-\d+)?)*/,
892 description
=> 'VLAN trunks to pass through this interface.',
893 format_description
=> 'vlanid[;vlanid...]',
898 description
=> 'Whether this interface should be protected by the firewall.',
903 description
=> 'Whether this interface should be disconnected (like pulling the plug).',
908 minimum
=> 1, maximum
=> 65520,
909 description
=> "Force MTU, for VirtIO only. Set to '1' to use the bridge MTU",
916 type
=> 'string', format
=> $net_fmt,
917 description
=> "Specify network devices.",
920 PVE
::JSONSchema
::register_standard_option
("pve-qm-net", $netdesc);
925 format
=> 'pve-ipv4-config',
926 format_description
=> 'IPv4Format/CIDR',
927 description
=> 'IPv4 address in CIDR format.',
934 format_description
=> 'GatewayIPv4',
935 description
=> 'Default gateway for IPv4 traffic.',
941 format
=> 'pve-ipv6-config',
942 format_description
=> 'IPv6Format/CIDR',
943 description
=> 'IPv6 address in CIDR format.',
950 format_description
=> 'GatewayIPv6',
951 description
=> 'Default gateway for IPv6 traffic.',
956 PVE
::JSONSchema
::register_format
('pve-qm-ipconfig', $ipconfig_fmt);
959 type
=> 'string', format
=> 'pve-qm-ipconfig',
960 description
=> <<'EODESCR',
961 cloud-init: Specify IP addresses and gateways for the corresponding interface.
963 IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
965 The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit
966 gateway should be provided.
967 For IPv6 the special string 'auto' can be used to use stateless autoconfiguration.
969 If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using
973 PVE
::JSONSchema
::register_standard_option
("pve-qm-ipconfig", $netdesc);
975 for (my $i = 0; $i < $MAX_NETS; $i++) {
976 $confdesc->{"net$i"} = $netdesc;
977 $confdesc_cloudinit->{"ipconfig$i"} = $ipconfigdesc;
980 foreach my $key (keys %$confdesc_cloudinit) {
981 $confdesc->{$key} = $confdesc_cloudinit->{$key};
984 PVE
::JSONSchema
::register_format
('pve-volume-id-or-qm-path', \
&verify_volume_id_or_qm_path
);
985 sub verify_volume_id_or_qm_path
{
986 my ($volid, $noerr) = @_;
988 if ($volid eq 'none' || $volid eq 'cdrom' || $volid =~ m
|^/|) {
992 # if its neither 'none' nor 'cdrom' nor a path, check if its a volume-id
993 $volid = eval { PVE
::JSONSchema
::check_format
('pve-volume-id', $volid, '') };
1004 type
=> 'string', format
=> 'pve-qm-usb-device',
1005 format_description
=> 'HOSTUSBDEVICE|spice',
1006 description
=> <<EODESCR,
1007 The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
1009 'bus-port(.port)*' (decimal numbers) or
1010 'vendor_id:product_id' (hexadeciaml numbers) or
1013 You can use the 'lsusb -t' command to list existing usb devices.
1015 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
1016 machines - use with special care.
1018 The value 'spice' can be used to add a usb redirection devices for spice.
1024 description
=> "Specifies whether if given host option is a USB3 device or port.",
1031 type
=> 'string', format
=> $usb_fmt,
1032 description
=> "Configure an USB device (n is 0 to 4).",
1034 PVE
::JSONSchema
::register_standard_option
("pve-qm-usb", $usbdesc);
1039 pattern
=> '(/dev/.+|socket)',
1040 description
=> "Create a serial device inside the VM (n is 0 to 3)",
1041 verbose_description
=> <<EODESCR,
1042 Create a serial device inside the VM (n is 0 to 3), and pass through a
1043 host serial device (i.e. /dev/ttyS0), or create a unix socket on the
1044 host side (use 'qm terminal' to open a terminal connection).
1046 NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines -
1047 use with special care.
1049 CAUTION: Experimental! User reported problems with this option.
1056 pattern
=> '/dev/parport\d+|/dev/usb/lp\d+',
1057 description
=> "Map host parallel devices (n is 0 to 2).",
1058 verbose_description
=> <<EODESCR,
1059 Map host parallel devices (n is 0 to 2).
1061 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such
1062 machines - use with special care.
1064 CAUTION: Experimental! User reported problems with this option.
1068 for (my $i = 0; $i < $MAX_PARALLEL_PORTS; $i++) {
1069 $confdesc->{"parallel$i"} = $paralleldesc;
1072 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
1073 $confdesc->{"serial$i"} = $serialdesc;
1076 for (my $i = 0; $i < $PVE::QemuServer
::PCI
::MAX_HOSTPCI_DEVICES
; $i++) {
1077 $confdesc->{"hostpci$i"} = $PVE::QemuServer
::PCI
::hostpcidesc
;
1080 for my $key (keys %{$PVE::QemuServer
::Drive
::drivedesc_hash
}) {
1081 $confdesc->{$key} = $PVE::QemuServer
::Drive
::drivedesc_hash-
>{$key};
1084 for (my $i = 0; $i < $MAX_USB_DEVICES; $i++) {
1085 $confdesc->{"usb$i"} = $usbdesc;
1093 description
=> "Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n)."
1094 . " Deprecated, use 'order=' instead.",
1095 pattern
=> '[acdn]{1,4}',
1096 format_description
=> "[acdn]{1,4}",
1098 # note: this is also the fallback if boot: is not given at all
1104 format
=> 'pve-qm-bootdev-list',
1105 format_description
=> "device[;device...]",
1106 description
=> <<EODESC,
1107 The guest will attempt to boot from devices in the order they appear here.
1109 Disks, optical drives and passed-through storage USB devices will be directly
1110 booted from, NICs will load PXE, and PCIe devices will either behave like disks
1111 (e.g. NVMe) or load an option ROM (e.g. RAID controller, hardware NIC).
1113 Note that only devices in this list will be marked as bootable and thus loaded
1114 by the guest firmware (BIOS/UEFI). If you require multiple disks for booting
1115 (e.g. software-raid), you need to specify all of them here.
1117 Overrides the deprecated 'legacy=[acdn]*' value when given.
1121 PVE
::JSONSchema
::register_format
('pve-qm-boot', $boot_fmt);
1123 PVE
::JSONSchema
::register_format
('pve-qm-bootdev', \
&verify_bootdev
);
1124 sub verify_bootdev
{
1125 my ($dev, $noerr) = @_;
1127 return $dev if PVE
::QemuServer
::Drive
::is_valid_drivename
($dev) && $dev !~ m/^efidisk/;
1131 return 0 if $dev !~ m/^$base\d+$/;
1132 return 0 if !$confdesc->{$dev};
1136 return $dev if $check->("net");
1137 return $dev if $check->("usb");
1138 return $dev if $check->("hostpci");
1141 die "invalid boot device '$dev'\n";
1144 sub print_bootorder
{
1146 return "" if !@$devs;
1147 my $data = { order
=> join(';', @$devs) };
1148 return PVE
::JSONSchema
::print_property_string
($data, $boot_fmt);
1151 my $kvm_api_version = 0;
1154 return $kvm_api_version if $kvm_api_version;
1156 open my $fh, '<', '/dev/kvm' or return;
1158 # 0xae00 => KVM_GET_API_VERSION
1159 $kvm_api_version = ioctl($fh, 0xae00, 0);
1162 return $kvm_api_version;
1165 my $kvm_user_version = {};
1168 sub kvm_user_version
{
1171 $binary //= get_command_for_arch
(get_host_arch
()); # get the native arch by default
1172 my $st = stat($binary);
1174 my $cachedmtime = $kvm_mtime->{$binary} // -1;
1175 return $kvm_user_version->{$binary} if $kvm_user_version->{$binary} &&
1176 $cachedmtime == $st->mtime;
1178 $kvm_user_version->{$binary} = 'unknown';
1179 $kvm_mtime->{$binary} = $st->mtime;
1183 if ($line =~ m/^QEMU( PC)? emulator version (\d+\.\d+(\.\d+)?)(\.\d+)?[,\s]/) {
1184 $kvm_user_version->{$binary} = $2;
1188 eval { run_command
([$binary, '--version'], outfunc
=> $code); };
1191 return $kvm_user_version->{$binary};
1194 my sub extract_version
{
1195 my ($machine_type, $version) = @_;
1196 $version = kvm_user_version
() if !defined($version);
1197 PVE
::QemuServer
::Machine
::extract_version
($machine_type, $version)
1200 sub kernel_has_vhost_net
{
1201 return -c
'/dev/vhost-net';
1206 return defined($confdesc->{$key});
1210 sub get_cdrom_path
{
1212 return $cdrom_path if $cdrom_path;
1214 return $cdrom_path = "/dev/cdrom" if -l
"/dev/cdrom";
1215 return $cdrom_path = "/dev/cdrom1" if -l
"/dev/cdrom1";
1216 return $cdrom_path = "/dev/cdrom2" if -l
"/dev/cdrom2";
1220 my ($storecfg, $vmid, $cdrom) = @_;
1222 if ($cdrom eq 'cdrom') {
1223 return get_cdrom_path
();
1224 } elsif ($cdrom eq 'none') {
1226 } elsif ($cdrom =~ m
|^/|) {
1229 return PVE
::Storage
::path
($storecfg, $cdrom);
1233 # try to convert old style file names to volume IDs
1234 sub filename_to_volume_id
{
1235 my ($vmid, $file, $media) = @_;
1237 if (!($file eq 'none' || $file eq 'cdrom' ||
1238 $file =~ m
|^/dev/.+| || $file =~ m/^([^:]+):(.+)$/)) {
1240 return if $file =~ m
|/|;
1242 if ($media && $media eq 'cdrom') {
1243 $file = "local:iso/$file";
1245 $file = "local:$vmid/$file";
1252 sub verify_media_type
{
1253 my ($opt, $vtype, $media) = @_;
1258 if ($media eq 'disk') {
1260 } elsif ($media eq 'cdrom') {
1263 die "internal error";
1266 return if ($vtype eq $etype);
1268 raise_param_exc
({ $opt => "unexpected media type ($vtype != $etype)" });
1271 sub cleanup_drive_path
{
1272 my ($opt, $storecfg, $drive) = @_;
1274 # try to convert filesystem paths to volume IDs
1276 if (($drive->{file
} !~ m/^(cdrom|none)$/) &&
1277 ($drive->{file
} !~ m
|^/dev/.+|) &&
1278 ($drive->{file
} !~ m/^([^:]+):(.+)$/) &&
1279 ($drive->{file
} !~ m/^\d+$/)) {
1280 my ($vtype, $volid) = PVE
::Storage
::path_to_volume_id
($storecfg, $drive->{file
});
1281 raise_param_exc
({ $opt => "unable to associate path '$drive->{file}' to any storage"})
1283 $drive->{media
} = 'cdrom' if !$drive->{media
} && $vtype eq 'iso';
1284 verify_media_type
($opt, $vtype, $drive->{media
});
1285 $drive->{file
} = $volid;
1288 $drive->{media
} = 'cdrom' if !$drive->{media
} && $drive->{file
} =~ m/^(cdrom|none)$/;
1291 sub parse_hotplug_features
{
1296 return $res if $data eq '0';
1298 $data = $confdesc->{hotplug
}->{default} if $data eq '1';
1300 foreach my $feature (PVE
::Tools
::split_list
($data)) {
1301 if ($feature =~ m/^(network|disk|cpu|memory|usb)$/) {
1304 die "invalid hotplug feature '$feature'\n";
1310 PVE
::JSONSchema
::register_format
('pve-hotplug-features', \
&pve_verify_hotplug_features
);
1311 sub pve_verify_hotplug_features
{
1312 my ($value, $noerr) = @_;
1314 return $value if parse_hotplug_features
($value);
1318 die "unable to parse hotplug option\n";
1322 my($fh, $noerr) = @_;
1325 my $SG_GET_VERSION_NUM = 0x2282;
1327 my $versionbuf = "\x00" x
8;
1328 my $ret = ioctl($fh, $SG_GET_VERSION_NUM, $versionbuf);
1330 die "scsi ioctl SG_GET_VERSION_NUM failoed - $!\n" if !$noerr;
1333 my $version = unpack("I", $versionbuf);
1334 if ($version < 30000) {
1335 die "scsi generic interface too old\n" if !$noerr;
1339 my $buf = "\x00" x
36;
1340 my $sensebuf = "\x00" x
8;
1341 my $cmd = pack("C x3 C x1", 0x12, 36);
1343 # see /usr/include/scsi/sg.h
1344 my $sg_io_hdr_t = "i i C C s I P P P I I i P C C C C S S i I I";
1346 my $packet = pack($sg_io_hdr_t, ord('S'), -3, length($cmd),
1347 length($sensebuf), 0, length($buf), $buf,
1348 $cmd, $sensebuf, 6000);
1350 $ret = ioctl($fh, $SG_IO, $packet);
1352 die "scsi ioctl SG_IO failed - $!\n" if !$noerr;
1356 my @res = unpack($sg_io_hdr_t, $packet);
1357 if ($res[17] || $res[18]) {
1358 die "scsi ioctl SG_IO status error - $!\n" if !$noerr;
1363 (my $byte0, my $byte1, $res->{vendor
},
1364 $res->{product
}, $res->{revision
}) = unpack("C C x6 A8 A16 A4", $buf);
1366 $res->{removable
} = $byte1 & 128 ?
1 : 0;
1367 $res->{type
} = $byte0 & 31;
1375 my $fh = IO
::File-
>new("+<$path") || return;
1376 my $res = scsi_inquiry
($fh, 1);
1382 sub print_tabletdevice_full
{
1383 my ($conf, $arch) = @_;
1385 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
1387 # we use uhci for old VMs because tablet driver was buggy in older qemu
1389 if (PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf) || $arch eq 'aarch64') {
1395 return "usb-tablet,id=tablet,bus=$usbbus.0,port=1";
1398 sub print_keyboarddevice_full
{
1399 my ($conf, $arch, $machine) = @_;
1401 return if $arch ne 'aarch64';
1403 return "usb-kbd,id=keyboard,bus=ehci.0,port=2";
1406 sub print_drivedevice_full
{
1407 my ($storecfg, $conf, $vmid, $drive, $bridges, $arch, $machine_type) = @_;
1412 my $drive_id = "$drive->{interface}$drive->{index}";
1413 if ($drive->{interface
} eq 'virtio') {
1414 my $pciaddr = print_pci_addr
("$drive_id", $bridges, $arch, $machine_type);
1415 $device = "virtio-blk-pci,drive=drive-$drive_id,id=${drive_id}${pciaddr}";
1416 $device .= ",iothread=iothread-$drive_id" if $drive->{iothread
};
1417 } elsif ($drive->{interface
} eq 'scsi') {
1419 my ($maxdev, $controller, $controller_prefix) = scsihw_infos
($conf, $drive);
1420 my $unit = $drive->{index} % $maxdev;
1421 my $devicetype = 'hd';
1423 if (drive_is_cdrom
($drive)) {
1426 if ($drive->{file
} =~ m
|^/|) {
1427 $path = $drive->{file
};
1428 if (my $info = path_is_scsi
($path)) {
1429 if ($info->{type
} == 0 && $drive->{scsiblock
}) {
1430 $devicetype = 'block';
1431 } elsif ($info->{type
} == 1) { # tape
1432 $devicetype = 'generic';
1436 $path = PVE
::Storage
::path
($storecfg, $drive->{file
});
1439 # for compatibility only, we prefer scsi-hd (#2408, #2355, #2380)
1440 my $version = extract_version
($machine_type, kvm_user_version
());
1441 if ($path =~ m/^iscsi\:\/\
// &&
1442 !min_version
($version, 4, 1)) {
1443 $devicetype = 'generic';
1447 if (!$conf->{scsihw
} || ($conf->{scsihw
} =~ m/^lsi/)){
1448 $device = "scsi-$devicetype,bus=$controller_prefix$controller.0,scsi-id=$unit";
1450 $device = "scsi-$devicetype,bus=$controller_prefix$controller.0,channel=0,scsi-id=0"
1451 .",lun=$drive->{index}";
1453 $device .= ",drive=drive-$drive_id,id=$drive_id";
1455 if ($drive->{ssd
} && ($devicetype eq 'block' || $devicetype eq 'hd')) {
1456 $device .= ",rotation_rate=1";
1458 $device .= ",wwn=$drive->{wwn}" if $drive->{wwn
};
1460 } elsif ($drive->{interface
} eq 'ide' || $drive->{interface
} eq 'sata') {
1461 my $maxdev = ($drive->{interface
} eq 'sata') ?
$PVE::QemuServer
::Drive
::MAX_SATA_DISKS
: 2;
1462 my $controller = int($drive->{index} / $maxdev);
1463 my $unit = $drive->{index} % $maxdev;
1464 my $devicetype = ($drive->{media
} && $drive->{media
} eq 'cdrom') ?
"cd" : "hd";
1466 $device = "ide-$devicetype";
1467 if ($drive->{interface
} eq 'ide') {
1468 $device .= ",bus=ide.$controller,unit=$unit";
1470 $device .= ",bus=ahci$controller.$unit";
1472 $device .= ",drive=drive-$drive_id,id=$drive_id";
1474 if ($devicetype eq 'hd') {
1475 if (my $model = $drive->{model
}) {
1476 $model = URI
::Escape
::uri_unescape
($model);
1477 $device .= ",model=$model";
1479 if ($drive->{ssd
}) {
1480 $device .= ",rotation_rate=1";
1483 $device .= ",wwn=$drive->{wwn}" if $drive->{wwn
};
1484 } elsif ($drive->{interface
} eq 'usb') {
1486 # -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0
1488 die "unsupported interface type";
1491 $device .= ",bootindex=$drive->{bootindex}" if $drive->{bootindex
};
1493 if (my $serial = $drive->{serial
}) {
1494 $serial = URI
::Escape
::uri_unescape
($serial);
1495 $device .= ",serial=$serial";
1502 sub get_initiator_name
{
1505 my $fh = IO
::File-
>new('/etc/iscsi/initiatorname.iscsi') || return;
1506 while (defined(my $line = <$fh>)) {
1507 next if $line !~ m/^\s*InitiatorName\s*=\s*([\.\-:\w]+)/;
1516 sub print_drive_commandline_full
{
1517 my ($storecfg, $vmid, $drive) = @_;
1520 my $volid = $drive->{file
};
1523 if (drive_is_cdrom
($drive)) {
1524 $path = get_iso_path
($storecfg, $vmid, $volid);
1526 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
1528 $path = PVE
::Storage
::path
($storecfg, $volid);
1529 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
1530 $format = qemu_img_format
($scfg, $volname);
1538 my @qemu_drive_options = qw(heads secs cyls trans media format cache rerror werror aio discard);
1539 foreach my $o (@qemu_drive_options) {
1540 $opts .= ",$o=$drive->{$o}" if defined($drive->{$o});
1543 # snapshot only accepts on|off
1544 if (defined($drive->{snapshot
})) {
1545 my $v = $drive->{snapshot
} ?
'on' : 'off';
1546 $opts .= ",snapshot=$v";
1549 foreach my $type (['', '-total'], [_rd
=> '-read'], [_wr
=> '-write']) {
1550 my ($dir, $qmpname) = @$type;
1551 if (my $v = $drive->{"mbps$dir"}) {
1552 $opts .= ",throttling.bps$qmpname=".int($v*1024*1024);
1554 if (my $v = $drive->{"mbps${dir}_max"}) {
1555 $opts .= ",throttling.bps$qmpname-max=".int($v*1024*1024);
1557 if (my $v = $drive->{"bps${dir}_max_length"}) {
1558 $opts .= ",throttling.bps$qmpname-max-length=$v";
1560 if (my $v = $drive->{"iops${dir}"}) {
1561 $opts .= ",throttling.iops$qmpname=$v";
1563 if (my $v = $drive->{"iops${dir}_max"}) {
1564 $opts .= ",throttling.iops$qmpname-max=$v";
1566 if (my $v = $drive->{"iops${dir}_max_length"}) {
1567 $opts .= ",throttling.iops$qmpname-max-length=$v";
1571 $opts .= ",format=$format" if $format && !$drive->{format
};
1573 my $cache_direct = 0;
1575 if (my $cache = $drive->{cache
}) {
1576 $cache_direct = $cache =~ /^(?:off|none|directsync)$/;
1577 } elsif (!drive_is_cdrom
($drive)) {
1578 $opts .= ",cache=none";
1582 # aio native works only with O_DIRECT
1583 if (!$drive->{aio
}) {
1585 $opts .= ",aio=native";
1587 $opts .= ",aio=threads";
1591 if (!drive_is_cdrom
($drive)) {
1593 if (defined($drive->{detect_zeroes
}) && !$drive->{detect_zeroes
}) {
1594 $detectzeroes = 'off';
1595 } elsif ($drive->{discard
}) {
1596 $detectzeroes = $drive->{discard
} eq 'on' ?
'unmap' : 'on';
1598 # This used to be our default with discard not being specified:
1599 $detectzeroes = 'on';
1601 $opts .= ",detect-zeroes=$detectzeroes" if $detectzeroes;
1604 my $pathinfo = $path ?
"file=$path," : '';
1606 return "${pathinfo}if=none,id=drive-$drive->{interface}$drive->{index}$opts";
1609 sub print_netdevice_full
{
1610 my ($vmid, $conf, $net, $netid, $bridges, $use_old_bios_files, $arch, $machine_type) = @_;
1612 my $device = $net->{model
};
1613 if ($net->{model
} eq 'virtio') {
1614 $device = 'virtio-net-pci';
1617 my $pciaddr = print_pci_addr
("$netid", $bridges, $arch, $machine_type);
1618 my $tmpstr = "$device,mac=$net->{macaddr},netdev=$netid$pciaddr,id=$netid";
1619 if ($net->{queues
} && $net->{queues
} > 1 && $net->{model
} eq 'virtio'){
1620 # Consider we have N queues, the number of vectors needed is 2 * N + 2, i.e., one per in
1621 # and out of each queue plus one config interrupt and control vector queue
1622 my $vectors = $net->{queues
} * 2 + 2;
1623 $tmpstr .= ",vectors=$vectors,mq=on";
1625 $tmpstr .= ",bootindex=$net->{bootindex}" if $net->{bootindex
} ;
1627 if (my $mtu = $net->{mtu
}) {
1628 if ($net->{model
} eq 'virtio' && $net->{bridge
}) {
1629 my $bridge_mtu = PVE
::Network
::read_bridge_mtu
($net->{bridge
});
1632 } elsif ($mtu < 576) {
1633 die "netdev $netid: MTU '$mtu' is smaller than the IP minimum MTU '576'\n";
1634 } elsif ($mtu > $bridge_mtu) {
1635 die "netdev $netid: MTU '$mtu' is bigger than the bridge MTU '$bridge_mtu'\n";
1637 $tmpstr .= ",host_mtu=$mtu";
1639 warn "WARN: netdev $netid: ignoring MTU '$mtu', not using VirtIO or no bridge configured.\n";
1643 if ($use_old_bios_files) {
1645 if ($device eq 'virtio-net-pci') {
1646 $romfile = 'pxe-virtio.rom';
1647 } elsif ($device eq 'e1000') {
1648 $romfile = 'pxe-e1000.rom';
1649 } elsif ($device eq 'ne2k') {
1650 $romfile = 'pxe-ne2k_pci.rom';
1651 } elsif ($device eq 'pcnet') {
1652 $romfile = 'pxe-pcnet.rom';
1653 } elsif ($device eq 'rtl8139') {
1654 $romfile = 'pxe-rtl8139.rom';
1656 $tmpstr .= ",romfile=$romfile" if $romfile;
1662 sub print_netdev_full
{
1663 my ($vmid, $conf, $arch, $net, $netid, $hotplug) = @_;
1666 if ($netid =~ m/^net(\d+)$/) {
1670 die "got strange net id '$i'\n" if $i >= ${MAX_NETS
};
1672 my $ifname = "tap${vmid}i$i";
1674 # kvm uses TUNSETIFF ioctl, and that limits ifname length
1675 die "interface name '$ifname' is too long (max 15 character)\n"
1676 if length($ifname) >= 16;
1678 my $vhostparam = '';
1679 if (is_native
($arch)) {
1680 $vhostparam = ',vhost=on' if kernel_has_vhost_net
() && $net->{model
} eq 'virtio';
1683 my $vmname = $conf->{name
} || "vm$vmid";
1686 my $script = $hotplug ?
"pve-bridge-hotplug" : "pve-bridge";
1688 if ($net->{bridge
}) {
1689 $netdev = "type=tap,id=$netid,ifname=${ifname},script=/var/lib/qemu-server/$script"
1690 .",downscript=/var/lib/qemu-server/pve-bridgedown$vhostparam";
1692 $netdev = "type=user,id=$netid,hostname=$vmname";
1695 $netdev .= ",queues=$net->{queues}" if ($net->{queues
} && $net->{model
} eq 'virtio');
1701 'cirrus' => 'cirrus-vga',
1703 'vmware' => 'vmware-svga',
1704 'virtio' => 'virtio-vga',
1707 sub print_vga_device
{
1708 my ($conf, $vga, $arch, $machine_version, $machine, $id, $qxlnum, $bridges) = @_;
1710 my $type = $vga_map->{$vga->{type
}};
1711 if ($arch eq 'aarch64' && defined($type) && $type eq 'virtio-vga') {
1712 $type = 'virtio-gpu';
1714 my $vgamem_mb = $vga->{memory
};
1716 my $max_outputs = '';
1718 $type = $id ?
'qxl' : 'qxl-vga';
1720 if (!$conf->{ostype
} || $conf->{ostype
} =~ m/^(?:l\d\d)|(?:other)$/) {
1721 # set max outputs so linux can have up to 4 qxl displays with one device
1722 if (min_version
($machine_version, 4, 1)) {
1723 $max_outputs = ",max_outputs=4";
1728 die "no devicetype for $vga->{type}\n" if !$type;
1732 if ($vga->{type
} eq 'virtio') {
1733 my $bytes = PVE
::Tools
::convert_size
($vgamem_mb, "mb" => "b");
1734 $memory = ",max_hostmem=$bytes";
1736 # from https://www.spice-space.org/multiple-monitors.html
1737 $memory = ",vgamem_mb=$vga->{memory}";
1738 my $ram = $vgamem_mb * 4;
1739 my $vram = $vgamem_mb * 2;
1740 $memory .= ",ram_size_mb=$ram,vram_size_mb=$vram";
1742 $memory = ",vgamem_mb=$vga->{memory}";
1744 } elsif ($qxlnum && $id) {
1745 $memory = ",ram_size=67108864,vram_size=33554432";
1749 if ($type eq 'VGA' && windows_version
($conf->{ostype
})) {
1750 $edidoff=",edid=off" if (!defined($conf->{bios
}) || $conf->{bios
} ne 'ovmf');
1753 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
1754 my $vgaid = "vga" . ($id // '');
1757 if ($q35 && $vgaid eq 'vga') {
1758 # the first display uses pcie.0 bus on q35 machines
1759 $pciaddr = print_pcie_addr
($vgaid, $bridges, $arch, $machine);
1761 $pciaddr = print_pci_addr
($vgaid, $bridges, $arch, $machine);
1764 return "$type,id=${vgaid}${memory}${max_outputs}${pciaddr}${edidoff}";
1767 sub parse_number_sets
{
1770 foreach my $part (split(/;/, $set)) {
1771 if ($part =~ /^\s*(\d+)(?:-(\d+))?\s*$/) {
1772 die "invalid range: $part ($2 < $1)\n" if defined($2) && $2 < $1;
1773 push @$res, [ $1, $2 ];
1775 die "invalid range: $part\n";
1784 my $res = parse_property_string
($numa_fmt, $data);
1785 $res->{cpus
} = parse_number_sets
($res->{cpus
}) if defined($res->{cpus
});
1786 $res->{hostnodes
} = parse_number_sets
($res->{hostnodes
}) if defined($res->{hostnodes
});
1790 # netX: e1000=XX:XX:XX:XX:XX:XX,bridge=vmbr0,rate=<mbps>
1794 my $res = eval { parse_property_string
($net_fmt, $data) };
1799 if (!defined($res->{macaddr
})) {
1800 my $dc = PVE
::Cluster
::cfs_read_file
('datacenter.cfg');
1801 $res->{macaddr
} = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
});
1806 # ipconfigX ip=cidr,gw=ip,ip6=cidr,gw6=ip
1807 sub parse_ipconfig
{
1810 my $res = eval { parse_property_string
($ipconfig_fmt, $data) };
1816 if ($res->{gw
} && !$res->{ip
}) {
1817 warn 'gateway specified without specifying an IP address';
1820 if ($res->{gw6
} && !$res->{ip6
}) {
1821 warn 'IPv6 gateway specified without specifying an IPv6 address';
1824 if ($res->{gw
} && $res->{ip
} eq 'dhcp') {
1825 warn 'gateway specified together with DHCP';
1828 if ($res->{gw6
} && $res->{ip6
} !~ /^$IPV6RE/) {
1830 warn "IPv6 gateway specified together with $res->{ip6} address";
1834 if (!$res->{ip
} && !$res->{ip6
}) {
1835 return { ip
=> 'dhcp', ip6
=> 'dhcp' };
1844 return PVE
::JSONSchema
::print_property_string
($net, $net_fmt);
1847 sub add_random_macs
{
1848 my ($settings) = @_;
1850 foreach my $opt (keys %$settings) {
1851 next if $opt !~ m/^net(\d+)$/;
1852 my $net = parse_net
($settings->{$opt});
1854 $settings->{$opt} = print_net
($net);
1858 sub vm_is_volid_owner
{
1859 my ($storecfg, $vmid, $volid) = @_;
1861 if ($volid !~ m
|^/|) {
1863 eval { ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid); };
1864 if ($owner && ($owner == $vmid)) {
1872 sub vmconfig_register_unused_drive
{
1873 my ($storecfg, $vmid, $conf, $drive) = @_;
1875 if (drive_is_cloudinit
($drive)) {
1876 eval { PVE
::Storage
::vdisk_free
($storecfg, $drive->{file
}) };
1878 } elsif (!drive_is_cdrom
($drive)) {
1879 my $volid = $drive->{file
};
1880 if (vm_is_volid_owner
($storecfg, $vmid, $volid)) {
1881 PVE
::QemuConfig-
>add_unused_volume($conf, $volid, $vmid);
1886 # smbios: [manufacturer=str][,product=str][,version=str][,serial=str][,uuid=uuid][,sku=str][,family=str][,base64=bool]
1890 pattern
=> '[a-fA-F0-9]{8}(?:-[a-fA-F0-9]{4}){3}-[a-fA-F0-9]{12}',
1891 format_description
=> 'UUID',
1892 description
=> "Set SMBIOS1 UUID.",
1897 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1898 format_description
=> 'Base64 encoded string',
1899 description
=> "Set SMBIOS1 version.",
1904 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1905 format_description
=> 'Base64 encoded string',
1906 description
=> "Set SMBIOS1 serial number.",
1911 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1912 format_description
=> 'Base64 encoded string',
1913 description
=> "Set SMBIOS1 manufacturer.",
1918 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1919 format_description
=> 'Base64 encoded string',
1920 description
=> "Set SMBIOS1 product ID.",
1925 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1926 format_description
=> 'Base64 encoded string',
1927 description
=> "Set SMBIOS1 SKU string.",
1932 pattern
=> '[A-Za-z0-9+\/]+={0,2}',
1933 format_description
=> 'Base64 encoded string',
1934 description
=> "Set SMBIOS1 family string.",
1939 description
=> 'Flag to indicate that the SMBIOS values are base64 encoded',
1947 my $res = eval { parse_property_string
($smbios1_fmt, $data) };
1954 return PVE
::JSONSchema
::print_property_string
($smbios1, $smbios1_fmt);
1957 PVE
::JSONSchema
::register_format
('pve-qm-smbios1', $smbios1_fmt);
1959 sub parse_watchdog
{
1964 my $res = eval { parse_property_string
($watchdog_fmt, $value) };
1969 sub parse_guest_agent
{
1972 return {} if !defined($conf->{agent
});
1974 my $res = eval { parse_property_string
($agent_fmt, $conf->{agent
}) };
1977 # if the agent is disabled ignore the other potentially set properties
1978 return {} if !$res->{enabled
};
1983 my ($conf, $key) = @_;
1984 return undef if !defined($conf->{agent
});
1986 my $agent = parse_guest_agent
($conf);
1987 return $agent->{$key};
1993 return {} if !$value;
1994 my $res = eval { parse_property_string
($vga_fmt, $value) };
2004 my $res = eval { parse_property_string
($rng_fmt, $value) };
2009 PVE
::JSONSchema
::register_format
('pve-qm-usb-device', \
&verify_usb_device
);
2010 sub verify_usb_device
{
2011 my ($value, $noerr) = @_;
2013 return $value if parse_usb_device
($value);
2017 die "unable to parse usb device\n";
2020 # add JSON properties for create and set function
2021 sub json_config_properties
{
2024 foreach my $opt (keys %$confdesc) {
2025 next if $opt eq 'parent' || $opt eq 'snaptime' || $opt eq 'vmstate' ||
2026 $opt eq 'runningmachine' || $opt eq 'runningcpu';
2027 $prop->{$opt} = $confdesc->{$opt};
2033 # return copy of $confdesc_cloudinit to generate documentation
2034 sub cloudinit_config_properties
{
2036 return dclone
($confdesc_cloudinit);
2040 my ($key, $value) = @_;
2042 die "unknown setting '$key'\n" if !$confdesc->{$key};
2044 my $type = $confdesc->{$key}->{type
};
2046 if (!defined($value)) {
2047 die "got undefined value\n";
2050 if ($value =~ m/[\n\r]/) {
2051 die "property contains a line feed\n";
2054 if ($type eq 'boolean') {
2055 return 1 if ($value eq '1') || ($value =~ m/^(on|yes|true)$/i);
2056 return 0 if ($value eq '0') || ($value =~ m/^(off|no|false)$/i);
2057 die "type check ('boolean') failed - got '$value'\n";
2058 } elsif ($type eq 'integer') {
2059 return int($1) if $value =~ m/^(\d+)$/;
2060 die "type check ('integer') failed - got '$value'\n";
2061 } elsif ($type eq 'number') {
2062 return $value if $value =~ m/^(\d+)(\.\d+)?$/;
2063 die "type check ('number') failed - got '$value'\n";
2064 } elsif ($type eq 'string') {
2065 if (my $fmt = $confdesc->{$key}->{format
}) {
2066 PVE
::JSONSchema
::check_format
($fmt, $value);
2069 $value =~ s/^\"(.*)\"$/$1/;
2072 die "internal error"
2077 my ($storecfg, $vmid, $skiplock, $replacement_conf, $purge_unreferenced) = @_;
2079 my $conf = PVE
::QemuConfig-
>load_config($vmid);
2081 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
2083 if ($conf->{template
}) {
2084 # check if any base image is still used by a linked clone
2085 PVE
::QemuConfig-
>foreach_volume($conf, sub {
2086 my ($ds, $drive) = @_;
2087 return if drive_is_cdrom
($drive);
2089 my $volid = $drive->{file
};
2090 return if !$volid || $volid =~ m
|^/|;
2092 die "base volume '$volid' is still in use by linked cloned\n"
2093 if PVE
::Storage
::volume_is_base_and_used
($storecfg, $volid);
2098 # only remove disks owned by this VM (referenced in the config)
2099 PVE
::QemuConfig-
>foreach_volume_full($conf, { include_unused
=> 1 }, sub {
2100 my ($ds, $drive) = @_;
2101 return if drive_is_cdrom
($drive, 1);
2103 my $volid = $drive->{file
};
2104 return if !$volid || $volid =~ m
|^/|;
2106 my ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid);
2107 return if !$path || !$owner || ($owner != $vmid);
2109 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid) };
2110 warn "Could not remove disk '$volid', check manually: $@" if $@;
2113 if ($purge_unreferenced) { # also remove unreferenced disk
2114 my $vmdisks = PVE
::Storage
::vdisk_list
($storecfg, undef, $vmid);
2115 PVE
::Storage
::foreach_volid
($vmdisks, sub {
2116 my ($volid, $sid, $volname, $d) = @_;
2117 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid) };
2122 if (defined $replacement_conf) {
2123 PVE
::QemuConfig-
>write_config($vmid, $replacement_conf);
2125 PVE
::QemuConfig-
>destroy_config($vmid);
2129 sub parse_vm_config
{
2130 my ($filename, $raw) = @_;
2132 return if !defined($raw);
2135 digest
=> Digest
::SHA
::sha1_hex
($raw),
2140 $filename =~ m
|/qemu-server/(\d
+)\
.conf
$|
2141 || die "got strange filename '$filename'";
2149 my @lines = split(/\n/, $raw);
2150 foreach my $line (@lines) {
2151 next if $line =~ m/^\s*$/;
2153 if ($line =~ m/^\[PENDING\]\s*$/i) {
2154 $section = 'pending';
2155 if (defined($descr)) {
2157 $conf->{description
} = $descr;
2160 $conf = $res->{$section} = {};
2163 } elsif ($line =~ m/^\[([a-z][a-z0-9_\-]+)\]\s*$/i) {
2165 if (defined($descr)) {
2167 $conf->{description
} = $descr;
2170 $conf = $res->{snapshots
}->{$section} = {};
2174 if ($line =~ m/^\#(.*)\s*$/) {
2175 $descr = '' if !defined($descr);
2176 $descr .= PVE
::Tools
::decode_text
($1) . "\n";
2180 if ($line =~ m/^(description):\s*(.*\S)\s*$/) {
2181 $descr = '' if !defined($descr);
2182 $descr .= PVE
::Tools
::decode_text
($2);
2183 } elsif ($line =~ m/snapstate:\s*(prepare|delete)\s*$/) {
2184 $conf->{snapstate
} = $1;
2185 } elsif ($line =~ m/^(args):\s*(.*\S)\s*$/) {
2188 $conf->{$key} = $value;
2189 } elsif ($line =~ m/^delete:\s*(.*\S)\s*$/) {
2191 if ($section eq 'pending') {
2192 $conf->{delete} = $value; # we parse this later
2194 warn "vm $vmid - propertry 'delete' is only allowed in [PENDING]\n";
2196 } elsif ($line =~ m/^([a-z][a-z_]*\d*):\s*(.+?)\s*$/) {
2199 eval { $value = check_type
($key, $value); };
2201 warn "vm $vmid - unable to parse value of '$key' - $@";
2203 $key = 'ide2' if $key eq 'cdrom';
2204 my $fmt = $confdesc->{$key}->{format
};
2205 if ($fmt && $fmt =~ /^pve-qm-(?:ide|scsi|virtio|sata)$/) {
2206 my $v = parse_drive
($key, $value);
2207 if (my $volid = filename_to_volume_id
($vmid, $v->{file
}, $v->{media
})) {
2208 $v->{file
} = $volid;
2209 $value = print_drive
($v);
2211 warn "vm $vmid - unable to parse value of '$key'\n";
2216 $conf->{$key} = $value;
2219 warn "vm $vmid - unable to parse config: $line\n";
2223 if (defined($descr)) {
2225 $conf->{description
} = $descr;
2227 delete $res->{snapstate
}; # just to be sure
2232 sub write_vm_config
{
2233 my ($filename, $conf) = @_;
2235 delete $conf->{snapstate
}; # just to be sure
2237 if ($conf->{cdrom
}) {
2238 die "option ide2 conflicts with cdrom\n" if $conf->{ide2
};
2239 $conf->{ide2
} = $conf->{cdrom
};
2240 delete $conf->{cdrom
};
2243 # we do not use 'smp' any longer
2244 if ($conf->{sockets
}) {
2245 delete $conf->{smp
};
2246 } elsif ($conf->{smp
}) {
2247 $conf->{sockets
} = $conf->{smp
};
2248 delete $conf->{cores
};
2249 delete $conf->{smp
};
2252 my $used_volids = {};
2254 my $cleanup_config = sub {
2255 my ($cref, $pending, $snapname) = @_;
2257 foreach my $key (keys %$cref) {
2258 next if $key eq 'digest' || $key eq 'description' || $key eq 'snapshots' ||
2259 $key eq 'snapstate' || $key eq 'pending';
2260 my $value = $cref->{$key};
2261 if ($key eq 'delete') {
2262 die "propertry 'delete' is only allowed in [PENDING]\n"
2264 # fixme: check syntax?
2267 eval { $value = check_type
($key, $value); };
2268 die "unable to parse value of '$key' - $@" if $@;
2270 $cref->{$key} = $value;
2272 if (!$snapname && is_valid_drivename
($key)) {
2273 my $drive = parse_drive
($key, $value);
2274 $used_volids->{$drive->{file
}} = 1 if $drive && $drive->{file
};
2279 &$cleanup_config($conf);
2281 &$cleanup_config($conf->{pending
}, 1);
2283 foreach my $snapname (keys %{$conf->{snapshots
}}) {
2284 die "internal error: snapshot name '$snapname' is forbidden" if lc($snapname) eq 'pending';
2285 &$cleanup_config($conf->{snapshots
}->{$snapname}, undef, $snapname);
2288 # remove 'unusedX' settings if we re-add a volume
2289 foreach my $key (keys %$conf) {
2290 my $value = $conf->{$key};
2291 if ($key =~ m/^unused/ && $used_volids->{$value}) {
2292 delete $conf->{$key};
2296 my $generate_raw_config = sub {
2297 my ($conf, $pending) = @_;
2301 # add description as comment to top of file
2302 if (defined(my $descr = $conf->{description
})) {
2304 foreach my $cl (split(/\n/, $descr)) {
2305 $raw .= '#' . PVE
::Tools
::encode_text
($cl) . "\n";
2308 $raw .= "#\n" if $pending;
2312 foreach my $key (sort keys %$conf) {
2313 next if $key =~ /^(digest|description|pending|snapshots)$/;
2314 $raw .= "$key: $conf->{$key}\n";
2319 my $raw = &$generate_raw_config($conf);
2321 if (scalar(keys %{$conf->{pending
}})){
2322 $raw .= "\n[PENDING]\n";
2323 $raw .= &$generate_raw_config($conf->{pending
}, 1);
2326 foreach my $snapname (sort keys %{$conf->{snapshots
}}) {
2327 $raw .= "\n[$snapname]\n";
2328 $raw .= &$generate_raw_config($conf->{snapshots
}->{$snapname});
2338 # we use static defaults from our JSON schema configuration
2339 foreach my $key (keys %$confdesc) {
2340 if (defined(my $default = $confdesc->{$key}->{default})) {
2341 $res->{$key} = $default;
2349 my $vmlist = PVE
::Cluster
::get_vmlist
();
2351 return $res if !$vmlist || !$vmlist->{ids
};
2352 my $ids = $vmlist->{ids
};
2353 my $nodename = nodename
();
2355 foreach my $vmid (keys %$ids) {
2356 my $d = $ids->{$vmid};
2357 next if !$d->{node
} || $d->{node
} ne $nodename;
2358 next if !$d->{type
} || $d->{type
} ne 'qemu';
2359 $res->{$vmid}->{exists} = 1;
2364 # test if VM uses local resources (to prevent migration)
2365 sub check_local_resources
{
2366 my ($conf, $noerr) = @_;
2370 push @loc_res, "hostusb" if $conf->{hostusb
}; # old syntax
2371 push @loc_res, "hostpci" if $conf->{hostpci
}; # old syntax
2373 push @loc_res, "ivshmem" if $conf->{ivshmem
};
2375 foreach my $k (keys %$conf) {
2376 next if $k =~ m/^usb/ && ($conf->{$k} =~ m/^spice(?![^,])/);
2377 # sockets are safe: they will recreated be on the target side post-migrate
2378 next if $k =~ m/^serial/ && ($conf->{$k} eq 'socket');
2379 push @loc_res, $k if $k =~ m/^(usb|hostpci|serial|parallel)\d+$/;
2382 die "VM uses local resources\n" if scalar @loc_res && !$noerr;
2387 # check if used storages are available on all nodes (use by migrate)
2388 sub check_storage_availability
{
2389 my ($storecfg, $conf, $node) = @_;
2391 PVE
::QemuConfig-
>foreach_volume($conf, sub {
2392 my ($ds, $drive) = @_;
2394 my $volid = $drive->{file
};
2397 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2400 # check if storage is available on both nodes
2401 my $scfg = PVE
::Storage
::storage_check_node
($storecfg, $sid);
2402 PVE
::Storage
::storage_check_node
($storecfg, $sid, $node);
2406 # list nodes where all VM images are available (used by has_feature API)
2408 my ($conf, $storecfg) = @_;
2410 my $nodelist = PVE
::Cluster
::get_nodelist
();
2411 my $nodehash = { map { $_ => 1 } @$nodelist };
2412 my $nodename = nodename
();
2414 PVE
::QemuConfig-
>foreach_volume($conf, sub {
2415 my ($ds, $drive) = @_;
2417 my $volid = $drive->{file
};
2420 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2422 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
2423 if ($scfg->{disable
}) {
2425 } elsif (my $avail = $scfg->{nodes
}) {
2426 foreach my $node (keys %$nodehash) {
2427 delete $nodehash->{$node} if !$avail->{$node};
2429 } elsif (!$scfg->{shared
}) {
2430 foreach my $node (keys %$nodehash) {
2431 delete $nodehash->{$node} if $node ne $nodename
2440 sub check_local_storage_availability
{
2441 my ($conf, $storecfg) = @_;
2443 my $nodelist = PVE
::Cluster
::get_nodelist
();
2444 my $nodehash = { map { $_ => {} } @$nodelist };
2446 PVE
::QemuConfig-
>foreach_volume($conf, sub {
2447 my ($ds, $drive) = @_;
2449 my $volid = $drive->{file
};
2452 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
2454 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
2456 if ($scfg->{disable
}) {
2457 foreach my $node (keys %$nodehash) {
2458 $nodehash->{$node}->{unavailable_storages
}->{$storeid} = 1;
2460 } elsif (my $avail = $scfg->{nodes
}) {
2461 foreach my $node (keys %$nodehash) {
2462 if (!$avail->{$node}) {
2463 $nodehash->{$node}->{unavailable_storages
}->{$storeid} = 1;
2470 foreach my $node (values %$nodehash) {
2471 if (my $unavail = $node->{unavailable_storages
}) {
2472 $node->{unavailable_storages
} = [ sort keys %$unavail ];
2479 # Compat only, use assert_config_exists_on_node and vm_running_locally where possible
2481 my ($vmid, $nocheck, $node) = @_;
2483 PVE
::QemuConfig
::assert_config_exists_on_node
($vmid, $node) if !$nocheck;
2484 return PVE
::QemuServer
::Helpers
::vm_running_locally
($vmid);
2489 my $vzlist = config_list
();
2491 my $fd = IO
::Dir-
>new($PVE::QemuServer
::Helpers
::var_run_tmpdir
) || return $vzlist;
2493 while (defined(my $de = $fd->read)) {
2494 next if $de !~ m/^(\d+)\.pid$/;
2496 next if !defined($vzlist->{$vmid});
2497 if (my $pid = check_running
($vmid)) {
2498 $vzlist->{$vmid}->{pid
} = $pid;
2505 our $vmstatus_return_properties = {
2506 vmid
=> get_standard_option
('pve-vmid'),
2508 description
=> "Qemu process status.",
2510 enum
=> ['stopped', 'running'],
2513 description
=> "Maximum memory in bytes.",
2516 renderer
=> 'bytes',
2519 description
=> "Root disk size in bytes.",
2522 renderer
=> 'bytes',
2525 description
=> "VM name.",
2530 description
=> "Qemu QMP agent status.",
2535 description
=> "PID of running qemu process.",
2540 description
=> "Uptime.",
2543 renderer
=> 'duration',
2546 description
=> "Maximum usable CPUs.",
2551 description
=> "The current config lock, if any.",
2556 description
=> "The current configured tags, if any",
2560 'running-machine' => {
2561 description
=> "The currently running machine type (if running).",
2566 description
=> "The currently running QEMU version (if running).",
2572 my $last_proc_pid_stat;
2574 # get VM status information
2575 # This must be fast and should not block ($full == false)
2576 # We only query KVM using QMP if $full == true (this can be slow)
2578 my ($opt_vmid, $full) = @_;
2582 my $storecfg = PVE
::Storage
::config
();
2584 my $list = vzlist
();
2585 my $defaults = load_defaults
();
2587 my ($uptime) = PVE
::ProcFSTools
::read_proc_uptime
(1);
2589 my $cpucount = $cpuinfo->{cpus
} || 1;
2591 foreach my $vmid (keys %$list) {
2592 next if $opt_vmid && ($vmid ne $opt_vmid);
2594 my $conf = PVE
::QemuConfig-
>load_config($vmid);
2596 my $d = { vmid
=> $vmid };
2597 $d->{pid
} = $list->{$vmid}->{pid
};
2599 # fixme: better status?
2600 $d->{status
} = $list->{$vmid}->{pid
} ?
'running' : 'stopped';
2602 my $size = PVE
::QemuServer
::Drive
::bootdisk_size
($storecfg, $conf);
2603 if (defined($size)) {
2604 $d->{disk
} = 0; # no info available
2605 $d->{maxdisk
} = $size;
2611 $d->{cpus
} = ($conf->{sockets
} || $defaults->{sockets
})
2612 * ($conf->{cores
} || $defaults->{cores
});
2613 $d->{cpus
} = $cpucount if $d->{cpus
} > $cpucount;
2614 $d->{cpus
} = $conf->{vcpus
} if $conf->{vcpus
};
2616 $d->{name
} = $conf->{name
} || "VM $vmid";
2617 $d->{maxmem
} = $conf->{memory
} ?
$conf->{memory
}*(1024*1024)
2618 : $defaults->{memory
}*(1024*1024);
2620 if ($conf->{balloon
}) {
2621 $d->{balloon_min
} = $conf->{balloon
}*(1024*1024);
2622 $d->{shares
} = defined($conf->{shares
}) ?
$conf->{shares
}
2623 : $defaults->{shares
};
2634 $d->{diskwrite
} = 0;
2636 $d->{template
} = PVE
::QemuConfig-
>is_template($conf);
2638 $d->{serial
} = 1 if conf_has_serial
($conf);
2639 $d->{lock} = $conf->{lock} if $conf->{lock};
2640 $d->{tags
} = $conf->{tags
} if defined($conf->{tags
});
2645 my $netdev = PVE
::ProcFSTools
::read_proc_net_dev
();
2646 foreach my $dev (keys %$netdev) {
2647 next if $dev !~ m/^tap([1-9]\d*)i/;
2649 my $d = $res->{$vmid};
2652 $d->{netout
} += $netdev->{$dev}->{receive
};
2653 $d->{netin
} += $netdev->{$dev}->{transmit
};
2656 $d->{nics
}->{$dev}->{netout
} = $netdev->{$dev}->{receive
};
2657 $d->{nics
}->{$dev}->{netin
} = $netdev->{$dev}->{transmit
};
2662 my $ctime = gettimeofday
;
2664 foreach my $vmid (keys %$list) {
2666 my $d = $res->{$vmid};
2667 my $pid = $d->{pid
};
2670 my $pstat = PVE
::ProcFSTools
::read_proc_pid_stat
($pid);
2671 next if !$pstat; # not running
2673 my $used = $pstat->{utime} + $pstat->{stime
};
2675 $d->{uptime
} = int(($uptime - $pstat->{starttime
})/$cpuinfo->{user_hz
});
2677 if ($pstat->{vsize
}) {
2678 $d->{mem
} = int(($pstat->{rss
}/$pstat->{vsize
})*$d->{maxmem
});
2681 my $old = $last_proc_pid_stat->{$pid};
2683 $last_proc_pid_stat->{$pid} = {
2691 my $dtime = ($ctime - $old->{time}) * $cpucount * $cpuinfo->{user_hz
};
2693 if ($dtime > 1000) {
2694 my $dutime = $used - $old->{used
};
2696 $d->{cpu
} = (($dutime/$dtime)* $cpucount) / $d->{cpus
};
2697 $last_proc_pid_stat->{$pid} = {
2703 $d->{cpu
} = $old->{cpu
};
2707 return $res if !$full;
2709 my $qmpclient = PVE
::QMPClient-
>new();
2711 my $ballooncb = sub {
2712 my ($vmid, $resp) = @_;
2714 my $info = $resp->{'return'};
2715 return if !$info->{max_mem
};
2717 my $d = $res->{$vmid};
2719 # use memory assigned to VM
2720 $d->{maxmem
} = $info->{max_mem
};
2721 $d->{balloon
} = $info->{actual
};
2723 if (defined($info->{total_mem
}) && defined($info->{free_mem
})) {
2724 $d->{mem
} = $info->{total_mem
} - $info->{free_mem
};
2725 $d->{freemem
} = $info->{free_mem
};
2728 $d->{ballooninfo
} = $info;
2731 my $blockstatscb = sub {
2732 my ($vmid, $resp) = @_;
2733 my $data = $resp->{'return'} || [];
2734 my $totalrdbytes = 0;
2735 my $totalwrbytes = 0;
2737 for my $blockstat (@$data) {
2738 $totalrdbytes = $totalrdbytes + $blockstat->{stats
}->{rd_bytes
};
2739 $totalwrbytes = $totalwrbytes + $blockstat->{stats
}->{wr_bytes
};
2741 $blockstat->{device
} =~ s/drive-//;
2742 $res->{$vmid}->{blockstat
}->{$blockstat->{device
}} = $blockstat->{stats
};
2744 $res->{$vmid}->{diskread
} = $totalrdbytes;
2745 $res->{$vmid}->{diskwrite
} = $totalwrbytes;
2748 my $machinecb = sub {
2749 my ($vmid, $resp) = @_;
2750 my $data = $resp->{'return'} || [];
2752 $res->{$vmid}->{'running-machine'} =
2753 PVE
::QemuServer
::Machine
::current_from_query_machines
($data);
2756 my $versioncb = sub {
2757 my ($vmid, $resp) = @_;
2758 my $data = $resp->{'return'} // {};
2759 my $version = 'unknown';
2761 if (my $v = $data->{qemu
}) {
2762 $version = $v->{major
} . "." . $v->{minor
} . "." . $v->{micro
};
2765 $res->{$vmid}->{'running-qemu'} = $version;
2768 my $statuscb = sub {
2769 my ($vmid, $resp) = @_;
2771 $qmpclient->queue_cmd($vmid, $blockstatscb, 'query-blockstats');
2772 $qmpclient->queue_cmd($vmid, $machinecb, 'query-machines');
2773 $qmpclient->queue_cmd($vmid, $versioncb, 'query-version');
2774 # this fails if ballon driver is not loaded, so this must be
2775 # the last commnand (following command are aborted if this fails).
2776 $qmpclient->queue_cmd($vmid, $ballooncb, 'query-balloon');
2778 my $status = 'unknown';
2779 if (!defined($status = $resp->{'return'}->{status
})) {
2780 warn "unable to get VM status\n";
2784 $res->{$vmid}->{qmpstatus
} = $resp->{'return'}->{status
};
2787 foreach my $vmid (keys %$list) {
2788 next if $opt_vmid && ($vmid ne $opt_vmid);
2789 next if !$res->{$vmid}->{pid
}; # not running
2790 $qmpclient->queue_cmd($vmid, $statuscb, 'query-status');
2793 $qmpclient->queue_execute(undef, 2);
2795 foreach my $vmid (keys %$list) {
2796 next if $opt_vmid && ($vmid ne $opt_vmid);
2797 next if !$res->{$vmid}->{pid
}; #not running
2799 # we can't use the $qmpclient since it might have already aborted on
2800 # 'query-balloon', but this might also fail for older versions...
2801 my $qemu_support = eval { mon_cmd
($vmid, "query-proxmox-support") };
2802 $res->{$vmid}->{'proxmox-support'} = $qemu_support // {};
2805 foreach my $vmid (keys %$list) {
2806 next if $opt_vmid && ($vmid ne $opt_vmid);
2807 $res->{$vmid}->{qmpstatus
} = $res->{$vmid}->{status
} if !$res->{$vmid}->{qmpstatus
};
2813 sub conf_has_serial
{
2816 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
2817 if ($conf->{"serial$i"}) {
2825 sub conf_has_audio
{
2826 my ($conf, $id) = @_;
2829 my $audio = $conf->{"audio$id"};
2830 return if !defined($audio);
2832 my $audioproperties = parse_property_string
($audio_fmt, $audio);
2833 my $audiodriver = $audioproperties->{driver
} // 'spice';
2836 dev
=> $audioproperties->{device
},
2837 dev_id
=> "audiodev$id",
2838 backend
=> $audiodriver,
2839 backend_id
=> "$audiodriver-backend${id}",
2844 my ($audio, $audiopciaddr, $machine_version) = @_;
2848 my $id = $audio->{dev_id
};
2850 if (min_version
($machine_version, 4, 2)) {
2851 $audiodev = ",audiodev=$audio->{backend_id}";
2854 if ($audio->{dev
} eq 'AC97') {
2855 push @$devs, '-device', "AC97,id=${id}${audiopciaddr}$audiodev";
2856 } elsif ($audio->{dev
} =~ /intel\-hda$/) {
2857 push @$devs, '-device', "$audio->{dev},id=${id}${audiopciaddr}";
2858 push @$devs, '-device', "hda-micro,id=${id}-codec0,bus=${id}.0,cad=0$audiodev";
2859 push @$devs, '-device', "hda-duplex,id=${id}-codec1,bus=${id}.0,cad=1$audiodev";
2861 die "unkown audio device '$audio->{dev}', implement me!";
2864 push @$devs, '-audiodev', "$audio->{backend},id=$audio->{backend_id}";
2869 sub vga_conf_has_spice
{
2872 my $vgaconf = parse_vga
($vga);
2873 my $vgatype = $vgaconf->{type
};
2874 return 0 if !$vgatype || $vgatype !~ m/^qxl([234])?$/;
2881 return get_host_arch
() eq $arch;
2886 return $conf->{arch
} // get_host_arch
();
2889 my $default_machines = {
2894 sub get_installed_machine_version
{
2895 my ($kvmversion) = @_;
2896 $kvmversion = kvm_user_version
() if !defined($kvmversion);
2897 $kvmversion =~ m/^(\d+\.\d+)/;
2901 sub windows_get_pinned_machine_version
{
2902 my ($machine, $base_version, $kvmversion) = @_;
2904 my $pin_version = $base_version;
2905 if (!defined($base_version) ||
2906 !PVE
::QemuServer
::Machine
::can_run_pve_machine_version
($base_version, $kvmversion)
2908 $pin_version = get_installed_machine_version
($kvmversion);
2910 if (!$machine || $machine eq 'pc') {
2911 $machine = "pc-i440fx-$pin_version";
2912 } elsif ($machine eq 'q35') {
2913 $machine = "pc-q35-$pin_version";
2914 } elsif ($machine eq 'virt') {
2915 $machine = "virt-$pin_version";
2917 warn "unknown machine type '$machine', not touching that!\n";
2923 sub get_vm_machine
{
2924 my ($conf, $forcemachine, $arch, $add_pve_version, $kvmversion) = @_;
2926 my $machine = $forcemachine || $conf->{machine
};
2928 if (!$machine || $machine =~ m/^(?:pc|q35|virt)$/) {
2929 $kvmversion //= kvm_user_version
();
2930 # we must pin Windows VMs without a specific version to 5.1, as 5.2 fixed a bug in ACPI
2931 # layout which confuses windows quite a bit and may result in various regressions..
2932 # see: https://lists.gnu.org/archive/html/qemu-devel/2021-02/msg08484.html
2933 if (windows_version
($conf->{ostype
})) {
2934 $machine = windows_get_pinned_machine_version
($machine, '5.1', $kvmversion);
2937 $machine ||= $default_machines->{$arch};
2938 if ($add_pve_version) {
2939 my $pvever = PVE
::QemuServer
::Machine
::get_pve_version
($kvmversion);
2940 $machine .= "+pve$pvever";
2944 if ($add_pve_version && $machine !~ m/\+pve\d+$/) {
2945 # for version-pinned machines that do not include a pve-version (e.g.
2946 # pc-q35-4.1), we assume 0 to keep them stable in case we bump
2947 $machine .= '+pve0';
2953 sub get_ovmf_files
($) {
2956 my $ovmf = $OVMF->{$arch}
2957 or die "no OVMF images known for architecture '$arch'\n";
2963 aarch64
=> '/usr/bin/qemu-system-aarch64',
2964 x86_64
=> '/usr/bin/qemu-system-x86_64',
2966 sub get_command_for_arch
($) {
2968 return '/usr/bin/kvm' if is_native
($arch);
2970 my $cmd = $Arch2Qemu->{$arch}
2971 or die "don't know how to emulate architecture '$arch'\n";
2975 # To use query_supported_cpu_flags and query_understood_cpu_flags to get flags
2976 # to use in a QEMU command line (-cpu element), first array_intersect the result
2977 # of query_supported_ with query_understood_. This is necessary because:
2979 # a) query_understood_ returns flags the host cannot use and
2980 # b) query_supported_ (rather the QMP call) doesn't actually return CPU
2981 # flags, but CPU settings - with most of them being flags. Those settings
2982 # (and some flags, curiously) cannot be specified as a "-cpu" argument.
2984 # query_supported_ needs to start up to 2 temporary VMs and is therefore rather
2985 # expensive. If you need the value returned from this, you can get it much
2986 # cheaper from pmxcfs using PVE::Cluster::get_node_kv('cpuflags-$accel') with
2987 # $accel being 'kvm' or 'tcg'.
2989 # pvestatd calls this function on startup and whenever the QEMU/KVM version
2990 # changes, automatically populating pmxcfs.
2992 # Returns: { kvm => [ flagX, flagY, ... ], tcg => [ flag1, flag2, ... ] }
2993 # since kvm and tcg machines support different flags
2995 sub query_supported_cpu_flags
{
2998 $arch //= get_host_arch
();
2999 my $default_machine = $default_machines->{$arch};
3003 # FIXME: Once this is merged, the code below should work for ARM as well:
3004 # https://lists.nongnu.org/archive/html/qemu-devel/2019-06/msg04947.html
3005 die "QEMU/KVM cannot detect CPU flags on ARM (aarch64)\n" if
3008 my $kvm_supported = defined(kvm_version
());
3009 my $qemu_cmd = get_command_for_arch
($arch);
3011 my $pidfile = PVE
::QemuServer
::Helpers
::pidfile_name
($fakevmid);
3013 # Start a temporary (frozen) VM with vmid -1 to allow sending a QMP command
3014 my $query_supported_run_qemu = sub {
3020 '-machine', $default_machine,
3022 '-chardev', "socket,id=qmp,path=/var/run/qemu-server/$fakevmid.qmp,server,nowait",
3023 '-mon', 'chardev=qmp,mode=control',
3024 '-pidfile', $pidfile,
3029 push @$cmd, '-accel', 'tcg';
3032 my $rc = run_command
($cmd, noerr
=> 1, quiet
=> 0);
3033 die "QEMU flag querying VM exited with code " . $rc if $rc;
3036 my $cmd_result = mon_cmd
(
3038 'query-cpu-model-expansion',
3040 model
=> { name
=> 'host' }
3043 my $props = $cmd_result->{model
}->{props
};
3044 foreach my $prop (keys %$props) {
3045 next if $props->{$prop} ne '1';
3046 # QEMU returns some flags multiple times, with '_', '.' or '-'
3047 # (e.g. lahf_lm and lahf-lm; sse4.2, sse4-2 and sse4_2; ...).
3048 # We only keep those with underscores, to match /proc/cpuinfo
3049 $prop =~ s/\.|-/_/g;
3050 $flags->{$prop} = 1;
3055 # force stop with 10 sec timeout and 'nocheck'
3056 # always stop, even if QMP failed
3057 vm_stop
(undef, $fakevmid, 1, 1, 10, 0, 1);
3061 return [ sort keys %$flags ];
3064 # We need to query QEMU twice, since KVM and TCG have different supported flags
3065 PVE
::QemuConfig-
>lock_config($fakevmid, sub {
3066 $flags->{tcg
} = eval { $query_supported_run_qemu->(0) };
3067 warn "warning: failed querying supported tcg flags: $@\n" if $@;
3069 if ($kvm_supported) {
3070 $flags->{kvm
} = eval { $query_supported_run_qemu->(1) };
3071 warn "warning: failed querying supported kvm flags: $@\n" if $@;
3078 # Understood CPU flags are written to a file at 'pve-qemu' compile time
3079 my $understood_cpu_flag_dir = "/usr/share/kvm";
3080 sub query_understood_cpu_flags
{
3081 my $arch = get_host_arch
();
3082 my $filepath = "$understood_cpu_flag_dir/recognized-CPUID-flags-$arch";
3084 die "Cannot query understood QEMU CPU flags for architecture: $arch (file not found)\n"
3087 my $raw = file_get_contents
($filepath);
3088 $raw =~ s/^\s+|\s+$//g;
3089 my @flags = split(/\s+/, $raw);
3094 sub config_to_command
{
3095 my ($storecfg, $vmid, $conf, $defaults, $forcemachine, $forcecpu) = @_;
3098 my $globalFlags = [];
3099 my $machineFlags = [];
3104 my $ostype = $conf->{ostype
};
3105 my $winversion = windows_version
($ostype);
3106 my $kvm = $conf->{kvm
};
3107 my $nodename = nodename
();
3109 my $arch = get_vm_arch
($conf);
3110 my $kvm_binary = get_command_for_arch
($arch);
3111 my $kvmver = kvm_user_version
($kvm_binary);
3113 if (!$kvmver || $kvmver !~ m/^(\d+)\.(\d+)/ || $1 < 3) {
3114 $kvmver //= "undefined";
3115 die "Detected old QEMU binary ('$kvmver', at least 3.0 is required)\n";
3118 my $add_pve_version = min_version
($kvmver, 4, 1);
3120 my $machine_type = get_vm_machine
($conf, $forcemachine, $arch, $add_pve_version);
3121 my $machine_version = extract_version
($machine_type, $kvmver);
3122 $kvm //= 1 if is_native
($arch);
3124 $machine_version =~ m/(\d+)\.(\d+)/;
3125 my ($machine_major, $machine_minor) = ($1, $2);
3127 if ($kvmver =~ m/^\d+\.\d+\.(\d+)/ && $1 >= 90) {
3128 warn "warning: Installed QEMU version ($kvmver) is a release candidate, ignoring version checks\n";
3129 } elsif (!min_version
($kvmver, $machine_major, $machine_minor)) {
3130 die "Installed QEMU version '$kvmver' is too old to run machine type '$machine_type',"
3131 ." please upgrade node '$nodename'\n"
3132 } elsif (!PVE
::QemuServer
::Machine
::can_run_pve_machine_version
($machine_version, $kvmver)) {
3133 my $max_pve_version = PVE
::QemuServer
::Machine
::get_pve_version
($machine_version);
3134 die "Installed qemu-server (max feature level for $machine_major.$machine_minor is"
3135 ." pve$max_pve_version) is too old to run machine type '$machine_type', please upgrade"
3136 ." node '$nodename'\n";
3139 # if a specific +pve version is required for a feature, use $version_guard
3140 # instead of min_version to allow machines to be run with the minimum
3142 my $required_pve_version = 0;
3143 my $version_guard = sub {
3144 my ($major, $minor, $pve) = @_;
3145 return 0 if !min_version
($machine_version, $major, $minor, $pve);
3146 my $max_pve = PVE
::QemuServer
::Machine
::get_pve_version
("$major.$minor");
3147 return 1 if min_version
($machine_version, $major, $minor, $max_pve+1);
3148 $required_pve_version = $pve if $pve && $pve > $required_pve_version;
3152 if ($kvm && !defined kvm_version
()) {
3153 die "KVM virtualisation configured, but not available. Either disable in VM configuration"
3154 ." or enable in BIOS.\n";
3157 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
3158 my $hotplug_features = parse_hotplug_features
(defined($conf->{hotplug
}) ?
$conf->{hotplug
} : '1');
3159 my $use_old_bios_files = undef;
3160 ($use_old_bios_files, $machine_type) = qemu_use_old_bios_files
($machine_type);
3162 my $cpuunits = defined($conf->{cpuunits
}) ?
3163 $conf->{cpuunits
} : $defaults->{cpuunits
};
3165 push @$cmd, $kvm_binary;
3167 push @$cmd, '-id', $vmid;
3169 my $vmname = $conf->{name
} || "vm$vmid";
3171 push @$cmd, '-name', $vmname;
3173 push @$cmd, '-no-shutdown';
3177 my $qmpsocket = PVE
::QemuServer
::Helpers
::qmp_socket
($vmid);
3178 push @$cmd, '-chardev', "socket,id=qmp,path=$qmpsocket,server,nowait";
3179 push @$cmd, '-mon', "chardev=qmp,mode=control";
3181 if (min_version
($machine_version, 2, 12)) {
3182 push @$cmd, '-chardev', "socket,id=qmp-event,path=/var/run/qmeventd.sock,reconnect=5";
3183 push @$cmd, '-mon', "chardev=qmp-event,mode=control";
3186 push @$cmd, '-pidfile' , PVE
::QemuServer
::Helpers
::pidfile_name
($vmid);
3188 push @$cmd, '-daemonize';
3190 if ($conf->{smbios1
}) {
3191 my $smbios_conf = parse_smbios1
($conf->{smbios1
});
3192 if ($smbios_conf->{base64
}) {
3193 # Do not pass base64 flag to qemu
3194 delete $smbios_conf->{base64
};
3195 my $smbios_string = "";
3196 foreach my $key (keys %$smbios_conf) {
3198 if ($key eq "uuid") {
3199 $value = $smbios_conf->{uuid
}
3201 $value = decode_base64
($smbios_conf->{$key});
3203 # qemu accepts any binary data, only commas need escaping by double comma
3205 $smbios_string .= "," . $key . "=" . $value if $value;
3207 push @$cmd, '-smbios', "type=1" . $smbios_string;
3209 push @$cmd, '-smbios', "type=1,$conf->{smbios1}";
3213 if ($conf->{bios
} && $conf->{bios
} eq 'ovmf') {
3214 my ($ovmf_code, $ovmf_vars) = get_ovmf_files
($arch);
3215 die "uefi base image '$ovmf_code' not found\n" if ! -f
$ovmf_code;
3217 my ($path, $format);
3218 if (my $efidisk = $conf->{efidisk0
}) {
3219 my $d = parse_drive
('efidisk0', $efidisk);
3220 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($d->{file
}, 1);
3221 $format = $d->{format
};
3223 $path = PVE
::Storage
::path
($storecfg, $d->{file
});
3224 if (!defined($format)) {
3225 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
3226 $format = qemu_img_format
($scfg, $volname);
3230 die "efidisk format must be specified\n"
3231 if !defined($format);
3234 warn "no efidisk configured! Using temporary efivars disk.\n";
3235 $path = "/tmp/$vmid-ovmf.fd";
3236 PVE
::Tools
::file_copy
($ovmf_vars, $path, -s
$ovmf_vars);
3242 if ($format eq 'raw' && $version_guard->(4, 1, 2)) {
3243 $size_str = ",size=" . (-s
$ovmf_vars);
3246 push @$cmd, '-drive', "if=pflash,unit=0,format=raw,readonly,file=$ovmf_code";
3247 push @$cmd, '-drive', "if=pflash,unit=1,format=$format,id=drive-efidisk0$size_str,file=$path";
3252 # we use different pcie-port hardware for qemu >= 4.0 for passthrough
3253 if (min_version
($machine_version, 4, 0)) {
3254 push @$devices, '-readconfig', '/usr/share/qemu-server/pve-q35-4.0.cfg';
3256 push @$devices, '-readconfig', '/usr/share/qemu-server/pve-q35.cfg';
3260 if ($conf->{vmgenid
}) {
3261 push @$devices, '-device', 'vmgenid,guid='.$conf->{vmgenid
};
3264 # add usb controllers
3265 my @usbcontrollers = PVE
::QemuServer
::USB
::get_usb_controllers
(
3266 $conf, $bridges, $arch, $machine_type, $usbdesc->{format
}, $MAX_USB_DEVICES);
3267 push @$devices, @usbcontrollers if @usbcontrollers;
3268 my $vga = parse_vga
($conf->{vga
});
3270 my $qxlnum = vga_conf_has_spice
($conf->{vga
});
3271 $vga->{type
} = 'qxl' if $qxlnum;
3273 if (!$vga->{type
}) {
3274 if ($arch eq 'aarch64') {
3275 $vga->{type
} = 'virtio';
3276 } elsif (min_version
($machine_version, 2, 9)) {
3277 $vga->{type
} = (!$winversion || $winversion >= 6) ?
'std' : 'cirrus';
3279 $vga->{type
} = ($winversion >= 6) ?
'std' : 'cirrus';
3283 # enable absolute mouse coordinates (needed by vnc)
3285 if (defined($conf->{tablet
})) {
3286 $tablet = $conf->{tablet
};
3288 $tablet = $defaults->{tablet
};
3289 $tablet = 0 if $qxlnum; # disable for spice because it is not needed
3290 $tablet = 0 if $vga->{type
} =~ m/^serial\d+$/; # disable if we use serial terminal (no vga card)
3294 push @$devices, '-device', print_tabletdevice_full
($conf, $arch) if $tablet;
3295 my $kbd = print_keyboarddevice_full
($conf, $arch);
3296 push @$devices, '-device', $kbd if defined($kbd);
3299 my $bootorder = device_bootorder
($conf);
3301 # host pci device passthrough
3302 my ($kvm_off, $gpu_passthrough, $legacy_igd) = PVE
::QemuServer
::PCI
::print_hostpci_devices
(
3303 $vmid, $conf, $devices, $vga, $winversion, $q35, $bridges, $arch, $machine_type, $bootorder);
3306 my $usb_dev_features = {};
3307 $usb_dev_features->{spice_usb3
} = 1 if min_version
($machine_version, 4, 0);
3309 my @usbdevices = PVE
::QemuServer
::USB
::get_usb_devices
(
3310 $conf, $usbdesc->{format
}, $MAX_USB_DEVICES, $usb_dev_features, $bootorder);
3311 push @$devices, @usbdevices if @usbdevices;
3314 for (my $i = 0; $i < $MAX_SERIAL_PORTS; $i++) {
3315 if (my $path = $conf->{"serial$i"}) {
3316 if ($path eq 'socket') {
3317 my $socket = "/var/run/qemu-server/${vmid}.serial$i";
3318 push @$devices, '-chardev', "socket,id=serial$i,path=$socket,server,nowait";
3319 # On aarch64, serial0 is the UART device. Qemu only allows
3320 # connecting UART devices via the '-serial' command line, as
3321 # the device has a fixed slot on the hardware...
3322 if ($arch eq 'aarch64' && $i == 0) {
3323 push @$devices, '-serial', "chardev:serial$i";
3325 push @$devices, '-device', "isa-serial,chardev=serial$i";
3328 die "no such serial device\n" if ! -c
$path;
3329 push @$devices, '-chardev', "tty,id=serial$i,path=$path";
3330 push @$devices, '-device', "isa-serial,chardev=serial$i";
3336 for (my $i = 0; $i < $MAX_PARALLEL_PORTS; $i++) {
3337 if (my $path = $conf->{"parallel$i"}) {
3338 die "no such parallel device\n" if ! -c
$path;
3339 my $devtype = $path =~ m!^/dev/usb/lp! ?
'tty' : 'parport';
3340 push @$devices, '-chardev', "$devtype,id=parallel$i,path=$path";
3341 push @$devices, '-device', "isa-parallel,chardev=parallel$i";
3345 if (min_version
($machine_version, 4, 0) && (my $audio = conf_has_audio
($conf))) {
3346 my $audiopciaddr = print_pci_addr
("audio0", $bridges, $arch, $machine_type);
3347 my $audio_devs = audio_devs
($audio, $audiopciaddr, $machine_version);
3348 push @$devices, @$audio_devs;
3352 $sockets = $conf->{smp
} if $conf->{smp
}; # old style - no longer iused
3353 $sockets = $conf->{sockets
} if $conf->{sockets
};
3355 my $cores = $conf->{cores
} || 1;
3357 my $maxcpus = $sockets * $cores;
3359 my $vcpus = $conf->{vcpus
} ?
$conf->{vcpus
} : $maxcpus;
3361 my $allowed_vcpus = $cpuinfo->{cpus
};
3363 die "MAX $allowed_vcpus vcpus allowed per VM on this node\n"
3364 if ($allowed_vcpus < $maxcpus);
3366 if($hotplug_features->{cpu
} && min_version
($machine_version, 2, 7)) {
3368 push @$cmd, '-smp', "1,sockets=$sockets,cores=$cores,maxcpus=$maxcpus";
3369 for (my $i = 2; $i <= $vcpus; $i++) {
3370 my $cpustr = print_cpu_device
($conf,$i);
3371 push @$cmd, '-device', $cpustr;
3376 push @$cmd, '-smp', "$vcpus,sockets=$sockets,cores=$cores,maxcpus=$maxcpus";
3378 push @$cmd, '-nodefaults';
3380 push @$cmd, '-boot', "menu=on,strict=on,reboot-timeout=1000,splash=/usr/share/qemu-server/bootsplash.jpg";
3382 push @$cmd, '-no-acpi' if defined($conf->{acpi
}) && $conf->{acpi
} == 0;
3384 push @$cmd, '-no-reboot' if defined($conf->{reboot
}) && $conf->{reboot
} == 0;
3386 if ($vga->{type
} && $vga->{type
} !~ m/^serial\d+$/ && $vga->{type
} ne 'none'){
3387 push @$devices, '-device', print_vga_device
(
3388 $conf, $vga, $arch, $machine_version, $machine_type, undef, $qxlnum, $bridges);
3389 my $socket = PVE
::QemuServer
::Helpers
::vnc_socket
($vmid);
3390 push @$cmd, '-vnc', "unix:$socket,password";
3392 push @$cmd, '-vga', 'none' if $vga->{type
} eq 'none';
3393 push @$cmd, '-nographic';
3397 my $tdf = defined($conf->{tdf
}) ?
$conf->{tdf
} : $defaults->{tdf
};
3398 my $useLocaltime = $conf->{localtime};
3400 if ($winversion >= 5) { # windows
3401 $useLocaltime = 1 if !defined($conf->{localtime});
3403 # use time drift fix when acpi is enabled
3404 if (!(defined($conf->{acpi
}) && $conf->{acpi
} == 0)) {
3405 $tdf = 1 if !defined($conf->{tdf
});
3409 if ($winversion >= 6) {
3410 push @$globalFlags, 'kvm-pit.lost_tick_policy=discard';
3411 push @$cmd, '-no-hpet';
3414 push @$rtcFlags, 'driftfix=slew' if $tdf;
3416 if ($conf->{startdate
} && $conf->{startdate
} ne 'now') {
3417 push @$rtcFlags, "base=$conf->{startdate}";
3418 } elsif ($useLocaltime) {
3419 push @$rtcFlags, 'base=localtime';
3423 push @$cmd, '-cpu', $forcecpu;
3425 push @$cmd, get_cpu_options
($conf, $arch, $kvm, $kvm_off, $machine_version, $winversion, $gpu_passthrough);
3428 PVE
::QemuServer
::Memory
::config
($conf, $vmid, $sockets, $cores, $defaults, $hotplug_features, $cmd);
3430 push @$cmd, '-S' if $conf->{freeze
};
3432 push @$cmd, '-k', $conf->{keyboard
} if defined($conf->{keyboard
});
3434 my $guest_agent = parse_guest_agent
($conf);
3436 if ($guest_agent->{enabled
}) {
3437 my $qgasocket = PVE
::QemuServer
::Helpers
::qmp_socket
($vmid, 1);
3438 push @$devices, '-chardev', "socket,path=$qgasocket,server,nowait,id=qga0";
3440 if (!$guest_agent->{type
} || $guest_agent->{type
} eq 'virtio') {
3441 my $pciaddr = print_pci_addr
("qga0", $bridges, $arch, $machine_type);
3442 push @$devices, '-device', "virtio-serial,id=qga0$pciaddr";
3443 push @$devices, '-device', 'virtserialport,chardev=qga0,name=org.qemu.guest_agent.0';
3444 } elsif ($guest_agent->{type
} eq 'isa') {
3445 push @$devices, '-device', "isa-serial,chardev=qga0";
3449 my $rng = $conf->{rng0
} ? parse_rng
($conf->{rng0
}) : undef;
3450 if ($rng && $version_guard->(4, 1, 2)) {
3451 check_rng_source
($rng->{source
});
3453 my $max_bytes = $rng->{max_bytes
} // $rng_fmt->{max_bytes
}->{default};
3454 my $period = $rng->{period
} // $rng_fmt->{period
}->{default};
3455 my $limiter_str = "";
3457 $limiter_str = ",max-bytes=$max_bytes,period=$period";
3460 my $rng_addr = print_pci_addr
("rng0", $bridges, $arch, $machine_type);
3461 push @$devices, '-object', "rng-random,filename=$rng->{source},id=rng0";
3462 push @$devices, '-device', "virtio-rng-pci,rng=rng0$limiter_str$rng_addr";
3470 for (my $i = 1; $i < $qxlnum; $i++){
3471 push @$devices, '-device', print_vga_device
(
3472 $conf, $vga, $arch, $machine_version, $machine_type, $i, $qxlnum, $bridges);
3475 # assume other OS works like Linux
3476 my ($ram, $vram) = ("134217728", "67108864");
3477 if ($vga->{memory
}) {
3478 $ram = PVE
::Tools
::convert_size
($qxlnum*4*$vga->{memory
}, 'mb' => 'b');
3479 $vram = PVE
::Tools
::convert_size
($qxlnum*2*$vga->{memory
}, 'mb' => 'b');
3481 push @$cmd, '-global', "qxl-vga.ram_size=$ram";
3482 push @$cmd, '-global', "qxl-vga.vram_size=$vram";
3486 my $pciaddr = print_pci_addr
("spice", $bridges, $arch, $machine_type);
3488 my $pfamily = PVE
::Tools
::get_host_address_family
($nodename);
3489 my @nodeaddrs = PVE
::Tools
::getaddrinfo_all
('localhost', family
=> $pfamily);
3490 die "failed to get an ip address of type $pfamily for 'localhost'\n" if !@nodeaddrs;
3492 push @$devices, '-device', "virtio-serial,id=spice$pciaddr";
3493 push @$devices, '-chardev', "spicevmc,id=vdagent,name=vdagent";
3494 push @$devices, '-device', "virtserialport,chardev=vdagent,name=com.redhat.spice.0";
3496 my $localhost = PVE
::Network
::addr_to_ip
($nodeaddrs[0]->{addr
});
3497 $spice_port = PVE
::Tools
::next_spice_port
($pfamily, $localhost);
3499 my $spice_enhancement_str = $conf->{spice_enhancements
} // '';
3500 my $spice_enhancement = parse_property_string
($spice_enhancements_fmt, $spice_enhancement_str);
3501 if ($spice_enhancement->{foldersharing
}) {
3502 push @$devices, '-chardev', "spiceport,id=foldershare,name=org.spice-space.webdav.0";
3503 push @$devices, '-device', "virtserialport,chardev=foldershare,name=org.spice-space.webdav.0";
3506 my $spice_opts = "tls-port=${spice_port},addr=$localhost,tls-ciphers=HIGH,seamless-migration=on";
3507 $spice_opts .= ",streaming-video=$spice_enhancement->{videostreaming}"
3508 if $spice_enhancement->{videostreaming
};
3510 push @$devices, '-spice', "$spice_opts";
3513 # enable balloon by default, unless explicitly disabled
3514 if (!defined($conf->{balloon
}) || $conf->{balloon
}) {
3515 $pciaddr = print_pci_addr
("balloon0", $bridges, $arch, $machine_type);
3516 push @$devices, '-device', "virtio-balloon-pci,id=balloon0$pciaddr";
3519 if ($conf->{watchdog
}) {
3520 my $wdopts = parse_watchdog
($conf->{watchdog
});
3521 $pciaddr = print_pci_addr
("watchdog", $bridges, $arch, $machine_type);
3522 my $watchdog = $wdopts->{model
} || 'i6300esb';
3523 push @$devices, '-device', "$watchdog$pciaddr";
3524 push @$devices, '-watchdog-action', $wdopts->{action
} if $wdopts->{action
};
3528 my $scsicontroller = {};
3529 my $ahcicontroller = {};
3530 my $scsihw = defined($conf->{scsihw
}) ?
$conf->{scsihw
} : $defaults->{scsihw
};
3532 # Add iscsi initiator name if available
3533 if (my $initiator = get_initiator_name
()) {
3534 push @$devices, '-iscsi', "initiator-name=$initiator";
3537 PVE
::QemuConfig-
>foreach_volume($conf, sub {
3538 my ($ds, $drive) = @_;
3540 if (PVE
::Storage
::parse_volume_id
($drive->{file
}, 1)) {
3541 push @$vollist, $drive->{file
};
3544 # ignore efidisk here, already added in bios/fw handling code above
3545 return if $drive->{interface
} eq 'efidisk';
3547 $use_virtio = 1 if $ds =~ m/^virtio/;
3549 $drive->{bootindex
} = $bootorder->{$ds} if $bootorder->{$ds};
3551 if ($drive->{interface
} eq 'virtio'){
3552 push @$cmd, '-object', "iothread,id=iothread-$ds" if $drive->{iothread
};
3555 if ($drive->{interface
} eq 'scsi') {
3557 my ($maxdev, $controller, $controller_prefix) = scsihw_infos
($conf, $drive);
3559 die "scsi$drive->{index}: machine version 4.1~pve2 or higher is required to use more than 14 SCSI disks\n"
3560 if $drive->{index} > 13 && !&$version_guard(4, 1, 2);
3562 $pciaddr = print_pci_addr
("$controller_prefix$controller", $bridges, $arch, $machine_type);
3563 my $scsihw_type = $scsihw =~ m/^virtio-scsi-single/ ?
"virtio-scsi-pci" : $scsihw;
3566 if($conf->{scsihw
} && $conf->{scsihw
} eq "virtio-scsi-single" && $drive->{iothread
}){
3567 $iothread .= ",iothread=iothread-$controller_prefix$controller";
3568 push @$cmd, '-object', "iothread,id=iothread-$controller_prefix$controller";
3569 } elsif ($drive->{iothread
}) {
3570 warn "iothread is only valid with virtio disk or virtio-scsi-single controller, ignoring\n";
3574 if($conf->{scsihw
} && $conf->{scsihw
} eq "virtio-scsi-single" && $drive->{queues
}){
3575 $queues = ",num_queues=$drive->{queues}";
3578 push @$devices, '-device', "$scsihw_type,id=$controller_prefix$controller$pciaddr$iothread$queues"
3579 if !$scsicontroller->{$controller};
3580 $scsicontroller->{$controller}=1;
3583 if ($drive->{interface
} eq 'sata') {
3584 my $controller = int($drive->{index} / $PVE::QemuServer
::Drive
::MAX_SATA_DISKS
);
3585 $pciaddr = print_pci_addr
("ahci$controller", $bridges, $arch, $machine_type);
3586 push @$devices, '-device', "ahci,id=ahci$controller,multifunction=on$pciaddr"
3587 if !$ahcicontroller->{$controller};
3588 $ahcicontroller->{$controller}=1;
3591 my $drive_cmd = print_drive_commandline_full
($storecfg, $vmid, $drive);
3592 $drive_cmd .= ',readonly' if PVE
::QemuConfig-
>is_template($conf);
3594 push @$devices, '-drive',$drive_cmd;
3595 push @$devices, '-device', print_drivedevice_full
(
3596 $storecfg, $conf, $vmid, $drive, $bridges, $arch, $machine_type);
3599 for (my $i = 0; $i < $MAX_NETS; $i++) {
3600 my $netname = "net$i";
3602 next if !$conf->{$netname};
3603 my $d = parse_net
($conf->{$netname});
3606 $use_virtio = 1 if $d->{model
} eq 'virtio';
3608 $d->{bootindex
} = $bootorder->{$netname} if $bootorder->{$netname};
3610 my $netdevfull = print_netdev_full
($vmid, $conf, $arch, $d, $netname);
3611 push @$devices, '-netdev', $netdevfull;
3613 my $netdevicefull = print_netdevice_full
(
3614 $vmid, $conf, $d, $netname, $bridges, $use_old_bios_files, $arch, $machine_type);
3616 push @$devices, '-device', $netdevicefull;
3619 if ($conf->{ivshmem
}) {
3620 my $ivshmem = parse_property_string
($ivshmem_fmt, $conf->{ivshmem
});
3624 $bus = print_pcie_addr
("ivshmem");
3626 $bus = print_pci_addr
("ivshmem", $bridges, $arch, $machine_type);
3629 my $ivshmem_name = $ivshmem->{name
} // $vmid;
3630 my $path = '/dev/shm/pve-shm-' . $ivshmem_name;
3632 push @$devices, '-device', "ivshmem-plain,memdev=ivshmem$bus,";
3633 push @$devices, '-object', "memory-backend-file,id=ivshmem,share=on,mem-path=$path"
3634 .",size=$ivshmem->{size}M";
3637 # pci.4 is nested in pci.1
3638 $bridges->{1} = 1 if $bridges->{4};
3642 if (min_version
($machine_version, 2, 3)) {
3647 $bridges->{3} = 1 if $scsihw =~ m/^virtio-scsi-single/;
3651 for my $k (sort {$b cmp $a} keys %$bridges) {
3652 next if $q35 && $k < 4; # q35.cfg already includes bridges up to 3
3655 if ($k == 2 && $legacy_igd) {
3658 $pciaddr = print_pci_addr
("pci.$k_name", undef, $arch, $machine_type);
3660 my $devstr = "pci-bridge,id=pci.$k,chassis_nr=$k$pciaddr";
3662 # add after -readconfig pve-q35.cfg
3663 splice @$devices, 2, 0, '-device', $devstr;
3665 unshift @$devices, '-device', $devstr if $k > 0;
3670 push @$machineFlags, 'accel=tcg';
3673 my $machine_type_min = $machine_type;
3674 if ($add_pve_version) {
3675 $machine_type_min =~ s/\+pve\d+$//;
3676 $machine_type_min .= "+pve$required_pve_version";
3678 push @$machineFlags, "type=${machine_type_min}";
3680 push @$cmd, @$devices;
3681 push @$cmd, '-rtc', join(',', @$rtcFlags) if scalar(@$rtcFlags);
3682 push @$cmd, '-machine', join(',', @$machineFlags) if scalar(@$machineFlags);
3683 push @$cmd, '-global', join(',', @$globalFlags) if scalar(@$globalFlags);
3685 if (my $vmstate = $conf->{vmstate
}) {
3686 my $statepath = PVE
::Storage
::path
($storecfg, $vmstate);
3687 push @$vollist, $vmstate;
3688 push @$cmd, '-loadstate', $statepath;
3689 print "activating and using '$vmstate' as vmstate\n";
3693 if ($conf->{args
}) {
3694 my $aa = PVE
::Tools
::split_args
($conf->{args
});
3698 return wantarray ?
($cmd, $vollist, $spice_port) : $cmd;
3701 sub check_rng_source
{
3704 # mostly relevant for /dev/hwrng, but doesn't hurt to check others too
3705 die "cannot create VirtIO RNG device: source file '$source' doesn't exist\n"
3708 my $rng_current = '/sys/devices/virtual/misc/hw_random/rng_current';
3709 if ($source eq '/dev/hwrng' && file_read_firstline
($rng_current) eq 'none') {
3710 # Needs to abort, otherwise QEMU crashes on first rng access. Note that rng_current cannot
3711 # be changed to 'none' manually, so once the VM is past this point, it's no longer an issue.
3712 die "Cannot start VM with passed-through RNG device: '/dev/hwrng' exists, but"
3713 ." '$rng_current' is set to 'none'. Ensure that a compatible hardware-RNG is attached"
3721 my $res = mon_cmd
($vmid, 'query-spice');
3723 return $res->{'tls-port'} || $res->{'port'} || die "no spice port\n";
3726 sub vm_devices_list
{
3729 my $res = mon_cmd
($vmid, 'query-pci');
3730 my $devices_to_check = [];
3732 foreach my $pcibus (@$res) {
3733 push @$devices_to_check, @{$pcibus->{devices
}},
3736 while (@$devices_to_check) {
3738 for my $d (@$devices_to_check) {
3739 $devices->{$d->{'qdev_id'}} = 1 if $d->{'qdev_id'};
3740 next if !$d->{'pci_bridge'};
3742 $devices->{$d->{'qdev_id'}} += scalar(@{$d->{'pci_bridge'}->{devices
}});
3743 push @$to_check, @{$d->{'pci_bridge'}->{devices
}};
3745 $devices_to_check = $to_check;
3748 my $resblock = mon_cmd
($vmid, 'query-block');
3749 foreach my $block (@$resblock) {
3750 if($block->{device
} =~ m/^drive-(\S+)/){
3755 my $resmice = mon_cmd
($vmid, 'query-mice');
3756 foreach my $mice (@$resmice) {
3757 if ($mice->{name
} eq 'QEMU HID Tablet') {
3758 $devices->{tablet
} = 1;
3763 # for usb devices there is no query-usb
3764 # but we can iterate over the entries in
3765 # qom-list path=/machine/peripheral
3766 my $resperipheral = mon_cmd
($vmid, 'qom-list', path
=> '/machine/peripheral');
3767 foreach my $per (@$resperipheral) {
3768 if ($per->{name
} =~ m/^usb\d+$/) {
3769 $devices->{$per->{name
}} = 1;
3777 my ($storecfg, $conf, $vmid, $deviceid, $device, $arch, $machine_type) = @_;
3779 my $q35 = PVE
::QemuServer
::Machine
::machine_type_is_q35
($conf);
3781 my $devices_list = vm_devices_list
($vmid);
3782 return 1 if defined($devices_list->{$deviceid});
3784 # add PCI bridge if we need it for the device
3785 qemu_add_pci_bridge
($storecfg, $conf, $vmid, $deviceid, $arch, $machine_type);
3787 if ($deviceid eq 'tablet') {
3789 qemu_deviceadd
($vmid, print_tabletdevice_full
($conf, $arch));
3791 } elsif ($deviceid eq 'keyboard') {
3793 qemu_deviceadd
($vmid, print_keyboarddevice_full
($conf, $arch));
3795 } elsif ($deviceid =~ m/^usb(\d+)$/) {
3797 die "usb hotplug currently not reliable\n";
3798 # since we can't reliably hot unplug all added usb devices and usb
3799 # passthrough breaks live migration we disable usb hotplugging for now
3800 #qemu_deviceadd($vmid, PVE::QemuServer::USB::print_usbdevice_full($conf, $deviceid, $device));
3802 } elsif ($deviceid =~ m/^(virtio)(\d+)$/) {
3804 qemu_iothread_add
($vmid, $deviceid, $device);
3806 qemu_driveadd
($storecfg, $vmid, $device);
3807 my $devicefull = print_drivedevice_full
($storecfg, $conf, $vmid, $device, undef, $arch, $machine_type);
3809 qemu_deviceadd
($vmid, $devicefull);
3810 eval { qemu_deviceaddverify
($vmid, $deviceid); };
3812 eval { qemu_drivedel
($vmid, $deviceid); };
3817 } elsif ($deviceid =~ m/^(virtioscsi|scsihw)(\d+)$/) {
3820 my $scsihw = defined($conf->{scsihw
}) ?
$conf->{scsihw
} : "lsi";
3821 my $pciaddr = print_pci_addr
($deviceid, undef, $arch, $machine_type);
3822 my $scsihw_type = $scsihw eq 'virtio-scsi-single' ?
"virtio-scsi-pci" : $scsihw;
3824 my $devicefull = "$scsihw_type,id=$deviceid$pciaddr";
3826 if($deviceid =~ m/^virtioscsi(\d+)$/ && $device->{iothread
}) {
3827 qemu_iothread_add
($vmid, $deviceid, $device);
3828 $devicefull .= ",iothread=iothread-$deviceid";
3831 if($deviceid =~ m/^virtioscsi(\d+)$/ && $device->{queues
}) {
3832 $devicefull .= ",num_queues=$device->{queues}";
3835 qemu_deviceadd
($vmid, $devicefull);
3836 qemu_deviceaddverify
($vmid, $deviceid);
3838 } elsif ($deviceid =~ m/^(scsi)(\d+)$/) {
3840 qemu_findorcreatescsihw
($storecfg,$conf, $vmid, $device, $arch, $machine_type);
3841 qemu_driveadd
($storecfg, $vmid, $device);
3843 my $devicefull = print_drivedevice_full
($storecfg, $conf, $vmid, $device, undef, $arch, $machine_type);
3844 eval { qemu_deviceadd
($vmid, $devicefull); };
3846 eval { qemu_drivedel
($vmid, $deviceid); };
3851 } elsif ($deviceid =~ m/^(net)(\d+)$/) {
3853 return if !qemu_netdevadd
($vmid, $conf, $arch, $device, $deviceid);
3855 my $machine_type = PVE
::QemuServer
::Machine
::qemu_machine_pxe
($vmid, $conf);
3856 my $use_old_bios_files = undef;
3857 ($use_old_bios_files, $machine_type) = qemu_use_old_bios_files
($machine_type);
3859 my $netdevicefull = print_netdevice_full
(
3860 $vmid, $conf, $device, $deviceid, undef, $use_old_bios_files, $arch, $machine_type);
3861 qemu_deviceadd
($vmid, $netdevicefull);
3863 qemu_deviceaddverify
($vmid, $deviceid);
3864 qemu_set_link_status
($vmid, $deviceid, !$device->{link_down
});
3867 eval { qemu_netdevdel
($vmid, $deviceid); };
3872 } elsif (!$q35 && $deviceid =~ m/^(pci\.)(\d+)$/) {
3875 my $pciaddr = print_pci_addr
($deviceid, undef, $arch, $machine_type);
3876 my $devicefull = "pci-bridge,id=pci.$bridgeid,chassis_nr=$bridgeid$pciaddr";
3878 qemu_deviceadd
($vmid, $devicefull);
3879 qemu_deviceaddverify
($vmid, $deviceid);
3882 die "can't hotplug device '$deviceid'\n";
3888 # fixme: this should raise exceptions on error!
3889 sub vm_deviceunplug
{
3890 my ($vmid, $conf, $deviceid) = @_;
3892 my $devices_list = vm_devices_list
($vmid);
3893 return 1 if !defined($devices_list->{$deviceid});
3895 my $bootdisks = PVE
::QemuServer
::Drive
::get_bootdisks
($conf);
3896 die "can't unplug bootdisk '$deviceid'\n" if grep {$_ eq $deviceid} @$bootdisks;
3898 if ($deviceid eq 'tablet' || $deviceid eq 'keyboard') {
3900 qemu_devicedel
($vmid, $deviceid);
3902 } elsif ($deviceid =~ m/^usb\d+$/) {
3904 die "usb hotplug currently not reliable\n";
3905 # when unplugging usb devices this way, there may be remaining usb
3906 # controllers/hubs so we disable it for now
3907 #qemu_devicedel($vmid, $deviceid);
3908 #qemu_devicedelverify($vmid, $deviceid);
3910 } elsif ($deviceid =~ m/^(virtio)(\d+)$/) {
3912 qemu_devicedel
($vmid, $deviceid);
3913 qemu_devicedelverify
($vmid, $deviceid);
3914 qemu_drivedel
($vmid, $deviceid);
3915 qemu_iothread_del
($conf, $vmid, $deviceid);
3917 } elsif ($deviceid =~ m/^(virtioscsi|scsihw)(\d+)$/) {
3919 qemu_devicedel
($vmid, $deviceid);
3920 qemu_devicedelverify
($vmid, $deviceid);
3921 qemu_iothread_del
($conf, $vmid, $deviceid);
3923 } elsif ($deviceid =~ m/^(scsi)(\d+)$/) {
3925 qemu_devicedel
($vmid, $deviceid);
3926 qemu_drivedel
($vmid, $deviceid);
3927 qemu_deletescsihw
($conf, $vmid, $deviceid);
3929 } elsif ($deviceid =~ m/^(net)(\d+)$/) {
3931 qemu_devicedel
($vmid, $deviceid);
3932 qemu_devicedelverify
($vmid, $deviceid);
3933 qemu_netdevdel
($vmid, $deviceid);
3936 die "can't unplug device '$deviceid'\n";
3942 sub qemu_deviceadd
{
3943 my ($vmid, $devicefull) = @_;
3945 $devicefull = "driver=".$devicefull;
3946 my %options = split(/[=,]/, $devicefull);
3948 mon_cmd
($vmid, "device_add" , %options);
3951 sub qemu_devicedel
{
3952 my ($vmid, $deviceid) = @_;
3954 my $ret = mon_cmd
($vmid, "device_del", id
=> $deviceid);
3957 sub qemu_iothread_add
{
3958 my($vmid, $deviceid, $device) = @_;
3960 if ($device->{iothread
}) {
3961 my $iothreads = vm_iothreads_list
($vmid);
3962 qemu_objectadd
($vmid, "iothread-$deviceid", "iothread") if !$iothreads->{"iothread-$deviceid"};
3966 sub qemu_iothread_del
{
3967 my($conf, $vmid, $deviceid) = @_;
3969 my $confid = $deviceid;
3970 if ($deviceid =~ m/^(?:virtioscsi|scsihw)(\d+)$/) {
3971 $confid = 'scsi' . $1;
3973 my $device = parse_drive
($confid, $conf->{$confid});
3974 if ($device->{iothread
}) {
3975 my $iothreads = vm_iothreads_list
($vmid);
3976 qemu_objectdel
($vmid, "iothread-$deviceid") if $iothreads->{"iothread-$deviceid"};
3980 sub qemu_objectadd
{
3981 my($vmid, $objectid, $qomtype) = @_;
3983 mon_cmd
($vmid, "object-add", id
=> $objectid, "qom-type" => $qomtype);
3988 sub qemu_objectdel
{
3989 my($vmid, $objectid) = @_;
3991 mon_cmd
($vmid, "object-del", id
=> $objectid);
3997 my ($storecfg, $vmid, $device) = @_;
3999 my $drive = print_drive_commandline_full
($storecfg, $vmid, $device);
4000 $drive =~ s/\\/\\\\/g;
4001 my $ret = PVE
::QemuServer
::Monitor
::hmp_cmd
($vmid, "drive_add auto \"$drive\"");
4003 # If the command succeeds qemu prints: "OK
"
4004 return 1 if $ret =~ m/OK/s;
4006 die "adding drive failed
: $ret\n";
4010 my($vmid, $deviceid) = @_;
4012 my $ret = PVE::QemuServer::Monitor::hmp_cmd($vmid, "drive_del drive-
$deviceid");
4015 return 1 if $ret eq "";
4017 # NB: device not found errors mean the drive was auto-deleted and we ignore the error
4018 return 1 if $ret =~ m/Device \'.*?\' not found/s;
4020 die "deleting drive
$deviceid failed
: $ret\n";
4023 sub qemu_deviceaddverify {
4024 my ($vmid, $deviceid) = @_;
4026 for (my $i = 0; $i <= 5; $i++) {
4027 my $devices_list = vm_devices_list($vmid);
4028 return 1 if defined($devices_list->{$deviceid});
4032 die "error on hotplug device
'$deviceid'\n";
4036 sub qemu_devicedelverify {
4037 my ($vmid, $deviceid) = @_;
4039 # need to verify that the device is correctly removed as device_del
4040 # is async and empty return is not reliable
4042 for (my $i = 0; $i <= 5; $i++) {
4043 my $devices_list = vm_devices_list($vmid);
4044 return 1 if !defined($devices_list->{$deviceid});
4048 die "error on hot-unplugging device
'$deviceid'\n";
4051 sub qemu_findorcreatescsihw {
4052 my ($storecfg, $conf, $vmid, $device, $arch, $machine_type) = @_;
4054 my ($maxdev, $controller, $controller_prefix) = scsihw_infos($conf, $device);
4056 my $scsihwid="$controller_prefix$controller";
4057 my $devices_list = vm_devices_list($vmid);
4059 if(!defined($devices_list->{$scsihwid})) {
4060 vm_deviceplug($storecfg, $conf, $vmid, $scsihwid, $device, $arch, $machine_type);
4066 sub qemu_deletescsihw {
4067 my ($conf, $vmid, $opt) = @_;
4069 my $device = parse_drive($opt, $conf->{$opt});
4071 if ($conf->{scsihw} && ($conf->{scsihw} eq 'virtio-scsi-single')) {
4072 vm_deviceunplug($vmid, $conf, "virtioscsi
$device->{index}");
4076 my ($maxdev, $controller, $controller_prefix) = scsihw_infos($conf, $device);
4078 my $devices_list = vm_devices_list($vmid);
4079 foreach my $opt (keys %{$devices_list}) {
4080 if (is_valid_drivename($opt)) {
4081 my $drive = parse_drive($opt, $conf->{$opt});
4082 if($drive->{interface} eq 'scsi' && $drive->{index} < (($maxdev-1)*($controller+1))) {
4088 my $scsihwid="scsihw
$controller";
4090 vm_deviceunplug($vmid, $conf, $scsihwid);
4095 sub qemu_add_pci_bridge {
4096 my ($storecfg, $conf, $vmid, $device, $arch, $machine_type) = @_;
4102 print_pci_addr($device, $bridges, $arch, $machine_type);
4104 while (my ($k, $v) = each %$bridges) {
4107 return 1 if !defined($bridgeid) || $bridgeid < 1;
4109 my $bridge = "pci
.$bridgeid";
4110 my $devices_list = vm_devices_list($vmid);
4112 if (!defined($devices_list->{$bridge})) {
4113 vm_deviceplug($storecfg, $conf, $vmid, $bridge, $arch, $machine_type);
4119 sub qemu_set_link_status {
4120 my ($vmid, $device, $up) = @_;
4122 mon_cmd($vmid, "set_link
", name => $device,
4123 up => $up ? JSON::true : JSON::false);
4126 sub qemu_netdevadd {
4127 my ($vmid, $conf, $arch, $device, $deviceid) = @_;
4129 my $netdev = print_netdev_full($vmid, $conf, $arch, $device, $deviceid, 1);
4130 my %options = split(/[=,]/, $netdev);
4132 if (defined(my $vhost = $options{vhost})) {
4133 $options{vhost} = JSON::boolean(PVE::JSONSchema::parse_boolean($vhost));
4136 if (defined(my $queues = $options{queues})) {
4137 $options{queues} = $queues + 0;
4140 mon_cmd($vmid, "netdev_add
", %options);
4144 sub qemu_netdevdel {
4145 my ($vmid, $deviceid) = @_;
4147 mon_cmd($vmid, "netdev_del
", id => $deviceid);
4150 sub qemu_usb_hotplug {
4151 my ($storecfg, $conf, $vmid, $deviceid, $device, $arch, $machine_type) = @_;
4155 # remove the old one first
4156 vm_deviceunplug($vmid, $conf, $deviceid);
4158 # check if xhci controller is necessary and available
4159 if ($device->{usb3}) {
4161 my $devicelist = vm_devices_list($vmid);
4163 if (!$devicelist->{xhci}) {
4164 my $pciaddr = print_pci_addr("xhci
", undef, $arch, $machine_type);
4165 qemu_deviceadd($vmid, "nec-usb-xhci
,id
=xhci
$pciaddr");
4168 my $d = parse_usb_device($device->{host});
4169 $d->{usb3} = $device->{usb3};
4172 vm_deviceplug($storecfg, $conf, $vmid, $deviceid, $d, $arch, $machine_type);
4175 sub qemu_cpu_hotplug {
4176 my ($vmid, $conf, $vcpus) = @_;
4178 my $machine_type = PVE::QemuServer::Machine::get_current_qemu_machine($vmid);
4181 $sockets = $conf->{smp} if $conf->{smp}; # old style - no longer iused
4182 $sockets = $conf->{sockets} if $conf->{sockets};
4183 my $cores = $conf->{cores} || 1;
4184 my $maxcpus = $sockets * $cores;
4186 $vcpus = $maxcpus if !$vcpus;
4188 die "you can
't add more vcpus than maxcpus\n"
4189 if $vcpus > $maxcpus;
4191 my $currentvcpus = $conf->{vcpus} || $maxcpus;
4193 if ($vcpus < $currentvcpus) {
4195 if (PVE::QemuServer::Machine::machine_version($machine_type, 2, 7)) {
4197 for (my $i = $currentvcpus; $i > $vcpus; $i--) {
4198 qemu_devicedel($vmid, "cpu$i");
4200 my $currentrunningvcpus = undef;
4202 $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4203 last if scalar(@{$currentrunningvcpus}) == $i-1;
4204 raise_param_exc({ vcpus => "error unplugging cpu$i" }) if $retry > 5;
4208 #update conf after each succesfull cpu unplug
4209 $conf->{vcpus} = scalar(@{$currentrunningvcpus});
4210 PVE::QemuConfig->write_config($vmid, $conf);
4213 die "cpu hot-unplugging requires qemu version 2.7 or higher\n";
4219 my $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4220 die "vcpus in running vm does not match its configuration\n"
4221 if scalar(@{$currentrunningvcpus}) != $currentvcpus;
4223 if (PVE::QemuServer::Machine::machine_version($machine_type, 2, 7)) {
4225 for (my $i = $currentvcpus+1; $i <= $vcpus; $i++) {
4226 my $cpustr = print_cpu_device($conf, $i);
4227 qemu_deviceadd($vmid, $cpustr);
4230 my $currentrunningvcpus = undef;
4232 $currentrunningvcpus = mon_cmd($vmid, "query-cpus-fast");
4233 last if scalar(@{$currentrunningvcpus}) == $i;
4234 raise_param_exc({ vcpus => "error hotplugging cpu$i" }) if $retry > 10;
4238 #update conf after each succesfull cpu hotplug
4239 $conf->{vcpus} = scalar(@{$currentrunningvcpus});
4240 PVE::QemuConfig->write_config($vmid, $conf);
4244 for (my $i = $currentvcpus; $i < $vcpus; $i++) {
4245 mon_cmd($vmid, "cpu-add", id => int($i));
4250 sub qemu_block_set_io_throttle {
4251 my ($vmid, $deviceid,
4252 $bps, $bps_rd, $bps_wr, $iops, $iops_rd, $iops_wr,
4253 $bps_max, $bps_rd_max, $bps_wr_max, $iops_max, $iops_rd_max, $iops_wr_max,
4254 $bps_max_length, $bps_rd_max_length, $bps_wr_max_length,
4255 $iops_max_length, $iops_rd_max_length, $iops_wr_max_length) = @_;
4257 return if !check_running($vmid) ;
4259 mon_cmd($vmid, "block_set_io_throttle", device => $deviceid,
4261 bps_rd => int($bps_rd),
4262 bps_wr => int($bps_wr),
4264 iops_rd => int($iops_rd),
4265 iops_wr => int($iops_wr),
4266 bps_max => int($bps_max),
4267 bps_rd_max => int($bps_rd_max),
4268 bps_wr_max => int($bps_wr_max),
4269 iops_max => int($iops_max),
4270 iops_rd_max => int($iops_rd_max),
4271 iops_wr_max => int($iops_wr_max),
4272 bps_max_length => int($bps_max_length),
4273 bps_rd_max_length => int($bps_rd_max_length),
4274 bps_wr_max_length => int($bps_wr_max_length),
4275 iops_max_length => int($iops_max_length),
4276 iops_rd_max_length => int($iops_rd_max_length),
4277 iops_wr_max_length => int($iops_wr_max_length),
4282 sub qemu_block_resize {
4283 my ($vmid, $deviceid, $storecfg, $volid, $size) = @_;
4285 my $running = check_running($vmid);
4287 $size = 0 if !PVE::Storage::volume_resize($storecfg, $volid, $size, $running);
4289 return if !$running;
4291 my $padding = (1024 - $size % 1024) % 1024;
4292 $size = $size + $padding;
4294 mon_cmd($vmid, "block_resize", device => $deviceid, size => int($size));
4298 sub qemu_volume_snapshot {
4299 my ($vmid, $deviceid, $storecfg, $volid, $snap) = @_;
4301 my $running = check_running($vmid);
4303 if ($running && do_snapshots_with_qemu($storecfg, $volid)){
4304 mon_cmd($vmid, 'blockdev-snapshot-internal-sync
', device => $deviceid, name => $snap);
4306 PVE::Storage::volume_snapshot($storecfg, $volid, $snap);
4310 sub qemu_volume_snapshot_delete {
4311 my ($vmid, $deviceid, $storecfg, $volid, $snap) = @_;
4313 my $running = check_running($vmid);
4318 my $conf = PVE::QemuConfig->load_config($vmid);
4319 PVE::QemuConfig->foreach_volume($conf, sub {
4320 my ($ds, $drive) = @_;
4321 $running = 1 if $drive->{file} eq $volid;
4325 if ($running && do_snapshots_with_qemu($storecfg, $volid)){
4326 mon_cmd($vmid, 'blockdev-snapshot-delete-internal-sync
', device => $deviceid, name => $snap);
4328 PVE::Storage::volume_snapshot_delete($storecfg, $volid, $snap, $running);
4332 sub set_migration_caps {
4335 my $qemu_support = eval { mon_cmd($vmid, "query-proxmox-support") };
4340 "auto-converge" => 1,
4342 "x-rdma-pin-all" => 0,
4345 "dirty-bitmaps" => $qemu_support->{'pbs-dirty-bitmap-migration
'} ? 1 : 0,
4348 my $supported_capabilities = mon_cmd($vmid, "query-migrate-capabilities");
4350 for my $supported_capability (@$supported_capabilities) {
4352 capability => $supported_capability->{capability},
4353 state => $enabled_cap->{$supported_capability->{capability}} ? JSON::true : JSON::false,
4357 mon_cmd($vmid, "migrate-set-capabilities", capabilities => $cap_ref);
4361 my ($conf, $func, @param) = @_;
4365 my $test_volid = sub {
4366 my ($key, $drive, $snapname) = @_;
4368 my $volid = $drive->{file};
4371 $volhash->{$volid}->{cdrom} //= 1;
4372 $volhash->{$volid}->{cdrom} = 0 if !drive_is_cdrom($drive);
4374 my $replicate = $drive->{replicate} // 1;
4375 $volhash->{$volid}->{replicate} //= 0;
4376 $volhash->{$volid}->{replicate} = 1 if $replicate;
4378 $volhash->{$volid}->{shared} //= 0;
4379 $volhash->{$volid}->{shared} = 1 if $drive->{shared};
4381 $volhash->{$volid}->{referenced_in_config} //= 0;
4382 $volhash->{$volid}->{referenced_in_config} = 1 if !defined($snapname);
4384 $volhash->{$volid}->{referenced_in_snapshot}->{$snapname} = 1
4385 if defined($snapname);
4387 my $size = $drive->{size};
4388 $volhash->{$volid}->{size} //= $size if $size;
4390 $volhash->{$volid}->{is_vmstate} //= 0;
4391 $volhash->{$volid}->{is_vmstate} = 1 if $key eq 'vmstate
';
4393 $volhash->{$volid}->{is_unused} //= 0;
4394 $volhash->{$volid}->{is_unused} = 1 if $key =~ /^unused\d+$/;
4397 my $include_opts = {
4398 extra_keys => ['vmstate
'],
4399 include_unused => 1,
4402 PVE::QemuConfig->foreach_volume_full($conf, $include_opts, $test_volid);
4403 foreach my $snapname (keys %{$conf->{snapshots}}) {
4404 my $snap = $conf->{snapshots}->{$snapname};
4405 PVE::QemuConfig->foreach_volume_full($snap, $include_opts, $test_volid, $snapname);
4408 foreach my $volid (keys %$volhash) {
4409 &$func($volid, $volhash->{$volid}, @param);
4413 my $fast_plug_option = {
4421 'vmstatestorage
' => 1,
4426 # hotplug changes in [PENDING]
4427 # $selection hash can be used to only apply specified options, for
4428 # example: { cores => 1 } (only apply changed 'cores
')
4429 # $errors ref is used to return error messages
4430 sub vmconfig_hotplug_pending {
4431 my ($vmid, $conf, $storecfg, $selection, $errors) = @_;
4433 my $defaults = load_defaults();
4434 my $arch = get_vm_arch($conf);
4435 my $machine_type = get_vm_machine($conf, undef, $arch);
4437 # commit values which do not have any impact on running VM first
4438 # Note: those option cannot raise errors, we we do not care about
4439 # $selection and always apply them.
4441 my $add_error = sub {
4442 my ($opt, $msg) = @_;
4443 $errors->{$opt} = "hotplug problem - $msg";
4447 foreach my $opt (keys %{$conf->{pending}}) { # add/change
4448 if ($fast_plug_option->{$opt}) {
4449 $conf->{$opt} = $conf->{pending}->{$opt};
4450 delete $conf->{pending}->{$opt};
4456 PVE::QemuConfig->write_config($vmid, $conf);
4459 my $hotplug_features = parse_hotplug_features(defined($conf->{hotplug}) ? $conf->{hotplug} : '1');
4461 my $cgroup = PVE::QemuServer::CGroup->new($vmid);
4462 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4463 foreach my $opt (sort keys %$pending_delete_hash) {
4464 next if $selection && !$selection->{$opt};
4465 my $force = $pending_delete_hash->{$opt}->{force};
4467 if ($opt eq 'hotplug
') {
4468 die "skip\n" if ($conf->{hotplug} =~ /memory/);
4469 } elsif ($opt eq 'tablet
') {
4470 die "skip\n" if !$hotplug_features->{usb};
4471 if ($defaults->{tablet}) {
4472 vm_deviceplug($storecfg, $conf, $vmid, 'tablet
', $arch, $machine_type);
4473 vm_deviceplug($storecfg, $conf, $vmid, 'keyboard
', $arch, $machine_type)
4474 if $arch eq 'aarch64
';
4476 vm_deviceunplug($vmid, $conf, 'tablet
');
4477 vm_deviceunplug($vmid, $conf, 'keyboard
') if $arch eq 'aarch64
';
4479 } elsif ($opt =~ m/^usb\d+/) {
4481 # since we cannot reliably hot unplug usb devices we are disabling it
4482 #die "skip\n" if !$hotplug_features->{usb} || $conf->{$opt} =~ m/spice/i;
4483 #vm_deviceunplug($vmid, $conf, $opt);
4484 } elsif ($opt eq 'vcpus
') {
4485 die "skip\n" if !$hotplug_features->{cpu};
4486 qemu_cpu_hotplug($vmid, $conf, undef);
4487 } elsif ($opt eq 'balloon
') {
4488 # enable balloon device is not hotpluggable
4489 die "skip\n" if defined($conf->{balloon}) && $conf->{balloon} == 0;
4490 # here we reset the ballooning value to memory
4491 my $balloon = $conf->{memory} || $defaults->{memory};
4492 mon_cmd($vmid, "balloon", value => $balloon*1024*1024);
4493 } elsif ($fast_plug_option->{$opt}) {
4495 } elsif ($opt =~ m/^net(\d+)$/) {
4496 die "skip\n" if !$hotplug_features->{network};
4497 vm_deviceunplug($vmid, $conf, $opt);
4498 } elsif (is_valid_drivename($opt)) {
4499 die "skip\n" if !$hotplug_features->{disk} || $opt =~ m/(ide|sata)(\d+)/;
4500 vm_deviceunplug($vmid, $conf, $opt);
4501 vmconfig_delete_or_detach_drive($vmid, $storecfg, $conf, $opt, $force);
4502 } elsif ($opt =~ m/^memory$/) {
4503 die "skip\n" if !$hotplug_features->{memory};
4504 PVE::QemuServer::Memory::qemu_memory_hotplug($vmid, $conf, $defaults, $opt);
4505 } elsif ($opt eq 'cpuunits
') {
4506 $cgroup->change_cpu_shares(undef, $defaults->{cpuunits});
4507 } elsif ($opt eq 'cpulimit
') {
4508 $cgroup->change_cpu_quota(-1, 100000);
4514 &$add_error($opt, $err) if $err ne "skip\n";
4516 delete $conf->{$opt};
4517 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4521 my ($apply_pending_cloudinit, $apply_pending_cloudinit_done);
4522 $apply_pending_cloudinit = sub {
4523 return if $apply_pending_cloudinit_done; # once is enough
4524 $apply_pending_cloudinit_done = 1; # once is enough
4526 my ($key, $value) = @_;
4528 my @cloudinit_opts = keys %$confdesc_cloudinit;
4529 foreach my $opt (keys %{$conf->{pending}}) {
4530 next if !grep { $_ eq $opt } @cloudinit_opts;
4531 $conf->{$opt} = delete $conf->{pending}->{$opt};
4534 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4535 foreach my $opt (sort keys %$pending_delete_hash) {
4536 next if !grep { $_ eq $opt } @cloudinit_opts;
4537 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4538 delete $conf->{$opt};
4541 my $new_conf = { %$conf };
4542 $new_conf->{$key} = $value;
4543 PVE::QemuServer::Cloudinit::generate_cloudinitconfig($new_conf, $vmid);
4546 foreach my $opt (keys %{$conf->{pending}}) {
4547 next if $selection && !$selection->{$opt};
4548 my $value = $conf->{pending}->{$opt};
4550 if ($opt eq 'hotplug
') {
4551 die "skip\n" if ($value =~ /memory/) || ($value !~ /memory/ && $conf->{hotplug} =~ /memory/);
4552 } elsif ($opt eq 'tablet
') {
4553 die "skip\n" if !$hotplug_features->{usb};
4555 vm_deviceplug($storecfg, $conf, $vmid, 'tablet
', $arch, $machine_type);
4556 vm_deviceplug($storecfg, $conf, $vmid, 'keyboard
', $arch, $machine_type)
4557 if $arch eq 'aarch64
';
4558 } elsif ($value == 0) {
4559 vm_deviceunplug($vmid, $conf, 'tablet
');
4560 vm_deviceunplug($vmid, $conf, 'keyboard
') if $arch eq 'aarch64
';
4562 } elsif ($opt =~ m/^usb\d+$/) {
4564 # since we cannot reliably hot unplug usb devices we disable it for now
4565 #die "skip\n" if !$hotplug_features->{usb} || $value =~ m/spice/i;
4566 #my $d = eval { parse_property_string($usbdesc->{format}, $value) };
4567 #die "skip\n" if !$d;
4568 #qemu_usb_hotplug($storecfg, $conf, $vmid, $opt, $d, $arch, $machine_type);
4569 } elsif ($opt eq 'vcpus
') {
4570 die "skip\n" if !$hotplug_features->{cpu};
4571 qemu_cpu_hotplug($vmid, $conf, $value);
4572 } elsif ($opt eq 'balloon
') {
4573 # enable/disable balloning device is not hotpluggable
4574 my $old_balloon_enabled = !!(!defined($conf->{balloon}) || $conf->{balloon});
4575 my $new_balloon_enabled = !!(!defined($conf->{pending}->{balloon}) || $conf->{pending}->{balloon});
4576 die "skip\n" if $old_balloon_enabled != $new_balloon_enabled;
4578 # allow manual ballooning if shares is set to zero
4579 if ((defined($conf->{shares}) && ($conf->{shares} == 0))) {
4580 my $balloon = $conf->{pending}->{balloon} || $conf->{memory} || $defaults->{memory};
4581 mon_cmd($vmid, "balloon", value => $balloon*1024*1024);
4583 } elsif ($opt =~ m/^net(\d+)$/) {
4584 # some changes can be done without hotplug
4585 vmconfig_update_net($storecfg, $conf, $hotplug_features->{network},
4586 $vmid, $opt, $value, $arch, $machine_type);
4587 } elsif (is_valid_drivename($opt)) {
4588 die "skip\n" if $opt eq 'efidisk0
';
4589 # some changes can be done without hotplug
4590 my $drive = parse_drive($opt, $value);
4591 if (drive_is_cloudinit($drive)) {
4592 &$apply_pending_cloudinit($opt, $value);
4594 vmconfig_update_disk($storecfg, $conf, $hotplug_features->{disk},
4595 $vmid, $opt, $value, $arch, $machine_type);
4596 } elsif ($opt =~ m/^memory$/) { #dimms
4597 die "skip\n" if !$hotplug_features->{memory};
4598 $value = PVE::QemuServer::Memory::qemu_memory_hotplug($vmid, $conf, $defaults, $opt, $value);
4599 } elsif ($opt eq 'cpuunits
') {
4600 $cgroup->change_cpu_shares($conf->{pending}->{$opt}, $defaults->{cpuunits});
4601 } elsif ($opt eq 'cpulimit
') {
4602 my $cpulimit = $conf->{pending}->{$opt} == 0 ? -1 : int($conf->{pending}->{$opt} * 100000);
4603 $cgroup->change_cpu_quota($cpulimit, 100000);
4605 die "skip\n"; # skip non-hot-pluggable options
4609 &$add_error($opt, $err) if $err ne "skip\n";
4611 $conf->{$opt} = $value;
4612 delete $conf->{pending}->{$opt};
4616 PVE::QemuConfig->write_config($vmid, $conf);
4619 sub try_deallocate_drive {
4620 my ($storecfg, $vmid, $conf, $key, $drive, $rpcenv, $authuser, $force) = @_;
4622 if (($force || $key =~ /^unused/) && !drive_is_cdrom($drive, 1)) {
4623 my $volid = $drive->{file};
4624 if (vm_is_volid_owner($storecfg, $vmid, $volid)) {
4625 my $sid = PVE::Storage::parse_volume_id($volid);
4626 $rpcenv->check($authuser, "/storage/$sid", ['Datastore
.AllocateSpace
']);
4628 # check if the disk is really unused
4629 die "unable to delete '$volid' - volume is still in use (snapshot?)\n"
4630 if PVE::QemuServer::Drive::is_volume_in_use($storecfg, $conf, $key, $volid);
4631 PVE::Storage::vdisk_free($storecfg, $volid);
4634 # If vm is not owner of this disk remove from config
4642 sub vmconfig_delete_or_detach_drive {
4643 my ($vmid, $storecfg, $conf, $opt, $force) = @_;
4645 my $drive = parse_drive($opt, $conf->{$opt});
4647 my $rpcenv = PVE::RPCEnvironment::get();
4648 my $authuser = $rpcenv->get_user();
4651 $rpcenv->check_vm_perm($authuser, $vmid, undef, ['VM
.Config
.Disk
']);
4652 try_deallocate_drive($storecfg, $vmid, $conf, $opt, $drive, $rpcenv, $authuser, $force);
4654 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $drive);
4660 sub vmconfig_apply_pending {
4661 my ($vmid, $conf, $storecfg, $errors) = @_;
4663 my $add_apply_error = sub {
4664 my ($opt, $msg) = @_;
4665 my $err_msg = "unable to apply pending change $opt : $msg";
4666 $errors->{$opt} = $err_msg;
4672 my $pending_delete_hash = PVE::QemuConfig->parse_pending_delete($conf->{pending}->{delete});
4673 foreach my $opt (sort keys %$pending_delete_hash) {
4674 my $force = $pending_delete_hash->{$opt}->{force};
4676 if ($opt =~ m/^unused/) {
4677 die "internal error";
4678 } elsif (defined($conf->{$opt}) && is_valid_drivename($opt)) {
4679 vmconfig_delete_or_detach_drive($vmid, $storecfg, $conf, $opt, $force);
4683 $add_apply_error->($opt, $err);
4685 PVE::QemuConfig->remove_from_pending_delete($conf, $opt);
4686 delete $conf->{$opt};
4690 PVE::QemuConfig->cleanup_pending($conf);
4692 foreach my $opt (keys %{$conf->{pending}}) { # add/change
4693 next if $opt eq 'delete'; # just to be sure
4695 if (defined($conf->{$opt}) && is_valid_drivename($opt)) {
4696 vmconfig_register_unused_drive($storecfg, $vmid, $conf, parse_drive($opt, $conf->{$opt}))
4700 $add_apply_error->($opt, $err);
4702 $conf->{$opt} = delete $conf->{pending}->{$opt};
4706 # write all changes at once to avoid unnecessary i/o
4707 PVE::QemuConfig->write_config($vmid, $conf);
4710 sub vmconfig_update_net {
4711 my ($storecfg, $conf, $hotplug, $vmid, $opt, $value, $arch, $machine_type) = @_;
4713 my $newnet = parse_net($value);
4715 if ($conf->{$opt}) {
4716 my $oldnet = parse_net($conf->{$opt});
4718 if (safe_string_ne($oldnet->{model}, $newnet->{model}) ||
4719 safe_string_ne($oldnet->{macaddr}, $newnet->{macaddr}) ||
4720 safe_num_ne($oldnet->{queues}, $newnet->{queues}) ||
4721 !($newnet->{bridge} && $oldnet->{bridge})) { # bridge/nat mode change
4723 # for non online change, we try to hot-unplug
4724 die "skip\n" if !$hotplug;
4725 vm_deviceunplug($vmid, $conf, $opt);
4728 die "internal error" if $opt !~ m/net(\d+)/;
4729 my $iface = "tap${vmid}i$1";
4731 if (safe_string_ne($oldnet->{bridge}, $newnet->{bridge}) ||
4732 safe_num_ne($oldnet->{tag}, $newnet->{tag}) ||
4733 safe_string_ne($oldnet->{trunks}, $newnet->{trunks}) ||
4734 safe_num_ne($oldnet->{firewall}, $newnet->{firewall})) {
4735 PVE::Network::tap_unplug($iface);
4738 PVE::Network::SDN::Zones::tap_plug($iface, $newnet->{bridge}, $newnet->{tag}, $newnet->{firewall}, $newnet->{trunks}, $newnet->{rate});
4740 PVE::Network::tap_plug($iface, $newnet->{bridge}, $newnet->{tag}, $newnet->{firewall}, $newnet->{trunks}, $newnet->{rate});
4742 } elsif (safe_num_ne($oldnet->{rate}, $newnet->{rate})) {
4743 # Rate can be applied on its own but any change above needs to
4744 # include the rate in tap_plug since OVS resets everything.
4745 PVE::Network::tap_rate_limit($iface, $newnet->{rate});
4748 if (safe_string_ne($oldnet->{link_down}, $newnet->{link_down})) {
4749 qemu_set_link_status($vmid, $opt, !$newnet->{link_down});
4757 vm_deviceplug($storecfg, $conf, $vmid, $opt, $newnet, $arch, $machine_type);
4763 sub vmconfig_update_disk {
4764 my ($storecfg, $conf, $hotplug, $vmid, $opt, $value, $arch, $machine_type) = @_;
4766 my $drive = parse_drive($opt, $value);
4768 if ($conf->{$opt} && (my $old_drive = parse_drive($opt, $conf->{$opt}))) {
4769 my $media = $drive->{media} || 'disk
';
4770 my $oldmedia = $old_drive->{media} || 'disk
';
4771 die "unable to change media type\n" if $media ne $oldmedia;
4773 if (!drive_is_cdrom($old_drive)) {
4775 if ($drive->{file} ne $old_drive->{file}) {
4777 die "skip\n" if !$hotplug;
4779 # unplug and register as unused
4780 vm_deviceunplug($vmid, $conf, $opt);
4781 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $old_drive)
4784 # update existing disk
4786 # skip non hotpluggable value
4787 if (safe_string_ne($drive->{discard}, $old_drive->{discard}) ||
4788 safe_string_ne($drive->{iothread}, $old_drive->{iothread}) ||
4789 safe_string_ne($drive->{queues}, $old_drive->{queues}) ||
4790 safe_string_ne($drive->{cache}, $old_drive->{cache}) ||
4791 safe_string_ne($drive->{ssd}, $old_drive->{ssd})) {
4796 if (safe_num_ne($drive->{mbps}, $old_drive->{mbps}) ||
4797 safe_num_ne($drive->{mbps_rd}, $old_drive->{mbps_rd}) ||
4798 safe_num_ne($drive->{mbps_wr}, $old_drive->{mbps_wr}) ||
4799 safe_num_ne($drive->{iops}, $old_drive->{iops}) ||
4800 safe_num_ne($drive->{iops_rd}, $old_drive->{iops_rd}) ||
4801 safe_num_ne($drive->{iops_wr}, $old_drive->{iops_wr}) ||
4802 safe_num_ne($drive->{mbps_max}, $old_drive->{mbps_max}) ||
4803 safe_num_ne($drive->{mbps_rd_max}, $old_drive->{mbps_rd_max}) ||
4804 safe_num_ne($drive->{mbps_wr_max}, $old_drive->{mbps_wr_max}) ||
4805 safe_num_ne($drive->{iops_max}, $old_drive->{iops_max}) ||
4806 safe_num_ne($drive->{iops_rd_max}, $old_drive->{iops_rd_max}) ||
4807 safe_num_ne($drive->{iops_wr_max}, $old_drive->{iops_wr_max}) ||
4808 safe_num_ne($drive->{bps_max_length}, $old_drive->{bps_max_length}) ||
4809 safe_num_ne($drive->{bps_rd_max_length}, $old_drive->{bps_rd_max_length}) ||
4810 safe_num_ne($drive->{bps_wr_max_length}, $old_drive->{bps_wr_max_length}) ||
4811 safe_num_ne($drive->{iops_max_length}, $old_drive->{iops_max_length}) ||
4812 safe_num_ne($drive->{iops_rd_max_length}, $old_drive->{iops_rd_max_length}) ||
4813 safe_num_ne($drive->{iops_wr_max_length}, $old_drive->{iops_wr_max_length})) {
4815 qemu_block_set_io_throttle(
4817 ($drive->{mbps} || 0)*1024*1024,
4818 ($drive->{mbps_rd} || 0)*1024*1024,
4819 ($drive->{mbps_wr} || 0)*1024*1024,
4820 $drive->{iops} || 0,
4821 $drive->{iops_rd} || 0,
4822 $drive->{iops_wr} || 0,
4823 ($drive->{mbps_max} || 0)*1024*1024,
4824 ($drive->{mbps_rd_max} || 0)*1024*1024,
4825 ($drive->{mbps_wr_max} || 0)*1024*1024,
4826 $drive->{iops_max} || 0,
4827 $drive->{iops_rd_max} || 0,
4828 $drive->{iops_wr_max} || 0,
4829 $drive->{bps_max_length} || 1,
4830 $drive->{bps_rd_max_length} || 1,
4831 $drive->{bps_wr_max_length} || 1,
4832 $drive->{iops_max_length} || 1,
4833 $drive->{iops_rd_max_length} || 1,
4834 $drive->{iops_wr_max_length} || 1,
4844 if ($drive->{file} eq 'none
') {
4845 mon_cmd($vmid, "eject", force => JSON::true, id => "$opt");
4846 if (drive_is_cloudinit($old_drive)) {
4847 vmconfig_register_unused_drive($storecfg, $vmid, $conf, $old_drive);
4850 my $path = get_iso_path($storecfg, $vmid, $drive->{file});
4852 # force eject if locked
4853 mon_cmd($vmid, "eject", force => JSON::true, id => "$opt");
4856 mon_cmd($vmid, "blockdev-change-medium",
4857 id => "$opt", filename => "$path");
4865 die "skip\n" if !$hotplug || $opt =~ m/(ide|sata)(\d+)/;
4867 PVE::Storage::activate_volumes($storecfg, [$drive->{file}]) if $drive->{file} !~ m|^/dev/.+|;
4868 vm_deviceplug($storecfg, $conf, $vmid, $opt, $drive, $arch, $machine_type);
4871 # called in locked context by incoming migration
4872 sub vm_migrate_get_nbd_disks {
4873 my ($storecfg, $conf, $replicated_volumes) = @_;
4875 my $local_volumes = {};
4876 PVE::QemuConfig->foreach_volume($conf, sub {
4877 my ($ds, $drive) = @_;
4879 return if drive_is_cdrom($drive);
4881 my $volid = $drive->{file};
4885 my ($storeid, $volname) = PVE::Storage::parse_volume_id($volid);
4887 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
4888 return if $scfg->{shared};
4890 # replicated disks re-use existing state via bitmap
4891 my $use_existing = $replicated_volumes->{$volid} ? 1 : 0;
4892 $local_volumes->{$ds} = [$volid, $storeid, $volname, $drive, $use_existing];
4894 return $local_volumes;
4897 # called in locked context by incoming migration
4898 sub vm_migrate_alloc_nbd_disks {
4899 my ($storecfg, $vmid, $source_volumes, $storagemap) = @_;
4904 foreach my $opt (sort keys %$source_volumes) {
4905 my ($volid, $storeid, $volname, $drive, $use_existing) = @{$source_volumes->{$opt}};
4907 if ($use_existing) {
4908 $nbd->{$opt}->{drivestr} = print_drive($drive);
4909 $nbd->{$opt}->{volid} = $volid;
4910 $nbd->{$opt}->{replicated} = 1;
4914 # If a remote storage is specified and the format of the original
4915 # volume is not available there, fall back to the default format.
4916 # Otherwise use the same format as the original.
4917 if (!$storagemap->{identity}) {
4918 $storeid = map_storage($storagemap, $storeid);
4919 my ($defFormat, $validFormats) = PVE::Storage::storage_default_format($storecfg, $storeid);
4920 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
4921 my $fileFormat = qemu_img_format($scfg, $volname);
4922 $format = (grep {$fileFormat eq $_} @{$validFormats}) ? $fileFormat : $defFormat;
4924 my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
4925 $format = qemu_img_format($scfg, $volname);
4928 my $size = $drive->{size} / 1024;
4929 my $newvolid = PVE::Storage::vdisk_alloc($storecfg, $storeid, $vmid, $format, undef, $size);
4930 my $newdrive = $drive;
4931 $newdrive->{format} = $format;
4932 $newdrive->{file} = $newvolid;
4933 my $drivestr = print_drive($newdrive);
4934 $nbd->{$opt}->{drivestr} = $drivestr;
4935 $nbd->{$opt}->{volid} = $newvolid;
4941 # see vm_start_nolock for parameters, additionally:
4943 # storagemap = parsed storage map for allocating NBD disks
4945 my ($storecfg, $vmid, $params, $migrate_opts) = @_;
4947 return PVE::QemuConfig->lock_config($vmid, sub {
4948 my $conf = PVE::QemuConfig->load_config($vmid, $migrate_opts->{migratedfrom});
4950 die "you can't start a vm
if it
's a template\n"
4951 if !$params->{skiptemplate} && PVE::QemuConfig->is_template($conf);
4953 my $has_suspended_lock = PVE::QemuConfig->has_lock($conf, 'suspended
');
4954 my $has_backup_lock = PVE::QemuConfig->has_lock($conf, 'backup
');
4956 my $running = check_running($vmid, undef, $migrate_opts->{migratedfrom});
4958 if ($has_backup_lock && $running) {
4959 # a backup is currently running, attempt to start the guest in the
4960 # existing QEMU instance
4961 return vm_resume($vmid);
4964 PVE::QemuConfig->check_lock($conf)
4965 if !($params->{skiplock} || $has_suspended_lock);
4967 $params->{resume} = $has_suspended_lock || defined($conf->{vmstate});
4969 die "VM $vmid already running\n" if $running;
4971 if (my $storagemap = $migrate_opts->{storagemap}) {
4972 my $replicated = $migrate_opts->{replicated_volumes};
4973 my $disks = vm_migrate_get_nbd_disks($storecfg, $conf, $replicated);
4974 $migrate_opts->{nbd} = vm_migrate_alloc_nbd_disks($storecfg, $vmid, $disks, $storagemap);
4976 foreach my $opt (keys %{$migrate_opts->{nbd}}) {
4977 $conf->{$opt} = $migrate_opts->{nbd}->{$opt}->{drivestr};
4981 return vm_start_nolock($storecfg, $vmid, $conf, $params, $migrate_opts);
4987 # statefile => 'tcp
', 'unix
' for migration or path/volid for RAM state
4988 # skiplock => 0/1, skip checking for config lock
4989 # skiptemplate => 0/1, skip checking whether VM is template
4990 # forcemachine => to force Qemu machine (rollback/migration)
4991 # forcecpu => a QEMU '-cpu
' argument string to override get_cpu_options
4992 # timeout => in seconds
4993 # paused => start VM in paused state (backup)
4994 # resume => resume from hibernation
4996 # nbd => volumes for NBD exports (vm_migrate_alloc_nbd_disks)
4997 # migratedfrom => source node
4998 # spice_ticket => used for spice migration, passed via tunnel/stdin
4999 # network => CIDR of migration network
5000 # type => secure/insecure - tunnel over encrypted connection or plain-text
5001 # nbd_proto_version => int, 0 for TCP, 1 for UNIX
5002 # replicated_volumes = which volids should be re-used with bitmaps for nbd migration
5003 sub vm_start_nolock {
5004 my ($storecfg, $vmid, $conf, $params, $migrate_opts) = @_;
5006 my $statefile = $params->{statefile};
5007 my $resume = $params->{resume};
5009 my $migratedfrom = $migrate_opts->{migratedfrom};
5010 my $migration_type = $migrate_opts->{type};
5014 # clean up leftover reboot request files
5015 eval { clear_reboot_request($vmid); };
5018 if (!$statefile && scalar(keys %{$conf->{pending}})) {
5019 vmconfig_apply_pending($vmid, $conf, $storecfg);
5020 $conf = PVE::QemuConfig->load_config($vmid); # update/reload
5023 PVE::QemuServer::Cloudinit::generate_cloudinitconfig($conf, $vmid);
5025 my $defaults = load_defaults();
5027 # set environment variable useful inside network script
5028 $ENV{PVE_MIGRATED_FROM} = $migratedfrom if $migratedfrom;
5030 PVE::GuestHelpers::exec_hookscript($conf, $vmid, 'pre-start
', 1);
5032 my $forcemachine = $params->{forcemachine};
5033 my $forcecpu = $params->{forcecpu};
5035 # enforce machine and CPU type on suspended vm to ensure HW compatibility
5036 $forcemachine = $conf->{runningmachine};
5037 $forcecpu = $conf->{runningcpu};
5038 print "Resuming suspended VM\n";
5041 my ($cmd, $vollist, $spice_port) =
5042 config_to_command($storecfg, $vmid, $conf, $defaults, $forcemachine, $forcecpu);
5045 my $get_migration_ip = sub {
5046 my ($nodename) = @_;
5048 return $migration_ip if defined($migration_ip);
5050 my $cidr = $migrate_opts->{network};
5052 if (!defined($cidr)) {
5053 my $dc_conf = PVE::Cluster::cfs_read_file('datacenter
.cfg
');
5054 $cidr = $dc_conf->{migration}->{network};
5057 if (defined($cidr)) {
5058 my $ips = PVE::Network::get_local_ip_from_cidr($cidr);
5060 die "could not get IP: no address configured on local " .
5061 "node for network '$cidr'\n" if scalar(@$ips) == 0;
5063 die "could not get IP: multiple addresses configured on local " .
5064 "node for network '$cidr'\n" if scalar(@$ips) > 1;
5066 $migration_ip = @$ips[0];
5069 $migration_ip = PVE::Cluster::remote_node_ip($nodename, 1)
5070 if !defined($migration_ip);
5072 return $migration_ip;
5077 if ($statefile eq 'tcp
') {
5078 my $localip = "localhost";
5079 my $datacenterconf = PVE::Cluster::cfs_read_file('datacenter
.cfg
');
5080 my $nodename = nodename();
5082 if (!defined($migration_type)) {
5083 if (defined($datacenterconf->{migration}->{type})) {
5084 $migration_type = $datacenterconf->{migration}->{type};
5086 $migration_type = 'secure
';
5090 if ($migration_type eq 'insecure
') {
5091 $localip = $get_migration_ip->($nodename);
5092 $localip = "[$localip]" if Net::IP::ip_is_ipv6($localip);
5095 my $pfamily = PVE::Tools::get_host_address_family($nodename);
5096 my $migrate_port = PVE::Tools::next_migrate_port($pfamily);
5097 $migrate_uri = "tcp:${localip}:${migrate_port}";
5098 push @$cmd, '-incoming
', $migrate_uri;
5101 } elsif ($statefile eq 'unix
') {
5102 # should be default for secure migrations as a ssh TCP forward
5103 # tunnel is not deterministic reliable ready and fails regurarly
5104 # to set up in time, so use UNIX socket forwards
5105 my $socket_addr = "/run/qemu-server/$vmid.migrate";
5106 unlink $socket_addr;
5108 $migrate_uri = "unix:$socket_addr";
5110 push @$cmd, '-incoming
', $migrate_uri;
5113 } elsif (-e $statefile) {
5114 push @$cmd, '-loadstate
', $statefile;
5116 my $statepath = PVE::Storage::path($storecfg, $statefile);
5117 push @$vollist, $statefile;
5118 push @$cmd, '-loadstate
', $statepath;
5120 } elsif ($params->{paused}) {
5125 for (my $i = 0; $i < $PVE::QemuServer::PCI::MAX_HOSTPCI_DEVICES; $i++) {
5126 my $d = parse_hostpci($conf->{"hostpci$i"});
5128 my $pcidevices = $d->{pciid};
5129 foreach my $pcidevice (@$pcidevices) {
5130 my $pciid = $pcidevice->{id};
5132 my $info = PVE::SysFSTools::pci_device_info("$pciid");
5133 die "IOMMU not present\n" if !PVE::SysFSTools::check_iommu_support();
5134 die "no pci device info for device '$pciid'\n" if !$info;
5137 my $uuid = PVE::SysFSTools::generate_mdev_uuid($vmid, $i);
5138 PVE::SysFSTools::pci_create_mdev_device($pciid, $uuid, $d->{mdev});
5140 die "can't unbind
/bind PCI group to VFIO
'$pciid'\n"
5141 if !PVE::SysFSTools::pci_dev_group_bind_to_vfio($pciid);
5142 die "can
't reset PCI device '$pciid'\n"
5143 if $info->{has_fl_reset} && !PVE::SysFSTools::pci_dev_reset($info);
5148 PVE::Storage::activate_volumes($storecfg, $vollist);
5151 run_command(['/bin/systemctl
', 'stop
', "$vmid.scope"],
5152 outfunc => sub {}, errfunc => sub {});
5154 # Issues with the above 'stop
' not being fully completed are extremely rare, a very low
5155 # timeout should be more than enough here...
5156 PVE::Systemd::wait_for_unit_removed("$vmid.scope", 5);
5158 my $cpuunits = defined($conf->{cpuunits}) ? $conf->{cpuunits}
5159 : $defaults->{cpuunits};
5161 my $start_timeout = $params->{timeout} // config_aware_timeout($conf, $resume);
5163 timeout => $statefile ? undef : $start_timeout,
5168 # when migrating, prefix QEMU output so other side can pick up any
5169 # errors that might occur and show the user
5170 if ($migratedfrom) {
5171 $run_params{quiet} = 1;
5172 $run_params{logfunc} = sub { print "QEMU: $_[0]\n" };
5176 Slice => 'qemu
.slice
',
5180 if (PVE::CGroup::cgroup_mode() == 2) {
5181 $properties{CPUWeight} = $cpuunits;
5183 $properties{CPUShares} = $cpuunits;
5186 if (my $cpulimit = $conf->{cpulimit}) {
5187 $properties{CPUQuota} = int($cpulimit * 100);
5189 $properties{timeout} = 10 if $statefile; # setting up the scope shoul be quick
5191 my $run_qemu = sub {
5192 PVE::Tools::run_fork sub {
5193 PVE::Systemd::enter_systemd_scope($vmid, "Proxmox VE VM $vmid", %properties);
5195 my $exitcode = run_command($cmd, %run_params);
5196 die "QEMU exited with code $exitcode\n" if $exitcode;
5200 if ($conf->{hugepages}) {
5203 my $hugepages_topology = PVE::QemuServer::Memory::hugepages_topology($conf);
5204 my $hugepages_host_topology = PVE::QemuServer::Memory::hugepages_host_topology();
5206 PVE::QemuServer::Memory::hugepages_mount();
5207 PVE::QemuServer::Memory::hugepages_allocate($hugepages_topology, $hugepages_host_topology);
5209 eval { $run_qemu->() };
5211 PVE::QemuServer::Memory::hugepages_reset($hugepages_host_topology)
5212 if !$conf->{keephugepages};
5216 PVE::QemuServer::Memory::hugepages_pre_deallocate($hugepages_topology)
5217 if !$conf->{keephugepages};
5219 eval { PVE::QemuServer::Memory::hugepages_update_locked($code); };
5222 eval { $run_qemu->() };
5226 # deactivate volumes if start fails
5227 eval { PVE::Storage::deactivate_volumes($storecfg, $vollist); };
5228 die "start failed: $err";
5231 print "migration listens on $migrate_uri\n" if $migrate_uri;
5232 $res->{migrate_uri} = $migrate_uri;
5234 if ($statefile && $statefile ne 'tcp
' && $statefile ne 'unix
') {
5235 eval { mon_cmd($vmid, "cont"); };
5239 #start nbd server for storage migration
5240 if (my $nbd = $migrate_opts->{nbd}) {
5241 my $nbd_protocol_version = $migrate_opts->{nbd_proto_version} // 0;
5243 my $migrate_storage_uri;
5244 # nbd_protocol_version > 0 for unix socket support
5245 if ($nbd_protocol_version > 0 && $migration_type eq 'secure
') {
5246 my $socket_path = "/run/qemu-server/$vmid\_nbd.migrate";
5247 mon_cmd($vmid, "nbd-server-start", addr => { type => 'unix
', data => { path => $socket_path } } );
5248 $migrate_storage_uri = "nbd:unix:$socket_path";
5250 my $nodename = nodename();
5251 my $localip = $get_migration_ip->($nodename);
5252 my $pfamily = PVE::Tools::get_host_address_family($nodename);
5253 my $storage_migrate_port = PVE::Tools::next_migrate_port($pfamily);
5255 mon_cmd($vmid, "nbd-server-start", addr => {
5258 host => "${localip}",
5259 port => "${storage_migrate_port}",
5262 $localip = "[$localip]" if Net::IP::ip_is_ipv6($localip);
5263 $migrate_storage_uri = "nbd:${localip}:${storage_migrate_port}";
5266 $res->{migrate_storage_uri} = $migrate_storage_uri;
5268 foreach my $opt (sort keys %$nbd) {
5269 my $drivestr = $nbd->{$opt}->{drivestr};
5270 my $volid = $nbd->{$opt}->{volid};
5271 mon_cmd($vmid, "nbd-server-add", device => "drive-$opt", writable => JSON::true );
5272 my $nbd_uri = "$migrate_storage_uri:exportname=drive-$opt";
5273 print "storage migration listens on $nbd_uri volume:$drivestr\n";
5274 print "re-using replicated volume: $opt - $volid\n"
5275 if $nbd->{$opt}->{replicated};
5277 $res->{drives}->{$opt} = $nbd->{$opt};
5278 $res->{drives}->{$opt}->{nbd_uri} = $nbd_uri;
5282 if ($migratedfrom) {
5284 set_migration_caps($vmid);
5289 print "spice listens on port $spice_port\n";
5290 $res->{spice_port} = $spice_port;
5291 if ($migrate_opts->{spice_ticket}) {
5292 mon_cmd($vmid, "set_password", protocol => 'spice
', password =>
5293 $migrate_opts->{spice_ticket});
5294 mon_cmd($vmid, "expire_password", protocol => 'spice
', time => "+30");
5299 mon_cmd($vmid, "balloon", value => $conf->{balloon}*1024*1024)
5300 if !$statefile && $conf->{balloon};
5302 foreach my $opt (keys %$conf) {
5303 next if $opt !~ m/^net\d+$/;
5304 my $nicconf = parse_net($conf->{$opt});
5305 qemu_set_link_status($vmid, $opt, 0) if $nicconf->{link_down};
5309 mon_cmd($vmid, 'qom-set
',
5310 path => "machine/peripheral/balloon0",
5311 property => "guest-stats-polling-interval",
5312 value => 2) if (!defined($conf->{balloon}) || $conf->{balloon});
5315 print "Resumed VM, removing state\n";
5316 if (my $vmstate = $conf->{vmstate}) {
5317 PVE::Storage::deactivate_volumes($storecfg, [$vmstate]);
5318 PVE::Storage::vdisk_free($storecfg, $vmstate);
5320 delete $conf->@{qw(lock vmstate runningmachine runningcpu)};
5321 PVE
::QemuConfig-
>write_config($vmid, $conf);
5324 PVE
::GuestHelpers
::exec_hookscript
($conf, $vmid, 'post-start');
5329 sub vm_commandline
{
5330 my ($storecfg, $vmid, $snapname) = @_;
5332 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5337 my $snapshot = $conf->{snapshots
}->{$snapname};
5338 die "snapshot '$snapname' does not exist\n" if !defined($snapshot);
5340 # check for machine or CPU overrides in snapshot
5341 $forcemachine = $snapshot->{runningmachine
};
5342 $forcecpu = $snapshot->{runningcpu
};
5344 $snapshot->{digest
} = $conf->{digest
}; # keep file digest for API
5349 my $defaults = load_defaults
();
5351 my $cmd = config_to_command
($storecfg, $vmid, $conf, $defaults,
5352 $forcemachine, $forcecpu);
5354 return PVE
::Tools
::cmd2string
($cmd);
5358 my ($vmid, $skiplock) = @_;
5360 PVE
::QemuConfig-
>lock_config($vmid, sub {
5362 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5364 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
5366 mon_cmd
($vmid, "system_reset");
5370 sub get_vm_volumes
{
5374 foreach_volid
($conf, sub {
5375 my ($volid, $attr) = @_;
5377 return if $volid =~ m
|^/|;
5379 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
5382 push @$vollist, $volid;
5388 sub vm_stop_cleanup
{
5389 my ($storecfg, $vmid, $conf, $keepActive, $apply_pending_changes) = @_;
5394 my $vollist = get_vm_volumes
($conf);
5395 PVE
::Storage
::deactivate_volumes
($storecfg, $vollist);
5398 foreach my $ext (qw(mon qmp pid vnc qga)) {
5399 unlink "/var/run/qemu-server/${vmid}.$ext";
5402 if ($conf->{ivshmem
}) {
5403 my $ivshmem = parse_property_string
($ivshmem_fmt, $conf->{ivshmem
});
5404 # just delete it for now, VMs which have this already open do not
5405 # are affected, but new VMs will get a separated one. If this
5406 # becomes an issue we either add some sort of ref-counting or just
5407 # add a "don't delete on stop" flag to the ivshmem format.
5408 unlink '/dev/shm/pve-shm-' . ($ivshmem->{name
} // $vmid);
5411 foreach my $key (keys %$conf) {
5412 next if $key !~ m/^hostpci(\d+)$/;
5413 my $hostpciindex = $1;
5414 my $d = parse_hostpci
($conf->{$key});
5415 my $uuid = PVE
::SysFSTools
::generate_mdev_uuid
($vmid, $hostpciindex);
5417 foreach my $pci (@{$d->{pciid
}}) {
5418 my $pciid = $pci->{id
};
5419 PVE
::SysFSTools
::pci_cleanup_mdev_device
($pciid, $uuid);
5423 vmconfig_apply_pending
($vmid, $conf, $storecfg) if $apply_pending_changes;
5425 warn $@ if $@; # avoid errors - just warn
5428 # call only in locked context
5430 my ($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive) = @_;
5432 my $pid = check_running
($vmid, $nocheck);
5437 $conf = PVE
::QemuConfig-
>load_config($vmid);
5438 PVE
::QemuConfig-
>check_lock($conf) if !$skiplock;
5439 if (!defined($timeout) && $shutdown && $conf->{startup
}) {
5440 my $opts = PVE
::JSONSchema
::pve_parse_startup_order
($conf->{startup
});
5441 $timeout = $opts->{down
} if $opts->{down
};
5443 PVE
::GuestHelpers
::exec_hookscript
($conf, $vmid, 'pre-stop');
5448 if (defined($conf) && get_qga_key
($conf, 'enabled')) {
5449 mon_cmd
($vmid, "guest-shutdown", timeout
=> $timeout);
5451 mon_cmd
($vmid, "system_powerdown");
5454 mon_cmd
($vmid, "quit");
5460 $timeout = 60 if !defined($timeout);
5463 while (($count < $timeout) && check_running
($vmid, $nocheck)) {
5468 if ($count >= $timeout) {
5470 warn "VM still running - terminating now with SIGTERM\n";
5473 die "VM quit/powerdown failed - got timeout\n";
5476 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 1) if $conf;
5480 if (!check_running
($vmid, $nocheck)) {
5481 warn "Unexpected: VM shutdown command failed, but VM not running anymore..\n";
5485 warn "VM quit/powerdown failed - terminating now with SIGTERM\n";
5488 die "VM quit/powerdown failed\n";
5496 while (($count < $timeout) && check_running
($vmid, $nocheck)) {
5501 if ($count >= $timeout) {
5502 warn "VM still running - terminating now with SIGKILL\n";
5507 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 1) if $conf;
5510 # Note: use $nocheck to skip tests if VM configuration file exists.
5511 # We need that when migration VMs to other nodes (files already moved)
5512 # Note: we set $keepActive in vzdump stop mode - volumes need to stay active
5514 my ($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive, $migratedfrom) = @_;
5516 $force = 1 if !defined($force) && !$shutdown;
5519 my $pid = check_running
($vmid, $nocheck, $migratedfrom);
5520 kill 15, $pid if $pid;
5521 my $conf = PVE
::QemuConfig-
>load_config($vmid, $migratedfrom);
5522 vm_stop_cleanup
($storecfg, $vmid, $conf, $keepActive, 0);
5526 PVE
::QemuConfig-
>lock_config($vmid, sub {
5527 _do_vm_stop
($storecfg, $vmid, $skiplock, $nocheck, $timeout, $shutdown, $force, $keepActive);
5532 my ($vmid, $timeout) = @_;
5534 PVE
::QemuConfig-
>lock_config($vmid, sub {
5537 # only reboot if running, as qmeventd starts it again on a stop event
5538 return if !check_running
($vmid);
5540 create_reboot_request
($vmid);
5542 my $storecfg = PVE
::Storage
::config
();
5543 _do_vm_stop
($storecfg, $vmid, undef, undef, $timeout, 1);
5547 # avoid that the next normal shutdown will be confused for a reboot
5548 clear_reboot_request
($vmid);
5554 # note: if using the statestorage parameter, the caller has to check privileges
5556 my ($vmid, $skiplock, $includestate, $statestorage) = @_;
5563 PVE
::QemuConfig-
>lock_config($vmid, sub {
5565 $conf = PVE
::QemuConfig-
>load_config($vmid);
5567 my $is_backing_up = PVE
::QemuConfig-
>has_lock($conf, 'backup');
5568 PVE
::QemuConfig-
>check_lock($conf)
5569 if !($skiplock || $is_backing_up);
5571 die "cannot suspend to disk during backup\n"
5572 if $is_backing_up && $includestate;
5574 if ($includestate) {
5575 $conf->{lock} = 'suspending';
5576 my $date = strftime
("%Y-%m-%d", localtime(time()));
5577 $storecfg = PVE
::Storage
::config
();
5578 if (!$statestorage) {
5579 $statestorage = find_vmstate_storage
($conf, $storecfg);
5580 # check permissions for the storage
5581 my $rpcenv = PVE
::RPCEnvironment
::get
();
5582 if ($rpcenv->{type
} ne 'cli') {
5583 my $authuser = $rpcenv->get_user();
5584 $rpcenv->check($authuser, "/storage/$statestorage", ['Datastore.AllocateSpace']);
5589 $vmstate = PVE
::QemuConfig-
>__snapshot_save_vmstate(
5590 $vmid, $conf, "suspend-$date", $storecfg, $statestorage, 1);
5591 $path = PVE
::Storage
::path
($storecfg, $vmstate);
5592 PVE
::QemuConfig-
>write_config($vmid, $conf);
5594 mon_cmd
($vmid, "stop");
5598 if ($includestate) {
5600 PVE
::Storage
::activate_volumes
($storecfg, [$vmstate]);
5603 mon_cmd
($vmid, "savevm-start", statefile
=> $path);
5605 my $state = mon_cmd
($vmid, "query-savevm");
5606 if (!$state->{status
}) {
5607 die "savevm not active\n";
5608 } elsif ($state->{status
} eq 'active') {
5611 } elsif ($state->{status
} eq 'completed') {
5612 print "State saved, quitting\n";
5614 } elsif ($state->{status
} eq 'failed' && $state->{error
}) {
5615 die "query-savevm failed with error '$state->{error}'\n"
5617 die "query-savevm returned status '$state->{status}'\n";
5623 PVE
::QemuConfig-
>lock_config($vmid, sub {
5624 $conf = PVE
::QemuConfig-
>load_config($vmid);
5626 # cleanup, but leave suspending lock, to indicate something went wrong
5628 mon_cmd
($vmid, "savevm-end");
5629 PVE
::Storage
::deactivate_volumes
($storecfg, [$vmstate]);
5630 PVE
::Storage
::vdisk_free
($storecfg, $vmstate);
5631 delete $conf->@{qw(vmstate runningmachine runningcpu)};
5632 PVE
::QemuConfig-
>write_config($vmid, $conf);
5638 die "lock changed unexpectedly\n"
5639 if !PVE
::QemuConfig-
>has_lock($conf, 'suspending');
5641 mon_cmd
($vmid, "quit");
5642 $conf->{lock} = 'suspended';
5643 PVE
::QemuConfig-
>write_config($vmid, $conf);
5649 my ($vmid, $skiplock, $nocheck) = @_;
5651 PVE
::QemuConfig-
>lock_config($vmid, sub {
5652 my $res = mon_cmd
($vmid, 'query-status');
5653 my $resume_cmd = 'cont';
5656 if ($res->{status
}) {
5657 return if $res->{status
} eq 'running'; # job done, go home
5658 $resume_cmd = 'system_wakeup' if $res->{status
} eq 'suspended';
5659 $reset = 1 if $res->{status
} eq 'shutdown';
5664 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5666 PVE
::QemuConfig-
>check_lock($conf)
5667 if !($skiplock || PVE
::QemuConfig-
>has_lock($conf, 'backup'));
5671 # required if a VM shuts down during a backup and we get a resume
5672 # request before the backup finishes for example
5673 mon_cmd
($vmid, "system_reset");
5675 mon_cmd
($vmid, $resume_cmd);
5680 my ($vmid, $skiplock, $key) = @_;
5682 PVE
::QemuConfig-
>lock_config($vmid, sub {
5684 my $conf = PVE
::QemuConfig-
>load_config($vmid);
5686 # there is no qmp command, so we use the human monitor command
5687 my $res = PVE
::QemuServer
::Monitor
::hmp_cmd
($vmid, "sendkey $key");
5688 die $res if $res ne '';
5692 # vzdump restore implementaion
5694 sub tar_archive_read_firstfile
{
5695 my $archive = shift;
5697 die "ERROR: file '$archive' does not exist\n" if ! -f
$archive;
5699 # try to detect archive type first
5700 my $pid = open (my $fh, '-|', 'tar', 'tf', $archive) ||
5701 die "unable to open file '$archive'\n";
5702 my $firstfile = <$fh>;
5706 die "ERROR: archive contaions no data\n" if !$firstfile;
5712 sub tar_restore_cleanup
{
5713 my ($storecfg, $statfile) = @_;
5715 print STDERR
"starting cleanup\n";
5717 if (my $fd = IO
::File-
>new($statfile, "r")) {
5718 while (defined(my $line = <$fd>)) {
5719 if ($line =~ m/vzdump:([^\s:]*):(\S+)$/) {
5722 if ($volid =~ m
|^/|) {
5723 unlink $volid || die 'unlink failed\n';
5725 PVE
::Storage
::vdisk_free
($storecfg, $volid);
5727 print STDERR
"temporary volume '$volid' sucessfuly removed\n";
5729 print STDERR
"unable to cleanup '$volid' - $@" if $@;
5731 print STDERR
"unable to parse line in statfile - $line";
5738 sub restore_file_archive
{
5739 my ($archive, $vmid, $user, $opts) = @_;
5741 return restore_vma_archive
($archive, $vmid, $user, $opts)
5744 my $info = PVE
::Storage
::archive_info
($archive);
5745 my $format = $opts->{format
} // $info->{format
};
5746 my $comp = $info->{compression
};
5748 # try to detect archive format
5749 if ($format eq 'tar') {
5750 return restore_tar_archive
($archive, $vmid, $user, $opts);
5752 return restore_vma_archive
($archive, $vmid, $user, $opts, $comp);
5756 # hepler to remove disks that will not be used after restore
5757 my $restore_cleanup_oldconf = sub {
5758 my ($storecfg, $vmid, $oldconf, $virtdev_hash) = @_;
5760 PVE
::QemuConfig-
>foreach_volume($oldconf, sub {
5761 my ($ds, $drive) = @_;
5763 return if drive_is_cdrom
($drive, 1);
5765 my $volid = $drive->{file
};
5766 return if !$volid || $volid =~ m
|^/|;
5768 my ($path, $owner) = PVE
::Storage
::path
($storecfg, $volid);
5769 return if !$path || !$owner || ($owner != $vmid);
5771 # Note: only delete disk we want to restore
5772 # other volumes will become unused
5773 if ($virtdev_hash->{$ds}) {
5774 eval { PVE
::Storage
::vdisk_free
($storecfg, $volid); };
5781 # delete vmstate files, after the restore we have no snapshots anymore
5782 foreach my $snapname (keys %{$oldconf->{snapshots
}}) {
5783 my $snap = $oldconf->{snapshots
}->{$snapname};
5784 if ($snap->{vmstate
}) {
5785 eval { PVE
::Storage
::vdisk_free
($storecfg, $snap->{vmstate
}); };
5793 # Helper to parse vzdump backup device hints
5795 # $rpcenv: Environment, used to ckeck storage permissions
5796 # $user: User ID, to check storage permissions
5797 # $storecfg: Storage configuration
5798 # $fh: the file handle for reading the configuration
5799 # $devinfo: should contain device sizes for all backu-up'ed devices
5800 # $options: backup options (pool, default storage)
5802 # Return: $virtdev_hash, updates $devinfo (add devname, virtdev, format, storeid)
5803 my $parse_backup_hints = sub {
5804 my ($rpcenv, $user, $storecfg, $fh, $devinfo, $options) = @_;
5806 my $virtdev_hash = {};
5808 while (defined(my $line = <$fh>)) {
5809 if ($line =~ m/^\#qmdump\#map:(\S+):(\S+):(\S*):(\S*):$/) {
5810 my ($virtdev, $devname, $storeid, $format) = ($1, $2, $3, $4);
5811 die "archive does not contain data for drive '$virtdev'\n"
5812 if !$devinfo->{$devname};
5814 if (defined($options->{storage
})) {
5815 $storeid = $options->{storage
} || 'local';
5816 } elsif (!$storeid) {
5819 $format = 'raw' if !$format;
5820 $devinfo->{$devname}->{devname
} = $devname;
5821 $devinfo->{$devname}->{virtdev
} = $virtdev;
5822 $devinfo->{$devname}->{format
} = $format;
5823 $devinfo->{$devname}->{storeid
} = $storeid;
5825 # check permission on storage
5826 my $pool = $options->{pool
}; # todo: do we need that?
5827 if ($user ne 'root@pam') {
5828 $rpcenv->check($user, "/storage/$storeid", ['Datastore.AllocateSpace']);
5831 $virtdev_hash->{$virtdev} = $devinfo->{$devname};
5832 } elsif ($line =~ m/^((?:ide|sata|scsi)\d+):\s*(.*)\s*$/) {
5834 my $drive = parse_drive
($virtdev, $2);
5835 if (drive_is_cloudinit
($drive)) {
5836 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($drive->{file
});
5837 $storeid = $options->{storage
} if defined ($options->{storage
});
5838 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
5839 my $format = qemu_img_format
($scfg, $volname); # has 'raw' fallback
5841 $virtdev_hash->{$virtdev} = {
5843 storeid
=> $storeid,
5844 size
=> PVE
::QemuServer
::Cloudinit
::CLOUDINIT_DISK_SIZE
,
5851 return $virtdev_hash;
5854 # Helper to allocate and activate all volumes required for a restore
5856 # $storecfg: Storage configuration
5857 # $virtdev_hash: as returned by parse_backup_hints()
5859 # Returns: { $virtdev => $volid }
5860 my $restore_allocate_devices = sub {
5861 my ($storecfg, $virtdev_hash, $vmid) = @_;
5864 foreach my $virtdev (sort keys %$virtdev_hash) {
5865 my $d = $virtdev_hash->{$virtdev};
5866 my $alloc_size = int(($d->{size
} + 1024 - 1)/1024);
5867 my $storeid = $d->{storeid
};
5868 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
5870 # test if requested format is supported
5871 my ($defFormat, $validFormats) = PVE
::Storage
::storage_default_format
($storecfg, $storeid);
5872 my $supported = grep { $_ eq $d->{format
} } @$validFormats;
5873 $d->{format
} = $defFormat if !$supported;
5876 if ($d->{is_cloudinit
}) {
5877 $name = "vm-$vmid-cloudinit";
5878 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
5879 if ($scfg->{path
}) {
5880 $name .= ".$d->{format}";
5884 my $volid = PVE
::Storage
::vdisk_alloc
(
5885 $storecfg, $storeid, $vmid, $d->{format
}, $name, $alloc_size);
5887 print STDERR
"new volume ID is '$volid'\n";
5888 $d->{volid
} = $volid;
5890 PVE
::Storage
::activate_volumes
($storecfg, [$volid]);
5892 $map->{$virtdev} = $volid;
5898 my $restore_update_config_line = sub {
5899 my ($cookie, $vmid, $map, $line, $unique) = @_;
5901 return '' if $line =~ m/^\#qmdump\#/;
5902 return '' if $line =~ m/^\#vzdump\#/;
5903 return '' if $line =~ m/^lock:/;
5904 return '' if $line =~ m/^unused\d+:/;
5905 return '' if $line =~ m/^parent:/;
5909 my $dc = PVE
::Cluster
::cfs_read_file
('datacenter.cfg');
5910 if (($line =~ m/^(vlan(\d+)):\s*(\S+)\s*$/)) {
5911 # try to convert old 1.X settings
5912 my ($id, $ind, $ethcfg) = ($1, $2, $3);
5913 foreach my $devconfig (PVE
::Tools
::split_list
($ethcfg)) {
5914 my ($model, $macaddr) = split(/\=/, $devconfig);
5915 $macaddr = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
}) if !$macaddr || $unique;
5918 bridge
=> "vmbr$ind",
5919 macaddr
=> $macaddr,
5921 my $netstr = print_net
($net);
5923 $res .= "net$cookie->{netcount}: $netstr\n";
5924 $cookie->{netcount
}++;
5926 } elsif (($line =~ m/^(net\d+):\s*(\S+)\s*$/) && $unique) {
5927 my ($id, $netstr) = ($1, $2);
5928 my $net = parse_net
($netstr);
5929 $net->{macaddr
} = PVE
::Tools
::random_ether_addr
($dc->{mac_prefix
}) if $net->{macaddr
};
5930 $netstr = print_net
($net);
5931 $res .= "$id: $netstr\n";
5932 } elsif ($line =~ m/^((ide|scsi|virtio|sata|efidisk)\d+):\s*(\S+)\s*$/) {
5935 my $di = parse_drive
($virtdev, $value);
5936 if (defined($di->{backup
}) && !$di->{backup
}) {
5938 } elsif ($map->{$virtdev}) {
5939 delete $di->{format
}; # format can change on restore
5940 $di->{file
} = $map->{$virtdev};
5941 $value = print_drive
($di);
5942 $res .= "$virtdev: $value\n";
5946 } elsif (($line =~ m/^vmgenid: (.*)/)) {
5948 if ($vmgenid ne '0') {
5949 # always generate a new vmgenid if there was a valid one setup
5950 $vmgenid = generate_uuid
();
5952 $res .= "vmgenid: $vmgenid\n";
5953 } elsif (($line =~ m/^(smbios1: )(.*)/) && $unique) {
5954 my ($uuid, $uuid_str);
5955 UUID
::generate
($uuid);
5956 UUID
::unparse
($uuid, $uuid_str);
5957 my $smbios1 = parse_smbios1
($2);
5958 $smbios1->{uuid
} = $uuid_str;
5959 $res .= $1.print_smbios1
($smbios1)."\n";
5967 my $restore_deactivate_volumes = sub {
5968 my ($storecfg, $devinfo) = @_;
5971 foreach my $devname (keys %$devinfo) {
5972 my $volid = $devinfo->{$devname}->{volid
};
5973 push @$vollist, $volid if $volid;
5976 PVE
::Storage
::deactivate_volumes
($storecfg, $vollist);
5979 my $restore_destroy_volumes = sub {
5980 my ($storecfg, $devinfo) = @_;
5982 foreach my $devname (keys %$devinfo) {
5983 my $volid = $devinfo->{$devname}->{volid
};
5986 if ($volid =~ m
|^/|) {
5987 unlink $volid || die 'unlink failed\n';
5989 PVE
::Storage
::vdisk_free
($storecfg, $volid);
5991 print STDERR
"temporary volume '$volid' sucessfuly removed\n";
5993 print STDERR
"unable to cleanup '$volid' - $@" if $@;
5998 my ($cfg, $vmid) = @_;
6000 my $info = PVE
::Storage
::vdisk_list
($cfg, undef, $vmid);
6002 my $volid_hash = {};
6003 foreach my $storeid (keys %$info) {
6004 foreach my $item (@{$info->{$storeid}}) {
6005 next if !($item->{volid
} && $item->{size
});
6006 $item->{path
} = PVE
::Storage
::path
($cfg, $item->{volid
});
6007 $volid_hash->{$item->{volid
}} = $item;
6014 sub update_disk_config
{
6015 my ($vmid, $conf, $volid_hash) = @_;
6018 my $prefix = "VM $vmid";
6020 # used and unused disks
6021 my $referenced = {};
6023 # Note: it is allowed to define multiple storages with same path (alias), so
6024 # we need to check both 'volid' and real 'path' (two different volid can point
6025 # to the same path).
6027 my $referencedpath = {};
6030 PVE
::QemuConfig-
>foreach_volume($conf, sub {
6031 my ($opt, $drive) = @_;
6033 my $volid = $drive->{file
};
6035 my $volume = $volid_hash->{$volid};
6037 # mark volid as "in-use" for next step
6038 $referenced->{$volid} = 1;
6039 if ($volume && (my $path = $volume->{path
})) {
6040 $referencedpath->{$path} = 1;
6043 return if drive_is_cdrom
($drive);
6046 my ($updated, $msg) = PVE
::QemuServer
::Drive
::update_disksize
($drive, $volume->{size
});
6047 if (defined($updated)) {
6049 $conf->{$opt} = print_drive
($updated);
6050 print "$prefix ($opt): $msg\n";
6054 # remove 'unusedX' entry if volume is used
6055 PVE
::QemuConfig-
>foreach_unused_volume($conf, sub {
6056 my ($opt, $drive) = @_;
6058 my $volid = $drive->{file
};
6062 $path = $volid_hash->{$volid}->{path
} if $volid_hash->{$volid};
6063 if ($referenced->{$volid} || ($path && $referencedpath->{$path})) {
6064 print "$prefix remove entry '$opt', its volume '$volid' is in use\n";
6066 delete $conf->{$opt};
6069 $referenced->{$volid} = 1;
6070 $referencedpath->{$path} = 1 if $path;
6073 foreach my $volid (sort keys %$volid_hash) {
6074 next if $volid =~ m/vm-$vmid-state-/;
6075 next if $referenced->{$volid};
6076 my $path = $volid_hash->{$volid}->{path
};
6077 next if !$path; # just to be sure
6078 next if $referencedpath->{$path};
6080 my $key = PVE
::QemuConfig-
>add_unused_volume($conf, $volid);
6081 print "$prefix add unreferenced volume '$volid' as '$key' to config\n";
6082 $referencedpath->{$path} = 1; # avoid to add more than once (aliases)
6089 my ($vmid, $nolock, $dryrun) = @_;
6091 my $cfg = PVE
::Storage
::config
();
6093 # FIXME: Remove once our RBD plugin can handle CT and VM on a single storage
6094 # see: https://pve.proxmox.com/pipermail/pve-devel/2018-July/032900.html
6095 foreach my $stor (keys %{$cfg->{ids
}}) {
6096 delete($cfg->{ids
}->{$stor}) if ! $cfg->{ids
}->{$stor}->{content
}->{images
};
6099 print "rescan volumes...\n";
6100 my $volid_hash = scan_volids
($cfg, $vmid);
6102 my $updatefn = sub {
6105 my $conf = PVE
::QemuConfig-
>load_config($vmid);
6107 PVE
::QemuConfig-
>check_lock($conf);
6110 foreach my $volid (keys %$volid_hash) {
6111 my $info = $volid_hash->{$volid};
6112 $vm_volids->{$volid} = $info if $info->{vmid
} && $info->{vmid
} == $vmid;
6115 my $changes = update_disk_config
($vmid, $conf, $vm_volids);
6117 PVE
::QemuConfig-
>write_config($vmid, $conf) if $changes && !$dryrun;
6120 if (defined($vmid)) {
6124 PVE
::QemuConfig-
>lock_config($vmid, $updatefn, $vmid);
6127 my $vmlist = config_list
();
6128 foreach my $vmid (keys %$vmlist) {
6132 PVE
::QemuConfig-
>lock_config($vmid, $updatefn, $vmid);
6138 sub restore_proxmox_backup_archive
{
6139 my ($archive, $vmid, $user, $options) = @_;
6141 my $storecfg = PVE
::Storage
::config
();
6143 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($archive);
6144 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
6146 my $fingerprint = $scfg->{fingerprint
};
6147 my $keyfile = PVE
::Storage
::PBSPlugin
::pbs_encryption_key_file_name
($storecfg, $storeid);
6149 my $repo = PVE
::PBSClient
::get_repository
($scfg);
6151 # This is only used for `pbs-restore`!
6152 my $password = PVE
::Storage
::PBSPlugin
::pbs_get_password
($scfg, $storeid);
6153 local $ENV{PBS_PASSWORD
} = $password;
6154 local $ENV{PBS_FINGERPRINT
} = $fingerprint if defined($fingerprint);
6156 my ($vtype, $pbs_backup_name, undef, undef, undef, undef, $format) =
6157 PVE
::Storage
::parse_volname
($storecfg, $archive);
6159 die "got unexpected vtype '$vtype'\n" if $vtype ne 'backup';
6161 die "got unexpected backup format '$format'\n" if $format ne 'pbs-vm';
6163 my $tmpdir = "/var/tmp/vzdumptmp$$";
6167 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6168 # disable interrupts (always do cleanups)
6172 local $SIG{HUP
} = sub { print STDERR
"got interrupt - ignored\n"; };
6174 # Note: $oldconf is undef if VM does not exists
6175 my $cfs_path = PVE
::QemuConfig-
>cfs_config_path($vmid);
6176 my $oldconf = PVE
::Cluster
::cfs_read_file
($cfs_path);
6177 my $new_conf_raw = '';
6179 my $rpcenv = PVE
::RPCEnvironment
::get
();
6188 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6190 my $cfgfn = "$tmpdir/qemu-server.conf";
6191 my $firewall_config_fn = "$tmpdir/fw.conf";
6192 my $index_fn = "$tmpdir/index.json";
6194 my $cmd = "restore";
6196 my $param = [$pbs_backup_name, "index.json", $index_fn];
6197 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6198 my $index = PVE
::Tools
::file_get_contents
($index_fn);
6199 $index = decode_json
($index);
6201 # print Dumper($index);
6202 foreach my $info (@{$index->{files
}}) {
6203 if ($info->{filename
} =~ m/^(drive-\S+).img.fidx$/) {
6205 if ($info->{size
} =~ m/^(\d+)$/) { # untaint size
6206 $devinfo->{$devname}->{size
} = $1;
6208 die "unable to parse file size in 'index.json' - got '$info->{size}'\n";
6213 my $is_qemu_server_backup = scalar(
6214 grep { $_->{filename
} eq 'qemu-server.conf.blob' } @{$index->{files
}}
6216 if (!$is_qemu_server_backup) {
6217 die "backup does not look like a qemu-server backup (missing 'qemu-server.conf' file)\n";
6219 my $has_firewall_config = scalar(grep { $_->{filename
} eq 'fw.conf.blob' } @{$index->{files
}});
6221 $param = [$pbs_backup_name, "qemu-server.conf", $cfgfn];
6222 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6224 if ($has_firewall_config) {
6225 $param = [$pbs_backup_name, "fw.conf", $firewall_config_fn];
6226 PVE
::Storage
::PBSPlugin
::run_raw_client_cmd
($scfg, $storeid, $cmd, $param);
6228 my $pve_firewall_dir = '/etc/pve/firewall';
6229 mkdir $pve_firewall_dir; # make sure the dir exists
6230 PVE
::Tools
::file_copy
($firewall_config_fn, "${pve_firewall_dir}/$vmid.fw");
6233 my $fh = IO
::File-
>new($cfgfn, "r") ||
6234 die "unable to read qemu-server.conf - $!\n";
6236 my $virtdev_hash = $parse_backup_hints->($rpcenv, $user, $storecfg, $fh, $devinfo, $options);
6238 # fixme: rate limit?
6240 # create empty/temp config
6241 PVE
::Tools
::file_set_contents
($conffile, "memory: 128\nlock: create");
6243 $restore_cleanup_oldconf->($storecfg, $vmid, $oldconf, $virtdev_hash) if $oldconf;
6246 my $map = $restore_allocate_devices->($storecfg, $virtdev_hash, $vmid);
6248 foreach my $virtdev (sort keys %$virtdev_hash) {
6249 my $d = $virtdev_hash->{$virtdev};
6250 next if $d->{is_cloudinit
}; # no need to restore cloudinit
6252 my $volid = $d->{volid
};
6254 my $path = PVE
::Storage
::path
($storecfg, $volid);
6256 # This is the ONLY user of the PBS_ env vars set on top of this function!
6257 my $pbs_restore_cmd = [
6258 '/usr/bin/pbs-restore',
6259 '--repository', $repo,
6261 "$d->{devname}.img.fidx",
6266 push @$pbs_restore_cmd, '--format', $d->{format
} if $d->{format
};
6267 push @$pbs_restore_cmd, '--keyfile', $keyfile if -e
$keyfile;
6269 if (PVE
::Storage
::volume_has_feature
($storecfg, 'sparseinit', $volid)) {
6270 push @$pbs_restore_cmd, '--skip-zero';
6273 my $dbg_cmdstring = PVE
::Tools
::cmd2string
($pbs_restore_cmd);
6274 print "restore proxmox backup image: $dbg_cmdstring\n";
6275 run_command
($pbs_restore_cmd);
6278 $fh->seek(0, 0) || die "seek failed - $!\n";
6280 my $cookie = { netcount
=> 0 };
6281 while (defined(my $line = <$fh>)) {
6282 $new_conf_raw .= $restore_update_config_line->(
6295 $restore_deactivate_volumes->($storecfg, $devinfo);
6300 $restore_destroy_volumes->($storecfg, $devinfo);
6304 PVE
::Tools
::file_set_contents
($conffile, $new_conf_raw);
6306 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6308 eval { rescan
($vmid, 1); };
6312 sub restore_vma_archive
{
6313 my ($archive, $vmid, $user, $opts, $comp) = @_;
6315 my $readfrom = $archive;
6317 my $cfg = PVE
::Storage
::config
();
6319 my $bwlimit = $opts->{bwlimit
};
6321 my $dbg_cmdstring = '';
6322 my $add_pipe = sub {
6324 push @$commands, $cmd;
6325 $dbg_cmdstring .= ' | ' if length($dbg_cmdstring);
6326 $dbg_cmdstring .= PVE
::Tools
::cmd2string
($cmd);
6331 if ($archive eq '-') {
6334 # If we use a backup from a PVE defined storage we also consider that
6335 # storage's rate limit:
6336 my (undef, $volid) = PVE
::Storage
::path_to_volume_id
($cfg, $archive);
6337 if (defined($volid)) {
6338 my ($sid, undef) = PVE
::Storage
::parse_volume_id
($volid);
6339 my $readlimit = PVE
::Storage
::get_bandwidth_limit
('restore', [$sid], $bwlimit);
6341 print STDERR
"applying read rate limit: $readlimit\n";
6342 my $cstream = ['cstream', '-t', $readlimit*1024, '--', $readfrom];
6343 $add_pipe->($cstream);
6349 my $info = PVE
::Storage
::decompressor_info
('vma', $comp);
6350 my $cmd = $info->{decompressor
};
6351 push @$cmd, $readfrom;
6355 my $tmpdir = "/var/tmp/vzdumptmp$$";
6358 # disable interrupts (always do cleanups)
6362 local $SIG{HUP
} = sub { warn "got interrupt - ignored\n"; };
6364 my $mapfifo = "/var/tmp/vzdumptmp$$.fifo";
6365 POSIX
::mkfifo
($mapfifo, 0600);
6367 my $openfifo = sub { open($fifofh, '>', $mapfifo) or die $! };
6369 $add_pipe->(['vma', 'extract', '-v', '-r', $mapfifo, $readfrom, $tmpdir]);
6376 my $rpcenv = PVE
::RPCEnvironment
::get
();
6378 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6380 # Note: $oldconf is undef if VM does not exist
6381 my $cfs_path = PVE
::QemuConfig-
>cfs_config_path($vmid);
6382 my $oldconf = PVE
::Cluster
::cfs_read_file
($cfs_path);
6383 my $new_conf_raw = '';
6387 my $print_devmap = sub {
6388 my $cfgfn = "$tmpdir/qemu-server.conf";
6390 # we can read the config - that is already extracted
6391 my $fh = IO
::File-
>new($cfgfn, "r") ||
6392 die "unable to read qemu-server.conf - $!\n";
6394 my $fwcfgfn = "$tmpdir/qemu-server.fw";
6396 my $pve_firewall_dir = '/etc/pve/firewall';
6397 mkdir $pve_firewall_dir; # make sure the dir exists
6398 PVE
::Tools
::file_copy
($fwcfgfn, "${pve_firewall_dir}/$vmid.fw");
6401 my $virtdev_hash = $parse_backup_hints->($rpcenv, $user, $cfg, $fh, $devinfo, $opts);
6403 foreach my $info (values %{$virtdev_hash}) {
6404 my $storeid = $info->{storeid
};
6405 next if defined($storage_limits{$storeid});
6407 my $limit = PVE
::Storage
::get_bandwidth_limit
('restore', [$storeid], $bwlimit) // 0;
6408 print STDERR
"rate limit for storage $storeid: $limit KiB/s\n" if $limit;
6409 $storage_limits{$storeid} = $limit * 1024;
6412 foreach my $devname (keys %$devinfo) {
6413 die "found no device mapping information for device '$devname'\n"
6414 if !$devinfo->{$devname}->{virtdev
};
6417 # create empty/temp config
6419 PVE
::Tools
::file_set_contents
($conffile, "memory: 128\n");
6420 $restore_cleanup_oldconf->($cfg, $vmid, $oldconf, $virtdev_hash);
6424 my $map = $restore_allocate_devices->($cfg, $virtdev_hash, $vmid);
6426 # print restore information to $fifofh
6427 foreach my $virtdev (sort keys %$virtdev_hash) {
6428 my $d = $virtdev_hash->{$virtdev};
6429 next if $d->{is_cloudinit
}; # no need to restore cloudinit
6431 my $storeid = $d->{storeid
};
6432 my $volid = $d->{volid
};
6435 if (my $limit = $storage_limits{$storeid}) {
6436 $map_opts .= "throttling.bps=$limit:throttling.group=$storeid:";
6439 my $write_zeros = 1;
6440 if (PVE
::Storage
::volume_has_feature
($cfg, 'sparseinit', $volid)) {
6444 my $path = PVE
::Storage
::path
($cfg, $volid);
6446 print $fifofh "${map_opts}format=$d->{format}:${write_zeros}:$d->{devname}=$path\n";
6448 print "map '$d->{devname}' to '$path' (write zeros = ${write_zeros})\n";
6451 $fh->seek(0, 0) || die "seek failed - $!\n";
6453 my $cookie = { netcount
=> 0 };
6454 while (defined(my $line = <$fh>)) {
6455 $new_conf_raw .= $restore_update_config_line->(
6473 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6474 local $SIG{ALRM
} = sub { die "got timeout\n"; };
6476 $oldtimeout = alarm($timeout);
6483 if ($line =~ m/^DEV:\sdev_id=(\d+)\ssize:\s(\d+)\sdevname:\s(\S+)$/) {
6484 my ($dev_id, $size, $devname) = ($1, $2, $3);
6485 $devinfo->{$devname} = { size
=> $size, dev_id
=> $dev_id };
6486 } elsif ($line =~ m/^CTIME: /) {
6487 # we correctly received the vma config, so we can disable
6488 # the timeout now for disk allocation (set to 10 minutes, so
6489 # that we always timeout if something goes wrong)
6492 print $fifofh "done\n";
6493 my $tmp = $oldtimeout || 0;
6494 $oldtimeout = undef;
6501 print "restore vma archive: $dbg_cmdstring\n";
6502 run_command
($commands, input
=> $input, outfunc
=> $parser, afterfork
=> $openfifo);
6506 alarm($oldtimeout) if $oldtimeout;
6508 $restore_deactivate_volumes->($cfg, $devinfo);
6510 close($fifofh) if $fifofh;
6515 $restore_destroy_volumes->($cfg, $devinfo);
6519 PVE
::Tools
::file_set_contents
($conffile, $new_conf_raw);
6521 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6523 eval { rescan
($vmid, 1); };
6527 sub restore_tar_archive
{
6528 my ($archive, $vmid, $user, $opts) = @_;
6530 if ($archive ne '-') {
6531 my $firstfile = tar_archive_read_firstfile
($archive);
6532 die "ERROR: file '$archive' does not look like a QemuServer vzdump backup\n"
6533 if $firstfile ne 'qemu-server.conf';
6536 my $storecfg = PVE
::Storage
::config
();
6538 # avoid zombie disks when restoring over an existing VM -> cleanup first
6539 # pass keep_empty_config=1 to keep the config (thus VMID) reserved for us
6540 # skiplock=1 because qmrestore has set the 'create' lock itself already
6541 my $vmcfgfn = PVE
::QemuConfig-
>config_file($vmid);
6542 destroy_vm
($storecfg, $vmid, 1, { lock => 'restore' }) if -f
$vmcfgfn;
6544 my $tocmd = "/usr/lib/qemu-server/qmextract";
6546 $tocmd .= " --storage " . PVE
::Tools
::shellquote
($opts->{storage
}) if $opts->{storage
};
6547 $tocmd .= " --pool " . PVE
::Tools
::shellquote
($opts->{pool
}) if $opts->{pool
};
6548 $tocmd .= ' --prealloc' if $opts->{prealloc
};
6549 $tocmd .= ' --info' if $opts->{info
};
6551 # tar option "xf" does not autodetect compression when read from STDIN,
6552 # so we pipe to zcat
6553 my $cmd = "zcat -f|tar xf " . PVE
::Tools
::shellquote
($archive) . " " .
6554 PVE
::Tools
::shellquote
("--to-command=$tocmd");
6556 my $tmpdir = "/var/tmp/vzdumptmp$$";
6559 local $ENV{VZDUMP_TMPDIR
} = $tmpdir;
6560 local $ENV{VZDUMP_VMID
} = $vmid;
6561 local $ENV{VZDUMP_USER
} = $user;
6563 my $conffile = PVE
::QemuConfig-
>config_file($vmid);
6564 my $new_conf_raw = '';
6566 # disable interrupts (always do cleanups)
6570 local $SIG{HUP
} = sub { print STDERR
"got interrupt - ignored\n"; };
6578 local $SIG{PIPE
} = sub { die "interrupted by signal\n"; };
6580 if ($archive eq '-') {
6581 print "extracting archive from STDIN\n";
6582 run_command
($cmd, input
=> "<&STDIN");
6584 print "extracting archive '$archive'\n";
6588 return if $opts->{info
};
6592 my $statfile = "$tmpdir/qmrestore.stat";
6593 if (my $fd = IO
::File-
>new($statfile, "r")) {
6594 while (defined (my $line = <$fd>)) {
6595 if ($line =~ m/vzdump:([^\s:]*):(\S+)$/) {
6596 $map->{$1} = $2 if $1;
6598 print STDERR
"unable to parse line in statfile - $line\n";
6604 my $confsrc = "$tmpdir/qemu-server.conf";
6606 my $srcfd = IO
::File-
>new($confsrc, "r") || die "unable to open file '$confsrc'\n";
6608 my $cookie = { netcount
=> 0 };
6609 while (defined (my $line = <$srcfd>)) {
6610 $new_conf_raw .= $restore_update_config_line->(
6622 tar_restore_cleanup
($storecfg, "$tmpdir/qmrestore.stat") if !$opts->{info
};
6628 PVE
::Tools
::file_set_contents
($conffile, $new_conf_raw);
6630 PVE
::Cluster
::cfs_update
(); # make sure we read new file
6632 eval { rescan
($vmid, 1); };
6636 sub foreach_storage_used_by_vm
{
6637 my ($conf, $func) = @_;
6641 PVE
::QemuConfig-
>foreach_volume($conf, sub {
6642 my ($ds, $drive) = @_;
6643 return if drive_is_cdrom
($drive);
6645 my $volid = $drive->{file
};
6647 my ($sid, $volname) = PVE
::Storage
::parse_volume_id
($volid, 1);
6648 $sidhash->{$sid} = $sid if $sid;
6651 foreach my $sid (sort keys %$sidhash) {
6656 my $qemu_snap_storage = {
6659 sub do_snapshots_with_qemu
{
6660 my ($storecfg, $volid) = @_;
6662 my $storage_name = PVE
::Storage
::parse_volume_id
($volid);
6663 my $scfg = $storecfg->{ids
}->{$storage_name};
6664 die "could not find storage '$storage_name'\n" if !defined($scfg);
6666 if ($qemu_snap_storage->{$scfg->{type
}} && !$scfg->{krbd
}){
6670 if ($volid =~ m/\.(qcow2|qed)$/){
6677 sub qga_check_running
{
6678 my ($vmid, $nowarn) = @_;
6680 eval { mon_cmd
($vmid, "guest-ping", timeout
=> 3); };
6682 warn "Qemu Guest Agent is not running - $@" if !$nowarn;
6688 sub template_create
{
6689 my ($vmid, $conf, $disk) = @_;
6691 my $storecfg = PVE
::Storage
::config
();
6693 PVE
::QemuConfig-
>foreach_volume($conf, sub {
6694 my ($ds, $drive) = @_;
6696 return if drive_is_cdrom
($drive);
6697 return if $disk && $ds ne $disk;
6699 my $volid = $drive->{file
};
6700 return if !PVE
::Storage
::volume_has_feature
($storecfg, 'template', $volid);
6702 my $voliddst = PVE
::Storage
::vdisk_create_base
($storecfg, $volid);
6703 $drive->{file
} = $voliddst;
6704 $conf->{$ds} = print_drive
($drive);
6705 PVE
::QemuConfig-
>write_config($vmid, $conf);
6709 sub convert_iscsi_path
{
6712 if ($path =~ m
|^iscsi
://([^/]+)/([^/]+)/(.+)$|) {
6717 my $initiator_name = get_initiator_name
();
6719 return "file.driver=iscsi,file.transport=tcp,file.initiator-name=$initiator_name,".
6720 "file.portal=$portal,file.target=$target,file.lun=$lun,driver=raw";
6723 die "cannot convert iscsi path '$path', unkown format\n";
6726 sub qemu_img_convert
{
6727 my ($src_volid, $dst_volid, $size, $snapname, $is_zero_initialized) = @_;
6729 my $storecfg = PVE
::Storage
::config
();
6730 my ($src_storeid, $src_volname) = PVE
::Storage
::parse_volume_id
($src_volid, 1);
6731 my ($dst_storeid, $dst_volname) = PVE
::Storage
::parse_volume_id
($dst_volid, 1);
6733 die "destination '$dst_volid' is not a valid volid form qemu-img convert\n" if !$dst_storeid;
6737 my $src_is_iscsi = 0;
6741 PVE
::Storage
::activate_volumes
($storecfg, [$src_volid], $snapname);
6742 my $src_scfg = PVE
::Storage
::storage_config
($storecfg, $src_storeid);
6743 $src_format = qemu_img_format
($src_scfg, $src_volname);
6744 $src_path = PVE
::Storage
::path
($storecfg, $src_volid, $snapname);
6745 $src_is_iscsi = ($src_path =~ m
|^iscsi
://|);
6746 $cachemode = 'none' if $src_scfg->{type
} eq 'zfspool';
6747 } elsif (-f
$src_volid) {
6748 $src_path = $src_volid;
6749 if ($src_path =~ m/\.($PVE::QemuServer::Drive::QEMU_FORMAT_RE)$/) {
6754 die "source '$src_volid' is not a valid volid nor path for qemu-img convert\n" if !$src_path;
6756 my $dst_scfg = PVE
::Storage
::storage_config
($storecfg, $dst_storeid);
6757 my $dst_format = qemu_img_format
($dst_scfg, $dst_volname);
6758 my $dst_path = PVE
::Storage
::path
($storecfg, $dst_volid);
6759 my $dst_is_iscsi = ($dst_path =~ m
|^iscsi
://|);
6762 push @$cmd, '/usr/bin/qemu-img', 'convert', '-p', '-n';
6763 push @$cmd, '-l', "snapshot.name=$snapname"
6764 if $snapname && $src_format && $src_format eq "qcow2";
6765 push @$cmd, '-t', 'none' if $dst_scfg->{type
} eq 'zfspool';
6766 push @$cmd, '-T', $cachemode if defined($cachemode);
6768 if ($src_is_iscsi) {
6769 push @$cmd, '--image-opts';
6770 $src_path = convert_iscsi_path
($src_path);
6771 } elsif ($src_format) {
6772 push @$cmd, '-f', $src_format;
6775 if ($dst_is_iscsi) {
6776 push @$cmd, '--target-image-opts';
6777 $dst_path = convert_iscsi_path
($dst_path);
6779 push @$cmd, '-O', $dst_format;
6782 push @$cmd, $src_path;
6784 if (!$dst_is_iscsi && $is_zero_initialized) {
6785 push @$cmd, "zeroinit:$dst_path";
6787 push @$cmd, $dst_path;
6792 if($line =~ m/\((\S+)\/100\
%\)/){
6794 my $transferred = int($size * $percent / 100);
6795 my $remaining = $size - $transferred;
6797 print "transferred: $transferred bytes remaining: $remaining bytes total: $size bytes progression: $percent %\n";
6802 eval { run_command
($cmd, timeout
=> undef, outfunc
=> $parser); };
6804 die "copy failed: $err" if $err;
6807 sub qemu_img_format
{
6808 my ($scfg, $volname) = @_;
6810 if ($scfg->{path
} && $volname =~ m/\.($PVE::QemuServer::Drive::QEMU_FORMAT_RE)$/) {
6817 sub qemu_drive_mirror
{
6818 my ($vmid, $drive, $dst_volid, $vmiddst, $is_zero_initialized, $jobs, $completion, $qga, $bwlimit, $src_bitmap) = @_;
6820 $jobs = {} if !$jobs;
6824 $jobs->{"drive-$drive"} = {};
6826 if ($dst_volid =~ /^nbd:/) {
6827 $qemu_target = $dst_volid;
6830 my $storecfg = PVE
::Storage
::config
();
6831 my ($dst_storeid, $dst_volname) = PVE
::Storage
::parse_volume_id
($dst_volid);
6833 my $dst_scfg = PVE
::Storage
::storage_config
($storecfg, $dst_storeid);
6835 $format = qemu_img_format
($dst_scfg, $dst_volname);
6837 my $dst_path = PVE
::Storage
::path
($storecfg, $dst_volid);
6839 $qemu_target = $is_zero_initialized ?
"zeroinit:$dst_path" : $dst_path;
6842 my $opts = { timeout
=> 10, device
=> "drive-$drive", mode
=> "existing", sync
=> "full", target
=> $qemu_target };
6843 $opts->{format
} = $format if $format;
6845 if (defined($src_bitmap)) {
6846 $opts->{sync
} = 'incremental';
6847 $opts->{bitmap
} = $src_bitmap;
6848 print "drive mirror re-using dirty bitmap '$src_bitmap'\n";
6851 if (defined($bwlimit)) {
6852 $opts->{speed
} = $bwlimit * 1024;
6853 print "drive mirror is starting for drive-$drive with bandwidth limit: ${bwlimit} KB/s\n";
6855 print "drive mirror is starting for drive-$drive\n";
6858 # if a job already runs for this device we get an error, catch it for cleanup
6859 eval { mon_cmd
($vmid, "drive-mirror", %$opts); };
6861 eval { PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs) };
6863 die "mirroring error: $err\n";
6866 qemu_drive_mirror_monitor
($vmid, $vmiddst, $jobs, $completion, $qga);
6869 # $completion can be either
6870 # 'complete': wait until all jobs are ready, block-job-complete them (default)
6871 # 'cancel': wait until all jobs are ready, block-job-cancel them
6872 # 'skip': wait until all jobs are ready, return with block jobs in ready state
6873 sub qemu_drive_mirror_monitor
{
6874 my ($vmid, $vmiddst, $jobs, $completion, $qga) = @_;
6876 $completion //= 'complete';
6879 my $err_complete = 0;
6882 die "storage migration timed out\n" if $err_complete > 300;
6884 my $stats = mon_cmd
($vmid, "query-block-jobs");
6886 my $running_mirror_jobs = {};
6887 foreach my $stat (@$stats) {
6888 next if $stat->{type
} ne 'mirror';
6889 $running_mirror_jobs->{$stat->{device
}} = $stat;
6892 my $readycounter = 0;
6894 foreach my $job (keys %$jobs) {
6896 if(defined($jobs->{$job}->{complete
}) && !defined($running_mirror_jobs->{$job})) {
6897 print "$job : finished\n";
6898 delete $jobs->{$job};
6902 die "$job: mirroring has been cancelled\n" if !defined($running_mirror_jobs->{$job});
6904 my $busy = $running_mirror_jobs->{$job}->{busy
};
6905 my $ready = $running_mirror_jobs->{$job}->{ready
};
6906 if (my $total = $running_mirror_jobs->{$job}->{len
}) {
6907 my $transferred = $running_mirror_jobs->{$job}->{offset
} || 0;
6908 my $remaining = $total - $transferred;
6909 my $percent = sprintf "%.2f", ($transferred * 100 / $total);
6911 print "$job: transferred: $transferred bytes remaining: $remaining bytes total: $total bytes progression: $percent % busy: $busy ready: $ready \n";
6914 $readycounter++ if $running_mirror_jobs->{$job}->{ready
};
6917 last if scalar(keys %$jobs) == 0;
6919 if ($readycounter == scalar(keys %$jobs)) {
6920 print "all mirroring jobs are ready \n";
6921 last if $completion eq 'skip'; #do the complete later
6923 if ($vmiddst && $vmiddst != $vmid) {
6924 my $agent_running = $qga && qga_check_running
($vmid);
6925 if ($agent_running) {
6926 print "freeze filesystem\n";
6927 eval { mon_cmd
($vmid, "guest-fsfreeze-freeze"); };
6929 print "suspend vm\n";
6930 eval { PVE
::QemuServer
::vm_suspend
($vmid, 1); };
6933 # if we clone a disk for a new target vm, we don't switch the disk
6934 PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs);
6936 if ($agent_running) {
6937 print "unfreeze filesystem\n";
6938 eval { mon_cmd
($vmid, "guest-fsfreeze-thaw"); };
6940 print "resume vm\n";
6941 eval { PVE
::QemuServer
::vm_resume
($vmid, 1, 1); };
6947 foreach my $job (keys %$jobs) {
6948 # try to switch the disk if source and destination are on the same guest
6949 print "$job: Completing block job...\n";
6952 if ($completion eq 'complete') {
6953 $op = 'block-job-complete';
6954 } elsif ($completion eq 'cancel') {
6955 $op = 'block-job-cancel';
6957 die "invalid completion value: $completion\n";
6959 eval { mon_cmd
($vmid, $op, device
=> $job) };
6960 if ($@ =~ m/cannot be completed/) {
6961 print "$job: Block job cannot be completed, try again.\n";
6964 print "$job: Completed successfully.\n";
6965 $jobs->{$job}->{complete
} = 1;
6976 eval { PVE
::QemuServer
::qemu_blockjobs_cancel
($vmid, $jobs) };
6977 die "mirroring error: $err";
6982 sub qemu_blockjobs_cancel
{
6983 my ($vmid, $jobs) = @_;
6985 foreach my $job (keys %$jobs) {
6986 print "$job: Cancelling block job\n";
6987 eval { mon_cmd
($vmid, "block-job-cancel", device
=> $job); };
6988 $jobs->{$job}->{cancel
} = 1;
6992 my $stats = mon_cmd
($vmid, "query-block-jobs");
6994 my $running_jobs = {};
6995 foreach my $stat (@$stats) {
6996 $running_jobs->{$stat->{device
}} = $stat;
6999 foreach my $job (keys %$jobs) {
7001 if (defined($jobs->{$job}->{cancel
}) && !defined($running_jobs->{$job})) {
7002 print "$job: Done.\n";
7003 delete $jobs->{$job};
7007 last if scalar(keys %$jobs) == 0;
7014 my ($storecfg, $vmid, $running, $drivename, $drive, $snapname,
7015 $newvmid, $storage, $format, $full, $newvollist, $jobs, $completion, $qga, $bwlimit, $conf) = @_;
7020 print "create linked clone of drive $drivename ($drive->{file})\n";
7021 $newvolid = PVE
::Storage
::vdisk_clone
($storecfg, $drive->{file
}, $newvmid, $snapname);
7022 push @$newvollist, $newvolid;
7025 my ($storeid, $volname) = PVE
::Storage
::parse_volume_id
($drive->{file
});
7026 $storeid = $storage if $storage;
7028 my $dst_format = resolve_dst_disk_format
($storecfg, $storeid, $volname, $format);
7030 print "create full clone of drive $drivename ($drive->{file})\n";
7033 if (drive_is_cloudinit
($drive)) {
7034 $name = "vm-$newvmid-cloudinit";
7035 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
7036 if ($scfg->{path
}) {
7037 $name .= ".$dst_format";
7040 $size = PVE
::QemuServer
::Cloudinit
::CLOUDINIT_DISK_SIZE
;
7041 } elsif ($drivename eq 'efidisk0') {
7042 $size = get_efivars_size
($conf);
7044 ($size) = PVE
::Storage
::volume_size_info
($storecfg, $drive->{file
}, 10);
7046 $newvolid = PVE
::Storage
::vdisk_alloc
(
7047 $storecfg, $storeid, $newvmid, $dst_format, $name, ($size/1024)
7049 push @$newvollist, $newvolid;
7051 PVE
::Storage
::activate_volumes
($storecfg, [$newvolid]);
7053 if (drive_is_cloudinit
($drive)) {
7054 # when cloning multiple disks (e.g. during clone_vm) it might be the last disk
7055 # if this is the case, we have to complete any block-jobs still there from
7056 # previous drive-mirrors
7057 if (($completion eq 'complete') && (scalar(keys %$jobs) > 0)) {
7058 qemu_drive_mirror_monitor
($vmid, $newvmid, $jobs, $completion, $qga);
7063 my $sparseinit = PVE
::Storage
::volume_has_feature
($storecfg, 'sparseinit', $newvolid);
7064 if (!$running || $snapname) {
7065 # TODO: handle bwlimits
7066 if ($drivename eq 'efidisk0') {
7067 # the relevant data on the efidisk may be smaller than the source
7068 # e.g. on RBD/ZFS, so we use dd to copy only the amount
7069 # that is given by the OVMF_VARS.fd
7070 my $src_path = PVE
::Storage
::path
($storecfg, $drive->{file
});
7071 my $dst_path = PVE
::Storage
::path
($storecfg, $newvolid);
7073 # better for Ceph if block size is not too small, see bug #3324
7076 run_command
(['qemu-img', 'dd', '-n', '-O', $dst_format, "bs=$bs", "osize=$size",
7077 "if=$src_path", "of=$dst_path"]);
7079 qemu_img_convert
($drive->{file
}, $newvolid, $size, $snapname, $sparseinit);
7083 my $kvmver = get_running_qemu_version
($vmid);
7084 if (!min_version
($kvmver, 2, 7)) {
7085 die "drive-mirror with iothread requires qemu version 2.7 or higher\n"
7086 if $drive->{iothread
};
7089 qemu_drive_mirror
($vmid, $drivename, $newvolid, $newvmid, $sparseinit, $jobs,
7090 $completion, $qga, $bwlimit);
7095 my ($size) = eval { PVE
::Storage
::volume_size_info
($storecfg, $newvolid, 10) };
7098 $disk->{format
} = undef;
7099 $disk->{file
} = $newvolid;
7100 $disk->{size
} = $size if defined($size);
7105 sub get_running_qemu_version
{
7107 my $res = mon_cmd
($vmid, "query-version");
7108 return "$res->{qemu}->{major}.$res->{qemu}->{minor}";
7111 sub qemu_use_old_bios_files
{
7112 my ($machine_type) = @_;
7114 return if !$machine_type;
7116 my $use_old_bios_files = undef;
7118 if ($machine_type =~ m/^(\S+)\.pxe$/) {
7120 $use_old_bios_files = 1;
7122 my $version = extract_version
($machine_type, kvm_user_version
());
7123 # Note: kvm version < 2.4 use non-efi pxe files, and have problems when we
7124 # load new efi bios files on migration. So this hack is required to allow
7125 # live migration from qemu-2.2 to qemu-2.4, which is sometimes used when
7126 # updrading from proxmox-ve-3.X to proxmox-ve 4.0
7127 $use_old_bios_files = !min_version
($version, 2, 4);
7130 return ($use_old_bios_files, $machine_type);
7133 sub get_efivars_size
{
7135 my $arch = get_vm_arch
($conf);
7136 my (undef, $ovmf_vars) = get_ovmf_files
($arch);
7137 die "uefi vars image '$ovmf_vars' not found\n" if ! -f
$ovmf_vars;
7138 return -s
$ovmf_vars;
7141 sub update_efidisk_size
{
7144 return if !defined($conf->{efidisk0
});
7146 my $disk = PVE
::QemuServer
::parse_drive
('efidisk0', $conf->{efidisk0
});
7147 $disk->{size
} = get_efivars_size
($conf);
7148 $conf->{efidisk0
} = print_drive
($disk);
7153 sub create_efidisk
($$$$$) {
7154 my ($storecfg, $storeid, $vmid, $fmt, $arch) = @_;
7156 my (undef, $ovmf_vars) = get_ovmf_files
($arch);
7157 die "EFI vars default image not found\n" if ! -f
$ovmf_vars;
7159 my $vars_size_b = -s
$ovmf_vars;
7160 my $vars_size = PVE
::Tools
::convert_size
($vars_size_b, 'b' => 'kb');
7161 my $volid = PVE
::Storage
::vdisk_alloc
($storecfg, $storeid, $vmid, $fmt, undef, $vars_size);
7162 PVE
::Storage
::activate_volumes
($storecfg, [$volid]);
7164 qemu_img_convert
($ovmf_vars, $volid, $vars_size_b, undef, 0);
7165 my ($size) = PVE
::Storage
::volume_size_info
($storecfg, $volid, 3);
7167 return ($volid, $size/1024);
7170 sub vm_iothreads_list
{
7173 my $res = mon_cmd
($vmid, 'query-iothreads');
7176 foreach my $iothread (@$res) {
7177 $iothreads->{ $iothread->{id
} } = $iothread->{"thread-id"};
7184 my ($conf, $drive) = @_;
7188 if (!$conf->{scsihw
} || ($conf->{scsihw
} =~ m/^lsi/)) {
7190 } elsif ($conf->{scsihw
} && ($conf->{scsihw
} eq 'virtio-scsi-single')) {
7196 my $controller = int($drive->{index} / $maxdev);
7197 my $controller_prefix = ($conf->{scsihw
} && $conf->{scsihw
} eq 'virtio-scsi-single')
7201 return ($maxdev, $controller, $controller_prefix);
7204 sub windows_version
{
7207 return 0 if !$ostype;
7211 if($ostype eq 'wxp' || $ostype eq 'w2k3' || $ostype eq 'w2k') {
7213 } elsif($ostype eq 'w2k8' || $ostype eq 'wvista') {
7215 } elsif ($ostype =~ m/^win(\d+)$/) {
7222 sub resolve_dst_disk_format
{
7223 my ($storecfg, $storeid, $src_volname, $format) = @_;
7224 my ($defFormat, $validFormats) = PVE
::Storage
::storage_default_format
($storecfg, $storeid);
7227 # if no target format is specified, use the source disk format as hint
7229 my $scfg = PVE
::Storage
::storage_config
($storecfg, $storeid);
7230 $format = qemu_img_format
($scfg, $src_volname);
7236 # test if requested format is supported - else use default
7237 my $supported = grep { $_ eq $format } @$validFormats;
7238 $format = $defFormat if !$supported;
7242 # NOTE: if this logic changes, please update docs & possibly gui logic
7243 sub find_vmstate_storage
{
7244 my ($conf, $storecfg) = @_;
7246 # first, return storage from conf if set
7247 return $conf->{vmstatestorage
} if $conf->{vmstatestorage
};
7249 my ($target, $shared, $local);
7251 foreach_storage_used_by_vm
($conf, sub {
7253 my $scfg = PVE
::Storage
::storage_config
($storecfg, $sid);
7254 my $dst = $scfg->{shared
} ? \
$shared : \
$local;
7255 $$dst = $sid if !$$dst || $scfg->{path
}; # prefer file based storage
7258 # second, use shared storage where VM has at least one disk
7259 # third, use local storage where VM has at least one disk
7260 # fall back to local storage
7261 $target = $shared // $local // 'local';
7267 my ($uuid, $uuid_str);
7268 UUID
::generate
($uuid);
7269 UUID
::unparse
($uuid, $uuid_str);
7273 sub generate_smbios1_uuid
{
7274 return "uuid=".generate_uuid
();
7280 mon_cmd
($vmid, 'nbd-server-stop');
7283 sub create_reboot_request
{
7285 open(my $fh, '>', "/run/qemu-server/$vmid.reboot")
7286 or die "failed to create reboot trigger file: $!\n";
7290 sub clear_reboot_request
{
7292 my $path = "/run/qemu-server/$vmid.reboot";
7295 $res = unlink($path);
7296 die "could not remove reboot request for $vmid: $!"
7297 if !$res && $! != POSIX
::ENOENT
;
7302 sub bootorder_from_legacy
{
7303 my ($conf, $bootcfg) = @_;
7305 my $boot = $bootcfg->{legacy
} || $boot_fmt->{legacy
}->{default};
7306 my $bootindex_hash = {};
7308 foreach my $o (split(//, $boot)) {
7309 $bootindex_hash->{$o} = $i*100;
7315 PVE
::QemuConfig-
>foreach_volume($conf, sub {
7316 my ($ds, $drive) = @_;
7318 if (drive_is_cdrom
($drive, 1)) {
7319 if ($bootindex_hash->{d
}) {
7320 $bootorder->{$ds} = $bootindex_hash->{d
};
7321 $bootindex_hash->{d
} += 1;
7323 } elsif ($bootindex_hash->{c
}) {
7324 $bootorder->{$ds} = $bootindex_hash->{c
}
7325 if $conf->{bootdisk
} && $conf->{bootdisk
} eq $ds;
7326 $bootindex_hash->{c
} += 1;
7330 if ($bootindex_hash->{n
}) {
7331 for (my $i = 0; $i < $MAX_NETS; $i++) {
7332 my $netname = "net$i";
7333 next if !$conf->{$netname};
7334 $bootorder->{$netname} = $bootindex_hash->{n
};
7335 $bootindex_hash->{n
} += 1;
7342 # Generate default device list for 'boot: order=' property. Matches legacy
7343 # default boot order, but with explicit device names. This is important, since
7344 # the fallback for when neither 'order' nor the old format is specified relies
7345 # on 'bootorder_from_legacy' above, and it would be confusing if this diverges.
7346 sub get_default_bootdevices
{
7352 my $first = PVE
::QemuServer
::Drive
::resolve_first_disk
($conf, 0);
7353 push @ret, $first if $first;
7356 $first = PVE
::QemuServer
::Drive
::resolve_first_disk
($conf, 1);
7357 push @ret, $first if $first;
7360 for (my $i = 0; $i < $MAX_NETS; $i++) {
7361 my $netname = "net$i";
7362 next if !$conf->{$netname};
7363 push @ret, $netname;
7370 sub device_bootorder
{
7373 return bootorder_from_legacy
($conf) if !defined($conf->{boot
});
7375 my $boot = parse_property_string
($boot_fmt, $conf->{boot
});
7378 if (!defined($boot) || $boot->{legacy
}) {
7379 $bootorder = bootorder_from_legacy
($conf, $boot);
7380 } elsif ($boot->{order
}) {
7381 my $i = 100; # start at 100 to allow user to insert devices before us with -args
7382 for my $dev (PVE
::Tools
::split_list
($boot->{order
})) {
7383 $bootorder->{$dev} = $i++;
7390 # bash completion helper
7392 sub complete_backup_archives
{
7393 my ($cmdname, $pname, $cvalue) = @_;
7395 my $cfg = PVE
::Storage
::config
();
7399 if ($cvalue =~ m/^([^:]+):/) {
7403 my $data = PVE
::Storage
::template_list
($cfg, $storeid, 'backup');
7406 foreach my $id (keys %$data) {
7407 foreach my $item (@{$data->{$id}}) {
7408 next if $item->{format
} !~ m/^vma\.(${\PVE::Storage::Plugin::COMPRESSOR_RE})$/;
7409 push @$res, $item->{volid
} if defined($item->{volid
});
7416 my $complete_vmid_full = sub {
7419 my $idlist = vmstatus
();
7423 foreach my $id (keys %$idlist) {
7424 my $d = $idlist->{$id};
7425 if (defined($running)) {
7426 next if $d->{template
};
7427 next if $running && $d->{status
} ne 'running';
7428 next if !$running && $d->{status
} eq 'running';
7437 return &$complete_vmid_full();
7440 sub complete_vmid_stopped
{
7441 return &$complete_vmid_full(0);
7444 sub complete_vmid_running
{
7445 return &$complete_vmid_full(1);
7448 sub complete_storage
{
7450 my $cfg = PVE
::Storage
::config
();
7451 my $ids = $cfg->{ids
};
7454 foreach my $sid (keys %$ids) {
7455 next if !PVE
::Storage
::storage_check_enabled
($cfg, $sid, undef, 1);
7456 next if !$ids->{$sid}->{content
}->{images
};
7463 sub complete_migration_storage
{
7464 my ($cmd, $param, $current_value, $all_args) = @_;
7466 my $targetnode = @$all_args[1];
7468 my $cfg = PVE
::Storage
::config
();
7469 my $ids = $cfg->{ids
};
7472 foreach my $sid (keys %$ids) {
7473 next if !PVE
::Storage
::storage_check_enabled
($cfg, $sid, $targetnode, 1);
7474 next if !$ids->{$sid}->{content
}->{images
};
7483 my $qmpstatus = eval {
7484 PVE
::QemuConfig
::assert_config_exists_on_node
($vmid);
7485 mon_cmd
($vmid, "query-status");
7488 return $qmpstatus && $qmpstatus->{status
} eq "paused";